Next Article in Journal
Adaptive Absolute Ego-Motion Estimation Using Wearable Visual-Inertial Sensors for Indoor Positioning
Previous Article in Journal
Modeling and Closed Loop Flight Testing of a Fixed Wing Micro Air Vehicle
Previous Article in Special Issue
Design and Performance Assessment of a Solid-State Microcooler for Thermal Neuromodulation
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Editorial

Editorial for the Special Issue on Wireless Microdevices and Systems for Biomedical Applications

by
Paulo Mateus Mendes
CMEMS, University of Minho, 4800-058 Guimarães, Portugal
Micromachines 2018, 9(3), 112; https://doi.org/10.3390/mi9030112
Submission received: 27 February 2018 / Accepted: 27 February 2018 / Published: 5 March 2018
(This article belongs to the Special Issue Wireless Microdevices and Systems for Biomedical Applications)
Wireless microdevices are getting smaller and smaller, and in this special issue seven papers address a few miniaturization challenges in the biomedical field, which are common across different applications. Kargaran et al. [1] proposes a new ultra-low-voltage ultra-low-power LNA, where the reduced current consumption of only 160 μA, on a supply as low as 0.18 V, has potential to enable future RF receivers for ultra-low-power implantable devices. Lo et al. [2] presents an implantable functional electrical stimulation (IFES) for gastrointestinal (GI) tract modulation to treat GI dysmotility. They present a miniaturized wireless implant capable of modulating and recording GI motility. The integration challenge was addressed, where the implant incorporates a custom-made system-on-a-chip (SoC), and a heterogeneous system-in-a-package (SiP) to achieve device miniaturization and integration. The developed technology was used for in vivo experiments using both rodent and porcine models to validate the effectiveness of the implant. Zhang et al. [3] also addressed the integration challenge of device miniaturization, while keeping in mind that such systems need to be connected to external devices, e.g., to develop closed loop control devices. They present the design of a wireless, implantable, multi-channel, programmable stimulator with arbitrary channel combination, which is able to establish a wireless communication link between a specified Android-based graphical user interface (GUI). The experimental results demonstrated a successful independent configuration between different channels, as well as an arbitrary channel combination of the implantable device. Li et al. [4] presented a device that features both wireless power and communications using the same pair of coils. The developed device allows a transcorneal stimulation with an amplitude range of 5 μA to 320 μA, a frequency range of 10 Hz to 160 Hz, and a duty ratio range of 2.5% to 20%. After coating with biocompatible silicone, the whole implant has dimensions only of 6 mm in diameter, with a thickness of less than 1 mm. The full system functionality and electrical performance were demonstrated with measurement results. The work by Kim et al. [5] is related with the propulsion of a mm-sized robot. In their work, after design and system optimization, a 3-mm micro-robot that simultaneously generated a propulsion force and torque, while receiving electrical energy via wireless power transfer, was successfully fabricated and verified. The work by Fernandes et al. [6] is related with system integration towards a full solid-state cooler with the ability to modulate the neural activity of rodents, without the use of large and unpractical water pipes. A miniaturized solid-state device was designed, featuring the potential for wireless power and communications, where it was possible to achieve neuromodulation temperatures lower than 30°C, while the hot side was kept below 43 °C. Dinis et al. [7] presented a review of representative state-of-the-art wireless power capabilities for implantable electronic devices, ranging from inductive coupling to ultrasounds. As the standard methodologies are in the limit of the power that can be safely transmitted to an implant, a new approach, capable of multiplying the available power inside a brain phantom for the same specific absorption rate (SAR) value, was proposed and verified with both simulation and measured data.

References

  1. Kargaran, E.; Manstretta, D.; Castello, R. Design Considerations for a Sub-mW Wireless Medical Body-Area Network Receiver Front End. Micromachines 2018, 9, 31. [Google Scholar] [CrossRef]
  2. Lo, Y.-K.; Wang, P.-M.; Dubrovsky, G.; Wu, M.-D.; Chan, M.; Dunn, J.C.Y.; Liu, W. A Wireless Implant for Gastrointestinal Motility Disorders. Micromachines 2018, 9, 17. [Google Scholar] [CrossRef]
  3. Zhang, Y.; Luo, D.; Ou, T.; Yuan, Z.; Huang, H.; You, L.; Yue, Y.; Zhang, M.; Li, D.; Li, G.; Yuan, K.; Wang, Z. Design of a Compact Wireless Multi-Channel High Area-Efficient Stimulator with Arbitrary Channel Configuration. Micromachines 2018, 9, 6. [Google Scholar] [CrossRef]
  4. Li, X.; Lu, Y.; Meng, X.; Tsui, C.-Y.; Ki, W.-H. Optic Nerve Stimulation System with Adaptive Wireless Powering and Data Telemetry. Micromachines 2017, 8, 368. [Google Scholar] [CrossRef]
  5. Kim, D.; Hwang, K.; Park, J.; Park, H.H.; Ahn, S. Miniaturization of Implantable Micro-Robot Propulsion Using a Wireless Power Transfer System. Micromachines 2017, 8, 269. [Google Scholar] [CrossRef]
  6. Fernandes, J.; Vendramini, E.; Miranda, A.M.; Silva, C.; Dinis, H.; Coizet, V.; David, O.; Mendes, P.M. Design and Performance Assessment of a Solid-State Microcooler for Thermal Neuromodulation. Micromachines 2018, 9, 47. [Google Scholar] [CrossRef]
  7. Dinis, H.; Colmiais, I.; Mendes, P.M. Extending the Limits of Wireless Power Transfer to Miniaturized Implantable Electronic Devices. Micromachines 2017, 8, 359. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Mendes, P.M. Editorial for the Special Issue on Wireless Microdevices and Systems for Biomedical Applications. Micromachines 2018, 9, 112. https://doi.org/10.3390/mi9030112

AMA Style

Mendes PM. Editorial for the Special Issue on Wireless Microdevices and Systems for Biomedical Applications. Micromachines. 2018; 9(3):112. https://doi.org/10.3390/mi9030112

Chicago/Turabian Style

Mendes, Paulo Mateus. 2018. "Editorial for the Special Issue on Wireless Microdevices and Systems for Biomedical Applications" Micromachines 9, no. 3: 112. https://doi.org/10.3390/mi9030112

APA Style

Mendes, P. M. (2018). Editorial for the Special Issue on Wireless Microdevices and Systems for Biomedical Applications. Micromachines, 9(3), 112. https://doi.org/10.3390/mi9030112

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop