Review

A Review of Analytical Methods for Codeine Determination

by
Rimadani Pratiwi
1,*,
Eka Noviana
2,
Rizky Fauziati
1,
Daniel Blascke Carrão
3,
Firas Adinda Gandhi
1,
Mutiara Aini Majid
1 and
Febrina Amelia Saputri
1
1
Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Bandung 45363, Indonesia
2
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia
3
Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto 14040-901, Brazil
*
Author to whom correspondence should be addressed.
Molecules 2021, 26(4), 800; https://doi.org/10.3390/molecules26040800
Submission received: 8 December 2020 / Revised: 28 January 2021 / Accepted: 1 February 2021 / Published: 4 February 2021
(This article belongs to the Section Analytical Chemistry)

Abstract

:
Codeine is derived from morphine, an opioid analgesic, and has weaker analgesic and sedative effects than the parent molecule. This weak opioid is commonly used in combination with other drugs for over-the-counter cough relief medication. Due to the psychoactive properties of opioid drugs, the easily obtained codeine often becomes subject to misuse. Codeine misuse has emerged as a concerning public health issue due to its associated adverse effects such as headache, nausea, vomiting, and hemorrhage. Thus, it is very important to develop reliable analytical techniques to detect codeine for both quality control of pharmaceutical formulations and identifying drug misuse in the community. This review aims to provide critical outlooks on analytical methods applicable to the determination of codeine.

1. Introduction

Codeine (3-methylmorphine) is an alkaloid prepared from the methylation of morphine derived from poppy seeds (Papaver somniferum) [1]. It is used to manage mild to moderate pain, including chronic cancer pain, and has antitussive, antistress, and antidiarrheal properties [2,3,4]. In the body, a small amount of codeine is metabolized to form morphine (its active metabolite). Until now, the precise mechanism of action of codeine is not known; however, similar to morphine, codeine can bind to opioid receptors in the brain and induce signaling processes throughout the brain and the rest of the body. Codeine also has a sedative effect which helps reduce the pain sensation [1]. The drug has also been used in combination with acetaminophen or aspirin for more effective pain relief [1].
The chemical structure of codeine is given in Figure 1. It has a benzene ring with heteroatoms bound to the ring which is capable of absorbing light energy in the ultraviolet (UV) range, allowing this compound to be analyzed by UV spectrophotometry [5]. There are various forms of codeine salts and hydrates including codeine phosphate, codeine hydrobromide, codeine N-oxide, codeine monohydrate, codeine phosphate sesquihydrate, codeine hydrochloride, and codeine phosphate hemihydrate [6]. Codeine monohydrate is a codeine base that has colorless crystals and is odorless, slightly soluble in water, and freely soluble in ethanol [7]. Codeine phosphate is often used for pharmaceutical formulations. It is a crystalline powder that is odorless, soluble in water, and slightly soluble in ethanol [7].
As codeine (especially its combination with non-opiate analgesics) can be easily obtained over the counter and has a psychoactive effect, it is often misused. Misuse of opioid analgesics including codeine has become an emerging public health concern due to its associated adverse effects on human health [8]. Reliable methods for detecting codeine in various samples are critical for both quality assurance of the drug within pharmaceutical formulations and identification of potential misuse in the community. Various methods have been reported for qualitative and quantitative analysis of codeine [1,9]. Qualitative or simple yes/no analysis often serves as a rapid test to detect the drug presence. This can be achieved via colorimetric assays which provide easy-to-interpret visual results [10]. Codeine can be quantified optically using spectrophotometric methods due to the presence of the chromophore group [11]. This drug is also electro-active, enabling electrochemical measurements for drug quantification [12]. However, the complexity of the matrices often poses a challenge to codeine detection, and thus rigorous sample preparation and/or coupling with separation techniques may be required to achieve accurate determination of the drug. This review aims to assess various analytical methods for codeine detection in the literature and provide critical outlooks on their advantages/disadvantages for analyzing codeine in different sample types. We selected seminal papers on the topic (regardless of the year of publication) to provide a broad overview on applicable methods, with examples (if applicable) provided by more recent publications (last 10 years). We start by evaluating simple colorimetric approaches for qualitative detection and then present two detection methods often used for codeine quantification: optical/spectrophotometric and electrochemical methods. Hyphenated detection methods with separation techniques including chromatography and electromigration-based separation are reviewed next before we finish with conclusions.

2. Colorimetric Assays

Colorimetric assays offer simple visual readouts and do not require complicated instruments for the analysis [10]. The United Nations International Drug Control Programme recommends several colorimetric assays for codeine detection which include the Marquis, Mecke, nitric acid, and ferric sulfate tests [13]. Froehde’s reagent can also be used to identify morphine and codeine. The Marquis and Mecke reagents give a violet color in the presence of opiates including morphine, codeine, and heroin [14]. The detailed color responses from various colorimetric reagents for opiates are shown in Table 1. Codeine reacts with Lieberman’s reagent, producing a black color; with Mandelin’s reagent, producing a green color; and it produces a violet color in the Marquis test [15]. Codeine is also identified by nitric acid reagent by producing an initial orange color that slowly changes to yellow [13]. Nitric acid and Mandelin’s reagents can be used to differentiate codeine from other opiates due to the noticeably different colors they produce for different opiates. Although these colorimetric methods are simple and rapid, most of the chromogenic reagents give similar color responses in the presence of different opioid drugs, making these techniques lack selectivity [16].
A rapid and selective colorimetric method for the detection of codeine sulfate has been developed using unmodified gold nanoprobes by Lodha et al. [17]. Citrate-stabilized gold nanoparticles (AuNPs) were synthesized and could react with codeine sulfate to produce a green color. The kinetics of AuNPs aggregation in the presence of codeine sulfate were obtained by measuring the absorbance and color intensity at the red, green, and blue channels as well as the total RGB. The results showed that there is a significant change in absorbance intensity from 520 to 582 nm upon increasing the concentration of codeine sulfate [17].
While limitations exist within the discussed colorimetric methods, they are still useful techniques for screening samples in large quantities, especially for those in resource-limited settings. In addition, it is possible to improve selectivity or even embedding specificity into the colorimetric approach by using specific recognition elements such as enzymes, antibodies, aptamers, or molecularly imprinted polymers [18,19,20,21]. However, as the assay complexity may increase with these specific recognition elements integrated, one should consider the cost-to-benefit ratio for the intended assay application.

3. Spectrophotometric Analysis

Ultraviolet/visible (UV/VIS) spectrophotometry is often employed in pharmaceutical analysis due to the simplicity of the measurement and the relatively low cost of the instruments [24]. Despite its simplicity, UV/VIS spectrophotometry is a well-established and powerful technique for analyzing single compounds such as bulk materials of active pharmaceutical ingredients (APIs) or excipients. A large UV/VIS spectra library of APIs is available as a reference to determine the identity and quantity of the analyzed sample [15]. The limitation of this technique, however, is the poor selectivity for detecting drug mixtures as compounds with similar chromophores will have overlapping absorption spectra [5]. To address this issue, derivative spectrophotometry and multivariate analysis have been implemented to resolve the overlapping bands and thus enable simultaneous detection of different drugs [25,26,27]. A list of spectrophotometric methods reported in the literature for codeine quantification is provided in Table 2.
Detection of codeine as a single compound in tablets using UV/VIS spectrophotometry was reported by Diaconu et al. [28]. The tablets were ground and 0.1 M NaOH was used to dissolve the drug. The absorbance of codeine was then measured at 284 nm wavelength. Another example was shown by Gharbavi et al., who measured codeine in water samples [29]. Due to the very dilute concentrations of codeine in the samples, they applied dispersive liquid–liquid microextraction preconcentration. The extracted samples were then measured at 270 nm, obtaining a detection limit of 18 μg/L for codeine.
Derivative spectrophotometry is an excellent technique for extracting both qualitative and quantitative information from spectra composed of unresolved bands [30]. The basic principle of this technique is the utilization of the first- or higher-order derivative of the absorbance spectra based on the wavelengths of the parent zero-order spectra [31]. The determination of the derivative values can be carried out by either graphic measurement, numeric measurement, or the zero-crossing technique [32]. Zero-crossing is a common technique in derivative spectrophotometry where the derivative spectrum crosses the zero point(s) of the y-axis at certain wavelengths. This is different from the numeric or graphic measurement where values determined numerically can be altered, yielding inaccurate results [25]. Edebi et al. used a zero-crossing technique to analyze codeine phosphate and diphenhydramine HCl in a cough mixture with zero-crossing points at 258 and 264 nm for codeine phosphate and diphenhydramine HCl, respectively [26]. Hoang et al. also used a similar technique for the simultaneous determination of paracetamol and codeine phosphate in tablets at zero-crossing points of 263.5 and 218.4 nm for the assay of paracetamol and codeine phosphate, respectively [33]. While spectra derivatization offers selective codeine detection in a drug mixture, the reproducibility of the technique highly depends on instrumental parameters such as the speed of the scan and the slit width and thus different instruments may provide different derivatization results [34]. In addition, there is a limit to the number of overlapped bands that the technique is capable of resolving. To date, only simultaneous detection of up to three compounds has been reported using derivatization spectrophotometry [25].
Multivariate analysis has also been implemented to simultaneously detect drug mixtures spectrophotometrically without separation. Dinç and co-workers analyzed a ternary mixture containing codeine phosphate, acetylsalicylic acid, and caffeine using inverse least-squares (ILS) and principal component regression (PCR) [27]. The ILS and PCR calibrations were constructed using a mixture of the three drugs. Excellent mean recoveries (i.e., 100.2% for ILS and 99.5% for PCR) and relative standard deviation (i.e., 1.23% for ILS and 2.10% for PCR) were obtained for codeine phosphate determination in the ternary mixture. The results of this study were also in agreement with results obtained by high-performance liquid chromatography and capillary electrophoresis.
Complete dissolution of the drug substance within the solvent is critical as the absorbance value is proportional to the concentration of the absorbing species in the dissolved form. In addition, particles from undissolved drugs or pharmaceutical excipients can scatter light and skew the measurements. Thus, the solvent must be selected based on the solubility of the analyzed drug. Dinç et al. dissolved ground tablets containing codeine phosphate, acetylsalicylic acid, and caffeine in 0.1 M HCl [27]. Since codeine and caffeine are weak bases, the acidic solution provides excellent dissolution of the drugs. However, for simultaneous detection of the three drugs, the solubility of acetylsalicylic acid should also be considered as the acidic drug will not dissolve well in an acidic aqueous solution. Duong and Fu used water and ethanol sequentially to dissolve codeine phosphate and paracetamol from ground tablets [33]. The sample was dissolved first in water, followed by a residue wash with ethanol.
Sample pre-treatment is typically needed to extract codeine from complex matrices such as biological samples prior to the analysis. Lotfi et al. developed a solid-phase extraction (SPE) technique using multi-walled carbon nanotubes for codeine analysis in human urine, achieving a detection limit of 0.4 μg/L [35]. Mashhadizadeh and Jafari used a cloud point extraction process with a non-ionic surfactant, Triton X-114, to extract codeine from blood samples [36]. Serum samples were collected from the whole blood and mixed with 1% Triton X-114 in the presence of acetate buffer pH 4.5 and bromothymol blue (BTB). The mixture was then centrifuged and cooled in an ice bath to separate the surfactant-rich phase containing codeine from the aqueous solution. The surfactant-rich phase has a distinguishable blue color due to the formation of an ion-pair complex between codeine and BTB and thus can be easily collected using a syringe pipette. A detection limit of 4.6 ng/mL was reported using this approach. Besides removing interfering species, extraction can also be applied for drug preconcentration, as shown by Gharbavi and coworkers previously via liquid–liquid microextraction. They used chloroform to extract codeine from water samples. The chloroform was then evaporated, and methanol was used to redissolve the drug. This technique provided a detection limit of 18 ng/mL [29].
Spectrophotometric methods are suitable for both analyzing a single drug and a mixture of drug compounds. The methods offer a relatively low-cost and easy implementation due to the wide availability of UV/VIS spectrophotometers in most laboratories. Sensitivity and selectivity are still considered as major limitations of these methods. However, sample extraction or preconcentration steps can be integrated to improve the detection limits, while the selectivity issue can be addressed using derivative spectrophotometry techniques or the application of multivariate data analysis.

