Article

Experimental Study on the Catalytic Ignition Characteristics of a Dual-Mode Ionic Liquid Propellant in Model Thrusters

1
Beijing Institute of Control Engineering, Beijing 100190, China
2
Beijing Engineering Research Center of Efficient and Green Aerospace Propulsion Technology, Beijing 100190, China
3
Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
*
Author to whom correspondence should be addressed.
Energies 2022, 15(22), 8730; https://doi.org/10.3390/en15228730
Submission received: 26 October 2022 / Revised: 14 November 2022 / Accepted: 15 November 2022 / Published: 20 November 2022
(This article belongs to the Special Issue Recent Advances and Challenges in Space Propulsion Technology)

Abstract

:
An experimental study was carried out on the ignition characteristics of the HAN/(Emim)(EtSO4) (hydroxylammonium nitrate and 1-ethyl-3-methyl-imidazolium ethyl sulfate) dual-mode ionic liquid monopropellant in chemical propulsion mode in model thrusters. Firstly, a model thruster with a detachable convergent nozzle was designed and fabricated. Secondly, catalytic ignition experiments at different flow rates were carried out in atmosphere and in high chamber pressure environment, respectively, using a model thruster, with and without the convergent nozzle. During the catalytic ignition process, measurement methods such as thermocouple, pressure sensor, and flue gas analyzer were employed to obtain the temperature at different depths of the catalytic bed, the pressure of the combustion chamber, and the concentration variations of gaseous products CO, CO2, CH4, SO2, NO, and NO2. Then the three characteristic stages of water evaporation, HAN decomposition, and (Emim)(EtSO4) combustion were analyzed at the initiation time, and the reaction characteristics in the process of the catalytic ignition were analyzed. In addition, the composition and concentration of the combustion products at equilibrium were theoretically calculated. The effects of temperature and pressure on the concentrations of five main gaseous products were studied. Finally, the exhaust gas of the three groups of catalytic ignition experiments under different pressure environments was separately collected and measured with gas chromatography (GC) when the experiments approached equilibrium, the result of which roughly agrees with the theoretical calculations. These results are of great significance for exploring the chemical propulsion of the dual-mode ionic liquid propellant and understanding its physical catalytic combustion mechanisms.

1. Introduction

Multimode space propulsion refers to the integration of two or more propulsion modes into a single propulsion system using shared propellant [1], such as the combination of monopropellant and bipropellant chemical rocket engines [2], the combination of monopropellant and electrospray propulsion, and Hall-effect (HET) system [3] which operates at either high-thrust mode or high-specific impulse mode, etc. Among them, the dual-mode space propulsion technology based on the novel ionic liquid monopropellant has received wide attention. This technology adopts the monopropellant chemical propulsion mode to realize a large thrust and attains the high specific impulse through the electrospray propulsion mode. Thus, it will provide unprecedented flexibility and adaptability to spacecraft. Moreover, the comprehensive efficiency of the shared propellant will be significantly improved and a mass saving of the propulsion system for space missions can be acquired [4,5].
As for the novel ionic liquid monopropellant, ionic liquid (IL) is a kind of molten salt, and the cations and anions are in a dissociated state. IL has some unique properties such as liquidity over a wide temperature range, high thermal stability, structural designability, the ability to dissolve a wide range of chemical species, low vapor pressure, and ionic conductivity, etc. [6]. In 2010, Brian R. Donius [7] from Missouri University of Science and Technology presented an analytical and numerical investigation into the performance of a dual-mode propulsion system using ionic liquids, with high-thrust chemical propulsion and high-specific impulse electric propulsion, pointing out that a similar performance to traditional storable propellant combinations was possible if ionic liquids were combined with a hydroxylammonium nitrate (HAN) oxidizer. It was also suitable as an electrospray propulsion because of its negligible vapor pressure [8].
Following that, Steven P. Berg and Joshua L. Rovey conducted a continuing study. Chemical-electrospray dual-mode propulsion technology requires a liquid propellant with physical properties of high density, low melting point, low viscosity, high surface tension, high electrical conductivity, and high molecular weight. Based on the performance requirements of the electrospray propellant, the final choice was imidazole-based ionic liquids [9]. After studying (Bmim)(dca), (Bmim)(NO3), and 1-ethyl-3-methyl-imidazolium ethyl sulfate (Emim)(EtSO4), it was found that their physicochemical properties are no less than that of hydrazine [10] and the currently widely used (Emim)(Im) electrospray propellant. These ionic liquids had the potential to form dual-mode ionic liquid propellants when they were mixed with oxidizing salts, such as HAN, as fuels [11]. Therefore, they synthesized monopropellants in which HAN was mixed with (Bmim)(NO3), (Emim)(EtSO4) respectively [12], and carried out experimental studies in both electrospray and chemical propulsion. On the one hand, electrospray experiments at different flow rates in a 100 μm capillary emitter were conducted [13], on the other hand, the catalytic decomposition characteristics of the HAN/(Emim)(EtSO4) propellant was tested on the surface of platinum, rhenium, and titanium [14], and the linear combustion rate of propellants under different pressures was measured and evaluated in a pressurized fixed volume reactor [15]. Then, a microtubule model was established to integrate the dual-mode thruster hardware device. After that, a platinum microtubule with an inner diameter of 0.4 mm was designed, in which decomposition experiments of the HAN/(Emim)(EtSO4) propellant were carried out [16].
In 2020, based on Berg and Rovey’s research, Froberg Aerospace [17] demonstrated a Monoprop-Electrospray Propulsion System (MEPS) using the shared multimode propellant FAM-110A (59% wt. HAN, 41% wt. (Emim)(EtSO4), <1% H2O). MEPS microthruster consists of a stainless-steel block containing a 16 by 16 emitter array. Each emitter was lined with a catalyst layer, and each had a sharpened emitter tip at the emitter exit. It can be used as a chemical monopropellant thruster and a capillary electrospray thruster and can switch between them. Two operating modes of the MEPS were tested with stable combustion times of up to 45 s in the chemical propulsion mode [17] and more than 4 h in the electrospray mode [18]. In addition, Wang [19] also prepared a series of imidazole-based ionic liquids and mixed them with the HAN to form novel ionic liquid propellants. Their physical and chemical properties were studied, and a drop test was carried out proving that the HAN/(Emim)(EtSO4) blend propellant had good catalytic decomposition and combustion performance. It was a new multimode ionic liquid propellant with a potential application.
Previous research has carried relatively systematic work on the screening, synthesis, and physicochemical properties of dual-mode ionic liquid propellants. The feasibility of electrospray mode and chemical propulsion mode has also been explored. A dual-mode propulsion prototype has been developed and a preliminary test has been carried out. However, the propellant’s working characteristics under both modes need more study. For the chemical propulsion mode, plenty of research needs to be done to figure out the catalytic combustion characteristics of the propellant, and get an in-depth understanding of the chemical reaction process of the propellant under continuous flow in the space thruster.
Recently, Gao [20] studied the thermal and catalytic decomposition of the new ionic liquid propellant with thermogravimetric experimental analysis (TGA-DSC) and analyzed the exhaust gas using Fourier transform infrared spectroscopy measurement (FTIR). A chemical microthruster [21] was designed by the University of Illinois Urbana-Champaign, Froberg Aerospace, and the University of Southampton and then tested using FAM-110A propellant. Li [22] built a set of catalytic ignition devices, successfully ignited a dual-mode ionic liquid propellant in the atmosphere and studied its catalytic ignition characteristics. Tang [23] designed a novel ignition actuator using the plasma-assisted microwave torch to ignite an ionic liquid monopropellant. Fang [24] conducted catalytic ignition experiments of the same propellant under a vacuum environment to explore the combustion characteristics of the propellant at a flow rate of 1 mL/min~4 mL/min.
Based on the previous work [19,22,24], this research seeks to approach closer to the actual working conditions of the space thruster under chemical propulsion mode. We designed a model thruster with a detachable convergent nozzle, built an atmospheric experimental stand, and then carried out catalytic ignition experiments of a dual-mode ionic liquid propellant at different flow rates. At the same time, variations in temperature, pressure, gaseous products, and their respective concentration in the catalytic ignition progress were measured. The theoretical calculation of the combustion products at equilibrium was performed using the NASA Chemical Equilibrium with Application (CEA) code. For comparison, gas chromatography (GC) analyzed the collected gas when the reaction approached equilibrium.

2. Methodology

2.1. Model Thruster and Experimental Setup

Figure 1a displays a model thruster and the experimental stand used in the experiment. The HAN/(Emim)(EtSO4) dual-mode ionic liquid monopropellant (a blend of (Emim)(EtSO4), HAN and water) flows in from the upstream inlet, and the solenoid valve controls if the propellant can flow into the model thruster. Then the propellant is injected into the catalytic bed through the injector. The catalytic bed is filled with black Ir/Al2O3 catalysts. Differing from hypergolic ionic liquids [25,26], the HAN/(Emim)(EtSO4) propellant needs to be preheated, so the outside surface of the catalytic bed is wound by a heating wire. When the propellant contacts the preheated catalyst, the catalyst decomposes. Then the generated gas will be discharged through the downstream outlet.
Figure 1b shows an atmospheric experimental stand, placed in the atmospheric environment. The main structure includes a pedestal at the bottom, four support rods, and a flange plate on the top. The pedestal and support rods play the roles of fixing and supporting. The flange plate is placed on the support rods, and the limiters on the rods can adjust the height of the flange plate. In the center of the flange plate is welded a connecting pipe. One end below the pipe is connected with the model thruster, and the other end is connected with the propellant injection pump controlling the flow rate of the liquid propellant. Around the pipe, there are multiple terminals, through which the wirings of the thruster are uniformly connected to other equipment. At the downstream outlet of the thruster, a flue gas analyzer (Vario plus) is placed to directly measure the main gas components and their corresponding concentrations of the catalytic combustion reaction, or a gas sampling bag is placed to collect the gaseous products for later testing by gas chromatography (GC) analysis.
It should be pointed out that the flue gas analyzer has limitations on the measurement range of the corresponding components. The specific numerical range is shown in Table 1. As presented from the calibration results, the instrument had good accuracy in the measurement range. When the concentration of a gas component exceeded its measurement range, the deviation of the results increased, and the reliability of the numerical results decreased, then only the variation trend can be analyzed.
The catalytic bed and the detachable convergent nozzle downstream of the model thruster are connected by a thread. As shown in Figure 2a, the inner diameter of the catalytic bed is 10 mm, the length is 44 mm, and there are five thermocouple sockets on one side. To measure the temperature change at different positions in the catalytic bed, five K-type thermocouples respectively recorded as TC0, TC1, TC2, TC3, and TC4 from upstream to downstream, are inserted into the centerline of the catalytic bed through the sockets. Among these thermocouples, TC0 is just at the junction where the injector connects with the catalytic bed, and the propellant will first come into contact with TC0 after entering the catalytic bed.
As shown in Figure 2b,c, inside the convergent nozzle is a combustion chamber with a diameter of 10 mm and a height of 10 mm. The diameter of the downstream throat is 0.4 mm so that the combustion chamber can be pressurized to form a high chamber pressure environment. A thin tube is welded to the outer wall of the combustion chamber, which connects to a pressure sensor (XTEH-10L-190M-14BARA-4) to acquire the pressure data inside.
The data measured by the thermocouples and the pressure sensor are recorded at 10 Hz and transmitted to the computer for display and storage. The catalytic bed will be in an atmospheric environment if the convergent nozzle is removed. Moreover, the high combustion chamber pressure environment can be realized by connecting with the convergent nozzle, as a result of which catalytic ignition experiments under different pressure environments can be accomplished by running the model thruster with or without a convergent nozzle.
Figure 3 demonstrates the preheating temperature distribution at different depths of the catalytic bed. It can be seen from the figure that the temperature in the middle stream is higher, while the temperature in the upstream and downstream is slightly lower. Except for TC4, the standard deviation of each position is about 1 °C, so the preheating operation has good repeatability.

2.2. Experimental Procedure

The procedure of operating a model thruster without the convergent nozzle to conduct a catalytic ignition experiment in an atmospheric environment is as follows. Firstly, the catalytic bed is preheated with a heating wire, and N2 is introduced to blow out the residual air in the catalytic bed. When the temperature of the TC0 stabilizes at 200 °C, open the solenoid valve, start the propellant injection pump to inject the dual-mode ionic liquid propellant into the model thruster at a fixed flow rate, and perform catalytic ignition in the catalytic bed. Secondly, observe the experimental phenomena and record the temperature change measured by the thermocouples at different depths. Meanwhile, a flue gas analyzer is placed at the downstream outlet to measure the gaseous products during ignition. Remove the flue gas analyzer after the combustion reaches equilibrium, turn to a gas sampling bag to collect the gas discharged from the outlet, and test with GC analysis later. Then stop the propellant feed, and blow air in so that the residual propellant in the pipeline and the incompletely reacted components in the catalytic bed can completely burn and be purged. Finishing the current operation and the next experiment can be repeated after the temperature drops. The model thruster can be preheated again and obey the same steps running the catalytic ignition experiment at the flow rate of 1~4 mL/min in sequence.
The process of using a model thruster with the convergent nozzle to carry out catalytic ignition experiments is similar to the above, but there is an additional measurement of the combustion chamber pressure in the combustion chamber. The required thrust of the propellant injection pump will increase with the build-up of the high chamber pressure, while the maximum thrust of the injection pump is limited. Therefore, only catalytic ignition experiments of 1–3 mL/min are carried out.

3. Catalytic Ignition Experiment of a Model Thruster without the Convergent Nozzle

Catalytic ignition experiments under flow rates of 1~4 mL/min were carried out in a model thruster without the convergent nozzle on the atmospheric experimental stand. Temperatures at different depths of the catalytic bed and the concentrations of several main gaseous products in the ignition progress were measured.

3.1. Variation of Catalytic Bed Temperatures

It can be seen from Figure 4a,b that under the condition of small flow rates, the temperature at TC0 rose before other downstream positions after the propellant entered the catalytic bed and contacted the preheated catalyst. Soon after the propellant reached TC0 it began to decompose to release heat. Later the TC0 temperature curve showed swift rises in two stages. The first stage rose from the initial temperature of 200 °C to around 300 °C, and then the increasing rate slowed down. The second stage rapidly rose to above 600 °C, and then gradually approached stability. Since the decomposition process of the HAN/(Emim)(EtSO4) monopropellant exists in multiple steps [19,22], it can be inferred that the first rising stage of TC0 was due to the decomposition of the oxidant component HAN, and the second stage resulted from the decomposition of the fuel component (Emim)(EtSO4). Moreover, the fuel component released more heat, contributing to a greater increase in the temperature curve in the second stage.
Figure 4c illustrates that at a flow rate of 3 mL/min, following the first rising stage, there was no rapid increase of the second rising stage of TC0, but it was maintained at around 300 °C. While it was TC1 that completed the second rapid ascent because the greater flow rate made the propellant flow downstream to TC1 during HAN decomposition, so (Emim)(EtSO4) decomposed at TC1 to release a large amount of heat so that the highest temperature of TC1 exceeded 1000 °C. At about 130 s, TC1 temperature decreased slightly, and TC0 rose swiftly, did the main combustion exothermic region of the propellant beginning to move upstream.
Continuing to increase the flow rate. Figure 4d demonstrates that at a flow rate of 4 mL/min, TC0 rose rapidly in the first stage but then fell, following which TC1 ascended quickly. This was because the propellant at room temperature entered the catalytic bed with a larger flow rate and absorbed the heat at TC0 for convection. Then the fuel component accessed TC1 to decompose and released so much heat that it contributed to the second rising stage so that TC1 temperature went up swiftly to around 1200 °C. At about 260 s, TC1 to TC4 all decreased in temperature to varying degrees. However, the TC0 temperature ascended rapidly and ultimately stabilized at around 900 °C, which revealed that the main combustion exothermic region of the propellant had moved to TC0.
As mentioned above, two rising stages of the temperature curves of the catalytic bed of a model thruster without the convergent nozzle at the flow rate of 1~4 mL/min were analyzed. The characters of each stage and the maximum temperature under a separate flow rate are summarized and listed in Table 2.

3.2. Analysis of Gaseous Products of the Catalytic Ignition Process in a Model Thruster without the Convergent Nozzle

During the catalytic ignition experiment of the model thruster without the convergent nozzle in the atmospheric pressure environment, the inlet pipe of the flue gas analyzer was located at the gas outlet downstream of the catalytic bed. It identified seven gases, O2, CO, CO2, CH4, SO2, NO, and NO2 with the analysis response frequency of 1 Hz, and the measurement results are displayed in Figure 5. The left ordinate which shows the percentage of the gases with relatively high contents of O2, CO, CO2, and CH4 is magnified ten times for better observation, while the ordinate on the right is the ppm of SO2, NO, and NO2 has fewer contents. Since the inlet pipe was placed in the atmospheric environment, the initial oxygen content was close to 21%, and the other gases were almost zero.
Similar to the catalytic ignition process in a vacuum environment [24], in the initial ignition stage, the HAN of the propellant first decomposed, producing a large amount of oxidizing gas NOx, in which the concentration of NO increased before NO2 and its peak value went higher. Next, the C element of the (Emim)(EtSO4) was oxidized into CO2, resulting in a significant ascent in the production of CO2. At the same time, NOx was consumed, so the amount of NO quickly decreased to zero. However, after the NO2 concentration reached a maximum value, it maintained for a while, and then faded away. With the consumption of oxidizing gas content, the incomplete combustion products of fuel components CH4 and CO also started to appear one by one, and then the S element, with less content, was also oxidized to SO2. In the process of the catalytic combustion reaction tending to equilibrium, NO and SO2 successively disappeared, but there was still a trace amount of NO2, while the amount of CO and CO2 remained relatively stable. Observing the change curves of CH4, it can be seen that it fluctuated for a long time under a low flow rate. When approaching the reaction equilibrium, its concentration tended to be smaller as the flow rate increased.

4. Catalytic Ignition Experiment of a Model Thruster with the Convergent Nozzle

Catalytic ignition experiments under flow rates of 1~3 mL/min were conducted in a model thruster with the convergent nozzle in a high chamber pressure environment. Temperatures at different depths of the catalytic bed, the pressure of the combustion chamber, composition, and the concentrations of several main gaseous products in the ignition progress were measured.

4.1. Variation of Catalytic Bed Temperature and Combustion Chamber Pressure

Observing the enlarged part circled in Figure 6, Figure 7 and Figure 8, it displays a small pressure peak arose at the initial stage after the propellant entered the catalytic bed. At the same time, the initial temperature of TC0 decreased slightly. Using the thermogravimetric experiments of Gao [19] and Li [22], this pattern can be judged as due to the evaporation of the water component of the monopropellant, which absorbed heat and turned into water vapor, thereby increasing the pressure.
The temperature at TC0 rose rapidly, before the other downstream positions, while the temperature at TC1 to TC4 gradually increased. Moreover, the further away from the upstream, the slower the temperature increased. This was the result of the propellant beginning to decompose and release plenty of heat soon after contacting the catalyst, leading to a quick ascent of the temperature at TC0. Moreover, the temperature at TC0 was much higher than the temperature downstream. In other words, TC0 was the main regime where the catalytic combustion took place, while the downstream positions heated up primarily relying on the upstream heat transfer. There are also two obvious rising stages of the TC0 curve, identical to the analysis above, which respectively correspond to the decomposition of the HAN and the (Emim)(EtSO4). The difference was that the two rising stages arose only at TC0. The characters of each stage and the maximum temperature under the flow rate of 1~3 mL/min are listed in Table 3. The time for the end of the second rising stage was about 70 s, 55 s, and 45 s. The conclusion can be drawn that the heating rate will also accelerate with the flow rate growth.
In Figure 6, the growth rate of temperatures and pressure slowed down after about 70 s under the flow rate of 1 mL/min. The temperature of TC0 gradually rose and tended to be around 900 °C, and the pressure finally fluctuated around 1.15 bar, which was higher than the atmospheric pressure of 1.01 bar. When the propellant feeding was stopped at about 450 s, the pressure dropped linearly immediately, while the temperature drop was slightly delayed and the drop speed was relatively gentle.
In Figure 7, under the flow rate of 2 mL/min, after about 55 s, the growth rate of temperatures and pressure also slowed down, the temperature of TC0 tending to be close to 1100 °C, while the pressure continued to increase gently. At about 200 s, a gas sampling bag was added surrounding the outlet of the convergent nozzle to collect gaseous products, so that the pressure at the outlet was slowly higher than the atmospheric pressure, leading to the combustion chamber pressure fluctuating in a wider range. At 260 s, it suddenly rose from about 1.5 bar to more than 2.5 bar but then dropped to around 1.5 bar. During this period, TC1–TC4 all had a certain range of temperature rises. After a large range of fluctuation lasting about 5 s, the injection pump was blocked due to its inability to keep a certain thrust, ceasing the feed of propellant. Following that, there appeared to be two stages of cooling and depressurization. The pressure in the first stage dropped to 1.1 bar, rebounded to 1.4 bar, then decreased linearly to 1.2 bar. During this period, TC1–TC3 also set about to decrease. TC4 was far away from the upstream position of the propellant ignition, causing the slightest change. However, there emerged an increase in temperature for TC0 due to a hot reflux. This stage lasted about 40 s. At about 310 s in the second stage, the pressure plummeted to near atmospheric pressure and held steady. In this process, TC0–TC4 temperatures all accelerated their rate of decline.
Under the flow rate of 3 mL/min in Figure 8, after about 45 s, the temperature rise slowed down, and the temperature of TC0 tended to 1000 °C, but the growth rate of the pressure did not decline significantly. When the pressure reached 1.7bar, its fluctuation range enlarged. Soon after that, the propellant injection pump was blocked at about 100 s, and the propellant feeding ended. Then there existed two stages of cooling and depressurization similar to that in Figure 7. In the first stage, the pressure was reduced to around 1.2 bar. In the meantime, TC1–TC3 pressures also started to decrease, although TC4 pressure still rose inertially, while TC0 showed a certain rise due to hot reflux, which it held for about 40 s. In the second stage, from about 140 s, the pressure dropped immediately to close to atmospheric pressure and then remained constant. At the same time, TC0–TC4 pressures also accelerated their rate of decrease.

4.2. Analysis of Gaseous Products of the Catalytic Ignition Process in a Model Thruster with the Convergent Nozzle

During the catalytic ignition experiment of a model thruster with the convergent nozzle, the inlet pipe of the flue gas analyzer was located at the outlet of the convergent nozzle. The rate of the catalytic ignition can also be revealed through the change in the oxygen content. Figure 9a shows that at a flow rate of 1 mL/min, the oxygen concentration decreased gently and was always higher than zero, indicating the catalytic combustion reaction was slow at this time. The low gas production rate prevented the air around the location of the flue gas analyzer inlet pipe from being quickly purged. While in Figure 9b, it shows that at 2 mL/min and 9c 3 mL/min flow rates, the oxygen was close to disappearing at about 60 s and 50 s, respectively. These demonstrates that at the flow rate of 1~3 mL/min, with the increase of flow rate, the catalytic ignition reaction rate also be sped up.
Similar to the catalytic ignition process of a thruster without the convergent nozzle, NO vanished in no time after peaking, while the NO2 concentration was maintained for a time after reaching the maximum value and then gradually decreased but was not entirely consumed. Compare the maximum concentrations of NO and NO2 in Figure 9a–c. It can be seen that increasing the flow rate reduced the NO content produced by the initial HAN decomposition, while the NO2 content increased slightly.

5. Analysis of Gaseous Products at Equilibrium

On the one hand, the gaseous products of the catalytic combustion at equilibrium were theoretically calculated with CEA under different temperatures and different pressure. On the other hand, the exhaust gases of three groups of catalytic ignition experiments under different pressure environments were collected and measured by GC when the experiments were close to equilibrium.

5.1. Theoretical Calculation of CEA

Firstly, we used the NASA Chemical Equilibrium with Application (CEA) [27] computer code (the code for theoretical performance estimation of rocket and satellite propellants) to calculate the concentration changes of several main components of the dual-mode ionic liquid propellant at different pressures (with the temperature of 1400 K) and different temperatures (with the pressure of 1 atm), so that we could theoretically assess the contribution of pressure and temperature to reaction products. To compare with the gas chromatography (GC) analysis results of the following, CO, CO2, CH4, N2, and H2 the CEA calculation results were selected, and the concentrations of these five gases were normalized. The normalized results are presented in Figure 10.
As can be seen in Figure 10a, at the temperature of 1400 K, the pressure had little influence on the content of these five gases at reaction equilibrium. CH4 content was almost zero, H2 content was the highest with a concentration close to 40%, CO content was higher than CO2, with a sum of these two concentrations at about 40%, and the concentration of N2 was slightly higher than 20%.
From Figure 10b, it can be seen that with a pressure of 1 atm, N2, CH4, and CO2 occupied the vast majority of the contents under low temperatures, while the contents of H2 and CO were low or even zero. Within the range of 600~900 K, the concentrations of N2, CH4, and CO2 decreased, while that of H2 and CO increased. When the temperature was greater than 900 K, CH4 gradually disappeared. The variation tendency of N2 and H2 slowed down, while CO continued to increase and CO2 continued to decrease. On the one hand, the high content of H2 indicated an overall reducing atmosphere, so the C element was not completely burned to produce CO. On the other hand, part of CO2 is reduced to CO under a high-temperature environment.
The calculated values and normalized values at different temperatures are given in Table 4. The normalized value of CO, CO2, CH4, N2, and H2 was obtained by dividing the respective calculated value by the total value. Besides the selected five kinds of gases, water vapor also took up a significant proportion. The water vapor concentration was even close to half at low temperatures while the total value occupied a small amount. That’s because the evaporation of water had mainly occurred, and the decomposition reaction rate of oxidant and fuel components was slow in the case of low temperature.

5.2. GC Analysis of the Exhaust Gas

Based on the CEA theoretical calculation, the exhaust gases of the catalytic ignition under the vacuum environment, the atmosphere, and a high chamber pressure environment were separately collected with gas sampling bags when the maximum temperature measured stabilized. The GC analysis of these gases is presented in Figure 11. The maximum temperature was chosen because it was where the reaction mainly occurred. Among the three groups of experiments, the catalytic ignition experiment in the vacuum environment has been reported in the literature [24], and the temperature curves are displayed in Figure 11.
The experiment in the atmosphere was conducted in the model thruster without the convergent nozzle, and the experiment in the high chamber pressure environment was conducted in the model thruster with the convergent nozzle as described in Figure 4c and Figure 8 above. All of them were carried out at a preheating temperature of 200 °C and a feeding flow rate of 3 mL/min. It should be noticed that even though the catalytic ignition experiments approached equilibrium, the pressure and the temperature still fluctuated to a certain extent. Moreover, there existed differences in the temperature at different depths of the catalytic bed. Since the water vapor condensed into liquid water in gas sampling bags, we measured the main components including CO, CO2, CH4, N2, and H2, without water vapor, and the results were normalized.
As was shown in Figure 12, N2 and H2 occupies about 70%, and the three pressure environments had little effect on their concentration, which conformed to the analysis from Figure 10a, but the concentration of carbonaceous matter appeared with some differences. The content ratio of CO2 and CO, i.e., c(CO2/CO), was the lowest at 0.92 in the vacuum environment and the highest at 1.56 in the high chamber pressure environment. In addition, the GC results showed that no CH4 was detected in the vacuum environment, while a small amount of CH4 was produced in the atmosphere and took up a larger proportion in the high chamber pressure environment.

5.3. Comparison of Theoretical Calculation and Experimental Results

Figure 13 demonstrates a comparison of the theoretical calculation and the experimental results. Because the whole temperature of the catalytic bed when approaching equilibrium in a vacuum environment in Figure 11 was the highest, while that in a high chamber pressure environment in Figure 8 was the lowest and its ignition time was the shortest leading to the other temperatures downstream being still on the rise even though the maximum temperature was close to stability. Combining these above features of the analytical and measured results, it can be judged that the three groups of experimental results roughly coincide with the position of 1100 K, 1000 K, and 900 K respectively of the CEA calculation in Figure 10b. As shown in Figure 13, the concentrations of H2 and CH4 measured with GC agreed well with that of the theoretical calculation. Though the experimental value of N2 was higher than the theoretical value, and the experimental values of CO and CO2 were lower, their trends were consistent with that of the theoretical calculation.

6. Conclusions

In this paper, catalytic ignition experiments of the HAN/(Emim)(EtSO4) dual-mode ionic liquid monopropellant were carried out under the flow rates of 1~4 mL/min and 1~3 mL/min respectively using a model thruster without and with the convergent nozzle at a preheating temperature of 200 °C. From the measurements of temperature at different depths of the catalytic bed, the pressure of the combustion chamber, and the main components of the gaseous products and their corresponding concentrations, as well as theoretical calculation of CEA and GC analysis of exhaust gas, the following conclusions can be drawn:
(1)
When the propellant flows into the catalytic bed, the H2O component evaporates first, causing a small pressure peak in the combustion chamber pressure, which can be observed in a model thruster with the convergent nozzle.
(2)
Secondly the temperature curves appear in two rising stages respectively corresponding to the decomposition of the oxidant component HAN and the fuel component (Emim)(EtSO4) in both a model thruster without and with the convergent nozzle. In a model thruster with the convergent nozzle, the two rising stages are directly completed at the position where the propellant first contacts it after the propellant is injected into the catalytic bed. The HAN decomposes at the same depth in a model thruster without the convergent nozzle while the position (Emim)(EtSO4) decomposes will move downstream as the flow rate increases.
(3)
In addition, the decomposition of the HAN will produce the oxidizing gas NOx. Then (Emim)(EtSO4) starts to fully react with NOx, depleting NO immediately. In the meantime, the C element is oxidized to CO2 in a large amount, letting out plenty of heat. In this process CH4, CO, and SO2 are also produced. Following that, the temperature tends to be stable, NOx is completely reacted, SO2 is no longer generated, CH4 will slowly decrease and even disappear, and the concentrations of CO and CO2 gradually reach stability in the process of approaching the equilibrium.
(4)
When the catalytic ignition approaches equilibrium, the analytical results of GC are consistent with the trend of theoretical calculation by CEA. The ambient pressure has little influence on exhaust gas; however, the temperature is a significant factor. The contents of N2 and H2 occupy the majority, and that of CH4, CO2, and CO are determined by the temperature.

Author Contributions

Conceptualization, J.F., H.G., Z.Y. and S.L.; methodology, J.F. and Z.W.; formal analysis, J.F. and Z.Y.; investigation, J.F., Z.W., H.Y., H.G., Z.Y. and S.L.; resources, J.F. and Z.Y.; data curation, J.F.; visualization, J.F.; writing—original draft preparation, J.F.; writing—review and editing, J.F., H.Y., Z.Y. and S.L.; supervision, Z.Y. and S.L. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Rovey, J.L.; Lyne, C.T.; Mundahl, A.J.; Rasmont, N.; Glascock, M.S.; Wainwright, M.J.; Berg, S.P. Review of chemical-electric multimode space propulsion. In Proceedings of the AIAA Propulsion and Energy 2019 Forum, Indianapolis, IN, USA, 19–22 August 2019. [Google Scholar]
  2. Coleman, D.; Benedict, M.; Hrishikeshavan, V.; Chopra, I. Design, development, and flight-testing of a robotic hummingbird. In Proceedings of the American Helicopter Society 71st Annual Forum, Virginia Beach, VA, USA, 5–7 May 2015. [Google Scholar]
  3. Lazurenko, A.; Vial, V.; Bouchoule, A.; Skrylnikov, A.; Kozlov, V.; Kim, V. Dual-mode operation of stationary plasma thrusters. J. Propuls. Power 2006, 22, 38–475. [Google Scholar] [CrossRef]
  4. Rovey, J.L.; Lyne, C.T.; Mundahl, A.J.; Rasmont, N.; Glascock, M.S.; Wainwright, M.J.; Berg, S.P. Review of multimode space propulsion. Prog. Aerosp. Sci. 2020, 118, 100627. [Google Scholar] [CrossRef]
  5. Donius, B.R.; Rovey, J.L. Ionic liquid dual-mode spacecraft propulsion assessment. J. Spacecr. Rocket. 2011, 48, 110–123. [Google Scholar] [CrossRef] [Green Version]
  6. Zhang, Q.; Shreeve, J.N.M. Energetic ionic liquids as explosives and propellant fuels: A new journey of ionic liquid chemistry. Chem. Rev. 2014, 114, 10527–10574. [Google Scholar] [CrossRef] [PubMed]
  7. Donius, B.R.; Rovey, J.L. Analysis and prediction of dual-mode chemical and electric ionic liquid propulsion performance. In Proceedings of the 48th AIAA Aerospace Sciences Meeting Including the New Horizons Forum and Aerospace Exposition, Orlando, FL, USA, 4–7 January 2010. [Google Scholar]
  8. Romero-Sanz, I.; Bocanegra, R.; Fernandez De La Mora, J.; Gamero-Castano, M. Source of heavy molecular ions based on Taylor cones of ionic liquids operating in the pure ion evaporation regime. J. Appl. Phys. 2003, 94, 3599–3605. [Google Scholar] [CrossRef] [Green Version]
  9. Garoz, D.; Bueno, C.; Larriba, C.; Castro, S. Taylor cones of ionic liquids from capillary tubes as sources of pure ions: The role of surface tension and electrical conductivity. J. Appl. Phys. 2007, 102, 064913. [Google Scholar] [CrossRef]
  10. Sutton, G.P.; Biblarz, O. Rocket Propulsion Elements; John Wiley & Sons: New York, NY, USA, 2016. [Google Scholar]
  11. Berg, S.P.; Rovey, J.L. Dual-mode propellant properties and performance analysis of energetic ionic liquids. In Proceedings of the 50th AIAA Aerospace Sciences Meeting including the New Horizons Forum and Aerospace Exposition, Nashville, TN, USA, 9–12 January 2012. [Google Scholar]
  12. Berg, S.P.; Rovey, J.L. Ignition evaluation of monopropellant blends of HAN and imidazole-based ionic liquid fuels. In Proceedings of the 50th AIAA Aerospace Sciences Meeting including the New Horizons Forum and Aerospace Exposition, Nashville, TN, USA, 9–12 January 2012. [Google Scholar]
  13. Berg, S.P.; Rovey, J.L.; Prince, B.; Miller, S.; Bemish, R. Electrospray of an energetic ionic liquid monopropellant for multi-mode micropropulsion applications. In Proceedings of the 51st AIAA/SAE/ASEE Joint Propulsion Conference, Orlando, FL, USA, 27–29 July 2015. [Google Scholar]
  14. Berg, S.P.; Rovey, J.L. Decomposition of a double salt ionic liquid monopropellant on heated metallic surfaces. In Proceedings of the 52nd AIAA/SAE/ASEE Joint Propulsion Conference, Salt Lake City, UT, USA, 25–27 July 2016. [Google Scholar]
  15. Mundahl, A.J.; Rovey, J.L.; Berg, S.P. Linear burn rate of monopropellant for multi-mode micropropulsion. In Proceedings of the 2018 Joint Propulsion Conference, Cincinnati, OH, USA, 9–11 July 2018. [Google Scholar]
  16. Berg, S.P.; Rovey, J.L. Decomposition of a Double Salt Ionic Liquid Monopropellant in a Microtube for Multi-Mode Micropropulsion Applications. In Proceedings of the 53rd AIAA/SAE/ASEE Joint Propulsion Conference, Atlanta, GA, USA, 10–12 July 2017. [Google Scholar]
  17. Berg, S.P.; Glascock, M.S.; Cooper, M.; Rovey, J.L. Multimode Integrated Monopropellant Electrospray Thruster Testing Results: Chemical Mode. In Proceedings of the NASA In-Space Chemical Propulsion Technical Interchange Meeting, Online, 14–17 September 2020. [Google Scholar]
  18. Lyne, C.T.; Rovey, J.; Berg, S.P. Monopropellant-Electrospray Multimode Thruster Testing Results: Electrospray Mode. In Proceedings of the AIAA Propulsion and Energy 2021 Forum, Virtual Event, 9–11 August 2021. [Google Scholar]
  19. Wang, W.; Ma, Z.; Cong, W.; Zhang, W.; Xia, L.; Wang, X. Studies on Synthesis, Characterization and Catalytic Decomposition of Multitask Mode Ionic Liquid Propellant. J. Propuls. Technol. 2020, 41, 455–460. (In Chinese) [Google Scholar]
  20. Gao, H.; Li, S.; Yao, Z.; Li, S. Experimental Study on Thermal and Catalytic Decomposition of a Dual-Mode Ionic Liquid Propellant. E3S Web Conf. 2021, 257, 01041. [Google Scholar] [CrossRef]
  21. Sharma, A.; Adducci, A.C.; Rovey, J.; Ma, C.; Ryan, C.N.; Berg, S. Green Ionic Liquid Multimode Monopropellant Based Chemical Micro-thruster. In Proceedings of the AIAA SCITECH 2022 Forum, San Diego, CA, USA, 3–7 January 2022. [Google Scholar]
  22. Li, S.; Yan, H.; Wang, Z.; Tang, Y.; Yao, Z.; Li, S. Catalytic Decomposition and Burning of a Dual-Mode Ionic Liquid Propellant. Energy Fuels 2021, 35, 18716–18725. [Google Scholar] [CrossRef]
  23. Tang, Y.; Li, S.; Yao, Z.; Huang, B.; Li, S. Ignition of an ionic dual-mode monopropellant using a microwave plasma torch. Proc. Combust. Inst. 2022, in press. [Google Scholar] [CrossRef]
  24. Fang, J.; Wang, Z.; Yan, H.; Gao, H.; Yao, Z.; Li, S. Catalytic Ignition Characteristics of Dual-mode Ionic Liquid Propellant under Vacuum Condition. J. Rocket. Propuls. 2022, 48, 1–8. (In Chinese) [Google Scholar]
  25. Schneider, S.; Hawkins, T.; Rosander, M.; Vaghjiani, G.; Chambreau, S.; Drake, G. Ionic liquids as hypergolic fuels. Energy Fuels 2008, 22, 2871–2872. [Google Scholar] [CrossRef]
  26. Weng, X.; Tang, C.; Li, J.; Zhang, Q.; Huang, Z. Coulomb explosion and ultra-fast hypergolic ignition of borohydride-rich ionic liquids with WFNA. Combust. Flame 2018, 194, 464–471. [Google Scholar] [CrossRef]
  27. McBride, B.J.; Gordon, S. Computer Program for the Calculation of Complex Chemical Equilibrium Compositions and Applications II. User’s Manual and Program Description; National Aeronautics and Space Administration (NASA): Washington, DC, USA, 1996. Available online: https://ntrs.nasa.gov/citations/19960044559 (accessed on 16 June 2021).
Figure 1. Model Thruster and experimental Setup: (a) model thruster; (b) experimental stand.
Figure 1. Model Thruster and experimental Setup: (a) model thruster; (b) experimental stand.
Energies 15 08730 g001
Figure 2. The catalytic and the convergent nozzle: (a) catalytic bed; (b) convergent nozzle; (c) section view of the convergent nozzle.
Figure 2. The catalytic and the convergent nozzle: (a) catalytic bed; (b) convergent nozzle; (c) section view of the convergent nozzle.
Energies 15 08730 g002
Figure 3. Preheating temperature distribution at different depths of the catalytic bed.
Figure 3. Preheating temperature distribution at different depths of the catalytic bed.
Energies 15 08730 g003
Figure 4. Temperature curves of the catalytic bed in a model thruster without the convergent nozzle at each flow rate: (a) 1 mL/min; (b) 2 mL/min; (c) 3 mL/min; (d) 4 mL/min.
Figure 4. Temperature curves of the catalytic bed in a model thruster without the convergent nozzle at each flow rate: (a) 1 mL/min; (b) 2 mL/min; (c) 3 mL/min; (d) 4 mL/min.
Energies 15 08730 g004
Figure 5. Flue gas analysis curves of the catalytic ignition process in a model thruster without the convergent nozzle at each flow rate: (a) 1 mL/min; (b) 2 mL/min; (c) 3 mL/min; (d) 4 mL/min.
Figure 5. Flue gas analysis curves of the catalytic ignition process in a model thruster without the convergent nozzle at each flow rate: (a) 1 mL/min; (b) 2 mL/min; (c) 3 mL/min; (d) 4 mL/min.
Energies 15 08730 g005
Figure 6. Temperature and pressure curves of a model thruster with the convergent nozzle at 1 mL/min flow rate.
Figure 6. Temperature and pressure curves of a model thruster with the convergent nozzle at 1 mL/min flow rate.
Energies 15 08730 g006
Figure 7. Temperature and pressure curve of a model thruster with the convergent nozzle at a 2 mL/min flow rate.
Figure 7. Temperature and pressure curve of a model thruster with the convergent nozzle at a 2 mL/min flow rate.
Energies 15 08730 g007
Figure 8. Temperature and pressure curve of a model thruster with the convergent nozzle at a 3 mL/min flow rate.
Figure 8. Temperature and pressure curve of a model thruster with the convergent nozzle at a 3 mL/min flow rate.
Energies 15 08730 g008
Figure 9. Flue gas analysis curves of the catalytic ignition process in a model thruster with the convergent nozzle at each flow rate: (a) 1 mL/min; (b) 2 mL/min; (c) 3 mL/min.
Figure 9. Flue gas analysis curves of the catalytic ignition process in a model thruster with the convergent nozzle at each flow rate: (a) 1 mL/min; (b) 2 mL/min; (c) 3 mL/min.
Energies 15 08730 g009
Figure 10. CEA analysis results at: (a) different pressures and; (b) different temperatures.
Figure 10. CEA analysis results at: (a) different pressures and; (b) different temperatures.
Energies 15 08730 g010
Figure 11. Temperature and pressure curves of a model thruster without the convergent nozzle carrying on the catalytic ignition experiment in the vacuum environment.
Figure 11. Temperature and pressure curves of a model thruster without the convergent nozzle carrying on the catalytic ignition experiment in the vacuum environment.
Energies 15 08730 g011
Figure 12. The results of GC analysis in different pressure environments: (a) vacuum environment; (b) atmospheric environment; (c) high chamber pressure environment.
Figure 12. The results of GC analysis in different pressure environments: (a) vacuum environment; (b) atmospheric environment; (c) high chamber pressure environment.
Energies 15 08730 g012
Figure 13. Comparison of theoretical calculation and experimental results.
Figure 13. Comparison of theoretical calculation and experimental results.
Energies 15 08730 g013
Table 1. The specific measurement range of the corresponding components.
Table 1. The specific measurement range of the corresponding components.
Gaseous ProductConcentration RangeCalibration Result
Nominal Value ± Tolerance ValueActual Value
O20–20.9%10.01 ± 0.2%10.05%
CO (%)0–10%5.02 ± 0.15%5.02%
CO (ppm)0–10,000 ppm813 ± 40 ppm817 ppm
CO20–20%9.93 ± 0.3%9.95%
CH40–2.5%1.973 ± 0.06%1.988%
NO0–4000 pm80.1 ± 5 ppm81 ppm
NO20–1000 pm50 ± 5 ppm51 ppm
SO20–10,000 pm483.4 ± 25 ppm486 ppm
Table 2. Two rising stages of the temperature curves of the catalytic bed of a model thruster without the convergent nozzle at the flow rate of 1–4 mL/min.
Table 2. Two rising stages of the temperature curves of the catalytic bed of a model thruster without the convergent nozzle at the flow rate of 1–4 mL/min.
Flow RateThe First Rising StageThe Second Rising StageThe Maximum Temperature
1 mL/min200–310 °C, TC0
200–240 °C, TC1
320–670 °C, TC0
280–540 °C, TC1
990 °C, TC0
2 mL/min200–320 °C, TC0
200–220 °C, TC1
300–780 °C, TC0
210–770 °C, TC1
880 °C, TC1
3 mL/min200–300 °C, TC0
200–220 °C, TC1
around 310 °C, TC0
260–1050 °C, TC1
1070 °C, TC1
4 mL/min200–290 °C, TC0
200–220 °C, TC1
290–160 °C, TC0
250–1100 °C, TC1
1230 °C, TC1
Table 3. Two rising stages of the temperature curves of a model thruster with the convergent nozzle at the flow rate of 1~3 mL/min.
Table 3. Two rising stages of the temperature curves of a model thruster with the convergent nozzle at the flow rate of 1~3 mL/min.
Flow RateThe First Rising StageThe Second Rising StageThe Maximum Temperature
1 mL/min200–310 °C, TC0350–800 °C, TC0950 °C, TC0
2 mL/min200–330 °C, TC0350–930 °C, TC01100 °C, TC0
3 mL/min200–350 °C, TC0380–920 °C, TC01030 °C, TC0
Table 4. The calculation value and the normalized value of CEA calculation at different temperatures.
Table 4. The calculation value and the normalized value of CEA calculation at different temperatures.
T (K)Calculation Value (%)Normalized Value (%)
CH4COCO2H2N2Total 1H2OCH4COCO2H2N2
4006.566012.630.04415.62534.86549.81818.833036.2250.12644.816
5009.9490.00216.6580.60716.55843.77446.25422.7280.00538.0551.38737.826
60011.6050.05819.8813.44517.01452.00341.94822.3160.11238.236.62532.717
70010.1570.71621.73711.03916.61360.26235.64616.8551.18836.07118.31827.568
8005.3763.95920.66422.75715.29368.04928.1857.95.81830.36633.44222.474
9000.9379.61117.02530.99914.06872.6423.8991.2913.23123.43842.67519.367
10000.05812.53414.49230.83213.82771.74324.8610.08117.47120.242.97619.273
11000.00414.28412.75629.25113.81370.10826.5010.00620.37418.19541.72319.702
12000.00115.65411.37927.89813.81268.74427.8690.00122.77116.55340.58220.092
1300016.75610.26726.81213.8167.64528.976024.7715.17839.63620.415
1400017.6559.35425.96213.80666.77729.872026.43914.00838.87920.675
1500018.4028.58525.33913.79566.12130.594027.83112.98438.32220.863
1600019.0387.91324.94713.77465.67231.16028.99012.04937.98720.974
1 This is the sum of the theoretical value of CH4, CO, CO2, H2, and N2.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Fang, J.; Wang, Z.; Yan, H.; Gao, H.; Yao, Z.; Li, S. Experimental Study on the Catalytic Ignition Characteristics of a Dual-Mode Ionic Liquid Propellant in Model Thrusters. Energies 2022, 15, 8730. https://doi.org/10.3390/en15228730

AMA Style

Fang J, Wang Z, Yan H, Gao H, Yao Z, Li S. Experimental Study on the Catalytic Ignition Characteristics of a Dual-Mode Ionic Liquid Propellant in Model Thrusters. Energies. 2022; 15(22):8730. https://doi.org/10.3390/en15228730

Chicago/Turabian Style

Fang, Jie, Zun Wang, Hao Yan, He Gao, Zhaopu Yao, and Shuiqing Li. 2022. "Experimental Study on the Catalytic Ignition Characteristics of a Dual-Mode Ionic Liquid Propellant in Model Thrusters" Energies 15, no. 22: 8730. https://doi.org/10.3390/en15228730

APA Style

Fang, J., Wang, Z., Yan, H., Gao, H., Yao, Z., & Li, S. (2022). Experimental Study on the Catalytic Ignition Characteristics of a Dual-Mode Ionic Liquid Propellant in Model Thrusters. Energies, 15(22), 8730. https://doi.org/10.3390/en15228730

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics