On the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator

1
Materials Safety Technology Development Division, Korea Atomic Energy Research Institute, Daejeon 34057, Republic of Korea
2
Nuclear Materials Research Group, FNC Technology Co., Ltd., Yongin 17084, Republic of Korea
*
Author to whom correspondence should be addressed.
Materials 2022, 15(23), 8471; https://doi.org/10.3390/ma15238471
Submission received: 18 October 2022 / Revised: 18 November 2022 / Accepted: 25 November 2022 / Published: 28 November 2022

Abstract

:
The corrosion behavior and integrity of steam generator (SG) tube materials have frequently been tested in solutions containing sodium hydroxide (NaOH), assuming that NaOH is a typical contaminant concentrated in the crevices of SGs in a pressurized water reactor. The purpose of this study was to investigate the adequacy of using concentrated NaOH solutions to simulate the crevice environments of SGs. The dissolution behavior of magnetite deposit flakes formed in an operating SG was tested in a 0.4 wt.% NaOH solution at 300 °C, and the thermodynamic stability of magnetite was investigated using the potential-pH diagram for an iron–water system. The magnetite deposits were rapidly dissolved in the test solution, which was supported by the fact that magnetite is thermodynamically unstable under the test condition to dissolve to dihypoferrite ions (HFeO2). These results indicate that research data obtained from concentrated NaOH solutions are not appropriate to apply to the crevice environments of SGs.

1. Introduction

In a pressurized water reactor, high-pressure steam to drive a turbine is generated by a classic shell-and-tube type steam generator (SG). Both end sides of a heat-transfer tube in the SG are leak-tight expanded in a thick tubesheet. Tube bundles are supported with horizontal and vertical plates to prevent flow-induced vibration and fretting wear of the tubing. Therefore, these manufacturing processes inevitably create numerous crevices around tubes expanded in the tubesheet and tubes supported by the tube support plates (TSPs). Typical crevice geometries around SG tubing are shown in Figure 1.
It is well known that aggressive impurity chemicals in the SG feedwater are concentrated into the narrow-heated crevices, thereby inducing corrosion damage of the SG tubing including intergranular attack, pitting, denting, and stress corrosion cracking. On the other hand, corrosion products released due to the flow-accelerated corrosion of iron-based piping materials are transported into the SGs and deposited on the surfaces of the SG materials including tubes, TSPs, and tubesheets. The SG deposits are mainly composed of magnetite (Fe3O4) that contains numerous pores [1,2,3,4,5,6,7]. As a result, chemical impurities are easily concentrated within the deposits. Therefore, impurity concentration and the resultant corrosion damage are accelerated in the crevices covered with the porous deposits [8,9,10].
SG water chemistry is controlled on the all-volatile treatment basis using a pH control agent (ammonia, ethanolamine, morpholine, etc.) and an oxygen scavenger (hydrazine) [11]. The pH of the SG feedwater is normally adjusted in the range of 9.2 to 10.0 at 25 °C to minimize flow-accelerated corrosion and the resultant transport of corrosion products to the SGs [12]. Bulk water impurities in the operation of SGs are strictly limited as follows: sodium < 5 ppb, chloride < 10 ppb, and sulfate < 10 ppb [11]. Nevertheless, the bulk water can transiently be contaminated by some sources: seawater influx due to condenser leakage, unwanted discharge from ion exchange resins, and impurity ingress during maintenance processes.
Against this background, corrosion tests for SG materials have been performed in aqueous solutions containing various contaminants to simulate corrosive crevice environments. The typical contaminants are as follows: sodium, chloride, sulfur, lead, silica, etc. [9,10,13,14,15,16]. Accordingly, the following solutions have been widely used: solutions containing sodium hydroxide (NaOH) [17,18,19,20,21,22], sodium chloride (NaCl) [23,24,25], sulfate (SO42−), sulfite (SO32−), tetrathionate (S4O62−) and thiosulfate (S2O32−) [26,27,28,29], lead oxide (PbO) [30,31,32], and silicone compounds (SiO2, Na2SiO3) [33,34,35]. Among them, NaOH solution has been frequently used to investigate the performance of SG tubing under impurity-concentrated crevice conditions. As of now, more than 180 papers have been published in journals listed in the Science Citation Index, since the 1970s. The concentration of NaOH in the test solutions was up to 50 wt.%. It should be emphasized that accelerated corrosion experiments should be relevant to the application [36]. In other words, if the water chemistry used in a corrosion test is not suitable, the test results are useless for application to SG crevice conditions. In this context, the purpose of this study was to investigate the adequacy of using concentrated NaOH solutions to simulate the crevice environments of SGs. To this end, this study examined the immersion corrosion behavior of deposit flakes taken from an operating SG in 0.4 wt.% NaOH solution at 300 °C. The thermodynamic stability of magnetite was also investigated at various NaOH concentrations.

2. Materials and Methods

The corrosion test of SG deposits was performed using deposit flakes taken from an operating nuclear SG. The deposit flakes were pulled out from the outer surfaces of SG tubes during sludge lancing after operation of fuel cycle 27 in a pressurized water reactor. The SGs of the plant are equipped with nickel-based Alloy 600 tubes (15Cr-9Fe-76Ni in wt.%) as the heat-transfer tubing and have operated under a reducing all-volatile treatment condition with a pH range of 9.0 to 9.6 since the first commercial operation. The deposits were mostly composed of magnetite and contained small amounts of trevorite (NiFe2O4), jacobsite (MnFe2O4), and metallic copper. The porosity of the deposits was measured to be approximately 9.8%. The detailed characteristics of the deposits are given elsewhere [1].
The dissolution behavior of the deposit flakes was investigated under two different water chemistry conditions listed in Table 1. The reference condition simulates a normal bulk water chemistry with a pH25°C of 9.5. The reference solution was prepared by adding a dilute NaOH solution to deionized water, resulting in a NaOH concentration of 1.075 × 10−4 wt.% and a pH of 9.5 at 25 °C. The caustic condition represents a simulated crevice environment of an SG, which contains 0.4 wt.% NaOH. As shown in Figure 2, an SG deposit flake was placed in an Alloy 600 container, of which the top end was open and the bottom sheet was pierced, thereby facilitating the interaction of the flake with the solution. The tests were conducted with the respective chemistry conditions using two separate static nickel autoclaves with a 2 L capacity. One liter of the test solution was loaded into the autoclave, de-aerated by bubbling argon gas (a purity of 99.999%) into the solution after the closure of the autoclave at a rate of 300 mL/min at room temperature (~23 °C) for 3 h and then heated to 300 °C. It was confirmed through a separate experiment before the immersion test that dissolved oxygen was removed below 10 ppb by the de-aeration process. The tests were interrupted to examine the morphology change of the flake samples after 20 and 30 days. An optical microscope (Keyence, Osaka, Japan, model VHX-5000) and a scanning electron microscope (SEM, TESCAN, Brno, Czech Republic, model LYRA3) were used to observe the morphology of the samples. SEM micrographs were taken at an accelerating voltage of 5 kV. The test solution was refreshed after each examination.

3. Results and Discussion

3.1. Dissolution Behavior of the SG Deposit Flakes

Figure 3 shows the optical images of the SG deposit flake samples exposed to the two different water chemistry conditions at 300 °C. In the reference solution, there was no change in the surface morphology of the sample up to 30 days. However, it was difficult to recognize the original shape of the deposit sample immersed in the caustic solution. In other words, the sample was rapidly dissolved and only a certain amount of the flake was left after the 30-day immersion.
The surface morphologies of the samples exposed to the solutions were further examined using SEM. The as-received deposit flakes were hard and brittle in nature. As shown in Figure 4a, the deposit flakes were typically composed of numerous magnetite particles ranging from tens of nanometers to several micrometers in size. The particles were polyhedral or roundish in shape. More detailed morphology, microstructure, and chemical composition of the deposits are given elsewhere [1]. As shown in Figure 4a,b, the size and shape of the particles of the deposit flakes did not change after exposure in the reference solution for 30 days. However, comparing Figure 4c with Figure 4a, the size of the particles was significantly decreased, and the shape tended to have more rounded edges, indicating that the deposit particles were dissolved in the caustic solution.

3.2. Thermodynamics for the Dissolution of the SG Deposit Flakes

The dissolution of the SG deposits indicates that the deposits are thermodynamically unstable in 0.4 wt.% NaOH solution. The deposits can be assumed to be magnetite because they are mostly composed of magnetite [1]. Therefore, the stability of the magnetite deposits can be inferred using a potential-pH diagram. Figure 5 shows the potential-pH equilibrium diagram for an iron–water system at 300 °C [37]. pH values at 300 °C in various environments were calculated using the MULTEQ code (Version 4.2.0) and presented in the diagram. Typical operating pH values of 9.2 to 10.0 at 25 °C were in the pH range of 6.0 to 6.5 at 300 °C, which are denoted by the green rectangle. pH300°C values with NaOH concentration were calculated to be 9.5 at 0.1 wt.% NaOH solution, 9.8 at 0.4 wt.% NaOH solution, and 10.4 at 10 wt.% NaOH solution, which are presented by the dotted vertical lines. It can be deduced that the SG magnetite deposits used in this study were formed within the stable domain of magnetite, which is shown in the red box. Similarly, the lack of dissolution of the deposit flakes immersed in the reference solution indicates that the deposits are still located in the stable area of magnetite during the immersion tests. Therefore, based on the immersion test result and the diagram, the equilibrium potentials of magnetite are thought to be situated close to the hydrogen line in the typical operating pH25°C ranges of 9.2 to 10.0.
Let us consider the following electrochemical reaction:
3HFeO2 + H+ = Fe3O4 + 2H2O + 2e
The equilibrium of this reaction is expressed by line ① in Figure 5. The standard equilibrium potential ( E o ) of Reaction (1) at 25 °C is described as follows:
E o = μ F e 3 O 4 o + 2 μ H 2 O o 3 μ H F e O 2 o   2 F
where μ i o is the standard chemical potential of the i substance, and F is the Faraday constant (96,485 Cmol−1). Based on the following values of the standard chemical potentials ( μ F e 3 O 4   o = −242,400 cal, μ H 2 O o = −56,690 cal, and μ H F e O 2 o = −90,627 cal) [38], E o is calculated to be −1.819 VSHE from Equation (2). Now, the equilibrium potential ( E ) of Reaction (1) at 300 °C can be calculated using the following Nernst equation:
E = E o + 2.3 R T 2 F log ( a F e 3 O 4 ) a H 2 O 2 a H F e O 2 3 a H +  
E = 1.819 + 0.0568 pH 0.1706 log a H F e O 2  
where R is the gas constant (1.987 calmol−1K−1), T is the absolute temperature (K), and a i is the activity of the i substance. For the 0.4 wt.% NaOH solution, since magnetite is dissolved, the potentials at which the HFeO2 species (dihypoferrite ion) is stable are in the range of −1.239 to −1.395 VSHE, shown in Figure 5. From Equation (4), these values correspond to an a H F e O 2 of 0.73 to 6.0. Consequently, these calculations provide evidence that magnetite is thermodynamically unstable in 0.4 wt.% NaOH solution, leading to a dissolution to HFeO2 ions. This is consistent with the immersion test result showing a rapid dissolution of magnetite in 0.4 wt.% NaOH solution. In a similar manner, we can predict that magnetite is no more stable in a caustic solution containing NaOH over 0.1 wt.% under the reducing environments of SGs.
Based on this work, if caustic environments are formed in heated crevices covered with magnetite deposits and within porous deposits on the tubes, the deposits would be dissolved. In contrast, the deposit inventory of SGs increases during plant operation and is thus removed by sludge lancing and chemical cleaning [39,40,41]. The deposit flakes used in the dissolution test were also formed in an operating SG. Therefore, the results obtained in this work indicate that concentrated NaOH solutions are not relevant to the real crevice environments of SGs.
Corio showed for the first time in the world that intergranular corrosion and stress corrosion cracking of the Alloy 600 SG tube material can occur in deoxygenated pure water [42], while Copson failed to reproduce such attack [43,44]. The essential reason is that Copson used boiling MgCl2 solutions as accelerated test conditions, which are not relevant to nuclear environments. Similarly, test results in concentrated NaOH solutions may be misleading and not suitable for evaluating the corrosion behavior of SG tubing materials. Consequently, the test parameters should be chosen to closely simulate the conditions encountered in the SG crevices during operation.

4. Conclusions

This study investigated the stability of magnetite deposits through immersion experiments in normal and caustic solutions and thermodynamic consideration for an iron–water system at 300 °C. The magnetite deposits formed in a real SG were rapidly dissolved in 0.4 wt.% NaOH solution. This result is consistent with the thermodynamic calculation that magnetite is not stable in a solution containing NaOH over 0.1 wt.% dissolving magnetite to dihypoferrite ions. These results indicate that concentrated NaOH conditions are not applicable in simulating the real crevice environments of SGs. Therefore, the research results from tests conducted in concentrated NaOH solutions may be misleading and not suitable for evaluating the corrosion behavior of SG tubing materials.

Author Contributions

Conceptualization, D.-H.H.; methodology, D.-H.H.; software, J.H.; formal analysis, G.-D.S.; investigation, G.-D.S.; resources, S.-H.J.; data curation, G.-D.S. and S.-H.J.; writing—original draft preparation, D.-H.H.; writing—review and editing, D.-H.H. and G.-D.S.; visualization, G.-D.S. and J.H.; supervision, D.-H.H.; project administration, D.-H.H.; funding acquisition, D.-H.H. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by the National Research Foundation (NRF) grant funded by the government of the Republic of Korea (grant numbers: NRF-2017M2A8A4015159; RS-2022-00143316).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data are not publicly available due to legal or ethical reasons.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Jeon, S.-H.; Hong, S.; Kwon, H.-C.; Hur, D.H. Characteristics of steam generator tube deposits in an operating pressurized water reactor. J. Nucl. Mater. 2018, 507, 371–380. [Google Scholar] [CrossRef]
  2. Tapping, R.L.; Turner, C.W.; Thompson, R. Steam Generator Deposits—A Detailed Analysis and Some Inferences. Corrosion 1991, 47, 489–495. [Google Scholar] [CrossRef]
  3. Manahan, M.P. Mechanical behaviour of magnetite from the Oconee-2 and TMI-1 steam generators using miniaturized specimen technology. J. Mater. Sci. 1990, 25, 3415–3423. [Google Scholar] [CrossRef]
  4. Gusev, B.A.; Efimov, A.A.; Aleshin, A.M.; Semenov, V.G.; Panchuk, V.V.; Martynov, V.V.; Maksimova, A.N. Morphology and Phase Composition of Oxide Films and Corrosion Product Deposits in the Steam Generator of a BN-800 Reactor Unit. Therm. Eng. 2022, 69, 227–233. [Google Scholar] [CrossRef]
  5. Beal, K.; Million-Picallion, L.; Delaunay, S.; Berger, G.; Lefèvre, G. Insights into the formation mechanism of hard sludge on the secondary side of PWR steam generators. Nucl. Mater. Energy 2022, 31, 101197. [Google Scholar] [CrossRef]
  6. Yang, G.; Pointeau, V.; Tevissen, E.; Chagnes, A. A review on clogging of recirculating steam generators in Pressurized-Water Reactors. Prog. Nucl. Energy 2017, 97, 182–196. [Google Scholar] [CrossRef] [Green Version]
  7. Prusek, T.; Moleiro, E.; Oukacine, F.; Adobes, A.; Jaeger, M.; Grandotto, M. Deposit models for tube support plate flow blockage in Steam Generators. Nucl. Eng. Des. 2013, 262, 418–428. [Google Scholar] [CrossRef]
  8. Lu, B.T.; Luo, J.L.; Lu, Y.C. A Mechanistic Study on Lead-Induced Passivity-Degradation of Nickel-Based Alloy. J. Electrochem. Soc. 2007, 154, C379–C389. [Google Scholar] [CrossRef]
  9. Staehle, R.W.; Gorman, J.A. Quantitative Assessment of Submodes of Stress Corrosion Cracking on the Secondary Side of Steam Generator Tubing in Pressurized Water Reactors: Part 3. Corrosion 2004, 60, 115–180. [Google Scholar] [CrossRef]
  10. Boursier, J.B.; Dupin, M.; Sosset, P.; Rouillon, Y. Secondary side corrosion of French PWR steam generator tubing: Contribution of surface analyses to the understanding of the degradation process. In Proceedings of the 9th International Symposium on Environmental Degradation of Materials in Nuclear Power Systems—Water Reactors, Boston, MA, USA, 18–22 August 1999; TMS: Newport Beach, CA, USA, 1999; pp. 555–563. [Google Scholar]
  11. Fruzzetti, K. Pressurized Water Reactor Secondary Water Chemistry Guidelines–Revision 8; TR–3002010645; Electric Power Research Institute: Palo Alto, CA, USA, 2017. [Google Scholar]
  12. Marks, C. Steam Generator Management Program: Effects of Different pH Control Agents on Pressurized Water Reactor Plant Systems and Components; TR–1019042; Electric Power Research Institute: Palo Alto, CA, USA, 2009. [Google Scholar]
  13. Hur, D.H.; Lee, D.H.; Choi, M.S.; Song, M.H.; Han, J.H. Root causes of intergranular attack in an operating nuclear steam generator tube. J. Nucl. Mater. 2008, 375, 382–387. [Google Scholar] [CrossRef]
  14. Hur, D.H.; Choi, M.S.; Lee, D.H.; Song, M.H.; Han, J.H. Pitting Corrosion and its Countermeasures for Pressurized Water Reactor Steam Generator Tubes. Corrosion 2006, 62, 905–910. [Google Scholar] [CrossRef]
  15. Thomas, L.; Johnson, B.; Bruemmer, S. Sulfur at crack tips in Alloy 600 service samples. In Workshop of Effects of Pb and S on the Performance of Secondary Side Tubing of Steam Generators in PWRs; Argon National Laboratory: Lemont, IL, USA, 2005. [Google Scholar]
  16. King, P.K.; Gonzalez, F.; Brown, J. Stress corrosion experience in steam generators at Bruce NGS. In Proceedings of the Sixth In-ternational Symposium on Environmental Degradation of Materials in Nuclear Power Systems—Water Reactors, San Diego, CA, USA, 1–5 August 1993; TMS: San Diego, CA, USA, 1993; pp. 233–240. [Google Scholar]
  17. Cels, J.R. Stress Corrosion Cracking of Stainless Steel and Nickel Alloys at Controlled Potentials in 10% Caustic Soda Solutions at 550 °F. J. Electrochem. Soc. 1976, 123, 1152–1156. [Google Scholar] [CrossRef]
  18. Theus, G.J. Relationship Between Acid Intergranular Corrosion and Caustic Stress Corrosion Cracking of Alloy 600. Corrosion 1977, 33, 20–26. [Google Scholar] [CrossRef]
  19. Wu, B.; Ming, H.; Zhang, Z.; Meng, F.; He, G.; Wang, J.; Han, E.-H. Microstructure and stress corrosion cracking behavior of Alloy 690TT steam generator tubes with internal bulge defect. J. Nucl. Mater. 2022, 563, 153629. [Google Scholar] [CrossRef]
  20. Bharasi, N.S.; Toppo, A.; Paul, V.T.; George, R.P.; Philip, J. Studies on the Susceptibility of Modified 9Cr-1Mo Steel to Stress Corrosion Cracking in Sodium Hydroxide Using Slow Strain Rate Testing Technique. J. Mater. Eng. Perform. 2020, 29, 2172–2184. [Google Scholar] [CrossRef]
  21. Meng, F.; Han, E.-H.; Wang, J.; Zhang, Z.; Ke, W. Localized corrosion behavior of scratches on nickel-base Alloy 690TT. Electrochim. Acta 2011, 56, 1781–1785. [Google Scholar] [CrossRef]
  22. Hur, D.H.; Kim, J.S.; Baek, J.S.; Kim, J.G. Inhibition of Stress Corrosion Cracking of Alloy 600 in 10% Sodium Hydroxide Solution at 315 °C. Corrosion 2002, 58, 1031–1038. [Google Scholar] [CrossRef]
  23. Chen, Y.; Chou, L.; Shih, H. Factors affecting the electrochemical behavior and stress corrosion cracking of Alloy 690 in chloride environments. Mater. Chem. Phys. 2006, 97, 37–49. [Google Scholar] [CrossRef]
  24. Li, J.; Yang, B.; Lu, Y.; Xin, L.; Wang, Z.; Shoji, T. The effect of normal force on fretting corrosion behavior of Inconel 690 in 3.5% sodium chloride. Mater. Charact. 2017, 131, 224–233. [Google Scholar] [CrossRef]
  25. Wang, W.; Zhang, M.; Cheng, K.; Wang, B.; Tian, R. A coupled model of corrosion of the steam generator heat transfer tube. Nucl. Eng. Des. 2022, 396, 111895. [Google Scholar] [CrossRef]
  26. Persaud, S.; Long, F.; Korinek, A.; Smith, J. High resolution characterization of sulfur-assisted degradation in alloy 800. Corros. Sci. 2018, 140, 122–133. [Google Scholar] [CrossRef]
  27. Zhang, W.; Carcea, A.G.; Newman, R.C. Pitting of steam-generator tubing alloys in solutions containing thiosulfate and sulfate or chloride. Faraday Discuss. 2015, 180, 233–249. [Google Scholar] [CrossRef] [PubMed]
  28. Xia, D.-H.; Wang, J.; Qin, Z.; Gao, Z.; Wu, Z.; Wang, J.; Yang, L.; Hu, W.; Luo, J.-H. Sulfur induced corrosion (SIC) mechanism of steam generator (SG) tubing at micro scale: A critical review. Mater. Chem. Phys. 2019, 233, 133–140. [Google Scholar] [CrossRef]
  29. Fang, Z.; Shaehle, R.W. Effects of the valence of sulfur on passivation of Alloys 600, 690, and 800 at 25 °C and 95 °C. Corrosion 1999, 55, 355–379. [Google Scholar] [CrossRef]
  30. Bojinov, M.; Jäppinen, E.; Saario, T.; Sipilä, K.; Toivonen, A. Effect of lead and applied potential on corrosion of carbon steel in steam generator crevice solutions. Corros. Sci. 2019, 159, 108117. [Google Scholar] [CrossRef]
  31. Lu, B.; Luo, J.; Lu, Y. Passivity degradation of nuclear steam generator tubing alloy induced by Pb contamination at high temperature. J. Nucl. Mater. 2012, 429, 305–314. [Google Scholar] [CrossRef]
  32. Hur, D.H.; Choi, W.-I.; Song, G.D.; Jeon, S.-H.; Lim, S. Mechanistic insights into lead-accelerated stress corrosion cracking of Alloy 600. Corros. Sci. 2018, 145, 109–118. [Google Scholar] [CrossRef]
  33. Xie, Y.; Zhang, J. Corrosion and deposition on the secondary circuit of steam generators. J. Nucl. Sci. Technol. 2016, 53, 1455–1466. [Google Scholar] [CrossRef] [Green Version]
  34. Navas, M.; Gomez-Briceno, D.; Garcia-Mazario, M.; McIlree, A.R. Effect of silicon compounds on stress corrosion cracking pf Alloy 600 in caustic solutions. Corrosion 1999, 55, 674–685. [Google Scholar] [CrossRef]
  35. Yang, W.; Lu, Z.; Huang, D.; Kong, D.; Zhao, G.; Congleton, J. Caustic stress corrosion cracking of nickel-rich, chromium-bearing alloys. Corros. Sci. 2001, 43, 963–977. [Google Scholar] [CrossRef]
  36. Staehle, R.W. Historical views on stress corrosion cracking of nickel-based alloys: The Coriou effect. In Stress Corrosion Cracking of Nickel-Based Alloys in Water-Cooled Nuclear Reactors; Feron, D., Staehle, R.W., Eds.; Elsevier: Duxford, UK, 2016; pp. 3–131. [Google Scholar]
  37. Chen, C.M.; Aral, K.; Theus, G.J. Computer-Calculated Potential pH Diagrams to 300 °C; NP–3137; Electric Power Research Institute: Palo Alto, CA, USA, 1983; Volume 1. [Google Scholar]
  38. Pourbaix, M. Atlas of Electrochemical Equilibria in Aqueous Solutions; NACE: Houston, TX, USA, 1974. [Google Scholar]
  39. Varrin, R.D., Jr. Deposit accumulation in PWR steam generator. In Steam Generator for Nuclear Power Plants; Elsevier: Duxford, UK, 2017; pp. 323–363. [Google Scholar]
  40. Wolfe, R. Steam Generator Management Program: Steam Generator Deposit Removal Strategies Sourcebook; TR-30020050902015; EPRI: Palo Alto, CA, USA, 2015. [Google Scholar]
  41. Hur, D.H.; Choi, M.S.; Chung, H.S.; Kim, U.C. Optimum EDTA solvent chemistry for iron oxide removal at 150 °C. J. Nucl. Mater. 2002, 305, 220–223. [Google Scholar] [CrossRef]
  42. Coriou, H.; Grall, L.; Le Gall Vettier, S. Corrosion Fissurante Sous Contrainte de l’Inconel dans l’Eau à Haute Température; Report CEA no. 1521; CEA: Grenoble, France, 1960. [Google Scholar]
  43. Copson, H.R.; Cheng, C.F. Some case histories of stress corrosion cracking of austenitic stainless steels associated with chlorides. Corrosion 1957, 13, 397t–404t. [Google Scholar]
  44. Copson, H.R. Effect of composition on stress corrosion cracking of some alloys containing nickel. In Physical Metallurgy of Stress Corrosion Fracture; Rhodin, T.N., Ed.; Interscience: New York, NY, USA, 1959; pp. 247–272. [Google Scholar]
Figure 1. Typical crevice geometries around SG tubing at: (a) top of tubesheet, (b) broached quatrefoil-type TSP and (c) egg crate-type TSP. Crevices between tubing and TSP were denoted by the dotted red circles.
Figure 1. Typical crevice geometries around SG tubing at: (a) top of tubesheet, (b) broached quatrefoil-type TSP and (c) egg crate-type TSP. Crevices between tubing and TSP were denoted by the dotted red circles.
Materials 15 08471 g001
Figure 2. A schematic of an apparatus used for the dissolution test of SG deposit flakes.
Figure 2. A schematic of an apparatus used for the dissolution test of SG deposit flakes.
Materials 15 08471 g002
Figure 3. Optical micrographs showing the change in the morphology of the SG deposit flake samples exposed to the two different water chemistry conditions at 300 °C.
Figure 3. Optical micrographs showing the change in the morphology of the SG deposit flake samples exposed to the two different water chemistry conditions at 300 °C.
Materials 15 08471 g003
Figure 4. SEM micrographs showing the surface morphology of the SG deposit samples exposed to the two different water chemistry conditions at 300 °C for 30 days: (a) as-received, (b) immersed in the reference solution for 30 days, and (c) immersed in the 0.4 wt.% NaOH solution for 30 days.
Figure 4. SEM micrographs showing the surface morphology of the SG deposit samples exposed to the two different water chemistry conditions at 300 °C for 30 days: (a) as-received, (b) immersed in the reference solution for 30 days, and (c) immersed in the 0.4 wt.% NaOH solution for 30 days.
Materials 15 08471 g004
Figure 5. Potential-pH diagram for the iron–water system at 300 °C [37]. pH values at 300 °C in various environments were calculated using the MULTEQ code (Version 4.2.0) and superimposed in the diagram. Lines ⓐ and ⓑ represent respectively the reduction equilibrium of water according to the reaction H2 = 2H+ + 2e and the oxidation equilibrium of water according to the reaction 2H2O = O2 + 4H+ + 4e at a hydrogen or oxygen pressure of 1 atm. Line ① expresses the equilibrium of Reaction (1), 3HFeO2 + H+ = Fe3O4 + 2H2O + 2e.
Figure 5. Potential-pH diagram for the iron–water system at 300 °C [37]. pH values at 300 °C in various environments were calculated using the MULTEQ code (Version 4.2.0) and superimposed in the diagram. Lines ⓐ and ⓑ represent respectively the reduction equilibrium of water according to the reaction H2 = 2H+ + 2e and the oxidation equilibrium of water according to the reaction 2H2O = O2 + 4H+ + 4e at a hydrogen or oxygen pressure of 1 atm. Line ① expresses the equilibrium of Reaction (1), 3HFeO2 + H+ = Fe3O4 + 2H2O + 2e.
Materials 15 08471 g005
Table 1. Experimental conditions for the magnetite dissolution tests.
Table 1. Experimental conditions for the magnetite dissolution tests.
Test ConditionNaOH Concentration (wt.%)pH at 25 °CTemperature (°C)Test Duration (Day)
Reference condition1.075 × 10−49.530020, 30
Caustic condition0.40013.1
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hur, D.-H.; Song, G.-D.; Han, J.; Jeon, S.-H. On the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator. Materials 2022, 15, 8471. https://doi.org/10.3390/ma15238471

AMA Style

Hur D-H, Song G-D, Han J, Jeon S-H. On the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator. Materials. 2022; 15(23):8471. https://doi.org/10.3390/ma15238471

Chicago/Turabian Style

Hur, Do-Haeng, Geun-Dong Song, Jeoh Han, and Soon-Hyeok Jeon. 2022. "On the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator" Materials 15, no. 23: 8471. https://doi.org/10.3390/ma15238471

APA Style

Hur, D. -H., Song, G. -D., Han, J., & Jeon, S. -H. (2022). On the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator. Materials, 15(23), 8471. https://doi.org/10.3390/ma15238471

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop