A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva
Abstract
:1. Introduction
2. Principle of Glucose Detection
3. Design and Fabrication
4. Results and Discussion
5. Conclusions
Acknowledgments
Author Contributions
Conflicts of Interest
References
- IDF Diabetes Atlas 8th Edition. Available online: http://www.diabetesatlas.org/ (accessed on 11 November 2017).
- UK Prospective Diabetes Study (UKPDS) Group. Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). Lancet 1998, 352, 837–853. [Google Scholar]
- The Diabetes, Control and Complications Trial Research, Group. The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes Mellitus. N. Engl. J. Med. 1993, 329, 977–986. [Google Scholar]
- Klonoff, D.C.; Perz, J.F. Assisted monitoring of blood glucose: Special safety needs for a new paradigm in testing glucose. J. Diabetes Sci. Technol. 2010, 4, 1027–1031. [Google Scholar] [CrossRef] [PubMed]
- Thompson, N.D.; Perz, J.F. Eliminating the blood: Ongoing outbreaks of hepatitis B virus infection and the need for innovative glucose monitoring technologies. J. Diabetes Sci. Technol. 2009, 3, 283–288. [Google Scholar] [CrossRef] [PubMed]
- Lamy, E.; Mau, M. Saliva proteomics as an emerging, non-invasive tool to study livestock physiology, nutrition and diseases. J. Proteom. 2012, 75, 4251–4258. [Google Scholar] [CrossRef] [PubMed]
- Kim, H.J.; Jeong, S.Y.; Noh, H.R. Quantitative determination of tear glucose using paper based microfluidic devices. J. Korean Chem. Soc. 2015, 3, 88–93. [Google Scholar] [CrossRef]
- Makaram, P.; Owens, D.; Acerous, J. Trends in nanomaterial-based non-invasive diabetes sensing technologies. Diagnostics 2014, 4, 27–46. [Google Scholar] [CrossRef] [PubMed]
- Moyer, J.; Wilson, D.; Finkelshtein, I.; Wong, B.; Potts, R. Correlation between sweat glucose and blood glucose in subjects with diabetes. Diabetes Technol. Ther. 2012, 14, 398–402. [Google Scholar] [CrossRef] [PubMed]
- Gupta, S.; Sandhu, S.V.; Bansal, H.; Sharma, D. Comparison of Salivary and Serum Glucose Levels in Diabetic Patients. J. Diabetes Sci. Technol. 2015, 9, 91–96. [Google Scholar] [CrossRef] [PubMed]
- Agrawal, R.P.; Sharma, N.; Rathore, M.S.; Gupta, V.B.; Jain, S.; Agarwal, V.; Gotal, S. Noninvasive Method for Glucose Lovel Estimation by Saliva. J. Diabetes Metab. 2013, 4, 1–5. [Google Scholar]
- Jurysta, C.; Bulur, N.; Oguzhan, B.; Satman, I.; Yilmaz, T.M.; Malaisse, W.J.; Sener, A. Salivary glucose concentration and excretion in normal and diabetic subjects. J. Biomed. Biotechnol. 2009, 2009. [Google Scholar] [CrossRef] [PubMed]
- Enejder, A.M.K.; Scecina, T.G.; Oh, J.; Hunter, M.; Shih, W.; Sasic, S.; Horowitz, G.L.; Feld, M.S. Raman spectroscopy for noninvasive glucose measurments. J. Biomed. Opt. 2005, 10, 031114. [Google Scholar] [CrossRef] [PubMed]
- Zhang, W.; Du, Y.; Wang, M.L. Noninvasive glucose monitoring using saliva nano-biosensor. Sens. Bio-Sens. Res. 2015, 4, 23–29. [Google Scholar] [CrossRef]
- Ahn, W.S.; Kim, J.T. Blood glucose measurement priciples of non-invasive blood glucose meter: Focused on the detection methods of blood glucose. J. Biomed. Eng. Res. 2012, 33, 114–127. [Google Scholar] [CrossRef]
- Daniel, F.; Devanand, P. Lab-on-a-chip: A revolution in biological and medical sciences. Anal. Chem. 2000, 72, 330–335. [Google Scholar]
- Geschk, O.; Klank, H.; Telleman, P. Microsystem Engineering of Lab-on-a-Chip Devices; Wiley-VCH Weinheim: Boschstrasse, Germany, 2008; pp. 1–7. [Google Scholar]
- Medoro, G.; Manaresi, N.; Leonardi, A.; Altomare, L.; Tartagni, M.; Guerrieri, R. A lab on-a-chip for cell detection and manipulation. IEEE Sens. J. 2003, 3, 317–325. [Google Scholar] [CrossRef]
- Hongbin, Y.; Guangya, Z.; Siong, C.F.; Shouhua, W.; Feiwen, L. Novel polydimethylsiloxane (PDMS) based microchannel fabrication method for lab-on-a-chip application. Sens. Actuators B Chem. 2009, 137, 754–761. [Google Scholar] [CrossRef]
- Wang, Z.; Haasch, R.T.; Lee, G.U. Mesoporous membrane device for asymmetric biosensing. Langmuir 2012, 21, 1153–1157. [Google Scholar] [CrossRef] [PubMed]
© 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Jung, D.G.; Jung, D.; Kong, S.H. A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva. Sensors 2017, 17, 2607. https://doi.org/10.3390/s17112607
Jung DG, Jung D, Kong SH. A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva. Sensors. 2017; 17(11):2607. https://doi.org/10.3390/s17112607
Chicago/Turabian StyleJung, Dong Geon, Daewoong Jung, and Seong Ho Kong. 2017. "A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva" Sensors 17, no. 11: 2607. https://doi.org/10.3390/s17112607
APA StyleJung, D. G., Jung, D., & Kong, S. H. (2017). A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva. Sensors, 17(11), 2607. https://doi.org/10.3390/s17112607