A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking
Abstract
:1. Introduction
2. The Skin-Electrode Interface of Textile Electrode
3. Electrode Material
3.1. Experimental Method
3.2. Results and Discussion
4. Electrode Size
4.1. Experimental Method
4.2. Results and Discussion
5. Motion Sensor FPCB
6. Fabrication of the Hybrid Textile Electrode
7. Hardware Setup
8. The Implementation of the Hybrid Textile Electrode for ECG Monitoring and Motion Tracking
9. Conclusions
Author Contributions
Funding
Conflicts of Interest
References
- Scilingo, E.P.; Gemignani, A.; Paradiso, R.; Taccini, N.; Ghelarducci, B.; De Rossi, D. Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. IEEE Trans. Inf. Technol. Biomed. 2005, 9, 345–352. [Google Scholar] [CrossRef] [PubMed]
- Mestrovic, M.A.; Helmer, R.J.; Kyratzis, L.; Kumar, D. Preliminary study of dry knitted fabric electrodes for physiological monitoring. In Proceedings of the Intelligent Sensors, Sensor Networks and Information 3rd International Conference, Melbourne, Australia, 3–6 December 2007; pp. 601–606. [Google Scholar]
- Paradiso, R.; Loriga, G.; Taccini, N. A wearable health care system based on knitted integrated sensors. IEEE Trans. Inf. Technol. Biomed. 2005, 9, 337–344. [Google Scholar] [CrossRef] [PubMed]
- Priniotakis, G.; Westbroek, P.; Van Langenhove, L.; Hertleer, C. Electrochemical impedance spectroscopy as an objective method for characterization of textile electrodes. Trans. Inst. Meas. Control 2007, 29, 271–281. [Google Scholar] [CrossRef]
- Pola, T.; Vanhala, J. Textile electrodes in ECG measurement. In Proceedings of the Intelligent Sensors, Sensor Networks and Information 3rd International Conference, Melbourne, Australia, 3–6 December 2007; pp. 635–639. [Google Scholar]
- Beckmann, L.; Kim, S.; Dueckers, H.; Luckhardt, R.; Zimmermann, N.; Gries, T.; Leonhardt, S. Characterization of textile electrodes for bioimpedance spectroscopy. In Proceedings of the Ambience: International Scientific Conference Smart Textile—Technology and Design, Boras, Sweden, 19–20 September 2008; pp. 79–83. [Google Scholar]
- Paradiso, R.; Loriga, G.; Taccini, N.; Gemignani, A.; Ghelarducci, B. WEALTHY-a wearable healthcare system: New frontier on e-textile. J. Telecommun. Inf. Technol. 2005, 105–113. [Google Scholar]
- Catrysse, M.; Puers, R.; Hertleer, C.; Van Langenhove, L.; Van Egmond, H.; Matthys, D. Towards the integration of textile sensors in a wireless monitoring suit. Sensor Actuat. A-Phys. 2004, 114, 302–311. [Google Scholar] [CrossRef]
- Marozas, V.; Petrenas, A.; Daukantas, S.; Lukosevicius, A. A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings. J. Electrocardiol. 2011, 44, 189–194. [Google Scholar] [CrossRef] [PubMed]
- Ankhili, A.; Tao, X.; Cochrane, C.; Coulon, D.; Koncar, V. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring. Materials 2018, 11, 256. [Google Scholar] [CrossRef] [PubMed]
- Rattfält, L.; Lindén, M.; Hult, P.; Berglin, L.; Ask, P. Electrical characteristics of conductive yarns and textile electrodes for medical applications. Med. Biol. Eng. Comput. 2007, 45, 1251–1257. [Google Scholar] [CrossRef] [PubMed]
- Martinsen, O.G.; Grimnes, S. Bioimpedance and Bioelectricity Basics; Academic Press: Cambridge, MA, USA, 2011. [Google Scholar]
- Jang, S.; Cho, J.; Jeong, K.; Cho, G. Exploring Possibilities of ECG Electrodes for Bio-monitoring Smartwear with Cu Sputtered Fabrics. In Human-Computer Interaction. Interaction Platforms and Techniques. HCI 2007; Lecture Notes in Computer Science; Jacko, J.A., Ed.; Springer: Berlin/Heidelberg, Germany, 2007; Volume 4551. [Google Scholar]
- Pani, D.; Dessì, A.; Saenz-Cogollo, J.F.; Barabino, G.; Fraboni, B.; Bonfiglio, A. Fully textile, PEDOT: PSS based electrodes for wearable ECG monitoring systems. IEEE Trans. Biomed. Eng. 2016, 63, 540–549. [Google Scholar] [CrossRef] [PubMed]
- Paradiso, R. Wearable health care system for vital signs monitoring. In Proceedings of the Information Technology Applications in Biomedicine, Birmingham, UK, 2003; pp. 283–286. [Google Scholar]
- Carvalho, H.; Catarino, A.P.; Rocha, A.M.; Postolache, O. Health monitoring using textile sensors and electrodes: An overview and integration of technologies. In Proceedings of the International Symposium on Medical Measurements and Applications, Lisbon, Portugal, 2014; pp. 70–75. [Google Scholar]
- Castiglioni, P.; Faini, A.; Parati, G.; Di Rienzo, M. Wearable Seismocardiography. In Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, France, 22–26 August 2007; pp. 3954–3957. [Google Scholar]
- Jourand, P.; De Clercq, H.; Corthout, R.; Puers, R. Textile integrated breathing and ECG monitoring system. Procedia Chem. 2009, 1, 722–725. [Google Scholar] [CrossRef]
- Di Rienzo, M.; Rizzo, F.; Parati, G.; Brambilla, G.; Ferratini, M.; Castiglioni, P. MagIC system: A new textile-based wearable device for biological signal monitoring. Applicability in daily life and clinical setting. In Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, Shanghai, China, 17–18 January 2005; pp. 7167–7169. [Google Scholar]
- Bifulco, P.; Cesarelli, M.; Fratini, A.; Ruffo, M.; Pasquariello, G.; Gargiulo, G. A wearable device for recording of biopotentials and body movements. In Proceedings of the Medical Measurements and Applications Proceedings, Bari, Italy, 30–31 May 2011; pp. 469–472. [Google Scholar]
- Mittleman, M.A.; Maclure, M.; Tofler, G.H.; Sherwood, J.B.; Goldberg, R.J.; Muller, J.E. Triggering of acute myocardial infarction by heavy physical exertion--protection against triggering by regular exertion. New Engl. J. Med. 1993, 329, 1677–1683. [Google Scholar] [CrossRef] [PubMed]
- Hansson, A.; Madsen-Härdig, B.; Olsson, S.B. Arrhythmia-provoking factors and symptoms at the onset of paroxysmal atrial fibrillation: A study based on interviews with 100 patients seeking hospital assistance. BMC Cardiovasc. Disor. 2004, 4, 13. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Lampert, R.; Joska, T.; Burg, M.M.; Batsford, W.P.; McPherson, C.A.; Jain, D. Emotional and physical precipitants of ventricular arrhythmia. Circulation 2002, 106, 1800–1805. [Google Scholar] [CrossRef] [PubMed]
- Kohl, H.W., III; Powell, K.E.; Gordon, N.F.; Blair, S.N.; Paffenbarger, R.S., Jr. Physical activity, physical fitness, and sudden cardiac death. Epidemiol. Rev. 1992, 14, 37–58. [Google Scholar] [CrossRef] [PubMed]
- Benarroch, E.E. Postural tachycardia syndrome: A heterogeneous and multifactorial disorder. Mayo Clin. Proc. 2012, 87, 1214–1225. [Google Scholar] [CrossRef] [PubMed]
- Cobb, L.A.; Weaver, W.D. Exercise: A risk for sudden death in patients with coronary heart disease. J. Am. Coll. Cardiol. 1986, 7, 215–219. [Google Scholar] [CrossRef]
- Burke, A.P.; Farb, A.; Malcom, G.T.; Liang, Y.H.; Smialek, J.E.; Virmani, R. Plaque rupture and sudden death related to exertion in men with coronary artery disease. J. Am. Med. Assoc. 1999, 281, 921–926. [Google Scholar] [CrossRef]
- Siscovick, D.S.; Weiss, N.S.; Fletcher, R.H.; Lasky, T. The incidence of primary cardiac arrest during vigorous exercise. N. Engl. J. Med. 1984, 311, 874–877. [Google Scholar] [CrossRef] [PubMed]
- Webster, J.G. Medical Instrumentation-Application and Design; John Wiley & Sons: Hoboken, NJ, USA, 2009. [Google Scholar]
- Geddes, L.A.; Valentinuzzi, M.E. Temporal changes in electrode impedance while recording the electrocardiogram with ‘dry’ electrodes. Ann. Biomed. Eng. 1973, 1, 356–367. [Google Scholar] [CrossRef] [PubMed]
- Olson, W.; Schmincke, D.; Henley, B. Time and frequency dependence of disposable ECG electrode-skin impedance. Med. Instrum. 1978, 13, 269–272. [Google Scholar]
- Tiller, J.C.; Liao, C.J.; Lewis, K.; Klibanov, A.M. Designing surfaces that kill bacteria on contact. Proc. Natl. Acad. Sci. USA 2001, 98, 5981–5985. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Lansdown, A.B. A pharmacological and toxicological profile of silver as an antimicrobial agent in medical devices. Adv. Pharmacol. Sci. 2010. [Google Scholar] [CrossRef] [PubMed]
- Lee, H.J.; Jeong, S.H. Bacteriostasis and skin innoxiousness of nanosize silver colloids on textile fabrics. Text. Res. J. 2005, 75, 551–556. [Google Scholar] [CrossRef]
- Samberg, M.E.; Oldenburg, S.J.; Monteiro-Riviere, N.A. Evaluation of silver nanoparticle toxicity in skin in vivo and keratinocytes in vitro. Environ. Health Perspect. 2009, 118, 407–413. [Google Scholar] [CrossRef] [PubMed]
- Tregear, R.T. Physical Functions of Skin; Elsevier: New York, NY, USA, 1966; Volume 5. [Google Scholar]
- Priniotakis, G.; Westbroek, P.; Van Langenhove, L.; Kiekens, P. An experimental simulation of human body behaviour during sweat production measured at textile electrodes. Int. J. Cloth. Sci. Technol. 2005, 17, 232–241. [Google Scholar] [CrossRef]
- Westbroek, P.; Priniotakis, G.; Palovuori, E.; De Clerck, K.; Van Langenhove, L.; Kiekens, P. Quality control of textile electrodes by electrochemical impedance spectroscopy. Text. Res. J. 2006, 76, 152–159. [Google Scholar] [CrossRef]
- Xu, P.J.; Zhang, H.; Tao, X.M. Textile-structured electrodes for electrocardiogram. Text. Prog. 2008, 40, 183–213. [Google Scholar] [CrossRef]
- Liu, H.; Tao, X.; Xu, P.; Zhang, H.; Bai, Z. A dynamic measurement system for evaluating dry bio-potential surface electrodes. Measurement 2013, 46, 1904–1913. [Google Scholar] [CrossRef]
- Hearle, J.W.; Grosberg, P.; Backer, S. Structural Mechanics of Fibers, Yarns and Fabrics; Wiley Interscience: Hoboken, NJ, USA, 1969; Volume I. [Google Scholar]
- Peirce, F.T. Geometrical principles applicable to the design of functional fabrics. Text. Res. J. 1947, 17, 123–147. [Google Scholar] [CrossRef]
- Peirce, F.T. 5—The geometry of cloth structure. J. Text. Inst. Trans. 1937, 28, T45–T96. [Google Scholar] [CrossRef]
- Xiang, A.; Orathai, T.; George, K.S. Investigating the Performance of Dry Textile Electrode for wearable End-Uses. J. Text. Inst 2018, in press. [Google Scholar]
- Puurtinen, M.M.; Komulainen, S.M.; Kauppinen, P.K.; Malmivuo, J.A.; Hyttinen, J.A. Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel. In Proceedings of the Engineering in Medicine and Biology Society, New York, NY, USA, 30 August–3 September 2006; pp. 6012–6015. [Google Scholar]
Electrode Materials | Components | Structure | Fabric Thickness (mm) | Yarn Diameter (mm) | Wales/cm | Courses/cm | |
---|---|---|---|---|---|---|---|
TE1 | 78% silver plated nylon 66 + 22% Elastomer | Weft knitted | 0.45 ± 10% | 0.13 ± 20% | 28/cm | 30/cm | |
TE2 | 100% silver plated nylon 66 | Weft knitted | 1.25 ± 10% | 0.60 ± 20% | 5/cm | 6/cm | |
TE3 | 100% silver plated nylon 66 | Weft knitted | 0.70 ± 10% | 0.30 ± 20% | 8/cm | 12/cm | |
TE4 | 94% silver plated nylon 66 + 6% elastomer | Weft knitted 3D spacer | 2.50 ± 10% | 0.18 ± 20% | 17/cm (surface) | 28/cm (surface) |
Large Textile Electrode | Medium Textile Electrode | Small Textile Electrode | Conventional Wet Electrode | |
---|---|---|---|---|
Shape of Electrodes | ||||
Electrode Area (cm2) | 8 | 4.5 | 2.25 | 2.27 |
Electrode Dimension | 2 × 4 (w × L, cm) | 1.5 × 3.0 (w × L, cm) | 1.5 × 1.5 (w × L, cm) | 1.7 (φ, cm) |
© 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
An, X.; Stylios, G.K. A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking. Materials 2018, 11, 1887. https://doi.org/10.3390/ma11101887
An X, Stylios GK. A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking. Materials. 2018; 11(10):1887. https://doi.org/10.3390/ma11101887
Chicago/Turabian StyleAn, Xiang, and George K. Stylios. 2018. "A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking" Materials 11, no. 10: 1887. https://doi.org/10.3390/ma11101887
APA StyleAn, X., & Stylios, G. K. (2018). A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking. Materials, 11(10), 1887. https://doi.org/10.3390/ma11101887