4. Electrochemical Detection

The utilization of electrochemistry for detecting codeine in various types of samples has become a growing research interest in the past decades. Electrochemical detection offers improved sensitivity and selectivity over colorimetric detection and UV spectroscopy through the selection of electrode materials, detection schemes, and measurement techniques. Due to the miniaturization of electronic components needed for the measurements, electrochemical detection can also be carried out in the field using a portable instrument [38,39], increasing the applicability of the method for forensic and at-home clinical uses. In addition, electrochemical detection can be conveniently coupled with separation-based techniques such as liquid chromatography and capillary electrophoresis for multi-component analysis [40,41,42,43], and flow injection analysis (FIA) or batch injection analysis (BIA) for sample automation [42,44,45].
Codeine is an electroactive species that can be oxidized via a proposed mechanism shown in Figure 2. Direct detection of codeine via this oxidation reaction has been applied in various methods reported in the literature [44,46,47]. Carbon electrodes such as carbon paste, glassy carbon, and boron-doped diamond (BDD) were mostly used for the detection (Table 3). Compared to metallic electrodes, the wider potential window of the carbon electrodes provides favorable electrochemical activity for many redox species [48], including codeine. This wider potential window is also desirable for the simultaneous determination of multiple analytes. For example, the determination of a mixture of codeine, acetaminophen, and caffeine has been demonstrated by Silva et al. using multi-walled carbon nanotubes (MWCNT) modified with a diamond-like carbon film [49]. The oxidation peaks were at 0.7, 1.2, and 1.5 V vs. Ag/AgCl for acetaminophen, codeine, and caffeine, respectively. In addition, carbon electrodes, especially composite materials, are often used in electrochemistry due to their biocompatibility, low cost, and easy fabrication [50]. While the conductivities of carbon electrodes are lower than those of metallic electrodes, various types of modifiers can be added to improve the electrochemical activity (Table 3). For example, by using carbon paste electrodes (CPEs) modified with Zn2SnO4 and graphene, Bagheri et al. were able to significantly improve the conductivity of electrodes from Rct = 1400 in bare CPEs to only 160 Ω in Zn2SnO4/graphene-CPEs for the simultaneous detection of codeine and morphine [51].
While direct detection is the simplest strategy to quantify codeine, the relatively high potentials (often ≥ 1.0 V vs. Ag/AgCl) [46,49,52] needed for the direct oxidation of the analyte could provoke interference from other substances within the sample matrices. This problem can be overcome by the incorporation of a biorecognition element for the detection. For example, Bauer et al. reported the use of two enzymes: morphine dehydrogenase (MDH) and salicylate hydroxylase (SLH), on a Clark-type oxygen electrode [53]. Codeine was oxidized by MDH with a concomitant reduction of nicotinamide adenine dinucleotide phosphate (NADP+) into NADPH. The NADPH was then re-oxidized by SLH and the oxygen was consumed for the reaction elicited measurable current changes. Despite providing selectivity towards codeine, this approach cannot be used for codeine detection in the presence of related substances, for example, morphine, as MDH also oxidizes morphine. Asturias-Arribas et al. demonstrated two enzyme-based approaches for codeine detection. The first approach was based on the reversible inhibition of acetylcholinesterase (AChE) by codeine [54] and the second one utilized cytochrome P450 2D6 (CYP2D6) to oxidize codeine into morphine [55]. Similar to the previous enzymatic approach, these methods are also not specific towards codeine and thus caution should be taken if other AChE inhibitors or substrates for CYP2D6 are present in the sample matrices. Specific electrochemical detection of codeine has been reported by employing aptamers. For example, Saberian et al. immobilized a 5-hydroxy-1,4-naphthoquinone (Juglone)-labeled aptamer on a gold electrode [56]. Codeine binding to the immobilized aptamer induced a conformation change within the aptamer, which brought the redox label closer to the electrode surface, increasing the intensity of the electrochemical signal. Another aptamer-based sensor was proposed by Huang et al. for label-free detection of codeine [57]. A 37-mer aptamer sequence that had been optimized via the truncation–mutation assay was immobilized on a Au-mesoporous silica nanoparticle-modified glassy carbon electrode. The binding of codeine to the aptamer increased the electron transfer resistance and therefore reduced the measured signal. By combining the aptamer-based sensor with differential pulse voltammetry (DPV), a remarkably low detection limit (i.e., 3 pM) was achieved for codeine detection.
Amperometry is often applied for the detection of codeine in a flow-based system. Both single-potential and pulse amperometry have been coupled with either FIA or BIA for automated codeine determination [42,58,59]. Multiple-pulse amperometry (MPA) applies different pulses of potential sequentially and continuously to the working electrode as a function of time, which allows for both analyte detection and electrode cleaning between consecutive measurements. Compared to the commonly applied single-potential amperometry, MPA offers higher sensitivity, a lower detection limit from the negligible capacitive current, and less fouling to the electrodes [58,59]. Pulse voltammetric techniques such as DPV and square-wave voltammetry (SWV) are often used to improve detection limits for codeine quantification in stationary/quiescent solutions [46,47,57]. These pulse techniques rely on the difference in the rate of the decay of the charging (non-faradaic) and the faradaic currents following a potential step. Since the decay rate of the non-faradaic current is much faster than the faradaic current, the techniques can discriminate the faradaic current from the non-faradaic background. Nanomolar detection limits have been reported for codeine determination using DPV or SWV [51,60,61].
The complexity of sample preparation for electrochemical detection of codeine varies depending on the types of matrices. For solid samples such as pharmaceutical tablets, the preparation steps may include sample grinding and homogenization, followed by analyte dissolution into a suitable buffer or supporting electrolyte [47,52,55]. Undissolved materials from the matrices are then separated and removed via centrifugation and/or filtration. Centrifugation and filtration can also be applied to liquid samples that may contain undissolved components such as urine and blood serum/plasma to reduce interference from matrices during electrochemical measurements [52]. Direct measurement on diluted urine or serum samples without further separation has also been conducted by employing the standard addition method [47]. While the method minimizes matrix effects that interfere with measurement signals, the need for several spiked samples for analyte determination should be taken into account when choosing the method.
Electrochemical detection is a very versatile approach for codeine quantification. The sensitivity and selectivity of the assay can be tuned by carefully selecting the assay components (including the integration of biological recognition elements, enzymes for signal amplification), electrode materials, and measurement techniques. In addition, electrochemical detection can be performed using miniaturized/hand-held devices, similar to commercial glucometers, opening various possibilities to adapt the method for codeine determination at the point of care.

5. Chromatographic Analysis

Chromatographic analysis is a method of choice for detecting multi-drug components in a sample simultaneously. While spectral derivatization, multivariate analysis, and the use of specific recognition elements for multiplexed optical/electrochemical measurements have been successful to detect binary or ternary mixtures of drugs, none of these can beat chromatographic or separation-based detection techniques in term of the number of analytes they can resolve at the same time. In addition, the separation process allows for analytes stacking/preconcentrating into plugs or bands, which significantly improves the detection limit compared with direct detection methods. Various detectors such as optical detectors and mass spectrometry (MS) have been coupled to chromatographic systems to identify and quantify analytes. Table 4 provides a list of chromatographic methods that have been applied to codeine analysis.

5.1. Gas Chromatography-Mass Spectrometry (GC-MS)

Gas chromatography (GC) is a separation technique for volatile or semi-volatile constituents in the gas phase. GC can separate a mixture of compounds into individual components where each component can be detected by a detector. Nowadays, mass spectrometer is the most commonly used detector for GC [68], due to its applicability to detect various drug analytes based on their mass-to-charge ratio (m/z). GC-mass spectrometry (GC-MS) is sensitive and leads to definitive identification of codeine based on its characteristic MS fragmentation patterns [69]. This system offers high sensitivity for the detection and quantification of codeine, resulting in an LOD and LOQ in ng/mL [70,71].
Analysis using GC requires relatively complex derivatization steps. As the method can only work with volatile and thermally stable compounds, derivatizations are often needed to make analytes more GC-amenable. For example, N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) is frequently used to derivatize labile groups such as hydroxyl on the target analytes with the more stable trimethylsilyl group [72]. A combination of BSTFA and 1% trimethylchlorosilane (TMCS) was reported by Rana et al. for derivatizing codeine, morphine, hydrocodone, and hydromorphone [71].
Lin et al. derivatized codeine and morphine with N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) prior to sample injection to the GC system [73]. Before derivatization, they also performed acid/enzyme hydrolysis and solid-phase extraction of the drugs from urine samples. Another study reported extraction from urine samples using ethyl acetate, followed by derivatization with propionic anhydride [70]. A study by Kushnir et al. showed that GC derivatization using propionic anhydride provides more accurate and sensitive determination of analytes, compared with derivatizations using BSTFA, N-methyl-bis(trifluoroacetamide) (MBTFA), or heptafluorobutyric acid anhydride (HFAA) [74].
Besides urine samples, GC-MS has also been employed to analyze codeine in sweat. Sweat testing is less invasive than testing with blood or urine and therefore is more desirable for monitoring drug exposure in patients. For instance, Huestis et al. collected sweat specimens from patients using a sweat patch, and then drugs were extracted from the patch with sodium acetate buffer pH 4.0, followed by solid-phase extraction [75]. Extracts were later derivatized using BSTFA and 1% TMCS and analyzed by GC-MS simultaneously for determination of cocaine, codeine, and their metabolites.

5.2. High-Performance Liquid Chromatography (HPLC)

High-performance liquid chromatography (HPLC) is routinely used in laboratories for drug quantification in pharmaceutical dosage forms and clinical samples. Compared to GC, HPLC can accommodate a wider array of analytes including those that are non-volatile and thermally labile. Thus, complicated analyte derivatization steps are not necessary for HPLC analysis. HPLC has been reported to simultaneously detect several opioid drugs with similar structures such as heroin, morphine, and codeine in the sample due to its ability to separate the drugs [73]. Various detectors have been coupled with HPLC including optical detectors (e.g., photomultiplier tube (PMT) and photodiode array (PDA)) [76,77] and mass spectrometry (MS) [78,79,80,81,82].
The selection of stationary/mobile phase and separation conditions in HPLC highly depends on the physicochemical properties of the analytes and the complexity of the analyzed mixture [69]. Reversed-phase HPLC (RP-HPLC) systems with C-18 or C-8 columns have been reported for the determination of codeine/codeine phosphate and other pharmaceutical active ingredients in dosage forms [83,84,85]. In addition, these systems have also been used to detect codeine and its active metabolites in biological samples [86,87]. C-18 columns are popular in RP-HPLC systems due to their relatively high organic/carbon contents, allowing for better interaction between the organic solutes/analytes with the stationary phase [88]. These columns are also more stable at very low or very high pHs compared with columns with shorter alkyl chains [89,90].
Isocratic elution using a mixture of buffered solution and water-miscible organic solvents is often used for the determination of codeine in combination with other drugs. For example, Somsmorn et al. [76] performed isocratic elution for quantitative analysis of codeine and caffeine in a kratom (Mitragyna speciosa Korth.) cocktail. The mobile phase (0.01 M KH2PO4/methanol/acetonitrile/isopropanol (74:8:9:9, v/v/v/v)) was flowed at 1.0 mL/min in an Eclipse XDB-C8 column, resulting in a baseline separation (Rs = 1.5) of codeine and caffeine within 5 min. Prior to the chromatographic analysis, the kratom cocktail was concentrated by a vacuum freeze drier, followed by reconstitution of the dried sample in the mobile-phase solvents. For analysis in pharmaceutical dosage forms, samples are typically diluted with the eluents (for liquid formulations) or dissolved in the eluents followed by filtration to remove undissolved matters (for solid formulations). For instance, Maslarska et al. used an eluent mixture of acetonitrile and buffered solution (pH = 2.5) at 15:85 to dissolve codeine and paracetamol from tablet samples [83]. In addition to the isocratic elution, a gradient in eluent composition can be implemented to maximize analyte separation while keeping the analysis time to a minimum. For example, Hood and Cheung used a gradient combination of mobile phase A (methanol/glacial acetic acid/triethylamine (980:15:6 v/v)) and mobile phase B (water/glacial acetic acid/triethylamine (980:15:6 v/v)) for the simultaneous analysis of codeine phosphate, ephedrine HCl, and chlorpheniramine maleate in a cough–cold syrup formulation [91]. The elution was achieved in less than 7 min at a 1.5 mL/min flow rate.
Besides the conventional aqueous organic mixtures, micellar media can also be used as alternative eluents in RP-HPLC. This approach is often referred to as micellar liquid chromatography (MLC). In addition to their ability to facilitate separation of compounds with a wide range of polarities, micellar media are greener alternatives since they involve a lower quantity of organic modifiers and generate less toxic waste in comparison with the conventional organic eluents [92]. Belal et al. demonstrated MLC for the determination of paracetamol, caffeine, and codeine in tablets and human plasma [87]. They also assessed three different columns: C8, C18, and cyano columns, for the drug separation. Separation in the C8 column resulted in low resolution between caffeine and paracetamol, while the C18 column yielded long retention to codeine (i.e., 16.8 min retention time). The best system was obtained using the cyano column where the three analytes could be well resolved within 5 min.
HPLC with tandem MS or LC-MS/MS has also been increasingly popular in drug analysis. Several excellent review articles on LC-MS/MS applications for drug determination in clinical analysis and drug discovery have been published [93,94,95]. Thus, interested readers are encouraged to refer to these reviews for additional references. LC-MS/MS has recently become a gold standard for benzodiazepine determination [78] and many other drugs including codeine have been successfully quantified using this method. LC-MS/MS offers improved accuracy and precision and wide applicability to various analytes due to the universal nature of the MS detector. Hu et al. reported LC/MS-MS combined with liquid–liquid extraction for the simultaneous determination of codeine, ephedrine, guaiphenesin, and chlorpheniramine in beagle dog plasma, achieving a limit of quantification of 0.08 ng/mL [79]. Another sample preparation for LC/MS-MS analysis was reported using solid-phase extraction to extract codeine, morphine, 6-acetylmorphine, hydrocodone, hydromorphone, oxycodone, and oxymorphone from neat oral fluid [80]. Furthermore, Sproll et al. used a cold extraction method using methanol containing 0.1% acetic acid to extract opiate alkaloids from poppy seeds [81].
LC-MS/MS has emerged as the method of choice for drug abuse screening [96,97,98]. Mass spectra from MS analysis can be compared to a large database of reference drug spectra, allowing identification of the abused drugs [98]. Hei-Hwa Lee et al. successfully identified benzodiazepines and some new psychoactive substances in urine by LC/MS-MS via multiple reaction monitoring [99]. The samples were diluted in bicarbonate buffer pH 9.5, extracted with ethyl acetate, passed through a 0.22-μm polyvinylidene difluoride filter, and then injected into an ACE5 C18 column and eluted with a gradient of an acetonitrile/formic acid mixture. The retention time of codeine was 7.2 min and the Q1 mass was found at 300.1 m/z. Meanwhile, I-Lin Tsai et al. reported an ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) method for screening 62 abused drugs and their metabolites in urine [100]. The samples were diluted 5-fold in deionized water, and then injected into a superficially porous micro-particulate C18 column and eluted with an acetic acid-based mobile phase. The retention time of codeine was 4.35 min with the parent ion found at 300.1 m/z.
HPLC offers various advantages for detecting codeine in drug combinations including selectivity, sensitivity, and wide applicability to various drugs (especially with an MS universal detector). The automation in HPLC analysis also greatly improves the reproducibility of the analysis and the ability to handle a large number of samples. Thus, this method is particularly of interest for routine analysis in pharmaceutical industries and clinical laboratories. The drawback of the method, however, is the high cost and relatively large size of the instrumentations, making HPLC not well-suited for applications in the field or at the point of care.

6. Capillary Electromigration Techniques

Capillary electromigration techniques (CETs), such as capillary electrophoresis (CE), have been used for the analysis of drugs of abuse and their metabolites [101]. CETs are separation techniques based on the resolution of analytes through differences in their migration mobility inside a capillary under the influence of an electric field [102]. Besides CE, other CETs such as non-aqueous capillary electrophoresis (NACE), micellar electrokinetic chromatography (MEKC), capillary electrochromatography (CEC), microemulsion electrokinetic chromatography (MEEKC), and capillary isotachophoresis (CITP) have been successfully employed for the analysis of drugs of abuse [101,103]. CETs are analytical tools that offer as main advantages high efficiency and resolution power, low reagent volumes, and sample consumption as well as lower costs (compared to chromatographic techniques), compatibility with several detection techniques, and automation [104]. The main limitation of CETs is their low sensitivity (mostly using UV/VIS detection), which is associated with the injection of low volumes of samples. However, several injection strategies have been used to enhance sensitivity and overcome this drawback [105,106].
Codeine (Figure 1) is a basic compound with a pKa value of 8.2 [11]. There are several methods in the literature reporting the analysis of codeine employing CETs (Table 5). In recent years, CE has been the main mode used for the determination of codeine using CETs [42,59,107,108,109,110,111,112,113,114,115,116,117,118,119,120]. Ciura et al. (2017) developed a CE analytical method for the analysis of codeine, arecoline, and papaverine, using 160 mM Tris and 200 mM phosphoric acid at pH 2.5 as the background electrolyte (BGE) and a separation potential of 30 kV. The authors evaluated sample injection precision and sensitivity with several injection modes. The obtained results were similar to those from HPLC analysis [115]. NACE and MEKC modes have been used as alternatives for the analysis of codeine [121,122,123,124]. Rodríguez et al. (2014) reported a NACE analytical method for the simultaneous analysis of codeine, morphine, imatinib, and its metabolite in urine. NACE is efficient for the analysis of hydrophobic compounds. The separation was performed using 15 mM ammonium acetate and 1% acetic acid in methanol as the BGE. The authors concluded the method was accurate, precise, sensitive, and specific for its application [121]. Anres et al. (2013) developed an MEKC analytical method, with 46 mM aqueous sodium phosphate buffer, pH 2.1/ACN 80:20 v/v containing 70 mM SDS (sodium dodecyl sulfate) as the BGE and a separation potential of -15 kV, for the analysis of codeine and five other compounds in urine. In MEKC, surfactants such as SDS are added to the BGE to form micelles (with opposite charges to the analytes). Field-enhanced sample injection coupled with sweeping and MEKC (FESI-sweep-MECK) was used, which allows the determination of traces of the analytes [124]. Although other CETs such as CEC, MEEKC, and CITP have the potential to be employed for codeine analysis, they have not been used recently and may be explored in the future.
Recently, CET methods have been used for the analysis of codeine in several samples such as pharmaceutical formulations [42,59,114,116], water [108], urine [109,117,119,121,122,123], saliva [120], exhaled breath [113], hair [107,118], liver microsomes [110], and plant extracts [111,112]. Sample preparation techniques are essential for the extraction of the analytes to perform clean-up of the sample and preconcentration of the analytes before analysis by CETs [125]. Liquid–liquid extraction [107,123], solid-phase extraction [121], dispersive micro solid-phase extraction [113], magnetic solid-phase extraction [109], pressurized liquid extraction [118], ultra-sonification extraction [111,112], and protein precipitation [110,120] have already been employed as sample preparation procedures for codeine analysis. Furthermore, in-line sample techniques have already been used in analysis employing CETs, in-line solid-phase extraction capillary electrophoresis (SPE-CE) [108,118,119], and in-line magnetic solid-phase extraction capillary electrophoresis (MSPE-CE) [117], which increases the possibility of automation of the method. Botello et al. (2012) employed an in-line solid-phase extraction of drugs of abuse, including codeine, for determination in water samples. The SPE extraction was performed using a small segment of the capillary filled with Oasis HLB sorbent, which was inserted in the fused silica capillary. The SPE-CE method presented an LOD of 200 ng/mL of codeine with a sensitivity enhancement factor from 2282. The authors reported that the method demonstrated applicability in tap and river water samples, which were directly analyzed without any off-line sample preparation [108].
Besides the determination of codeine, the analysis of its derivatives such as hydrocodeine, acetyl codeine, codeine-6-β-glucuronide, and other illicit drugs can be performed with CETs. Hydrocodeine is a synthetic derivative from codeine that is twice as strong. Botello et al. (2012) reported a CE method for the simultaneous analysis of codeine, hydrocodeine, and other opioids in human urine. The analytical method presented selectively for the analytes, an LOD of 0.20 ng/mL, and an analysis time of 17 min [119]. Acetylcodeine is an impurity found in street heroin, which is metabolized in codeine. Chen et al. (2011) developed a method by the combination of magnetic solid-phase extraction with CE for the monitoring of codeine, acetylcodeine, heroin, and five other illicit drugs in human urine. The reported method proved to be precise (2.8–12.4%), accurate (85.4–109.7%), and selective for the analysis of all analytes in less than 15 min [109]. Codeine-6-β-glucuronide is the major urinary metabolite of codeine in humans. Bonvin et al. (2014) developed a NACE method for the analysis of glucuronide metabolites of illicit drugs, including codeine-6-β-glucuronide, using minimal sample preparation through a “dilute and shoot” approach. This method presented an LOD of 0.5 µg/mL for the glucuronide metabolite of codeine with an analysis time of 15 min [122].
CETs have been coupled to several detectors such as ultraviolet (UV) [108,109,111,120,123], diode array detectors (DAD) [113,114,115,117,118,121,124], capacitively coupled contactless conductivity detectors (C4D) [42,59,116], electrochemiluminescence (ECL) [112], and mass spectrometry (MS) [107,110,119,122] for the analysis of codeine. Most methods used UV and DAD detection, which offers adequate selectivity and acceptable sensitivity in most cases. Cakir et al. (2019) developed a CE method for the analysis of codeine, amphetamine, and morphine in exhaled breath condensate using DAD detection. The separation was performed in a bare, fused silica capillary with 100 mM phosphoric acid/TEA as a background electrolyte (BGE) at pH 2.5 and including 20% (v/v) methanol and a separation potential of 20 kV. The detection was performed at 210 nm and the method proved to be selective and sensitive for its application with a limit of quantification (LOQ) of 30 ng/mL for codeine [113]. C4D is a powerful electrochemical detector that can be used as an alternative for the analysis of non-chromogenic compounds [126]. Cunha et al. (2017) reported a CE method using C4D for the analysis of codeine, orphenadrine, promethazine, scopolamine, tramadol, and paracetamol in pharmaceutical formulations. The authors used 20 mM β-alanine + 4 mM of NaOH + 4 mM NaCl at pH 9.6 as the BGE, which has adequate mobility and pH, allowing the simultaneous determination of cations and anions with this universal detector. The developed method presented an LOD of 15 µM for codeine and an analysis time of 3 min [116]. ECL detection is based on the emission of light from an electrochemical reaction, which increases selectivity and sensitivity [127]. Gao et al. (2006) developed a CE method for the analysis of codeine and other bioactive compounds in plant extracts using ECL detection. For that, the authors employed an ionic liquid (1-ethyl-3-methylimidazolium tetra-fluoroborate (EMImBF4)) in the BGE to perform the analysis. In this method, the LOD for codeine was 0.25 µM [112]. Finally, MS is a powerful detection technique that can be coupled to CETs, overcoming the main drawback of these separation techniques. In recent years, with the advance of CE-MS electrospray (ESI) interfaces, there are in the literature methods with single quadrupole [122], time-of-flight (TOF) [107], and ion trap [119] mass spectrometers for codeine analysis. Gottardo et al. (2012) employed a CE-TOF method for the analysis of drugs of forensic interest, including codeine, in human hair. The authors used as the BGE a non-volatile buffer, 50 mM ammonium phosphate at pH 6.5, and a sheath liquid composed of an isopropanol/water mixture (50:50 v/v) in the ESI interface. The method was successfully employed for the determination of illicit drugs in human hair, with an LOD of 0.002 ng/mg for codeine, which was possible due to the high selectivity and sensitivity of the TOF mass spectrometer [107].
CETs are an excellent alternative for the analysis of codeine, offering several advantages such as high efficiency, low sample and reagent volumes, low cost, several modes, and compatibility with several detectors. Although sensitivity may be a drawback for CETs, the use of mass spectrometry detectors and techniques that enhance the signal may overcome this issue. Therefore, these techniques present a huge potential of being used for the analysis of drugs of abuse, including codeine.

7. Conclusions

Codeine is an opioid analgesic that is usually available through prescriptions or over the counter in combination with other drugs. Reliable analytical techniques are critical for both quality control of the drug in pharmaceutical dosage forms and the detection of potential misuse by patients. While there is no single method that is well-suited for all analytical purposes, methods can be selected based on the required analytical figures of merit and practical considerations. For example, routine analysis of the drug in centralized laboratories will most likely rely on automated, instrumented techniques such as HPLC, GC, and CE with various detectors and direct detection methods coupled to flow injection analysis. These instrumental techniques provide excellent sensitivity, accuracy, and precision which are pivotal for quality control of pharmaceutical formulations and providing accurate diagnostics for patients. While these techniques cannot be easily brought outside the lab for point-of-care and field analysis, simpler techniques such as rapid colorimetric testing would suffice for the job. Challenges, however, still exist in creating simple, yet integrative platforms for analyzing codeine in various sample matrices. These platforms are also ideally capable of detecting multi-components/analytes and thus can provide more information for further analysis using more sophisticated instruments. In addition, continuous efforts for improving sample preparation steps and analytical operations in the instrumental techniques are also necessary to provide a more efficient, economic, and greener analysis of codeine.

Author Contributions

Conceptualization, R.P.; writing—original draft preparation, R.P., F.A.G., M.A.M., R.F., F.A.S., D.B.C., E.N.; writing—review and editing, R.P., E.N. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Directorate of Research and Community Service of Universitas Padjadjaran, through Article Review Grant 2020, Grant number 733/UN6.3.1/LT/2020.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bhandari, M.; Bhandari, A.; Bhandari, A. Recent Updates on Codeine. Pharm. Methods 2011, 2, 3–8. [Google Scholar] [CrossRef]
  2. Tremlett, M.; Anderson, B.J.; Wolf, A. Pro-Con Debate: Is Codeine a Drug That Still Has a Useful Role in Pediatric Practice? Paediatr. Anaesth. 2010, 20, 183–194. [Google Scholar] [CrossRef]
  3. Szabó, B.; Lakatos, Á.; Kőszegi, T.; Botz, L. HPTLC and HPLC determination of alkaloids in poppies subjected to stress. J. Planar Chromatogr. Mod. TLC 2003, 16, 293–297. [Google Scholar] [CrossRef]
  4. Chary, S.; Goughnour, B.R.; Moulin, D.E.; Thorpe, W.R.; Harsanyi, Z.; Darke, A.C. The dose—Response relationship of controlled-release codeine (Codeine Contin) in chronic cancer pain. J. Pain Symptom Manag. 1994, 9, 363–371. [Google Scholar] [CrossRef]
  5. Farmilo, C.G. The Ultraviolet Spectrophotometric Method. 1954. Available online: https://www.unodc.org/unodc/en/data-and-analysis/bulletin/bulletin_1954-01-01_3_page005.html (accessed on 9 January 2021).
  6. Medsafe. Classification of Codeine: Information Paper for the Medicines Classification Committee; Ministry of Health: Wellington, New Zeland, 2019; pp. 1–24. Available online: https://www.medsafe.govt.nz/profs/class/Agendas/Agen63/MCC63_53a_Reclassificationofcodeine.pdf (accessed on 28 August 2020).
  7. WHO. International Pharmacopeia. 2019. Available online: https://apps.who.int/phint/en/p/docf/ (accessed on 9 November 2020).
  8. Atluri, S.; Sudarshan, G.; Manchikanti, L. Assessment of the trends in medical use and misuse of opioid analgesics from 2004 to 2011. Pain Physician 2014, 17, 119–128. [Google Scholar]
  9. Wu, X.; Zhang, W.; Bai, Y.; Guo, T.; Gu, J. Simultaneous analysis of codeine and its active metabolites in human plasma using liquid chromatography–tandem mass spectrometry: Application to a pharmacokinetic study after oral administration of codeine. J. Pharm. Biomed. Anal. 2013, 78–79, 261–268. [Google Scholar] [CrossRef]
  10. Sriram, G.; Bhat, M.P.; Patil, P.; Uthappa, U.T.; Jung, H.-Y.; Altalhi, T.; Kumeria, T.; Aminabhavi, T.; Pai, R.K.; Madhuprasad; et al. Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review. TrAC Trends Anal. Chem. 2017, 93, 212–227. [Google Scholar] [CrossRef]
  11. PubChem. Codeine. Available online: https://pubchem.ncbi.nlm.nih.gov/compound/Codeine (accessed on 9 January 2021).
  12. Pournaghi-Azar, M.H.; Saadatirad, A. Simultaneous voltammetric and amperometric determination of morphine and codeine using a chemically modified-palladized aluminum electrode. J. Electroanal. Chem. 2008, 624, 293–298. [Google Scholar] [CrossRef]
  13. UNODC. Rapid Testing Methods of Drugs of Abuse; United Nation: New York, NY, USA, 1994. [Google Scholar]
  14. Feldstein, M.; Klendshoj, N.C.; Sprague, A. 2-Anthraquinone Sulfonate Derivatives of Morphine and Codeine. Anal. Chem. 1949, 21, 1580–1581. [Google Scholar] [CrossRef]
  15. Moffat, A.C.; Osselton, M.D.; Widdop, B. Clarke’s Analysis of Drugs and Poisons in Pharmaceuticals, Body Fluids and Postmortem Material; Pharmaceutical Press: London, UK, 2011. [Google Scholar]
  16. Sharma, N.; Barstis, T.; Giri, B. Advances in paper-analytical methods for pharmaceutical analysis. Eur. J. Pharm. Sci. 2018, 111, 46–56. [Google Scholar] [CrossRef]
  17. Lodha, A.; Pandya, A.; Sutariya, P.G.; Menon, S. A smart and rapid colorimetric method for the detection of codeine sulphate, using unmodified gold nanoprobe. RSC Adv. 2014, 4, 50443–50448. [Google Scholar] [CrossRef]
  18. Li, F.; You, M.; Li, S.; Hu, J.; Liu, C.; Gong, Y.; Yang, H.; Xu, F. Paper-based point-of-care immunoassays: Recent advances and emerging trends. Biotechnol. Adv. 2020, 39, 107442. [Google Scholar] [CrossRef]
  19. Bogaart, E.V.D.; Schoone, G.J.; England, P.; Faber, D.; Orrling, K.M.; Dujardin, J.-C.; Sundar, S.; Schallig, H.D.F.H.; Adams, E.R. Simple Colorimetric Trypanothione Reductase-Based Assay for High-Throughput Screening of Drugs against Leishmania Intracellular Amastigotes. Antimicrob. Agents Chemother. 2013, 58, 527–535. [Google Scholar] [CrossRef] [Green Version]
  20. Wang, Z.; Zhang, J.; Liu, L.; Wu, X.; Kuang, H.; Xu, C.; Xu, L. A colorimetric paper-based sensor for toltrazuril and its metabolites in feed, chicken, and egg samples. Food Chem. 2019, 276, 707–713. [Google Scholar] [CrossRef] [PubMed]
  21. Chen, C.-A.; Wang, P.-W.; Yen, Y.-C.; Lin, H.-L.; Fan, Y.-C.; Wu, S.-M.; Chen, C.-F. Fast analysis of ketamine using a colorimetric immunosorbent assay on a paper-based analytical device. Sens. Actuators B Chem. 2019, 282, 251–258. [Google Scholar] [CrossRef]
  22. Schieser, D.W. Free Radicals in Alkaloidal Color Identification Tests. J. Pharm. Sci. 1964, 53, 909–913. [Google Scholar] [CrossRef]
  23. O’Neal, C.L.; Crouch, D.J.; Fatah, A.A. Validation of twelve chemical spot tests for the detection of drugs of abuse. Forensic Sci. Int. 2000, 109, 189–201. [Google Scholar] [CrossRef]
  24. Ahmed, S.; Rasul, A.; Masood, Z. Spectrophotometry in Pharmaceutical Analysis: Determination of Cefaclor in Formulations; LAP Lambert Academic Publishing: Saarbücken, Germany, 2011. [Google Scholar]
  25. Redasani, V.K.; Patel, P.R.; Marathe, D.Y.; Chaudhari, S.R.; Shirkhedkar, A.A.; Surana, S.J. A review on derivative uv-spectrophotometry analysis of drugs in pharmaceutical formulations and biological samples review. J. Chil. Chem. Soc. 2018, 63, 4126–4134. [Google Scholar] [CrossRef]
  26. Edebi, V.; Ebeshi, B.; Anganabiri, E. Simultaneous Assay of Codeine Phosphate and Diphenhydramine Hydrochloride in Cough Mixtures by Zero-Order Derivative UV Spectrophotometry. Afr. J. Pure Appl. Chem. 2011, 5, 104–110. [Google Scholar]
  27. Dinç, E.; Baleanu, D.; Onur, F. Simultaneous spectrophotometric analysis of codeine phosphate, acetylsalicylic acid and caffeine in tablets by inverse least-squares and principal component regression techniques. Anal. Lett. 2002, 35, 545–558. [Google Scholar] [CrossRef]
  28. Diaconu, I.; Aboul-Enein, H.Y.; Bunaciu, A.A.; Tănase, I.G. Estimation of Uncertainty for Measuring Codeine Phosphate Tablets Formulation Using UV-Vis Spectrophotometry. Anal. Lett. 2010, 43, 1207–1216. [Google Scholar] [CrossRef]
  29. Gharbavi, M.; Sereshti, H. Optimized Of Dispersive Liquid-Liquid Micro Extraction and UV- Vis Spectrophotometer for Determination of Codeine in Waters. J. Curr. Res. Sci. 2014, 2, 570–574. [Google Scholar]
  30. Rojas, F.S.; Ojeda Bosch, C.; Cano Pavon, J.M. Derivative Ultraviolet-Visible Region Absorption Spectrophotometry and Its Analytical Applications. Talanta 1988, 35, 753–761. [Google Scholar] [CrossRef]
  31. Ojeda, C.B.; Rojas, F.S.; Rojas, M.F.S. Recent developments in derivative ultraviolet/visible absorption spectrophotometry. Anal. Chim. Acta 2004, 518, 1–24. [Google Scholar] [CrossRef]
  32. Kuś, S.; Marczenko, Z.; Obarski, N. Derivative UV-VIS Spectrophotometry in Analytical Chemistry. Chem. Anal. 1996, 41, 899–929. [Google Scholar]
  33. An, D.T.T.; Hoang, V.D. Simultaneous Determination of Paracetamol and Codeine Phosphate in Combined Tablets by First-Order Derivative and Ratio Spectra First-Order Derivative UV Spectrophotometry. Asian J. Res. Chem. 2009, 2, 143–147. [Google Scholar]
  34. Karpiska, J. Derivative spectrophotometry?recent applications and directions of developments. Talanta 2004, 64, 801–822. [Google Scholar] [CrossRef] [PubMed]
  35. Lotfi, A.; Karimi, S.; Hassanzadeh, J. Preconcentration of codeine in pharmaceutical and human urine samples by multi-walled carbon nanotubes and its spectrophotometric determination. Can. J. Chem. 2016, 94, 857–864. [Google Scholar] [CrossRef]
  36. Mashhadizadeh, M.H.; Jafari, L. Cloud point extraction and spectrophotometric determination of codeine in pharmaceutical and biological samples. J. Iran. Chem. Soc. 2010, 7, 678–684. [Google Scholar] [CrossRef]
  37. Al-Anbakey, A.M.; Qasim, N. Simultaneous Spectrophotometric Determination of Paracetamol and Codeine. Eur. J. Pharm. Med. Res. 2018, 5, 11–15. [Google Scholar]
  38. Freitas, J.M.; Ramos, D.L.; Sousa, R.M.; Paixão, T.R.; Santana, M.H.; Muñoz, R.A.; Richter, E.M. A portable electrochemical method for cocaine quantification and rapid screening of common adulterants in seized samples. Sens. Actuators B Chem. 2017, 243, 557–565. [Google Scholar] [CrossRef]
  39. Balbino, A.; Oiye, M.; Érica, N.; Ribeiro, M.F.M.; Cruz, J.W., Jr.; Eleotério, I.C.; Ipólito, A.J.; de Oliveira, M.F. Use of screen-printed electrodes for quantification of cocaine and Δ9-THC: Adaptions to portable systems for forensic purposes. J. Solid State Electrochem. 2016, 20, 2435–2443. [Google Scholar] [CrossRef]
  40. He, H.; Shay, S.D.; Caraco, Y.; Wood, M.; Wood, A.J. Simultaneous determination of codeine and it seven metabolites in plasma and urine by high-performance liquid chromatography with ultraviolet and electrochemical detection. J. Chromatogr. B Biomed. Sci. Appl. 1998, 708, 185–193. [Google Scholar] [CrossRef]
  41. Gerostamoulos, J.; Crump, K.; McIntyre, I.M.; Drummer, O.H. Simultaneous determination of 6-monoacetylmorphine, morphine and codeine in urine using high-performance liquid chromatography with combined ultraviolet and electrochemical detection. J. Chromatogr. B Biomed. Sci. Appl. 1993, 617, 152–156. [Google Scholar] [CrossRef]
  42. Gimenes, D.T.; Cunha, R.R.; Ribeiro, M.M.A.D.C.; Pereira, P.F.; Munoz, R.A.; Richter, E.M. Two new electrochemical methods for fast and simultaneous determination of codeine and diclofenac. Talanta 2013, 116, 1026–1032. [Google Scholar] [CrossRef] [PubMed]
  43. Zhou, T.; Yu, H.; Hu, Q.; Fang, Y. Determination of codeine and its metabolite in human urine by CE with amperometric detection. J. Pharm. Biomed. Anal. 2002, 30, 13–19. [Google Scholar] [CrossRef]
  44. Shih, Y.; Zen, J.-M.; Yang, H.-H. Determination of codeine in urine and drug formulations using a clay-modified screen-printed carbon electrode. J. Pharm. Biomed. Anal. 2002, 29, 827–833. [Google Scholar] [CrossRef]
  45. Garrido, J.; Delerue-Matos, C.; Borges, F.; Macedo, T.R.A.; Oliveira-Brett, A.M. Electroanalytical determination of codeine in pharmaceutical preparations. Anal. Lett. 2002, 35, 2487–2498. [Google Scholar] [CrossRef] [Green Version]
  46. Simioni, N.B.; Oliveira, G.G.; Vicentini, F.C.; Lanza, M.R.; Janegitz, B.C.; Fatibello-Filho, O. Nanodiamonds stabilized in dihexadecyl phosphate film for electrochemical study and quantification of codeine in biological and pharmaceutical samples. Diam. Relat. Mater. 2017, 74, 191–196. [Google Scholar] [CrossRef]
  47. Švorc, L.; Sochr, J.; Svítková, J.; Rievaj, M.; Bustin, D. Rapid and sensitive electrochemical determination of codeine in pharmaceutical formulations and human urine using a boron-doped diamond film electrode. Electrochim. Acta 2013, 87, 503–510. [Google Scholar] [CrossRef]
  48. MacPherson, J.V. A practical guide to using boron doped diamond in electrochemical research. Phys. Chem. Chem. Phys. 2015, 17, 2935–2949. [Google Scholar] [CrossRef]
  49. Silva, T.A.; Zanin, H.; Corat, E.J.; Fatibello-Filho, O. Simultaneous Voltammetric Determination of Paracetamol, Codeine and Caffeine on Diamond-like Carbon Porous Electrodes. Electroanalysis 2017, 29, 907–916. [Google Scholar] [CrossRef]
  50. McCreery, R.L. Advanced Carbon Electrode Materials for Molecular Electrochemistry. Chem. Rev. 2008, 108, 2646–2687. [Google Scholar] [CrossRef] [PubMed]
  51. Bagheri, H.; Khoshsafar, H.; Afkhami, A.; Amidi, S. Sensitive and simple simultaneous determination of morphine and codeine using a Zn2SnO4nanoparticle/graphene composite modified electrochemical sensor. New J. Chem. 2016, 40, 7102–7112. [Google Scholar] [CrossRef]
  52. Ensafi, A.A.; Ahmadi, N.; Rezaei, B.; Abarghoui, M.M. A new electrochemical sensor for the simultaneous determination of acetaminophen and codeine based on porous silicon/palladium nanostructure. Talanta 2015, 134, 745–753. [Google Scholar] [CrossRef] [PubMed]
  53. Bauer, C.G.; Kühn, A.; Gajovic, N.; Skorobogatko, O.; Holt, P.-J.; Bruce, N.C.; Makower, A.; Lowe, C.R.; Scheller, F.W. New enzyme sensors for morphine and codeine based on morphine dehydrogenase and laccase. Anal. Bioanal. Chem. 1999, 364, 179–183. [Google Scholar] [CrossRef]
  54. Asturias-Arribas, L.; Alonso-Lomillo, M.A.; Domínguez-Renedo, O.; Arcos-Martínez, M.J. Screen-printed biosensor based on the inhibition of the acetylcholinesterase activity for the determination of codeine. Talanta 2013, 111, 8–12. [Google Scholar] [CrossRef]
  55. Asturias-Arribas, L.; Alonso-Lomillo, M.A.; Domínguez-Renedo, O.; Arcos-Martínez, M.J. Cytochrome P450 2D6 based electrochemical sensor for the determination of codeine. Talanta 2014, 129, 315–319. [Google Scholar] [CrossRef]
  56. Saberian, M.; Hamzeiy, H.; Aghanejad, A.; Asgari, D. Aptamer-based Nanosensors: Juglone as an Attached-Redox Molecule for Detection of Small Molecules. BioImpacts 2011, 1, 31–36. [Google Scholar]
  57. Huang, L.; Yang, X.; Qi, C.; Niu, X.; Zhao, C.; Zhao, X.; Shangguan, D.; Yang, Y. A label-free electrochemical biosensor based on a DNA aptamer against codeine. Anal. Chim. Acta 2013, 787, 203–210. [Google Scholar] [CrossRef]
  58. Santos, A.M.; Silva, T.A.; Vicentini, F.C.; Fatibello-Filho, O. Flow injection analysis system with electrochemical detection for the simultaneous determination of nanomolar levels of acetaminophen and codeine. Arab. J. Chem. 2020, 13, 335–345. [Google Scholar] [CrossRef]
  59. Pereira, P.F.; Marra, M.C.; Cunha, R.R.; Da Silva, W.P.; Munoz, R.A.; Richter, E.M. Two simple and fast electrochemical methods for simultaneous determination of promethazine and codeine. J. Electroanal. Chem. 2014, 713, 32–38. [Google Scholar] [CrossRef]
  60. Mashhadizadeh, M.H.; Rasouli, F. Design of a New Carbon Paste Electrode Modified with TiO2 Nanoparticles to Use in an Electrochemical Study of Codeine and Simultaneous Determination of Codeine and Acetaminophen in Human Plasma Serum Samples. Electroanalysis 2014, 26, 2033–2042. [Google Scholar] [CrossRef]
  61. Afkhami, A.; Khoshsafar, H.; Bagheri, H.; Madrakian, T. Facile Simultaneous Electrochemical Determination of Codeine and Acetaminophen in Pharmaceutical Samples and Biological Fluids by Graphene-CoFe2O4 Nancomposite Modified Carbon Paste Electrode. Sens. Actuators B Chem. 2014, 203, 909–918. [Google Scholar] [CrossRef]
  62. Deroco, P.B.; Vicentini, F.C.; Fatibello-Filho, O. An Electrochemical Sensor for the Simultaneous Determination of Paracetamol and Codeine Using a Glassy Carbon Electrode Modified with Nickel Oxide Nanoparticles and Carbon Black. Electroanalysis 2015, 27, 2214–2220. [Google Scholar] [CrossRef]
  63. Santos, A.M.; Vicentini, F.C.; Deroco, P.B.; Rocha-Filho, R.C.; Fatibello-Filho, O. Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode. J. Braz. Chem. Soc. 2015, 26, 2159–2168. [Google Scholar] [CrossRef]
  64. Taei, M.; Hasanpour, F.; Habibollahi, S.; Baghlani, H.; Salavati, H. Simultaneous determination of ascorbic acid, acetaminophen and codeine based on multi-walled carbon nanotubes modified with magnetic nanoparticles paste electrode. Mater. Sci. Eng. C 2016, 69, 1–11. [Google Scholar] [CrossRef]
  65. Ensafi, A.A.; Abarghoui, M.M.; Rezaei, B. Simultaneous determination of morphine and codeine using Pt nanoparticles supported on porous silicon flour modified ionic liquid carbon paste electrode. Sens. Actuators B Chem. 2015, 219, 1–9. [Google Scholar] [CrossRef]
  66. Ensafi, A.A.; Heydari-Bafrooei, E.; Rezaei, B. Different interaction of codeine and morphine with DNA: A concept for simultaneous determination. Biosens. Bioelectron. 2013, 41, 627–633. [Google Scholar] [CrossRef] [PubMed]
  67. Afkhami, A.; Gomar, F.; Madrakian, T. CoFe2O4 nanoparticles modified carbon paste electrode for simultaneous detection of oxycodone and codeine in human plasma and urine. Sens. Actuators B Chem. 2016, 233, 263–271. [Google Scholar] [CrossRef]
  68. Usman, M.; Naseer, A.; Baig, Y.; Jamshaid, T.; Shahwar, M.; Khurshuid, S. Forensic toxicological analysis of hair: A review. Egypt. J. Forensic Sci. 2019, 9, 17. [Google Scholar] [CrossRef]
  69. Dutta, M.; Cai, J.; Gui, W.; Patterson, A.D. A review of analytical platforms for accurate bile acid measurement. Anal. Bioanal. Chem. 2019, 411, 4541–4549. [Google Scholar] [CrossRef]
  70. Zhang, X.; Chen, M.; Cao, G.; Hu, G. Determination of Morphine and Codeine in Human Urine by Gas Chromatography-Mass Spectrometry. J. Anal. Methods Chem. 2013, 2013, 1–6. [Google Scholar] [CrossRef] [Green Version]
  71. Rana, S.; Garg, R.K.; Singla, A. Rapid analysis of urinary opiates using fast gas chromatography–mass spectrometry and hydrogen as a carrier gas. Egypt. J. Forensic Sci. 2014, 4, 100–107. [Google Scholar] [CrossRef] [Green Version]
  72. Orata, F. Derivatization Reactions and Reagents for Gas Chromatography Analysis. In Advanced Gas Chromatography—Progress in Agricultural, Biomedical and Industrial Applications; IntechOpen: Rijeka, Croatia, 2012. [Google Scholar]
  73. Lin, Z.; Lafolie, P.; Beck, O. Evaluation of Analytical Procedures for Urinary Codeine and Morphine Measurements. J. Anal. Toxicol. 1994, 18, 129–133. [Google Scholar] [CrossRef]
  74. Kushnir, M.M.; Crockett, D.K.; Nelson, G.; Urry, F.M. Comparison of four derivatizing reagents for 6-acetylmorphine GC-MS analysis. J. Anal. Toxicol. 1999, 23, 262–269. [Google Scholar] [CrossRef] [Green Version]
  75. Huestis, M.A.; Oyler, J.M.; Cone, E.J.; Wstadik, A.T.; Schoendorfer, D.; Joseph, R.E. Sweat testing for cocaine, codeine and metabolites by gas chromatography-mass spectrometry. J. Chromatogr. B Biomed. Sci. Appl. 1999, 733, 247–264. [Google Scholar] [CrossRef]
  76. Chittrakarn, S.; Penjamras, P.; Keawpradub, N. Quantitative analysis of mitragynine, codeine, caffeine, chlorpheniramine and phenylephrine in a kratom (Mitragyna speciosa Korth.) cocktail using high-performance liquid chromatography. Forensic Sci. Int. 2012, 217, 81–86. [Google Scholar] [CrossRef] [PubMed]
  77. Plotnikov, A.N.; Karpenko, Y.N.; Vikhareva, E.V.; Tyumina, E.A.; Richkova, M.I.; Selyaninov, A.A. Determination of Codeine Phosphate in the Culture Fluid of Rhodococcus by High-Performance Liquid Chromatography. Mosc. Univ. Chem. Bull. 2017, 72, 328–332. [Google Scholar] [CrossRef]
  78. Coles, R.; Kushnir, M.M.; Nelson, G.J.; McMillin, G.A.; Urry, F.M. Simultaneous Determination of Codeine, Morphine, Hydrocodone, Hydromorphone, Oxycodone, and 6-Acetylmorphine in Urine, Serum, Plasma, Whole Blood, and Meconium by LC-MS-MS. J. Anal. Toxicol. 2007, 31, 1–14. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  79. Hu, Z.; Zou, Q.; Tian, J.; Sun, L.; Zhang, Z. Simultaneous determination of codeine, ephedrine, guaiphenesin and chlorpheniramine in beagle dog plasma using high performance liquid chromatography coupled with tandem mass spectrometric detection: Application to a bioequivalence study. J. Chromatogr. B 2011, 879, 3937–3942. [Google Scholar] [CrossRef] [PubMed]
  80. Grabenauer, M.; Moore, K.N.; Bynum, N.D.; White, R.M.; Mitchell, J.M.; Hayes, E.D.; Flegel, R. Development of a Quantitative LC–MS-MS Assay for Codeine, Morphine, 6-Acetylmorphine, Hydrocodone, Hydromorphone, Oxycodone and Oxymorphone in Neat Oral Fluid. J. Anal. Toxicol. 2018, 42, 392–399. [Google Scholar] [CrossRef] [PubMed]
  81. Sproll, C.; Perz, R.; Lachenmeier, D.W. Optimized LC/MS/MS Analysis of Morphine and Codeine in Poppy Seed and Evaluation of Their Fate during Food Processing as a Basis for Risk Analysis. J. Agric. Food Chem. 2006, 54, 5292–5298. [Google Scholar] [CrossRef]
  82. Guo, Q.; Zhang, J.; Zhao, S.; Shao, B. Determination of Five Alkaloids of Pericarpium Papaveris in Hot Pot Broth Using Ultra-Performance Liquid Chromatography Coupled to Triple Quadruple Mass Spectrometry. Food Anal. Methods 2013, 6, 698–704. [Google Scholar] [CrossRef]
  83. Maslarska, V.; Tencheva, J. Simultaneous Determination and Validation of Paracetamol and Codeine Phosphate in Pharmaceutical Preparation by RP-HPLC. Int. J. Pharm. Pharm. Sci. 2013, 5, 417–419. [Google Scholar]
  84. Kommana, R.; Basappa, P. Validated Stability Indicating RP-HPLC Method for Simultaneous Estimation of Codeine Phosphate and Chlorpheniramine Maleate from Their Combined Liquid Dosage Form. Chromatogr. Res. Int. 2013, 2013, 1–7. [Google Scholar] [CrossRef] [Green Version]
  85. Manassra, A.; Khamis, M.; El-Dakiky, M.; Abdel-Qader, Z.; Al-Rimawi, F. Simultaneous HPLC analysis of pseudophedrine hydrochloride, codeine phosphate, and triprolidine hydrochloride in liquid dosage forms. J. Pharm. Biomed. Anal. 2010, 51, 991–993. [Google Scholar] [CrossRef]
  86. Weingarten, B.; Wang, H.-Y.; Roberts, D.M. Determination of codeine in human plasma by high-performance liquid chromatography with fluorescence detection. J. Chromatogr. A 1995, 696, 83–92. [Google Scholar] [CrossRef]
  87. Belal, F.; Omar, M.A.; Derayea, S.; Zayed, S.; Hammad, M.A.; Saleh, S.F. Simultaneous determination of paracetamol, caffeine and codeine in tablets and human plasma by micellar liquid chromatography. Eur. J. Chem. 2015, 6, 468–474. [Google Scholar] [CrossRef]
  88. García-Alvarez-Coque, M.C.; Baeza-Baeza, J.J.; Ramis-Ramos, G. Reversed Phase Liquid Chromatography. In Analytical Separation Science; Wiley-VCH: New York, NY, USA, 2015; pp. 159–198. [Google Scholar]
  89. Hetem, M.J.J.; De Haan, J.W.; Claessens, H.A.; Van De Ven, L.J.M.; Cramers, C.A.; Kinkel, J.N. Influence of alkyl chain length on the stability of n-alkyl-modified reversed phases. 1. Chromatographic and physical analysis. Anal. Chem. 1990, 62, 2288–2296. [Google Scholar] [CrossRef] [Green Version]
  90. Claessens, H.A.; van Straten, M.A. Review on the Chemical and Thermal Stability of Stationary Phases for Reversed-Phase Liquid Chromatography. J. Chromatogr. A 2004, 1060, 23–41. [Google Scholar] [CrossRef]
  91. Hood, D.J.; Cheung, H.-Y. A chromatographic method for rapid and simultaneous analysis of codeine phosphate, ephedrine HCl and chlorpheniramine maleate in cough-cold syrup formulation. J. Pharm. Biomed. Anal. 2003, 30, 1595–1601. [Google Scholar] [CrossRef]
  92. Walash, M.I.; Belal, F.; Tolba, M.M.; Halawa, M.I. Micellar Liquid Chromatography and Derivative Spectrophotometry for the Simultaneous Determination of Acemetacin and Chlorzoxazone in their Tablets and Human Plasma. Sep. Sci. Technol. 2014, 50, 1403–1412. [Google Scholar] [CrossRef]
  93. Korfmacher, W.A. Foundation review: Principles and applications of LC-MS in new drug discovery. Drug Discov. Today 2005, 10, 1357–1367. [Google Scholar] [CrossRef]
  94. Grebe, S.K.G.; Singh, R.J. LC-MS/MS in the Clinical Laboratory—Where to from Here? Clin. Biochem. Rev. 2011, 32, 5–31. [Google Scholar] [PubMed]
  95. Peters, F.T. Recent advances of liquid chromatography–(tandem) mass spectrometry in clinical and forensic toxicology. Clin. Biochem. 2011, 44, 54–65. [Google Scholar] [CrossRef]
  96. Eichhorst, J.C.; Etter, M.L.; Hall, P.L.; Lehotay, D.C. LC-MS/MS Techniques for High-Volume Screening of Drugs of Abuse and Target Drug Quantitation in Urine/Blood Matrices. Adv. Struct. Saf. Stud. 2012, 902, 29–41. [Google Scholar] [CrossRef]
  97. Lee, Y.-W. Simultaneous Screening of 177 Drugs of Abuse in Urine Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry in Drug-intoxicated Patients. Clin. Psychopharmacol. Neurosci. 2013, 11, 158–164. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  98. Mueller, C.A.; Weinmann, W.; Dresen, S.; Schreiber, A.; Gergov, M. Development of a multi-target screening analysis for 301 drugs using a QTrap liquid chromatography/tandem mass spectrometry system and automated library searching. Rapid Commun. Mass Spectrom. 2005, 19, 1332–1338. [Google Scholar] [CrossRef]
  99. Lee, H.-H.; Lee, J.-F.; Lin, S.-Y.; Chen, B.H. Simultaneous identification of abused drugs, benzodiazepines, and new psychoactive substances in urine by liquid chromatography tandem mass spectrometry. Kaohsiung J. Med. Sci. 2016, 32, 118–127. [Google Scholar] [CrossRef] [Green Version]
  100. Tsai, I.-L.; Weng, T.-I.; Tseng, Y.J.; Tan, H.K.-L.; Sun, H.-J.; Kuo, C.-H. Screening and Confirmation of 62 Drugs of Abuse and Metabolites in Urine by Ultra-High-Performance Liquid Chromatography-Quadrupole Time-of-Flight Mass Spectrometry. J. Anal. Toxicol. 2013, 37, 642–651. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  101. Baciu, T.; Botello, I.; Borrull, F.; Calull, M.; Aguilar, C. Capillary electrophoresis and related techniques in the determination of drugs of abuse and their metabolites. TrAC Trends Anal. Chem. 2015, 74, 89–108. [Google Scholar] [CrossRef]
  102. Jorgenson, J.W.; Lukacs, K.D. Zone electrophoresis in open-tubular glass capillaries. Anal. Chem. 1981, 53, 1298–1302. [Google Scholar] [CrossRef]
  103. Sieradzka, E.; Witt, K.; Milnerowicz, H. The application of capillary electrophoresis techniques in toxicological analysis. Biomed. Chromatogr. 2014, 28, 1507–1513. [Google Scholar] [CrossRef]
  104. Keyon, A.S.A.; Miskam, M.; Ishak, N.S.; Mahat, N.A.; Huri, M.A.M.; Wahab, R.A.; Chandren, S.; Razak, F.I.A.; Ng, N.-T.; Ali, T.G.; et al. Capillary electrophoresis for the analysis of antidepressant drugs: A review. J. Sep. Sci. 2019, 42, 906–924. [Google Scholar] [CrossRef]
  105. Breadmore, M.C.; Grochocki, W.; Kalsoom, U.; Alves, M.N.; Phung, S.C.; Rokh, M.T.; Cabot, J.M.; Ghiasvand, A.; Li, F.; Shallan, A.I.; et al. Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2016–2018). Electrophoresis 2019, 40, 17–39. [Google Scholar] [CrossRef] [Green Version]
  106. Hamidi, S. Recent Progresses in Sensitive Determination of Drugs of Abuse by Capillary Electrophoresis. Curr. Anal. Chem. 2020, 16, 369–380. [Google Scholar] [CrossRef]
  107. Gottardo, R.; Mikšík, I.; Aturki, Z.; Sorio, D.; Seri, C.; Fanali, S.; Tagliaro, F. Analysis of drugs of forensic interest with capillary zone electrophoresis/time-of-flight mass spectrometry based on the use of non-volatile buffers. Electrophoresis 2012, 33, 599–606. [Google Scholar] [CrossRef]
  108. Botello, I.; Borrull, F.; Aguilar, C.; Calull, M. Investigation of in-line solid-phase extraction capillary electrophoresis for the analysis of drugs of abuse and their metabolites in water samples. Electrophoresis 2012, 33, 528–535. [Google Scholar] [CrossRef] [PubMed]
  109. Chen, M.; Suo, L.-L.; Gao, Q.; Feng, Y.-Q. Determination of eight illegal drugs in human urine by combination of magnetic solid-phase extraction with capillary zone electrophoresis. Electrophoresis 2011, 32, 2099–2106. [Google Scholar] [CrossRef] [PubMed]
  110. Lu, M.; Li, Q.; Lai, Y.; Zhang, L.; Qiu, B.; Chen, G.; Cai, Z. Determination of stimulants and narcotics as well as their in vitro metabolites by online CE-ESI-MS. Electrophoresis 2011, 32, 472–478. [Google Scholar] [CrossRef]
  111. Fakhari, A.R.; Nojavan, S.; Ebrahimi, S.N.; Evenhuis, C.J. Optimized ultrasound-assisted extraction procedure for the analysis of opium alkaloids in papaver plants by cyclodextrin-modified capillary electrophoresis. J. Sep. Sci. 2010, 33, 2153–2159. [Google Scholar] [CrossRef]
  112. Gao, Y.; Xiang, Q.; Xu, Y.; Tian, Y.; Wang, E. The use of CE-electrochemiluminescence with ionic liquid for the determination of bioactive constituents in Chinese traditional medicine. Electrophoresis 2006, 27, 4842–4848. [Google Scholar] [CrossRef]
  113. Hamidi, S. Simultaneous and Sensitive Determination of Amphetamine, Codeine and Morphine in Exhaled Breath Condensate, Using Capillary Electrophoresis Coupled with On-line and Off-line Enhancing Methods. Curr. Pharm. Anal. 2020, 16, 872–879. [Google Scholar] [CrossRef]
  114. Cakir, K.; Erkmen, C.; Uslu, B.; Goger, N.G. Quantitative determination of paracetamol, caffeine and codeine phosphate in pharmaceutical dosage forms by using capillary electrophoresis method. Rev. Roum. Chim. 2019, 64, 801–808. [Google Scholar] [CrossRef]
  115. Ciura, K.; Pawelec, A.; Buszewska-Forajta, M.; Markuszewski, M.J.; Nowakowska, J.; Prahl, A.; Wielgomas, B.; Dziomba, S. Evaluation of sample injection precision in respect to sensitivity in capillary electrophoresis using various injection modes. J. Sep. Sci. 2017, 40, 1167–1175. [Google Scholar] [CrossRef] [PubMed]
  116. Cunha, R.R.; Ribeiro, M.M.A.C.; Muñoz, R.A.A.; Richter, E.M. Fast determination of codeine, orphenadrine, promethazine, scopolamine, tramadol, and paracetamol in pharmaceutical formulations by capillary electrophoresis. J. Sep. Sci. 2017, 40, 1815–1823. [Google Scholar] [CrossRef] [PubMed]
  117. Baciu, T.; Borrull, F.; Neusüß, C.; Aguilar, C.; Calull, M. Capillary electrophoresis combined in-line with solid-phase extraction using magnetic particles as new adsorbents for the determination of drugs of abuse in human urine. Electrophoresis 2016, 37, 1232–1244. [Google Scholar] [CrossRef]
  118. Baciu, T.; Borrull, F.; Aguilar, C.; Calull, M. Findings in the hair of drug abusers using pressurized liquid extraction and solid-phase extraction coupled in-line with capillary electrophoresis. J. Pharm. Biomed. Anal. 2016, 131, 420–428. [Google Scholar] [CrossRef]
  119. Botello, I.; Borrull, F.; Calull, M.; Aguilar, C.; Somsen, G.W.; De Jong, G.J. In-line solid-phase extraction–capillary electrophoresis coupled with mass spectrometry for determination of drugs of abuse in human urine. Anal. Bioanal. Chem. 2012, 403, 777–784. [Google Scholar] [CrossRef]
  120. Meng, P.; Wang, Y.; Meng, L. PH-Mediated Stacking in Capillary Electrophoresis for Analysis of Opiates in Saliva. Anal. Methods 2012, 4, 3695–3700. [Google Scholar] [CrossRef]
  121. Rodríguez, J.F.; Castañeda, G.; Muñoz, L.; López-Sanz, S. Development and validation of a non-aqueous capillary electrophoresis method for the determination of imatinib, codeine and morphine in human urine. Anal. Methods 2014, 6, 3842. [Google Scholar] [CrossRef]
  122. Bonvin, G.; Schappler, J.; Rudaz, S. Non-aqueous capillary electrophoresis for the analysis of acidic compounds using negative electrospray ionization mass spectrometry. J. Chromatogr. A 2014, 1323, 163–173. [Google Scholar] [CrossRef] [PubMed]
  123. Ho, Y.-H.; Wang, C.-C.; Hsiao, Y.-T.; Ko, W.-K.; Wu, S.-M. Analysis of ten abused drugs in urine by large volume sample stacking–sweeping capillary electrophoresis with an experimental design strategy. J. Chromatogr. A 2013, 1295, 136–141. [Google Scholar] [CrossRef]
  124. Anres, P.; Gareil, P.; Delaunay, N.; Vial, J.; Thormann, W. Influence of high-conductivity buffer composition on field-enhanced sample injection coupled to sweeping in CE. Electrophoresis 2013, 34, 353–362. [Google Scholar] [CrossRef]
  125. Jarvas, G.; Guttman, A.; Miękus, N.; Bączek, T.; Jeong, S.; Chung, D.S.; Pätoprstý, V.; Masár, M.; Hutta, M.; Datinská, V.; et al. Practical Sample Pretreatment Techniques Coupled with Capillary Electrophoresis for Real Samples in Complex Matrices. TrAC Trends Anal. Chem. 2020, 122, 115702. [Google Scholar] [CrossRef]
  126. Elbashir, A.A.; Elgorashe, R.E.E.; Alnajjar, A.O.; Aboul-Enein, H.Y. Application of Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection (CE-C4D): 2017–2020. Crit. Rev. Anal. Chem. 2020, 24, 1–9. [Google Scholar] [CrossRef]
  127. Adcock, J.L.; Conlan, X.A.; Barrow, C.J.; Barnett, N.W.; Hogan, C.F.; Francis, P. Chemiluminescence and electrochemiluminescence detection of controlled drugs. Drug Test. Anal. 2010, 3, 145–160. [Google Scholar] [CrossRef]
Figure 1. Structure of codeine.
Figure 1. Structure of codeine.
Molecules 26 00800 g001
Figure 2. Proposed mechanism for the electro-oxidation of codeine [12].
Figure 2. Proposed mechanism for the electro-oxidation of codeine [12].
Molecules 26 00800 g002
Table 1. Color responses of different chromogenic reagents for detecting codeine, heroin, and morphine.
Table 1. Color responses of different chromogenic reagents for detecting codeine, heroin, and morphine.
CompoundCodeineHeroinMorphineRef.
Marquisvioletvioletviolet[15]
Meckeblue to greenblue to greenblue to green[15,22]
Froehdelight greenn/aviolet to grey[15,23]
Mandelingreen to blueblue-greylight grey[15]
LiebermanBlackn/ablack[15]
Ferric sulfaten/an/ared[13]
Nitric acidorange slowly changing to yellowyellow slowly changing to light greenorange rapidly changing to red then slowly to yellow[13]
AuNPsgreen--[17]
Table 2. Spectrophotometric methods for codeine quantification.
Table 2. Spectrophotometric methods for codeine quantification.
AnalyteMatrixMethodMaximum WavelengthLOD/LOQ% RSD/RecoveryRef.
CodeineTabletUV/VIS spectrophotometry284 nm 0.1 M NaOHNARSD = 0.0003[28]
CodeineWaterUV/VIS spectrophotometry270 nm in methanolLOD = 18 ng/mLRSD = 1.9%
Recovery = 97.2–97.9%
[29]
CodeineHuman urineUV spectrophotometry265 nm in methanolLOD = 0.4 ng/mL
LOQ = 1.3 ng/mL
RSD = 1.56% for 0.01 mg/L[35]
Codeine phosphate, Diphenhydramine HClCough mixtureZero-order derivative UV spectrophotometry258 nm for codeine phosphate; 264 nm for diphenhydramine HCl (in HCl)LOD = 1000 ng/mL
LOQ = 50,000 ng/mL
RSD = 2.64%
Recovery = 96.99–102.4%
[26]
Codeine phosphate, ParacetamolTabletFirst-order derivative UV spectrophotometry263.5 nm for paracetamol; 218.4 nm for codeine phosphate (in ethanol)LOD = 260 ng/mL
LOQ = 870 ng/mL
RSD = 0.36%
Recovery = 99%
[33]
Codeine phosphate, Acetylsalicylic acid, CaffeineTabletSpectrophotometric simultaneous analysis by inverse least-squares (ILS) and principal component regression (PCR) techniques (chemometric)The absorbance values were measured at 15 points in the wavelength range 220–290 nm (in HCl)NARSD = 1.23% for ILS
2.1% for PCR
Recovery = 100.2% for ILS
99.5% for PCR
[27]
CodeineAcetaminophen codeine tablet and bloodUV/VIS spectrophotometry430 nm in ethanolLOD = 4.6 ng/mLRSD = 2.15%.[36]
Codeine, ParacetamolTabletsUV spectrophotometric243 nm for paracetamol; 278 nm for codeine (in H2O:ACN 90:10 v/v)LOD = 50 ng/mL
LOQ = 165 ng/mL
RSD = 0.81%
Recovery = 100.53%
[37]
UV: ultraviolet; UV/VIS: ultraviolet/visible LOD: limit of detection; LOQ: limit of quantification; RSD: relative standard deviation.
Table 3. Various electrochemical methods for codeine determination reported in the past decade.
Table 3. Various electrochemical methods for codeine determination reported in the past decade.
AnalyteMatrixMethodElectrodeLOD% RSD/Recovery Ref.
CodeineTablet and urineChrono-amperometryTetrathiafulvalene/AChE- modified screen-printed carbonLOD = 20,000 nMRSD = 3.3%
Recovery = 102 ± 10% (tablet)
101 ± 11% (urine)
[54]
Tablet and urineChrono-amperometryCYP2D6-modified screen-printed carbonLOD = 4900 nMRSD = 8.9%
Recovery = 105 ± 7% (tablet)
108 ± 13% (urine)
[55]
Tablet, urine, and serumSWVNanodiamond/dihexadecyl phosphate-modified glassy carbonLOD = 54.5 nMRSD = 3.2%
Recovery = 84–95% (tablet)
88-101% (urine)
93-100% (serum)
[46]
Tablet and urineDPVBDDLOD = 80 nMRSD = 5%
Recovery = 95–103% (tablet)
In agreement with HPLC-PDA (urine)
[47]
Standard solutionDPVAu-mesoporous Si NPs/aptamer-modified glassy carbonLOD = 0.003 nM-[57]
Codeine
Acetaminophen
Tablet, urine, and serumAmperometry and DPVPd NPs/porous Si microparticle-modified CNT paste LOD = 200 nM (amperometry)
LOD = 300 nM (DPV)
RSD = 4.9%
Recovery = 97–105% (tablet)
96–104% (urine)
97–99% (serum)
[52]
Tablet, urine and serumMPA with FIACathodically treated BDDLOD = 35 nMRSD = 3–4%
Recovery = In agreement with HPLC (tablet)
102–107% (urine)
98–108% (serum)
[58]
SerumDPVTiO2 NPs-modified carbon pasteLOD = 18 nMRSD = 1.3%
Recovery = 95–100%
[60]
Tablet, urine, and serumSWVNiO NPs/carbon black/DHP-modified glassy carbonLOD = 480 nMRSD = 8.8%
Recovery = In agreement with HPLC (tablet)
98–110% (urine)
97–108% (serum)
[62]
Pharmaceutical formulations, plasma, and urineSWVGraphene/CoFe2O4 NPs-modified carbon pasteLOD = 11 nMRSD = 4%
Recovery = 98 ± 20% (tablet)
99 ± 2% (syrup)
98–102% (urine)
98–102% (plasma)
[61]
Tablet, urine, and serumSWVCathodically treated BDDLOD = 14 nMRSD = 4.2%
Recovery = 76–98% (tablet)
98–100% (urine)
98–106% (serum)
[63]
Codeine
Acetaminophen
Ascorbic acid
Tablet, urine, and serumSWVZnCrFeO4 NPs-modified MWCNT pasteLOD = 10 nMRSD = 2.1%
Recovery = 93–102% (tablet)
94–99% (syrup)
91–102% (urine)
96–102% (serum)
[64]
Codeine
Acetaminophen
Caffeine
Urine and serumSWVDiamond-like carbon film grown on vertically aligned MWCNTLOD = 160 nMRSD = <8%
Recovery = 91–110% (urine)
85–98% (serum)
[49]
Codeine
Morphine
Urine and serumDPVPt NPs/porous Si flour-modified ionic liquid carbon pasteLOD = 20 nMRSD = 5.7%
Recovery = 104–107% (urine)
96–103% (serum)
[65]
Pharmaceutical formulations, urine, and plasmaDPVZn2SnO4 NPs/graphene-modified carbon pasteLOD = 9 nMRSD = 3.2%
Recovery = 99 ± 3% (syrup)
99 ± 3% (injection)
98–101% (urine)
97–104% (plasma)
[51]
Pharmaceutical formulations, urine and plasmaDPVdsDNA/MWCNT/PDDA-modified pencil graphiteLOD = 41 ng/mLRSD = 6.9%
Recovery = 102 ± 9% (syrup)
105 ± 14% (injection)
104 ± 10% (urine)
102 ± 10% (plasma)
[66]
Codeine
Diclofenac
TabletAmperometry with BIABDDLOD = 1000 nMRSD = 0.9%
Recovery = 99–104%
[42]
Codeine
Promethazine
Pharmaceutical formulationMPA with BIABDDLOD = 140 ng/mLRSD = 7.9%
Recovery = 96–98%
[59]
Codeine
Oxycodone
Plasma and urineDPVCoFe2O4 NPs-modified carbon pasteLOD = 20 nMRSD = 0.1%
Recovery = 98–103% (urine)
98–102% (plasma)
[67]
BDD: boron-doped diamond; BIA: batch injection analysis; CNT: carbon nanotubes; DHP: dihexadecylphosphate; DPV: differential pulse voltammetry; FIA: flow injection analysis; LOD: limit of detection; LOQ: limit of quantification; MPA: multiple-pulse amperometry; MWCNT: multi-walled carbon nanotubes; PDDA: poly(diallyldimethylammonium chloride); SWV: square-wave voltammetry.
Table 4. Chromatographic system for codeine determination.
Table 4. Chromatographic system for codeine determination.
AnalyteMatrixMethodElution Type and Mobile Phase/Flow RateColumn/TemperatureDetectorLOD/LOQ% RSD/RecoveryRef.
Morphine
Codeine
Human urineGC-MSHelium as the carrier gas; 1.0 mL/minHP-1MS column; temperature programmingMS-selected ion monitoring (SIM) modeLLOQ = 25 ng/mLRSD = 13%,
Recovery = 87.2–108.5%.
[70]
Morphine
Codeine
Hydrocodone
Hydromorphone
Human urineGC-MSHydrogen as the carrier gas; 1.0 mL/minGC column; temperature programmingMS-electron impact modeLOD = 50 ng/mL
LOQ = 100 ng/mL
RSD = 2.3%
Recovery = 99.97%
[71]
Cocaine
Codeine
Metabolites
SweatGC-MSHelium as the carrier gasHP-1 fused silica capillary column; temperature programmingMS-selected ion monitoring (SIM) modeLOD = 2.5 ng/patch
LOQ = 2.5 ng/patch
RSD = 3.0%
Recovery = 111.1%
[75]
CodeineHuman plasmaRP-HPLCAcetonitrile and 5 mM ammonium phosphate dibasic (8:92, v/v) adjusted to pH 5.8 with phosphoric acid; 1.0 mL/minReversed-phased C8 column; ambient temperatureFluorescenceLOD = 5 ng/mL
LOQ = 10 ng/mL
RSD = 1.35–16.1%
Recovery = 82.7–108%
[86]
Mitragynine
Codeine
Caffeine
Chlorpheniramine
Phenylephrine
Kratom cocktail (Mitragyna speciosa Korth.)RP-HPLCIsocratic elution 0.01 M KH2PO4/methanol/
Acetonitrile/isopropanol (74:8:9:9, v/v/v/v); 1.0 mL/min
Eclipse XDB-C8 column; 25 °C.PDALOD = 5 ng/mL
LOQ = 10 ng/mL
RSD = 2.495%
Recovery = 98.96%
[76]
Codeine phosphate
Chlorpheniramine maleate
Oral syrupRP-HPLCIsocratic elution; 1% o-phosphoric acid in water/acetonitrile/methanol (78:10:12); 1 mL/minPhenomenex C18 column; 23 °CUV/VISLOD = 2263 ng/mL
LOQ = 6859 ng/mL
RSD = 0.23%
Recovery = 99.01%
[84]
Codeine phosphateCulture fluid of RhodococcusRP-HPLCPhosphate buffer (pH 3.0) and acetonitrile (15:85); 1 mL/minC18-modified silica gel; 40 °CPDALOD = 200 ng/mL
LOQ = 500 ng/mL
RSD = 0.35%
Recovery = 97.92%
[77]
Caffeine
Codeine
Paracetamol
Tablets and human plasmaMicellar liquid chromatography140 mM sodium dodecyl sulfate, 25 mM phosphate buffer, and 10% acetonitrile at pH = 3; 1 mL/minCyano column; 35 °CUVLOD = 54 ng/mL
LOQ = 164 ng/mL
RSD = 0.803%
Recovery = 99.51%
[87]
Codeine phosphate
Triprolidine
Hydrochloride
Pseudophedrine hydrochloride
Liquid formulationRP-HPLCMethanol/acetate buffer/acetonitrile (85:5:10, v/v); 1.5 mL/minC18 column UVLOD = 54 ng/mL
LOQ = 164 ng/mL
RSD = 0.6%
Recovery = 99.4%
[85]
Codeine phosphate
Paracetamol
TabletRP-HPLCIsocratic elution; acetonitrile/buffer solution (pH = 2.5) (15:85); 1 mL/minLiChrospher® RP-18 column UV/VISLOD = 60 ng/mL
LOQ = 600 ng/mL
RSD = 0.6%
Recovery = 99.33–100.3%
[83]
Codeine phosphate
Ephedrine HCl
Chlorpheniramine maleate
SyrupRP-HPLCMobile phase A consisted of methanol/glacial acetic acid/triethylamine (980:15:6 v/v) and mobile phase B was water/glacial acetic acid/triethylamine (980:15:6 v/v); 1.5 mL/minZorbax XDB C8 column; 30 °CUV-diode arrayNot evaluatedRSD = 0.08%
Recovery = 99.87–100.96%
[91]
Morphine
Codeine
Thebaine
Papaverine
Noscapine
Pericarpium papaveris (Papaver somniferum L.) in hot pot brothUPLC-QqQ-MSGradient elution; methanol (solvent B) and water (solvent A); 0.3 mL/minAcquity BEH C18 column; 40 °CMS in positive electrospray ionization with multiple reaction monitoring (MRM)LOD = 40 ng/kg
LOQ = 100 ng/kg
RSD = 16.9–20.5%
Recovery = 78.9–124%
[82]
Codeine
Guaiphenesin
Chlorpheniramine
Ephedrine
Beagle dog plasmaLC-MS/MSFormic acid: 10 mM ammonium acetate/methanol (0.2:62:38, v/v); 0.2 mL/minPhenomenex Luna C18 analytical column; MS-selected reaction monitoring (SRM) modeLLOQ = 0.08 ng/mLRSD = 7%
Recovery = 91%
[79]
Codeine
Morphine
6-acetylmorphine
Hydrocodone
Hydromorphone
Oxycodone
Oxymorphone
Neat oral fluidLC-MS/MSMobile phase was initially 95% 5 mM ammonium formate in water with 0.1% formic acid, decreased to 85% over 2 min then 5% over 1.5 min; 0.5 mL/minAgilent Poroshell 120 SB-C18 column; MS-positive electrospray ionization (ESI) modeLOD = 0.04 ng/mL
LLOQ 1.5 ng/mL
RSD = 3.7%
Recovery = 99.3%
[80]
Codeine
Morphine
Hydrocodone
Hydromorphone
Oxycodone
6-Acetylmorphine
Urine, serum, plasma, whole blood, and meconiumLC-MS-MSIsocratic acetonitrile and 2mM ammonium formate buffer at pH 3.0. (15%:85%)0.525 mL/minMS in positive electrospray ionization with multiple reaction monitoring (MRM)LOD = 1
LLOQ = 2
ng/mL in urine, serum/plasma, and whole blood; ng/g in meconium
Recovery = 90.8% in urine and 50.4% in meconium[78]
Morphine
Codeine
Poppy seedLC-MS/MSGradient program; mobile phase A (water, 20 mM ammonium hydrogen carbonate, adjusted with ammonia to pH 9) and mobile phase B (water/methanol 5:95 (v/v), 20 mM ammonium hydrogen carbonate, adjusted with ammonia to pH 9); 0.2 mL/minReversed-phase Phenomenex, RP 18 Gemini column; 40 °CMS-positive electrospray ionization (ESI) modeLOD = 300,000 ng/kgPrecision = 7.4-9.0%
Accuracy = 9.8–17.6%
[81]
GC: gas chromatography; HPLC: high-performance liquid chromatography; LC: liquid chromatography; LOD: limit of detection; LLOQ: lower limits of quantification; LOQ: limit of quantification; MS: mass spectrometry; PDA: photo diode array; QqQ-MS: triple quadruple mass spectrometry; RP: reversed-phase; UPLC: ultra-performance liquid chromatography.
Table 5. Capillary electromigration techniques for analysis of codeine.
Table 5. Capillary electromigration techniques for analysis of codeine.
AnalytesMatrixCETAnalysis ConditionsAnalysis TimeLOD/LOQ% RSD/RecoveryRef.
Amphetamine
Codeine
Morphine
Exhaled breath condensateCE-DADBare fused silica capillary (41.5 cm effective length, 50 µm I.D.)
100 mM phosphoric acid/TEA at pH 2.5 including 20% (v/v) methanol
20 kV, 25 °C
15 minLOQ = 30 ng/mLRSD = 0.60–9.70%
Recovery = −1.70–5.40%
[113]
Paracetamol
Caffeine
Codeine
Pharmaceutical dosage formsCE-DADUncoated fused silica capillary (47.5 cm effective length, 50 μm I.D.)
25 mM Na2HPO4 buffer containing 10% methanol at pH 8.5
27 kV, 25 °C
5 min--[114]
Arecoline
Codeine
Papaverine
StandardCE-DADUncoated fused silica capillary (60 cm total length, 50 μm I.D.)
160 mM Tris and 200 mM phosphoric acid at pH 2.5
30 kV, 25 °C
9 minLOQ = 4 ng/mL-[115]
Codeine
Orphenadrine
Promethazine
Scopolamine
Tramadol
Paracetamol
Pharmaceutical formulationsCE-C4DFused silica capillary (40 cm effective length, 50 µm I.D.)
20 mM β-alanine + 4 mM of NaOH + 4 mM NaCl at pH 9.6
25 kV, 25 °C
3 minLOD = 15,000 nMRecovery = 94–104%[116]
Cocaine
Codeine
Methadone
Morphine
UrineMSPE-CE-DADFused silica capillary (71.5 cm effective length, 50 μm I.D.) with trapped magnetic particles
Aqueous solution of 40mM ammonium acetate adjusted with 28% ammonium hydroxide to pH 8.7
15 kV, 25 °C
14 minLOD = 2 ng/mLRSD = 6.5–13.8%[117]
Cocaine
Benzoylecgonine
6-acetylmorphine
Codeine
Morphine
Methadone
HairSPE-CE-DADFused silica capillary (80 cm total length, 50 µm I.D.)
11 mM α-cyclodextrin in an aqueous solution of 80 mM sodium phosphate at pH 2.530 kV, 25 °C
32 minLOD = 0.12 ng/mgRSD = 2.48-9.70%
Recovery = 87.85–95.32%
[118]
Imatinib
Metabolite (Imatinib)
Codeine
Morphine
UrineNACE-DADFused silica capillary (29 cm effective length, 75 µm I.D.)
15 mM ammonium acetate and 1% acetic acid in methanol
22 kV, 25 °C
9 minLOD = 40 ng/mLRecovery = 80.3–102.2%[121]
Morphine-3-β-glucuronide
Codeine-6-β-glucuronide
Naloxone-6-β-glucuronide
Ethyl-β-glucuronide
Standard and urineNACE-MSFused silica capillary (100 cm effective length, 50 µm I.D.) or uncoated fused silica capillary with a porous tip (100 cm effective length, 30 µm I.D.)
5 mM ammonium acetate in ACN-MeOH 60:40 (v/v)
30 kV
15 minLOD = 500 ng/mL-[122]
Promethazine
Codeine
Pharmaceutical formulationCE-C4DFused silica capillary (10 cm effective length, 50 µm I.D.)
10 mM oxalic acid and 1.8 mM triethanolamine at pH 8.425 kV
0.5 minLOD = 28,000 ng/mLRSD = 3.9–4.7%[59]
Quinine
Propranolol
Strychnine
Atropine
Nicotine
Codeine
StandardMECK-DADFused silica capillary (51.5 cm effective length, 50 µm I.D.)
46 mM aqueous sodium phosphate buffer, pH 2.1/ACN 80:20 v/v containing 70 mM SDS−15 kV
----[124]
Codeine
Morphine
Methamphetamine
Ketamine
Alprazolam
Clonazepam
Diazepam
Flunitrazepam
Nitrazepam
Oxazepam
UrineMECK-UVUncoated fused silica capillary (40.2 cm effective length, 50 µm I.D.)
50 mM NaH2PO4 buffer at pH 2.3 containing 10% methanol and 150 mM SDS
−15 kV, 25 °C
18 minLOD = 28,000 ng/mLRecovery = 77.6%[123]
Codeine
Diclofenac
Pharmaceutical formulationCE-C4DFused silica capillary (10 cm effective length, 50 µm I.D.)
10 mM Tris/Taps at pH 8.225 kV
1 minLOD = 21,000 nMRSD = 0.7–1.5%[42]
2-ethylidene-1,5-dimethyl- 3,3-diphenylpyrrolidine
Codeine
Hydrocodeine
6-acetylmorphine
UrineSPE-CE-MSFused silica capillary (91.5 cm effective length, 50 µm I.D.)
60 mM ammonium acetate at pH 3.8
30 kV
17 minLOD = 0.20 ng/mLRSD = 4.9%[119]
Morphine
Codeine
6-monoacetylmorphine
SalivaCE-UVFused silica capillary (60.3 cm effective length, 75 µm I.D.)
100 mM phosphate buffer at pH 3) containing 20% methanol and 5% isopropanol (v/v)
25 kV
20 minLOD = 7 ng/mLRSD = 6.1–17.7%[120]
2-ethylidene-1,5-dimethyl- 3,3-diphenylpyrrolidine
Codeine
Cocaine
6-acetylmorphine
WaterSPE-CE-UVFused silica capillary (53 cm effective length, 50 µm I.D.)
80 mM disodium phosphate anhydrous and 6 mM of HCl at pH 3
30 kV, 25 °C
7 minLOD = 200 ng/mLRSD = 3.2–7.6%[108]
3,4-methylenedioxyamphetamine
3,4-methylenedioxymethamphetamine
Methadone
Cocaine
Morphine
Codeine
6-monoacetylmorphine
HairCE-MSUncoated fused silica capillary (100 cm total length, 50 µm I.D.)
50 mM ammonium phosphate at pH 6.5
15 kV, 20 °C
25 minLOD = 0.002 ng/mg-[107]
Amphetamine
Methamphetamine
3,4-methylenedioxyamphetamine
3,4-methylenedioxymethamphetamine
Ketamine
Codeine
Acetylcodeine
Heroin
UrineCE-UVFused silica capillary (60 cm effective length, 75 µm I.D.)
30 mM PBS at pH 2.0 containing 15% v/v ACN
20 kV, 25 °C
15 minLOD = 53 ng/mLRSD = 2.8–12.4%
Recovery = 85.4–109.7%
[109]
Amphetamine
Ephedrine
Methadone
Pethidine
Tetracaine
Codeine
Heroin
Liver microsomesCE-MSFused silica capillary (70 cm effective length, 50 µm I.D.)
20 mM ammonium acetate at pH 9.022 kV, 25 °C
5 minLOD = 1.0 ng/mLRSD = 1.08–1.12%[110]
Morphine
Codeine
Thebaine
Plant extractsCE-UVFused silica capillary (50 cm effective length, 50 µm I.D.)
100 mM phosphate buffer pH 3.0 containing 5 mM α-cyclodextrin
20 kV, 25 °C
15 minLOD = 2000 ng/mLRSD = 1.6–2.9%
Recovery = 2.7%
[111]
Hebaine
Codeine
Morphine
Narcotine
Plant extractsCE-ECLUncoated fused silica capillary (50 cm effective length, 25 µm I.D.)
25 mM borax and 8mM EMImBF4 at pH 9.1815 kV
5 mM Ru(bpy)3 and 50mM phosphate at pH 9.18 (detection cell)
6 minLOD = 250 nMRSD = 4.11–5.01%[112]
C4D: capacitively coupled contactless conductivity detector; CE: capillary electrophoresis; CET: capillary electromigration techniques; DAD: diode array detector; ECL: electrochemiluminescence detector; I.D.: internal diameter; LOD: limit of detection; LOQ: limit of quantification; MSEP: magnetic solid-phase extraction, NACE: non-aqueous capillary electrophoresis, SEP: solid-phase extraction, TEA: triethanolamine; U: ultraviolet detector.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Pratiwi, R.; Noviana, E.; Fauziati, R.; Carrão, D.B.; Gandhi, F.A.; Majid, M.A.; Saputri, F.A. A Review of Analytical Methods for Codeine Determination. Molecules 2021, 26, 800. https://doi.org/10.3390/molecules26040800

AMA Style

Pratiwi R, Noviana E, Fauziati R, Carrão DB, Gandhi FA, Majid MA, Saputri FA. A Review of Analytical Methods for Codeine Determination. Molecules. 2021; 26(4):800. https://doi.org/10.3390/molecules26040800

Chicago/Turabian Style

Pratiwi, Rimadani, Eka Noviana, Rizky Fauziati, Daniel Blascke Carrão, Firas Adinda Gandhi, Mutiara Aini Majid, and Febrina Amelia Saputri. 2021. "A Review of Analytical Methods for Codeine Determination" Molecules 26, no. 4: 800. https://doi.org/10.3390/molecules26040800

APA Style

Pratiwi, R., Noviana, E., Fauziati, R., Carrão, D. B., Gandhi, F. A., Majid, M. A., & Saputri, F. A. (2021). A Review of Analytical Methods for Codeine Determination. Molecules, 26(4), 800. https://doi.org/10.3390/molecules26040800

Article Metrics

Back to TopTop