Reproducibility of the 10-nm Solid Particle Number Methodology for Light-Duty Vehicles Exhaust Measurements

by
Tero Lähde
1,
Barouch Giechaskiel
1,*,
Giorgio Martini
1,
Joseph Woodburn
2,
Piotr Bielaczyc
2,
Daniel Schreiber
3,
Mathias Huber
3,
Panayotis Dimopoulos Eggenschwiler
3,
Corrado Fittavolini
4,
Salvatore Florio
4,
Leonardo Pellegrini
4,
Norbert Schuster
5,
Ulf Kirchner
5,
Hiroyuki Yamada
6,
Jean-Claude Momique
7,
Richard Monier
7,
Yitu Lai
8,
Timo Murtonen
9,
Joonas Vanhanen
10,
Athanasios Mamakos
11,
Christos Dardiotis
11,
Yoshinori Otsuki
12 and
Jürgen Spielvogel
13
add Show full author list remove Hide full author list
1
Joint Research Centre (JRC), European Commission, 21027 Ispra, Italy
2
BOSMAL Automotive Research and Development Institute Ltd., 43300 Bielsko-Biala, Poland
3
Swiss Federal Laboratories for Materials Science and Technology (Empa), Automotive Powertrain Technologies, CH-8600 Dübendorf, Switzerland
4
Eni S.p.A., Centro Ricerche di San Donato Milanese, 20097 Milan, Italy
5
Ford Research & Advanced Engineering Europe, 52072 Aachen, Germany
6
Mechanical Engineering Division, Tokyo Denki University, Tokyo 120-8551, Japan
7
PSA (Stellantis) Research Centre Carrières sous Poissy, 78955 Carrières sous Poissy, France
8
Xiamen Environment Protection Vehicle Emission Control Technology Center (VETC), Xiamen 361023, China
9
VTT Technical Research Centre of Finland Ltd., 02150 Espoo, Finland
10
Airmodus Ltd., 00560 Helsinki, Finland
11
AVL List GmbH, 8020 Graz, Austria
12
HORIBA Europe GmbH, 61440 Oberursel, Germany
13
TSI GmbH, 52068 Aachen, Germany
*
Author to whom correspondence should be addressed.
Atmosphere 2022, 13(6), 872; https://doi.org/10.3390/atmos13060872
Submission received: 29 April 2022 / Revised: 24 May 2022 / Accepted: 24 May 2022 / Published: 26 May 2022
(This article belongs to the Special Issue Traffic Related Emission)

Abstract

:
Many countries worldwide have introduced a limit for solid particles larger than 23 nm for the type approval of vehicles before their circulation in the market. However, for some vehicles, in particular for port fuel injection engines (gasoline and gas engines) a high fraction of particles resides below 23 nm. For this reason, a methodology for counting solid particles larger than 10 nm was developed in the Particle Measurement Programme (PMP) group of the United Nations Economic Commission for Europe (UNECE). There are no studies assessing the reproducibility of the new methodology across different laboratories. In this study we compared the reproducibility of the new 10 nm methodology to the current 23 nm methodology. A light-duty gasoline direct injection vehicle and two reference solid particle number measurement systems were circulated in seven European and two Asian laboratories which were also measuring with their own systems fulfilling the current 23 nm methodology. The hot and cold start emission of the vehicle covered a range of 1 to 15 × 1012 #/km with the ratio of sub-23 nm particles to the >23 nm emissions being 10–50%. In most cases the differences between the three measurement systems were ±10%. In general, the reproducibility of the new methodology was at the same levels (around 14%) as with the current methodology (on average 17%).

1. Introduction

In the European Union (EU), solid particle number (SPN) emissions are regulated since 2011 for light-duty vehicles (passenger cars and light commercial vehicles), when the Euro 5b emission standard came into force [1,2]. At first, the SPN limit was applicable only to vehicles applying compression ignition engines, but in 2014 (with Euro 6) it was extended to all light duty vehicles applying a direct into the cylinder fuel injection [3], thus covering also positive ignition gasoline direct injection (GDI) vehicles. Since then, many countries in Asia have also introduced the SPN limit to all vehicles or vehicles with direct injection engines only [4]. Currently the SPN limit is 6 × 1011 #/km.
The SPN measurement methodology was developed by the United Nations Economic Commission for Europe (UNECE) coordinated Particle Measurement Programme (PMP) informal working group. The original aim was to have a good repeatability and reproducibility at low emission levels typically seen downstream of diesel particulate filters (DPFs) [5]. The so called “PMP measurement system”, which is prescribed in the regulations, comprises a volatile particle remover (VPR) and a particle number counter (PNC). In the VPR, there is a hot particle number diluter (temperature 150 to 400 °C), a non-catalyzed evaporation tube (temperature 350 °C) and another cold diluter. The PNC has around 50% counting efficiency at 23 nm in order to include the primary soot particles (with particle sizes around 20 nm) as well as to avoid counting of volatile particles (volatile artefacts) formed between the VPR and PNC often detected in the sub-23 nm range [6,7,8,9].
Nevertheless, there has lately been an increasing interest in the SPN emissions in the particle size range below 23 nm. Notable levels of <23 nm diameter solid particles were reported for various vehicle/engine applications with various measurement methods [9,10,11,12,13]. The excess of SPN emissions measured in the 10–23 nm range compared to the >23 nm emissions, can reach levels of over 500% for certain engine and vehicle applications [14,15]. Usually, the excess sub-23 nm particles for GDI and DPF equipped Diesel vehicles varies between 0% and 50%, and for port fuel injection (PFI) vehicles up to 140% [9,13,16,17]. In light of these findings, the decrease of the lower diameter of 23 nm of the current regulations to 10 nm for future regulations is of interest [4]. The new methodology needs to be economical and, additionally, reproducible for <23 nm measurements [18].
The discussion for the new methodology started in 2013 at the 28th PMP group [19]. The discussion focused on keeping the link to the SPN23 methodology, keeping existing systems as similar as possible, having low particle losses at the sub-23 nm range but at the same time avoiding volatile artifacts [17]. The main differences to the current SPN23 methodology, which was briefly described above, are the requirement of a catalyzed evaporation tube in the VPR and a 65% counting efficiency at 10 nm for the PNC [20]. The catalyzed evaporation tube is required in the system to avoid volatile artefacts [21,22,23]. The new methodology which counts solid particles from approximately 10 nm, hereafter referred to as SPN10 methodology, was approved during the 81st session of the UNECE Working Party on Pollution and Energy (GRPE), in June 2020, as an amendment to the global technical regulation (GTR 15) [24]. Details can be found in “2. Materials and Methods” section or in the literature [4].
The repeatability and reproducibility of a method is important when results from different laboratories are compared and when emission limits are set [5,25]. Since the first comparison exercise in 2007 [5], the current SPN23 methodology has been extensively evaluated [26,27]. A few studies have applied the new methodology and others have compared instruments complying with the new methodology [28,29]. However, there are no inter-laboratory correlation studies about assessing the reproducibility of the recently introduced methodology. In order to assess the reproducibility of the new SPN10 methodology and compare it with the current SPN23, an inter-laboratory comparison exercise in nine different emission laboratories was conducted. One vehicle with reference equipment measuring from 23 nm and 10 nm was circulated in 7 European and 2 Asian laboratories. Cold and hot start type approval cycles were run at each laboratory. This paper presents the basic findings.

2. Materials and Methods

2.1. Overview

Laboratories in Europe and Asia measured the emissions of the same “reference” vehicle, using their own systems complying with the current 23 nm regulation and also using the same “reference” systems that were sent to them (including both 23 and 10 nm counters).
The inter-laboratory comparison exercise (ILCE) was done in two parts: the first part (Part I) included seven European emission laboratories (Lab 1 to Lab 7) and the second part (Part II) included one European laboratory and two Asian laboratories (Lab A to Lab C). The JRC participated in both parts conducting the measurements at the beginning and at the end of each part. The two parts are not comparable because maintenance of the car, including oil change, took place, plus different fuels were used at the two parts. Details will follow. The results are anonymized; the participants in alphabetical order were: BOSMAL (Bielsko-Biala, Poland) [30], Empa (Dübendorf, Switzerland), Eni (S. Donato M.se, Italy), Ford (Aachen, Germany), JRC (Ispra, Italy), PSA (Stellantis) (Carrières sous Poissy, France), Tokyo Denki University (Tokyo, Japan), VETC (Xiamen, China), and VTT (Espoo, Finland).
The companies that provided the instruments (systems) for the measurement setup in alphabetical order were: Airmodus Oy (Helsinki, Finland), AVL List GmbH (Graz, Austria), Horiba Europe (Oberursel, Germany), and TSI GmbH (Aachen, Germany). In addition, JRC provided the remaining necessary parts of the sampling setup (e.g., tubing, splitters, pumps).

2.2. Vehicle

The vehicle was a 2017 Opel Astra turbo with a gasoline direct injection (GDI) engine (displacement 999 cm3, rated power 77 kW). It had manual transmission, front wheel drive and a three-way catalyst as exhaust aftertreatment (no particulate filter) and it complied with the Euro 6b emission standard (i.e., fulfilled the limit of 6 × 1012 #/km). The curb weight was 1213 kg (without the driver), the maximum payload was 637 kg, and the test mass was set to 1451 kg.

2.3. Fuel

In the first part (Lab 1 to Lab 7), E5 market fuel from the same batch was delivered to the laboratories, while in the second part (Lab A to Lab C) each laboratory acquired their own European reference type E10 fuel, see fuel characteristics data in Table 1.

2.4. Measurement Setup

The measurement setup is given in Figure 1. All systems were sampling from the dilution tunnel with constant volume sampling (CVS). Within the grey dashed lines, in addition to the vehicle, are the instruments that were shipped to the laboratories.
Each laboratory used their own 23 nm system, compliant with the current regulation [24]. Their VPR included a non-catalyzed evaporation tube (ET) and a PNC with a counting efficiency of 50% (±12%) at 23 nm and over 90% at 41 nm (PNC23). Externally, a PNC having 65% (±15%) counting efficiency at 10 nm and >90% at 15 nm (PNC10) was connected. This PNC10 was the model A20 from Airmodus Oy (Helsinki, Finland). In parallel, a 3792E from TSI GmbH (Aachen, Germany) with the same specifications was connected as a monitor/control counter. Due to some issues in one of the reference system, the second 3792E was used very often at that system. Thus, the data set recorded with 3792E in parallel with the A20 was limited, and the results are not presented. Nevertheless, when the two PNCs were measured in parallel, their differences were within 3% (±2%). The whole system is abbreviated as ET, and depending on the lower size ET23 or ET10.
Two systems measuring both 23 nm and 10 nm PNCs were provided to the laboratories and were measuring in parallel from the dilution tunnel. Their VPR had a catalyzed evaporation tube (CS). These systems are named hereafter CSA and CSB. CSA, the AVL Particle Counter (APC) model: 489, was provided by AVL (Graz, Austria) and included two PNCs from AVL, while CSB, SPCS 2300, was provided by Horiba Europe (Oberursel, Germany) with a PNC10 from TSI. PNC23, provided by TSI (model 3791), was connected to CSB. All systems were returned to the instrument manufacturers for maintenance between the two parts of the ILCE.
The setup, which is based on the light-duty vehicle emission regulations, allows a direct comparison of the instruments which were measuring simultaneously. However, comparison of the results between different laboratories is influenced by the stability of the vehicle and the particle losses (thermophoretic, agglomeration) in the tubing between the vehicle and the tunnel. This tubing is not standardized and it can be up to 6-m long heated or insulated, with different quality of the internal surfaces.

2.5. Test Cycles

The test protocol included three cold start and five hot start world harmonized light vehicles test cycles (WLTCs). The cycle consists of four phases (low, medium, high, extra high, abbreviated as WLTC 1–4 respectively). At the beginning of the cold start tests the oil temperature was within 2 °C of the ambient temperature (23 °C), while at the hot start tests the oil temperature was >80 °C.

2.6. Calculations

All data were delivered to JRC and anonymized. At a first step, the data in each laboratory were screened manually for measurement errors, such as incomplete time series or high background particle concentration levels. In Lab 2, the dilution for the external PNC10 of the ET system was determined erroneously and the reported emissions were extremely high. Lab 5 had very high background concentrations. In Lab 1, due to communication issues, the CSA,23 had often zero time-series in the reported concentrations. These results were excluded from the further analysis as they were clear errors, which would have been detected and excluded in normal emission measurements.
In CSB, an internal filter was plugged gradually during the measurement campaign and the results with and without plugged filter deviated as much as 20%, as it was determined by the instrument manufacturer during the intermediate validation of the system. The plugging happened twice. In Lab 3, a leak was detected in the CSB internal PNC10 and it was replaced with another PNC10 (TSI 3792E, the monitor PNC at the ET system), which was within 5% of the PNC10 connected to the laboratories won systems. These problems were considered as part of the experimental uncertainties and the results were included in the final analysis. This means that the results of CSB will give the high range of expected reproducibility, as they include a 20% internal variability, plus a 5% variability of the two PNC10 that were used.
In the second step, a statistical analysis of outliers was conducted to further screen the data validity. Cochran and Grubbs tests were applied to test the emission results of all the systems for variance and average outliers, respectively [31]. Although, CSB,23 cold start WLTCs from Lab 7 were determined to be an outlier in the Cochran test, the results were kept because they were considered to represent a possible variability, as CSB was sent to Lab 7 directly after maintenance.
The particle number emissions for a system (ET, CSA, CSB) for a specific lower size (23 nm, 10 nm), SPNsize, (#/km), were calculated with the following equation:
SPNsize = PCRF × PNCsize VCVS/D
where VCVS (m3) is the total volume of the dilution tunnel and D (km) the cycle distance. PCRF (-) is the average particle number concentration reduction factor at 30 nm, 50 nm, and 100 nm for the specific system. PNCsize (#/m3) is the particle number counter concentration in a specific system with a lower size of 23 nm or 10 nm. Both PNCsize and VCVS were normalized (corrected) to the same temperature and pressure conditions.
The excess sub-23 nm (%) particles for each system was calculated as:
sub-23 nm = SPN10/SPN23 − 1
The reproducibility coefficient of variance was calculated following ISO 5725-2 (1994). Details can be found elsewhere [31]. The JRC was measured at the beginning and end of each part (four measurement campaigns). The data were treated similarly to the other laboratories and only one measurement campaign was included in the data-analysis for each ILCE part (the end measurements of each part).
To assess the stability of the vehicle emissions, the results of JRC were plotted in chronological order, but normalized to (i.e., referred to) the first tests of the first ILCE part. To assess the comparability of the systems, their differences from their mean were calculated at each laboratory. Finally, to assess the inter-laboratories variability (or between laboratories variability) the differences of each system from the mean of all laboratories were calculated.

3. Results

3.1. Vehicle Stability

The vehicle emission stability was monitored by measuring the SPN emissions at the JRC at two different vehicle emission laboratories (VELA 2 at the start and end of the first part of ILCE, VELA 1 at the start and end of second part). As it was mentioned in 2. Materials and Methods, maintenance, including oil change, was conducted after the European part, and different fuel was used between the two parts (E5 part I, E10 part II). Thus, the emissions of the two campaigns are not comparable. Nevertheless, the emissions of each system and size are normalized to the beginning of the ILCE (Part I: Start) in Figure 2.
There is a decreasing trend in the SPN with a difference reaching 10–30% between start and end of ILCE. In the European part, the start and end measurements had a difference of <10%, suggesting relatively stable vehicle functioning over the European ILCE part. In the Asian part (Part II), the start emissions were quite similar with the end of the European part (differences < 10%). However, at the end another 5–15% decrease was noted. The lower percentages are based on the CSA system that was the same system during the whole ILCE. The higher percentages with the ET system are probably due to the additional uncertainty of the different facilities (and systems) that were used between the two parts of the ILCE. Concluding, based on CSA, the differences between start of Part I and end of Part II were 10–20%, while the differences of the averages of each part were 6–10%.

3.2. WLTC Absolute Emissions

Figure 3 plots the results for each laboratory and system for the cold start WLTCs. The error bars show the intra-laboratory standard deviation (repeatability) for each system. The cold start WLTC emission levels, based on the reference ET23 systems, ranged from 3.3 × 1012 to 5.6 × 1012 #/km at the European part (Part I) and 2.5 × 1012 to 2.8 × 1012 #/km at the Asian part (Part II). The ET10 results were 3.8–5.6 × 1012 #/km at Part I and 2.6–3.2 × 1012 #/km at Part II. The hot start WLTC emissions were approximately half of the cold start emissions.
The repeatability of the measurements, shown as error bars, was on average 5% for the 23 nm measurements with all three systems (reaching 11% at Lab 3), and 4% for the 10 nm measurements (reaching 8% at Lab 7).
Appendix A gives the normalized differences for each measurement system from the mean at all laboratories, as an indication of the inter-laboratories variability with each system (or between-laboratories variability). They were within ±30%. Practically this means that the reproducibility (combination of repeatability and inter-laboratories variability) is determined by the inter-laboratories variability.

3.3. Sub-23 nm Particles

Figure 4 shows the excess of sub-23 nm particles determined by all systems for the cold start WLTCs.
The excess of sub-23 nm particles with the ET systems were in general lower (8 to 19% percentage points) than those determined with the reference systems CSA and CSB. One reason is the non-optimized sampling position of the PNC10 that could have resulted in high sub-23 nm particle losses. PNC10 was connected externally to the ET systems, a position that in some cases included valves, flowmeter, and long tubing. Another reason could be calibration uncertainties of the PNC23 counters, or even underestimation of the PNC10. Finally, the ET systems had evaporation tube instead of catalytic stripper (as the reference systems). It is possible that downstream of the evaporation tube some material condensed on the particles resulting in higher mean sizes and, consequently, lower sub-23 nm ratio.
What is of particular interest here is the variability of the sub-23 nm values between laboratories. Based on the CSA system, in the first part of the ILCE, the excess of sub-23 nm particles varied from 13% to 23% for the cold start WLTC (Figure 4a), and 32% to 46% for the hot start WLTC (Figure 4b). In the second part of the ILCE, the excess of sub-23 nm particles varied from 27% to 32% for the cold start WLTC (Figure 4a), and 40% to 56% for the hot start WLTC (Figure 4b). The average sub-23 nm value was higher for the second part of the ILCE than for the first part for all systems. Based on CSA, the fraction was 10% points higher in the second part. This suggests that not only there was a decrease in the emission levels (discussed in Figure 3), but also in the particle size from the first to second part of the ILCE. The higher fractions at both cold and hot start tests were always from the same laboratories indicating that the facilities setup might have played a role as well (e.g., tubing length from vehicle to tailpipe, heating).
Based on the values of Figure 4, the standard deviation of sub-23 nm values of the different laboratories was around 10–20% for ETs, 4–8% for CSA, and 8–15% for CSB. When considering the problems detected with CSB and the variability between the different ET systems, the accuracy of the determination of the sub-23 nm values may be assumed from the CSA results (4% to 8%).

3.4. Comparisons of Measurement Systems

Figure 5 plots the differences of each system from the mean of the three systems for each laboratory. Each color refers to a different system. The calculations were done separately for the 23 nm systems (dark colored bars) and the 10 nm systems (light colored bars). The error bars show min-max values from the cold start and hot start WLTCs.
In general, the differences of the ET and CSA systems were comparable (i.e., within ±10% in most cases) considering the variability between laboratories (around ±30%) (see Figure A1 and Figure A2 in the Appendix A). CSB had slightly higher variability (up to ±15%) due to internal problems during the ILCE. What is important though is that the variability of the 10 nm systems is not higher than the 23 nm systems variability (compare light vs. dark colored bars).

3.5. Reproducibilities

Table 2 gives the overall results with each system and the relevant reproducibility values. The mean emissions were clearly lower in the second part of the ILCE. For example, for the cold start WLTC the average emissions were 28% to 39% lower; the exact difference depending on the system. For the hot start WLTCs the emissions were 14% to 28% lower. The differences were higher, but in line, with the stability tests conducted at JRC (see Figure 2), where a 10–30% decrease was noticed. As it was mentioned in 2. Materials and Methods, the car was maintained, and the oil was changed between the two parts. In addition, different fuel was used at the two parts.
Focusing on the details of Table 2: The reproducibility of the current methodology measuring >23 nm using evaporation tube was 19–24% in the first part, but 7–19% in the second part of the ILCE. For the 10 nm counters the values were at similar or even lower levels (17–18% and 10–11% respectively). This was expected as the 10 nm emissions were measured with the same PNC10 in each lab while the 23 nm emissions with different PNC23 in each lab. The best performing system CSA had much lower reproducibility values (11–14% at the first part and 14–25% at the second, for both 23 nm and 10 nm measurements). The second system was in general in the 15–36% range. CSB variability was affected by the internal filter problems. Although the reproducibility results of the two parts were in line, the numbers of the first part are more representative as there were more laboratories involved with more tests: 65 test (first part) vs. 23 tests (second part).

3.6. Emissions in WLTC Phases

Figure 6a plots the average SPN emissions for each phase of the cold start WLTC with each system (ET, CSA, CSB) for each part of the ILCE. Part I (European) with dark colors, Part II (Asian) with light colors. The emissions were more than two times higher in the first phase of the cycle compared to the other phases. At the hot start tests the emissions were relatively equal between the phases (no figure shown). The previously discussed (Figure 3) differences between the two parts of the ILCE can also be seen here. Here it is evident that the biggest differences happened on the first phase of the WLTC with the differences gradually decreasing. At the fourth phase of the cycle the differences between the ILCE parts were within experimental uncertainty. The error bars were higher at the cold start phase (20–30%) becoming smaller as the engine was reaching stable (hot) operating conditions (2–20%).
Figure 6b plots the excess sub-23 nm particles in the same format as Figure 6a. There is an increasing trend of the sub-23 nm percentages along the cold start WLTC phases: the sub-23 nm value is lowest in the first phase (around 5%) and increases toward the fourth phase (around 40%). The percentages were slightly higher in the second part of the ILCE compared to the first part.
These results show that the higher variability at the cold start phase comes from the different absolute levels, and not from the size of particles, which was well above the cut-off size of both systems. A small size close to the cut-off curves of the systems could result in high variability.

4. Discussion

The main objective of this study was to assess the repeatability and reproducibility of the new 10 nm methodology and compare them with the current 23 nm methodology. The selection of the vehicle for this purpose was important. As the new methodology was aiming at GDI vehicles (and in the future other spark ignition vehicles), it was necessary to select a GDI vehicle. Previous inter-laboratory studies with Diesel vehicles equipped with DPF were affected by the variability of the vehicle emissions due to the DPF fill state [5,26]. Although the gasoline particulate filters (GPFs) are not so sensitive to the fill state due to the continuous passive regeneration, the experience on the long term behavior of GPFs was limited at the time of the ILCE design. Yet, a reduction of emissions over time due to ash accumulation in the filter was reported in some studies [32], and thus, it was decided to select a GDI without GPF to avoid these issues.
The emission levels of the selected GDI vehicle (without GPF) covered a range of 1 to 15 × 1012 #/km (the lower values for hot start tests). Such emission levels were typical for Euro 6b GDI vehicles [3,33,34,35,36,37]. Lower values were measured at the second part of the ILCE after maintenance, oil change, and use of E10 instead of E5. The stability tests of JRC with the same system showed a 10–30% difference. It is possible that the lower emissions reflected the higher oxygen content of the E10 fuel at the second part. A moderate increase in fuel oxygen content in low oxygen content fuels is connected to a decrease in emissions for GDIs [38,39,40]. The lack of adequate lubricant conditioning (driving > 500 km) may also explain the decreasing trend in the second part [41]. Even though the two parts of the ILCE were treated separately the conclusions would be the same treating them all together. The only difference would be that the reproducibility values would be higher, but any relative comparisons (e.g., between systems, 23 nm vs. 10 nm) would be similar. For example, the 10 nm CSA system had means of 5.0 and 3.5 × 1011 #/km at Part I and Part II respectively for the cold WLTC, with similar reproducibility values of 14% at both parts. Combining both parts, the mean would be 4.5 × 1011 #/km with 21% reproducibility. The 23 nm CSA system had means of 4.2 and 2.7 × 1011 #/km at Part I and Part II respectively, with reproducibility values of 14% at both parts. Combining them, the mean would be 3.7 × 1011 #/km with 23% reproducibility. The 10 nm ET system reproducibility would be 27% (from 10–17%).
The sub-23 nm particles compared to the >23 nm emissions were 10–50%. The lower values were noted during cold start, which means larger particles compared to the hot engine operation. In the second ILCE part, the sub-23 nm to >23 nm ratio was higher, indicating a lower mean particle size decrease probably due to the higher fuel oxygen content. Moreover, the oil change might have affected the emission characteristics [42]. In any case the sub-23 nm values were in agreement with the literature [3,33].
In addition to the laboratories own equipment, two reference systems were also circulated. The difference of the three systems from their means were within ±10% in almost all cases. Higher differences were noticed with one system due to internal issues during the ILCE (±15%). Such differences are well within the expected differences of measurement systems. In the literature, differences of 20% have been reported for both 23 nm [2,43,44] and 10 nm systems [29,45,46].
One of the most important results of this study is the reproducibility values that were calculated for the different systems. The values were 10–25%, with the exception of the CSB system that reached 35% due to the above mentioned internal issues. The maximum reproducibility coefficient of variance in this study was at the same level or slightly lower compared to studies measuring from the CVS, which reported values of 35–45% [5,27]. In both of the cited inter-laboratory studies, the diesel particle filter condition affected the repeatability. In a recent study with a diesel vehicle emitting close to the limit, the reproducibility was 22% [25]. Another study with a gasoline vehicle reported 29% reproducibility [47]. The following factors may have affected the reproducibility [45]: at emission levels >1012 #/km, agglomeration in the line between the vehicle and the dilution tunnel can result variability of SPN10 between different laboratories [45]. Similarly, thermophoretic losses are important and can be different depending on the transfer line temperature. In the ILCE the labs applied different setups: from mixing tee within one meter from the tailpipe up to 9 m tube. Some parts of the tubes were insulated and some were heated at various temperatures (from 50 up to 170 °C). Finally, the stability of the vehicle itself plays an important role. Treating the two parts separately, it was found that the stability was around 10% in the first part and 10–15% in the second part. The vehicle variability is included in the reproducibility values.
Our results proved that the 10 nm methodology has similar or even lower reproducibility than the current 23 nm methodology. In fact, this is not surprising. The 10 nm counters are less sensitive to the surface properties and chemical composition of particles [48,49], compared to the 23 nm counters [50,51]. In addition, the catalytic strippers remove the condensing species, minimizing the impact of condensation growth on the counting efficiency of the counters [23]. Nevertheless, the concentration of particles below 23 nm was practically equal or lower than the concentration of particles above 23 nm for the GDI vehicle of our study. This indicates mean particle sizes around 20 nm or higher i.e., above the 10 nm size of the new methodology. Size distributions peaking at 10 nm might result in higher variability because the counting efficiency of the systems will be different at small sizes. For example, for size distributions with mean sizes >40 nm the differences between systems are expected to be within ±10%, but below 20 nm the differences can be >30%

5. Conclusions

Seven European and two Asian laboratories measured the solid particle number emissions of a reference gasoline direct injection (GDI) vehicle with their own equipment and two reference systems that circulated to all laboratories. All systems were equipped with both 23 nm and 10 nm counters. The laboratory systems had an evaporation tube for thermal pre-treatment while the reference systems applied catalytic strippers. The aim of the inter-laboratory exercise (ILCE) was to compare the reproducibility of the new 10 nm methodology to the current 23 nm methodology.
The European (Part I: 7 European laboratories) and Asian (Part II: 2 Asian laboratories and one European) parts of the ILCE were treated separately because maintenance (including oil change) of the vehicle took place between the two parts. Furthermore, E5 market fuel from the same batch was delivered to the European laboratories, while the Asian laboratories acquired their own reference type E10 fuel. The solid particle number (SPN) emissions were 20–35% lower at the Asian part II than at the European part I. The highest differences between the ILCE parts were detected at the first phase of the cold start cycle, while the differences at the last phase were minimum (hot engine).
In general, the intra-laboratory variability for the 23 nm SPN systems were within ±8%, while for the 10 nm systems it was within ±10%. On the other hand, the inter-laboratories reproducibility was much larger up to 25% for both 23 nm and 10 nm measurements. Thus, the 10 nm methodology uncertainty was similar with the 23 nm methodology uncertainty. More specifically, the reproducibility was 7–24% for the current 23 nm methodology with evaporation tube. The addition of a 10 nm counter in the measurement system did not increase the levels (10–18%). The first reference system, CSA, had the lowest variability with values ranging between 13–25% (23 nm) and 11–20% (10 nm). The variability of the second system, CSB, was 17–36% (23 nm) and 15–28% (10 nm) due to some technical issues during the ILCE. The higher variability of all systems were typically detected at the second (Asian) part due to the smaller number of laboratories (3 laboratories), compared to the first part (7 laboratories). Within the test cycles, the variability was highest in the first phase of the WLTC, decreasing toward the last phase of the cycle, for both cold and hot start WLTC. This trend was more distinct in the first part of the ILCE where the absolute cold start levels were higher than in the second part.
The excess of particles below 23 nm were 18% (±5%) in the European part and 30% (±3%) in the Asian part for the cold start WLTC based on the first reference system CSA. The values for the hot start WLTC were 39% (±7%) and 49% (±8%) respectively. The difference between the two parts comes from the different mean particle sizes. The differences of sub-23 nm percentages between cold and hot start cycles were due to the low sub-23 nm values (i.e., large particles) during the first phase of the cold start WLTC, compared to hot start WLTC. The laboratory systems measured lower sub-23 nm fractions compared to the reference systems due to additional losses for the 10 nm counters in some laboratory systems, calibration issues, and probably due to condensational growth of the particles between the evaporation tube and the counter.
The main message of this study is that, according to the presented data, the change of the lower detection limit of systems from 23 nm to 10 nm, does not deteriorate the reproducibility of the solid particle number measurement.

Author Contributions

Formal analysis, T.L.; writing—original draft preparation, T.L., B.G.; writing—review and editing, G.M., J.W., P.B., D.S., M.H., P.D.E., C.F., S.F., L.P., N.S., U.K., H.Y., J.-C.M., R.M., Y.L., T.M., J.V., A.M., C.D., Y.O., J.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data available upon request from the corresponding author.

Acknowledgments

The authors would like to acknowledge the laboratories staff.

Conflicts of Interest

The authors declare no conflict of interest. The opinions expressed in this manuscript are those of the authors and should in no way be considered to represent an official opinion of the European Commission and the other institutes. The mention of trade names or commercial products does not constitute endorsement or recommendation by the European Commission, the other institutes, and/or the authors.

Appendix A

The differences of each 23 nm system from the mean of all laboratories for the specific system (but separately for Part I and Part II) are given in Figure A1. This is an indication of the inter-laboratories variability (or between laboratories variability). It should be reminded that the ET23 systems were different at each laboratory, while CSA and CSB systems were the same at all laboratories. The ET23 systems were within −22% and +31%, the CSA,23 within ±18%, and the CSB,23 within ±34% at Part I, but lower at Part II: ±18% (ET23), ±13% (CSA,23), ±26% (CSB,23). The differences of the systems from their mean at the hot start WLTCs were lower for Part I, but higher for Part II reaching the Part I levels.
The differences of each 10 nm system from their mean (separately for Part I and Part II) are given in Figure A2. The ET10 system was within ±20%, the CSA,23 within ±20%, and the CSB,23 within ±32% at Part I, but lower at Part II: ±18% (ET23), ±13% (CSA,23), ±26% (CSB,23). At the hot start WLTCs, the differences were lower for Part I and higher for Part II.
Figure A1. Cold start WLTC: Difference of each 23 nm system from the average of all laboratories with the specific system. European (Part I) and Asian (Part II) parts were treated separately.
Figure A1. Cold start WLTC: Difference of each 23 nm system from the average of all laboratories with the specific system. European (Part I) and Asian (Part II) parts were treated separately.
Atmosphere 13 00872 g0a1
Figure A2. Cold start WLTC: Difference of each 10 nm system from the average of all laboratories with the specific system. European (Part I) and Asian (Part II) parts were treated separately.
Figure A2. Cold start WLTC: Difference of each 10 nm system from the average of all laboratories with the specific system. European (Part I) and Asian (Part II) parts were treated separately.
Atmosphere 13 00872 g0a2

References

  1. Giechaskiel, B.; Lähde, T.; Suarez-Bertoa, R.; Clairotte, M.; Grigoratos, T.; Zardini, A.; Perujo, A.; Martini, G. Particle Number Measurements in the European Legislation and Future JRC Activities. Combust. Engines 2018, 174, 3–16. [Google Scholar] [CrossRef]
  2. Giechaskiel, B.; Mamakos, A.; Andersson, J.; Dilara, P.; Martini, G.; Schindler, W.; Bergmann, A. Measurement of Automotive Nonvolatile Particle Number Emissions within the European Legislative Framework: A Review. Aerosol Sci. Technol. 2012, 46, 719–749. [Google Scholar] [CrossRef]
  3. Giechaskiel, B.; Joshi, A.; Ntziachristos, L.; Dilara, P. European Regulatory Framework and Particulate Matter Emissions of Gasoline Light-Duty Vehicles: A Review. Catalysts 2019, 9, 586. [Google Scholar] [CrossRef] [Green Version]
  4. Giechaskiel, B.; Melas, A.; Martini, G.; Dilara, P. Overview of Vehicle Exhaust Particle Number Regulations. Processes 2021, 9, 2216. [Google Scholar] [CrossRef]
  5. Giechaskiel, B.; Dilara, P.; Andersson, J. Particle Measurement Programme (PMP) Light-Duty Inter-Laboratory Exercise: Repeatability and Reproducibility of the Particle Number Method. Aerosol Sci. Technol. 2008, 42, 528–543. [Google Scholar] [CrossRef]
  6. Giechaskiel, B.; Drossinos, Y. Theoretical Investigation of Volatile Removal Efficiency of Particle Number Measurement Systems. SAE Int. J. Engines 2010, 3, 1140–1151. [Google Scholar] [CrossRef]
  7. Johnson, K.C.; Durbin, T.D.; Jung, H.; Chaudhary, A.; Cocker, D.R.; Herner, J.D.; Robertson, W.H.; Huai, T.; Ayala, A.; Kittelson, D. Evaluation of the European PMP Methodologies during On-Road and Chassis Dynamometer Testing for Dpf Equipped Heavy-Duty Diesel Vehicles. Aerosol Sci. Technol. 2009, 43, 962–969. [Google Scholar] [CrossRef]
  8. Zheng, Z.; Durbin, T.D.; Karavalakis, G.; Johnson, K.C.; Chaudhary, A.; Cocker, D.R.; Herner, J.D.; Robertson, W.H.; Huai, T.; Ayala, A.; et al. Nature of Sub-23-Nm Particles Downstream of the European Particle Measurement Programme (PMP)-Compliant System: A Real-Time Data Perspective. Aerosol Sci. Technol. 2012, 46, 886–896. [Google Scholar] [CrossRef]
  9. Giechaskiel, B.; Vanhanen, J.; Väkevä, M.; Martini, G. Investigation of Vehicle Exhaust Sub-23 Nm Particle Emissions. Aerosol Sci. Technol. 2017, 51, 626–641. [Google Scholar] [CrossRef] [Green Version]
  10. Alanen, J.; Saukko, E.; Lehtoranta, K.; Murtonen, T.; Timonen, H.; Hillamo, R.; Karjalainen, P.; Kuuluvainen, H.; Harra, J.; Keskinen, J.; et al. The Formation and Physical Properties of the Particle Emissions from a Natural Gas Engine. Fuel 2015, 162, 155–161. [Google Scholar] [CrossRef]
  11. Chan, T.W.; Saffaripour, M.; Liu, F.; Hendren, J.; Thomson, K.A.; Kubsh, J.; Brezny, R.; Rideout, G. Characterization of Real-Time Particle Emissions from a Gasoline Direct Injection Vehicle Equipped with a Catalyzed Gasoline Particulate Filter during Filter Regeneration. Emiss. Control Sci. Technol. 2016, 2, 75–88. [Google Scholar] [CrossRef] [Green Version]
  12. Schwanzer, P.; Rabl, H.-P.; Loders, S.; Seifert, P.; Himmelstoß, S.; Gaderer, M. Difference in the Tailpipe Particle Number by Consideration of Sub-23-Nm Particles for Different Injection Settings of a GDI Engine. Emiss. Control Sci. Technol. 2019, 5, 7–22. [Google Scholar] [CrossRef]
  13. Mamakos, A.; Martini, G.; Marotta, A.; Manfredi, U. Assessment of Different Technical Options in Reducing Particle Emissions from Gasoline Direct Injection Vehicles. J. Aerosol Sci. 2013, 63, 115–125. [Google Scholar] [CrossRef]
  14. Giechaskiel, B.; Lähde, T.; Schwelberger, M.; Kleinbach, T.; Roske, H.; Teti, E.; van den Bos, T.; Neils, P.; Delacroix, C.; Jakobsson, T.; et al. Particle Number Measurements Directly from the Tailpipe for Type Approval of Heavy-Duty Engines. Appl. Sci. 2019, 9, 4418. [Google Scholar] [CrossRef] [Green Version]
  15. Toumasatos, Z.; Kontses, A.; Doulgeris, S.; Samaras, Z.; Ntziachristos, L. Particle Emissions Measurements on CNG Vehicles Focusing on Sub-23nm. Aerosol Sci. Technol. 2021, 55, 182–193. [Google Scholar] [CrossRef]
  16. Yamada, H.; Inomata, S.; Tanimoto, H. Particle and VOC Emissions from Stoichiometric Gasoline Direct Injection Vehicles and Correlation between Particle Number and Mass Emissions. Emiss. Control Sci. Technol. 2017, 3, 135–141. [Google Scholar] [CrossRef]
  17. Giechaskiel, B.; Manfredi, U.; Martini, G. Engine Exhaust Solid Sub-23 Nm Particles: I. Literature Survey. SAE Int. J. Fuels Lubr. 2014, 7, 950–964. [Google Scholar] [CrossRef]
  18. Giechaskiel, B.; Martini, G. Engine Exhaust Solid Sub-23 Nm Particles: Ii. Feasibility Study for Particle Number Measurement Systems. SAE Int. J. Fuels Lubr. 2014, 7, 935–949. [Google Scholar] [CrossRef]
  19. Giechaskiel, B.; Martini, G. JRC Literature Survey State of Knowledge on Sub-23 Nm Particles. In Proceedings of the the PMP 28th meeting, Brussels, Belgium, 21 November 2013; Available online: https://Wiki.Unece.Org/Display/Trans/PMP+28th+session (accessed on 23 May 2022).
  20. Lahde, T.; Giechaskiel, B.; Martini, G. Development of Measurement Methodology for Sub 23 Nm Particle Number (PN) Measurements. SAE Int. J. Adv. Curr. Prac. Mobil. 2020, 3, 551–560. [Google Scholar] [CrossRef]
  21. Amanatidis, S.; Ntziachristos, L.; Giechaskiel, B.; Katsaounis, D.; Samaras, Z.; Bergmann, A. Evaluation of an Oxidation Catalyst (“Catalytic Stripper”) in Eliminating Volatile Material from Combustion Aerosol. J. Aerosol Sci. 2013, 57, 144–155. [Google Scholar] [CrossRef]
  22. Melas, A.D.; Koidi, V.; Deloglou, D.; Daskalos, E.; Zarvalis, D.; Papaioannou, E.; Konstandopoulos, A.G. Development and Evaluation of a Catalytic Stripper for the Measurement of Solid Ultrafine Particle Emissions from Internal Combustion Engines. Aerosol Sci. Technol. 2020, 54, 704–714. [Google Scholar] [CrossRef]
  23. Giechaskiel, B.; Melas, A.D.; Lähde, T.; Martini, G. Non-Volatile Particle Number Emission Measurements with Catalytic Strippers: A Review. Vehicles 2020, 2, 342–364. [Google Scholar] [CrossRef]
  24. GRPE-81-10 PMP. Revisions to ECE/TRANS/WP.29/GRPE/2020/14: Sub-23 Nm PN Measurements. In Proceedings of the GRPE 81st Session, Geneva, Switzerland, 9–11 June 2020. [Google Scholar]
  25. Giechaskiel, B.; Casadei, S.; Rossi, T.; Forloni, F.; Di Domenico, A. Measurements of the Emissions of a “Golden” Vehicle at Seven Laboratories with Portable Emission Measurement Systems (PEMS). Sustainability 2021, 13, 8762. [Google Scholar] [CrossRef]
  26. Zervas, E.; Dorlhène, P.; Forti, L.; Perrin, C.; Momique, J.C.; Monier, R.; Ing, H.; Lopez, B. Interlaboratory Test of Exhaust PM Using ELPI. Aerosol Sci. Technol. 2005, 39, 333–346. [Google Scholar] [CrossRef]
  27. Myung, C.-L.; Lee, H.; Kwon, S.; Lee, S.; Jun, J.; Lee, Y.; Woo, Y.; Lee, M.; Bae, G.-N.; Park, S. Inter-Laboratory Correlation Exercise on a Light-Duty Diesel Passenger Vehicle to Verify Nano-Particle Emission Characteristics by Korea Particle Measurement Program. J. Mech. Sci. Technol. 2009, 23, 729–738. [Google Scholar] [CrossRef]
  28. Dimopoulos Eggenschwiler, P.; Schreiber, D.; Schröter, K. Characterization of the Emission of Particles Larger than 10 Nm in the Exhaust of Modern Gasoline and CNG Light Duty Vehicles. Fuel 2021, 291, 120074. [Google Scholar] [CrossRef]
  29. Giechaskiel, B. Particle Number Emissions of a Diesel Vehicle during and between Regeneration Events. Catalysts 2020, 10, 587. [Google Scholar] [CrossRef]
  30. Bielaczyc, P.; Klimkiewicz, D.; Woodburn, J.; Szczotka, A. Exhaust Emission Testing Methods—Bosmal’s Legislative and Development Emission Testing Laboratories. Combust. Engines 2019, 178, 88–98. [Google Scholar] [CrossRef]
  31. ISO 5725-2:1994; Accuracy (Trueness and Precision) of Measurement Methods and Results—Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method. International Organization for Standardization: Geneva, Switzerland, 1994.
  32. Zhang, R.; Howard, K.; Kirkman, P.; Browne, D.; Lu, Z.; He, S.; Boger, T. A Study into the Impact of Engine Oil on Gasoline Particulate Filter Performance through a Real-World Fleet Test; SAE: Warrendale, PN, USA, 2019; no. 2019-01-0299. [Google Scholar]
  33. Lähde, T.; Giechaskiel, B.; Pavlovic, J.; Suarez-Bertoa, R.; Valverde, V.; Clairotte, M.; Martini, G. Solid Particle Number Emissions of 56 Light-Duty Euro 5 and Euro 6 Vehicles. J. Aerosol Sci. 2022, 159, 105873. [Google Scholar] [CrossRef]
  34. Valverde, V.; Mora, B.A.; Clairotte, M.; Pavlovic, J.; Suarez-Bertoa, R.; Giechaskiel, B.; Astorga-LLorens, C.; Fontaras, G. Emission Factors Derived from 13 Euro 6b Light-Duty Vehicles Based on Laboratory and on-Road Measurements. Atmosphere 2019, 10, 243. [Google Scholar] [CrossRef] [Green Version]
  35. Zhao, Y.; Li, X.; Hu, S.; Ma, C. Effects of the Particulate Matter Index and Particulate Evaluation Index of the Primary Reference Fuel on Particulate Emissions from Gasoline Direct Injection Vehicles. Atmosphere 2019, 10, 111. [Google Scholar] [CrossRef] [Green Version]
  36. Peng, W.; McCaffery, C.; Kuittinen, N.; Rönkkö, T.; Cocker, D.R.; Karavalakis, G. Secondary Organic and Inorganic Aerosol Formation from a GDI Vehicle under Different Driving Conditions. Atmosphere 2022, 13, 433. [Google Scholar] [CrossRef]
  37. Kim, K.; Chung, W.; Kim, M.; Kim, C.; Myung, C.-L.; Park, S. Inspection of PN, CO2, and Regulated Gaseous Emissions Characteristics from a GDI Vehicle under Various Real-World Vehicle Test Modes. Energies 2020, 13, 2581. [Google Scholar] [CrossRef]
  38. Raza, M.; Chen, L.; Leach, F.; Ding, S. A Review of Particulate Number (PN) Emissions from Gasoline Direct Injection (GDI) Engines and Their Control Techniques. Energies 2018, 11, 1417. [Google Scholar] [CrossRef] [Green Version]
  39. Jin, D.; Choi, K.; Myung, C.-L.; Lim, Y.; Lee, J.; Park, S. The Impact of Various Ethanol-Gasoline Blends on Particulates and Unregulated Gaseous Emissions Characteristics from a Spark Ignition Direct Injection (SIDI) Passenger Vehicle. Fuel 2017, 209, 702–712. [Google Scholar] [CrossRef]
  40. Karavalakis, G.; Short, D.; Vu, D.; Villela, M.; Asa-Awuku, A.; Durbin, T.D. Evaluating the Regulated Emissions, Air Toxics, Ultrafine Particles, and Black Carbon from SI-PFI and SI-DI Vehicles Operating on Different Ethanol and Iso-Butanol Blends. Fuel 2014, 128, 410–421. [Google Scholar] [CrossRef] [Green Version]
  41. Christianson, M.G.; Bardasz, E.; Nahumck, W. Impact of Lubricating Oil Condition on Exhaust Particulate Matter Emissions from Light Duty Vehicles. SAE Int. J. Fuels Lubr. 2010, 3, 476–488. [Google Scholar] [CrossRef]
  42. Pirjola, L.; Karjalainen, P.; Heikkilä, J.; Saari, S.; Tzamkiozis, T.; Ntziachristos, L.; Kulmala, K.; Keskinen, J.; Rönkkö, T. Effects of Fresh Lubricant Oils on Particle Emissions Emitted by a Modern Gasoline Direct Injection Passenger Car. Environ. Sci. Technol. 2015, 49, 3644–3652. [Google Scholar] [CrossRef]
  43. Bielaczyc, P.; Merkisz, J.; Pajdowski, P.; Woodburn, J. Correlation between Two Commercially Available PMP-Compliant Particle Number Counting Systems. Combust. Engines 2012, 149, 10–21. [Google Scholar] [CrossRef]
  44. Giechaskiel, B.; Woodburn, J.; Szczotka, A.; Bielaczyc, P. Particulate Matter (PM) Emissions of Euro 5 and Euro 6 Vehicles Using Systems with Evaporation Tube or Catalytic Stripper and 23 Nm or 10 Nm Counters; SAE: Warrendale, PN, USA, 2020; no. 2020-01–2203. [Google Scholar]
  45. Giechaskiel, B.; Lähde, T.; Melas, A.D.; Valverde, V.; Clairotte, M. Uncertainty of Laboratory and Portable Solid Particle Number Systems for Regulatory Measurements of Vehicle Emissions. Environ. Res. 2021, 197, 111068. [Google Scholar] [CrossRef]
  46. Giechaskiel, B.; Melas, A.; Lähde, T. Detailed Characterization of Solid and Volatile Particle Emissions of Two Euro 6 Diesel Vehicles. Appl. Sci. 2022, 12, 3321. [Google Scholar] [CrossRef]
  47. Giechaskiel, B.; Casadei, S.; Mazzini, M.; Sammarco, M.; Montabone, G.; Tonelli, R.; Deana, M.; Costi, G.; Di Tanno, F.; Prati, M.; et al. Inter-Laboratory Correlation Exercise with Portable Emissions Measurement Systems (PEMS) on Chassis Dynamometers. Appl. Sci. 2018, 8, 2275. [Google Scholar] [CrossRef] [Green Version]
  48. Terres, A.; Giechaskiel, B.; Nowak, A.; Ebert, V. Calibration Uncertainty of 23nm Engine Exhaust Condensation Particle Counters with Soot Generators: A European Automotive Laboratory Comparison. Emiss. Control Sci. Technol. 2021, 7, 124–136. [Google Scholar] [CrossRef]
  49. Wang, X.; Caldow, R.; Sem, G.J.; Hama, N.; Sakurai, H. Evaluation of a Condensation Particle Counter for Vehicle Emission Measurement: Experimental Procedure and Effects of Calibration Aerosol Material. J. Aerosol Sci. 2010, 41, 306–318. [Google Scholar] [CrossRef]
  50. Giechaskiel, B.; Wang, X.; Horn, H.-G.; Spielvogel, J.; Gerhart, C.; Southgate, J.; Jing, L.; Kasper, M.; Drossinos, Y.; Krasenbrink, A. Calibration of Condensation Particle Counters for Legislated Vehicle Number Emission Measurements. Aerosol Sci. Technol. 2009, 43, 1164–1173. [Google Scholar] [CrossRef]
  51. Kiwull, B.; Wolf, J.-C.; Niessner, R. Response Characteristics of PMP Compliant Condensation Particle Counters toward Various Calibration Aerosols. Aerosol Sci. Technol. 2015, 49, 98–108. [Google Scholar] [CrossRef]
Figure 1. Schematic setup. The dashed line indicates the equipment that was shipped to all laboratories. Parts in blue are laboratories owned equipment.
Figure 1. Schematic setup. The dashed line indicates the equipment that was shipped to all laboratories. Parts in blue are laboratories owned equipment.
Atmosphere 13 00872 g001
Figure 2. Normalized cold start WLTC emissions over the two ILCE parts for two systems. Normalization was done separately for each system and size to the beginning of the ILCE (Part I: Start). Error bars show the standard deviations within the laboratory (repeatability).
Figure 2. Normalized cold start WLTC emissions over the two ILCE parts for two systems. Normalization was done separately for each system and size to the beginning of the ILCE (Part I: Start). Error bars show the standard deviations within the laboratory (repeatability).
Atmosphere 13 00872 g002
Figure 3. Cold start WLTC emissions for all laboratories and systems. Error bars show the standard deviations within the laboratories (repeatability). Part I and II refer to the European and Asian parts of the ILCE.
Figure 3. Cold start WLTC emissions for all laboratories and systems. Error bars show the standard deviations within the laboratories (repeatability). Part I and II refer to the European and Asian parts of the ILCE.
Atmosphere 13 00872 g003
Figure 4. Excess of sub-23 nm particles for all laboratories and systems: (a) cold start WLTC; (b) hot start WLTC. Error bars show the standard deviations within laboratories (repeatability). Part I and II refer to the European and Asian parts of the ILCE.
Figure 4. Excess of sub-23 nm particles for all laboratories and systems: (a) cold start WLTC; (b) hot start WLTC. Error bars show the standard deviations within laboratories (repeatability). Part I and II refer to the European and Asian parts of the ILCE.
Atmosphere 13 00872 g004
Figure 5. Difference of each system from the mean of the three systems at each laboratory. Dark color bars are 23 nm systems, while light color bars are 10 nm systems. Error bars show min-max of cold and hot tests.
Figure 5. Difference of each system from the mean of the three systems at each laboratory. Dark color bars are 23 nm systems, while light color bars are 10 nm systems. Error bars show min-max of cold and hot tests.
Atmosphere 13 00872 g005
Figure 6. Comparisons of the systems at each ILCE part for the four phases of the cold start WLTC (WLTC 1–4): (a) average emissions; (b) excess sub-23 nm particles. Dark colors are used for the first part of the ILCE. Error bars give the repeatability of the 10 nm systems only for better clarity.
Figure 6. Comparisons of the systems at each ILCE part for the four phases of the cold start WLTC (WLTC 1–4): (a) average emissions; (b) excess sub-23 nm particles. Dark colors are used for the first part of the ILCE. Error bars give the repeatability of the 10 nm systems only for better clarity.
Atmosphere 13 00872 g006
Table 1. Fuels characteristics.
Table 1. Fuels characteristics.
ParameterUnitLab 1 to Lab 7
(Part I)
Lab A, Lab B
(Part II)
Lab C
(Part II)
T10°C52.655.652.8
T50°C98.492.090.1
T90°C159.3143.9164.8
Olefins% (vol.)798
Aromatics% (vol.)32.228.228.1
Ethanol% (vol.)4.99.59.4
Oxygen% (mass)0.93.53.5
Density (15 °C)kg/m3745.6753.2747.3
Table 2. Average emissions (×1012 #/km) with each system for the two parts of the ILCE. Percentages give the reproducibility.
Table 2. Average emissions (×1012 #/km) with each system for the two parts of the ILCE. Percentages give the reproducibility.
Part I (European)Part II (Asian)
WLTCETCSACSBETCSACSB
C (23 nm)4.3 (24%)4.2 (14%)3.9 (26%)2.6 (07%)2.7 (14%)2.7 (23%)
C (10 nm)4.8 (17%)5.0 (14%)4.7 (24%)3.0 (10%)3.5 (14%)3.4 (17%)
H (23 nm)2.0 (19%)1.8 (13%)1.7 (17%)1.4 (19%)1.4 (25%)1.5 (36%)
H (10 nm)2.5 (18%)2.5 (11%)2.3 (15%)1.8 (11%)2.1 (20%)2.0 (28%)
C = cold start WLTC; H = hot start WLTC; WLTC = worldwide harmonized light vehicles test cycle.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Lähde, T.; Giechaskiel, B.; Martini, G.; Woodburn, J.; Bielaczyc, P.; Schreiber, D.; Huber, M.; Dimopoulos Eggenschwiler, P.; Fittavolini, C.; Florio, S.; et al. Reproducibility of the 10-nm Solid Particle Number Methodology for Light-Duty Vehicles Exhaust Measurements. Atmosphere 2022, 13, 872. https://doi.org/10.3390/atmos13060872

AMA Style

Lähde T, Giechaskiel B, Martini G, Woodburn J, Bielaczyc P, Schreiber D, Huber M, Dimopoulos Eggenschwiler P, Fittavolini C, Florio S, et al. Reproducibility of the 10-nm Solid Particle Number Methodology for Light-Duty Vehicles Exhaust Measurements. Atmosphere. 2022; 13(6):872. https://doi.org/10.3390/atmos13060872

Chicago/Turabian Style

Lähde, Tero, Barouch Giechaskiel, Giorgio Martini, Joseph Woodburn, Piotr Bielaczyc, Daniel Schreiber, Mathias Huber, Panayotis Dimopoulos Eggenschwiler, Corrado Fittavolini, Salvatore Florio, and et al. 2022. "Reproducibility of the 10-nm Solid Particle Number Methodology for Light-Duty Vehicles Exhaust Measurements" Atmosphere 13, no. 6: 872. https://doi.org/10.3390/atmos13060872

APA Style

Lähde, T., Giechaskiel, B., Martini, G., Woodburn, J., Bielaczyc, P., Schreiber, D., Huber, M., Dimopoulos Eggenschwiler, P., Fittavolini, C., Florio, S., Pellegrini, L., Schuster, N., Kirchner, U., Yamada, H., Momique, J. -C., Monier, R., Lai, Y., Murtonen, T., Vanhanen, J., ... Spielvogel, J. (2022). Reproducibility of the 10-nm Solid Particle Number Methodology for Light-Duty Vehicles Exhaust Measurements. Atmosphere, 13(6), 872. https://doi.org/10.3390/atmos13060872

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop