1. Introduction
Fossil fuel consumption still significantly contributes to energy demand worldwide, so pollution and global warming have become critical problems [
1]. At the same time, from 2003 to 2030, worldwide energy consumption is expected to grow by 71% [
2]. Therefore, researchers try to address this issue using renewable energy sources, which may offer a solution. Solar thermal power is one of the valuable alternatives for reducing fossil fuel use, reducing greenhouse gases, and satisfying human needs. The concentrated solar power (CSP) technology is classified as line focus or point focus based on the receiving mechanism. The line focus systems include linear Fresnel reflectors and the parabolic trough, while the point focus systems include the parabolic dish, solar tower, and beam-down central receivers [
3,
4].
The most often applied technique in solar plants to produce electricity and in industrial and thermal processes is the parabolic trough collector (PTC) [
5,
6]. The concentrator and the receiver tube are significant components of the solar field. The reflector surface of the concentrator reflects solar rays onto the receiving tube, which converts solar power into heat transmitted to the heat transfer fluid (HTF), such as air, water, or oil [
7]. The receiver comprises a selective-coated metallic tube to enhance the absorption of solar irradiance. In addition, the entire tube is enveloped with a vacuumed glass tube with an anti-reflective coating to minimize heat loss by convection [
8]. The most critical component of the PTC is the receiver tube, whose performance directly reflects the PTC thermal efficiency. The higher surface temperature of the receiver tube is the major problem that leads to uneven temperature distribution over the receiver. Thus, thermal stresses and losses of the receiver tube increase [
9]. Therefore, the thermal efficiency decreases. Because of this, researchers have investigated ways to boost the heat transfer rate within the receiver to improve the PTC thermal performance.
Three techniques enhance heat transfer: passive, active, and compound [
10]. The first technique is the passive method that does not consume energy, and the heat transfer rate can be augmented by inserting various inserts inside the receiver tube with a particular engineering design or modifying the entire receiver tube surface. The second technique is the active method, such as surface vibration and magnetic fields, which requires external energy to change the path of HTF to improve the heat transfer rate. Finally, the third technique is the compound method, which combines active and passive methods [
11,
12]. Low cost and simplicity are why different inserts inside the receiver tube make it the most common ordinary technique to improve heat transfer rate [
13].
Using inserts inside the receiver tube augments the velocity fluctuation by forcing the flow beside the tube wall to mix within the flow at core regions [
7], enhancing the heat transfer coefficient. Such enhancement reduces thermal losses of the receiver tube and temperature gradient, leading to enhanced thermal efficiency [
11], while the significant penalty increases the cost of pumping power through the pressure drop increase [
14]. Twisted tape, wire coils, porous inserts, fins, cylindrical/rods, rings, and other insert configurations represent the most common inserts [
15]. Twisted tapes are the most often used insert to increase the swirling of the HTF flow to boost the thermal performance [
16] and have been investigated in studies [
17,
18,
19,
20,
21,
22,
23,
24], as introduced in the following paragraphs.
Waghole and Shrivastva [
17] assessed the influence of twisted tape within a PTC receiver with twisted ratios of 0.577, 1, and 1.732. Water and silver nanofluid were selected as HTFs under Re numbers (500–6000). Their results showed a rise in thermal efficiency, friction factor, and Nu number of 135–205%, 1–1.75 times, and 1.25–2.1 times, respectively, higher than expected by the conventional receiver. Furthermore, the water friction factor and heat transfer coefficient are lower than silver nanofluid of 0–0.1% volume concentration.
Nakhchi et al. [
19] experimentally tested the thermal performance within a pipe with twisted tape inserts with double-cut. Water is chosen as the HTF under the Re numbers range (5000–15,000). The friction factors and Nusselt numbers were increased up to 489% and 177.4%, respectively, for pipes fitted with twisted tapes with a cut ratio of 0.90, compared to the typical tube.
Arunachala [
20] experimentally analyzed the PTC performance when equipped with twisted tape and using SYLTHERM 800 as an HTF under Re numbers range of 544–1742 and the twisting ratio of 5.2, 4.1, and 2.7; then, they compared the results with an analytical model. Results showed that, at a minimum twisted ratio of 2.7, the maximum thermal efficiency of 40% is achieved, compared to 19.1% for a plain tube, while the thermo-hydraulic efficiency was decreased to 39.7% because of the increase in pressure drop.
Hosseinalipour et al. [
21] numerically investigated decreasing temperature differences within a PTC receiver using a twisted tape insert. The investigation considered superheated steam as HTF with a Re number range (10
4–9.79 × 10
5) and used different twist ratios (2.5, 5, and 10) and various clearance ratios (0, 0.2, 0.3, 0.4, and 1). The results revealed friction factors and Nu number increases of 1.8–4.1 and 1.0–1.7, respectively. Moreover, the temperature differential over the circumference was reduced by 10–45%.
Elton and Arunachala [
22] developed a correlation for the Nu number with twisted tape presence and absence. In addition, they used Soltrace to simulate non-uniform solar radiation. THERMINOL VP-1 was considered HTF and a range of Re numbers varying between (2300–2500). They found that the error in the developed correlations for standard and modified tubes lies within a range (±19% and ±20%), respectively.
Ghadirijafarbeigloo et al. [
23] numerically investigated twisted louvered tapes and compared the findings with typically twisted tape inserts at various twisting ratios of 2.67, 4, and 5.33. BEHRAN thermal oil was applied as an HTF. In their study, the Re number range was (5000–25,000). They observed that twisted louvered tape had better thermal performance than standard twisted tape. A 210% and 150% increase in friction factor and Nu number was also found when the twisted louvered tape was used.
Song et al. [
24] numerically studied using a helical insert and its impact on the PTC receiver thermal performance. First, they employed the Monte Carlo ray-tracing (MCRT) method to model the heat flux distribution over the receiver wall. Next, DOWTHERM-A was considered an HTF within a range of Re number (10,000–75,000) and inlet temperature (373–640 K). They found that at rates of mass flow of 0.11 and 0.6 kg/s, the heat losses were reduced by six and three times, fitting the helical insert. Moreover, a helical screw insert led to a pressure drop increase of 23 times.
Shashank and Sarviya [
18] experimentally and numerically investigated the influence of double and single helical inserts with the various twisted ratios of 1.5, 2.5, and 3 inside tubes. They selected water as an HTF with different Re numbers (4000–16,000). They observed that the double-helical insert’s Nu number and friction factor were higher than the single helical insert. Moreover, at a low twisted ratio, the maximum enhancement of Nu number was 112% for a double helical insert compared to an empty tube with an average friction factor of 9.1. Finally, the optimum value of entropy production number was achieved for double helical insert compared to single helical insert.
Another method to improve the thermal performance is rotating twisted tapes within the tube. This method was analyzed experimentally by Abdullah et al. [
25]. The different twisted tape ratios and variable operating rotational speeds, under constant heat flux with air as HTF and three Re numbers 8000, 10,000, and 13,000. They observed a thermal enhancement for tubes with twisted rotational tape than tubes with fixed insert. Furthermore, the higher twisted tape rotational speed and lower twisted ratio demonstrated improved thermal performance with a higher friction factor.
Cong et al. [
26] experimentally studied the flow characteristic and thermal performance of a tube with a stationary twisted tape and a rotating one at 4 RPM with TiO
2-water nanofluid as an HTF. In addition, different Re numbers from 600 to 7000 and different mass fractions of nanoparticles of 0.1%, 0.3%, and 0.5% were studied. They observed that using the applied nanofluid with rotating twisted tape improved the thermal performance by 53.1–101.6%. Furthermore, the exergy efficiency of the stationary twisted tape was increased compared to the plain tube case under similar pumping power. On the other hand, it can be reduced by using the combination of nanofluids and rotating twisted tape.
Pavan et al. [
27] investigated experimentally using rotating twisted tape of twisted ratio 2.37 within a tube. Under constant heat flux affecting the tube, water-CuO nanofluid of 0.2% volume concentration was used as HTF for different twisted tape rotational speeds and flow rates. It was concluded that, at a higher rotational speed of 300 RPM, the highest increase in heat transfer coefficient was 347% while using rotating twisted tape and nanofluid together, compared with plain tube, but the friction factor was increased 3.3 times. Other researchers used different types of inserts or compared them to increase the heat transfer performance.
Promvonge [
28] experimentally studied thermal performance enhancement in tubes supplied with twisted tapes and wire coils. The applied HTF was the air with Re numbers (3000–18,000) under constant heat flux. The experiment included wire coils with different pitch ratios and twisted tapes with various twist ratios. They observed a double rise in heat transfer when using twisted tapes with wire coils compared to twisted tape or wire coils. They also observed that using wire coils and twisted tapes with a lower twist ratio and pitch could enhance thermal performance.
Varun et al. [
29] compared the PTC performance with a wire matrix and twisted tape. The variable solar irradiance was simulated using the SOLTRACE software program. Two twisted tapes were presented with twisted ratios of 3.37 and 7.86, while three different configurations of wire matrices were presented. The selected HTF was SYNTHETIC oil under the Re number range of 1200–8200 and varying irradiation from 450 to 800 W/m
2. The experimental work showed that the augmentation in thermal efficiency for both twisted tape of 3.37 and medium dense wire matrix were 15.5% and 55.5%, respectively, with a comparable rise in pressure drop of 242% and 3602%, respectively. Regarding performance evaluation criterion analysis, the twisted tape of 3.37 is higher, whereas, in thermo-hydraulic analysis, the medium dense wire matrix is higher.
Other inserts were used to enhance heat transfer; Chakraborty et al. [
30] utilized a helical coil within the receiver of a PTC. They simulated the cases using the ANSYS software for pure water mass flow rates (0.016–0.033 kg/s). The exergy and thermal efficiency were increased by 2.4–3.3% and 10–16%, respectively, when helical coils were inserted within the receiver, despite the increased pumping power. Zhao et al. [
31] experimentally studied using pin fines within the PTC receiver tube, with air as an HTF for Re number range of 40,000–60,000. It can be concluded from the obtained results that PTC fitted with pin fines enhanced both exergy and energy efficiency by 2.55–4.29% and 10.4–14.5% in comparison with the plain receiver, while the pressure losses were increased about 10–20 times.
The use of metal foam within a PTC receiver was examined experimentally by Jamal-Abad et al. [
32] using water as HTF at various Re numbers ranging from 750 to 2000. Results illustrated that using the receiver with metal foam resulted in Nu number and thermal efficiency increase by 1.01–1.80 and 1.03 to 1.08, respectively. Furthermore, the friction factor was intensified. The overall loss coefficient was reduced, which boosted the PTC thermal efficiency. The current study investigates the effect of rotating helical shaft within a PTC receiver using outdoor experimental work with water as HTF. The experimental work is performed for different shaft rotational speeds and flow rates. According to the literature, using a rotating helical shaft inside the PTC receiver as an enhanced insert has not been investigated before. Three cases are compared and studied: a PTC without insert, a PTC with the stationary helical shaft, and a PTC with the rotating helical shaft, to determine the optimum case with better heat transfer performance with a low penalty on pressure drop. The primary criteria for evaluating the examined cases depend on fluid flow, heat transfer, and performance parameters. Finally, an economic analysis is carried out to specify the benefits of the proposed systems from an economic point of view.
3. Results and Discussion
The experimental runs were performed for three cases: (1) plain receiver tube (without insert), (2) receiver with stationary helical shaft (SHS) insert, and (3) receiver with helical shaft (RHS) insert rotating with different rotational speeds of 4 RPM (RHS1), 11 RPM (RHS2), and 21 RPM (RHS3). All cases were tested at HTF flow rates of 0.5, 1.0, 1.5, 2.0, and 2.5 LPM. The data were continuously recorded every 15 min. A nomenclature summary of the tested cases is listed in
Table 5.
The variation of Re with flow rate is presented in
Figure 8. It can be noted that the Re rises with increasing the flow rate for all cases due to the axial velocity increase with the flow rate, while at the same flow rate, the axial velocity increased in the RHS cases more than in the SHS case as the axial velocity increased with the helical shaft rotation.
Figure 9 shows the average heat transfer coefficient for all the examined cases of the PTC, which clearly shows that increasing the value of the average heat transfer coefficient with increasing the flow rate, which may be explained because more flow disturbance is created along the tube walls when the flow rate increases. Intense swirls enhance the fluid mixing between the core and near the wall regions and consequently enhance the average heat transfer coefficient by increasing the flow rate. In the cases of SHS and RHS and at a constant HTF flow rate, the helical shaft increases the intensity of swirl flow and resulting in higher contact surface area between the receiver and HTF, leading to an increase in the useful heat gain and consequently enhancing the average heat transfer coefficient with introducing SHS and RHS.
The variation of the Nu number corresponding to the average heat transfer coefficient in
Figure 9 is shown in
Figure 10a. The Nu number ratio with flow rate variation is illustrated in
Figure 10b. The higher Nu number ratio is achieved at 1 LPM compared to the other flow rates, and it achieves a maximum of 2.42 for the case of RSHS3. Furthermore, the Nu number ratio decreases with the rise of flow rate from 1.5 LPM to 2.5 LPM for all cases, while at 0.5 LPM, the Nu number ratio reaches a higher value of 2.17 for the case of RSHS3 and reaches a lower value of 1.62 for the case of SHS.
The thermal efficiencies of all tested cases are shown in
Figure 11. It can be noted that the instantaneous thermal efficiency varies with the experiment time over the day due to the rapid incident solar radiation variation. However, the thermal efficiency slightly varies when inserted the helical shaft inside the receiver tube since the helical shaft can compensate for the incident solar radiation variations over the daytime. Moreover,
Figure 11a to
Figure 11e indicate that increasing the helical shaft insert’s rotation speed results in higher and more stabilized instantaneous thermal efficiency over the daytime. This result may be attributed to improved mixing, more intense secondary flow, and higher thermal boundary layer disruption due to shaft rotation. As a consequence, the convective heat transfer is improved.
Figure 12 shows temperature differences at a different flow rate for all cases. As the flow rate decreases from 2.5 to 0.5 LPM, the temperature difference increases, as stated in [
55]. The reason is that, at the low flow rate, the HTF has a long time to increase its temperature along the receiver tube, so the temperature difference has a higher value. On the contrary, the HTF does not have enough time to increase its temperature at a high flow rate, so the temperature difference has a lower value.
Compared to a plain tube, the temperature differential is enhanced by using an insert within the receiver at a constant HTF flow rate. Furthermore, due to expanding the contact surface area for HTF with the shaft, the convective heat transfer rate is enhanced, and higher outlet temperature is observed, consequently increasing temperature difference. In addition, when the helical shaft rotates, it causes more intense secondary flow, more disturbance of the thermal boundary layer, and improved mixing. Consequently, the convective heat transfer rate and outlet temperature increase the temperature difference.
In addition, from
Figure 13a, it can be observed that the increase in the HTF flow rate boosts the instantaneous thermal efficiency. These observed results are not limited to the instant thermal efficiency. However, they extend to average daily thermal efficiencies, as illustrated in
Figure 13a. The thermal efficiency increase with increasing the flow rate is compatible with what was stated in [
52,
56] due to higher confrontation between the HTF particles and higher turbulence and, as a result, augmented thermal performance and efficiency. In the cases of RHS1, RHS2, and RHS3, the rotating helical shaft amplifies the intensity of swirl flow and enhances thermal efficiency compared to SHS. The efficiency of PTC for WIR, SHS, RHS1, RHS2, and RHS3 varies from 19% to 60.3%, 24.51% to 63.82%, 25.9% to 65.02%, 27.1% to 66.9%, and 27.9% to 69.25% with flow rate ranging from 0.5 to 2.5 LPM.
However, the thermal efficiency enhancement, as plotted in
Figure 13b, is observed to decrease with the rise of flow rate as the rate of growth of thermal efficiency for the plain tube with increasing flow rates is higher than the rate of growth in thermal efficiency for the receiver tube fitted with stationary or rotating helical shaft. As a result, the enhancement in thermal efficiency is reduced with increasing flow rates. Moreover, the enhancement is higher when the shaft rotates at a higher rotational speed than the stationary one. Using RHS3 leads to the maximum enhancement, ranging from 14.82 to 46.47% while using SHS leads to enhancement from 5.82% up to 28.78% compared to the plain tube.
The friction factor against flow rates for all tested cases is evaluated and plotted as illustrated in
Figure 14a. As noted, the friction factor reduces as the flow rate increases, as indicated in [
52]. Moreover, it increases in the cases of SHS, RHS1, RHS2, and RHS3 compared to the plain tube. This is because the shaft causes increases in swirl flow intensity, residence time, and contact surface area for SHS. In contrast, the long time inside the receiver tube increases the contact between the HTF particles and the receiver tube wall and, as a result, increases the friction factor and pressure drop. Moreover, for the cases of RHS1, RHS2, and RHS3, increasing the rotational speed magnifies the intensity of swirl flow and turbulence. As a result, it makes the HTF move over the longer paths, increasing the friction factor compared to RSHS. Consequently, the maximum friction factor is 1.3, and it is reached at a lower flow rate of 0.5 LPM and a higher rotational speed of 21RPM (RHS3), while the lower friction factor is 0.156 and reached at a higher flow rate of 2.5 LPM and stationary insert (SHS). Therefore, the friction factor ratio reduces with the growth in flow rate, while for the RHS3 and SHS cases, the friction factor ranges from 4.1 to 7.7 times and 1.9 to 4.1 times, respectively, compared to the WIR case, as seen in
Figure 14b.
The pumping power increases by increasing the flow and using the helical shaft insert, as illustrated in
Figure 15a and stated in [
18]. Moreover, using a shaft insert leads to higher pumping power in the cases of SHS, RHS1, RHS2, and RHS3 compared with the WIR. Raising the flow rate from 0.5 to 2.5 LPM increases the pressure drop from 250 to 1400 Pa, 350 to 1600 Pa, 450 to 2400 Pa, and 500 to 3000 Pa in the cases of SHS, RHS1, RHS2, and RHS3, respectively, and consequently increasing pumping power. However, the increase in pumping power, as plotted in
Figure 15b, is observed to reduce with the flow rate rise as the pumping power is greater for the plain tube when increasing the flow rates compared to the rate of growth in pumping power for the receiver tube fitted with stationary or rotating helical shaft. As a result, the percentage rise in pumping power is decreased with rising flow rates. Moreover, the increase is higher when the shaft rotates at a higher rotational speed than the stationary one. Using RHS3 leads to the maximum increase, ranging from 404 to 850%, while using SHS increases 130 to 400% compared to the plain tube.
Considering the effect of power consumed in the pump and the DC motor rotating the helical shaft, the overall efficiency can be used to evaluate the system; as shown in
Figure 16a. It indicates an improvement of thermal efficiency for all cases with the flow rate increase due to the slight rise in the total power consumed compared to the higher growth in beneficial heat gain. So, the overall efficiency trend is the same for thermal, and the overall efficiencies enhancement is the same for the thermal efficiency enhancement, as shown in
Figure 16b.
Figure 17 shows the variations of
against flow rate.
for all cases is higher than unity, while the heat transfer enhancement is higher than the pressure drop rise. The maximum
is 1.24, achieved at 1 LPM and in the case of RHS3.
The exergy efficiency with various flow rates in all tested cases is shown in
Figure 18. Based on results plotted in
Figure 18, raising the flow rate from 0.5 to 2.5 LPM increases the useful heat gain and results in exergy efficiency enhancement from 11.11% to 36.35% in the plain tube case stated in [
50]. Inserting the helical shaft increases exergy efficiency from 14.16, 14.52, 15.14, and 15.23% to 37.81, 39.21, 38.98, and 40.41% for the cases of SHS, RHS1, RHS2, and RHS3, respectively, with raising the flow rate from 0.5 to 2.5 LPM. This result is attributed to the rising logarithmic mean temperature of the fluid,
. With boosting the flow rate that leads to both decreasing in the second term (
) and increasing the useful heat gain in the first term and consequently increasing the exergy efficiency. Increasing the total power consumption at the same flow rate due to rotating the helical shaft in the cases of RHS1, RHS2, and RHS3 does not prevent enhancing the exergy efficiency because the rate of increasing the useful heat gain is higher than increasing the total power consumption that leads to enhancement in exergy efficiency.
A comparison between the present work (static and rotating helical shaft) and different types of inserts in terms of thermal efficiency ratio, Nu number ratio, and friction ratio is provided in
Table 6. The highest efficiency ratio is 2.33 for wire matrix and twisted tape [
29]. On the other hand, they achieved a higher friction ratio of 36.02.
The filling porous [
57] achieved a maximum Nu number ratio of 17.24 and a maximum friction factor ratio of 412.62. According to the reviewed literature, using twisted tape and fins can lead to higher thermal enhancement with a lower impact on the friction factor. The experimental study of the static helical shaft has a higher efficiency ratio of 1.28 and a lower friction ratio of 4.10 compared with a numerical study of twisted tape of 1.07 and a higher friction factor ratio of 6.15. While using the rotating helical shaft in the current study led to a maximum efficiency ratio of 1.46 and a maximum Nu number ratio of 2.41 compared to fins and twisted tape, but as a penalty of maximum friction factor ratio of 7.79.