Hybrid Multimodule DC-DC Converters for Ultrafast Electric Vehicle Chargers

Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
*
Author to whom correspondence should be addressed.
Energies 2020, 13(18), 4949; https://doi.org/10.3390/en13184949
Submission received: 16 August 2020 / Revised: 4 September 2020 / Accepted: 15 September 2020 / Published: 21 September 2020

Abstract

:
To increase the adoption of electric vehicles (EVs), significant efforts in terms of reducing the charging time are required. Consequently, ultrafast charging (UFC) stations require extensive investigation, particularly considering their higher power level requirements. Accordingly, this paper introduces a hybrid multimodule DC-DC converter-based dual-active bridge (DAB) topology for EV-UFC to achieve high-efficiency and high-power density. The hybrid concept is achieved through employing two different groups of multimodule converters. The first is designed to be in charge of a high fraction of the total required power, operating at a relatively low switching frequency, while the second is designed for a small fraction of the total power, operating at a relatively high switching frequency. To support the power converter controller design, a generalized small-signal model for the hybrid converter is studied. Also, cross feedback output current sharing (CFOCS) control for the hybrid input-series output-parallel (ISOP) converters is examined to ensure uniform power-sharing and ensure the desired fraction of power handled by each multimodule group. The control scheme for a hybrid eight-module ISOP converter of 200 kW is investigated using a reflex charging scheme. The power loss analysis of the hybrid converter is provided and compared to conventional multimodule DC-DC converters. It has been shown that the presented converter can achieve both high efficiency ( 99.6 % ) and high power density (10.3 kW/L), compromising between the two other conventional converters. Simulation results are provided using the MatLab/Simulink software to elucidate the presented concept considering parameter mismatches.

Graphical Abstract

1. Introduction

Despite the fact that internal combustion engines (ICEs) have been a mature technology for the past 100 years, it is expected that electric vehicles (EVs) will break the monopoly of conventional vehicles using only ICEs because of their performance and superior fuel economy [1]. Due to the strict regulations on global warming and energy resources constraints, and on reducing fossil fuel prices as well as gas emissions, environmental awareness has led to a high interest in EVs as an alternative solution for further improvement compared to ICEs [2,3]. To increase the adoption of EVs, significant efforts in terms of reducing the charging time are required. Consequently, to allow massive market penetration of EVs, the concept of ultrafast charging (UFC) requires more investigation. In this regard, several research studies targeting fast chargers and UFC for EVs have been provided in the literature [4,5,6,7,8]. UFC technology is a high power charging technology ( 400   kW ) that can replace or substitute the ICE technology and can charge EVs’ battery packs in 10   min [9,10,11].
Advanced power electronics converters are considered as key enabling technologies for realizing EV UFC, where high-power DC-DC converters are needed. The critical requirements for designing EV battery chargers are high efficiency, low cost, high power density, and galvanic isolation [12]. Furthermore, one of the UFC stations’ requirements is to design the DC-DC converters in a modular manner to offer easy maintenance, as well as scalability, redundancy, and fault ride-through capability [13,14,15]. In modular power converters, each unit handles a small portion of the total input power. Accordingly, the selected power switches are of lower voltage and/or current ratings; therefore, higher switching frequency capability, consequently, reduced weight and size [16,17,18]. Multimodule DC-DC converters can provide a bidirectional power flow through employing submodules that are based on dual active bridge (DAB), dual half bridge (DHB), or series resonant topologies [19,20].
The DAB configuration, shown in Figure 1, consists of two active bridges that are connected via a medium/high-frequency AC transformer. DAB can be constructed using a single-phase bridge or a three-phase bridge depending on the design criteria. The 2L-DAB, shown in Figure 1, usually operates in a square wave mode. The intermediate transformer leakage inductance limits the maximum power flow and is used as the energy transferring element. This topology is capable of bidirectional power flow that can be achieved by controlling the phase shift between the two bridges and the magnitude of the output voltage per bridge. The switches can be switched at zero voltage switching (ZVS) and/or zero current switching (ZCS). Accordingly, switching losses are reduced, and the power efficiency is increased.
Figure 2 presents a block diagram for a typical EV UFC that involves an AC-DC stage and a DC-DC stage. This paper will focus on the DC-DC stage employed in EV UFC applications. In the literature, many research studies have been introduced the two stages. In [21], to realize medium-voltage EV UFC stations, a multiport power converter has been proposed. In [22], a bidirectional fast charging system control strategy consisting of two cascaded stages has been proposed, where two DABs are connected in parallel at the battery side. However, in [23], an isolated DAB-based single-stage AC-DC converter has been presented. The charger in [23] contains a single stage that includes the PFC and ensures ZVS over the full load range. In [24,25], a frequency modulated CLLC-R-DAB has been proposed. In this topology, the converter operates over a considerable variation of the input voltage while maintaining soft-switching capability. A smaller switching frequency range is used to modulate the CLLC-R-DAB converter when compared to SR-DAB. In [26], a full-bridge phase-shifted DC-DC converter that combines the characteristics of the double inductor rectifier and the conventional hybrid switching converter is introduced for EV fast chargers. In [27], a medium-voltage high-power isolated DC-DC converter for EVs fast chargers is presented. In [28], the AC-DC and DC-DC stages of an EV charger are studied where the DC-DC stage utilizes interleaved DC-DC converters.
Multimodule converters are considered a suitable choice for realizing the high power and high voltage requirements of the UFC charger. However, an increased number of modules with low power would increase system complexity, cost and losses, which reduces the cooling requirements and consequently the weight, volume, and cost. However, reduced switching losses can be achieved via soft-switching [29,30,31,32,33,34,35]. Nonetheless, introducing a low number of modules with high power would reduce the switching frequency capabilities; therefore, reducing the power density, which increases size and weight.
Accordingly, the main contribution of this work is to introduce a hybrid multimodule DC-DC converter-based DAB topology as the DC-DC stage for EV UFC to achieve high efficiency, high power density, and reduced weight and cost. The hybrid concept is achieved through employing two different groups of multimodule converters. The first group is designed to be in charge of a high fraction of the total required power while operating relatively at a low switching frequency. Nevertheless, the second group is designed for a low fraction of the total power operating relatively at a high switching frequency. The work presented in this paper includes a generalized small-signal model for the presented converter as well as the control strategy required in achieving uniform power-sharing between the employed modules. Besides, a power loss evaluation has been conducted to compare the proposed converter with the other two options.
To verify the presented concept, the number of modules needed to achieve the required ratings is calculated for both; conventional multimodule DC-DC converters and hybrid multimodule DC-DC converters. In addition, the power loss analysis of the hybrid multimodule converter is provided. To support the power converter controller design, a generalized small-signal model for the hybrid multimodule DC-DC converter is studied in detail. Besides, to ensure equal power-sharing among the employed modules, the control scheme for the hybrid multimodule DC-DC converter with the aforementioned specifications is studied. The main contribution of the paper can be summarized as follows:
  • Development of a hybrid multimodule DC-DC converter-based DAB topology for EV UFC along with providing generalized small-signal modeling to support the design of the power converter controller. The presented generalized small-signal model of the hybrid multimodule DC-DC converter-based DAB is considered as the primary contribution of this paper.
  • Examining the cross feedback output current sharing (CFOCS) for the hybrid Input-series output-parallel (ISOP) multimodule power converters to ensure uniform power-sharing among the employed modules and ensure the desired fraction of power handled by each multimodule group.
This paper is structured as follows: Section 2 presents the hybrid input-series input-parallel output-series output-parallel (ISIP-OSOP) multimodule power converter and the generalized small-signal modeling. Section 3 presents a 200   kW hybrid eight-module ISOP converter. In Section 3, the small-signal model of the presented converter is derived using the analysis provided in Section 2. Section 4 presents the number of modules needed to achieve the required ratings for both; conventional multimodule DC-DC converters and hybrid multimodule DC-DC converters. In addition, the power loss analysis of the conventional and hybrid multimodule converters is provided. Section 5 discusses the control strategy for the proposed hybrid ISOP multimodule DC-DC converters. Section 6 discusses the MatLab/Simulink model and the simulation results. Finally, Section 7 summarizes the key findings of this paper.

2. Generalized Small-Signal Analysis for Dual Series/Parallel Input-Output (ISIP-OSOP) Hybrid Multimodule Converters

In this section, the generalized small-signal modeling for dual series/parallel ISIP-OSOP hybrid multimodule DC-DC converter is introduced.

2.1. Hybrid ISIP-OSOP Generic DC-DC Converter Circuit Configuration

The hybrid ISIP-OSOP generic DC-DC converter configuration, shown in Figure 3, consists of n modules that are connected in series and/or parallel at the input side and in series and/or parallel at the output side. These n modules consist of two different multimodule groups. The primary group consists of L isolated DC-DC converters that are in charge of a high fraction of the total required power operating relatively at a low switching frequency. The secondary group consists of M isolated DC-DC converters that are designed for a small fraction of the total power operating relatively at a high switching frequency. Accordingly, it can be said that the summation of L and M power converters results in a total of n DAB units. To differentiate between the primary and secondary multimodule DC-DC converter in the small signal analysis, the set of equations representing the primary group is black colored while the set of equations representing the secondary group is blue colored. In addition, the red colored symbols reflect the parameters defined for the input side, while the blue colored symbols reflects the parameters defined for the output side, as presented in the following.
By ensuring input current sharing (ICS) and input voltage sharing (IVS) for the primary group, the input current for each module in the primary group is reduced to I i n L α L 1 , and the input voltage for each module in the primary group is reduced to V i n L β L 1 . However, by ensuring ICS and IVS for the secondary group, the input current for each module in the secondary group is reduced to I i n M α M 1 , and the input voltage for each module in the secondary group is reduced to V i n M β M 1 group is reduced to V i n M β M 1 , in which, I i n L and V i n L are the input current and the input voltage for the primary group that consists of L number of modules, respectively. I i n M and V i n M are the input current and the input voltage for the secondary group that consists of M number of modules, respectively. α M 1 represents the number of modules connected in parallel in the secondary group at the input side.   β M 1 represents the number of modules connected in series the secondary group at the input side.
Similarly, by ensuring output current sharing (OCS) and output voltage sharing (OVS) for the primary group, the output current per module in the primary group is I o L a L 1 , and the output voltage per module in the primary module is reduced to V o L b L 1 . However, by ensuring OCS and OVS for the secondary group, the output current per module is I o M a M 1 , and the output voltage for each module in the secondary group is reduced to V o M b M 1 . In which, I o L and V o L are the output current and the output voltage for the primary group that consists of L number of modules, respectively. I o M and V o M are the output current and the output voltage for the secondary group that consists of M number of modules, respectively. a M 1 represents the number of modules connected in parallel in the secondary group at the output side. b M 1 represents the number of modules connected in series in the secondary group at the output side.
The L isolated modules are responsible for delivering a portion of K L of the total required power, while the M isolated modules are responsible for delivering a portion of K M of the total required power, where K L + K M = 1 pu. The input voltages, input currents, output currents, and output voltages are represented in terms of the total input voltage, total input current, total output voltage, and total output current would result in Table 1.

2.2. Hybrid ISIP-OSOP DC-DC Converter Small-Signal Modeling

Using the model in [36], and expanding the study of the multimodule DC-DC converters in [37,38,39,40,41], the small-signal model for the hybrid multimodule ISIP-OSOP converter shown in Figure 4 is derived. Since each group is responsible for delivering a particular portion of the overall required power, where this portion is defined according to the overall system power ratings. Accordingly, it is worth mentioning that the equivalent load resistance seen by each group of multimodule converters is different.
Since the input current and input voltage for each module in the primary group are α L 2   I i n α L 1 and β L 2   V i n β L 1 , respectively, and the output current and output voltage for each module in the primary group are a L 2 I o a L 1 and b L 2 V o b L 1 , respectively. Therefore, the load resistance for each module in the primary group is a L 1 b L 2 a L 2 b L 1 R . Accordingly, d ^ i j L , d ^ v L j which are the effect of changing the filter inductor current and the effect of changing the input voltage on the duty cycle modulation for the primary group and I e q L presented in Figure 4 can be defined as:
d ^ i L j = 4 β L 1 L l k L f s L β L 2   K 1 V i n i ^ L L j ,   j = 1 , 2 , , L
Equation (1) can be written as:
d ^ i L j = β L 1 K 1 R d L β L 2   V i n i ^ L L j ,   j = 1 , 2 , , L
where R d L = 4 L l k L f s L K 1 2 .
d ^ v L j = 4 a L 2 b L 1 β L 1 L l k L f s L D e f f 1 a L 1 b L 2 β L 2   K 1 2 R V i n v ^ c d L j ,   j = 1 , 2 , , L
Equation (3) can be written as:
d ^ v L j = a L 2 b L 1 β L 1 R d L D e f f 1 a L 1 b L 2 β L 2   R V i n v ^ c d L j ,   j = 1 , 2 , , L
I e q L = a L 2 b L 1 β L 2 V i n a L 1 b L 2 β L 1   K 1 R
Since the input current and input voltage for each module in the primary group is α M 2   I i n α M 1 and β M 2   V i n β M 1 , respectively, and the output current and output voltage for each module in the primary group is   a M 2 I o a M 1 and b M 2 V o b M 1 , respectively. Therefore, the load resistance for each module in the primary group is a M 1 b M 2 a M 2 b M 1 R . Accordingly, d ^ i j M , d ^ v M j which are the effect of changing the filter inductor current and the effect of changing the input voltage on the duty cycle modulation for the primary group and I e q M presented in Figure 4 can be defined as:
d ^ i M j = 4 β L 1 L l k M f s M β L 2   K 2 V i n i ^ L M j ,   j = 1 , 2 , ,   M
Equation (6) can be written as:
d ^ i M j = β L 1 K 2 R d M β L 2   V i n i ^ L M j ,   j = 1 , 2 , , M
where; R d M = 4 L l k M f s M K 2 2 .
d ^ v M j = 4 a L 2 b L 1 β L 1 L l k M f s M D e f f 2 a L 1 b L 2 β L 2   K 2 2 R V i n v ^ c d M j ,   j = 1 , 2 , ,   M
Equation (8) can be written as:
d ^ v M j = a L 2 b L 1 β L 1 R d M D e f f 2 a L 1 b L 2 β L 2   R V i n v ^ c d M j ,   j = 1 , 2 , ,   M
I e q M = a L 2 b L 1 β L 2 V i n a L 1 b L 2 β L 1   K 2 R
Based on the feature of modularity and to simplify the analysis, it is assumed that all modules in the primary group and all modules in the secondary group have an equal effective duty cycle, transformer turns ratio, capacitor, and inductor values. Accordingly, K L 1 = K L 2 = = K L L = K 1 , K M 1 = K M 2 = = K M M = K 2 C L 1 = C L 2 = = C L L = C L ,   C M 1 = C M 2 = = C M M = C M , C d L 1 = C d L 2 = = C d L L = C d L , C d M 1 = C d M 2 = = C d M M = C d M , L L 1 = L L 2 = = L L L = L L and L M 1 = L M 2 = = L M M = L M . In addition, it is also assumed that all modules in the primary group share the same input voltage and that all modules in the secondary group share the same input voltage. Accordingly, the DC input voltage of each module in the primary group is β L 2   V i n β L 1 and the DC input voltage of each module in the secondary group is β M 2   V i n β M 1 . Although each module has a different duty cycle perturbation, it is assumed that all the DAB units have an equal normalized time shift. Besides, the ESR of the output capacitance is considered in this model. However, the ESR can be neglected compared to the load.
The following equations are obtained from Figure 4:
{ D e f f 1 K 1 v ^ c d L 1 + β L 2   V i n β L 1   K 1 ( d ^ i L 1 + d ^ v L 1 + d ^ L 1 ) = s L L i ^ L L 1 + v ^ o u t L 1 D e f f 1 K 1 v ^ c d L 2 + β L 2   V i n β L 1   K 1 ( d ^ i L 2 + d ^ v L 2 + d ^ L 2 ) = s L L i ^ L L 2 + v ^ o u t L 2 D e f f 1 K 1 v ^ c d L L + β L 2   V i n β L 1   K 1 ( d ^ i L L + d ^ v L L + d ^ L L ) = s L L i ^ L L L + v ^ o u t L L D e f f 2 K 2 v ^ c d M 1 + β L 2   V i n β L 1   K 2 ( d ^ i M 1 + d ^ v M 1 + d ^ M 1 ) = s L M i ^ L M 1 + v ^ o u t M 1 D e f f 2 K 2 v ^ c d M 2 + β L 2   V i n β L 1   K 2 ( d ^ i M 2 + d ^ v M 2 + d ^ M 2 ) = s L M i ^ L M 2 + v ^ o u t M 2 D e f f 2 K 2 v ^ c d M M + β L 2   V i n β L 1   K 2 ( d ^ i M M + d ^ v M M + d ^ M M ) = s L M i ^ L M M + v ^ o u t M M
{ i ^ L L 11 + i ^ L L 21 + + i ^ L L a L 1 1 = s C L s R c L C L + 1 v ^ o u t L 1   + v ^ o u t L R i ^ L L 12 + i ^ L L 22 + + i ^ L L a L 1 2 = s C L s R c L C L + 1 v ^ o u t L 2   + v ^ o u t L R i ^ L L 1 b L 1 + i ^ L L 2 b L 1 + + i ^ L L a L 1 b L 1 = s C L s R c L C L + 1 v ^ o u t L L   + v ^ o u t L R i ^ L M 11 + i ^ L M 21 + + i ^ L M a M 1 1 = s C M s R c M C M + 1 v ^ o u t M 1   + v ^ o u t M R i ^ L M 12 + i ^ L M 22 + + i ^ L M a M 1 2 = s C M s R c M C M + 1 v ^ o u t M 2   + v ^ o u t M R i ^ L M 1 b L 1 + i ^ L M 2 b L 1 + + i ^ L M a M 1 b L 1 = s C M s R c M C M + 1 v ^ o u t M M   + v ^ o u t M R
Adding equations representing the primary multimodule group in (12):
i = 1 a L 1 j = 1 b L 1 i ^ L L i j = s C L s R c L C L + 1 v ^ o u t L + b L 1 v ^ o u t L R
Equation (13) can be written as:
i = 1 a L 1 j = 1 b L 1 i ^ L L i j = v ^ o u t L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) )
Adding equations representing the secondary multimodule group in (12):
i = 1 a M 1 j = 1 b M 1 i ^ L M i j = s C M s R c M C M + 1 v ^ o u t M + b M 1 v ^ o u t M R
Equation (15) can be written as:
i = 1 a M 1 j = 1 b M 1 i ^ L M i j = v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) )
Defining the summation terms of the module’s input and output voltage appearing after summing up equations representing the primary multimodule group in (11):
j = 1 L v ^ c d L j = γ L v ^ i n L = γ L β L 2 v ^ i n
where:
  • γ L = 1 , if all the modules in the primary group at the input side are connected in series.
  • γ L = α L 1 , if all the modules in the primary group at the input side are connected in parallel or connected in both series and parallel.
j = 1 L v ^ o u t L j = c L v ^ o u t L = c L b L 2 v ^ o u t
where:
  • c L = 1 , if all the modules in the primary group at the output side are connected in series.
  • c L = a L 1 , if all the modules in the primary group at the output side are connected in parallel or connected in both series and parallel.
Defining the summation terms of the module’s input and output voltage appearing after summing up equations representing the secondary multimodule group in (11):
j = 1 M v ^ c d M j = γ M v ^ i n M = γ M β M 2 v ^ i n
where:
  • γ M = 1 , if all the modules in the secondary group at the input side are connected in series.
  • γ M = α L 1 , if all the modules in the secondary group at the input side are connected in parallel or connected in both series and parallel.
j = 1 M v ^ o u t M j = c M v ^ o u t L = c M b M 2 v ^ o u t
where:
  • c M = 1 , if all the modules in the secondary group at the output side are connected in series.
  • c M = a M 1 , if all the modules in the secondary group at the output side are connected in parallel or connected in both series and parallel.

2.2.1. Control-to-Output Voltage Transfer Function

The relation between the output voltage and the duty cycle is obtained by performing two steps. The first step is by adding the L equations in (11) to obtain the relation between v ^ o u t L and d ^ L j , assuming v ^ i n L = 0 , and d ^ L k = 0 , where k = 1 ,   2 , ,   L and k j , and substituting (2), (4), (14), (17) and (18). However, the second step is by adding the M equations in (11) to obtain the relation between v ^ o u t M and d ^ M j , assuming v ^ i n M = 0 , and d ^ M k = 0 , where k = 1 ,   2 , ,   L and k j , and substituting (7), (9), (16), (19) and (20).
Adding the L equations in (11) would result in:
D e f f 1 K 1 j = 1 L v ^ c d L j + β L 2   V i n β L 1   K 1 ( j = 1 L d ^ i L j + j = 1 L d ^ v L j + j = 1 L d ^ L j ) = s L L j = 1 L i ^ L L j + j = 1 L v ^ o u t L j
Substituting (2), (4) and (14) would result in:
D e f f 1 K 1 j = 1 L v ^ c d L j + β L 2   V i n β L 1   K 1 ( β L 1 K 1 R d L β L 2   V i n v ^ o u t L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) + j = 1 L a L 2 b L 1 β L 1 R d L D e f f 1 a L 1 b L 2 β L 2   R V i n v ^ c d L j + d ^ L 1 )           = s L L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) v ^ o u t L + j = 1 L v ^ o u t L j
Substituting (17) and (18) in (22) results in:
D e f f 1 K 1 γ L v ^ i n L + β L 2   V i n β L 1   K 1 ( β L 1 K 1 R d L β L 2   V i n v ^ o u t L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) + a L 2 b L 1 β L 1 R d L D e f f 1 a L 1 b L 2 β L 2   R V i n γ L v ^ i n L + d ^ L 1 ) = s L L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) v ^ o u t L + c L v ^ o u t L
Simplifying (23) results in (24):
G v d L = v ^ o u t L d ^ L j = β L 2   V i n β L 1   K 1 ( 1 + s R c L C L ) s 2 L L C L ( 1 + b L 1 R c L R ) + s ( b L 1 L L R + R d L C L ( 1 + b L 1 R c L R ) + c L R c L C L ) + b L 1 R d L R + c L
Performing the second step which is adding the M equations in (11) to obtain the relation between v ^ o u t M and d ^ M j , assuming v ^ i n M = 0 , and d ^ M k = 0 , where k = 1 ,   2 ,   , M , and k j , and substituting (7), (9), (16), (19) and (20) would result in:
Adding the M equations in (11) would result in:
D e f f 2 K 2 j = 1 M v ^ c d M j + β M 2   V i n β M 1   K 2 ( j = 1 M d ^ i M j + j = 1 M d ^ v M j + j = 1 M d ^ M j ) = s L M j = 1 M i ^ L M j + j = 1 M v ^ o u t M j
Substituting (7), (9) and (16) would result in:
D e f f 2 K 2 + β M 2   V i n β M 1   K 2 ( β M 1 K 2 R d M β M 2   V i n v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) + j = 1 M a M 2 b M 1 β M 1 R d M D e f f 2 a M 1 b M 2 β M 2   R V i n v ^ c d M j + d ^ M 1 ) = s L M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) v ^ o u t M + j = 1 M v ^ o u t M j
Substituting (19) and (20) results in:
D e f f 2 K 2 γ M v ^ i n M + β M 2   V i n β M 1   K 2 ( β M 1 K 2 R d M β M 2   V i n v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) + a M 2 b M 1 β M 1 R d M D e f f 2 a M 1 b M 2 β M 2   R V i n γ M v ^ i n M + d ^ M 1 ) = s L M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) v ^ o u t M + c M v ^ o u t M
Simplifying (27) would result in (28).
G v d M = v ^ o u t M d ^ M j = β M 2   V i n β M 1   K 2 ( 1 + s R c M C M ) s 2 L M C M ( 1 + b M 1 R c M R ) + s ( b M 1 L M R + R d M C M ( 1 + b M 1 R c M R ) + c M R c M C M ) + b M 1 R d M R + c M
By adding G v d L and G v d M the control-to-output voltage transfer function can be found.

2.2.2. Control-to-Filter Inductor Current Transfer Function

The relation between the filter inductor current and the duty cycle is derived by performing two steps, where the first step considers the L modules in (11) while the second step considers the M modules in (11). The first step is by substituting v ^ o u t L in terms of i ^ L L j using (14) in (23) and assuming v ^ i n L = 0 , and d ^ L k = 0 , where k = 1 ,   2 , ,   L and k j . However, the second step is by substituting v ^ o u t M in terms of i ^ L M j using (16) in (27) and assuming v ^ i n M = 0 , and d ^ M k = 0 , where k = 1 ,   2 , ,   M and k j .
Substituting v ^ o u t L in terms of i ^ L L j using (14) in (23):
D e f f 1 K 1 γ L v ^ i n L + β L 2   V i n β L 1   K 1 ( β L 1 K 1 R d L β L 2   V i n   i = 1 a L 1 j = 1 b L 1 i ^ L L i j + a L 2 b L 1 β L 1 R d L D e f f 1 a L 1 b L 2 β L 2   R V i n γ L v ^ i n L + d ^ L 1 ) = s L L i = 1 a L 1 j = 1 b L 1 i ^ L L i j + c L ( R ( 1 + s R c L C L ) s R C L + s b L 1 R c L C L + b L 1 ) i = 1 a L 1 j = 1 b L 1 i ^ L L i j
β L 2   V i n β L 1   K 1 d ^ L 1 R d L j = 1 L i ^ L L j = s L L j = 1 L i ^ L L j + c L ( R ( 1 + s R c L C L ) s R C L + s b L 1 R c L C L + b L 1 ) j = 1 L i ^ L L j
Simplifying (30) would result in (31).
G i d L = j = 1 L i ^ L L j d ^ L j = β L 2   V i n β L 1   K 1 ( s R C L + s b L 1 R c L C L + b L 1 ) R ( s 2 L L C L ( 1 + b L 1 R c L R ) + s ( b L 1 L L R + R d L C L ( 1 + b L 1 R c L R ) + c L R c L C L ) + b L 1 R d L R + c L )
Performing the second step which is substituting v ^ o u t M in terms of i ^ L M j using (16) in (27) and assuming v ^ i n M = 0 , and d ^ M k = 0 , where k = 1 ,   2 , ,   M and k j would result in:
D e f f 2 K 2 γ M v ^ i n M + β M 2   V i n β M 1   K 2 ( β M 1 K 2 R d M β M 2   V i n   i = 1 a M 1 j = 1 b M 1 i ^ L M i j + a M 2 b M 1 β M 1 R d M D e f f 2 a M 1 b M 2 β M 2   R V i n γ M v ^ i n M + d ^ M 1 ) = s L M i = 1 a M 1 j = 1 b M 1 i ^ L M i j + c M ( R ( 1 + s R c M C M ) s R C M + s b M 1 R c M C M + b M 1 ) i = 1 a M 1 j = 1 b M 1 i ^ L M i j
β M 2   V i n β M 1   K 2 d ^ M 1 R d M j = 1 M i ^ L M j = s L M j = 1 M i ^ L M j + c M ( R ( 1 + s R c M C M ) s R C M + s b M 1 R c M C M + b M 1 ) j = 1 M i ^ L M j
Simplifying (33) would result in (34). By adding G i d L and G i d M , the control-to-filter inductor current transfer function can be found.
G i d M = j = 1 M i ^ L M j d ^ M j = β M 2   V i n β M 1   K 2 ( s R C M + s b M 1 R c M C M + b M 1 ) R ( s 2 L M C M ( 1 + b M 1 R c M R ) + s ( b M 1 L M R + R d M C M ( 1 + b M 1 R c M R ) + c M R c M C M ) + b M 1 R d M R + c M )
By adding G i d L and G i d M the control-to-output filter inductor current transfer function can be found.

2.2.3. Output Impedance

The generalized converter output impedance for the hybrid ISIP-OSOP multimodule DC-DC converter can be found by considering two groups of equations. The primary group is the L number of KCL equations presented in (12). However, the secondary group is the M number of KCL equations presented in (12).
To find the generalized converter output impedance, the KCL equation in (12) can be rewritten as follows:
{ i ^ L L 11 + i ^ L L 21 + + i ^ L L a L 1 1 + i ^ o u t L = g L v ^ o u t L 1   + v ^ o u t L R i ^ L L 12 + i ^ L L 22 + + i ^ L L a L 1 2 + i ^ o u t L = g L v ^ o u t L 2   + v ^ o u t L R i ^ L L 1 b L 1 + i ^ L L 2 b L 1 + + i ^ L L a L 1 b L 1 + i ^ o u t L = g L v ^ o u t L L   + v ^ o u t L R i ^ L M 11 + i ^ L M 21 + + i ^ L M a M 1 1 + i ^ o u t M = g M v ^ o u t M 1   + v ^ o u t M R i ^ L M 12 + i ^ L M 22 + + i ^ L M a M 1 2 + i ^ o u t M = g M v ^ o u t M 2   + v ^ o u t M R i ^ L M 1 b L 1 + i ^ L M 2 b L 1 + + i ^ L M a M 1 b L 1 + i ^ o u t M = g M v ^ o u t M M   + v ^ o u t M R
where; g L = s C L s R c L C L + 1 and g M = s C M s R c M C M + 1 .
Accordingly, the KCL equation in (14) can be modified as follows:
i = 1 a L 1 j = 1 b L 1 i ^ L L i j + i ^ o u t L = v ^ o u t L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) )
The relationship between the output voltage and the output current for the L modules is obtained by adding the L equations in (11), assuming v ^ i n L = 0 , and d ^ L j = 0 ,   j = 1 , 2 , , L , and substituting (2), (4), (17), (18) and (36).
D e f f 1 K 1 γ L v ^ i n L + β L 2   V i n β L 1   K 1 ( β L 1 K 1 R d L β L 2   V i n ( v ^ o u t L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) i ^ o u t L ) + a L 2 b L 1 β L 1 R d L D e f f 1 a L 1 b L 2 β L 2   R V i n γ L v ^ i n L + d ^ L 1 ) = s L L ( ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) v ^ o u t L i ^ o u t L ) + c L v ^ o u t L
R d L ( v ^ o u t L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) i ^ o u t L ) = s L L ( ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) v ^ o u t L i ^ o u t L ) + c L v ^ o u t L
Simplifying (38) would result in (39).
Z o u t L = v ^ o u t L i ^ o u t L = b L 1 ( R d L + s L L ) ( 1 + s R c L C L ) s 2 L L C L ( 1 + b L 1 R c L R ) + s ( b L 1 L L R + R d L C L ( 1 + b L 1 R c L R ) + c L R c L C L ) + b L 1 R d L R + c L
Similarly, the KCL equation in (16) can be modified as follows:
i = 1 a M 1 j = 1 b M 1 i ^ L M i j + i ^ o u t M = v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) )
The relationship between the output voltage and the output current for the M modules is derived by summing the M equations in (11), assuming v ^ i n M = 0 , and d ^ M j = 0 , j = 1 , 2 , , M , and substituting (7), (9), (19), (20) and (40).
D e f f 2 K 2 γ M v ^ i n M + β M 2   V i n β M 1   K 2 = ( β M 1 K 2 R d M β M 2   V i n ( v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) i ^ o u t M ) + a M 2 b M 1 β M 1 R d M D e f f 2 a M 1 b M 2 β M 2   R V i n γ M v ^ i n M + d ^ M 1 )
s L M ( ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) v ^ o u t M i ^ o u t M ) + c M v ^ o u t M R d M ( v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) i ^ o u t M ) = s L M ( ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) v ^ o u t M i ^ o u t M ) + c M v ^ o u t M
Simplifying (42) would result in (43):
Z o u t M = v ^ o u t M i ^ o u t M = b M 1 ( R d M + s L M ) ( 1 + s R c M C M ) s 2 L M C M ( 1 + b M 1 R c M R ) + s ( b M 1 L M R + R d M C M ( 1 + b M 1 R c M R ) + c M R c M C M ) + b M 1 R d M R + c M
By adding Z o u t L and Z o u t M , the output impedance transfer function can be found.

2.2.4. Converter Gain

The generalized relationship between the output voltage and the input voltage of the hybrid ISIP-OSOP DC-DC converter can be found by performing two steps. The first step is adding the L number of KVL equations presented in (11) for the primary multimodule DC-DC converters, assuming d ^ L j = 0 ,   j = 1 , 2 , , L , and substituting (2), (4), (14), (17) and (18) in the added equation. However, the second step is adding the M number of KVL equations presented in (11) for the secondary multimodule DC-DC converters, assuming d ^ M j = 0 ,   j = 1 , 2 , , M , and substituting (7), (9), (16), (19) and (20) in the added equation.
Adding the L number of KVL equations in (11), assuming d ^ L j = 0 ,   j = 1 , 2 , , L , and substituting (2), (4) and (14) would result in:
D e f f 1 K 1 j = 1 L v ^ c d L j + β L 2   V i n β L 1   K 1 ( β L 1 K 1 R d L β L 2   V i n v ^ o u t L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) + j = 1 L a L 2 b L 1 β L 1 R d L D e f f 1 a L 1 b L 2 β L 2   R V i n v ^ c d L j ) = s L L ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) v ^ o u t L + j = 1 L v ^ o u t L j
Substituting (17) and (18) in (44) would give:
D e f f 1 K 1 γ L ( 1 + a L 2 b L 1 R d L a L 1 b L 2 R ) v ^ i n L = ( s L L + R d L ) ( ( s R C L + s b L 1 R c L C L + b L 1 R ( 1 + s R c L C L ) ) v ^ o u t L ) + c L v ^ o u t L
Simplifying (45) would result in (46):
G v g L = v ^ o u t L v ^ i n L = D e f f 1 K 1 γ L ( 1 + a L 2 b L 1 R d L a L 1 b L 2 R ) ( 1 + s R c L C L ) s 2 L L C L ( 1 + b L 1 R c L R ) + s ( b L 1 L L R + R d L C L ( 1 + b L 1 R c L R ) + c L C L ) + b L 1 R d L R + c L
Similarly, Adding the M number of KVL equations in (11), assuming d ^ M j = 0 ,   j = 1 , 2 , , M , and substituting (7), (9) and (16) would result in:
D e f f 2 K 2 j = 1 M v ^ c d M j + β M 2   V i n β M 1   K 2 ( β M 1 K 2 R d M β M 2   V i n v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) + j = 1 M a M 2 b M 1 β M 1 R d M D e f f 2 a M 1 b M 2 β M 2   R V i n v ^ c d M j + d ^ M 1 ) = s L M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) v ^ o u t M + j = 1 M v ^ o u t M j
Substituting (19) and (20) in (47) would give:
D e f f 2 K 2 γ M ( 1 + a M 2 b M 1 R d M a M 1 b M 2 R ) v ^ i n M + c M v ^ o u t M ( β M 1 K 2 R d M β M 2   V i n v ^ o u t M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) + j = 1 M a M 2 b M 1 β M 1 R d M D e f f 2 a M 1 b M 2 β M 2   R V i n v ^ c d M j + d ^ M 1 ) = s L M ( s R C M + s b M 1 R c M C M + b M 1 R ( 1 + s R c M C M ) ) v ^ o u t M + j = 1 M v ^ o u t M j
Simplifying (48) would result in (49):
G v g M = v ^ o u t M v ^ i n M = D e f f 2 K 2 γ M ( 1 + a M 2 b M 1 R d M a M 1 b M 2 R ) ( 1 + s R c M C M ) s 2 L M C M ( 1 + b M 1 R d M R ) + s ( b M 1 L M R + R d M C M ( 1 + b M 1 R c M R ) + c M C M ) + b M 1 R d M R + c M
By adding G v g L and G v g M , the output impedance transfer function can be found.

3. Hybrid Input-Series Output-Parallel (ISOP) Multimodule DC-DC Converter

In this section, the hybrid ISOP multimodule power converter circuit diagram, as well as the hybrid ISOP multimodule converter small-signal analysis, are discussed. The analysis carried out in this section is not limited to unidirectional power flow and can be applied for bidirectional power flow. The generalized small-signal modeling presented in Section 2 is used to derive the small-signal model for the eight-module hybrid ISOP power converter.

3.1. ISOP Circuit Diagram

The conventional ISOP converter shown in Figure 5a consists of multiple DAB units that are connected in series and in parallel at the input and the output sides, respectively, where all the modules are assumed identical. However, the concept of the hybrid ISOP power converter shown in Figure 5b is dividing conventional ISOP multimodule DC-DC converters into two groups. The primary group consists of identical ISOP DC-DC converters and is responsible for delivering a large portion of the total required power with lower switching frequency. This is shown in Figure 5c. However, the secondary group consists of another identical ISOP multimodule DC-DC converters. It is responsible for delivering the remaining power with higher switching frequency. This is shown in Figure 5d. This would result in two groups of multimodule converters operating at a different switching frequency, and utilizing different leakage inductance, transformers, filter inductors, and capacitors.
In this paper, the EV UFC specifications are assumed to deliver a total power of 200   kW using a battery voltage of 400   V , and assuming a grid voltage of 10   kV . It is assumed that the primary group handles 80 % of the total battery charging power, while the secondary group handles 20 % of the total battery charging power. Therefore, the primary group is responsible for delivering 160   kW , which 4 5 of the total required power. The primary group is assumed to operate at switching frequency f s L of 10   kHz . However, the secondary group is responsible for delivering the remaining 40   kW , which is 1 5 of the total required power. The secondary group is assumed to operate at switching frequency of f s M 100   kHz . Accordingly, the input voltage of the primary group V i n L is 8   kV , which is 4 5 of the total input voltage V i n , while the input voltage of the secondary group V i n M is 2   kV , which is 1 5 of the total input voltage V i n . Similarly, the output current of the primary group I o L is 400   A , which is 4 5 of the total output current I o u t , while the output current of the secondary group I o M is 100   A , which is 1 5 of the total output current I o u t . It is essential to mention that the portions 4 5 and 1 5 are denoted as K L and K M , respectively.
By ensuring equal IVS for the primary group and secondary group, the input voltage per module in the primary group is reduced to V i n L 4 , while the input voltage per module in the secondary group is V i n M 4 . Besides, by ensuring equal OCS for the primary and secondary group, the output current of each module in the primary group is reduced to I o L 4 , while the output current of each module in the secondary group is reduced to I o M 4 . In which, V i n L , V i n M ,   I o L , and I o M are the input voltages and output currents of the primary group and secondary group, respectively.

3.2. Hybrid ISOP Small Signal Analysis

The eight-module hybrid ISOP converter small-signal model shown in Figure 6 is derived using [36]. The generalized model derived in the previous section is used to derive the small-signal functions for the presented converter in Figure 6, as shown in Table 2. The presented transfer functions are used in the control strategy scheme presented in the power balancing section.

4. Efficiency and Power Density Assessment of the Hybrid Multimodule DC-DC Converter

4.1. Efficiency Assessment

According to the presented ratings of the DAB units, the primary group utilizes power modules that are rated at 40   kW while the secondary group utilizes power modules that are rated at 10   kW . Accordingly, to realize the total desired power, relying only on the secondary group would result in a total number of 20 modules. However, relying on the primary group would result in a total number of five modules. Therefore, it can be said that the primary group results in a lower number of modules but has a limitation in terms of the switching frequency, while the secondary group results in a higher number of modules but with higher switching capability. On the other hand, applying the presented concept would result in a total number of eight modules. Table 3 presents a comparison between the three concepts in terms of the number of employed modules as well as power, voltage, and current ratings.
The converter efficiency can be presented as in (50):
η = P i n P t P i n
where, P t represents the total losses in the employed converter. The semiconductor devices’ losses include two types; conduction and switching losses. It is worth mentioning that the following analysis is carried out considering MOSFETs for low power modules and IGBTs for high power modules. The semiconductor conduction losses of the primary and secondary sides can be obtained using the RMS switch currents I S 1 , R M S and I S 2 , R M S , respectively with the primary and secondary drain-to-source resistances R D S 1 and R D S 2 in case of using MOSFETs. The RMS switch currents can be found from the RMS inductor current as follows [42]:
I S 1 , R M S = I L , R M S 2 I S 2 , R M S = n I L , R M S 2
The conduction losses of the primary and secondary sides power switches can be represented as:
P S 1 , C o n d . = 4 ( I S 1 , R M S ) 2 R D S 1 P S 2 , C o n d . = 4 ( I S 2 , R M S ) 2 R D S 2
In case of using IGBTs, the conduction losses can be obtained using the collector-to-emitter voltage V C E ( S a t ) , average IGBT current I I G B T and the duty cycle D . The conduction losses of the primary and secondary IGBTs can be represented as follows:
P S 1 , C o n d . = 4 V C E ( S a t ) I I G B T 1 D P S 2 , C o n d . = 4 V C E ( S a t ) I I G B T 2 D
The modulation schemes derived and presented in [29] allow the DAB power converter to operate under ZVS throughout the entire period. Hence the switching losses of the employed power devices can be neglected, assuming that the converter is operating under ZVS [42,43,44,45].
The aforementioned power losses are the conduction losses of only one DAB unit. However, the presented converter has a hybrid modular structure, meaning that Equations (52) and (53) are modified according to the configuration of the proposed multimodule converter to include the primary and secondary groups consisting of L and M isolated modules, respectively. Therefore, Equations (52) and (53) are modified to include the conduction losses in the IGBTs and MOSFETs for multiple numbers of DAB units, as shown in (54) and (55). The primary-side conduction losses of the hybrid multimodule converter include the conduction losses in the IGBTs and the conduction losses in the MOSFETs for L and M modules, respectively, and can be represented as follows:
P S 1 , C o n d . = 4 L V C E ( S a t ) I I G B T 1 D + 4 M ( I S 1 , R M S ) 2 R D S 1
where, I S 1 , R M S = I L M , R M S 2 .
Similarly, the secondary-side conduction losses can be represented as follows:
P S 2 , C o n d . = 4 L V C E ( S a t ) I I G B T 2 D + 4 M ( I S 2 , R M S ) 2 R D S 2
where, I S 2 , R M S = n I L M , R M S 2 .
To evaluate the losses associated with the hybrid ISOP DC-DC converter and compare it with conventional multimodule DC-DC converter relying on the secondary group and conventional multimodule relying on the primary group, Equations (52)–(55) are used to calculate the conduction losses associated with the semiconductor devices. It is assumed that the turns ratio of the employed transformers is 1 : 1 and that the duty cycle is 0.5 with an RMS inductor current of 25   A for each module, where each converter is rated at 200   kW . The number of L and M modules is specified in Table 3 for the three converters. In the provided assessment, the device parameters of a SiC MOSFET CMF20120D with a drain-to-source resistance of 80   m Ω and the device parameters of an IGBT IKW25N120T2 with a collector-to-emitter voltage of 1.7   V are considered. Considering only the conduction losses of the switching devices in the three multimodule converters, the following can be observed. Conventional multimodule DC-DC converter relying on the secondary group and conventional multimodule DC-DC converter relying on the primary group would results in losses of 5.1   kW   (i.e., efficiency of 97.5 % ) and 680   W (i.e., efficiency of 99.6 % ), respectively. However, conduction losses in the hybrid multimodule DC-DC converter are found to be 1.6   kW ((i.e., efficiency of 99.2 % ). Figure 7 presents the efficiency loss curve with respect to power loading for the three converter systems.

4.2. Power Density Assessment

This subsection presents a rough estimation of the power density for the three converters presented in Table 3. The power density can be evaluated in terms of power losses and the volume of the converter components, as defined in (56). The total volume of the converter can be represented by summing up the volume of the utilized power switches, heat sinks, the transformer’s winding, and the transformer’s core as defined in (57) [46]:
ρ = P i n P t V o l u m e
V o l t = V o l s w + V o l H S + V o l C o r e + V o l W i n d i n g
The volume of the overall converters is evaluated, considering the study provided in [47,48]. In which it is assumed that the converter components contribute with the same percentage as presented in [48]. Based on the study provided in [47,48], the volume contribution for the converter components is presented in Figure 8 and Figure 9 considering hard switching and soft switching operation, respectively. It can be observed from Figure 8 that the volume of the heat sinks in the primary group multimodule DC-DC converter is almost the same as the volume of the heat sinks in the secondary group multimodule DC-DC converter. However, the volume of the transformer is higher in the primary group multimodule DC-DC converter due to the lower switching frequency. Accordingly, considering the losses for the three converters presented earlier, the power density of the conventional multimodule DC-DC converter relying on the secondary group is 12.2   kW / L , while the power density of the conventional multimodule DC-DC converter relying on the primary group is 9.9   kW / L . On the other hand, the power density in the hybrid multimodule DC-DC converter is found to be 10.3   kW / L .

5. Power-Sharing in the Eight-Module Hybrid ISOP Fast Charger DC-DC Converter

Since modules in practical applications are not identical, any mismatch in the parameter values can cause unequal power distribution among the modules. Consequently, the voltage of modules is unbalanced, which may cause heavy loading or thermal overstress [39]. Accordingly, a control scheme that ensures uniform power-sharing among the modules is required to achieve reliable operation for the hybrid ISIP-OSOP DC-DC converter.
Since the presented converter is connected in series and parallel at the input and output sides, respectively, a control scheme that ensures IVS and OCS is required. A control strategy for equal power-sharing among the modules is addressed for the eight-module hybrid ISOP DC-DC converter. In other words, a cross-feedback OCS (CFOCS) for ISOP has been presented in [49] to ensure both equal IVS and OCS. The OCS is achieved among the modules and automatically ensuring IVS without the need for an IVS control loop. The presented control strategy in [49] has a fault-tolerant feature even when introducing a mismatch in the module’s parameters. In addition, the output voltage regulation for the converter is simplified. The concept of this control strategy is based on applying the feedback control to be the summation of all the other current control loops instead of applying its own current feedback control loop.
In this paper, the CFOCS is applied to the presented hybrid ISOP converter to ensure uniform power-sharing where the system parameters are shown in Table 4. The OCS control, shown in Figure 10, consists of one outer output current loop and eight inner current loops where four are dedicated to the primary multimodule group, and the other four inner loops are dedicated to the secondary multimodule group. The control scheme, shown in Figure 10, for the eight-module hybrid ISOP converter is current-controlled considering a reflex charging technique that is termed as burp charging or negative pulse charging. The control scheme, presented in Figure 10, is tested with reference current relying on the burp charging algorithm to the output current reference signal. The charging cycle starts with a positive sequence from 0.2 s to 0.6 s. After that, a rest period for 0.1 s is applied, then a short discharge sequence for 0.1 s.

6. Discussion

A MatLab/Simulink model is simulated using the small-signal model derived in Section 3 along with the control strategy presented in Figure 10, where the parameter mismatch presented in Table 4 is introduced to the employed modules.
As can be observed from Figure 11, the control strategy for the proposed eight-module hybrid converter can accomplish the requirements. Results, presented in Figure 11, demonstrate that the controller in Figure 10 compensates for the negative influences resulting from the system parameters mismatch. In which the modular input voltages and the modular output currents are equally shared between the four modules. It can be seen from the presented results in Figure 11 that the primary multimodule group is in charge of delivering 4 5 of the total desired power while the secondary multimodule group is in charge of delivering 1 5 of the total desired power. Besides, the output current of the proposed power converter tracks the reference current that relies on the burp charging algorithm. Accordingly, it can be concluded that the applied control strategy is reliable and that equal power-sharing is achieved between the employed modules.

7. Conclusions

This paper introduces a hybrid multimodule DC-DC converter for EV UFC to achieve both high efficiency and high power density. The hybrid concept is achieved through employing two different groups of multimodule converters. The first is designed to be in charge of a high fraction of the total required power, operating relatively at a low switching frequency. While the second is designed for a small fraction of the total power, operating relatively at a high switching frequency. To support the power converter controller design, a generalized small-signal model for the hybrid multimodule DC-DC converter is studied in detail. This in turn supports the analysis and control design. In addition, the efficiency and power density for the conventional multimodule DC-DC converter based on the primary group, conventional multimodule DC-DC converter based on the secondary group as well as the presented hybrid DC-DC converter are evaluated. In which it has been shown that the presented converter can achieve both high efficiency ( 99.6 % ) and high power density ( 10.3   kW / L ), compromising between the two other conventional converters. Since the power switches are the key contributors to the losses and the volume of the overall converter. It is worth mentioning that the assessment provided in this paper takes into account the conduction losses and the volume of the semiconductor switches, assuming that the converters are operating under zero voltage switching (ZVS). Furthermore, cross feedback output current sharing (CFOCS) for the hybrid input-series output-parallel (ISOP) multimodule DC-DC converters to ensure uniform power-sharing among the employed modules and the desired fraction of power handled by each multimodule group is examined. The control scheme for a hybrid eight-module ISOP power converter of 200 kW is investigated. The controller is tested with a reference current that relies on reflex charging scheme. The power loss analysis of the hybrid multimodule converter is provided. Simulation results using the MatLab/Simulink platform are provided to elucidate the presented concept considering parameter mismatches. Simulation results show that the modular input voltage and the modular output current are equally shared among the four modules of each group with the required ratio between the two multimodule groups. Numerical calculation in terms of losses is carried out for the presented converter considering conduction losses of the power switches.

Author Contributions

M.E. and A.M. contributed to the whole research work and analysis tools; M.E. wrote the paper. This work was performed under the supervision with regular and continuous feedback of A.M. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by NPRP grant NPRP (10-0130-170286) from the Qatar National Research Fund (a member of Qatar Foundation).

Acknowledgments

This work was supported by NPRP grant NPRP (10-0130-170286) from the Qatar National Research Fund (a member of Qatar Foundation). The statements made herein are solely the responsibility of the authors.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

ICEsInternal Combustion Engines
EVsElectric Vehicles
UFCUltrafast Charging
DABDual Active Bridge
DHBDual Half Bridge
ZVSZZero Voltage Switching
CSCZero Current Switching
CFOCSCross Feedback Output Current Sharing
ISOPInput-Series Output-Parallel
ISIP-OSOPInput-Series Input-Parallel Output-Series Output-Parallel
ICSInput Current Sharing
IVSInput Voltage Sharing
OCSOutput Current Sharing
OVSOutput Voltage Sharing

References

  1. Chan, C.C. The State of the Art of Electric, Hybrid, and Fuel Cell Vehicles. Proc. IEEE 2007, 95, 704–718. [Google Scholar] [CrossRef]
  2. Wilson, J.R.; Burgh, G. Energizing Our Future: Rational Choices for the 21st Century; John Wiley & Sons Inc.: Hoboken, NJ, USA, 2008. [Google Scholar]
  3. Ehsani, M.; Gao, Y.; Gay, S.E.; Emadi, A. Modern Electric, Hybrid Electric, and Fuel Cell Vehicles: Fundamentals, Theory, and Design; CRC Press LLC: Boca Raton, FL, USA, 2005. [Google Scholar]
  4. ElMenshawy, M.; Massoud, A. Modular Isolated DC-DC Converters for Ultra-Fast EV Chargers: A Generalized Modeling and Control Approach. Energies 2020, 13, 2540. [Google Scholar] [CrossRef]
  5. Wang, X.; He, Z.; Yang, J. Electric vehicle fast-charging station unified modeling and stability analysis in the dq frame. Energies 2018, 11, 1195. [Google Scholar] [CrossRef] [Green Version]
  6. Yang, X.; Li, J.; Zhang, B.; Jia, Z.; Tian, Y.; Zeng, H.; Lv, Z. Virtual Synchronous Motor Based-Control of a Three-Phase Electric Vehicle Off-Board Charger for Providing Fast-Charging Service. Appl. Sci. 2018, 8, 856. [Google Scholar]
  7. Lv, Z.; Xia, Y.; Chai, J.; Yu, M.; Wei, W. Distributed Coordination Control Based on State-of-Charge for Bidirectional Power Converters in a Hybrid AC/DC Microgrid. Energies 2018, 11, 1011. [Google Scholar] [CrossRef] [Green Version]
  8. Zhu, Y.; Wang, T.; Xiong, L.; Zhang, G.; Qian, X. Parallel Control Method Based on the Consensus Algorithm for the Non-Isolated AC/DC Charging Module. Energies 2018, 11, 2828. [Google Scholar] [CrossRef] [Green Version]
  9. Hõimoja, H.; Vasiladiotis, M.; Grioni, S.; Capezzali, M.; Rufer, A.; Püttgen, H.B. Toward Ultrafast Charging of Electric Vehicles; 2012 CIGRE Session: Paris, France, 2012. [Google Scholar]
  10. Tu, H.; Feng, H.; Srdic, S.; Lukic, S. Extreme Fast Charging of Electric Vehicles: A Technology Overview. IEEE Trans. Transp. Electrif. 2019, 5, 861–878. [Google Scholar] [CrossRef]
  11. Ronanki, D.; Kelkar, A.; Williamson, S.S. Extreme fast charging technology—Prospects to enhance sustainable electric transportation. Energies 2019, 12, 3721. [Google Scholar] [CrossRef] [Green Version]
  12. Monteiro, V.; Pinto, J.G.; Ferreira, J.C.; Goncalves, H.; Alfonso, J.L. Bidirectional multilevel converter for electric vehicles. In Proceedings of the 2012 Annual Seminar on Automation, Industrial Electronics and Instrumentation, Guimarães, Portugal, 11–13 July 2012; pp. 434–439. [Google Scholar]
  13. Yuan, Z.; Xu, H.; Chao, Y.; Zhang, Z. A novel fast charging system for electrical vehicles based on input-parallel output-parallel and output-series. In Proceedings of the 2017 IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific), Harbin, China, 7–10 August 2017; pp. 1–6. [Google Scholar]
  14. Beldjajev, V. Research and Development of the New Topologies for the Isolation Stage of the Power Electronic Transformer. Master’s Thesis, Allinn University of Technology, Tallinn, Estonia, 2013. [Google Scholar]
  15. Engel, S.P.; Stieneker, M.; Soltau, N.; Rabiee, S.; Stagge, H.; de Doncker, R.W. Comparison of the Modular Multilevel DC Converter and the Dual-Active Bridge Converter for Power Conversion in HVDC and MVDC Grids. IEEE Trans. Power Electron. 2015, 30, 124–137. [Google Scholar] [CrossRef]
  16. Sari, H.I. DC/DC Converters for Multi-Terminal HVDC Systems Based on Modular Multilevel Converter. Master’s Thesis, Norwegian University of Science and Technology, Trondheim, Norway, August 2016. [Google Scholar]
  17. Yang, H. Modular and Scalable DC-DC Converters for Medium-/High-Power Applications. Master’s Thesis, Georgia Institute of Technology, Atlanta, GA, USA, 2017. [Google Scholar]
  18. Fan, H.; Li, H. A high-frequency medium-voltage DC-DC converter for future electric energy delivery and management systems. In Proceedings of the 8th International Conference on Power Electronics—ECCE Asia, Jeju, Korea, 29 May–2 June 2011; pp. 1031–1038. [Google Scholar]
  19. Papadakis, C. Protection of HVDC Grids Using DC Hub. Master Thesis, Delft University of Technology, Delft, The Netherlands, September 2017. [Google Scholar]
  20. Carrizosa, M.J.; Benchaib, A.; Alou, P.; Damm, G. DC transformer for DC/DC connection in HVDC network. In Proceedings of the 2013 15th European Conference on Power Electronics and Applications (EPE), Lille, France, 2–6 September 2013; pp. 1–10. [Google Scholar]
  21. Vasiladiotis, M.; Rufer, A. A Modular Multiport Power Electronic Transformer with Integrated Split Battery Energy Storage for Versatile Ultrafast EV Charging Stations. IEEE Trans. Ind. Electron. 2014, 62, 3213–3222. [Google Scholar] [CrossRef]
  22. Mortezaei, A.; Abdul-Hak, M.; Simoes, M.G. A Bidirectional NPC-based Level 3 EV Charging System with Added Active Filter Functionality in Smart Grid Applications. In Proceedings of the 2018 IEEE Transportation Electrification Conference and Expo (ITEC), Long Beach, CA, USA, 13–15 June 2018; pp. 201–206. [Google Scholar]
  23. Tian, Q.; Huang, A.Q.; Teng, H.; Lu, J.; Bai, K.H.; Brown, A.; McAmmond, M. A novel energy balanced variable frequency control for input-series-output-parallel modular EV fast charging stations. In Proceedings of the 2016 IEEE Energy Conversion Congress and Exposition (ECCE), Milwaukee, WI, USA, 18–22 September 2016; pp. 1–6. [Google Scholar]
  24. De Doncker RW, A.A.; Divan, D.M.; Kheraluwala, M.H. A three-phase soft-switched high-power-density DC/DC converter for high-power applications. IEEE Trans. Ind. Appl. 1991, 27, 63–73. [Google Scholar] [CrossRef]
  25. Zahid, Z.U.; Dalala, Z.M.; Chen, R.; Chen, B.; Lai, J.-S. Design of bidirectional dc-dc resonant converter for vehicle-to-grid (v2g) applications. IEEE Trans. Transp. Electrif. 2015, 1, 232–244. [Google Scholar] [CrossRef]
  26. Cui, T.; Liu, C.; Shan, R.; Wang, Y.; Kong, D.; Guo, J. A Novel Phase-Shift Full-Bridge Converter with Separated Resonant Networks for Electrical Vehicle Fast Chargers. In Proceedings of the 2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC), Shenzhen, China, 4–7 November 2018; pp. 1–6. [Google Scholar]
  27. Srdic, S.; Liang, X.; Zhang, C.; Yu, W.; Lukic, S. A SiC-based high-performance medium-voltage fast charger for plug-in electric vehicles. In Proceedings of the 2016 IEEE Energy Conversion Congress and Exposition (ECCE), Milwaukee, WI, USA, 18–22 September 2016; pp. 1–6. [Google Scholar]
  28. Justino, J.C.G.; Parreiras, T.M.; Filho, B.J.C. Hundreds kW Charging Stations for e-Buses Operating Under Regular Ultra-Fast Charging. IEEE Trans. Ind. Appl. 2016, 52, 1766–1774. [Google Scholar]
  29. Everts, J. Modeling and Optimization of Bidirectional Dual Active Bridge AC–DC Converter Topologies. Ph.D. Thesis, KU Leuven, Leuven, Belgium, March 2014. [Google Scholar]
  30. Marz, M.; Schletz, A.; Eckardt, B.; Egelkraut, S.; Rauh, H. Power Electronics System Integration for Electric and Hybrid Vehicles. In Proceedings of the 6th International Conference on Integrated Power Electronics Systems (CIPS 2010), Nuremberg, Germany, 16–18 March 2010; pp. 1–10. [Google Scholar]
  31. Emadi, A.; Lee, Y.-J.; Rajashekara, K. Power Electronics and Motor Drives in Electric, Hybrid Electric, and Plug-In Hybrid Electric Vehicles. IEEE Trans. Ind. Electron. 2008, 55, 2237–2245. [Google Scholar] [CrossRef]
  32. Schoner, H.P.; Hille, P. Automotive power electronics. New challenges for power electronics. In Proceedings of the IEEE 31st Annual Power Electronics Specialists Conference (PESC 2000), Galway, Ireland, 18–23 June 2000; Volume 1, pp. 6–11. [Google Scholar]
  33. Kolar, J.W.; Drofenik, U.; Biela, J.; Heldwein, M.L.; Ertl, H.; Friedli, T.; Round, S.D. PWM Converter Power Density Barriers. In Proceedings of the Power Conversion Conference (PCC 2007), Nagoya, Japan, 2–5 April 2007; pp. 9–29. [Google Scholar]
  34. Kolar, J.W.; Biela, J.; Waer, S.; Friedli, T.; Badstuebner, U. Performance Trends and Limitations of Power Electronic Systems. In Proceedings of the 6th International Conference on Integrated Power Electronics Systems (CIPS 2010), Nuremberg, Germany, 16–18 March 2010; pp. 1–20. [Google Scholar]
  35. Gu, W.-J.; Liu, R. A Study of Volume and Weight vs. Frequency for High-Frequency Transformers. In Proceedings of the IEEE 24th Annual Power Electronics Specialists Conference (PESC 1990), Seattle, WA, USA, 27–30 September 1993; pp. 1123–1129. [Google Scholar]
  36. Vlatkovic, V.; Sabate, J.A.; Ridley, R.B.; Lee, F.C.; Cho, B.H. Small-signal analysis of the phase-shifted PWM converter. IEEE Trans. Power Electron. 1992, 7, 128–135. [Google Scholar] [CrossRef]
  37. Lian, Y.; Adam, G.; Holliday, D.; Finney, S. Modular input-parallel output-series DC/DC converter control with fault detection and redundancy. IET Gener. Transm. Distrib. 2016, 10, 1361–1369. [Google Scholar] [CrossRef] [Green Version]
  38. Ruan, X.; Chen, W.; Cheng, L.; Tse, C.K.; Yan, H.; Zhang, T. Control Strategy for Input-Series–Output-Parallel Converters. IEEE Trans. Ind. Electron. 2009, 56, 1174–1185. [Google Scholar] [CrossRef]
  39. Lian, Y.; Adam, G.P.; Holliday, D.; Finney, S.J. Medium-voltage DC/DC converter for offshore wind collection grid. IET Renew. Power Gener. 2016, 10, 651–660. [Google Scholar] [CrossRef]
  40. ElMenshawy, M.; Massoud, A. Multimodule ISOP DC-DC Converters for Electric Vehicles Fast Chargers. In Proceedings of the 2019 2nd International Conference on Smart Grid and Renewable Energy (SGRE), Doha, Qatar, 19–21 November 2019; pp. 1–6. [Google Scholar]
  41. ElMenshawy, M.; Massoud, A. Multimodule DC-DC Converters for High-Voltage High-Power Renewable Energy Sources. In Proceedings of the 2019 2nd International Conference on Smart Grid and Renewable Energy (SGRE), Doha, Qatar, 19–21 November 2019; pp. 1–6. [Google Scholar]
  42. Krismer, F.; Kolar, J. Accurate Power Loss Model Derivation of a High-Current Dual Active Bridge Converter for an Automotive Application. IEEE Trans. Ind. Electron. 2010, 57, 881–891. [Google Scholar] [CrossRef]
  43. Marxgut, C.B. Ultra-Flat Isolated Single-Phase AC-DC Converter Systems. Ph.D. Thesis, Swiss Federal Institute of Technology (ETH Zurich), Power Electronic Systems (PES) Laboratory, Zurich, Switzerland, 2013. [Google Scholar]
  44. Marxgut, C.; Krismer, F.; Bortis, D.; Kolar, J.W. Ultrafast Interleaved Triangular Current Mode (TCM) Single-Phase PFC Rectifier. IEEE Trans. Power Electron. 2014, 29, 873–882. [Google Scholar] [CrossRef]
  45. Krismer, F.; Kolar, J.W. Closed Form Solution for Minimum Conduction Loss Modulation of DAB Converters. IEEE Trans. Power Electron. 2012, 27, 174–188. [Google Scholar] [CrossRef]
  46. Barrera-Cardenas, R.; Molinas, M. A Simple Procedure to Evaluate the Efficiency and Power Density of Power Conversion Topologies for Offshore Wind Turbines. Energy Procedia 2012, 24, 202–211. [Google Scholar] [CrossRef] [Green Version]
  47. Pavlovsky, M.; de Haan, S.W.H.; Ferreira, J.A. Reaching High Power Density in Multikilowatt DC-DC Converters with Galvanic Isolation. IEEE Trans. Power Electron. 2009, 24, 603–612. [Google Scholar] [CrossRef]
  48. Whitaker, B.; Barkley, A.; Cole, Z.; Passmore, B.; Martin, D.; McNutt, T.R.; Lostetter, A.B.; Lee, J.S.; Shiozaki, K. A High-Density, High-Efficiency, Isolated On-Board Vehicle Battery Charger Utilizing Silicon Carbide Power Devices. IEEE Trans. Power Electron. 2014, 29, 2606–2617. [Google Scholar] [CrossRef]
  49. Sha, D.; Guo, Z.; Liao, X. Cross-Feedback Output-Current-Sharing Control for Input-Series-Output-Parallel Modular DC-DC Converters. IEEE Trans. Power Electron. 2010, 25, 2762–2771. [Google Scholar] [CrossRef]
Figure 1. DAB converter circuit diagram.
Figure 1. DAB converter circuit diagram.
Energies 13 04949 g001
Figure 2. Block diagram for a typical EV UFC.
Figure 2. Block diagram for a typical EV UFC.
Energies 13 04949 g002
Figure 3. Generalized hybrid multimodule DC-DC converter configuration.
Figure 3. Generalized hybrid multimodule DC-DC converter configuration.
Energies 13 04949 g003
Figure 4. Small signal model for the generalized hybrid ISIP-OSOP multimodule DC-DC converter.
Figure 4. Small signal model for the generalized hybrid ISIP-OSOP multimodule DC-DC converter.
Energies 13 04949 g004
Figure 5. Eight-module ISOP multimodule DC-DC converter circuit diagram; (a) Conventional ISOP DC-DC Converter, (b) Hybrid ISOP DC-DC Converter, (c) DAB Converter based on IGBTs, (d) DAB Converter based on MOSFETs.
Figure 5. Eight-module ISOP multimodule DC-DC converter circuit diagram; (a) Conventional ISOP DC-DC Converter, (b) Hybrid ISOP DC-DC Converter, (c) DAB Converter based on IGBTs, (d) DAB Converter based on MOSFETs.
Energies 13 04949 g005
Figure 6. Hybrid ISOP DC-DC converter small-signal model for eight-modules.
Figure 6. Hybrid ISOP DC-DC converter small-signal model for eight-modules.
Energies 13 04949 g006
Figure 7. Hybrid Efficiency loss curve with respect to power loading.
Figure 7. Hybrid Efficiency loss curve with respect to power loading.
Energies 13 04949 g007
Figure 8. Converter components volume contribution in liters considering hard switching operation.
Figure 8. Converter components volume contribution in liters considering hard switching operation.
Energies 13 04949 g008
Figure 9. Converter components volume contribution in liters considering soft-switching operation.
Figure 9. Converter components volume contribution in liters considering soft-switching operation.
Energies 13 04949 g009
Figure 10. OCS control scheme for the proposed hybrid ISOP DC-DC converter.
Figure 10. OCS control scheme for the proposed hybrid ISOP DC-DC converter.
Energies 13 04949 g010
Figure 11. Simulation results for the eight-module hybrid ISOP system.
Figure 11. Simulation results for the eight-module hybrid ISOP system.
Energies 13 04949 g011
Table 1. Individual module system parameters representation in terms of the overall system ratings.
Table 1. Individual module system parameters representation in terms of the overall system ratings.
ParametersRepresentationValue
Primary group
Input current α L 2   I i n α L 1 α L 2 = K L if the two groups are connected in parallel at the input side, otherwise α L 2 = 1
Input voltage β L 2   V i n β L 1 β L 2   = K L if the two groups are connected in series at the input side, otherwise β L 2   = 1
Output current a L 2 I o a L 1 a L 2 = K L if the two groups are connected in parallel at the output side, otherwise a L 2 = 1
Output voltage b L 2 V o b L 1 b L 2 = K L if the two groups are connected in series at the output side, otherwise b L 2 = 1
Secondary group
Input current α M 2   I i n α M 1 α M 2 = K M if the two groups are connected in parallel at the input side, otherwise α M 2 = 1
Input voltage β M 2   V i n β M 1 β M 2   = K M if the two groups are connected in series at the input side, otherwise β M 2   = 1
Output current a M 2 I o L a M 1 a M 2 = K M if the two groups are connected in parallel at the output side, otherwise a M 2 = 1
Output voltage b M 2 V o b M 1 b M 2 = K M if the two groups are connected in series at the output side, otherwise b M 2 = 1
Table 2. Generalized model verification with the eight-module hybrid ISOP DC-DC converter.
Table 2. Generalized model verification with the eight-module hybrid ISOP DC-DC converter.
Transfer Functions for an Eight-Module Hybrid ISOP DC-DC Converter
G v d L V i n 5 K 1 s 2 L L C L + s ( L L R + R d L C L ) + R d L R + 4
G v d M V i n 20 K 2 s 2 L M C M + s ( b M 1 L M R + R d M C M ) + R d M R + 4
G i d L V i n 5 K 1 ( s R C L + 1 ) R ( s 2 L L C L + s ( L L R + R d L C L ) + R d L R + 4 )
G i d M V i n 20 K 2 ( s R C M + b M 1 ) R ( s 2 L M C M + s ( L M R + R d M C M ) + R d M R + 4 )
Z o u t L ( R d L + s L L ) s 2 L L C L + s ( L L R + R d L C L ) + R d L R + 4
Z o u t M ( R d M + s L M ) s 2 L M C M + s ( L M R + R d M C M ) + R d M R + 4
G v g L D e f f 1 K 1 ( 1 + R d L 5 R ) s 2 L L C L + s ( L L R + R d L C L ) + R d L R + 4
G v g M D e f f 2 K 2 ( 1 + R d M 20 R ) s 2 L M C M + s ( L M R + R d M C M ) + R d M R + 4
Table 3. System parameters for conventional and hybrid multimodule DC-DC converters.
Table 3. System parameters for conventional and hybrid multimodule DC-DC converters.
ParametersMultimodule Converter Relying on the Secondary GroupMultimodule Converter Relying on the Primary GroupHybrid Multimodule Converter
Primary GroupSecondary Group
Total rated power 200   kW 160   kW 40   kW
Rated power per module 10   kW 40   kW 40   kW 10   kW
Overall input voltage 10   kV 8   kV 2   kV
Input voltage per module 500   V 2   kV 2   kV 500   V
Total input current 20   A
Input current per module 20   A
Overall output voltage 400   V
Output voltage per module 400   V
Total output current 500   A 400   A 100   A
Output current per module 25   A 100   A 100   A 25   A
Number of modules 20 5 Total of 8
4 4
Switching frequency 100   kHz 10   kHz 100   kHz 10   kHz
Table 4. System parameters used in simulation.
Table 4. System parameters used in simulation.
ParametersPrimary Multimodule GroupSecondary Multimodule Group
Module 1Module 2Module 3Module 4Module 1Module 2Module 3Module 4
Overall converter rated power 200   kW
160   kW 40   kW
Rated power per module 40   kW 10   kW
Total input voltage 10   kV
8   kV 2   kV
Input voltage per module 2   kV 500   V
Overall output voltage 400   V
Module output voltage 400   V
DAB units 8
Turns ratio 1 : 1 1 : 0.95 1 : 0.9 1 : 0.85 4 : 1 4 : 0.95 4 : 0.9 4 : 0.85
Leakage inductance 80   μ H 89   μ H 99   μ H 11   μ H 500   nH 554   nH 617   nH 692   nH
Effective duty cycle 0.8 0.84 0.89 0.94 0.8 0.84 0.89 0.94
Input capacitance 50   μ F 80   μ F 50   μ F 80   μ F 35   μ F 57   μ F 35   μ F 57   μ F
Filter inductance 50   mH 60   mH 60   mH 50   mH 35   mH 42   mH 42   mH 35   mH
Filter capacitance 300   μ F
Resistance 0.8   Ω
Switching frequency 10   kHz 100   kHz

Share and Cite

MDPI and ACS Style

ElMenshawy, M.; Massoud, A. Hybrid Multimodule DC-DC Converters for Ultrafast Electric Vehicle Chargers. Energies 2020, 13, 4949. https://doi.org/10.3390/en13184949

AMA Style

ElMenshawy M, Massoud A. Hybrid Multimodule DC-DC Converters for Ultrafast Electric Vehicle Chargers. Energies. 2020; 13(18):4949. https://doi.org/10.3390/en13184949

Chicago/Turabian Style

ElMenshawy, Mena, and Ahmed Massoud. 2020. "Hybrid Multimodule DC-DC Converters for Ultrafast Electric Vehicle Chargers" Energies 13, no. 18: 4949. https://doi.org/10.3390/en13184949

APA Style

ElMenshawy, M., & Massoud, A. (2020). Hybrid Multimodule DC-DC Converters for Ultrafast Electric Vehicle Chargers. Energies, 13(18), 4949. https://doi.org/10.3390/en13184949

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop