Experimental Study of the Effect of High Service Temperature on the Flexural Performance of Near-Surface Mounted (NSM) Carbon Fiber-Reinforced Polymer (CFRP)-Strengthened Concrete Beams
Abstract
:1. Introduction
2. Experimental Program
2.1. Experimental Test Setup
2.2. Instrumentation
2.3. Materials
3. Results and Discussion
3.1. Shrinkage Effects on Instantaneous Deflection of Concrete Beams
3.2. Load–Deflection Curves
3.3. Failure Mode
3.4. Strain Distribution along the CFRP Strip
4. Finite Element Analysis
4.1. Description of FE Model
4.2. Materials Definition
4.3. FE Results
5. Conclusions
- No considerable differences can be observed in the load–deflection curve when specimens are subjected to 40 °C (i.e., series 1). This behavior can be attributed to 40 °C being far below the Tg of the epoxy resin.
- In series 2, as a result of the increase in temperature near or beyond the Tg, the stiffness and the ultimate load of strengthened and unstrengthened specimens decreased. The interface bond capacity between epoxy and concrete could have been affected, and the efficiency of the strengthening system showed some reduction, thus making the beam to be more prone to experience end deboning failure.
- In both series of specimens, the failure mode of the control unstrengthened beams was concrete crushing after steel yielding. For the strengthened beams under 20, 40, and 60 °C, the failure mode was FRP rupture. With the increase of temperature up to 70 °C, the beam failed by end debonding. Finally, specimens under 85 °C experienced concrete crushing and, as a result, the load suddenly dropped without giving place to end debonding. This failure mode can be attributed to the reduction in mechanical properties of concrete and epoxy when submitted to higher temperature.
- No end debonding or significant reduction in ultimate load occurred for specimens being tested up to 60 °C, thus showing a good performance of the NSM strengthening system.
- The application of temperature exceeding the epoxy Tg generated a small reduction in the stiffness of the specimen and a decrease by 3.48%, 3.95%, and 10.45% in the ultimate capacity of beams CB-2-70, SB2S-2-70, and SB2S-2-85, respectively.
- The effect of temperature on the experimental bond behavior of specimen at 40 °C was studied in one of the strengthened beams (i.e., SB1S-1 specimens). With the increase in the temperature, strains (and stresses) in the CFRP strip increased.
- A systematic procedure was applied to consider the effect of shrinkage in short-term response of the specimens. It was observed that the increase in the concrete shrinkage resulted in a reduction of the elements’ stiffness and cracking load. Good agreement was observed between analytical predictions and experimental results.
- A simple but trustable FE model accounting for initial shrinkage and effects of temperature was created to be compared with experimental work. In all cases, numerical models correctly predict the experimental load–deflection responses and failure modes.
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Pellegrino, C.; Sena-Cruz, J. Design Procedures for the Use of Composites in Strengthening of Reinforced Concrete Structures: State-of-the-Art Report of the Rilem Technical Committee 234-Duc; Springer: Dordrecht, The Netherlands, 2016; p. 392. [Google Scholar] [CrossRef]
- De Lorenzis, L.; Teng, J.G. Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures. Compos. Part B 2007, 38, 119–143. [Google Scholar] [CrossRef]
- Parretti, R.; Nanni, A. Strengthening of RC members using near-surface mounted FRP composites: Design overview. Adv. Struct. Eng. 2004, 7, 469–483. [Google Scholar] [CrossRef]
- Michel, M.; Ferrier, E. Effect of curing temperature conditions on glass transition temperature values of epoxy polymer used for wet lay-up applications. Constr. Build. Mater. 2020, 231, 117206. [Google Scholar] [CrossRef]
- Silva, P.; Fernandes, P.; Sena-Cruz, J.; Xavier, J.; Castro, F.; Soares, D.; Carneiro, V. Effects of different environmental conditions on the mechanical characteristics of a structural epoxy. Compos. Part B 2016, 88, 55–63. [Google Scholar] [CrossRef] [Green Version]
- Michels, J.; Sena-Cruz, J.; Christen, R.; Czaderski, C.; Motavalli, M. Mechanical performance of cold-curing epoxy adhesives after different mixing and curing procedures. Compos. Part B 2016, 98, 434–443. [Google Scholar] [CrossRef] [Green Version]
- Firmo, J.P.; Roquette, M.G.; Correia, J.R.; Azevedo, A.S. Influence of elevated temperatures on epoxy adhesive used in CFRP strengthening systems for civil engineering applications. Int. J. Adhes. Adhes. 2019, 93, 102333. [Google Scholar] [CrossRef]
- Fib Bulletin 90. Externally Applied FRP Reinforcement for Concrete Structures; International Federation for Structural Concrete: Lausanne, Switzerland, 2019. [Google Scholar]
- Michels, J.; Widmann, R.; Czaderski, C.; Allahvirdizade, R.; Motavalli, M. Glass transition evaluation of commercially available epoxy resins used for civil engineering applications. Compos. Part B 2015, 77, 484–493. [Google Scholar] [CrossRef]
- Klamer, E.L. Influence of Temperature on Concrete Beams Strengthened in Flexure with CFRP. Ph.D. Thesis, TU Eindhoven, Eindhoven, The Netherlands, 2009. [Google Scholar]
- Ferrier, E.; Michel, L.; Jurkiewiez, B.; Hamelin, P. Creep behavior of adhesives used for external FRP strengthening of RC structures. Constr. Build. Mater. 2011, 25, 461–467. [Google Scholar] [CrossRef]
- Bisby, L.A.; Green, M.F. Resistance to freezing and thawing of fiber–reinforced polymer–concrete bond. ACI Struct. J. 2002, 99, 215–223. [Google Scholar]
- Leone, M.; Aiello, M.A.; Matthys, S. Effect of elevated service temperature on bond between FRP EBR systems and concrete. Compos. Part B 2009, 40, 85–93. [Google Scholar] [CrossRef]
- El-Hacha, R.; Rizkalla, S.H. Near-surface-mounted fiber-reinforced polymer reinforcements for flexural strengthening of concrete structures. ACI Struct. J. 2004, 101, 717–726. [Google Scholar]
- Sharaky, I.A.; Baena, M.; Barris, C.; Sallam, H.E.M.; Torres, L. Effect of axial stiffness of NSM FRP reinforcement and concrete cover confinement on flexural behaviour of strengthened RC beams: Experimental and numerical study. Eng. Struct. 2018, 173, 987–1001. [Google Scholar] [CrossRef]
- Obaidat, Y.T.; Barham, W.S.; Aljarah, A.H. New anchorage technique for NSM-CFRP flexural strengthened RC beam using steel clamped end plate. Constr. Build. Mater. 2020, 263, 20246. [Google Scholar] [CrossRef]
- Sena-Cruz, J.M.; Barros, J. Bond between near surface mounted carbon-fiber-reinforced polymer laminate strips and concrete. J. Compos. Constr. 2004, 8, 519–527. [Google Scholar] [CrossRef] [Green Version]
- Sena-Cruz, J.M.; Barros, J.A.; Coelho, M.R.; Silva, L.F. Efficiency of different techniques in flexural strengthening of RC beams under monotonic and fatigue loading. Constr. Build. Mater. 2012, 29, 175–182. [Google Scholar] [CrossRef] [Green Version]
- Dias, S.J.; Barros, J.A.; Janwaen, W. Behavior of RC beams flexurally strengthened with NSM CFRP laminates. Compos. Struct. 2018, 201, 363–376. [Google Scholar] [CrossRef]
- Barris, B.; Sala, P.; Gómez, J.; Torres, L. Flexural behaviour of FRP reinforced concrete beams strengthened with NSM CFRP strips. Compos. Struct. 2020, 112059. [Google Scholar] [CrossRef]
- Yu, B.; Kodur, V.K.R. Fire behavior of concrete T-beams strengthened with near-surface mounted FRP reinforcement. Eng. Struct. 2014, 80, 350–361. [Google Scholar] [CrossRef]
- Palmieri, A.; Matthys, S.; Taerwe, L. Fire endurance and residual strength of insulated concrete beams strengthened with near-surface mounted reinforcement. J. Compos. Constr. 2012, 17, 454–462. [Google Scholar] [CrossRef] [Green Version]
- Palmieri, A.; Matthys, S.; Taerwe, L. Strengthening with near surface mounted reinforcement: Structural and fire behavior. In Proceedings of the 3th International Congress and Exhibition Fib “Think Globally, Build Locally”, Washington, DC, USA, 29 May–2 June 2010; pp. 1–10. [Google Scholar]
- Palmieri, A.; Matthys, S.; Taerwe, L. Experimental investigation on fire endurance of insulated concrete beams strengthened with near surface mounted FRP bar reinforcement. Compos. Part B 2012, 43, 885–895. [Google Scholar] [CrossRef]
- Firmo, J.P.; Correia, J.R. Fire behaviour of thermally insulated RC beams strengthened with EBR-CFRP strips: Experimental study. Compos. Struct. 2015, 122, 144–154. [Google Scholar] [CrossRef]
- Firmo, J.P.; Correia, J.R. Fire behaviour of thermally insulated RC beams strengthened with NSM-CFRP strips: Experimental study. Compos. Part B 2015, 76, 112–121. [Google Scholar] [CrossRef]
- Carlos, T.B.; Rodrigues, J.P.C.; de Lima, R.C.; Dhima, D. Experimental analysis on flexural behaviour of RC beams strengthened with CFRP laminates and under fire conditions. Compos. Struct. 2018, 189, 516–528. [Google Scholar] [CrossRef]
- Jadooe, A.; Al-Mahaidi, R.; Abdouka, K. Experimental and numerical study of strengthening of heat-damaged RC beams using NSM CFRP strips. Constr. Build. Mater. 2017, 154, 899–913. [Google Scholar] [CrossRef]
- Haddad, R.H.; Almomani, O.A. Recovering flexural performance of thermally damaged concrete beams using NSM CFRP strips. Constr. Build. Mater. 2017, 154, 632–643. [Google Scholar] [CrossRef]
- Burke, P.J.; Luke, A.B.; Mark, F.G. Effects of elevated temperature on near surface mounted and externally bonded FRP strengthening systems for concrete. Cem. Concr. Compos. 2013, 35, 190–199. [Google Scholar] [CrossRef]
- Firmo, J.P.; Correia, J.R.; Bisby, L.A. Fire behaviour of FRP-strengthened reinforced concrete structural elements: A state-of-the-art review. Compos. Part B 2015, 80, 198–216. [Google Scholar] [CrossRef]
- Klamer, E.L.; Dick, A.H.; Michael, C.J.H. The influence of temperature on RC beams strengthened with externally bonded CFRP reinforcement. Heron 2008, 53, 157–185. [Google Scholar]
- Krzywoń, R. Behavior of EBR FRP strengthened beams exposed to elevated temperature. Procedia. Eng. 2017, 193, 297–304. [Google Scholar] [CrossRef]
- Silva, P.M.; Escusa, G.G.; Sena-Cruz, J.M.; Azenha, M. Experimental investigation of RC slabs strengthened with NSM CFRP system subjected to elevated temperatures up to 80 °C. In Proceedings of the 8th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering, CICE, Hong Kong, China, 14–16 December 2016. [Google Scholar]
- Ferrier, E.; Rabinovitch, O.; Michel, L. Mechanical behavior of concrete–resin/adhesive–FRP structural assemblies under low and high temperatures. Constr. Build. Mater. 2016, 127, 1017–1028. [Google Scholar] [CrossRef]
- Abed, F.; Oucif, C.; Awera, Y.; Mhanna, H.H.; Alkhraisha, H. FE modeling of concrete beams and columns reinforced with FRP composites. Def. Technol. 2021, 7, 1–14. [Google Scholar] [CrossRef]
- Al-Rahmani, A.; Abed, F.H. Numerical investigation of hybrid FRP reinforced beams. In Proceedings of the 5th International Conference on Modeling, Simulation and Applied Optimization (ICMSAO), Hammamet, Tunisia, 28–30 April 2013. [Google Scholar] [CrossRef]
- Alkhraisha, H.; Mhanna, H.; Abed, F. FE Modeling of RC Beams Reinforced in Flexure with BFRP Bars Exposed to Harsh Conditions. In Sustainable Issues in Infrastructure Engineering; Springer: Cham, Switzerland, 2021; pp. 3–13. [Google Scholar] [CrossRef]
- Abed, F.H.; Al-Rahmani, A.; Al-Rahmani, A.H. Finite element simulations of the shear capacity of GFRP-reinforced concrete short beams. In Proceedings of the 5th International Conference on Modeling, Simulation and Applied Optimization (ICMSAO), Hammamet, Tunisia, 28–30 April 2013. [Google Scholar] [CrossRef]
- Abed, F.; El Refai, A.; Abdalla, S. Experimental and finite element investigation of the shear performance of BFRP-RC short beams. Structures 2019, 20, 689–701. [Google Scholar] [CrossRef]
- Hawileh, R.A.; Naser, M.; Zaidan, W.; Rasheed, H.A. Modeling of insulated CFRP strengthened reinforced concrete T-beam exposed to fire. Eng. Struct. 2009, 31, 3072–3079. [Google Scholar] [CrossRef]
- Dai, J.G.; Gao, W.Y.; Teng, J.G. Finite element modeling of insulated FRP-strengthened RC beams exposed to fire. J. Compos. Construct. 2015, 19, 04014046. [Google Scholar] [CrossRef]
- Firmo, J.P.; Arruda, M.R.T.; Correia, J.R.; Rosa, I.C. Three-dimensional finite element modelling of the fire behaviour of insulated RC beams strengthened with EBR and NSM CFRP strips. Compos. Struct. 2018, 183, 124–136. [Google Scholar] [CrossRef]
- UNE-EN 12390-3. Testing Hardened Concrete—Part 3: Compressive Strength of Test Specimens; AENOR: Madrid, Spain, 2003. [Google Scholar]
- UNE-EN 12390-6. Testing Hardened Concrete—Part 6: Tensile Splitting Strength of Test Specimens; AENOR: Madrid, Spain, 2010. [Google Scholar]
- ASTM C469/C469M-14. Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio of Concrete in Compression; ASTM International: West Conshohocken, PA, USA, 2014. [Google Scholar]
- UNE-EN ISO 15630-1. Steel for the Reinforcement and Prestressing of Concrete-Test Methods—Part 1: Reinforcing Bars, Wire Rod and Wire; AENOR: Madrid, Spain, 2011. [Google Scholar]
- S&P. S&P Cfrp Laminate, Technical Datasheet; S&P: Seewen, Switzerland, 2017. [Google Scholar]
- ISO 527-5. Plastics-Determination of Tensile Properties—Part 5: Test Conditions FOR Unidirectional Fibre-Reinforced Plastic Composites; ISO: Geneva, Switzerland, 2009; Volume 1. [Google Scholar]
- S&P. S&P Resin 220 HP Epoxy Adhesive, Technical Data Sheet; S&P: Seewen, Switzerland, 2019. [Google Scholar]
- ISO 527-1. Plastics-Determination of Tensile Properties—Part 1: General Principles; ISO: Geneva, Switzerland, 2012. [Google Scholar]
- ASTM E1356-08. Standard Test Method for Assignment of the Glass Transition Temperatures by Differential Scanning Calorimetry; ASTM International: West Conshohocken, PA, USA, 2008. [Google Scholar]
- ASTM D5023-15. Standard Test Method for Plastics: Dynamic Mechanical Properties: In Flexure (Three-Point Bending); ASTM International: West Conshohocken, PA, USA, 2015. [Google Scholar]
- Comité Euro-International du Béton (CEB). CEB-FIP Model Code 1990 (MC-90); Thomas Telford: London, UK, 1993. [Google Scholar]
- Bischoff, P.H.; Darabi, M. Unified Approach for Computing Deflection of Steel and FRP Reinforced Concrete. In Andy Scanlon Symposium on Serviceability and Safety of Concrete Structures: From Research to Practice; American Concrete Institute: Michigan, MI, USA, 2012; pp. 1–20. [Google Scholar]
- Scanlon, A.; Bischoff, P.H. Shrinkage restraint and loading history effects on deflections of flexural members. ACI Struct. J. 2008, 105, 498. [Google Scholar]
- Gribniak, V.; Kaklauskas, G.; Kliukas, R.; Jakubovskis, R. Shrinkage effect on short-term deformation behavior of reinforced concrete—When it should not be neglected. Mater. Des. 2013, 5, 1060–1070. [Google Scholar] [CrossRef]
- Gribniak, V.; Torres, L.; Kaklauskas, G.; Daniunas, A.; Kacianauskas, R.; Jakubovskis; R. Prediction of concrete shrinkage occurring prior to external loading and effect on short-term constitutive modeling and design. Adv. Struct. Eng. 2013, 16, 1061–1080. [Google Scholar] [CrossRef]
- Gilbert, R.I. Time Effect in Concrete Structures; Elsevier: Amsterdam, The Netherland, 1988; p. 321. [Google Scholar]
- International Federation for Structural Concrete (fib). Fib Model Code for Concrete Structures 2010; fib, John Wiley & Sons: New York, NY, USA, 2013. [Google Scholar]
- Fernandes, P.; Sena-Cruz, J.; Xavier, J.; Silva, P.; Pereira, E.; Cruz, J. Durability of bond in NSM CFRP-concrete systems under different environmental conditions. Compos. Part B 2018, 138, 19–34. [Google Scholar] [CrossRef] [Green Version]
- Abaqus, Version 6.16; Documentation, Abaqus v6.16. Available online: http://130.149.89.49:2080/v2016/index.html (accessed on 21 August 2016).
- EN 1992-1-1. Eurocode 2. Design of Concrete Structures—Part 1-1: General Rules and Rules for Buildings; British Standard Institution: London, UK, 2004. [Google Scholar]
- Torres, L.; Lopez-Almansa, F.; Bozzo, L.M. Tension-stiffening model for cracked flexural concrete members. J. Struct. Eng. 2004, 130, 1242–1251. [Google Scholar] [CrossRef]
Experimental Campaign | Beam ID | Test Temperature (°C) | Concrete Compressive Strength (MPa) | FRP Dimension w × h (mm2) | No. of Strips | CFRP Area (mm2) |
---|---|---|---|---|---|---|
Series 1 | CB-1-R | 20 | 31.8 | - | - | - |
CB-1-40 | 40 | - | - | - | ||
SB1S-1-R | 20 | 1.4 × 10 | 1 | 14 | ||
SB1S-1-40 | 40 | 1.4 × 10 | 1 | 14 | ||
SB2S-1-R | 20 | 1.4 × 10 | 2 | 28 | ||
SB2S-1-40 | 40 | 1.4 × 10 | 2 | 28 | ||
SB3S-1-R | 20 | 1.4 × 10 | 3 | 42 | ||
SB3S-1-40 | 40 | 1.4 × 10 | 3 | 42 | ||
Series 2 | CB-2-R | 20 | 40.8 | - | - | - |
CB-2-70 | 70 | - | - | - | ||
SB2S-2-R | 20 | 1.4 × 10 | 2 | 28 | ||
SB2S-2-60 | 60 | 1.4 × 10 | 2 | 28 | ||
SB2S-2-70 | 70 | 1.4 × 10 | 2 | 28 | ||
SB2S-2-85 | 85 | 1.4 × 10 | 2 | 28 |
Methodology | DSC | DMA | ||||
---|---|---|---|---|---|---|
Tf | Tm | Te | Storage Modulus (E′) | Loss Modulus (E″) | Loss Factor (tanδ) | |
Tg (°C) | 53.9 | 55.2 | 55.9 | 56.2 | 57.7 | 65.3 |
Beam ID | Cracking Load, Pcr (kN) | Yielding Load, Py (kN) | Ultimate Load, Pu (kN) | Ultimate CFRP Strain, εu, FRP (mm/mm) | Failure Mode 1 | ||||
---|---|---|---|---|---|---|---|---|---|
Exp. | Analyt. | Exp. | Analyt. | Exp. | Analyt. | Exp. | Exp. | Analyt. | |
CB-1-R | 6.53 | 7.98 | 39.90 | 41.29 | 41.87 | 42.59 | - | CC | CC |
CB-1-40 | 5.51 | 7.48 | 39.68 | 41.07 | 43.39 | 42.23 | - | CC | CC |
SB1S-1-R | 7.11 | 7.97 | 44.90 | 44.68 | 53.44 | 54.57 | 0.0139 | FR | FR |
SB1S-1-40 | 6.07 | 7.47 | 44.69 | 44.36 | 53.63 | 54.39 | 0.0142 | FR | FR |
SB2S-1-R | 7.21 | 7.96 | 49.40 | 47.90 | 66.50 | 65.04 | 0.0132 | FR | FR |
SB2S-1-40 | 6.12 | 7.46 | 49.27 | 47.68 | 64.06 | 64.19 | 0.0134 | FR | FR |
SB3S-1-R | 7.56 | 7.95 | 56.80 | 51.29 | 77.04 | 74.74 | 0.0127 | FR | FR |
SB3S-1-40 | 6.41 | 7.45 | 55.60 | 51.03 | 76.77 | 73.39 | 0.0124 | FR | FR |
CB-2-R | 3.69 | 6.17 | 38.59 | 38.12 | 41.71 | 39.72 | - | CC | CC |
CB-2-70 | 2.12 | 4.66 | 37.76 | 37.64 | 40.26 | 39.14 | - | CC | CC |
SB2S-2-R | 4.79 | 5.67 | 48.21 | 44.51 | 63.36 | 62.27 | 0.0131 | FR | FR |
SB2S-2-60 | 2.09 | 4.45 | 47.88 | 43.99 | 63.39 | 59.35 | 0.0119 | FR | FR |
SB2S-2-70 | 1.82 | 4.15 | 46.70 | 43.80 | 60.86 | 56.21 | 0.0103 | ED | FR |
SB2S-2-85 | 1.68 | 3.69 | 46.47 | 43.70 | 56.72 | 55.24 | - 2 | CC | FR |
Beam ID | Service Load (kN) | Deflection at Service Load, ds (mm) | Diff. (%) | Yielding Load, Py (kN) | Diff. (%) | Ultimate Load, Pu (kN) | Diff. (%) | Failure Mode 1 | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Exp. | Numeric. | Exp. | Numeric. | Exp. | Numeric. | Exp. | Numeric. | |||||
CB-1-R | 20.57 | 7.04 | 5.99 | 14.91 | 39.90 | 39.15 | 1.88 | 41.87 | 41.22 | 1.55 | CC | CC |
CB-1-40 | 19.82 | 6.65 | 6.07 | 8.72 | 39.68 | 39.11 | 1.44 | 43.39 | 40.75 | 6.08 | CC | CC |
SB1S-1-R | 21.37 | 6.70 | 5.93 | 11.49 | 44.90 | 43.39 | 3.36 | 53.44 | 55.86 | 4.53 | FR | FR |
SB1S-1-40 | 20.59 | 7.01 | 5.94 | 15.26 | 44.69 | 43.18 | 3.38 | 53.63 | 53.73 | 0.19 | FR | FR |
SB2S-1-R | 22.12 | 6.10 | 5.82 | 4.59 | 49.40 | 49.99 | 1.19 | 66.50 | 68.20 | 2.56 | FR | FR |
SB2S-1-40 | 21.32 | 6.60 | 5.78 | 12.42 | 49.27 | 48.83 | 0.89 | 64.06 | 66.07 | 3.14 | FR | FR |
SB3S-1-R | 22.85 | 6.02 | 5.67 | 5.81 | 56.80 | 54.11 | 4.74 | 77.04 | 78.77 | 2.25 | FR | FR |
SB3S-1-40 | 22.01 | 5.97 | 5.51 | 7.71 | 55.60 | 53.76 | 3.31 | 76.77 | 74.38 | 3.11 | FR | FR |
CB-2-R | 26.28 | 9.98 | 9.99 | 0.10 | 38.59 | 36.95 | 4.25 | 41.71 | 40.78 | 2.23 | CC | CC |
CB-2-70 | 24.64 | 10.20 | 10.05 | 1.47 | 37.76 | 36.38 | 3.65 | 40.26 | 39.60 | 1.64 | CC | CC |
SB2S-2-R | 29.20 | 10.31 | 9.55 | 7.37 | 48.21 | 47.49 | 1.49 | 63.36 | 64.24 | 1.39 | FR | FR |
SB2S-2-60 | 27.04 | 9.94 | 9.65 | 2.92 | 47.88 | 45.71 | 4.53 | 63.39 | 58.72 | 7.37 | FR | FR |
SB2S-2-85 | 25.63 | 9.52 | 9.51 | 0.11 | 46.47 | 44.34 | 4.58 | 56.72 | 55.55 | 2.06 | CC | CC |
Mean diff. (%) | 7.15 | Mean diff. (%) | 2.98 | Mean diff. (%) | 2.93 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Jahani, Y.; Baena, M.; Gómez, J.; Barris, C.; Torres, L. Experimental Study of the Effect of High Service Temperature on the Flexural Performance of Near-Surface Mounted (NSM) Carbon Fiber-Reinforced Polymer (CFRP)-Strengthened Concrete Beams. Polymers 2021, 13, 920. https://doi.org/10.3390/polym13060920
Jahani Y, Baena M, Gómez J, Barris C, Torres L. Experimental Study of the Effect of High Service Temperature on the Flexural Performance of Near-Surface Mounted (NSM) Carbon Fiber-Reinforced Polymer (CFRP)-Strengthened Concrete Beams. Polymers. 2021; 13(6):920. https://doi.org/10.3390/polym13060920
Chicago/Turabian StyleJahani, Younes, Marta Baena, Javier Gómez, Cristina Barris, and Lluís Torres. 2021. "Experimental Study of the Effect of High Service Temperature on the Flexural Performance of Near-Surface Mounted (NSM) Carbon Fiber-Reinforced Polymer (CFRP)-Strengthened Concrete Beams" Polymers 13, no. 6: 920. https://doi.org/10.3390/polym13060920
APA StyleJahani, Y., Baena, M., Gómez, J., Barris, C., & Torres, L. (2021). Experimental Study of the Effect of High Service Temperature on the Flexural Performance of Near-Surface Mounted (NSM) Carbon Fiber-Reinforced Polymer (CFRP)-Strengthened Concrete Beams. Polymers, 13(6), 920. https://doi.org/10.3390/polym13060920