Next Article in Journal
Exploring the Feasibility of Estimating Intraocular Pressure Using Vibrational Response of the Eye: A Methodological Approach
Next Article in Special Issue
Design and Evaluation of Real-Time Data Storage and Signal Processing in a Long-Range Distributed Acoustic Sensing (DAS) Using Cloud-Based Services
Previous Article in Journal
Superconducting Quantum Magnetometer Based on Flux Focusing Effect for High-Sensitivity Applications
Previous Article in Special Issue
Polar Decomposition of Jones Matrix and Mueller Matrix of Coherent Rayleigh Backscattering in Single-Mode Fibers
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

High-Resolution and Large-Dynamic Range Fiber-Optic Sensors Based on Dual-Mode Direct Spectrum Interrogation Method

by
Min Zhou
1,2,
Zhe Zhang
1,*,
Qingyue Cui
1,
Qingdian Lin
1,
Jun Yu
1,
Xiaoyang Guo
1,*,
Cangtao Zhou
1 and
Shuangchen Ruan
1
1
Shenzhen Key Laboratory of Ultra-Intense Laser and Advanced Material Technology, Center for Intense Laser Application Technology, and College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
2
Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen 518118, China
*
Authors to whom correspondence should be addressed.
Sensors 2024, 24(12), 3996; https://doi.org/10.3390/s24123996
Submission received: 27 May 2024 / Revised: 17 June 2024 / Accepted: 18 June 2024 / Published: 20 June 2024

Abstract

:
Conventional optical fiber temperature/strain sensors often have to make compromises between the resolution and the dynamic range. Here we present a new method that meets the measurement requirements for both high resolution and large dynamic range. A high-quality optical fiber Fabry-Perot Interferometer (FPI) constructed using a pair of chirped fiber Bragg gratings is employed as the sensor and a dual-mode direct spectrum interrogation method is proposed to identify the small drift of external temperature or strain. As a proof-of-concept illustration, a temperature resolution of 0.2 °C within 30–130 °C is demonstrated. For strain sensing, the resolution can be 10 µε within 0–1000 µε. The measurement resolution can be improved further by routinely increasing the reflectivity of the CFBG and the cavity length and the sensor can also be mass-produced. This new sensing schema not only resolves the conflict between the resolution and the dynamic range of fiber-optic temperature/strain sensors but can also be extended to other sensors and measurands.

1. Introduction

Temperature and strain are two of the basic physical parameters that need to be precisely determined in a lot of application scenarios. Fiber FPIs have been extensively studied for sensing applications due to their superiorities such as high sensitivity, small size and weight, excellent suppleness, immunity to electromagnetic interference, and embedded measuring abilities [1,2,3,4,5]. For temperature or strain sensing, resolving the wavelength of the resonant peak or dip of FPIs is commonly adopted, where the resolution is limited by the bandwidth Δ λ of the resonant peak/dip within the spectra [6]. Early works have demonstrated that the resolution and detection limit of a fiber-optic sensor are closely related to the Q-factor by Q = λ / Δ λ [6] ( Δ λ is the bandwidth of the resonant peak/dip). Thus, narrowing the bandwidth ( Δ λ ) of the resonant peak/dip within the spectrum can greatly improve the resolution, followed by the detection limits. Recently, we narrowed the spectrum bandwidth Δ λ (i.e., improved the Q factor) of an opened air-cavity FPI gas pressure sensor by lengthening the cavity, where a pressure detection limit of 23 Pa is demonstrated [7]. However, the narrowing of the spectrum bandwidth Δ λ also minifies the free spectrum range (FSR) of the interference spectrum, resulting in reduced dynamic measurement range. This indicates that the detection resolution and dynamic range of conventional FPI sensors are mutually restrictive.
In-fiber Bragg gratings have been extensively employed in sensing applications [8,9,10]. The dynamic range for temperature and strain can be larger than 1000 °C [11] and 1000 µε [12], respectively. However, the resolution is limited by the large bandwidth (0.1–1 nm) of the FBG. Early works have constructed FPI sensors using two similar FBGs inscribed nearby [13,14,15], resulting in a narrower bandwidth of the tagged peak/dip within the spectrum while the FSR of the spectrum is reduced accordingly, restricting the dynamic range of the sensor. As such, new spectral interrogation methods are requisite for simultaneous high-resolution and large dynamic range sensing applications. In 2015, Liu et al. developed an average wavelength tracking method for a micro-fabricated fiber FPI sensor [16], where a temperature resolution of 6 × 10−4 °C is demonstrated. However, the fabrication in micron dimension and the complicated data processing constrain its practical applications. An FPI temperature sensor formed by a pair of FBGs was proposed by Li et al. in 2021 [17]. They replaced the conventional peak/dip wavelength resolving demodulation approach with laser frequency dither locking schema, by which a resolution of 7 × 10−4 °C within a dynamic range of ~46 °C is achieved. However, the method needs to convert the direct wavelength shift into the feedback voltage, where expensive source (DFB laser) and complex circuits, feedback, and control parts (lock-in amplifier, proportional-integral-derivative controller, etc.) are indispensable.
In this work, we propose and demonstrate a dual-mode direct spectrum interrogation approach for simultaneously high-resolution and large-dynamic range temperature or strain sensing. The sensor is constructed using a pair of Chirped Fiber Bragg Gratings (CFBGs) inscribed using an ultraviolet (UV) laser phase mask scanning setup. The prepared sensor yields a high Q factor of ~0.67 × 105. As a proof-of-concept, a temperature resolution of 0.2 °C within 30–130 °C is experimentally demonstrated. For strain sensing, the resolution can be 10 µε within 0–1000 µε. The proposed sensing schema not only resolves the conflict between the resolution and the dynamic range but simplifies the sensing system, which may find applications in in vivo temperature measurement of living organisms, ultrasonic hydrophones for medical sensing, and even seismic sensors for geophysical surveys.

2. Principle and Sensor Design

The proposed FPI sensor that was constructed using a pair of CFBGs is sketched in Figure 1a, where the two CFBGs are identical (i.e., similar reflection ratio and bandwidth). The grating pitch Λ ( z ) of the CFBG gradually increases or decreases along the fiber axis (z direction), resulting in a gradual change in the reflection wavelength. The phase-matching condition of the CFBG can be deduced from a uniform FBG [18] to: λ ( z ) = 2 n e f f ( z ) Λ ( z ) , where λ ( z ) and n e f f ( z ) denote the resonant wavelength and the effective index of the fundamental core mode, respectively, and Λ ( z ) represents the grating pitch of the CFBG. For linear chirped CFBG, the grating pitch varies linearly along the fiber axis according to Λ ( z ) = Λ 0 + C z ; where Λ 0 represents the grating pitch at the starting position and C represents the chirp rate. When two identical CFBGs are inscribed in the fiber core one by one, the reflected light from the two CFBGs will result in an interference pattern in the frequency domain according to the white-light interference principles. Assuming the two CFBGs have the same reflection rate of R0, and the distance between the edges of the two CFBGs is L0. The reflection spectrum I R ( λ ) of the CFBG-based FPI can be expressed as [19]:
I R ( λ ) = I 0 ( λ ) R 0 + R 0 η 2 R 0 η cos   [ 4 π n e f f L 0 λ + φ 0 ] 1 + R 0 2 η 2 R 0 η cos   [ 4 π n e f f L 0 λ + φ 0 ] ,
where n eff and η denote the average effective index and the transmission coefficient of the cavity. For the CFBG-based FPI (intrinsic FPI), the transmission coefficient η is ~1 since the optical loss of the cavity is close to zero. I 0 ( λ ) represents the incident spectrum within the reflection bandwidth of the CFBG and φ 0 denotes the initial phase difference of the two reflected beams. As such, the reflection spectrum can be represented by:
I R ( λ ) = I 0 ( λ ) 2 R 0 2 R 0 cos   [ 4 π n e f f L 0 λ + φ 0 ] 1 + R 0 2 2 R 0 cos   [ 4 π n e f f L 0 λ + φ 0 ] ,
It has been demonstrated that a higher Q factor (defined as Q = λλ) of the resonant peak/dip renders higher resolution and lower errors [6]. As such, small temperature or strain drift can be precisely determined by tracking the resonant peak/dip within the interference spectrum. Figure 1b shows the simulated reflection spectra of the CFBG-based FPIs with different R0 of 0.2, 0.4, and 0.8, (assuming the cavity length is 10 mm), where the FWHMs are 0.031 nm, 0.021 nm, and 0.006 nm, respectively. Figure 1c exhibits the reflection spectra of the FPIs with different cavity lengths of 5 mm, 10 mm, and 15 mm (assuming the reflection of CFBG is 0.2), where the corresponding FWHMs are 0.063 nm, 0.031 nm, and 0.021 nm, respectively. As such, for high-resolution temperature/strain sensing, increasing the reflection ratio R0 and cavity length L0 are both effective.
The increases in cavity length L0 reduce the free spectrum range (FSR) accordingly (FSR = λ2/2nL0). It is well known that when the drift of the resonant peak/dip is larger than the FSR, the resonant peak/dip can be hardly identified and tracked, resulting in a limited dynamic measurement range. As a result, the conventional spectrum interrogation approach can hardly balance the resolution and dynamic range of the measurement while for the proposed CFBG-based FPIs, the envelope of the interference spectrum may be tracked for large dynamic range measurements since the envelope is essentially the reflection spectrum of the CFBG, which manifests as a single peak with nearly infinite FSR. Thus, we can develop a direct spectrum-domain interrogation method (i.e., the dual-mode spectrum interrogation approach) for both the sharp resonant dip and envelope to identify the tiny external changes within large dynamic ranges.

3. Sensor Fabrication

A chirped phase mask with a pitch of 1070 nm and a chirp rate of 10 nm/cm is employed for CFBG inscription. A 266 nm, pulse UV laser with pulse width and repetition ratio of 1.5 nm and 10 kHz is employed for inscription. The resulting center wavelength of CFBG is ~1550 nm, according to the grating equation λ ( z ) = 2 n Λ ( z ) , and the reflection bandwidth of the CFBG is proportional to scanning length L. The scanning setup for CFBG fabrication is sketched in Figure 2a, which is similar to [20]. A CFBG (CFBG1) is first inscribed in a hydrogen-load single-mode fiber (SMF-28). The scanning length (i.e., CFBG1 length (L)) is precisely controlled at ~5.4 mm, resulting in a reflection bandwidth of ~7.8 nm. Then, the fiber is moved axially (z direction) for a distance (L0 = 6.9 mm) and the same inscription process is repeated, with the same CFBG (CFBG2) inscribed. In this process, the variation in the grating pitches Λ ( z ) for the two CFBGs are in the same direction, resulting in a similar cavity length L0 for each reflection wavelength (as sketched in Figure 1a). Light launched into the fiber will be reflected by the two CFBGs and the reflected light will interfere with the frequency domain (blue line within Figure 2b). Inferring from the transmission spectrum (orange line within Figure 2b), the reflection of the two CFBGs is ~30%. The FSR of the interference spectrum is identified as ~0.12 nm, which agrees well with the designed cavity length (L0) of ~6.9 mm. The FWHM Δ λ of the CFBG-based FPI (FPI1) is identified as ~0.036 nm, corresponding to a Q factor of ~4.3 × 104. The sensor is finally annealed in a 120 °C oven for 12 h to get a stable spectrum.

4. Sensing Performance and Discussion

4.1. High-Resolution and Large-Dynamic Range Temperature Sensing

Proof-of-concept temperature tests are then carried out, where a high-precision (0.1 °C) digital temperature oven that is similar to [21] is employed and an ultrahigh-resolution (0.005 nm) optical spectrum analyzer (OSA: Yokogawa, AQ6380, Tokyo, Japan) and a supercontinuum source (YSL-SC-5) are employed for online monitoring of the temperature-induced wavelength drift. FPI1 is placed in the center of the oven and the temperature is increased from 35 to 40.5 °C in steps of 0.5 °C. Figure 3a shows the variation in a resonant dip located at ~1550 nm grey-shaded area) versus the temperature. Between each temperature step (0.5 °C), ~0.007 nm wavelength drift can be clearly identified. Figure 3b shows the experimental and linear fit results, where the temperature sensitivity is ~13.48 pm/°C, with R2 of 0.997. It is worth noting that the proposed sensor is sensitive to both temperature and strain, as such, the setup for temperature tests must be carefully designed to maintain the accuracy and reliability of the tests. We place the sensor in a temperature oven with two sides opened for the sensor pigtails. The pigtails of the sensor are naturally released to reduce the strain effects.
The lengthening of the cavity can improve the spectrum Q factor and thus the temperature resolution while the FSR of the spectrum is reduced accordingly, restricting the temperature dynamic range. According to the aforementioned solution, the envelope of the interference spectrum may be tracked for large dynamic range measurements. To verify this approach, temperature tests within a larger dynamic range are then carried out. The temperature is increased from 30 °C to 130 °C in steps of 20 °C, and the reflection spectrum evolution is recorded and plotted in Figure 4a. The envelope of the reflection spectrum can be routinely extracted as shown in Figure 4b. As long as the envelope is extracted, the center wavelength of the envelope peak can be easily extracted. By tracking the center wavelength of the envelope versus temperature change, temperature information can be obtained and calibrated. Figure 4c shows the tracked center wavelength of the envelope versus the temperature, where a sensitivity of 12.93 pm/°C is obtained by a linear fit (R2 = 0.993). The cooling process is also monitored and the result is shown in Figure 4d–f. A temperature sensitivity of ~13.08 pm/°C (R2 = 0.998) is obtained. The little deviation in temperature response between the heating and cooling processes may be attributed to thermal stress release as well as experimental errors.

4.2. High Resolution and Large Dynamic Range Strain Sensing

The proposed sensor and spectrum interrogation approach can also be employed for other measurands, such as strain. The sharp resonant dip within the interference spectrum, as well as the spectrum envelope (i.e., the spectrum of CFBG), will shift with tensile strains due to the elastic-optic effect as well as the lengthening of the cavity. As a proof-of-concept, the strain response of the CFBG-FPI (FPI1) is then studied experimentally at room temperature (25 °C), the setup of which is similar to our previous work [12]. To reduce temperature crosstalk, the sensor is placed in a thermostatic oven (temperature stability: 0.1 °C) with two sides opened for the sensor pigtails. The applied strain is increased from 0 µε to 70 µε in steps of 10 µε and the resonant dip at ~1550 nm is marked and tracked (grey-shaded area). At each step, ~0.013 nm wavelength shift of the resonant dip can be clearly identified. Figure 5 shows the tracked wavelength of the dip versus the applied strain, where a sensitivity of ~1.29 pm/µε can be obtained by linear fit (R2 = 0.999).
It is worth noting that the strain resolution of the sensor (FPI1) is higher than 10 µε. While limited by the experimental setups, higher resolution tests need to be further designed and constructed. This work merely gives a proof-of-concept experimental illustration.
For larger dynamic range strain sensing, the dual-mode spectrum interrogation approach can be employed. Figure 6a,d illustrates the recorded reflection spectrum evolutions with strain increasing (0–1000 µε) and decreasing (1000 µε to 0 µε) in a step of 20 µε. The envelopes of the reflection spectra are extracted and shown in Figure 6b,e. The center wavelength of the envelope varies with the applied strain, where a sensitivity of ~1.24 pm/με is obtained by a linear fit of the data (R2 = 0.999). The sensitivity is comparable to the results obtained by tracking one of the resonant dips within the interference spectrum.

4.3. Performance Improvement

A higher Q-factor CFBG-based FPI (FPI2) is then prepared to improve the measurement resolution further. The cavity length (L0) is increased to ~15.1 mm and the corresponding reflection (blue line) and transmission spectra (orange line) are shown in Figure 7a. Figure 7a is an enlarged view of the reflection spectrum near 1550 nm, where we can see that the FSR and bandwidth ( Δ λ ) of the resonant dip are reduced to ~0.055 nm and ~0.023 nm, respectively. The Q factor of the resonant (interference) dip is calculated as ~0.67 × 105. Such a high Q-factor resonant dip can be tracked to distinguish smaller temperature drifts.
The FPI2 is then employed for smaller temperature drift identifications. The temperature is increased from 36 °C to 37.4 °C (temperature of most living bodies) in a step of 0.2 °C, and the spectrum evolution is shown in Figure 8a. Figure 8b shows the tracked dip near 1550 nm versus the temperature, where a smaller wavelength drift of ~0.002 nm can be identified during each temperature step. We can clearly see that the resonant dip within the reflection spectrum shifts toward longer wavelengths with the temperature increasing, and the temperature sensitivity is ~11.15 pm/°C by a linear fit of the experimental results (R2 = 0.998). This result indicates that the proposed sensor can precisely identify a temperature change of less than 0.2 °C. Further on, we experimentally studied the long-term stability of the sensor by placing the sensor in a constant environment (40 °C) for three hours. The wavelength of the tracked dip was recorded, where the average wavelength and standard deviation were calculated to be 1550.157 nm and 0.00135 nm, respectively. The results indicate the excellent long-term stability of the sensor.
It is worth noting that: (1) the temperature resolution of FPI2 is higher than 0.2 °C, the presented experiment is limited by the accuracy and resolution of the employed temperature oven; (2) The cavity length L0 of the FPI can be routinely increased further by controlling the translation distance of the fiber relative to the phase mask. Since the in-fiber cavity has extremely low loss (η ≈ 1), the cavity can be lengthened infinitely as long as it provides suitable spectrum readout setups; (3) The reflection of the CFBGs can also be further increased by repeat scanning or increasing the power of the UV lasers. The two strategies (i.e., (2) and (3)) together with the Q factor of the resonant (interference) dip can be significantly improved, yielding an ultrahigh resolution and a large dynamic range sensor; (4) Temperature and strain crosstalk existed in the proposed sensor structure. However, the crosstalk can be resolved using a lot of strategies, including compensation and coefficient matrix strategies [22,23,24,25].

5. Conclusions

In conclusion, we present a dual-mode direct spectrum interrogation approach for simultaneously sensing high resolution and large dynamic range temperature/strain. As a proof-of-concept demonstration, temperature and strain resolution of 0.2 °C and 10 µε within dynamic ranges of 30–130 °C and 0–1000 µε, respectively, are experimentally illustrated. The resolution can be improved further by increasing the reflectivity of the CFBG and the cavity length. The proposed sensing schema can resolve the conflict between the resolution and the dynamic range of fiber-optic sensors effectively and can be extended to other sensors and measurands. However, the reflection of the CFBG is not high enough in this work, hence restricting further improvement of the Q factor and thus the resolution. Future efforts can be made to optimize the CFBG inscription process to improve the reflection of the CFBGs. An automatic dual-mode spectrum interrogation algorithm is also urgently needed for practical applications.

Author Contributions

All authors jointly conceived the idea; M.Z., Z.Z., Q.C., Q.L. and X.G. designed and fabricated the devices; M.Z. and Z.Z. built the experimental setup and performed the experiments; M.Z., Z.Z. and Q.C. performed the data analysis; M.Z., Z.Z. and X.G. wrote the first draft of the paper, and all authors contributed to the final version. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Natural Science Foundation of China (62305232); the Guangdong Basic and Applied Basic Research Foundation (2023A1515010054, 2021A1515110270); the Shenzhen Science and Technology Program (JCYJ20230807113924050); and the Natural Science Foundation of Top Talent of SZTU (GDRC202313).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are available from the corresponding author and can be provided upon appropriate request.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Rao, Y.J.; Deng, M.; Zhu, T.; Li, H. In-line Fabry–Perot etalons based on hollow-core photonic bandgap fibers for high-temperature applications. J. Lightwave Technol. 2009, 27, 4360–4365. [Google Scholar]
  2. Bae, H.; Yu, M. Miniature Fabry–Perot pressure sensor created by using UV-molding process with an optical fiber-based mold. Opt. Express 2012, 20, 14573–14583. [Google Scholar] [CrossRef] [PubMed]
  3. Zhu, J.L.; Wang, M.; Yang, C.D.; Wang, T.T. Miniature fiber Fabry-Perot sensors based on fusion splicing. Optoelectron. Lett. 2013, 9, 85–88. [Google Scholar] [CrossRef]
  4. Fu, X.H.; Xie, H.Y.; Wang, F.; Jiang, P.; Fu, G.W.; Bi, W.H. Miniature Fabry-Perot interferometric sensor for temperature measurement based on photonic crystal fiber. Optoelectron. Lett. 2015, 11, 382–385. [Google Scholar] [CrossRef]
  5. Zhang, Z.; Wang, Y.Y.; Zhou, M.; He, J.; Liao, C.R.; Wang, Y.P. Recent advance in hollow-core fiber high-temperature and high-pressure sensing technology [Invited]. Chin. Opt. Lett. 2021, 19, 070601. [Google Scholar] [CrossRef]
  6. White, I.M.; Fan, X.D. On the performance quantification of resonant refractive index sensors. Opt. Express 2008, 16, 1020–1028. [Google Scholar] [CrossRef]
  7. Zhang, Z.; He, J.; Dong, Q.; Bai, Z.Y.; Liao, C.R.; Wang, Y.; Liu, S.; Guo, K.K.; Wang, Y.P. Diaphragm-free gas-pressure sensor probe based on hollow-core photonic bandgap fiber. Opt. Lett. 2018, 43, 3017–3020. [Google Scholar] [CrossRef] [PubMed]
  8. Rao, Y.J. In-fibre Bragg grating sensors. Meas. Sci. Technol. 1997, 8, 355–375. [Google Scholar] [CrossRef]
  9. Zhang, B.W.; Kahrizi, M. High-temperature resistance fiber Bragg grating temperature sensor fabrication. IEEE Sensors J. 2007, 7, 586–591. [Google Scholar] [CrossRef]
  10. Guo, K.K.; He, J.; Cao, S.Q.; Hou, M.X.; Zhang, Z.; Xu, G.X.; Wang, Y.P. Beat frequency tuning in dual-polarization distributed feedback fiber laser using side polishing technique. Opt. Express 2018, 26, 34699–34710. [Google Scholar] [CrossRef]
  11. Wang, C.; Zhang, J.C.; Zhang, C.Z.; He, J.; Lin, Y.C.; Jin, W.; Liao, C.R.; Wang, Y.; Wang, Y.P. Bragg gratings in suspended-core photonic microcells for high-temperature applications. J. Lightwave Technol. 2018, 36, 2920–2924. [Google Scholar] [CrossRef]
  12. Zhu, F.; Zhang, Z.; Liao, C.R.; Wang, Y.; Xu, L.; He, J.; Wang, C.; Li, Z.Y.; Yang, T.H.; Wang, Y.P. Taper embedded phase-shifted fiber Bragg grating fabricated by femtosecond laser line-by-line inscription. IEEE Photon. J. 2017, 9, 7500208. [Google Scholar] [CrossRef]
  13. Yulianti, I.; Supa At, A.S.M.; Idrus, S.M.; Anwar, M.R.S. Design of fiber Bragg grating-based Fabry–Perot sensor for simultaneous measurement of humidity and temperature. Optik 2013, 124, 3919–3923. [Google Scholar] [CrossRef]
  14. Wang, K.; Wang, B.; Yan, B.; Sang, X.Z.; Yuan, J.H.; Peng, G.D. Simultaneous measurement of absolute strain and differential strain based on fiber Bragg grating Fabry-Perot sensor. Opt. Commun. 2013, 307, 101–105. [Google Scholar] [CrossRef]
  15. Ismail, N.; Hafizi, Z.M.; Ooi, C.W.; Zaini, M.K.A.B.; Nizwan, C.K.E.; Lim, K.S.; Ahmad, H. Fiber Bragg grating-based Fabry-Perot interferometer sensor for damage detection on thin aluminum plate. IEEE Sensors J. 2020, 20, 3564–3571. [Google Scholar] [CrossRef]
  16. Liu, G.; Han, M.; Hou, W. High-resolution and fast-response fiber-optic temperature sensor using silicon Fabry-Pérot cavity. Opt. Express 2015, 23, 7237–7247. [Google Scholar] [CrossRef] [PubMed]
  17. Li, G.; Ji, L.T.; Li, G.Q.; Su, J.; Wu, C. High-resolution and large-dynamic-range temperature sensor using fiber Bragg grating Fabry-Pérot cavity. Opt. Express 2021, 29, 18523–18529. [Google Scholar] [CrossRef]
  18. Erdogan, T. Fiber grating spectra. J. Lightwave Technol. 1997, 15, 1277–1294. [Google Scholar] [CrossRef]
  19. Amnon Yariv, P.Y. Photonics: Optical Electronics in Modern Communications, 6th ed.; Oxford University Press: New York, NY, USA, 2006. [Google Scholar]
  20. Zhou, J.T.; Guo, K.K.; He, J.; Hou, M.X.; Zhang, Z.; Liao, C.R.; Wang, Y.; Xu, G.X.; Wang, Y.P. Novel fabrication technique for phase-shifted fiber Bragg gratings using a variable-velocity scanning beam and a shielded phase mask. Opt. Express 2018, 26, 13311–13321. [Google Scholar] [CrossRef] [PubMed]
  21. Zhang, Z.; Zhou, M.; Wang, C.; Wang, Y.Y.; Guo, X.Y.; Zhou, C.T.; Ruan, S.C. Temperature-immune Fabry-Perot cavity sensor based on an opened hollow-core anti-resonant fiber. Opt. Express 2023, 31, 5483–5491. [Google Scholar] [CrossRef]
  22. Yin, G.L.; Wang, Y.P.; Liao, C.R.; Liu, Y.J.; Liu, S.; Wang, Q.; Yang, K.M.; Tang, J.; Zhong, X.Y. Simultaneous refractive index and temperature measurement with LPFG and liquid-filled PCF. IEEE Photonic. Tech. Lett. 2015, 27, 375–378. [Google Scholar] [CrossRef]
  23. Zhang, Z.; He, J.; Du, B.; Zhang, F.C.; Guo, K.K.; Wang, Y.P. Measurement of high pressure and high temperature using a dual-cavity Fabry-Perot interferometer created in cascade hollow-core fibers. Opt. Lett. 2018, 43, 6009–6012. [Google Scholar] [CrossRef] [PubMed]
  24. Bian, Q.; Podhrazsky, A.; Bauer, C.; Stadler, A.; Buchfellner, F.; Kuttler, R.; Jakobi, M.; Volk, W.; Koch, A.W.; Roths, J. Temperature and external strain sensing with metal-embedded optical fiber sensors for structural health monitoring. Opt. Express 2022, 30, 33449–33464. [Google Scholar] [CrossRef] [PubMed]
  25. Liang, J.Q.; Yu, Y.; Bian, Q.; Xu, W.J.; Wang, Z.C.; Zhang, S.M.; Weng, J.J.; Zhu, J.J.; Chen, Y.; Hu, X.Y.; et al. Metal-coated high-temperature strain optical fiber sensor based on cascaded air-bubble FPI-FBG structure. Opt. Express 2023, 31, 16795–16811. [Google Scholar] [CrossRef]
Figure 1. (a) Schematic of the proposed FPI sensor, the iridescent arrows represent the incident and reflected light, respectively; (b) The simulated reflection spectra of three FPI sensors with CFBG reflection R0 of 0.2, 0.4, and 0.8 (the cavity length L0 is assumed to be 10 mm); (c) The simulated reflection spectra of three FPI sensors with cavity length L0 of 5 mm, 10 mm, and 15 mm (the CFBG reflection R0 is assumed to be 0.2 mm).
Figure 1. (a) Schematic of the proposed FPI sensor, the iridescent arrows represent the incident and reflected light, respectively; (b) The simulated reflection spectra of three FPI sensors with CFBG reflection R0 of 0.2, 0.4, and 0.8 (the cavity length L0 is assumed to be 10 mm); (c) The simulated reflection spectra of three FPI sensors with cavity length L0 of 5 mm, 10 mm, and 15 mm (the CFBG reflection R0 is assumed to be 0.2 mm).
Sensors 24 03996 g001
Figure 2. (a) Schematic diagram of the CFBG preparation system, including a UV laser operating at 266 nm, a chirped phase mask, and electronic scanning stages; (b) Reflection (blue line) and transmission (orange line) spectra of the prepared FPI1 sensor with a cavity length L0 of ~6.9 mm.
Figure 2. (a) Schematic diagram of the CFBG preparation system, including a UV laser operating at 266 nm, a chirped phase mask, and electronic scanning stages; (b) Reflection (blue line) and transmission (orange line) spectra of the prepared FPI1 sensor with a cavity length L0 of ~6.9 mm.
Sensors 24 03996 g002
Figure 3. (a) The resonant dip evolution of FPI1 with temperature increasing from 35 to 40.5 °C in steps of 0.5 °C; (b) The wavelength of the tracked resonant dip versus the temperature.
Figure 3. (a) The resonant dip evolution of FPI1 with temperature increasing from 35 to 40.5 °C in steps of 0.5 °C; (b) The wavelength of the tracked resonant dip versus the temperature.
Sensors 24 03996 g003
Figure 4. (a) The reflection spectrum and (b) spectral envelope evolutions of FPI1 with temperature increasing from 30 °C to 130 °C; (c) The center wavelength of the reflection spectral envelope versus the temperature; (d) The reflection spectrum and (e) spectral envelope evolutions of FPI1 with temperature decreasing from 130 °C to 30 °C; (f) The center wavelength of the reflection spectral envelope versus the temperature.
Figure 4. (a) The reflection spectrum and (b) spectral envelope evolutions of FPI1 with temperature increasing from 30 °C to 130 °C; (c) The center wavelength of the reflection spectral envelope versus the temperature; (d) The reflection spectrum and (e) spectral envelope evolutions of FPI1 with temperature decreasing from 130 °C to 30 °C; (f) The center wavelength of the reflection spectral envelope versus the temperature.
Sensors 24 03996 g004
Figure 5. (a) The resonant dip evolution of FPI1 with tensile strain increasing from 0 με to 70 με; (b) The wavelength shifts of the tracked resonant dip versus applied strain.
Figure 5. (a) The resonant dip evolution of FPI1 with tensile strain increasing from 0 με to 70 με; (b) The wavelength shifts of the tracked resonant dip versus applied strain.
Sensors 24 03996 g005
Figure 6. (a) The reflection spectrum and (b) spectral envelope evolutions of FPI1 with strain increasing from 0 με to 1000 με; (c) The center wavelength of the reflection spectral envelope shifts versus applied strain; (d) The reflection spectrum and (e) spectral envelope evolutions of FPI1 with strain decreasing from 1000 με to 0 με; (f) The center wavelength shifts versus applied strain.
Figure 6. (a) The reflection spectrum and (b) spectral envelope evolutions of FPI1 with strain increasing from 0 με to 1000 με; (c) The center wavelength of the reflection spectral envelope shifts versus applied strain; (d) The reflection spectrum and (e) spectral envelope evolutions of FPI1 with strain decreasing from 1000 με to 0 με; (f) The center wavelength shifts versus applied strain.
Sensors 24 03996 g006
Figure 7. (a) Reflection (blue line) and transmission (orange line) spectra of the FPI2 with a cavity length of ~15.1 mm, the red lines represent the envelop of the spectrum; (b) Enlarged view of the reflection spectrum, where the bandwidth Δ λ and FSR are ~0.023 and ~0.055 nm, respectively.
Figure 7. (a) Reflection (blue line) and transmission (orange line) spectra of the FPI2 with a cavity length of ~15.1 mm, the red lines represent the envelop of the spectrum; (b) Enlarged view of the reflection spectrum, where the bandwidth Δ λ and FSR are ~0.023 and ~0.055 nm, respectively.
Sensors 24 03996 g007
Figure 8. (a) The resonant dip evolution of FPI2 with temperature increasing from 36 °C to 37.4 °C (temperature of most living bodies); (b) The wavelength of the tracked resonant dip versus the temperature.
Figure 8. (a) The resonant dip evolution of FPI2 with temperature increasing from 36 °C to 37.4 °C (temperature of most living bodies); (b) The wavelength of the tracked resonant dip versus the temperature.
Sensors 24 03996 g008
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Zhou, M.; Zhang, Z.; Cui, Q.; Lin, Q.; Yu, J.; Guo, X.; Zhou, C.; Ruan, S. High-Resolution and Large-Dynamic Range Fiber-Optic Sensors Based on Dual-Mode Direct Spectrum Interrogation Method. Sensors 2024, 24, 3996. https://doi.org/10.3390/s24123996

AMA Style

Zhou M, Zhang Z, Cui Q, Lin Q, Yu J, Guo X, Zhou C, Ruan S. High-Resolution and Large-Dynamic Range Fiber-Optic Sensors Based on Dual-Mode Direct Spectrum Interrogation Method. Sensors. 2024; 24(12):3996. https://doi.org/10.3390/s24123996

Chicago/Turabian Style

Zhou, Min, Zhe Zhang, Qingyue Cui, Qingdian Lin, Jun Yu, Xiaoyang Guo, Cangtao Zhou, and Shuangchen Ruan. 2024. "High-Resolution and Large-Dynamic Range Fiber-Optic Sensors Based on Dual-Mode Direct Spectrum Interrogation Method" Sensors 24, no. 12: 3996. https://doi.org/10.3390/s24123996

APA Style

Zhou, M., Zhang, Z., Cui, Q., Lin, Q., Yu, J., Guo, X., Zhou, C., & Ruan, S. (2024). High-Resolution and Large-Dynamic Range Fiber-Optic Sensors Based on Dual-Mode Direct Spectrum Interrogation Method. Sensors, 24(12), 3996. https://doi.org/10.3390/s24123996

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop