Next Article in Journal
Power Quality and Energy Efficiency in the Pre-Evaluation of an Outdoor Lighting Renewal with Light-Emitting Diode Technology: Experimental Study and Amortization Analysis
Previous Article in Journal
Natural Gas Hydrate as a Storage Mechanism for Safe, Sustainable and Economical Production from Offshore Petroleum Reserves
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Arsalis A.; Alexandrou, A.N.; Georghiou, G.E. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System. Energies 2016, 9, 663

by
Alexandros Arsalis
1,2,*,
Andreas N. Alexandrou
1,2 and
George E. Georghiou
2,3
1
Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia 1678, Cyprus
2
FOSS Research Centre for Sustainable Energy, University of Cyprus, Nicosia 1678, Cyprus
3
Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus
*
Author to whom correspondence should be addressed.
Energies 2017, 10(6), 829; https://doi.org/10.3390/en10060829
Submission received: 27 May 2017 / Revised: 15 June 2017 / Accepted: 15 June 2017 / Published: 21 June 2017
We have found two inadvertent errors in our paper [1], and thus would like to make the following corrections:
  • On page 1, the last sentence of the Abstract should be changed from:
    Overall the proposed system generates a total energy output of 210,520 kWh (during its whole lifetime), which translates to a unit cost of 17 €/kWh.
    to the following correct version:
    Overall, the proposed system generates a total electrical energy output of 52,433 MWh (during its whole lifetime), which translates to a unit cost of electricity of 0.067 €/kWh.
  • Furthermore, on page 14, the first two sentences of the second paragraph of the Conclusions section should be changed from:
    Overall, the proposed PV-assisted CCHP system generates the following amounts of useful energy (energy that is actually utilized in the load profile throughout the total lifetime (20 years) of the system): 83,140 kWh of electrical energy, 60,960 kWh of heating energy and 66,420 kWh of cooling energy. Therefore, for a total energy output of 210,520 kWh, this results in a unit cost of 17 €/kWh.
    to the following correct version:
    Overall, the proposed PV-assisted CCHP system generates the following amounts of useful energy (energy that is actually utilized in the load profile throughout the total lifetime (20 years) of the system): 33,940 MWh of electrical energy, 26,580 MWh of heating energy, and 28,900 MWh of cooling energy. For comparison to a conventional system, where heating and cooling energies are supplied through an electric heat pump unit with an assumed average COP value of 3.0, the heating and cooling energies correspond to an electrical input of 8860 MWh and 9633 MWh, respectively. Therefore, for a total electrical energy output of 52,433 MWh, this results in a unit cost of electricity of 0.067 €/kWh.
The authors apologize for any inconvenience caused to the readers. The change does not affect the scientific results. The manuscript will be updated and the original will remain online on the article webpage.

Reference

  1. Arsalis, A.; Alexandrou, A.N.; Georghiou, G.E. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System. Energies 2016, 9, 663. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Arsalis, A.; Alexandrou, A.N.; Georghiou, G.E. Correction: Arsalis A.; Alexandrou, A.N.; Georghiou, G.E. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System. Energies 2016, 9, 663. Energies 2017, 10, 829. https://doi.org/10.3390/en10060829

AMA Style

Arsalis A, Alexandrou AN, Georghiou GE. Correction: Arsalis A.; Alexandrou, A.N.; Georghiou, G.E. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System. Energies 2016, 9, 663. Energies. 2017; 10(6):829. https://doi.org/10.3390/en10060829

Chicago/Turabian Style

Arsalis, Alexandros, Andreas N. Alexandrou, and George E. Georghiou. 2017. "Correction: Arsalis A.; Alexandrou, A.N.; Georghiou, G.E. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System. Energies 2016, 9, 663" Energies 10, no. 6: 829. https://doi.org/10.3390/en10060829

APA Style

Arsalis, A., Alexandrou, A. N., & Georghiou, G. E. (2017). Correction: Arsalis A.; Alexandrou, A.N.; Georghiou, G.E. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System. Energies 2016, 9, 663. Energies, 10(6), 829. https://doi.org/10.3390/en10060829

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop