Next Article in Journal
Mechanical and Durability Properties of Portland Limestone Cement (PLC) Incorporated with Nano Calcium Carbonate (CaCO3)
Next Article in Special Issue
Effects of Amorphous Poly Alpha Olefin (APAO) and Polyphosphoric Acid (PPA) on the Rheological Properties, Compatibility and Stability of Asphalt Binder
Previous Article in Journal
Effect of Different Cooling Strategies on Surface Quality and Power Consumption in Finishing End Milling of Stainless Steel 316
Previous Article in Special Issue
Strength Parameters of Foamed Geopolymer Reinforced with GFRP Mesh
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Research on the Thermal Properties of Fireplace Concrete Materials Containing Various Mineral Aggregates Enriched by Organic and Inorganic Fibers

1
Faculty of Mining and Geoengineering, AGH University of Science and Technology, Mickiewicza 30 Av., 30-094 Krakow, Poland
2
Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30 Av., 30-094 Krakow, Poland
3
Northstar Poland, 27 Stycznia 47-48 St., 64-980 Trzcianka, Poland
*
Author to whom correspondence should be addressed.
Materials 2021, 14(4), 904; https://doi.org/10.3390/ma14040904
Submission received: 7 December 2020 / Revised: 5 January 2021 / Accepted: 9 February 2021 / Published: 14 February 2021
(This article belongs to the Special Issue Research and Development of Modified Building Materials)

Abstract

:
This work presents a summary of research on concrete fireplace materials made of various mineral aggregates and enriched with steel and organic fibers. To determine the optimal applications of such concretes, their ability to accumulate heat and their other physicochemical parameters were tested and analyzed. Studies on the behavior of concrete materials during cooling are reported, and the ability of such materials to accumulate heat is evaluated using calculations. In addition, tests were performed on the loss of mass during heating, as well as on the mechanical bending strength and microstructures of these materials. Studies have shown that the behavior of concrete materials at high temperatures can be modified and adapted for specific purposes. The addition of fibers to concrete improves both the mechanical properties of mortars and the heat flow in concrete materials.

1. Introduction

Over recent decades, the energy demands in residential buildings have increased, and there is now a great need to balance energy consumption. Energy-efficient buildings are becoming increasingly desirable due to rising energy costs and increasing awareness of global warming [1]. The thermal properties of concrete materials are attracting increasingly more attention, not only because of their influence on the energy efficiency of buildings but also due to the structural properties and functionality of such materials. Modern concrete materials containing various complementary cement materials, various types of aggregates (including light and recycled aggregates), and fibers are increasingly used in transport structures such as sidewalks and bridge decks, as well as in large foundations (ready-mixed concrete), where thermal behavior is important and sensitive to construction properties [2]. However, there are few publications on the heat-accumulation properties of concrete elements used in fireplaces. Usually, the attention is focused on the role of the thermal conductivity coefficient in the insulation of buildings, and information can also be found on the behavior of concrete at high temperatures above 500 °C, for which the strong influence of the aggregates used and effective reinforcement with steel and polypropylene fibers are highlighted [3]. The type of aggregate is also important in concretes operating at increased temperatures. Fine aggregates based on sand show a polymorphic transformation at 573 °C and have a high coefficient of thermal expansion, which causes micro-cracking in the material and weakening of the structure [4]. Interesting results were also obtained by examining the compressive strength and pore distribution in concrete working at above 500 °C [5,6]. The addition of expanded glass to concrete also significantly reduces thermal conductivity [7], so such materials have good heat accumulation capacities [8]. This publication focuses on concrete materials designated for heating devices. Heating furnaces are usually made of natural soapstone (a green–grey rock containing mainly magnesium aluminosilicates), which has a very good thermal accumulation capacity. In these furnaces, thanks to the accumulation capacity of soapstone and technical solutions (e.g., multiple circulation and swirling of flue gases), the temperature in the furnace reaches about 1200 °C (normally about 600 °C), which enables the combustion of flue gases (burning of soot). This results in high furnace efficiency and has a positive impact on the environment [9]. The temperatures in accumulation furnaces reach 400 °C and higher. Simple concrete is rarely used as a material in these furnaces due to its low resistance to such temperatures (the safe temperature limit is 450 °C). This is why ceramics are used in these applications, as ceramics are much more resistant to high temperatures, especially chamotte. The behavior of cement mortars at high temperatures can also be modified and adapted for specific purposes. For this purpose, it is worthwhile to trace the physicochemical processes that occur under the influence of high temperatures.
To control the process of thermal accumulation, it is necessary to determine the thermal phenomena and transformations taking place in the materials. The energy absorbed by a body during heating or lost during cooling is proportional to the product of the body weight m and the temperature difference of the body ΔT before and after the thermal transformation. The principle of thermal conversion ability ΔQ can be rendered as [10]:
ΔQ = cv × m × ΔT (J)
where the cv capacity of a substance is considered the amount of heat needed to raise the temperature of the substance by one degree. The thermal capacity, which is measured per unit of mass of a substance, is called specific heat cp (expressed in J/kgK). This quantity is not a constant value and depends primarily on temperature (Figure 1) [11]. In many amorphous, glassy, and crystalline substances, the specific heat increases simultaneously with a temperature increase, as well as at high temperatures.
Another value that characterizes materials in terms of their thermal properties is their thermal volume capacity. The value b is calculated as the product of the thermal capacity cv and the density ρ of the material from which the body is made:
b = cv × ρ (J/(m3K))
The values of thermal capacity b for building materials can be very different, ranging from about 25 kJ/m3K for insulation materials to almost 3000 kJ/m3K for heat accumulators. For example, for ordinary chamotte bricks, the thermal energy accumulated in a unit of volume is about 1000 kJ/m3K, while for concretes resistant to high temperatures, with the same volume, much more energy can be accumulated (~2700 kJ/m3K). In general, heat-resistant concretes can accumulate about three times more energy than ordinary chamotte coverings. The main factor influencing the value of concrete is its composition, as this capacity for concrete results from the volumetric thermal capacity of its ingredients, which are additive quantities [10,11].
Volume heat capacity is the amount of energy taken in during heating or released during cooling 1 m3 of the material, changing the material’s temperature by one degree. In other words, volume heat capacity is the energy that increases (or decreases) the temperature of a given material of a unit volume by a unit of temperature. Volume heat capacity is not sufficient, however, to describe the ability to accumulate heat. An additional parameter characterizing the efficiency of the material accumulation phenomenon is the energy that can be accumulated in a unit of the material’s volume for a certain period of time Δt. The maximum energy that can be accumulated in a given bmax material can be described by the following formula [11]:
bmax = b × Δt (J/m3)
It follows that different building and mineral materials have different capacities to store energy, the value of which determines if the material is a good heat accumulator and can be used as such in space-heating systems. An important element for thermal properties is the use of natural [3], light [12,13], hybrid [14], or recycled [15,16] aggregates. The properties of concrete materials with rubber waste particles were also studied [17]. In the literature review, studies on the thermal properties of concretes and mortars containing recycled glass as fine aggregates [18] and reinforced concretes containing steel, plastic, and glass fibers [19] were found. Concrete is a multi-phase and complex system. Therefore, numerical methods based on multi-species modeling seem very promising for the analysis of concrete [20]. Numerical simulations have been widely used to analyze the influence of aggregates on the transport properties in concrete, including heat transport. These methods allow one to predict the important properties of concretes such as their resistance to chloride corrosion [21], which is significantly influenced by temperature [22], as well as the shapes of the aggregate grains [23,24].
Another parameter that determines the thermal properties of materials is the time needed to release (emission) the accumulated energy. With a given amount of accumulated energy, the emission time of that energy must not be too short (or too much heat will be released in a unit of time) or too long (or too little heat will be released in a unit of time and will be insufficient, e.g., for heating the room). In a thermodynamic system (e.g., in an isolated room) containing a body with a temperature higher than room temperature, entropy will strive to achieve the maximum value, i.e., the equilibrium state of the whole system, to equalize the temperature in the whole area. This process always occurs automatically and spontaneously. The phenomenon of heat transfer from the body to the system is called the emission of heat energy. The measure of thermal energy emission E is the thermal power P, which is determined by the following relation [25]:
P = E/t (J/s).
Heat-accumulating materials used in practical applications should have a relatively high heat power. The heat that is delivered to the storage material then causes a proportional increase in temperature. Sensible heat is presently the most popular method of thermal energy storage. This change can be registered with the senses or via sensors [26]. Sensible heat magazines accumulate thermal energy by heating or cooling the stored material. These magazines then use the thermal capacity and temperature changes of the material during the charging and discharging processes. The amount of accumulated heat depends on the mass and medium of heat used for storage and the temperature difference between the initial and final states [27,28]. There have also been attempts to model the behavior of concrete materials under the influence of high temperature and to estimate their mechanical properties and heat accumulation capacities [29,30].

2. Research Significance

Materials used for the construction of fireplaces should have special thermal properties which can allow for the accumulation and release of heat. Heat accumulation refers to the ability of a material to accumulate and store a certain amount of thermal energy inside itself, which can then be released for a period of time by the material. That is why we are looking for ways to accumulate heat when there is excess and use it when there is a deficiency. Foundationally, this involves finding optimal solutions from the perspective of so-called thermal comfort, i.e., obtaining and maintaining the necessary temperatures inside objects for comfortable functioning in unfavorable external conditions. One example is seasonal accumulation, which involves storing heat energy in summer and using that energy in the autumn–winter season. Reverse processes are used to cool rooms in summer conditions. The purpose of this work is to try to determine whether concretes made with mineral aggregates and various organic additives have different heat accumulation capacities. This would allow the concrete to be used not only for the manufacturing of elements, including prefabricated elements, at increased temperatures but also where such elements could accumulate and release heat (e.g., fireplace covers). Therefore, the basic parameters characterizing the usefulness of such materials, i.e., volume and mass thermal capacity, maximum heat accumulation capacity, and high temperature behavior (differential thermal analysis(DTA) tests), were assessed.

3. Materials and Methods

3.1. Materials and Mix Proportions

Samples for testing were supplied from Northstar and were used as fireplace insulation inserts. The composition of the individual concrete materials is shown in Table 1.

3.2. Research Methodology

3.2.1. Thermal Properties

There are many methods for testing the thermal properties of concrete materials [31,32,33]. In this publication, studies were carried out with the use of a thermal imaging camera NEC ThermoGear G100, which enabled the recording and visualization of temperature distribution on object surfaces (mapping thermal images of the objects). This system works on the principle of processing the infrared radiation emitted or reflected by these objects into an electrical signal and then into the image viewed on the screen as a so-called thermogram. Thermal imaging enables the detection of many properties of plastics in a way that no other technology provides. Samples of 10 cm × 10 cm were cut out of the tested concrete. Then, the samples were placed in a laboratory dryer and heated to 160 °C for 2 h. Next, the samples were taken out, immediately placed on a pedestal (Figure 2), and the temperatures were measured based on the cooling time. These tests were carried out with the use of a thermal imaging camera that was placed 70 cm from the tested sample.

3.2.2. Differential Thermal Analysis

Concrete plastics and gas emissions were examined using an STA 449 F3 Jupiter Thermal Analyzer (Netzsch) and a coupled quadrupole mass spectrometer TA-QMS Coupling (Netzsch). The measurements were carried out in alumina crucibles at a heating rate of 10 °C/min in a temperature range of 30–600 °C under an air and argon atmosphere with a constant flow of 20 mL/min. This research focused on the analysis of concrete materials 2, 3, and 5 and the influence of additives modifying the strength properties in terms of gas emissions.

3.2.3. Mechanical Pproperties

Samples for mechanical strength testing were prepared in accordance with PN-EN 206 + A1:2016–12 [34], and bending strength measurement was performed after 1, 7, and 28 days of maturation. These measurements used bars with rectangular cross-sections and dimensions of 40 × 40 × 160 mm3. The mechanical strength of the tested fireplace materials was determined using the three-point bending method. The specimen was placed in a special holder in a testing machine (Zwick/Roell 2.5, Ulm (Germany)) (Figure 3). A measurement was then performed three times.

3.2.4. Microstructure of the Fireplace Concrete

Samples of the delivered concrete materials were taken at random and analyzed on a scanning microscope equipped with an energy dispersive spectroscopy(EDS) analyzer (Ultra High Resolution Scanning Electron Microscope with Field Emission Gun (FEG)–NOVA NANO SEM 200 (manufacturer FEI EUROPE COMPANY), cooperating with an EDS analyzer by EDAX). Photographs at a magnification of about 100,000 (20,000) times are shown in Figures 5–10. Under each photograph, the EDS analysis is shown on the marked points.

4. Results

4.1. Thermal Properties

To standardize the data needed to calculate, among others, thermal parameters, the mass, volume, and density of the samples were determined (Table 2).
Table 3 outlines the temperatures obtained depending on the cooling time. At the beginning of the measurement, the temperature between measurements was measured every few seconds, every 30 s, and then every 1 min. Using the thermal imaging camera, it was possible to implement a program for reading the temperature values on the surfaces of the samples in different places (Figure 4). To calculate the thermal capacity, the value a is used, i.e., the temperature measured in the middle of the sample.
Figure 5 shows a diagram of temperature changes (value a) on the surfaces of the cooling samples.

Calculation of Heat Capacity

The specific heat is an additive quantity, i.e., each degree of freedom in a given system contributes to the total specific heat of the system, and, as a result, the total specific heat is the sum of the different contributions [35]. On the basis of the percentage content of individual raw materials (Table 1) and their table values of cv specific heat (Table 4) [36], the total specific heat of the examined materials was calculated:
cv = Σ%x × cvx
where %x is the percentage of raw material in the sample [-], and cvx is the table-specific heat value (J/kgK).
The calculations are presented in Table 5.
On the basis of the value of total specific heat Σ cv (Table 5), the mass of the tested samples m (Table 2) and ∆T (the difference in the temperature of a given body before and after thermal transformation; Table 6) and ∆Q, i.e., the change in the thermal energy of the tested materials, were calculated. The results of the calculations are presented in Table 6.
Another value that characterizes the thermal properties of materials is volumetric thermal capacity b, which describes the ability of amaterial to accumulate heat. The calculated values of the volumetric thermal capacity are shown in Table 7.
When describing the thermal properties of fireplace materials, it is also important to know the thermal power of the tested materials P, i.e., the parameter determining the transfer of heat from the body to the system. The relevant calculations are presented in Table 8.
In the initial cooling phase (up to 10 min), all analyzed samples lost heat at a similar rate; then, the trend changed. The curves in Figure 5 and the temperature values in Table 3 indicate that sample no. 4 (with 60.477% weight of sand content) lost heat the fastest, while sample no. 5 (with 32.027% weight of sodium–calcium feldspar content) lost heat the slowest.
Beyond the different compositions of the samples, this phenomenon could also be influenced by the fact that the samples differed significantly in their density. The density of sample no. 4 was 1.50 g/cm3, while that of sample no. 5 was 2.16 g/cm3. The values of their thermal parameters (thermal power, thermal volume capacity, and thermal energy), however, were found to be similar. The highest values were recorded for sample no. 5 consisting of magnesium silicates and sodium–calcium feldspar. The weakest thermal parameters were found for sample no. 4, as well as sample no. 2, which consisted mainly of cement, sand, and refractory aggregates. This is consistent with the literature data. For example, materials with the highest specific density always have the highest thermal capacity [37]. The thermal capacity of metals with a density of 7000–9000 kg/m3 is 1,500,000–3,500,000 J/(m3K). Casting rocks used as aggregates in concretes have an even smaller thermal capacity than metals (granite is about 1,800,000 J/(m3K)). Brick and sand have an even lower volumetric heat capacity at about 1,200,000 J/(m3K). For normal and refractory concrete with a density of about 2400 kg/m3, the volume heat capacity is about 2,770,000 J/(m3K) [38,39].

4.2. Differential Thermal Analysis

The thermal curve differential thermal analysis/thermal gravimetric analysis (DTA/TG), differential scanning calorimetry (DSC) analysis, and total ion current (TIC) gas emission analysis are presented in Figure 6, Figure 7 and Figure 8. Materials containing organic fibers were selected for these analyses (Table 1). Based on the performed tests, it can be concluded that the emission of the detected gases is related to the gases supplied to the sample during the sample’s heating, i.e., O2(32) and N2(28), as well as Ar(39), introduced as an inert gas to protect the microbalance. The emission of water was observed in all of the samples, and the amount of water changed successively during the heating of the samples. The highest amount of water was observed at around 140 °C, and the lowest amount, related to the dehydroxylation of the cement products, was observed at 480 °C. In the tested samples, weight loss in the temperature range of 30–600 °C was also observed. The complex endothermic effect observed in the temperature range from about 50 to about 350 °C is related to the dehydration of silicates of type C–S–H, hydrated calcium aluminates and aluminosulphates, and the decomposition of gypsum. Another endothermic effect in the temperature range from about 400 to about 410 °C is attributed to C2SH decomposition (2CaO·SiO2·H2O). The endothermic effect in the temperature range from about 490 to about 510 °C is attributed to Ca(OH)2dehydroxylation. The total weight loss of the samples varied and was 10.2% for sample 2, almost 7% for sample 3, and almost 9% for sample 5. This is due to differences in the composition of the individual materials.
The observed mass loss is different in particular types of concretes. These differences most likely result from different aging times, i.e., the time from concrete preparation to measurement (different humidity values), and different amounts and types of aggregates. In general, it can be concluded that the addition of modifiers causes an increase in the temperature of the cycle in which the DTA/DSC analysis takes place and causes an increase in the weight loss. Organic additives likely facilitate the emission of water at about 140 °C.
The tests showed that the specific heat of the concrete material strongly depends on the amount of free water that is released in the temperature range of 50–90 °C. Values of the specific heat measured by this method significantly drop at higher temperatures, which is likely related to the absorption of heat during the dehydration reactions of concrete materials.

4.3. Mechanical Properties

Table 9 shows the maximum values of the mechanical strength under bending for the tested fireplace materials after the different aging periods.
Samples 1 and 3 showed the highest mechanical strength at more than twice that of the other tested materials. Their bending strength after 28 days of aging was 12.3 and 13.2 MPa, respectively. The main additives in both samples were cement and aggregate. As a reinforcing additive, sample 1 included glass fibers, while sample 3 used glass and polypropylene fibers. Samples 2, 4, and 5 included a minor addition of steel fibers, which are also used as a strengthening additive to maintain the concrete’s structure during operations at high temperatures, causing significant stress in the system. Sample 5, despite the addition of reinforcing fibers, was characterized by low mechanical strength (4.8 MPa) due to the addition of a mafic aggregate containing more than 2% free biotite. Increased mica content causes a significant and constant decrease in compressive strength [40], which is especially important in the case of the fine aggregates (e.g., mafic sand) [41].

4.4. Microstructure of Fireplace Concrete

Scanning electron microscope(SEM) microphotographs with the energy dispersive spectroscopy (EDS)system of the tested samples are shown in Figure 9, Figure 10, Figure 11, Figure 12 and Figure 13. Based on the conducted research, it is possible to determine the compact microstructure of all of the concrete materials, except for sample 4, which is characterized by the presence of large spherical pores (Figure 12). A compact structure was also present in the concrete materials containing glass fibers (Figure 9) or polypropylene fibers (Figure 11, Figure 12 and Figure 13). Generally, a homogeneous microstructure was found in the analyzed concrete materials; however, in the case of sample 5, the uneven distribution of fibers was noted (Figure 13). There were also visible pores (except for sample 4), which may have resulted from inappropriate selection of the aggregate graining (filler) of the concrete material or deaeration. This is an important factor because the presence of pores lowers the density and thermal properties of the concrete material. EDS measurements confirmed the presence of cement-derived aluminates and aluminosilicates, as well as the presence of fibers, aggregate grains, and pigments.
Quartz grains and zirconium were present in the microstructure of sample 1 (Figure 9). Sample 3 (Figure 11) contained increased amounts of calcium aluminosilicate and strengthening organic fibers. Sample 4 (Figure 12) is a foamed concrete featuring the addition of calcium carbonate. In the composition of sample 2 (Figure 10), increased amounts of magnesium, zirconium, and calcium can be seen. In particular, in micro-area b, dolomite crystals formed with the addition of titanium white reinforced with organic fibers were found. Concrete no. 5 (Figure 13) is a typical concrete reinforced with organic fibers and aggregate, where the presence of iron comes from the minerals of the aggregate.
From an application perspective, concrete systems can be reduced to a mixture of three components: cement, fine aggregate, and water. Cement is a composite system in which aggregate grains are surrounded by a hardened cement slurry. Concrete formation is determined by the cement’s hydration reactions. Cement is a mixture of solid phases and mainly contains various types of aluminates and calcium aluminosilicates: allite C3S-(3CaO·SiO2), bellite C2S-(2CaO·SiO2), tricalcium aluminateC3A-(3CaO·Al2O3), brownmilleriteC4AF-(4CaO·Al2O3·Fe2O3), calcium oxide (free)-CaO, and gypsum-(CaSO4·0.5H2O).
Cement hydration is a multi-stage process. However, it can be assumed that the main phases of hydration are as follows:
allite:  3CaO·SiO2 + 3H2O → C1.5SH1.5 + 1.5·H2O
bellite:   2CaO·SiO2 + 2H2O → C1.5SH1.5 + 0.5 H2O
gypsum:  CaSO4·0.5H2O + 1.5H2O → CaSO4·2H2O
calcium oxide:  CaO + H2O → Ca(OH)2
The hydration of tricalcium aluminate, however, is more complicated. There are three basic stages in this process. In stage I, under the initially high concentration of gypsum, ettringiteis formed according to the following reaction:
3CaO·Al2O3 + 3CaSO4·2H2O + 26H2O →3CaO·Al2O3·3CaSO4·32H2O.
In stage II, when gypsum is lacking, a transitional phase is formed:
3CaO·Al2O3·Ca(OH)2·12H2O.
In stage III, the second stage phase reacts with ettringite, giving the low-sulfate form of aluminum sulphate according to the following reaction:
3CaO·Al2O3·3CaSO4·32H2O + 3CaO·Al2O3·Ca(OH)2·12H2O → 3CaO·Al2O3·CaSO4·12H2O + 2Ca(OH)2 + 20H2O.
The hydration of braunmillerite is similar to that of tricalcium aluminate. In the presence of gypsum and water, the following structures are formed:
4CaO·Al2O3·Fe2O3 + CaSO4·2H2O + Ca(OH)2 + aq → 3CaO·(Al2O3, Fe2O3)·3CaSO4·32H2O.
After braunmillerite is exhausted, the structure becomes 3CaO·(Al2O3,Fe2O3)·CaSO4·12H2O [42,43].
The hardened cement slurry is largely dominated by two phases: the CSH gel phase and the portlandite (Ca(OH)2) phase. There are also additional phases resulting from the hydration of tricalcium aluminate and braunmillerite. It should be noted that these phases contain large amounts of crystalline water, and this water is the main destructive factor for cement mortars at high temperatures, which accompanies the use of fireplaces and heating stoves. However, the content of elements such as magnesium, aluminum, calcium, and silicon significantly affects the thermal properties of the concrete [44].

5. Discussion

The addition of fibers to concrete improves the mechanical properties of mortars and may improve heat flow in concrete materials. At elevated temperatures, polypropylene melts and is absorbed by the surrounding cement matrix, creating a network of channels through which moisture and the resulting water vapor can flow [45]. Hardened cement mortar can also be treated as a fibrous composite in which the matrix is the hardened cement mortar. In the case of such a composite, the addition of a small amount of fibers, even with an elasticity modulus lower than that of the matrix, significantly improves the mechanical properties of the mortar. This is because during the hydration process of the paste components, a number of reactionsoccur, leading to the formation of mechanical stresses. The resulting stresses, which are related to internal contractions, are leveled until the structure stiffens. However, in the initial stage of hardening, the hardening paste has too low a mechanical strength to compensate for the stresses accompanying the hydration process (as confirmed by the results presented in Table 9).
The results of the mechanical strength after 28 days confirm this explanation. The highest bending strength was found for the samples with the highest amount of glass and polypropylene fibers, i.e., sample 1 (0.266 wt % of glass fibers) and sample 3 (0.209 wt % of glass fibers and 0.02 wt % of polypropylene fibers). The addition of fewer of these fibers or the addition of steel fibers (even in combination with glass fibers) caused more than a twofold decrease in mechanical strength in the described case, from 13.2 MPa for sample 3 to 4.7 MPa for sample 4.
When the proportion of organic fibers is so large that the fibers form a self-connected network of channels, it is known as a parallel transport model. That is, the transport of liquids and gases at temperatures above 400 °C takes place both through the network formed after melting the fibers and through the pores and cracks existing in the material. When there are fewer fibers, transport can be described by the so-called series-parallel model, where the incompletely connected network of channels is supplemented by the existing defects in the material [46,47].
The introduction of short polypropylene fibers, in addition to preventing detonation splashes during rapid heating or contact with fire, also has a very positive effect on the mechanical properties of mortars. Hardened cement mortar can be treated as a fibrous composite in which the matrix is hardened cement paste. In the case of such a composite, the addition of a small amount of fibers, even with a modulus of elasticity lower than that of the matrix, results in a significant improvement in the composite’s mechanical properties. This is because several stress reactions take place during the hydration of the cement slurry components. In the subsequent period, the stresses arising from internal contraction are leveled until the structure is stiffened. However, in the initial stage of hardening, the hardening cement slurry still has too low a mechanical strength to compensate for the stresses accompanying the hydration. This yields the formation of a micro-fracture network, leading to material defects and a loss of continuity at the microscale. The addition of fibers causes bridging of the resulting cracks, which reduces their size and improves the material’s resistance to brittle fractures [48].
However, the addition of short fibers to the cement matrix may regulate more than the matrix’s hydration and hardening properties. Through the addition of fibers with an elasticity modulus higher than the matrix modulus, the strength properties of the material can be directly modulated. The addition of such fibers ensures that the material does not disintegrate when the cement matrix breaks, allowing the matrix to still transfer some loads.
The reactions taking place in the cement during heating can be divided into five stages:
I.
At a temperature of about 100 °C, mechanically (capillary) bound moisture evaporates.
II.
At a temperature of about 200 °C, physicochemically bound water is released due to adsorption.
III.
At 400 °C, the release of chemically bound water in hydrated aluminosilicate compounds begins. This does not yet entail a significant decrease in mechanical strength.
IV.
At a temperature of about 530 °C, due to the decomposition of calcium hydroxide, mechanical strength decreases rapidly.
V.
At a temperature of about 1000 °C, the water is completely removed, and the structure disintegrates into a powder. The material sinters at even higher temperatures.
The effect of high temperature, i.e., that above 100 °C, on hardened cement material is very specific and causes the rapid desorption of moisture from the outer layers. The resulting water vapor flows towards the colder inner layers, where it is reabsorbed. As the temperature increases, the thickness of the heated layer increases. When the moisture-saturated layer does not move quickly enough, it is overtaken by the wandering temperature front, which leads to the evaporation of water at the front border and an increase in internal pressure. This creates tensile forces perpendicular to the temperature front, which in turn leads to rapid removal of the surface layers in the form of microcracks and spatters. This phenomenon mayoccur cyclically, destroying increasingly deeper layers of the material.
To counteract this phenomenon, it is necessary to improve the heat flow, which will entail a reduction in the pressure inside the heated element. The best way to do this is to create an interconnected network of channels in the material through which moisture and the resulting water vapor can flow, or toimprove the material’s thermal conductivity.
This can be achieved via the introduction of a fibrous material that melts at an elevated temperature and is easily absorbed by the surrounding cement matrix. Polypropylene is perfect for this purpose. This material melts at 170 °C, which is below the temperature at which water vapor is rapidly released and does not damage the concrete matrix. At low temperatures (<100 °C), all forms of water in concrete (capillary, adsorptive, and crystalline) become very good heat accumulators (the heat of water evaporation is approximately 80 kcal/mol). Exterior cladding concrete shapes used in furnaces are a good choice for this purpose.
Another type of thermal accumulation involves using the excess heat energy generated inside the fireplace or the stove to heat rooms over a longer timeframe. Such furnaces are made of natural soapstone (a greenish-gray rock containing mainly magnesium aluminosilicates), which has a very good heat accumulation capacity. In these furnaces, due to the accumulation capacity of soapstone and various technical solutions (e.g., the multiple circulation and swirling of exhaust gases), the temperature in the furnace can reach about 1200 °C (normally about 600 °C), which allows the so-called afterburning of exhaust gases (soot combustion). This results in high efficiency of the furnace and, above all, has a positive impact on the environment.
The temperatures in storage furnaces can reach 400 °C and higher. Ordinary concrete is rarely used as a material for furnaces due to its low resistance to such temperatures (the safe limit temperature is 450 °C). This is why, as a rule, ceramics that are much more resistant to high temperatures are used for this application, most often fireclay. In our case, sample 5 showed the highest thermal power (Table 8) (19.70 W), whereas sample 2 showed the lowestthermal power (8.55 W). In addition to the significant effect of density (sample 5—2.16 g/cm3; sample 2—1.76 g/m3), composition itself plays an important role. Sample 2 consisted mainly of cement, sand, and refractory aggregate, whereas sample 5 consisted mainly of magnesium silicates and sodium–calcium feldspar. Therefore, it is worth analyzing, in each case, the physicochemical processes thatoccur during the formation of hydration materials and their destruction under the influence of high temperatures.

6. Conclusions

Concrete elements can be successfully used in the construction of domestic fireplaces, thus taking advantage of the good heat accumulation properties of these elements. Both thermal and strength properties can be modified significantly via the addition of various aggregates as well as propylene and steel fibers. This modification consists mainly in changing the mechanisms of the heat flow and the decomposition products of concrete elements during heating—mainly water, although the density of the materials also has a significant impact.
From the perspective of thermal energy use, our study showed the clear advantage of concrete materials containing magnesium and sodium–calcium aggregates (feldspars). The highest values were recorded for sample 5 (which contained over 70% of the listed components). In turn, from the perspective of mechanical properties, samples 1 and 3 showed the highest mechanical strength and were reinforced with glass and polypropylene fibers, respectively. The results, however, depend on the applied temperature range. Therefore, in the case of fireplaces, it is suggested to use different multi-layer systems of concrete materials to enable the long-term heating of rooms via heat accumulation.

Author Contributions

Conceptualization, A.S., J.M.-P. and P.I.; methodology, J.M.-P., Ł.W., and T.G.; software, A.S.; validation, A.S., P.I., and J.M.-P.; formal analysis, J.M.-P., Ł.W., and T.G.; investigation, A.S. and J.M.-P.; writing—original draft preparation, A.S.; writing—review and editing, J.M.-P.; visualization, A.S.; supervision, M.K. and P.I. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author. The data are not publicly available due to the agreement with Northstar Poland.

Acknowledgments

We would like to thank Northstar Poland for its cooperation and for providing research materials.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Rao, V.V.; Parameshwaran, R.; Ram, V.V. PCM-mortar based construction materials for energy effcient buildings: A review on research trends. Energy Build. 2018, 158, 95–122. [Google Scholar] [CrossRef]
  2. Sargam, Y.; Wang, K.; Alleman, J.E. Effects of Modern Concrete Materials on Thermal Conductivity. Am. Soc. Civil Eng. 2020. [Google Scholar] [CrossRef]
  3. Kakae, N.; Miyamoto, K.; Momma, T.; Sawada, S.; Kumagai, H.; Ohga, Y.; Hirai, H.; Abiru, T. Physical and thermal properties of concrete subjected to hightemperature. J. Adv. Concr. Technol. 2017, 15, 90–212. [Google Scholar] [CrossRef] [Green Version]
  4. An, J.; Kim, S.S.; Nam, B.H.; Durham, S.A. Effect of Aggregate Mineralogy and Concrete Microstructure on Thermal Expansion and Strength Properties of Concrete. Appl. Sci. 2017, 7, 1307. [Google Scholar] [CrossRef] [Green Version]
  5. Chan, Y.N.; Lou, X.; Sun, W. Compressive strength and pore structure of high-performance concrete after exposure to high temperature up to 800 °C. Cem. Concr. Res. 2000, 30, 247–251. [Google Scholar] [CrossRef]
  6. Chan, Y.N.; Peng, G.F.; Anson, M. Residual strength and pore structure of high-strength concrete after exposure to high temperatures. Cem. Concr. Compos. 1999, 34, 1065–1069. [Google Scholar] [CrossRef]
  7. Yousefi, A.; Tang, W.; Khavarian, M.; Fang, C.; Wang, S. Thermal and Mechanical Properties of Cement Mortar Composite Containing Recycled Expanded Glass Aggregate and Nano Titanium Dioxide. Appl. Sci. 2020, 10, 2246. [Google Scholar] [CrossRef] [Green Version]
  8. Krishnamoorthy, R.R.; Zujip, J.A. Thermal conductivity and microstructure of concrete using recycle glass as a fine aggregate replacement. Int. J. Emerg. Technol. Adv. Eng. 2013, 3, 463–471. [Google Scholar]
  9. Huhta, A.; Karki, A.; Hanski, E. A new method for testing thermal shock resistance properties of soapstone—Effects of microstructures and mineralogical variables. Bull. Geol. Soc. Finl. 2016, 88, 21–46. [Google Scholar] [CrossRef]
  10. Garbalińska, H.; Bochenek, M. Thermal insulation and thermal accumulation of selected wall materials. In Technical Transactions Architecture; Publishing Cracow University of Technology: Krakow, Poland, 2011; Volume 11, pp. 89–96. [Google Scholar]
  11. Szargut, J. TermodynamikaTechniczna; WydawnictwoPolitechnikiŚląskiej: Gliwice, Poland, 2000. [Google Scholar]
  12. Cavalline, T.L.; Castrodale, R.W.; Freeman, C.; Wall, J. Impact of lightweight aggregate on concrete thermal properties. ACI Mater. J. 2017, 114, 945–956. [Google Scholar] [CrossRef]
  13. Roberz, F.; Loonen, R.C.G.M.; Hoes, P.; Hensen, J.L.M. Ultra-lightweight concrete: Energy and Comfort performance evaluation in relation to buildings with low and high thermal mass. Energy Build. 2017, 138, 432–442. [Google Scholar] [CrossRef]
  14. Marie, I. Thermal conductivity of hybrid recycled aggregate—Rubberized concrete. Constr. Build. Mater. 2017, 133, 516–524. [Google Scholar] [CrossRef]
  15. Bravo, M.; Brito, J.D.; Evangelista, L. 2017 Thermal Performance of Concrete with Recycled Aggregates from CDW Plants. Appl. Sci. 2017, 7, 740. [Google Scholar] [CrossRef] [Green Version]
  16. Zhu, L.; Dai, J.; Bai, G.; Zhang, F. Study on thermal properties of recycled aggregate concrete and recycled concrete blocks. Constr. Build. Mater. Constr. 2015, 94, 620–628. [Google Scholar] [CrossRef]
  17. Benazzouk, A.; Douzane, O.; Mezreb, K.; Laidoudi, B.; Quéneudec, M. Thermal conductivity of cement composites containing rubber waste particles: Experimental study and modelling. Constr. Build. Mater. 2008, 22, 573–579. [Google Scholar] [CrossRef]
  18. Chung, S.Y.; AbdElrahman, M.; Sikora, P.; Rucinska, T.; Horszczaruk, E.; Stephan, D. Evaluation of the effects of crushed and expanded waste glass aggregates on the material properties of lightweight concrete using image-based approaches. Materials 2017, 10, 1354. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  19. Nagy, B.; Nehme, S.G.; Szagri, D. Thermal Properties and Modeling of Fiber Reinforced Concrete. Energy Procedia 2015, 78, 2742–2747. [Google Scholar] [CrossRef] [Green Version]
  20. Abyaneh, S.D.; Wong, H.S.; Buenfeld, N.R. Computational investigation of capillary absorption in concrete using a three-dimensional mesoscale approach. Comput. Mater. Sci. 2014, 87, 54–64. [Google Scholar] [CrossRef] [Green Version]
  21. Liu, Q.F.; Feng, G.L.; Xia, J.; Yang, J.; Li, L. Ionic transport features in concrete composites containing various shaped aggregates: A numerical study. Compos.Struct. 2018, 183, 371–380. [Google Scholar] [CrossRef] [Green Version]
  22. Mao, L.X.; Hu, Z.; Xia, J.; Feng, G.L.; Azim, I.; Yang, J.; Liu, Q.F. Multi-phase modelling of electrochemical rehabilitation for ASR and chloride affected concrete composites. Compos. Struct. 2019, 207, 176–189. [Google Scholar] [CrossRef]
  23. Abyaneh, S.D.; Wong, H.S.; Buenfeld, N.R. Modelling the diffusivity of mortar and concrete using a three-dimensional mesostructure with several aggregate shapes. Comput. Mater. Sci. 2013, 78, 63–73. [Google Scholar] [CrossRef] [Green Version]
  24. Zheng, J.J.; Zhou, X.Z.; Wu, Y.W.; Xin, J.Y. A numerical method for the chloride diffusivity in concrete with aggregate shape effect. Constr. Build. Mater. 2012, 31, 151–156. [Google Scholar] [CrossRef]
  25. Zergadło, B.; Halicka, A. Analizawłaściwościcieplnychbetonu z kruszywem z odpadówceramikisanitarnej. Bud. Archit. 2011, 9, 39–49. [Google Scholar]
  26. Jastrzębski, P.; Saługa, P. Innowacyjnemetodygromadzeniaciepła. Zesz. Nauk. Inst. Gospod. Surowcami Miner. Energią PAN 2018, 105, 225–232. [Google Scholar]
  27. Kata, D. SpiekanyAzotekGlinu o WysokimPrzewodnictwieCieplnym; Wydawnictwa AGH: Kraków, Poland, 2015. [Google Scholar]
  28. Avghad, S.N.; Keche, A.J.; Kousal, A. Thermal Energy Storage: A Review. IOSR- J. Mech. Civ. Eng. 2016, 13, 72–77. [Google Scholar]
  29. Gencel, O.; Koksal, F.; Şahin, M.; Durgun, M.Y.; Lobland, H.E.H.; Brostow, W. Modeling of thermal conductivity of concrete with vermiculite using by artificial neural networks approaches. Exp. Heat Transfer 2013, 26, 360–383. [Google Scholar] [CrossRef]
  30. Kurpinska, M.; Kułak, L. Predicting performance of lightweight concrete with granulated expanded Glass and Ash aggregate by means of using Artificial Neural Networks. Materials 2019, 12, 2002. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  31. Carlson, J.D.; Bhardwaj, R.; Phelan, P.E.; Kaloush, K.E.; Golden, J.S. Determining thermal conductivity of paving materials using cylindrical sample geometry. J. Mater. Civ. Eng. 2010, 22, 186–195. [Google Scholar] [CrossRef]
  32. Devpura, A.; Phelan, P.E.; Prasher, R.S. Size effects on the thermal conductivity of polymers laden with highly conductive filler particles. Microscale Themophysics Eng. 2010, 5, 177–189. [Google Scholar] [CrossRef]
  33. Patterson, N.; Yoon, S.; Macphee, D.E.; Imbabi, M.S. The cuboid method for measurement of thermal properties of cement-based materials using the guarded heat flow meter. Constr. Build. Mater. 2018. [CrossRef]
  34. PN-EN 206 + A1:2016-12;Concrete— equirements, Properties, Production and Compliance; Polish Committee for Standardization: Warsaw, Poland, 2016.
  35. Grimvall, G. Thermophysical Properties of Materials; North-Holland: Amsterdam, The Netherlands, 1986. [Google Scholar]
  36. Bailey, D.G. Heat Capacity of Minerals: A hands-On Introduction to Chemical Thermodynamics. In Teaching Mineralogy, Mineralogical Society of America; Mineralogical Society of America: Chantilly, VA, USA, 1997. [Google Scholar]
  37. Stempkowska, A.; Izak, P.; Mastalska-Popławska, J.; Staszewska, M. The analysis ofthermal properties of selected rock materials by thermovision methods. J. Pol. Miner. Eng. Soc. 2018, 20, 337–344. [Google Scholar]
  38. Stempkowska, A.; Gawenda, T.; Naziemiec, Z.; Adam Ostrowski, K.; Saramak, D.; Surowiak, A. Impact of the Geometrical Parameters of Dolomite Coarse Aggregate on the Thermal and Mechanic Properties of Preplaced Aggregate Concrete. Materials 2020, 186, 4358. [Google Scholar] [CrossRef] [PubMed]
  39. Rutkowska, G. Betonzwykłyjakomateriał do akumulacjiciepła w budownictwie. Architektura 2011, 10, 33–41. [Google Scholar]
  40. Mshali, M.R.; Visser, A.T. Influence of mica on unconfined compressive strength of a cement-treated weathered granite gravel. J. South Afr. Inst. Civ. Eng. 2012, 54, 71–77. [Google Scholar]
  41. Tugrul, A.; Hasdemir, S.; Yılmaz, M. The Effect of Feldspar, Mica and Clay Minerals on Compressive Strength of Mortar. In Engineering Geology for Society and Territory; Springer: Cham, Switzerland, 2015; Volume 5. [Google Scholar] [CrossRef]
  42. Taylor, H.F.W. The Chemistry of Cements; Academic Press Limited: London, UK, 1990. [Google Scholar]
  43. Kurdowski, W. ChemiaCementuiBetonu; Wydawnictwa AGH: Kraków, Poland, 2010. [Google Scholar]
  44. Gruner, M. KorozjaiOchronaBetonu; Arkady: Warszawa, Poland, 1983. [Google Scholar]
  45. Królikowski, W. TworzywaWzmocnioneiWłóknaWzmacniające; WydawnictwoNaukowo—Techniczne: Warszawa, Polland, 1988. [Google Scholar]
  46. Kalifa, P.; Chene, G.; Galle, C. High-temperature behavior of HPC with polypropylene fibers. From spalling to microstructure. Cem. Concr. Res. 2001, 31, 1487–1499. [Google Scholar] [CrossRef]
  47. Kalifa, P.; Menneteau, F.D.; Quenard, D. Spalling and pore pressure in HPC at high temperatures. Cem. Concr. Res. 2000, 30, 1915–1927. [Google Scholar] [CrossRef]
  48. Vitek, J.L. Fire resistance of concrete tunnel linings, Experimental research. In Proceedings of the 3rd Central European Congress on Concrete Engineering 2007—Innovative Materials and Technologies, Visegrad, Hungary, 17–18 September 2007. [Google Scholar]
Figure 1. Thermal capacity dependence in function of temperature.
Figure 1. Thermal capacity dependence in function of temperature.
Materials 14 00904 g001
Figure 2. Sample during the thermal imaging test.
Figure 2. Sample during the thermal imaging test.
Materials 14 00904 g002
Figure 3. Measurement of the bending strength via three-point bending.
Figure 3. Measurement of the bending strength via three-point bending.
Materials 14 00904 g003
Figure 4. Example thermal image of the temperature distribution on the surface of the tested sample.
Figure 4. Example thermal image of the temperature distribution on the surface of the tested sample.
Materials 14 00904 g004
Figure 5. Combined temperature distribution diagram on the surface of cooling samples.
Figure 5. Combined temperature distribution diagram on the surface of cooling samples.
Materials 14 00904 g005
Figure 6. Thermal analysis differential thermal analysis/differential scanning calorimetry (DTA/DSC) of sample 2.
Figure 6. Thermal analysis differential thermal analysis/differential scanning calorimetry (DTA/DSC) of sample 2.
Materials 14 00904 g006
Figure 7. Thermal analysis DTA/DSC of sample 3.
Figure 7. Thermal analysis DTA/DSC of sample 3.
Materials 14 00904 g007
Figure 8. Thermal analysis DTA/DSC of sample 5.
Figure 8. Thermal analysis DTA/DSC of sample 5.
Materials 14 00904 g008
Figure 9. SEM microphotograph and energy dispersive spectroscopy (EDS) analysis of sample 1.
Figure 9. SEM microphotograph and energy dispersive spectroscopy (EDS) analysis of sample 1.
Materials 14 00904 g009
Figure 10. SEM microphotograph and EDS analysis of sample 2.
Figure 10. SEM microphotograph and EDS analysis of sample 2.
Materials 14 00904 g010
Figure 11. SEM microphotograph and EDS analysis of sample 3.
Figure 11. SEM microphotograph and EDS analysis of sample 3.
Materials 14 00904 g011
Figure 12. SEM microphotograph and EDS analysis of sample 4.
Figure 12. SEM microphotograph and EDS analysis of sample 4.
Materials 14 00904 g012
Figure 13. SEM microphotograph and EDS analysis of sample 5.
Figure 13. SEM microphotograph and EDS analysis of sample 5.
Materials 14 00904 g013
Table 1. Concrete mix compositions used in research
Table 1. Concrete mix compositions used in research
SampleIngredient% wt
1
Concrete with sandstone aggregate enriched with glass fibres
Portland cement CEM I 52.5 R
Sand aggregate 0–2 mm
Quatrz meal 0.75
Glass fibres 12 mm
Pigment
Superplasticizer + additives
28.528
45.645
13.313
0.266
0.799
1.654
2
Concrete with silicate and refractory aggregate enriched with polypropylene fibres
High alumina cement 70
Portland cement CEM I 52.5 R
Fine silicate aggregate 0–2 mm
Refractory aggregate 0–5 mm
Polypropylene fibres 3 mm
Pigment
Superplasticizer + additives
15.1
4.9
12.0
67.4
0.141
0.304
0.100
3
Concrete with silicate and carbonate aggregates enriched with glass and polypropylene fibers
Portland cement CEM I 52.5 R
Carbonate aggregate 8–16mm
Silicate aggregate 0–4 mm
Glass fibres 12 mm
Polypropylene fibres 3 mm
Pigment
Superplasticizer + additives
31.343
47.062
6.268
0.209
0.020
1.567
2.037
4
Foam concrete with sand aggregate enriched with glass and steel fibers
Portland cement CEM I 52.5 R
Sand 0–2 mm
Glass fibres 12 mm
Steel fibres 25 mm
Superplasticizer + additives
26.725
61.824
1.158
0.677
1.242
5
Concrete with mafic agregate enriched with polypropylene and steel fibres
Portland cement CEM I 52.5 R
High alumina cement 40
Mafic fine aggregate 0.75–3 mm
Mafic aggregate 2–8 mm
Polypropylene fibres 6 and 20 mm
Steel fibres 12 mm
Pigment
Superplasticizer + additives
4.740
11.037
32.298
40.355
0.025
0.677
0.406
0.304
Table 2. Physical parameters of the tested samples.
Table 2. Physical parameters of the tested samples.
SampleMass (g)Volume (cm3)Density (g/cm3)
1447.24210.052.13
2351.52199.311.76
3372.98176.72.11
4282188.61.5
5589.33272.652.16
Table 3. Temperature of the tested samples depending on the cooling time.
Table 3. Temperature of the tested samples depending on the cooling time.
Time
(min)
Temperature (°C)
12345
0134.8131.8128.6132.1137.7
1130.7125.4119127.3124.6
2126.4121.6115.6121.7122.5
3123.5116111.7113.8118.3
4119.5110.6109.5110.4115.8
5115106.2103.6104.5111.2
6112.6102.3101100.1109.5
7108.198.596.696.7104.3
8104.494.69088103.3
9100.991.288.386.199.9
1097.886.987.880.295.2
1291.281.686.273.691.6
1485.974.679.368.587.6
1679.571.571.564.282.6
1876.567.568.856.777.2
2072.26365.653.476.9
2563.453.458.946.974
3057.247.654.34267.4
3552.843.350.338.458.4
4048.838.748.63854.6
4545.537.246.136.252.6
5040.936.445.835.848.1
Table 4. Specific heat of raw materials used to prepare samples.
Table 4. Specific heat of raw materials used to prepare samples.
Ingredientcv
(J/kg·K)
Sand800
Cement504
Water4190
Silicate aggregate1006
Mafic aggregate990
Carbonate aggregate920
Refractory aggregate1750
Glass fiber840
Polypropylene fiber1460
Steel fiber440
Table 5. The total specific heat of the tested samples.
Table 5. The total specific heat of the tested samples.
SampleΣ cv
(J/kg·K)
11017.79
2765.78
31170.03
4990.58
51120.15
Table 6. The ∆T and ∆Q values of the materials tested.
Table 6. The ∆T and ∆Q values of the materials tested.
SampleT
(K)
Q
(kJ)
193.942.72
295.425.64
382.836.13
496.326.9
589.659.11
Table 7. Volume thermal capacity of the tested materials.
Table 7. Volume thermal capacity of the tested materials.
Sampleb
(kJ/m3·K)
bmax
(MJ/m3)
12167.89203.57
21347.77128.50
32468.76204.43
41485.87143.01
52419.52216.83
Table 8. Thermal power of the tested materials.
Table 8. Thermal power of the tested materials.
SampleP (W)
114.24
28.55
312.04
48.97
519.70
Table 9. Values of the mechanical strength under bending of the tested fireplace materials.
Table 9. Values of the mechanical strength under bending of the tested fireplace materials.
Sample SymbolMaturation Time (days)
1728
Mechanical (MPa)
18.59.912.3
23.54.35
37.41013.2
42.94.14.7
51.834.8
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Stempkowska, A.; Mastalska-Popławska, J.; Izak, P.; Wójcik, Ł.; Gawenda, T.; Karbowy, M. Research on the Thermal Properties of Fireplace Concrete Materials Containing Various Mineral Aggregates Enriched by Organic and Inorganic Fibers. Materials 2021, 14, 904. https://doi.org/10.3390/ma14040904

AMA Style

Stempkowska A, Mastalska-Popławska J, Izak P, Wójcik Ł, Gawenda T, Karbowy M. Research on the Thermal Properties of Fireplace Concrete Materials Containing Various Mineral Aggregates Enriched by Organic and Inorganic Fibers. Materials. 2021; 14(4):904. https://doi.org/10.3390/ma14040904

Chicago/Turabian Style

Stempkowska, Agata, Joanna Mastalska-Popławska, Piotr Izak, Łukasz Wójcik, Tomasz Gawenda, and Marzena Karbowy. 2021. "Research on the Thermal Properties of Fireplace Concrete Materials Containing Various Mineral Aggregates Enriched by Organic and Inorganic Fibers" Materials 14, no. 4: 904. https://doi.org/10.3390/ma14040904

APA Style

Stempkowska, A., Mastalska-Popławska, J., Izak, P., Wójcik, Ł., Gawenda, T., & Karbowy, M. (2021). Research on the Thermal Properties of Fireplace Concrete Materials Containing Various Mineral Aggregates Enriched by Organic and Inorganic Fibers. Materials, 14(4), 904. https://doi.org/10.3390/ma14040904

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop