Article

Material Analysis of Steel Fibre Reinforced High-Strength Concrete in Terms of Flexural Behaviour. Experimental and Numerical Investigation

by
Czesław Bywalski
*,
Maciej Kaźmierowski
,
Mieczysław Kamiński
and
Michał Drzazga
Faculty of Civil Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
*
Author to whom correspondence should be addressed.
Materials 2020, 13(7), 1631; https://doi.org/10.3390/ma13071631
Submission received: 13 February 2020 / Revised: 26 March 2020 / Accepted: 30 March 2020 / Published: 1 April 2020
(This article belongs to the Special Issue Testing of Materials and Elements in Civil Engineering)

Abstract

:
The paper presents the results of tests for flexural tensile strength (fct,fl) and fracture energy (Gf) in a three-point bending test of prismatic beams with notches, which were made of steel fibre reinforced high-strength concrete (SFRHSC). The registration of the conventional force–displacement (F–δ) relationship and unconventional force-crack tip opening displacement (CTOD) relationship was made. On the basis of the obtained test results, estimations of parameters fct,fl and Gf in the function of fibre reinforcement ratio were carried out. The obtained results were applied to building and validating a numerical model with the use of the finite element method (FEM). A non-linear concrete damaged plasticity model CDP was used for the description of the concrete. The obtained FEM results were compared with the experimental ones that were based on the assumed criteria. The usefulness of the flexural tensile strength and fracture energy parameters for defining the linear form of weakening of the SFRHSC material under tension, was confirmed. Own equations for estimating the flexural tensile strength and fracture energy of SFRHSC, as well as for approximating deflections (δ) of SFRHSC beams as the function of crack tip opening displacement (CTOD) instead of crack mouth opening displacement (CMOD), were proposed.

1. Introduction

Steel fibre reinforced high-strength concrete (SFRHSC), in comparison with plain high-strength concrete, is marked by a more quasi-plastic character and increased resistance to cracking on bending [1,2]. The following should be considered to be the most important parameters of dispersed reinforcement structure, which can inhibit cracking in the cement matrix: volume of fibres in the composite (Vf) [3], slenderness of fibres (λ) [4,5], fibre material characteristics, spatial distribution of fibres in concrete [6], as well as adhesion of fibres to cement matrix, resulting from mechanical anchorage, adhesion, and friction [7]. The addition of steel fibres to concrete might improve some of its mechanical parameters, including compressive strength (fc) [8,9] and the modulus of elasticity (Ec) [3,8,10]. The use of steel fibres in concrete also significantly increases its flexural tensile strength (fct,fl) [3,4,9,11]. This improvement is insignificant in the range of proportional strains and clear after they are exceeded, both before reaching the breaking load value and after exceeding it. Knowing the mechanical response of the structure under loading conditions is crucial for the SFRHSC beams in bending.
The behaviour of steel fibre reinforced concrete (SFRC) or SFRHSC beam in three-point bending test can be presented while using Tlemat’s proposal [7], which assumes a four-phase scope of work. Figure 1 shows the cross section of SFRC or SFRHSC beam before failure. Particular phases, depending on the load level, differ in the idealized distribution of stress blocks that result from the development of cracks in the fracture process zone (FPZ). The individual steps can be described, as follows: Phase 1—linear-elastic relationship between force (F) and deflection, no cracking in the zone of tensile stresses (zone Z1), slight influence of the slenderness of fibres (λ) on the value of the transferred load (F), maximum value of tensile stress being dependent on the concrete and volume of fibres in the composite (Vf) [12]; Phase 2—the initiation of the micro-cracking process (0.1–0.2 mm), forces that result from the load are taken over by dispersed reinforcement in the zone Z2, the beginning of stress reduction in the FPZ, slight development of the fibre-pulling out process after crossing the limit load, change of the linear-elastic force–deflection relationship into the elastic-plastic relationship; Phase 3—further propagation of the cracking, development of fibre-pulling out process (zone Z3), continuation of force transmission by the fibres (zone Z2), raising the position of the neutral axis (NA); and, Phase 4—negligible transmission of forces by fibres (most of the fibres pull out from the cement matrix, zone Z4), no tensile stresses in the zone Z4, further possibility of load transfer provided by fibres in the zones Z2 and Z3 until the cracking reaches the neutral axis (NA).
Despite numerous studies, the method of testing and assessment of SFRHSC properties after cracking is still under discussion [11,13]. Technical committees propose various methods for determining the fracture energy and residual stresses. The lack of full standardization hinders the design and full use of this type of material in the construction industry. Therefore, there is a well-founded need for research in this direction. Differentiation applies to: loading method (three- or four-point bending test), shape and geometry of the researched element (beams, circular plates, cubes, etc.), or measured values (deflections, CMOD, CTOD).
The fracture resistance of SFRHSC is determined on the basis of standardized experimental tests [14]. According to [15], force–deflection (F–δ) or force-crack mouth opening displacement (F–CMOD) relationship in a three-point bending test are recorded. F–CMOD relationship analysis is widely used. It is performed by means of a clip gauge extensometer or a linear variable differential transformer (LVDT) [15]. The Italian National Research Council [16] recommends assessing the properties after cracking of steel fibre reinforced concrete based on the F–CTOD relationship. The analysis of the F–CTOD relationship is more experimentally difficult to perform as compared to F–CMOD. However, registering the force-width relationship of a crack opening is valuable from the point of view of conducting numerical analyses and cracking energy. Namely, it enables the direct comparison of experimental and numerical results and definition of a numerical material model (e.g., determination of the allowable crack width with tension in the concrete damaged plasticity model). In turn, Bencardino [14] showed that an assessment of fracture resistance could be carried out on the basis of force-crack tip opening displacement relationship (F–CTOD). Bencardino recorded F–CTOD and F–CMOD relationships for HSC and SFRHSC beams at the same time. Almost identical shape and size of F–CTOD and for F–CMOD curves could be observed. However, research of Bencardino must be continued to generalize the conclusions. Taking the above into account, the results of tests of F–CTOD relationship are also presented in the paper. In this way, the database of literature related to F–CTOD relationships has been extended. It also allowed for proposing equations for the approximation of SFRHSC beams deflections in CTOD function instead of CMOD [15].
The purpose of the article is to assess the flexural tensile strength (fct,fl) and fracture energy (Gf) of high-performance concrete with the addition of steel fibres (SFRHSC). The above parameters are essential when designing SFRHSC structural elements. The fracture energy of the SFRHSC composites is determined on the basis of standardized experimental tests [15]. The F–δ or F–CMOD relationships for three-point bending beams are recorded. Experimental tests were carried out in accordance with standard [15], and extended by registering the F–CTOD relationships, in order to achieve the above objectives. Additionally, the estimation of fct,fl and Gf quantities as a function of fibre reinforcement degree was made, and equations were developed, which contribute to the extension of standard records [15]; the standard currently allow an approximation of deflections of steel fibre reinforced concrete beams only as a function of CMOD. The obtained experimental results of the beams were compared with the numerical results (finite element method (FEM)) in quantitative and qualitative terms in order to assess the usefulness of the parameters of flexural tensile strength (fct,fl) and fracture energy (Gf), while also defining the linear form of weakening of the SFRHSC material under tension. The knowledge of the mechanical response of the structure under load is essential from the designer’s point of view concerning bending beams.

2. Experimental Research

2.1. Materials and Methods

The scope of research included making three series of composites (A, B, and C), which were differentiated by the content of steel fibres. Series A (control) did not contain any fibres; Series B contained 1.0% steel fibres (78 kg/m3); and, Series C included 1.5% steel fibres (118 kg/m3). The scope of tests and sample specifications are presented in Table 1. The samples used for strength tests were cured and protected according to [17].
The concrete mix was designed for the strength class C55/67 [18]. The following components were used in order to produce the concrete mixture: portland cement CEM-I 52.5N, natural washed aggregate with a fraction of 0–2 mm, broken granite aggregate with fractions 2–8 mm and 8–16 mm, polymer superplasticizer (Sika ViscoCrete 5-600 for high-performance concrete; properties: strong liquefaction (class S4/S5), no chlorides, increased early, and final strength of concrete mix, density 1.07 kg/dm3, PH 4.4 ± 1,0), and fly ash from hard coal (specific surface—3610 cm2/g; penetrability for the sieve with mesh 0.045 mm—38.50% [19]; mineralogical composition: SO3—0.38%, CaO—2.44%, SiO2—51.72%, Al2O3—25.15%, and Fe2O3—5.21%). The water-cement ratio of the mixture was 0.3 (w/c = 0.3). Straight steel fibres with a length of 20 mm (l) and a diameter of 0.3 mm (d) were added to the concrete samples, series B and C. The tensile strength of the fibres was 2000 MPa, while the Young’s modulus was 200 GPa. In order to obtain uniform consistency of concrete mix for all series, while maintaining a constant value of the w/c coefficient, test samples were prepared on the basis of which the optimal superplasticizer content was determined in individual composite series (A, B, and C). The consistency test was carried out using the drop cone method [20]. The indicator of the degree of mix liquidity ranged from 155 to 165 mm (consistency class S3/S4 [20]). Table 2 presents the composition of the concrete mix for individual series. All the components of the mixture were dosed by weight with an accuracy of 1% (without steel fibres and superplasticizer). The volume of each series of concrete mix was 453.2 dm3 (in accordance with the assumed programme of research with a wider scope). The order of dispensing the ingredients was as follows: the aggregate was mixed first, and then cement and fly ash were added. After thorough mixing, water was added, followed by a superplasticizer. Steel fibres were the last ingredient added to the mix. The total mixing time was 490 s. The concrete preparation equipment included: mixers to make trial batches, electronic scales for dosing the components of the concrete mix with an accuracy of 5 g and 0.1 g, a plate mixer (concrete plant), containers for transporting concrete, and a vibration table for compacting the concrete mix. The steel fibres and superplasticizer were dosed by weight with an accuracy of 0.1 g. Other components of the mixture were dosed with an accuracy of 5 g.
Experimental studies were carried out to determine the flexural tensile strength of HSC and SFRHSC, as well as their proportionality limit (fct,fl,L) and the behaviour of beams in conditions of the exceeded critical limit load. This is why parallel relationships: force–deflection (F–δ) and force-crack tip opening displacement (F–CTOD) were observed. Characteristics of the tested composites, compressive strength (fc), and modulus of elasticity (Ec) tests were carried out, owing to the need to obtain more accurate material. The obtained results were used for numerical analyses of HSC and SFRHSC beams.
The testing of the flexural tensile strength was carried out in accordance with [15]. During the study, parallel relationships: force–deflection (F–δ) and force-crack tip opening displacement (F–CTOD) were recorded. The adopted research program aimed, among others, at comparing these relationships.
Flexural tensile strength (fct,fl) and the corresponding limit of proportionality (fct,fl,L) were determined according to dependence (1), taking, for calculations, the limit load (Fmax) and the load corresponding to deflection (F0.05) respectively [15]. Figure 2 shows the test setup project. Figure 3a shows the beam prepared for testing, and Figure 3b depicts the detailed arrangement of the sensors for the measurement of top notch opening (CTOD) and deflection (δ).
σ c t , f l = 3 F i l 2 b h s p 2 ,
where:
  • l—beam span;
  • b—beam width; and,
  • hsp—beam height less notch height.
Measurement data CTOD and δ were recorded by means of extensometers with a range of 10 mm and accuracy of 0.001 mm, which were placed symmetrically along the longitudinal axis of the beam. The testing of beams was carried out at the ZD100 strength testing station (VEB Werkstoffprufmaschinen, Leipzig, Germany) with the computerized recording of synchronized results (time, F and δ). The frequency of records was 10 Hz.
Crack tip opening displacement (CTOD) means the width of a crack at the top of the technological notch. Figure 2 and Figure 3 indicate the location of the crack opening measurement (sensor No. 1). The height of the technological notch is 25 ± 1 mm, while the width is 4.98 mm (<5 mm). These values were adopted in accordance with the standard for testing fibre reinforced concrete [15]. The cuts were made while using a power saw with a guide, after prior marking. The dimensions of the technological notch were controlled with an electronic caliper.
The compressive strength tests (fc) were carried out in accordance with the standard [21] and the modulus of elasticity was measured according [22].
All of the tests were carried out after 28 days from preparing the composites.

2.2. Experimental Results and Discussion

2.2.1. Results of Tests for Mechanical Features

The results of flexural tensile strength tests (fct,fl), limit of proportionality (fct,fl,L), compressive strength (fc) and the modulus of elasticity (Ec) with the arithmetic mean of results x, and standard deviation for each series (s) are presented in Table 3.
The average density of composites (ρ) in each series was: A—2389 kg/m3, B—2493 kg/m3, and C—2522 kg/m3.
When analysing the results that are contained in Table 3, it can be seen that, with an increasing volume of steel fibres (Vf) in the composite, the flexural tensile strength (fct,fl) also significantly increases. For B series beams, the average increase in the value fct,fl when compared to that obtained for series A beams (control series) was 95.0%, and for C series beams 132.1%. It should be noted that the results of flexural tensile strength (fct,fl) of SFRHSC beams can be burdened with a large spread of results (V = 20–30%) [23,24]. This might be due to, among other factors, the effect of the scale (different surfaces of the beams’ breakthrough) or the efficiency of anchoring the fibres in the cement matrix. The average value of stresses defining the conventional limit of proportionality of bending beams was for series B—6.14 MPa and for series C—7.01 MPa, while the coefficient of variation was 11.4% and 7.3%, respectively.
Figure 4 presents the results of flexural tensile strength (fct,fl), depending on the fibre reinforcement ratio (Vfl/d) and a linear regression Equation (2) with the determination coefficient of R2 = 86%, which is a measure of the quality of model fit. The root from the variance of regression equation estimators was 1.15 for the directional coefficient and 0.80 for the free expression, respectively. It should be noted that a large confidence interval of the directional regression coefficient was obtained (2.72), owing to the small size of the sample (nine results). On the basis of the statistical test carried out (Student’s t-distribution), for the assumed level of significance α = 5%, the obtained regression coefficient of the model is statistically significant (p < α, where p is the probability of accepting the null hypothesis of the parameter).
f c t , f l = f ct , fl + 7.54 V f l d ,
where: f c t , f l —the flexural tensile strength of HSC.
As part of the analysis of the model’s fit to the empirical data, the authors also considered various parametric models with two explanatory variables in the form of compressive strength (fc) and fibre reinforcement (Vfl/d), which are available in the literature on the subject [3,4,25,26]. Consequently, a non-linear regression Equation (3) with a coefficient R2 = 86.4% was obtained. The results of flexural tensile strength (fct,fl), depending on the compressive strength (fc) and fibre reinforcement ratio (Vfl/d), as well as a graphical presentation of the Equation (3) are shown in Figure 5. It should be noted that the regression equation applies to the range of variables under consideration (compressive strength 76–96 MPa; slenderness of fibres 66.7; and, fibre content by volume 0; 1.0; 1.5%).
f c t , f l = 0.66 f c + 6.88 V f l d
The roots of the compressive strength estimate and the fibre reinforcement ratio of model (3) were 0.09 and 1.21, respectively. Statistically significant structural parameters of the model (p < α) were obtained on the basis of the Student’s t-test, for the assumed level of significance α = 5%.
Volumetric addition of steel fibres (Vf) in series B (1.0%) and C (1.5%) resulted in an increase in the compression strength (fc) in relation to series A (control) by 12.9% and 24.3%, respectively. The obtained increase in compressive strength (fc) of SFRHSC concretes is confirmed in the scientific literature on the subject [3,4,27], which reports, for the addition of fibres (Vf) in the range of 0–1.5%, an increase in compressive strength in the case of SFRHSC from 10% to 20%, as compared with HSC.
The presence of steel fibres in the composite also increased the value of the modulus of elasticity (Ec). For the B and C series, the increase in the modulus of elasticity in relation to the reference series (series A) was 15.0% and 17.0%, respectively. It was observed that the increase in fibre content from 1.0% to 1.5% (Vf) in the composite (C series results) resulted in only a slight increase in the modulus of elasticity (by 2.0%). A similar increase in the modulus of elasticity (Ec) of SFRHSC in relation to HSC can be found in [8,28,29]. The increase ranges from 7.0% to 27.0%, for the addition of steel fibres in the range of 0–1.5% in the composite. It should be noted that, along with the increase in the content of steel fibres in the composite (Vf), the compressive strength (fc) [10,30] and modulus of elasticity (Ec) [31,32] are not always significantly increased.

2.2.2. F–δ and F–CTOD Relationship

Figure 6 shows the relationships of force–deflection (F–δ), in particular SFRHSC beams, and in Figure 7 the same relationship can be seen for HSC beams. The deflection values (δ) were the arithmetic mean of the sensor readings (Nos. 2–5, according to Figure 2). The force–deflection relationships that were obtained on the basis of the results of the arithmetic mean of beams in particular series (A, B and C) are shown in Figure 7 and Figure 8 (Figure 7—due to the smaller range of HSC beams deformation in relation to SFRHSC beams). The second type of relationship, namely force-crack tip opening displacement (F–CTOD), which was measured during the HSC and SFRHSC beam tests, is shown in Figure 9 and Figure 10, respectively. The values of individual beams CTOD placed on the graph are the mean of the sensors nos. 1 and 6 (see Figure 2). The F–CTOD relationships that were obtained on the basis of the arithmetic mean of the results in particular series are shown in Figure 11 (series A, B, and C) and Figure 10 (series A only).
When analysing Figure 6 and Figure 9, one can observe minimal differences in the shape and size of curves describing F–δ and F–CTOD relationships (curves overlap). Figure 12 presents deflections of the B series beams, depending on the crack tip opening displacement (CTOD) and the δ–CTOD relationship obtained on the basis of the arithmetic mean of the series results. Analogous results are presented in Figure 13 for C-series beams. The δ–CTOD relationships that were obtained on the basis of the arithmetic mean of series B and C results can be approximated by linear Equations (4) and (5) (R2 = 99%), respectively. These equations could be a contribution to the extension of the standard records [15], which presently allow for an approximation of deflections (δ) of beams that were modified with steel fibres only as a function of crack mouth opening displacement (CMOD).
δ = 1.03 C T O D + a ,
where: a—constant term; a = 0.02, if CTOD > 0; a = 0, if CTOD = 0.
δ = 0.99 C T O D + b ,
where: b—constant term; b = 0.05, if CTOD > 0; b = 0, if CTOD = 0.
It should be noted that the regression Equations (4) and (5) were determined for specific laboratory and material conditions of the composite. In addition, they relate to the considered range of variables, and they should be verified in the future on a larger number of research results.
Figure 14 shows the damaged HSC and SFRHSC beams (owing to a similar failure mode of beams, only C series is presented). The presence of fibres affects the destruction characteristics of SFRHSC beams, which do not suddenly divide in contrast to HSC ones. After they are “destroyed”, SFRHSC beams are able to carry a set load (usually smaller than the breaking load) until the broken parts are “separated”.

2.2.3. Fracture energy of HSC and SFRHSC

The fracture energy, which is marked by the range of post-critical stress–elongation of concrete dependence (σ–w), can be treated according to Hilleborg’s proposal and the RILEM technical committee [33,34], as the material constant of the composite (other methods for calculating fracture energy are also applicable [35]). It determines the amount of energy that is required to produce a crack with a unit area that can be calculated while using the Equation (6).
G f = 1 b h s p 0 δ u F δ d δ + m 1 α 2 g δ u ,
where: m—beam mass; g—gravitational acceleration; δu—maximum deflection recorded during the test; α = 1 − L/2l; L—beam length; b, hsp, l—explanations identical to Equation (1).
Table 4 shows the results of the fracture energy for particular beams, along with the arithmetic mean (x) and the standard deviation (s) for each series. Figure 15 shows the influence of fibre reinforcement ratio (Vfl/d) upon the value of beam fracture energy (Gf) and the polynomial regression Equation (7) with the coefficient R2 = 96% (p < α). The roots from the estimators’ variance of the polynomial regression model (7) were, respectively: 3.15; 3.21; and, 0.57. On the basis of the Student’s t-test, for the assumed level of significance α = 5%, the obtained regression coefficients for the model are statistically significant (p < α).
G f = 10.72 ( V f l d ) 2 + 19.68 V f l d + 0.04 .
It should be noted that regression Equation (7) was determined for specific material conditions of the composite, and it applies to the considered range of variables (Vf, l, d and type of fibre). It should be remembered that the length, diameter, type, and volume of fibre strongly influence the fracture energy.

3. Numerical Analysis of Beams

3.1. Assumptions for the Numerical Model and Geometrical Model

Numerical analyses of SFRHSC beams were performed to assess the usefulness of the flexural tensile strength and fracture energy parameters for defining the linear form of weakening of the SFRHSC material under tension, using a concrete damaged plasticity (CDP) model. To this end, quantitative and qualitative analyses were performed. Numerical calculations of HSC and SFRHSC beams were made in the Abaqus/Standard [36] program while using the CDP model.
The following assumptions were made in the numerical calculations: the influence of steel fibres on the behaviour of the composite was taken into account on the basis of calculated composite fracture energy (Gf); attention was focused on physical nonlinearity describing HSC and SFRHSC; nonlinear effects were included using the Newton–Raphson increment-iterative method; and, the calculations were performed in the plane state of strain.
The discretization of the beam in the numerical model was performed with the use of 1539 finite elements. Plane stress elements were used, four-node with reduced integration (CPS4R), located above the notch (in the place of stress concentration–crack propagation), with a mesh size of 5 mm (dimension determined by the notch width), and three-node (CPS3), located on the remaining area of variable dimensions (5–25 mm). The mesh of finite elements and boundary conditions for the beam, which were used in numerical calculations, are shown in Figure 16. Load of the beam was carried out in a kinematic way through the task of displacement (Figure 16, point A), changeable in time. The displacement point in the model was located in accordance with the place of force effects during experimental beam testing. The displacement value was δ = 8 mm for SFRHSC beams and δ = 0.1 mm for HSC beams. The size of the load increment in the range and 0.001 , 1 E 10 the maximum number of load steps of 5000 were assumed.
The use in numerical simulations, in the non-linear σt–εt relationship (weakening of the material), leads to highly sensitive results for the discretization of finite elements [36,37] (ambiguous response at the level of structure depends on the deformation location zone); hence, alternatively, the form of material weakening can be described with the use of fracture energy (Gf). In this case, the brittle damage is described by the dependence σ t ¯ u t p l ( σ t ¯ —effective stress), instead of σ t ¯ ε t p l , which is initiated when the crack (associated with the deformation location) begins to propagate, after the material reaches stress that is equal to the axial tensile strength (σt0). With the opening of the crack (the displacement increases), the tensile stress decreases up to the zero value, which corresponds to the maximum displacement ( u t , m a x p l ). The dissipation of energy in the creation of cracks with a unitary field is expressed by the formula:
G f = 0 u t , m a x p l σ t ¯ d u t , m a x p l .
The above dependence shows that the energy that is released during cracking (Gf) is equal to the value of the area under the curve σ t ¯ u t p l , and the curves themselves may assume different forms of weakening, e.g., linear or exponential.
The force-displacement at the construction level does not depend on the finite element discretization given the above relationships [37]. Due to its simplicity, this modelling method is often used in commercial FEM programs [38]. The shortcomings of the method involve limiting the location zone to one row of elements and reducing its width along with the compaction of the mesh, instead of remaining constant. It should be noted that the above limitations do not affect the mathematical model of non-linear deformations related to cracking or damage [36,37]. An improved continuous medium model can be used in order to eliminate irregularities in the mathematical model for weakened material (getting rid of the pathological dependence of the discrete solution on the mesh) [39,40].

3.2. Material Model

For the numerical analysis of HSC and SFRHSC beams, the default values of the model parameters were adopted, defining its operation in a complex stress state (β, є, f, Kc, μ) [36], and they are shown in Table 5. It has been assumed that according to the standard [18], the Poisson’s ratio of uncracked concrete equals 0.2.
In Table 5: β—the pitch of the hyperbolic asymptote of the Drucker–Prager surface to the hydrostatic axis, as measured in the meridional plane; є—eccentricity of the plastic potential, being a small positive value characterizing the speed at which the hyperbole of the plastic potential is approaching its asymptote; f—a number defining the quotient of the limit compressive stress in the biaxial state to the limit compressive stress in the uniaxial state; Kc—a parameter defining the shape of the surface of the plastic potential on the deviatorial plane, which depends on the third invariant of the stress state; and, μ—a viscous parameter, allowing to barely exceed the surface of plastic potential, in some sufficiently small steps of the task.
Density (ρ), the modulus of elasticity (Ecm), and compressive strength (fcm) of individual composite series were adopted on the basis of experimental tests (see point 3.1). In identifying the parameters in the uniaxial state of compression (σc–ε) of A, B, and C beams, it was assumed that concrete behaves in a linear elastic manner to linear stress 0.6 fcm [41], and it is then strengthened to the stresses equal to fcm, which corresponds to strains that are equal to εc,in = 1.5‰.
The material degradation associated with crushing of concrete was ignored (dc = 0), owing to the obtained failure mode of beams triggered off by cracking during tension. By tension, linear form of composite weakening ( σ t u t p l ) was assumed, as in Figure 17. In this case, the constitutive parameter defining destruction during tension, destructive displacement ( u t p l ), was determined according to the relationship [36]:
u t , m a x p l = 2 G f σ t 0 .
For calculations u t , m a x p l , the average values of fracture energy of individual series of beams (A, B, and C) were taken; they come from Table 4. Owing to the lack of own tests of axial tensile strength of SFRHSC samples, the parameter σt0 was determined on the basis of the results of the proportionality limit (fct,fl,L) [15] and then, owing to the complexity of the problem of determining the relationship σt0–fct,fl,L as well as the small number of experimental studies in this respect, a simplification was made that consisted of accepting the estimate based on the Raphael dependency [42], based against on Navier’s hypothesis (dependence obtained on the basis of tests for concrete without fibres):
σ t 0 = 0.75 f c t , f l , L .
In the case of HSC beams, the parameter σt0 was calculated in an analogous way, with flexural tensile strength (fct,fl). An arbitrary stress of 0.01 σt0 was accepted and material degradation of dt = 0.95 was assumed in order to avoid loss of convergence due to zero stress and stiffness. Table 6 presents details of the material parameters implemented for each series of beams.

3.3. Results of Numerical Analyses

A comparative analysis was carried out in order to verify the numerical model, which included the relationships F–δ and F–CTOD (quantitative analysis) and crack propagation (qualitative analysis). The analysis was performed on the basis of the arithmetic mean of beam results for each series. In Figure 18 and Figure 19, the static equilibrium path (F–δ) of the FEM model was compared with the experimental results that refer to the HSC and SFRHSC beams, respectively. In turn, numerical and experimental F–CTOD curves were compared in Figure 20 and Figure 21.
The comparative analysis of the relationships F–δ and F–CTOD confirms reliable compatibility of the obtained results of experimental and numerical test on SFRHSC beams. Compatibility can be observed both for the limit load (load-bearing capacity) and the behaviour of beams in the beyond-elastic range. In the case of HSC beams, there are some differences in the elastic work of the structure. This could be due to the influence of the test methodology on the value of the modulus of elasticity (Ec). The obtained numerical results confirm the overall compatibility of the computational model with assumptions regarding the material strength hypothesis. The differences between the experimental stiffness of the beams and the stiffness of the beams in the numerical model are also illustrated in the graphs. It confirms the correct selection of the degradation variable in the concrete model dt and the right assumption of simulating the fibres in the material based on the fracture energy.
The comparative analysis of the cracking in the beams, for the clarity of the argument, was limited to two cases: series A and C (the largest volume share of fibres in the composite and their absence). The analysis was made on the basis of damage map comparison, being defined by changes in the value of parameter DAMAGET (dt degradation of stiffness illustrating the destruction of material). The damage maps were prepared for the characteristic points of the static balance paths of HSC and SFRHSC beams (points 1, 2, and 3 marked in Figure 18 and Figure 19), which are shown in Figure 22 and Figure 23, respectively. The FEM images of the damaged HSC and SFRHSC beams were compared to images that were obtained during the experiment (Figure 22 and Figure 23).
Since, in the CDP model, it is not possible to shape cracks in a discrete way, taking into account the chipping of the material, damage maps (DAMAGET) should be identified with the gradual exclusion of finite elements from cooperation. In this way, their specific ‘gluing’ and further participation in the transmission of deformations to adjacent elements takes place. This imperfection does not have a significant impact upon the behaviour of the entire research element (convergence of static equilibrium pathways) [43].
In numerical analyses, the obtained damage images qualitatively correspond to the crack propagation images, which were obtained during experimental studies (Figure 22—SFRHSC beam and Figure 23—HSC beam). Moreover, the analysis of damage maps that were defined by the parameter dt made it possible to follow the process of crack formation and development with the increasing load of the model. For the SFRHSC beam model (C series), the development of the fracture process zone (crack range) was “smooth” (successive elimination of finite elements from cooperation), which should be identified as crack propagation due to gradual force transmission through the fibres and crack propagation was rapid and violent in the case of the HSC beam (A series).

4. Final Conclusions

On the basis of the presented research results, performed analyses, and literature review, the following conclusions were formulated:
The tests that were carried out on beams have shown that together with the increase in the volumetric amount of fibres (Vf) in the beam, flexural tensile strength increases considerably (fct,fl).
Laboratory tests carried out showed considerably higher (over two hundred times) fracture energy (Gf) in the case of SFRHSC beam as opposed to HSC beams.
The presence of fibres affects the destruction characteristics of SFRHSC beams, which do not suddenly divide in contrast to HSC ones. After they are “destroyed”, the SFRHSC beams are able to carry a set load (usually smaller than the breaking load) until the broken parts are “separated”.
Regression Equations (2), (3), and (7) with determination coefficients R2 > 85% and statistically significant structural parameters were obtained as a result of statistical analysis of the test results (fct,fl, fc and Gf). These equations can be used to estimate the flexural tensile strength (fct,fl) and fracture energy (Gf) for SFRHSC beams. In view of the sample size (≤9), the proposed regression equations should be verified in the future by performing experimental tests on a larger number of samples.
For SFRHSC beams, the force–deflection (F–δ) and force-crack tip opening displacement (F–CTOD) relationships were almost identical (shape and area under the graph). The relationship between the deflection and crack tip opening displacement (δ–CTOD) obtained for the mean results of B- and C-series beams is described by linear regression Equations (4) and (5). These equations could be a contribution to the extension of the standard [15], which now allow for approximating the deflections (δ) of steel-fibre-modified beams only as a function of crack mouth opening displacement (CMOD).
Numerical analysis of HSC and SFRHSC beams with the use of the CDP model showed high compliance with the experimental results in terms of quantity (conformity of the F–δ and F–CTOD relationships) and quality (image of the cracking).
Minor differences between the results of laboratory tests and numerical analyses of HSC and SFRHSC beams confirm the reliability of the parameters adopted, experimentally and theoretically determined, and describing the elastic-plastic material model used in numerical simulations.
The basic material parameter used in numerical simulations (CDP model), which is employed to describe the behaviour of SFRHSC beams in the beyond-elastic range is the fracture energy (Gf), takes into account the presence of fibres in the composite. To determine the energy, it is necessary to know, for example, the relationship: F–δ, F–CMOD or F–CTOD.

Author Contributions

Conceptualization, C.B. and M.K. (Maciej Kaźmierowski); Investigation, M.K. (Maciej Kaźmierowski); Methodology, C.B.; Supervision, M.K. (Mieczysław Kamiński); Validation, C.B.; Visualization, M.K. (Maciej Kaźmierowski) and M.D.; Writing—original draft, M.K. (Maciej Kaźmierowski). All authors have read and agreed to the published version of this manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Mudadu, A.; Tiberti, G.; Germano, F.; Plizzari, G.; Morbi, A. The effect of fiber orientation on the post-Cracking behavior of steel fiber reinforced concrete under bending and uniaxial tensile tests. Cem. Concr. Compos. 2018, 93, 274–288. [Google Scholar] [CrossRef]
  2. Prebhakumari, K.; Jayakumar, P. Fracture Parameters of Steel Fibre Reinforced High Strength Concrete by Size Effect Method. Int. J. Sci. Eng. Res. 2013, 4, 254–259. [Google Scholar]
  3. Fantilli, A.; Chiaia, B.; Gorino, A. Fiber volume fraction and ductility index of concrete beams. Cem. Concr. Compos. 2016, 65, 139–149. [Google Scholar] [CrossRef]
  4. Lantsoght, E. How do steel fibers improve the shear capacity of reinforced concrete beams without stirrups? Compos. Part B Eng. 2019, 175, 107079. [Google Scholar] [CrossRef]
  5. Berkowski, P.; Kosior-Kazberuk, M. Effect of Fiber on the Concrete Resistance to Surface Scaling Due to Cyclic Freezing and Thawing. Procedia Eng. 2015, 111, 121–127. [Google Scholar] [CrossRef] [Green Version]
  6. Eik, M.; Puttonen, J.; Herrmann, H. An orthotropic material model for steel fibre reinforced concrete based on the orientation distribution of fibres. Compos. Struct. 2015, 121, 324–336. [Google Scholar] [CrossRef]
  7. Tlemat, H.; Pilakoutas, K.; Neocleus, K. Modelling of SFRC using Inverse Finite Element Analysis. Mater. Struct. 2006, 39, 197–207. [Google Scholar] [CrossRef]
  8. Ezeldin, A.; Balaguru, P. Normal and high strength fiber reinforced concrete under compression. J. Mater. Civil Eng. 1992, 4, 415–429. [Google Scholar] [CrossRef]
  9. Abbass, W.; Khan, M.; Mourad, S. Evaluation of mechanical properties of steel fiber reinforced concrete with different strengths of concrete. Constr. Build. Mater. 2018, 168, 556–569. [Google Scholar] [CrossRef]
  10. Sivaraja, M.; Kandasamy, S.; Thirumurugan, A. Mechanical strength of fibrous concrete with waste rural materials. J. Sci. Ind. Res. 2010, 69, 308–312. [Google Scholar]
  11. Kazmierowski, M. Deflections of Double-Span Reinforced Concrete Beams Made of High-Strength Concrete Modified with Steel Fibers. Ph.D. Thesis, Wroclaw University of Technology, Wroclaw, Poland, July 2019. [Google Scholar]
  12. Banthia, N. Fiber Reinforced Cements and Concretes. Can. J. Civ. Eng. 2001, 28, 879–880. [Google Scholar]
  13. Hameed, R.; Turatsinze, A.; Duprat, F.; Sellier, A. Metallic fiber reinforced concrete: Effect of fiber aspect ratio on the flexural properties. J. Eng. Appl. Sci. 2009, 4, 67–72. [Google Scholar]
  14. Bencardino, F. Mechanical Parameters and Post-Cracking Behaviour of HPFRC according to Three-Point and Four-Point Bending Test. Adv. Civ. Eng. 2013. [Google Scholar] [CrossRef] [Green Version]
  15. European Committee for Standardization. Test Method for Metallic Fibered Concrete–Measuring the Flexural Tensile Strength (Limit of Proportionality (LOP), Residual); EN 14651:2005; European Committee for Standardization: Brussels, Belgium, 2005. [Google Scholar]
  16. National Research Council. Guide for the Design and Construction of Fiber-Reinforced Concrete Structures; CNR-DT 204/2006; National Research Council: Rome, Italy, 2007. [Google Scholar]
  17. European Committee for Standardization. Testing Hardened Concrete, Part 2: Making and Curing Specimens for Strength Tests; EN 12390-2:2000; European Committee for Standardization: Brussels, Belgium, 2000. [Google Scholar]
  18. Polish Committee for Standardization. Eurocode 2: Design of Concrete Structures-Part 1-1: General Rules and Rules for Buildings; PN-EN 1992-1-1: 2008; Polish Committee for Standardization: Warsaw, Poland, 2010. [Google Scholar]
  19. European Committee for Standardization. Fly Ash for Concrete–Part 1: Definitions, Specifications and Conformity Criteria; EN 450-1: 2012; European Committee for Standardization: Brussels, Belgium, 2012. [Google Scholar]
  20. European Committee for Standardization. Testing Fresh Concrete, Part 2: Slump-Test; EN 12350-2:2009; European Committee for Standardization: Brussels, Belgium, 2009. [Google Scholar]
  21. European Committee for Standardization. Testing Hardened Concrete, Part 3: Compressive Strength of Test Specimens; EN 12390-3:2009; European Committee for Standardization: Brussels, Belgium, 2009. [Google Scholar]
  22. European Committee for Standardization. Testing Hardened Concrete, Part 13: Determination of Secant Modulus of Elasticity in Compression; EN 12390-13:2013; European Committee for Standardization: Brussels, Belgium, 2013. [Google Scholar]
  23. Lambrechts, A. Performance classes for steel fibre reinforced concrete: Be critical. In Proceedings of the BEFIB 2008: 7th RILEM International Symposium on Fibre Reinforced Concrete, Chennai, India, 17–19 September 2008. [Google Scholar]
  24. Ponikiewski, T.; Katzer, J. Mechanical Properties and Fibre Density of Steel Fibre Reinforced Self-Compacting Concrete Slabs by Dia and Xct Approaches. J. Civ. Eng. Manag. 2017, 23, 604–612. [Google Scholar] [CrossRef]
  25. Wafa, F.; Ashour, S. Mechanical Properties of High-Strength Fiber Reinforced Concrete. ACI Mater. J. 1992, 89, 449–455. [Google Scholar]
  26. Kaiss, S.; Al-Azzawi, K. Mechanical Properties of High-Strength Fiber Reinforced Concrete. Eng. Technol. J. 2010, 28, 2442–2453. [Google Scholar]
  27. Sumathi, A.; Saravana, K. Strength Predictions of Admixed High Performance Steel Fiber Concrete. ChemTech 2014, 6, 4729–4736. [Google Scholar]
  28. Eren, O.; Marrar, K.; Celik, T. Effect of Silica Fume and Steel Fibers on Some Properties of High-Strength Concrete. Constr. Build. Mater. 1997, 11, 373–382. [Google Scholar] [CrossRef]
  29. Lin, W.; Wu, Y.; Cheng, A.; Chao, S.; Hsu, H. Engineering Properties and Correlation Analysis of Fiber Cementitious Materials. Materials 2014, 7, 7423–7435. [Google Scholar] [CrossRef] [Green Version]
  30. Gao, J.; Sun, W.; Morino, K. Mechanical properties of steel fibre reinforced high strength light weight concrete. Cem. Concr. Compos. 1997, 19, 307–313. [Google Scholar] [CrossRef]
  31. Bayramov, F.; Tasdemir, C.; Tasdemir, M. Optimisation of steel fibre reinforced concretes by means of statistical response surface method. Cem. Concr. Compos. 2004, 26, 665–675. [Google Scholar] [CrossRef]
  32. Bae, B.; Choi, H.; Choi, C. Correlation Between Tensile Strength and Compressive Strength of Ultra High Strength Concrete Reinforced with Steel Fiber. J. Korea Concr. Inst. 2015, 27, 253–263. [Google Scholar] [CrossRef]
  33. Hillerborg, A.; Modéer, M.; Petersson, P. Analysis of crack formation and crack growth in concrete by means of fracture mechanics and finite elements. Cem. Concr. Res. 1976, 6, 773–780. [Google Scholar] [CrossRef]
  34. RILEM TC-FMC. Determination of fracture energy of mortar and concrete by means of three-Point bend test on notched beams. Mater. Struct. 1985, 18, 285–290. [Google Scholar] [CrossRef]
  35. Spagnoli, A.; Carpinteri, A.; Ferretti, D.; Vantadori, S. An experimental investigation on the quasi-Brittle fracture of marble rocks. Fatigue Fract. Eng. Mater. Struct. 2016, 8, 956–968. [Google Scholar] [CrossRef]
  36. Abaqus User’s Manual; Version 6.14; Dassault Systèmes Simulia Corp: Johnston, RI, USA, 2014.
  37. Pamin, J.; Winnicki, A. Computational models of materials: Damage, strain localization, applications. In Modern Structural Mechanics with Applications to Civil Engineering; Polish Academy of Sciences: Warsaw, Poland, 2015; pp. 259–278. [Google Scholar]
  38. Diana Finite Element Analysis User’s Manual. Theory; Release 9.6; TNO DIANA BV: Delft, The Netherlands, 2014.
  39. Wosatko, A.; Genikomsou, A.; Pamin, J.; Polak, M.A.; Winnicki, A. Examination of two regularized damage-plasticity models for concrete with regard to crack closing. Eng. Fract. Mech. 2018, 194, 190–211. [Google Scholar] [CrossRef]
  40. Wosatko, A.; Winnicki, A.; Polak, M.A.; Pamin, J. Role of dilatancy angle in plasticity-Based models of concrete. Arch. Civ. Mech. Eng. 2019, 19, 1268–1283. [Google Scholar] [CrossRef]
  41. Jankowiak, T. Failure Criteria for Concrete under Quasi-Static and Dynamic Loadings, 1st ed.; Politechnika Poznanska: Poznan, Poland, 2011; pp. 47–96. ISBN 978-83-7143-981-0. [Google Scholar]
  42. Raphael, J. Tensile strength of concrete. Concr. Int. 1984, 81, 158–165. [Google Scholar]
  43. Sledziewski, K. Experimental and numerical studies of continuous composite beams taking into consideration slab cracking. Maint. Reliab. 2016, 18, 578–589. [Google Scholar] [CrossRef]
Figure 1. Cross-section of the three-point bending steel fibre reinforced concrete (SFRC) or steel fibre reinforced high-strength concrete (SFRHSC) beam before failure.
Figure 1. Cross-section of the three-point bending steel fibre reinforced concrete (SFRC) or steel fibre reinforced high-strength concrete (SFRHSC) beam before failure.
Materials 13 01631 g001
Figure 2. Test setup project: 1 and 6—sensors for measuring notch opening width (CTOD), 2–5—sensors for measuring deflection measurement (δ), 7—aluminum profile, 8—aluminum flat bar, and 9—notch.
Figure 2. Test setup project: 1 and 6—sensors for measuring notch opening width (CTOD), 2–5—sensors for measuring deflection measurement (δ), 7—aluminum profile, 8—aluminum flat bar, and 9—notch.
Materials 13 01631 g002
Figure 3. Flexural tensile strength test (fct,fl): (a) C2 beam; (b) location of sensors for measuring deflections (No. 2 and 5) and notch opening (No. 1) in C1 beam.
Figure 3. Flexural tensile strength test (fct,fl): (a) C2 beam; (b) location of sensors for measuring deflections (No. 2 and 5) and notch opening (No. 1) in C1 beam.
Materials 13 01631 g003
Figure 4. Flexural tensile strength results (fct,fl), depending on the fibre reinforcement ratio (Vfl/d), the regression curve, and 95% confidence curves.
Figure 4. Flexural tensile strength results (fct,fl), depending on the fibre reinforcement ratio (Vfl/d), the regression curve, and 95% confidence curves.
Materials 13 01631 g004
Figure 5. Flexural tensile strength results (fct,fl) depending on compression strength (fc) and fibre reinforcement ratio (Vfl/d).
Figure 5. Flexural tensile strength results (fct,fl) depending on compression strength (fc) and fibre reinforcement ratio (Vfl/d).
Materials 13 01631 g005
Figure 6. Force–deflection relationships for SFRHSC beams (B and C series, curve C2 coincides with curve B3).
Figure 6. Force–deflection relationships for SFRHSC beams (B and C series, curve C2 coincides with curve B3).
Materials 13 01631 g006
Figure 7. Force–deflection relationships for HSC beams (series A) and curve F–δ obtained on the basis of the arithmetic mean of results (continuous line).
Figure 7. Force–deflection relationships for HSC beams (series A) and curve F–δ obtained on the basis of the arithmetic mean of results (continuous line).
Materials 13 01631 g007
Figure 8. Force–deflection relationships obtained on the basis of the arithmetic mean of the results for beams from series A, B, and C.
Figure 8. Force–deflection relationships obtained on the basis of the arithmetic mean of the results for beams from series A, B, and C.
Materials 13 01631 g008
Figure 9. Force-crack tip opening displacement relationships of SFRHSC beams (B and C series).
Figure 9. Force-crack tip opening displacement relationships of SFRHSC beams (B and C series).
Materials 13 01631 g009
Figure 10. Force-crack tip opening displacement relationships of HSC beams (series A) and the F–CTOD curve obtained on the basis of the arithmetic mean of the results (continuous line, curve A1 coincides with curve Am).
Figure 10. Force-crack tip opening displacement relationships of HSC beams (series A) and the F–CTOD curve obtained on the basis of the arithmetic mean of the results (continuous line, curve A1 coincides with curve Am).
Materials 13 01631 g010
Figure 11. Force-crack tip opening displacement relationships obtained on the basis of the arithmetic mean of the results for beams in series A, B and C.
Figure 11. Force-crack tip opening displacement relationships obtained on the basis of the arithmetic mean of the results for beams in series A, B and C.
Materials 13 01631 g011
Figure 12. Deflections–crack tip opening displacement relationship of B-series beams and δ–CTOD curve obtained on the basis of the arithmetic mean of results (Bm).
Figure 12. Deflections–crack tip opening displacement relationship of B-series beams and δ–CTOD curve obtained on the basis of the arithmetic mean of results (Bm).
Materials 13 01631 g012
Figure 13. Deflection–crack tip opening displacement relationships of C-series beams and the relationship δ–CTOD obtained on the basis of the arithmetic mean of results (Cm).
Figure 13. Deflection–crack tip opening displacement relationships of C-series beams and the relationship δ–CTOD obtained on the basis of the arithmetic mean of results (Cm).
Materials 13 01631 g013
Figure 14. Damaged beams; from left: beam C2; beam A1 (no fibres); series A; series C.
Figure 14. Damaged beams; from left: beam C2; beam A1 (no fibres); series A; series C.
Materials 13 01631 g014
Figure 15. HSC and SFRHSC beams’ fracture energy results (Gf) depending on fibre reinforcement ratio (Vfl/d) and polynomial regression Equation (7).
Figure 15. HSC and SFRHSC beams’ fracture energy results (Gf) depending on fibre reinforcement ratio (Vfl/d) and polynomial regression Equation (7).
Materials 13 01631 g015
Figure 16. Finite-element mesh and boundary conditions for the beam used in numerical calculations.
Figure 16. Finite-element mesh and boundary conditions for the beam used in numerical calculations.
Materials 13 01631 g016
Figure 17. Linear weakening during tension.
Figure 17. Linear weakening during tension.
Materials 13 01631 g017
Figure 18. Comparison of numerical and experimental force–deflection relationship of SFRHSC beams in a three-point bending tests (B and C series).
Figure 18. Comparison of numerical and experimental force–deflection relationship of SFRHSC beams in a three-point bending tests (B and C series).
Materials 13 01631 g018
Figure 19. Comparison of numerical and experimental force–deflection relationship of HSC beams in three-point bending tests (series A).
Figure 19. Comparison of numerical and experimental force–deflection relationship of HSC beams in three-point bending tests (series A).
Materials 13 01631 g019
Figure 20. Comparison of numerical and experimental force-crack tip opening displacement relationship of SFRHSC beams in three-point bending tests (B and C series).
Figure 20. Comparison of numerical and experimental force-crack tip opening displacement relationship of SFRHSC beams in three-point bending tests (B and C series).
Materials 13 01631 g020
Figure 21. Comparison of numerical and experimental force-crack tip opening displacement relationship of HSC beams in three-point bending tests (series A).
Figure 21. Comparison of numerical and experimental force-crack tip opening displacement relationship of HSC beams in three-point bending tests (series A).
Materials 13 01631 g021
Figure 22. Image of finite element method (FEM) destruction corresponding to the characteristic points of the static equilibrium path (see Figure 18) of SFRHSC beams (series C); the final image of the destruction of the tested C2 beam and the legend for the material damage map.
Figure 22. Image of finite element method (FEM) destruction corresponding to the characteristic points of the static equilibrium path (see Figure 18) of SFRHSC beams (series C); the final image of the destruction of the tested C2 beam and the legend for the material damage map.
Materials 13 01631 g022
Figure 23. Image of FEM destruction corresponding to the characteristic points of the static equilibrium path (see Figure 19) of the HSC beams (series A) and the final picture of destruction of the tested A1 beam.
Figure 23. Image of FEM destruction corresponding to the characteristic points of the static equilibrium path (see Figure 19) of the HSC beams (series A) and the final picture of destruction of the tested A1 beam.
Materials 13 01631 g023
Table 1. Scope of tests and specification of samples.
Table 1. Scope of tests and specification of samples.
Measured ParameterSample TypeSample Dimensions
(mm)
SeriesTotal
ABC
fct,fl, fct,fl,Lbeam150 × 150 × 6003339
fccube150 × 150 × 1503339
Eccylinder150 × 30055515
Table 2. Concrete mixture composition.
Table 2. Concrete mixture composition.
MaterialSeries
ABC
Steel fibreskg/m3078118
% (Vf) *01.01.5
Superplasticizerkg/m38.259.6510.80
Cement-CEM I 52.5R kg/m3550
Sand 0–2 mmkg/m3600
Granite aggregate 2–8 mmkg/m3490
Granite aggregate 8–16 mmkg/m3590
Fly ashkg/m330
Coefficient w/c-0.30
* Vf = Wff (Wf—fibre content in mass units in 1 m3; ρf—fibre material density in kg/m3).
Table 3. Test results.
Table 3. Test results.
Seriesfct,fl (MPa)fct,fl,L (MPa)fc (MPa)Ec (GPa)
ResultxsResultxsResultxsResultxs
A 5.640.30 -- 76.910.4734.5035.681.64
5.32-76.4136.90
5.69-76.9733.47
5.91-77.3436.17
37.35
B 11.001.99 6.140.70 86.841.5240.3541.081.21
8.865.3485.1941.07
11.346.4287.1639.80
12.796.6588.1742.99
41.20
C 13.091.74 7.010.51 95.560.4437.7741.762.36
11.526.4295.1941.61
12.807.2795.4443.73
14.967.3396.0442.56
43.12
Table 4. HSC and SFRHSC beams fracture energy results along with the arithmetic mean (x) and standard deviation (s) for each series (kNm/m2).
Table 4. HSC and SFRHSC beams fracture energy results along with the arithmetic mean (x) and standard deviation (s) for each series (kNm/m2).
BeamResultxs
A10.0360.04120.004
A20.043
A30.044
B17.0518.3941.16
B29.033
B39.098
C17.6888.9961.26
C29.103
C310.195
Table 5. The default parameters of the concrete damaged plasticity (CDP) model in the complex stress state.
Table 5. The default parameters of the concrete damaged plasticity (CDP) model in the complex stress state.
Name of ParameterβєfKcμ
Value36°0.11.160.6670
Table 6. Material constants adopted for the CDP model for different composite series.
Table 6. Material constants adopted for the CDP model for different composite series.
The Law of Strengthening in CompressionThe Law of Weakening in Tension
Seriesσc
(MPa)
ε c i n · 10 3 σt
(MPa)
u t p l
(mm)
dt
A46.151.294.2300
76.911.500.0420.040.95
B52.101.274.6000
86.841.500.0463.6480.95
C57.341.375.2500
95.561.500.0533.4240.95

Share and Cite

MDPI and ACS Style

Bywalski, C.; Kaźmierowski, M.; Kamiński, M.; Drzazga, M. Material Analysis of Steel Fibre Reinforced High-Strength Concrete in Terms of Flexural Behaviour. Experimental and Numerical Investigation. Materials 2020, 13, 1631. https://doi.org/10.3390/ma13071631

AMA Style

Bywalski C, Kaźmierowski M, Kamiński M, Drzazga M. Material Analysis of Steel Fibre Reinforced High-Strength Concrete in Terms of Flexural Behaviour. Experimental and Numerical Investigation. Materials. 2020; 13(7):1631. https://doi.org/10.3390/ma13071631

Chicago/Turabian Style

Bywalski, Czesław, Maciej Kaźmierowski, Mieczysław Kamiński, and Michał Drzazga. 2020. "Material Analysis of Steel Fibre Reinforced High-Strength Concrete in Terms of Flexural Behaviour. Experimental and Numerical Investigation" Materials 13, no. 7: 1631. https://doi.org/10.3390/ma13071631

APA Style

Bywalski, C., Kaźmierowski, M., Kamiński, M., & Drzazga, M. (2020). Material Analysis of Steel Fibre Reinforced High-Strength Concrete in Terms of Flexural Behaviour. Experimental and Numerical Investigation. Materials, 13(7), 1631. https://doi.org/10.3390/ma13071631

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.