Article

A Fault-Tolerant Strategy for Three-Level Flying-Capacitor DC/DC Converter in Spacecraft Power System †

1
Beijing Institute of Spacecraft System Engineering, Beijing 100094, China
2
School of Mechanical Engineering and Automation, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
3
Department of Electrical Engineering, China University of Petroleum (East China), Qingdao 266580, China
*
Author to whom correspondence should be addressed.
This paper is an extended version of our paper published in 2022 IEEE International Power Electronics and Application Conference and Exposition (PEAC), Guangzhou, China, 4–7 November 2022; pp. 1620–1625.
Energies 2023, 16(1), 556; https://doi.org/10.3390/en16010556
Submission received: 21 November 2022 / Revised: 24 December 2022 / Accepted: 26 December 2022 / Published: 3 January 2023

Abstract

:
With the development of space exploration, high-power and high-voltage power systems are essential for future spacecraft applications. Because of the effects of space radiation such as single event burnout (SEB), the rated voltage of power devices in converters for a spacecraft power system is limited to a level much lower than that for traditional ground applications. Thus, multi-level DC/DC converters are good choices for high-voltage applications in spacecraft. In this paper, a fault-tolerant strategy is proposed for a three-level flying capacitor DC/DC converter to increase the reliability with minimal cost. There is no extra hardware needed for the proposed strategy; the fault tolerance of the converter is only achieved by changing the software control strategy. A stage analysis of the proposed strategy is provided in detail for different fault locations and ratios between the input and output voltage. Finally, a simulation model and prototype are built to verify the effectiveness of the proposed strategy.

1. Introduction

The architecture of a high-power spacecraft distributed power system is shown in Figure 1. The spacecraft power system is a typical DC power system [1,2]. It consists of solar arrays, batteries, a fuel cell, flying wheel, power converters, etc. The solar arrays provide the power for the load and charge the battery during the sunlight period of the orbit. Storages such as batteries provide the power for the load during the eclipse period of the orbit. The power converters are used to regulate the DC bus voltage and control the battery charging and discharging. With the development of space exploration, the power capacity of spacecraft has become larger and larger, and the voltage level of the spacecraft power system has become higher and higher. Currently, high voltage and high power are the trends and necessary factors for a spacecraft power system to meet the requirements of future spacecraft, such as high-power SAR satellites, electric propulsion spacecraft, deep space spacecraft, space stations, and space solar energy power stations, etc. [3] The power ratings of these spacecraft will need to be larger than 100 kW, and the voltage level will need to be higher than 1000 V. However, the current power converters cannot meet the requirements of this high-voltage application. The characteristics of the power device in space are obviously different from that on the ground. Due to space radiation effects such as single event burnout, the high-voltage power device is the main limitation for spacecraft power converters. Currently, the available voltage of power devices such as power MOSFETs for spacecraft power converters is lower than 500 V. However, the requirement of the output voltage of converters is much higher than 500 V for future space applications. In order to solve the mismatch between future high-voltage applications and the available low-voltage power devices, the multi-level DC/DC converter is a better solution for these high-voltage applications with the voltage limitation of the power devices. Even though they are not used in traditional spacecraft power systems in which the highest DC bus voltage is 100 V, these converters are widely used in ground high-voltage applications. The voltage stress of the power devices in a multi-level DC/DC converter can clearly be reduced [4,5,6,7,8,9,10]. For multi-level DC/DC converters, the number of power devices is relatively larger than the traditional two-level converter. Each failure of the power device may cause the output interruption of the converter, so the reliability of the multi-level DC/DC converter is relatively low without a fault-tolerant strategy [11,12,13,14,15,16]. In addition, the reliability of the converter is very important for the spacecraft. The failure of the converter will result in huge losses, especially for an unmanned spacecraft. Thus, the fault-tolerant strategy is very important for the multi-level converter in a spacecraft power system. Fault-tolerant schemes of multi-level DC/DC converters have been proposed by researchers [14,15,16,17,18,19,20]. The redundant subsystem, units, circuits, or devices have been added to multi-level converters to improve their reliability [14,15,17,18]. The fuse is a common component that is used to isolate the short-circuit fault parts of the converter. The main disadvantage of the fuses is that the blowing time of a fuse is difficult to control. Moreover, the use of a fuse will increase the parasitic inductance of the commutation loops of the converter, and larger parasitic inductance causes a higher voltage stress, which reduces the reliability of power devices [19,20]. Additional hardware is needed for these former methods. However, the additional hardware increases the mass of the converter, which results in an obviously higher cost of the launch. For space application, the limitation of the mass of converters is extremely strict. A three-level flying capacitor DC/DC converter is the typical multi-level DC/DC converter. A fault-tolerant control strategy for three-level flying capacitor DC/DC converters is proposed in this paper. The reliability of the three-level DC/DC converter is improved with minimal cost. The fault tolerance of the converter is achieved by only changing the software strategy, and no extra hardware is needed. The concept of the fault-tolerant strategy can also be applied in other multi-level converters.
In Section 2, the control scheme of the fault-tolerant strategy for a three-level flying capacitor DC/DC converter is introduced. In Section 3, the stage analysis of the converter under short-circuit fault conditions is given in detail. In Section 4, the proposed strategy under different conditions is verified by experiments and simulations. Finally, the conclusions are summarized.

2. Control Scheme of Fault-Tolerant Strategy for Three-Level Flying Capacitor DC/DC Converter

In order to achieve the fault-tolerant operation of the three-level flying capacitor DC/DC converter after a short-circuit fault of the power devices, a seamless transfer control from three-level mode to two-level mode is designed. Before the fault, the converter operates in three-level mode, and after the fault, the converter operates in two-level mode. The control scheme of the proposed fault-tolerant strategy for a three-level flying capacitor DC/DC converter is shown in Figure 2.
The fault-tolerant strategy consists of three loops, including a three-level voltage regulation loop, a flying capacitor voltage loop, and a two-level voltage regulation loop. When the power devices of the converter are normal, the output voltage and flying capacitor voltage are regulated by a three-level voltage regulation loop. Output voltage and flying capacitor voltage are two control targets for the three-level voltage regulation loop. The reference of flying capacitor voltage is half of the reference of the output voltage of the converter. When a short-circuit fault of the power device occurs, the converter is regulated by the flying capacitor voltage loop after the short-circuit fault of the power device is detected. If a short-circuit fault of inner switch S2 or S3 occurs, the voltage reference of the flying capacitor changes from half of the output voltage to zero. The normal inner power devices are opened immediately, and the driver signals of the normal inner switches are set as low. If a short-circuit fault of outer switch S1 or S4 occurs, the reference of the flying capacitor voltage changes from half of the output voltage to the output voltage, and the driver signals of the normal outer switches are set as high. When the voltage of the flying capacitor reaches the reference value, the converter changes its mode to the two-level mode. If the inner switch is at fault, the driver of the other inner switch is set as high in the two-level mode. The driver signals of the two outer switches operate in the complementary state. If the outer switch is at fault, the driver of the other outer switch is set as high. The driver signals of the two inner switches operate in the complementary state.

3. Analysis of Operation Modes for the Converter under Short-Circuit Fault Conditions

According to the analysis of the flying capacitor three-level DC/DC converter, the operation stages of the converter are different between the situation in which the ratio of the input and output voltage is smaller than 0.5 (VL < 0.5 VH) and the situation in which the ratio is larger than 0.5 (VL > 0.5 VH).
The diagram in Figure 3 shows the key quantity for the situation in which the short-circuit fault occurs in switch S3 when the ratio of the input and output voltage is smaller than 0.5 (VL < 0.5 VH). When the short-circuit fault of switch S3 is detected by the detection circuit, the converter is regulated from the three-level mode to the flying capacitor voltage control mode. The reference of the flying capacitor voltage decreases from half of the output voltage VH to zero. The voltage of the flying capacitor is changed by the flying capacitor voltage loop from half of the output voltage to zero during this stage. After the voltage of the flying capacitor is detected to have reached zero, the converter finishes the flying capacitor voltage control mode and begins to operate in two-level mode.
The analysis of operation stages under this fault situation is shown in Figure 4. The g1, g2, g3, and g4 are gate drivers of switches S1, S2, S3, and S4, respectively. When VL < 0.5 VH, the duty cycle of inner switches g3 and g4 is larger than 0.5. The three-level mode is the pre-fault mode. The stages of the three-level mode are shown in Figure 5. There are four stages in the three-level mode. In the three-level mode, the driver signal of g1 and g4 are complementary, and the driver signal of g2 and g3 are complementary.
The stages during the flying capacitor voltage control mode are shown in Figure 6. There are also three stages after the short-circuit fault occurs. In Stage V, S3 is short-circuited and S2 turns on, then the flying capacitor is short-circuited. There is a large current spike occurring in S2, so the fault is detected. After the fault is detected, the converter operates in Stage VI and VIII; in these two stages, g4 is in the PWM state, and the values of g1, g2, and g3 are 0 when the short-circuit fault occurs in S3. Similarly, g1 is in the PWM state, and the values of g2, g3, and g4 are 0 when the short-circuit fault occurs in switch S2. The two-level mode is the post-fault mode. In the two-level mode, the driver signal of g1 and g4 are complementary, and g2 is set as 1 when the short-circuit fault occurs in switch S3. Similarly, g3 is set as 1 when S2 is where the fault occurs.
The diagram in Figure 7 shows the key quantities under the situation in which the short-circuit fault occurs in the outer switch S4 when VL is lower than 0.5 VH. Before the fault occurs, the converter operates in three-level mode. When the short-circuit fault of the switch S4 is detected, the converter begins to operate in flying capacitor voltage control mode. The flying capacitor voltage is regulated gradually from half of the output voltage to output voltage. When the flying capacitor voltage reaches the output voltage, the converter turns to operate in two-level mode.
The stage analysis in this situation is shown in Figure 8. The stages of the three-level mode are the same as those in which the short-circuit fault of S3 occurs. The stages of the flying capacitor voltage control mode after a short-circuit fault are shown in Figure 9. There are three stages after the short-circuit fault occurs in the outer switches. In Stage V of the flying capacitor voltage mode, g4 is short-circuited and g1 turns on; then the output capacitor is connected directly with the flying capacitor. Due to the existence of the voltage difference between the output voltage and the flying capacitor voltage, there is a current spike occurring in S1, and the fault can be detected. After Stage V, the converter operates in Stages VI and VII. In these two stages, g3 is in the PWM state, and g1, g2, and g4 are 0 when the short-circuit fault occurs in S4. Similarly, g2 is in the PWM state, and g1, g3, and g4 are 0 when the short-circuit fault occurs in S1. In the two-level mode, the driver signal of g2 and g3 are complementary, and g1 is set as 1 when the fault occurs in S4. Similarly, g4 is set as 1 when the fault occurs in S1.
Then the situation when VL is higher than 0.5 VH is analyzed in detail. The stage analysis is shown in Figure 10 for when S3 is short-circuited in this situation. This situation is different from the situation when VL is lower than 0.5 VH. The duty cycle of g3 and g4 is less than 0.5.
When the short-circuit fault of S3 is detected, the converter is regulated by the flying capacitor voltage control loop. Then S4 is opened. Because VL > 0.5 VH and the initial value of vfly is half of vH, inequality (1) can be derived at the beginning of the fault. The voltage difference between the inductor is always positive. It should be noticed that if inequality (2) holds, the current of the inductor will continue to increase during Stage VI. When vfly is lower than (vHvL), the converter operates in Stages VII and VIII. When the flying capacitor voltage reaches 0, the converter turns into the two-level mode, and the S2 is closed.
v L > v H v f l y     ( v L > 0.5 v H , V f l y = 0.5 v H )
v f l y > v H v L
The proper inductance value of the inductor L should be designed, and additional an over-current protection method should be considered. The flying capacitor voltage and inductor current can be calculated by (3). The current spike analysis in this situation when S3 is short-circuited is shown in Figure 11.
{ v f l y ( t ) = I L L C C sin ( 1 L C t ) + ( V f l y V H + V L ) cos ( 1 L C t ) + ( V H V L ) i L ( t ) = I L cos ( 1 L C t ) ( V f l y V H + V L ) C L C sin ( 1 L C t )
where vfly is the flying capacitor voltage, VH is the output voltage, VL is the input voltage, L is the inductance of the input inductor, C is the capacitance of the flying capacitor, iL is the current value of the inductor, and IL is the initial value of the inductor current. If the output voltage is 100 V, the input voltage is 80 V, the inductor is 1 mH, and the initial current of the inductor is 10 A, then it can be calculated that the maximum inductor current is 17.2 A. The maximum current under different levels of inductance when S3 is short-circuited is shown in Figure 12.
The current spike analysis when S4 is short-circuited is shown in Figure 13. When the short-circuit fault of S4 is detected, S3 is turned off. Because vL is larger than 0.5 VH and the initial value of Vfly is half of VH, inequality (4) can be derived at the beginning of the fault. The voltage difference between the inductor is always positive. It should be noticed that if inequality (5) holds, the current of the inductor will continue to increase during Stage VI. When vfly is higher than 0.5 VH, the converter operates in Stages VII and VIII.
v L > v f l y     ( v L > 0.5 v H , V f l y = 0.5 v H )
v f l y < 0.5 v H
When the voltage of the flying capacitor voltage reaches VH, S1 is turned off. The proper inductance should also be designed carefully. The flying capacitor voltage and inductor current can be calculated by (4). The current spike analysis is given in Figure 14. If we take the same parameters as the situation when S3 is faulty, the maximum inductor current is 17.2 A. The maximum current under different levels of inductance when S4 is short-circuited is shown in Figure 15.
{ v f l y ( t ) = I L L C C sin ( 1 L C t ) + ( V f l y V L ) cos ( 1 L C t ) + ( V L ) i L ( t ) = I L cos ( 1 L C t ) ( V f l y V L ) C L C sin ( 1 L C t )
The parameters of the flying capacitor DC/DC converter can be calculated as below. According to the stage analysis of the circuit, the inductance of the input inductor is derived by (7), the capacitance of the flying capacitor is derived by (8), and the capacitance of the output capacitor is derived by (9).
L I N = { ( U o 2 U I N ) ( 1 D ) δ I I i n f s     ( D > 0.5 ) ( U I N U o 2 ) D δ I I i n f s     ( D < 0.5 )
C f l y = { I I N ( 1 D ) δ f U o 2 f s     ( D > 0.5 ) I I N D δ f U o 2 f s     ( D < 0.5 )
C o = I o δ o U o f s
where the output voltage Uo is 100 V, the input voltage UIN is 30~80 V, the switching frequency fs is 10,000 Hz, the duty cycle D is 0.2~0.7, the input current IIN is 33 A, the output current Io is 10 A, the ripple ratio of the input current δI is 0.02, the ripple ratio of the flying capacitor voltage δf is 0.1, and the ripple ratio of the output capacitor voltage δo is 0.01. Then the inductor is 0.9 mH, the flying capacitor is 200 μF, and the output capacitor is 1 mF. With the consideration of the current spike analysis after a short-circuit fault in the simulation, the inductance of the inductor is chosen as 1 mH, and the capacitances of the flying capacitor and the output capacitor are chosen as 200 μF and 1 mF, respectively.

4. Simulation and Experiment Verifications of the Fault-Tolerant Strategy

In order to verify the proposed fault-tolerant strategy, the simulation model of the flying capacitor three-level DC/DC converter based on PSIM was built. In the model, the rated power of the flying capacitor three-level converter is 1 kW. The output voltage of the converter is 100 V. The two types of input voltage are considered, including 30 V (VL<0.5 VH) and 80 V (VL > 0.5 VH). The inductance of the inductor is 1 mH. The capacitance of the flying capacitor is 200 uF, and the capacitance of the output capacitor is 1 mF. The parameters of the simulation are shown in Table 1.
The simulation waveforms when a short-circuit fault occurs in outer switch S4 under two load conditions are shown in Figure 16. It can be seen that the output voltage of the converter is uninterruptible when a short-circuit fault of S4 occurs. The mode transfer after the fault is seamless.
The simulation results when the input voltage is lower than half of the output voltage are shown in Figure 17. The waveforms when a short-circuit fault occurs in inner switch S3 under different load conditions are shown in Figure 17a,b. The two load conditions are 100 W for a light load and 1000 W for a heavy load. It can be seen that the output voltage of the converter is uninterruptible after the S3 fault occurs. The spike of the current and voltage is in the normal range during the mode transition after the fault.
The simulation results when the input voltage is higher than half of the output voltage are shown in Figure 18 and Figure 19. The waveforms when a short-circuit fault occurs in S3 under two different load conditions including a light load and a heavy load are shown in Figure 18a,b, and the waveforms when a short-circuit fault occurs in S4 under two different load conditions are shown in Figure 19a,b. It can also be seen that the output voltage is uninterruptible when two types of faults occur. The spike and surge of the current and voltage are also in the normal range.
The prototype of the three-level flying capacitor DC/DC converter is built to verify the fault-tolerant strategy. The parameters of the prototype are shown in Table 2.
The waveform when the short-circuit fault of S3 occurs is shown in Figure 20a. CH1 is the output voltage of the converter. CH2 is the flying capacitor voltage. CH3 is the trigger signal. CH4 is the driver signal of the power switch S3. The waveform of the three-level mode before the fault occurs is shown in Figure 20b. The waveform during the fault is shown in Figure 20c. It can be seen that the output voltage is uninterruptible and the flying capacitor voltage is regulated from 16 V to 0. The waveform of the two-level mode after the fault occurs is shown in Figure 20d. The waveform when the short-circuit fault of S4 occurs is shown in Figure 21a. The waveform before an S4 fault is shown in Figure 21b. The waveform during the fault is shown in Figure 21c. It can be seen that the output voltage is uninterruptible and the flying capacitor voltage is regulated from 16 V to 32 V. After the S4 fault, the waveform is shown in Figure 21d.

5. Conclusions

In order to improve the reliability of converters for the interface of the PV, battery, or other sources in spacecraft power systems for future high-voltage application, the fault-tolerant strategy of a three-level flying capacitor DC/DC converter is proposed in this paper. If a short-circuit fault occurs in the power devices, the converter can provide uninterruptible power for the load. It can turn from the three-level mode to the two-level mode, and during the mode transition, the voltage of the flying capacitor is regulated to the different target value based on the different fault locations. There is no extra hardware needed for this proposed strategy; the fault tolerance of the converter is only achieved by changing the software control strategy, and the reliability of the converter is improved with minimal cost. The stage analysis of the three-level converter is provided in detail. Different ratios between the input and output voltage and different fault locations are considered. Finally, a simulation model and prototype of the converter with the fault-tolerant strategy are built to verify the proposed strategy. The results show the fault tolerance operation of the converter is achieved after a short-circuit fault occurs.

Author Contributions

Conceptualization, H.L.; methodology, H.L., X.Z., Z.L. and Y.Z.; validation, H.L., Y.G. and L.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This work is supported by the National Natural Science Foundation of China (52007007).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Zhang, X.; Li, H. Design of Software Defined Spacecraft Distributed Power Supply System. Spacecr. Eng. 2020, 29, 51–58. [Google Scholar]
  2. Zhang, M.; Liu, Y.; Li, H.; Zhang, W.; Zhang, X.; Xia, N.; Zhu, L.; Mu, H.; Liu, Z. Design of 100kW Distributed Reconfigurable Electrical Power System for Spacecraft. Spacecr. Eng. 2021, 30, 86–94. [Google Scholar]
  3. Bekemans, M.; Bronchart, F.; Scalais, T.; Franke, A. Configurable High Voltage Power Supply for Full Electric Propulsion Spacecraft. In Proceedings of the 2019 European Space Power Conference (ESPC 2019), Juan-les-Pins, France, 30 September–4 October 2019. [Google Scholar] [CrossRef]
  4. Dusmez, S.; Hasanzadeh, A.; Khaligh, A. Comparative Analysis of Bidirectional Three-Level DC–DC Converter for Automotive Applications. IEEE Trans. Ind. Electron. 2014, 62, 3305–3315. [Google Scholar] [CrossRef]
  5. Ruan, X.; Li, B.; Chen, Q.; Tan, S.-C.; Tse, C.K. Fundamental considerations of three-level DC–DC converters: Topologies, analyses, and control. IEEE Trans. Circuits Syst. I Regul. Pap. 2008, 55, 3733–3743. [Google Scholar] [CrossRef]
  6. Kesarwani, K.; Stauth, J.T. Resonant and multi-mode operation of flying capacitor multi-level DC-DC converters. In Proceedings of the 2015 IEEE 16th Workshop on Control and Modeling for Power Electronics (COMPEL), Vancouver, BC, Canada, 12–15 July 2015; pp. 1–8. [Google Scholar]
  7. Tesaki, K.; Ishida, Y.; Hagiwara, M. Control and Experimental Verification of a Bidirectional Non-isolated DC-DC Converter Based on Three-level Flying-Capacitor Converters. IEEJ J. Ind. Appl. 2021, 10, 114–123. [Google Scholar] [CrossRef]
  8. Cuzner, R.M.; Bendre, A.R.; Faill, P.J.; Semenov, B. Implementation of a non-isolated three level DC/DC converter suitable for high power systems. In Proceedings of the 2007 IEEE Industry Applications Annual Meeting, New Orleans, LA, USA, 23–27 September 2007; pp. 2001–2008. [Google Scholar]
  9. Choi, M.; Jeong, D.K. Design of High Step-Down Ratio Isolated Three-Level Half-Bridge DC–DC Converter With Balanced Voltage on Flying Capacitor. IEEE Trans. Power Electron. 2022, 37, 10213–10225. [Google Scholar] [CrossRef]
  10. Zhong, Z.; Chen, Y.; Zhang, P.; Kang, Y. A cost-effective circuit for three-level flying-capacitor buck converter combining the soft-start, flying capacitor pre-charging and snubber functions. In Proceedings of the 2014 IEEE Energy Conversion Congress and Exposition (ECCE), Pittsburgh, PA, USA, 14–18 September 2014; pp. 3658–3663. [Google Scholar] [CrossRef]
  11. Zhang, W.; Xu, D.; Enjeti, P.N.; Li, H.; Hawke, J.T.; Krishnamoorthy, H.S. Survey on Fault-Tolerant Techniques for Power Electronic Converters. IEEE Trans. Power Electron. 2014, 29, 6319–6331. [Google Scholar] [CrossRef]
  12. Kumar, G.K.; Elangovan, D. Review on fault-diagnosis and fault-tolerance for DC–DC converters. IET Power Electron. 2020, 13, 1–13. [Google Scholar] [CrossRef]
  13. Bento, F.; Cardoso, A.J.M. A comprehensive survey on fault diagnosis and fault tolerance of DC-DC converters. Chin. J. Electr. Eng. 2018, 4, 1–12. [Google Scholar] [CrossRef]
  14. Gleissner, M.; Bakran, M.M. Design and control of fault-tolerant nonisolated multiphase multilevel DC–DC converters for automotive power systems. IEEE Trans. Ind. Appl. 2015, 52, 1785–1795. [Google Scholar]
  15. Pazouki, E.; Sozer, Y.; De Abreu-Garcia, J.A. Fault Diagnosis and Fault-Tolerant Control Operation of Nonisolated DC–DC Converters. IEEE Trans. Ind. Appl. 2017, 54, 310–320. [Google Scholar] [CrossRef]
  16. Wang, H.; Li, H.; Yan, C.; Xu, D. A Short-Circuit Fault-Tolerant Strategy for Three-Phase Four-Wire Flying Capacitor Three-Level Inverters. In Proceedings of the 2019 IEEE 10th International Symposium on Power Electronics for Distributed Generation Systems (PEDG), Xi’an, China, 3–6 June 2019; pp. 781–786. [Google Scholar] [CrossRef]
  17. Xu, S.; Zhang, J.; Hang, J. Investigation of a Fault-Tolerant Three-Level T-Type Inverter System. IEEE Trans. Ind. Appl. 2017, 53, 4613–4623. [Google Scholar] [CrossRef]
  18. Sheng, H.; Wang, F.; Tipton, C.W., IV. A fault detection and protection scheme for three-level DC–DC converters based on monitoring flying capacitor voltage. IEEE Trans. Power Electron. 2011, 27, 685–697. [Google Scholar] [CrossRef]
  19. Choi, U.M.; Blaabjerg, F.; Lee, K.B. Study and Handling "Methods of Power IGBT Module Failures in Power Electronic Converter Systems. IEEE Trans. Power Electron. 2015, 30, 2517–2533. [Google Scholar] [CrossRef]
  20. Soon, J.L.; Lu, D.D.C. Design of fuse–MOSFET pair for fault-tolerant DC/DC converters. IEEE Trans. Power Electron. 2016, 31, 6069–6074. [Google Scholar] [CrossRef]
Figure 1. Typical high-power spacecraft distributed power system with DC/DC converters.
Figure 1. Typical high-power spacecraft distributed power system with DC/DC converters.
Energies 16 00556 g001
Figure 2. Control scheme of the fault-tolerant strategy for flying capacitor DC/DC converter.
Figure 2. Control scheme of the fault-tolerant strategy for flying capacitor DC/DC converter.
Energies 16 00556 g002
Figure 3. The diagram of the key quantity under the situation in which short-circuit fault occurs in switch S3.
Figure 3. The diagram of the key quantity under the situation in which short-circuit fault occurs in switch S3.
Energies 16 00556 g003
Figure 4. Stages analysis when short-circuit fault occurs in S3 (VL < 0.5 VH).
Figure 4. Stages analysis when short-circuit fault occurs in S3 (VL < 0.5 VH).
Energies 16 00556 g004
Figure 5. Stages of the three-level mode when VL < 0.5 VH.
Figure 5. Stages of the three-level mode when VL < 0.5 VH.
Energies 16 00556 g005
Figure 6. Stages of capacitor voltage control mode after short-circuit fault occurs in S3.
Figure 6. Stages of capacitor voltage control mode after short-circuit fault occurs in S3.
Energies 16 00556 g006
Figure 7. The diagram of the key quantity under the situation in which short-circuit fault occurs in switch S4.
Figure 7. The diagram of the key quantity under the situation in which short-circuit fault occurs in switch S4.
Energies 16 00556 g007
Figure 8. Stage analysis (VL < 0.5 VH).
Figure 8. Stage analysis (VL < 0.5 VH).
Energies 16 00556 g008
Figure 9. Stages of S4 short-circuited.
Figure 9. Stages of S4 short-circuited.
Energies 16 00556 g009
Figure 10. Short-circuit fault analysis (VL > 0.5 VH). (a) The stages when S3 is short-circuited; (b) stage analysis.
Figure 10. Short-circuit fault analysis (VL > 0.5 VH). (a) The stages when S3 is short-circuited; (b) stage analysis.
Energies 16 00556 g010
Figure 11. The analysis of the stages under S3 fault. (a) Equivalent circuit; (b) the simulation curve (VL 80 V, VH 100 V, initial value of IL-10 A).
Figure 11. The analysis of the stages under S3 fault. (a) Equivalent circuit; (b) the simulation curve (VL 80 V, VH 100 V, initial value of IL-10 A).
Energies 16 00556 g011
Figure 12. Maximum current under different levels of inductance when S3 is short-circuited.
Figure 12. Maximum current under different levels of inductance when S3 is short-circuited.
Energies 16 00556 g012
Figure 13. Short-circuit fault analysis (VL > 0.5 VH). (a) The stages when S4 is short-circuited; (b) stage analysis.
Figure 13. Short-circuit fault analysis (VL > 0.5 VH). (a) The stages when S4 is short-circuited; (b) stage analysis.
Energies 16 00556 g013
Figure 14. The analysis of the stages under S4 fault. (a) Equivalent circuit; (b) the simulation curve (VL 80 V, VH 100 V, initial value of IL 10 A).
Figure 14. The analysis of the stages under S4 fault. (a) Equivalent circuit; (b) the simulation curve (VL 80 V, VH 100 V, initial value of IL 10 A).
Energies 16 00556 g014
Figure 15. Maximum current under different levels of inductance when S4 is short-circuited.
Figure 15. Maximum current under different levels of inductance when S4 is short-circuited.
Energies 16 00556 g015
Figure 16. The waveforms of S4 short-circuit fault (VL < 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Figure 16. The waveforms of S4 short-circuit fault (VL < 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Energies 16 00556 g016
Figure 17. The waveforms of S3 short-circuit fault (VL < 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Figure 17. The waveforms of S3 short-circuit fault (VL < 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Energies 16 00556 g017
Figure 18. The waveforms of S3 short-circuit fault (VL > 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Figure 18. The waveforms of S3 short-circuit fault (VL > 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Energies 16 00556 g018
Figure 19. The waveforms of S4 short-circuit fault (VL > 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Figure 19. The waveforms of S4 short-circuit fault (VL > 0.5 VH). (a) Light load 100 W; (b) heavy load 1000 W.
Energies 16 00556 g019
Figure 20. The experimental waveforms of S3 short-circuit fault. (a) Overall stages; (b) the waveform of three-level mode before S3 fault; (c) the waveform of S3 short-circuit fault during fault; (d) the waveform of two-level mode after S3 fault.
Figure 20. The experimental waveforms of S3 short-circuit fault. (a) Overall stages; (b) the waveform of three-level mode before S3 fault; (c) the waveform of S3 short-circuit fault during fault; (d) the waveform of two-level mode after S3 fault.
Energies 16 00556 g020
Figure 21. The experimental waveforms of S4 short-circuit fault. (a) Overall stages; (b) the waveform of three-level mode before S4 fault; (c) the waveform of S4 short-circuit fault during fault; (d) the waveform of two-level mode after S4 fault.
Figure 21. The experimental waveforms of S4 short-circuit fault. (a) Overall stages; (b) the waveform of three-level mode before S4 fault; (c) the waveform of S4 short-circuit fault during fault; (d) the waveform of two-level mode after S4 fault.
Energies 16 00556 g021aEnergies 16 00556 g021b
Table 1. The parameters of the different simulation cases.
Table 1. The parameters of the different simulation cases.
ItemCase I (Figure 16) ValueCase II (Figure 17) ValueCase III (Figure 18) ValueCase IV (Figure 19) Value
Input voltage30 V30 V80 V80 V
Output DC bus voltage100 V100 V100 V100 V
Input inductor1 mH1 mH1 mH1 mH
Flying capacitor200 μF200 μF200 μF200 μF
Output bus capacitor1 mF1 mF1 mF1 mF
Load power100 W/1000 W100 W/1000 W100 W/1000 W100 W/1000 W
Fault locationInner switch S3Outer switch S4Inner switch S3Outer switch S4
Table 2. The parameters of the prototype of flying capacitor DC/DC converter.
Table 2. The parameters of the prototype of flying capacitor DC/DC converter.
ItemValue
Input voltage10 V
Output DC bus voltage32 V
Input inductor100 μH
Flying capacitor20 μF
Output bus capacitor470 μF
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Li, H.; Gu, Y.; Zhang, X.; Liu, Z.; Zhang, L.; Zeng, Y. A Fault-Tolerant Strategy for Three-Level Flying-Capacitor DC/DC Converter in Spacecraft Power System. Energies 2023, 16, 556. https://doi.org/10.3390/en16010556

AMA Style

Li H, Gu Y, Zhang X, Liu Z, Zhang L, Zeng Y. A Fault-Tolerant Strategy for Three-Level Flying-Capacitor DC/DC Converter in Spacecraft Power System. Energies. 2023; 16(1):556. https://doi.org/10.3390/en16010556

Chicago/Turabian Style

Li, Haijin, Yu Gu, Xiaofeng Zhang, Zhigang Liu, Longlong Zhang, and Yi Zeng. 2023. "A Fault-Tolerant Strategy for Three-Level Flying-Capacitor DC/DC Converter in Spacecraft Power System" Energies 16, no. 1: 556. https://doi.org/10.3390/en16010556

APA Style

Li, H., Gu, Y., Zhang, X., Liu, Z., Zhang, L., & Zeng, Y. (2023). A Fault-Tolerant Strategy for Three-Level Flying-Capacitor DC/DC Converter in Spacecraft Power System. Energies, 16(1), 556. https://doi.org/10.3390/en16010556

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop