Article

Optimization of HIV Sequencing Method Using Vela Sentosa Library on Miseq Ilumina Platform

by
Nasserdine Papa Mze
*,
Cécile Fernand-Laurent
,
Solen Daugabel
,
Olfa Zanzouri
and
Stéphanie Marque Juillet
Service de Biologie, Unité de Microbiologie, Hôpital Mignot, Centre Hospitalier de Versailles, 177 rue de Versailles, 78150 Le Chesnay, France
*
Author to whom correspondence should be addressed.
Genes 2024, 15(2), 259; https://doi.org/10.3390/genes15020259
Submission received: 19 January 2024 / Revised: 14 February 2024 / Accepted: 15 February 2024 / Published: 19 February 2024
(This article belongs to the Section Technologies and Resources for Genetics)

Abstract

:
Genotypic testing is often recommended to improve the management of patients infected with human immunodeficiency virus (HIV). To help combat this major pandemic, next-generation sequencing (NGS) techniques are widely used to analyse resistance to antiretroviral drugs. In this study, we used a Vela Sentosa kit (Vela Diagnostics, Kendall, Singapore), which is usually used for the Ion Torrent personal genome machine (PGM) platform, to sequence HIV using the Illumina Miseq platform. After RNA extraction and reverse transcriptase-polymerase chain reaction (RT-PCR), minor modifications were applied to the Vela Sentosa kit to adapt it to the Illumina Miseq platform. Analysis of the results showed the same mutations present in the samples using both sequencing platforms. The total number of reads varied from 185,069 to 752,343 and from 642,162 to 2,074,028 in the Ion Torrent PGM platform and the Illumina Miseq platform, respectively. The average depth was 21,955 and 46,856 for Ion Torrent PGM and Illumina Miseq platforms, respectively. The cost of sequencing a run of eight samples was quite similar between the two platforms (about USD 1790 for Illumina Miseq and about USD 1833 for Ion Torrent PGM platform). We have shown for the first time that it is possible to adapt and use the Vela Sentosa kit for the Illumina Miseq platform to obtain high-quality results with a similar cost.

1. Introduction

Human immunodeficiency virus (HIV) infection remains a major public health problem. Human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS) has caused the deaths of 40.4 million people since the start of the epidemic in the 1980s [1]. According to the latest available data, in 2022, 630,000 people died of HIV/AIDS-related illnesses, and 1.3 million people contracted HIV worldwide [1]. In France, 6.5 million HIV serology tests were performed by medical diagnostic laboratories in 2022 [2]. According to the estimates made by the French Ministry of Health, between 4200 and 5700 people were tested positive for HIV in 2022. This number has remained stable for several years, regardless of the mode of contamination or place of birth of those who were diagnosed to be HIV-positive. In 2022, 28% of HIV infections were discovered at an advanced stage of infection in France, and this proportion has remained stable over the past few years. Among the patients whose HIV status was confirmed in 2022, 54% were heterosexuals, 41% were men who had sex with other men (MSM), 2% were transsexuals that contracted HIV through sexual intercourse, and 1% was intravenous drug users (IDUs). Less than 1% were children under 15 years old, a large majority of whom were infected through mother-to-child transmission. Also, in 2022, 43% of HIV infections were diagnosed for the first time at a late stage. At the regional level, the incidence of HIV infection remained markedly high in the French overseas regions, hence, the importance of maintaining a high level of screening activity in those regions [2].
Currently, 23.3 million people worldwide are on anti-HIV treatment, the efficacy of which has considerably improved over the years. Today, a person living with HIV who starts an antiretroviral (ARV) treatment would have the same life expectancy as an HIV-negative person of the same age. ARV treatment prevents HIV-related illness and disability and works best when started very early in the course of HIV infection. The World Health Organization (WHO) recommends two nucleoside reverse transcriptase inhibitors (NRTIs) plus a non-nucleoside reverse transcriptase inhibitor or an integrase inhibitor for the standard first-line ARV therapy in adults and adolescents [3]. In adults, the second-line ARV therapy consists of two NRTIs combined with a ritonavir-boosted protease inhibitor. NRTIs are molecules that are active against HIV that block the enzyme that enables the synthesis of complementary DNA (cDNA) from viral RNA, prior to its integration into the genome of the infected cell. These inhibitors compete with natural nucleosides, preventing DNA chain elongation [4,5]. Non-nucleoside reverse transcriptase inhibitors (NNRTIs) have a direct inhibitory effect on HIV-1 reverse transcriptase by forming a reversible, non-competitive bond with the enzyme. NNRTIs act as non-competitive antagonists by binding to a hydrophobic region adjacent to the catalytic site of reverse transcriptase (RT) [6,7]. Protease inhibitors are molecules that bind to the active site of HIV protease [8], resulting in the formation of immature, non-infectious viral particles. HIV integrase inhibitors are molecules active against HIV-1 and HIV-2, targeting HIV integrase, the enzyme required to integrate the HIV genome into the DNA of the host cell. The inhibition of integrase prevents the integration of HIV genome into the host cell DNA, thus blocking retrovirus formation and the spread of viral infection.
ARV treatment works best when taken as prescribed by medical practitioners. Poor compliance can lead to drug resistance, enabling HIV to multiply and the disease to progress. In addition to poor compliance, another major obstacle to a successful ARV therapy is the development and acquisition of drug resistance due to mutations in HIV strains. Genotypic tests for ARV resistance are widely used to improve the therapeutic management of patients [9,10]. They are recommended at the time of diagnosis, i.e., before the initiation of treatment, in order to search for the possible transmission of resistance, which is detected in around 10% of new infections for non-NRTIs and 3% for anti-proteases [9]. Further genotypic tests are strongly recommended in the event of ARV treatment failure. Genotypic tests analyse the sequences of genes that code for viral reverse transcriptase, protease, and integrase, in comparison with those of a wild-type HIV reference strain, to identify the mutations associated with resistance [11,12,13,14]. ARV resistance is a result of the accumulation of specific mutations in HIV genes, and the presence of these mutations significantly reduces the efficacy of ARV and prolongs the duration of ARV therapy to attain curative effects [15,16,17]. The genotypic analysis of HIV isolates can detect the presence of mutations that are associated with phenotypic or clinical resistance to different ARVs [18]. There is generally a good correlation between the number of mutations associated with resistance to different drugs and the increase in the 50% inhibitory concentration (IC50).
At the Versailles Hospital Centre in Versailles, France, personal genomic machine (PGM) Ion Torrent high-throughput sequencing technology has been used, together with a commercial kit from Vela Diagnostics, since 2021, to diagnose HIV. Compared with the older diagnostic techniques, such as the Sanger dideoxy method, next-generation sequencing (NGS) enables the simultaneous reads of millions of copies of HIV genomes per run, enabling the detection of low-frequency mutations. In addition, NGS approaches enable the detection of admixtures, which is particularly important for patient follow-up [19]. In 2019, Vela Diagnostics NGS obtained the United States Food and Drug Administration (FDA) approval for HIV genotyping and resistance testing for in vitro diagnostic purposes [20].
A recent Italian study that evaluated the Vela Diagnostics system showed better results with this NGS technology, compared to Sanger sequencing, in terms of the success rate, accuracy, repeatability, and reproducibility of results [21]. Several other studies conducted prior to this Italian study had evaluated and demonstrated the performance of the Vela Dx Sentosa next-generation sequencing system for HIV-1 cDNA genotypic resistance [22,23,24,25]. In the present study, for the first time, we used a Vela Sentosa kit to sequence HIV genomes using the Illumina Miseq platform. The aim of our study was to show that it is possible to adapt the Vela kit to Miseq and obtain better results at a lower cost than with the PGM Ion Torrent sequencer.

2. Materials and Methods

2.1. Test Validation Samples

The reference HIV samples for quality control (QC) and test validation were obtained from the French National Reference Centre for HIV (Centre National de Référence HIV; CNR) in Bichat hospital, Paris, France. These samples are produced from the supernatants of the reference HIV strains under in vitro cultivation. Each year, QC samples are distributed and tested in several laboratories in France and at the Pasteur Institute (Paris, France) to assess the quality of HIV tests being performed. In addition to the QCs, we added a positive HIV control (AcroMetrixTM Genotyping HIV RT/PR mutant control, AcroMetrix, Benicia, CA, USA) and a negative control (HIV-free PCR).

2.2. RNA Extraction

All samples were centrifuged at 17,000× g for 2 h at 4 °C. After centrifugation, 400 µL of the supernatant was used to extract the viral RNA using the EZ1 virus mini kit (Qiagen S.A.S., Courtaboeuf, France) as recommended by the manufacturer.

2.3. PCR Amplification

Reverse transcriptase-polymerase chain reaction (RT-PCR) was performed using the Sentosa® SQ HIV drug resistance mutations (DRM) library kit (Vela Diagnostics, Hamburg, Germany), according to the manufacturer’s recommendations. Four primer pools were used to amplify the protease (PR), RT, and integrase (INT) genes. RT-PCR was performed with a single thermal cycling program using 1.25 µL of RT enzyme mix, 1.25 µL of each primer pool, and 10 µL of eluted RNA. The RT program was 25 °C for 2 min and 50 °C for 15 min. The PCR amplification conditions were as follows: initial denaturation at 94 °C for 2 min, followed by 50 cycles consisting of 94 °C for 15 s, 58 °C for 15 s, 57 °C for 15 s, 56 °C for 15 s, 55 °C for 15 s, 54 °C for 15 s, 53 °C for 15 s, and 68 °C for 2 min, and followed by the final extension step at 68 °C for 1 min. Each sample was tested in quadruplicate according to the primer pool used in a single PCR program.

2.4. Library Preparation for Ion Torrent PGM Platform

The library was prepared according to the Sentosa® SQ HIV DRM (Experienced User Card V1.0) manual protocol (Vela Diagnostics, Kendall, Singapore). After amplification, the PCR products were normalized and purified using the Sentosa® SQ virus solution prep kit. For each sample, 13 µL of the purified PCR product were used for enzymatic fragmentation using the Sentosa® SQ HIV DRM library kit. The ligation step was performed using 1 µL adapter and 1 µL barcode in the Ion Xpress Barcode Adapters kit (Thermo Fisher Scientific, Paris, France). The ligation program was 20 °C for 15 min, 65 °C for 5 min, and 85 °C for 2 min. After ligation, each ligated PCR product was purified with magnetic beads and eluted with 25 µL elution buffer. For each sample, 10 µL was taken to constitute a pool of all the libraries. The pool was then diluted by 1/4 with the elution buffer, and PCR and emulsion enrichment were performed on the Ion Chef instrument prior to sequencing. The three viral genes, PR, RT, and INT, were sequenced on a Sentosa® SQ 316 chip (Ion Torrent PGM) using the dedicated Sentosa® reagent kits (Vela Diagnostics, Kendall, Singapore).

2.5. Library Preparation for Illumina Miseq Platform

After PCR, 20 µL of the purified product were used for enzymatic fragmentation using the same Sentosa® SQ HIV DRM manual protocol. Ligation was performed using 10 µL of TruSeq DNA UD Indexes v2 from the Illumina platform (Illumina Inc., San Diego, CA, USA) under the following conditions: 20 °C for 20 min, 65 °C for 5 min, and 85 °C for 2 min. After ligation, each ligated PCR product was eluted with 18 µL elution buffer. For each sample, 5 µL was taken to form a pool of all the libraries. The concentration of the pooled library was set at 20 nM, and no dilution was performed. The pool was denatured with 0.05 N NaOH and diluted with HT1 to 30 pM. This diluted pool was incubated at 96 °C for 4 min using a heat block, and 15% PhiX control was added. The library products were analysed by sequencing using the Miseq v2 reagent kit (cycle 300) (Illumina Inc.) on the Illumina Miseq platform in 2 × 151 cycles and a micro flow cell.

2.6. Sequence Data Analysis

The bioinformatic analyses were performed using the Advanced Sequencing Platform (ASP) v3.13.0 available from SmartGene (SmartGene, Lausanne, Switzerland). The SmartGene HIV-1 application is based on the proprietary IDNS (Integrated Database Network System) technology of SmartGene and is accessible via a secure web interface, which can handle base called sequencing files generated through different sequencing technologies. Related SmartGene patents are EP05700367 and EP07816282. *.bam or *.fastq files obtained through the Sentosa SQ platform (Vela) or through the MiSeq platform (Illumina) were uploaded to ASP. The application first performs the following steps in an automated manner:
(1)
The paired-end detection of read files, if uploaded in the same batch;
(2)
Technology-specific quality filtering to trim or remove low-quality reads;
(3)
The establishment of a work list of the batch.
The user then selects the analysis pipeline to be used, in this case the HIV-1 PR+RT+INT targeted workflow, and selects the appropriate cut-off for ambiguous bases (background noise filtering, here, 0.5%). The automated analysis pipeline performs the following actions:
(1)
Quality filtering: R1 and R2 files are merged for Illumina data, then a sliding window (size of 25 nt) is applied to reads, enhancing the trimming of poor-quality sections having a low Phred score (<23 for the present study) and filtering short reads as well (<20 nt in this study);
(2)
Read mapping: reads passing the quality filters are mapped against HIV-1 profiles for PR, RT, and INT, generating a frame-aware nucleic acid alignment, using a proprietary alignment method of combined global and local alignments developed by SmartGene, followed by the translation of the corrected alignments into amino acid sequences;
(3)
Mapped reads are used for the creation of a frequency matrix;
(4)
Mutations are determined and validated with respect to the reference (here, HxB2, accession no. K03455) and their frequencies are calculated.
To generate the final report, the user selects the mutation cut-off (0.5–20%) above which mutations are assessed for resistance using one of the embedded HIV resistance algorithms, as well as a minimal read depth. In the present study, the algorithm developed by the French National Agency for AIDS Research (ANRS) was used [26], with a cut-off value of 20% and a minimum depth of 200. The drug resistance profile was then characterised, and the mutation frequencies were expressed as a percentage of the total number of HIV strains analysed. The final results were summarized in a list of all mutations per sample with their respective frequencies.

2.7. Statistical Analysis

All statistical tests were carried out using Microsoft Excel version 16 (Microsoft Corp., Redmond, WA, USA). The cost per sample per run (eight samples) was calculated for the sequencing preparation workflow of Illumina Miseq and Ion Torrent PGM platforms. The prices of all kits used from PCR to sequencing were included, taking into account the total number of samples that can be processed per kit.
The average values of depths and the numbers of reads were compared using the two-tailed Student t-test. The significance level was set at p < 0.05.
Cohen’s kappa coefficient was calculated to estimate the degree of agreement between the results of Ion Torrent PGM platform and Miseq Illumina platform [27].

3. Results

A total of six QCs and the single positive control were correctly sequenced, and all mutations were found with both platforms. For the Ion Torrent PGM platform, the total number of reads ranged from 185,069 to 752,343 (Figure 1). The average depth was 21,955, with an average mutation frequency of 99.3% (Figure 2). All HIV strains showed mutations that are associated with drug resistance. CQ022022, CQ032022, CQ012023, and CQ042023 strains belonged to the genetically distinct group referred to as subtype B, while CQ022023 strain was characterized as subtype A, and CQ012022 strain had genetic features of subtype F2 (Supplementary File S1).
For the Miseq Illumina platform, the total number of reads ranged from 642,162 to 2,074,028. The average depth was 46,856, with an average frequency of 99.5%. CQ022022, CQ032022, CQ012023, and CQ042023 strains were characterized as HIV-1 subtype B, while CQ022023 strain was determined to be subtype A1, and CQ012022 strain belonged to subtype F2 (Supplementary File S2).
Concerning the number of mutations, those found in the INT gene were 100% concordant (Cohen’s kappa coefficient: 1; perfect agreement) for all samples. However, a few small, non-significant discrepancies (p > 0.05) were observed in the PR and RT genes (Table 1). These discordant nucleotides have not been reported to be associated with drug resistance.
The comparison of mean reads showed a statistically significant difference between Miseq (mean total: 577,718) and PGM (mean total: 445,178) (p = 0.0017). Although the average depth was higher with the Illumina Miseq platform than with the Ion Torrent PGM platform, the difference did not reach statistical significance (p = 0.10).
Furthermore, the total duration of the preparation run was 26 h 43 min with the PGM and 26 h 28 min with Miseq. These are times taken from real runs of the protocol. In all cases, the handling of the Illumina protocol was simpler and shorter (Figure 3).
The price of a sequencing run on the Illumina Miseq platform was EUR 1640 or about USD 1790 (exchange rate on 5 January 2024), and EUR 1685 or about USD 1833 on the Ion Torrent PGM platform (Table 2).

4. Discussion

The NGS technology has become a powerful tool in the public health context of virus surveillance. The study of HIV drug resistance by sequencing is a key step in HIV/AIDS therapeutic management and strategy. Sequencing performed in the search for mutations in RT, PR, and INT genes is indicated in several clinical situations to optimise patient management [11,12,13,14].
The most common NRTI resistance-associated mutations are M184V/I. Other common discriminating mutations include K65R, K70E/G/Q, L74V/I, Y115F, and the Q151M mutation complex. The most common NNRTI resistance-associated mutations are L100I, K101E/P, K103N/S, V106A/M, Y181C/I/V, Y188C/H/L, G190A/S/E, and M230L. Each of these is associated with an intermediate-to-high level of phenotypic resistance to nevirapine. The mutations associated with PI resistance are D30N and N88D, which are major mutations associated with resistance to nelfinavir. In addition, L10F, V11I, K20TV, L23I, K43T, F53L, Q58E, A71IL, G73STCA, T74P, N83D, and L89V are known to be common non-polymorphic accessory mutations that may occur in PI resistance [28].
In France, the prevalence of viruses carrying at least one mutation associated with ARV resistance was 9.2% in 2014 [29]. This prevalence rate of ARV-resistant viruses has remained stable over time, i.e., between 10 and 13%. In comparison, during the same period in France, the prevalence rates of viruses carrying mutations associated with resistance to NRTIs, the first-generation NNRTIs, or PIs were 4.3%, 3%, and 2.4%, respectively. The prevalence of mutant HIV strains with mutations associated with resistance to rilpivirine and/or etravirine was 6%, with the majority of mutations occurring at position 138. Resistance to at least one NNRTI was found in 8.4% of HIV isolates. Mutations associated with resistance to INT inhibitors were observed in 2.7% of cases (four clinical isolates with E157Q mutation and two isolates with R263K mutation that confer resistance to dolutegravir). Moreover, the frequency of viral resistance is similar in patients infected with non-B subtypes than in patients infected with B subtype HIV-1 [30].
Since the introduction of PGM Ion Torrent sequencing technology at the Hospital Centre in Versailles in 2021, this technique has been used to study HIV resistance in over 677 patients. Ion Torrent sequencing technology is known for its simplicity, speed, and lower cost, due to its semiconductor chips [31].
The switch to a new sequencer, i.e., the Illumina Miseq platform, at our laboratory prompted us to make adjustments and adapt the Sentosa® kit supplied by Vela to the Miseq sequencer on the Illumina platform. Vela’s Sentosa kit is usually used for the PGM; this is the first time that it has been adapted for use with the Miseq Illumina. The advantage of using the Vela kit is that a single PCR can amplify all three HIV genes of interest, namely, RT, PR, and INT [32], when compared with other techniques that require PCR amplifications of individual genes [33].
Overall, the results showed a perfect concordance (Cohen’s kappa coefficient ranged from 0.97 to 1; perfect agreement) of mutations between the two techniques, validating the Miseq sequencing technique on the Illumina platform. Indeed, the latter assay performed with minor modifications met our predefined validation criteria based on recommended methods for validating an in-house genotyping assay for HIV drug resistance monitoring (Figure 3). Consequently, the test was deemed suitable for our needs and capable of replacing the Ion Torrent PGM test in our laboratory.
Interestingly, the total number of reads for each sample and the average depth were higher with the Miseq Illumina platform than with the Ion Torrent platform. This difference can be explained by the fact that the chip in Ion Torrent platform used for sequencing generates around 5 million reads, whereas Illumina platform’s micro flow cell generates around 8 million reads. In addition, the preparation of the library was simpler and faster with Miseq Illumina platform, allowing time flexibility for laboratory technicians and the rapid delivery of results. Moreover, the price of reagents was USD 1790 with the Miseq Illumina platform and USD 1833 with the Ion Torrent PGM platform. This small difference in price is due to the necessity of using several Thermo Fisher Scientific kits for library enrichment on the Ion Chef automated system prior to PGM sequencing. This enrichment step is specific to and necessary for the Ion Torrent platform, but not for the Miseq Illumina platform.

5. Conclusions

For the first time, we have shown that it is possible to use the Vela library to sequence HIV genome on the Miseq sequencer with Illumina platform. This platform is simpler and faster and provides high-quality results similar to those of the Ion Torrent PGM platform.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/genes15020259/s1, Supplementary File S1: Reports of drug resistance results with the Ion Torrent PGM platform; Supplementary File S2: Reports of drug resistance results with the Illumina Miseq platform; Supplementary File S3: Frequency of mutations with their depths found in all samples with both platforms.

Author Contributions

Conceptualization, S.M.J. and N.P.M.; methodology, N.P.M.; validation, S.M.J.; writing—original draft preparation, N.P.M.; writing—review and editing. C.F.-L., S.D. and O.Z. carried out the RNA extractions and RT-PCR. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Hospital Centre of Versailles (grant number: O2024/04).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Acknowledgments

We thank the personnel of the laboratory of Hospital Centre of Versailles, especially Benjamin Maneglier, Franck Mausoleo, and Alexandra Leocadie for their technical assistance. A big thanks to Leonardo Basco for reading and correcting this article. We also thank the SmartGene team, especially Jean Ruelle, for sequence data analysis explanations.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

AIDS, acquired immunodeficiency syndrome; ANRS, French National Agency for AIDS Research; ARV, antiretroviral; ASP, Advanced Sequencing Platform; cDNA, complementary DNA; CNR, Centre National de Référence (French National Reference Centre for HIV); DRM, drug resistance mutations; FDA, Food and Drug Administration; HIV, human immunodeficiency virus; IC50, 50% inhibitory concentration; IDNS, Integrated Database Network System; IDU, intravenous drug users; INT, integrase; MSM, men who had sex with other men; NGS, next-generation sequencing; NRTIs, nucleoside reverse transcriptase inhibitors; NNRTI, non-nucleoside reverse transcriptase inhibitors; PGM, personal genomic machine; PR, protease; QC, quality control; RT, reverse transcriptase; RT-PCR, reverse transcriptase-polymerase chain reaction; USD, United States dollars; and WHO, World Health Organization.

References

  1. Joint United Nations Programme on HIV/AIDS (UNAIDS). The Path that Ends AIDS: UNAIDS Global AIDS Update 2023; Joint United Nations Programme on HIV/AIDS: Geneva, Switzerland, 2023; Available online: https://thepath.unaids.org/wp-content/themes/unaids2023/assets/files/2023_report.pdf (accessed on 5 January 2024).
  2. Santé Publique France. Infection par le VIH. Bulletin de Santé Publique VIH-IST. November 2023. Available online: https://www.santepubliquefrance.fr/ (accessed on 5 January 2024).
  3. UNAIDS. HIV Treatment. Geneva, Switzerland: Joint United Nations Programme on HIV/AIDS. 2024. Available online: https://www.unaids.org/en/topic/treatment (accessed on 5 January 2024).
  4. Furman, P.A.; Fyfe, J.A.; St. Clair, M.H.; Weinhold, K.; Rideout, J.L.; Freeman, G.A.; Lehrman, S.N.; Bolognesi, D.P.; Broder, S.; Mitsuya, H. Phosphorylation of 3′-azido-3′-deoxythymidine and selective interactions of the 5′-triphosphate with human immunodeficiency virus reverse transcriptase. Proc. Natl. Acad. Sci. USA 1986, 83, 8333–8337. [Google Scholar] [CrossRef] [PubMed]
  5. Hart, G.J.; Orr, D.C.; Penn, C.R.; Figueiredo, H.T.; Gray, N.M.; Boehme, R.E.; Cameron, J.M. Effects of (-)-2′-deoxy-3′-thiacytidine (3TC) 5′-triphosphate on human immunodeficiency virus reverse transcriptase and mammalian DNA polymerases α, β, and γ. Antimicrob. Agents Chemother. 1992, 36, 1688–1694. [Google Scholar] [CrossRef] [PubMed]
  6. Spence, R.A.; Kati, W.M.; Anderson, K.S.; Johnson, K.A. Mechanism of inhibition of HIV-1 reverse transcriptase by nonnucleoside inhibitors. Science 1995, 267, 988–993. [Google Scholar] [CrossRef] [PubMed]
  7. Gu, Z.; Quan, Y.; Li, Z.; Arts, E.J.; Wainberg, M.A. Effects of non-nucleoside inhibitors of human immunodeficiency virus type 1 in cell-free recombinant reverse transcriptase assays. J. Biol. Chem. 1995, 270, 31046–31051. [Google Scholar] [CrossRef]
  8. Boden, D.; Markowitz, M. Resistance to human immunodeficiency virus type 1 protease inhibitors. Antimicrob. Agents Chemother. 1998, 42, 2775–2783. [Google Scholar] [CrossRef] [PubMed]
  9. Assoumou, L.; Bocket, L.; Pallier, C.; Grude, M.; Ait-Namane, R.; Izopet, J.; Raymond, S.; Charpentier, C.; Visseaux, B.; Wirden, M.; et al. Anrs Ac- Resistance Study Group. Stable prevalence of transmitted drug resistance mutations and increased circulation of non-B subtypes in antiretroviral-naive chronically HIV-infected patients in 2015/2016 in France. J. Antimicrob. Chemother. 2019, 74, 1417–1424. [Google Scholar] [CrossRef]
  10. Aulicino, P.C.; Zapiola, I.; Kademian, S.; Valle, M.M.; Fernandez Giuliano, S.; Toro, R.; Barbas, G.; Canizal, A.M.; Mayon, P.; Golemba, M.D.; et al. Pre-treatment drug resistance and HIV-1 subtypes in infants from Argentina with and without exposure to antiretroviral drugs for prevention of mother-to-child transmission. J. Antimicrob. Chemother. 2019, 74, 722–730. [Google Scholar] [CrossRef]
  11. Hertogs, K.; de Béthune, M.P.; Miller, V.; Ivens, T.; Schel, P.; Van Cauwenberge, A.; Van Den Eynde, C.; Van Gerwen, V.; Azijn, H.; Van Houtte, M.; et al. A rapid method for simultaneous detection of phenotypic resistance to inhibitors of protease and reverse transcriptase in recombinant human immunodeficiency virus type 1 isolates from patients treated with antiretroviral drugs. Antimicrob. Agents Chemother. 1998, 42, 269–276. [Google Scholar] [CrossRef]
  12. Johnston, E.; Dupnik, K.M.; Gonzales, M.J.; Winters, M.A.; Rhee, S.Y.; Imamichi, T.; Shafer, R.W. Panel of prototypical infectious molecular HIV-1 clones containing multiple nucleoside reverse transcriptase inhibitor resistance mutations. AIDS 2005, 19, 731–733. [Google Scholar] [CrossRef]
  13. Weber, J.; Vazquez, A.C.; Winner, D.; Rose, J.D.; Wylie, D.; Rhea, A.M.; Henry, K.; Pappas, J.; Wright, A.; Mohamed, N.; et al. Novel method for simultaneous quantification of phenotypic resistance to maturation, protease, reverse transcriptase, and integrase HIV inhibitors based on 3′Gag(p2/p7/p1/p6)/PR/RT/INT-recombinant viruses: A useful tool in the multitarget era of antiretroviral therapy. Antimicrob. Agents Chemother. 2011, 55, 3729–3742. [Google Scholar] [CrossRef]
  14. Saladini, F.; Giannini, A.; Boccuto, A.; Vicenti, I.; Zazzi, M. Agreement between an in-house replication competent and a reference replication defective recombinant virus assay for measuring phenotypic resistance to HIV-1 protease, reverse transcriptase, and integrase inhibitors. J. Clin. Lab. Anal. 2018, 32, e22206. [Google Scholar] [CrossRef] [PubMed]
  15. Yeni, P.G.; Hammer, S.M.; Carpenter, C.C.; Cooper, D.A.; Fischl, M.A.; Gatell, J.M.; Gazzard, B.G.; Hirsch, M.S.; Jacobsen, D.M.; Katzenstein, D.A.; et al. Antiretroviral treatment for adult HIV infection in 2002: Updated recommendations of the International AIDS Society-USA Panel. JAMA 2002, 288, 222–235, Erratum in JAMA 2003, 11, 32. [Google Scholar] [CrossRef] [PubMed]
  16. Quiros-Roldan, E.; Signorini, S.; Castelli, F.; Torti, C.; Patroni, A.; Airoldi, M.; Carosi, G. Analysis of HIV-1 mutation patterns in patients failing antiretroviral therapy. J. Clin. Lab. Anal. 2001, 15, 43–46. [Google Scholar] [CrossRef] [PubMed]
  17. Lorenzi, P.; Opravil, M.; Hirschel, B.; Chave, J.P.; Furrer, H.J.; Sax, H.; Perneger, T.V.; Perrin, L.; Kaiser, L.; Yerly, S. Impact of drug resistance mutations on virologic response to salvage therapy. Swiss HIV Cohort Study. AIDS 1999, 13, F17–F21. [Google Scholar] [CrossRef] [PubMed]
  18. Sheldon, J.G.; Condra, J.H. Genotypic analysis methods for detection of drug resistance mutations in the HIV-1 proteinase and reverse transcriptase genes. Antiviral Ther. 1999, 4, 135–142. [Google Scholar] [CrossRef]
  19. Stella-Ascariz, N.; Arribas, J.R.; Paredes, R.; Li, J.Z. The role of HIV-1 drug-resistant minority variants in treatment failure. J. Infect. Dis. 2017, 216 (Suppl. S9), S847–S850. [Google Scholar] [CrossRef]
  20. May, S.; Adamska, E.; Tang, J. Evaluation of Vela Diagnostics HIV-1 genotyping assay on an automated next generation sequencing platform. J. Clin. Virol. 2020, 127, 104376. [Google Scholar] [CrossRef]
  21. Bonifacio, M.A.; Genchi, C.; Lagioia, A.; Talamo, V.; Volpe, A.; Mariggiò, M.A. Analytical assessment of the Vela Diagnostics NGS assay for HIV genotyping and resistance testing: The Apulian experience. Int. J. Mol. Sci. 2022, 23, 2727. [Google Scholar] [CrossRef]
  22. Weber, J.; Volkova, I.; Sahoo, M.K.; Tzou, P.L.; Shafer, R.W.; Pinsky, B.A. Prospective evaluation of the Vela Diagnostics Next-Generation Sequencing platform for HIV-1 genotypic resistance testing. J. Mol. Diagn. 2019, 21, 961–970. [Google Scholar] [CrossRef]
  23. Tzou, P.L.; Ariyaratne, P.; Varghese, V.; Lee, C.; Rakhmanaliev, E.; Villy, C.; Yee, M.; Tan, K.; Michel, G.; Pinsky, B.A.; et al. Comparison of an in vitro diagnostic Next-Generation Sequencing assay with Sanger sequencing for HIV-1 genotypic resistance testing. J. Clin. Microbiol. 2018, 56, e00105–e00118. [Google Scholar] [CrossRef]
  24. Raymond, S.; Nicot, F.; Abravanel, F.; Minier, L.; Carcenac, R.; Lefebvre, C.; Harter, A.; Martin-Blondel, G.; Delobel, P.; Izopet, J. Performance evaluation of the Vela Dx Sentosa next-generation sequencing system for HIV-1 DNA genotypic resistance. J. Clin. Virol. 2020, 122, 104229. [Google Scholar] [CrossRef]
  25. Raymond, S.; Nicot, F.; Carcenac, R.; Lefebvre, C.; Jeanne, N.; Saune, K.; Delobel, P.; Izopet, J. HIV-1 genotypic resistance testing using the Vela automated next-generation sequencing platform. J. Antimicrob. Chemother. 2018, 73, 1152–1157. [Google Scholar] [CrossRef]
  26. Descamps, D.; Calvez, V.; Chaix, M.L.; Charpentier, C.; Delaugerre, C.; Flandre, P.; Izopet, J.; Marcellin, A.G.; Morand-Joubert, L.; Peytavin, G.; et al. HIV-1 Genotypic Drug Resistance Interpretation’s Algorithms. Paris, France: HIV French Resistance and French ANRS-MIE (National Agency for AIDS Research—Emergent Infectious Diseases) AC43 Resistance Group. 2023. Available online: https://pnmvh.org/outil-clinique/hiv-french-resistance/ (accessed on 17 January 2024).
  27. Landis, J.R.; Koch, G.G. The measurement of observer agreement for categorical data. Biometrics 1977, 33, 159–174. [Google Scholar] [CrossRef]
  28. Clutter, D.S.; Jordan, M.R.; Bertagnolio, S.; Shafer, R.W. HIV-1 drug resistance and resistance testing. Infect. Genet. Evol. 2016, 46, 292–307. [Google Scholar] [CrossRef] [PubMed]
  29. Rapport d’expert VIH, 2016. Résistance du VIH-1 aux Antéroviraux. Available online: https://cns.sante.fr›experts-vih_resistance (accessed on 13 January 2024).
  30. Chaix, M.L.; Seng, R.; Frange, P.; Tran, L.; Avettand-Fenoël, V.; Ghosn, J.; Reynes, J.; Yazdanpanah, Y.; Raffi, F.; Goujard, C.; et al. Increasing HIV-1 non-B subtype primary infections in patients in France and effect of HIV subtypes on virological and immunological responses to combined antiretroviral therapy. Clin. Infect. Dis. 2013, 56, 880–887. [Google Scholar] [CrossRef] [PubMed]
  31. Thermo Fisher Scientific. Ion Torrent. Available online: https://www.thermofisher.com/fr/fr/home/brands/ion-torrent.html (accessed on 5 January 2024).
  32. Dessilly, G.; Goeminne, L.; Vandenbroucke, A.T.; Dufrasne, F.E.; Martin, A.; Kabamba-Mukadi, B. First evaluation of the Next-Generation Sequencing platform for the detection of HIV-1 drug resistance mutations in Belgium. PLoS ONE 2018, 13, e0209561, Erratum in PLoS ONE 2019, 14, e0211587. [Google Scholar] [CrossRef] [PubMed]
  33. Pyne, M.T.; Simmon, K.E.; Mallory, M.A.; Hymas, W.C.; Stevenson, J.; Barker, A.P.; Hillyard, D.R. HIV-1 drug resistance assay using Ion Torrent Next Generation Sequencing and on-instrument end-to-end analysis software. J. Clin. Microbiol. 2022, 60, e0025322. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Comparison of the total number of reads with Ion Torrent PGM (blue bars) and Illumina Miseq (orange bars) platforms.
Figure 1. Comparison of the total number of reads with Ion Torrent PGM (blue bars) and Illumina Miseq (orange bars) platforms.
Genes 15 00259 g001
Figure 2. Comparison of depth between Ion Torrent PGM and Illumina Miseq platforms. The figure presents the average coverage for each HIV gene with PGM Ion Torrent (blue squares) and Miseq Illumina (orange squares). PR, protease gene; RT, reverse transcriptase gene; and INT, integrase gene. “CQ” followed by a number refers to different HIV strains.
Figure 2. Comparison of depth between Ion Torrent PGM and Illumina Miseq platforms. The figure presents the average coverage for each HIV gene with PGM Ion Torrent (blue squares) and Miseq Illumina (orange squares). PR, protease gene; RT, reverse transcriptase gene; and INT, integrase gene. “CQ” followed by a number refers to different HIV strains.
Genes 15 00259 g002
Figure 3. Sequencing times with Illumina Miseq and Ion Torrent PGM.
Figure 3. Sequencing times with Illumina Miseq and Ion Torrent PGM.
Genes 15 00259 g003
Table 1. Agreement and discordance in the number of mutations (>20%).
Table 1. Agreement and discordance in the number of mutations (>20%).
GeneID HIV Strain NumberMutation Number PGM > 20%Mutation Number Miseq > 20%Number of Discordance Resistance Yes or NoConcordance
(%)
ProteaseCQ01202224231no99
CQ02202218180yes100
CQ03202219201no99
CQ01202324240yes100
CQ02202311110yes100
CQ04202314140yes100
Reverse
Transcriptase
CQ01202243430yes100
CQ02202238371no99.5
CQ03202222231yes99.5
CQ01202331310yes100
CQ02202334340yes100
CQ04202326251no99.5
IntegraseCQ01202220200yes100
CQ02202210100yes100
CQ03202218180yes100
CQ01202322220yes100
CQ02202321210yes100
CQ04202315150yes100
Table 2. Price comparison between Ion Torrent PGM and Illumina Miseq platform.
Table 2. Price comparison between Ion Torrent PGM and Illumina Miseq platform.
Library ReagentManufacturerPrice (EUR)Price, 1 run (EUR)Total Price
PGM_Ion TorrentMiseq_Illumina
Sentosa SQ HIV DRM Library Kit (96 samples)Vela2644220.331685.051640.24
Sentosa SQ Virus Solution Prep Kit (96 samples)Vela974.0581.17
MiseqR Reagent kit v2 (300 cycles)Illumina12731273
IDT for Illumina—TruSeq DNA UD Indexes v2 (96 samples)Illumina788.8865.74
Ion Xpress Barcode Adapters Kit (96 samples)ThermoFisher1757.97146.49
Ion PGMTM Hi-QTM View Chef Reagent (four reactions)ThermoFisher3171.92792.98
Ion PGMTM Hi-QTM View Chef Supplies (four reactions)ThermoFisher
Ion PGMTM Hi-QTM View Chef Solutions
(four reactions)
ThermoFisher
Ion PGMTM Hi-QTM View Sequencing Supplies
(four reactions)
ThermoFisher
Ion PGM Hi-Q View Sequencing Solutions
(four reactions)
ThermoFisher
Ion PGM Hi-Q View Sequencing dNTPs
(four reactions)
ThermoFisher
Sentosa SQ 318 Chip Kit
(one reaction)
Vela3552.6444.07
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Papa Mze, N.; Fernand-Laurent, C.; Daugabel, S.; Zanzouri, O.; Marque Juillet, S. Optimization of HIV Sequencing Method Using Vela Sentosa Library on Miseq Ilumina Platform. Genes 2024, 15, 259. https://doi.org/10.3390/genes15020259

AMA Style

Papa Mze N, Fernand-Laurent C, Daugabel S, Zanzouri O, Marque Juillet S. Optimization of HIV Sequencing Method Using Vela Sentosa Library on Miseq Ilumina Platform. Genes. 2024; 15(2):259. https://doi.org/10.3390/genes15020259

Chicago/Turabian Style

Papa Mze, Nasserdine, Cécile Fernand-Laurent, Solen Daugabel, Olfa Zanzouri, and Stéphanie Marque Juillet. 2024. "Optimization of HIV Sequencing Method Using Vela Sentosa Library on Miseq Ilumina Platform" Genes 15, no. 2: 259. https://doi.org/10.3390/genes15020259

APA Style

Papa Mze, N., Fernand-Laurent, C., Daugabel, S., Zanzouri, O., & Marque Juillet, S. (2024). Optimization of HIV Sequencing Method Using Vela Sentosa Library on Miseq Ilumina Platform. Genes, 15(2), 259. https://doi.org/10.3390/genes15020259

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop