3.1. The Effect of Calcium Polysulfide Application on the Aqueous Properties of Various Metal Aqueous Solutions
Figure 1 shows the changes of dissolved oxygen (DO) in aqueous solutions of chromium, lead, copper, zinc, nickel, and cadmium when different dosages of calcium polysulfide were added.
Figure 1a shows the change of dissolved oxygen in low-concentration (5 mg/L) samples. The dosage of calcium polysulfide is shown as the ratio of groundwater to calcium polysulfide volume (GW/CaS
x). The experiment range was the (GW/CaS
x) ratio of volume from 20,000 to 1000. The initial DO of various metal samples were about 6 mg/L. When the volume ratio of (GW/CaS
x) was about 20,000–8000, the DO of sample decreased slowly. When the ratio of the (GW/CaS
x) volume dropped to 8000–1000, the dissolved oxygen of the sample decreased rapidly. When the volume of the groundwater sample was 1000 times more than the calcium polysulfide, the dissolved oxygen of various samples could be reduced to less than 1 mg/L.
Figure 1b shows the changes of DO in samples with concentrations of 100 mg/L. The adding ratio of calcium polysulfide in high-concentration samples were in the range of 2000 and 100. In terms of the volume ratio of the groundwater to calcium polysulfide, when the adding ratio of calcium polysulfide (CaS
x/GW), it was higher than 1/600 and the DO of various samples could quickly drop below 1 mg/L. When the adding ratio (CaS
x/GW) reached 1/100, the dissolved oxygen was quite close to 0.
Figure 2 shows the changes in the oxidation–reduction potential of various metal samples when different doses of calcium polysulfide were added. The initial ORP of the sample was approximately 200–400 mV. As the dosage of calcium polysulfide increased, the ORP of various metal samples showed a gradual decline. When the calcium polysulfide dosage (volume ratio of GW to CaS
x) was at the amount of 4000, the ORP of the metal samples could show negative values. When the dosage rate of calcium polysulfide reached 1000, the ORP could reach below −300 mV. For high concentrations of 100 mg/L metal samples, when the calcium polysulfide dosage rate reached 200 (volume ratio of GW/CaS
x), the ORP was almost reduced to below −400 mV. When the adding rate reached 100 (volume ratio of GW/CaS
x), the ORP could drop to nearly −470 mV.
Figure 3 shows the changes in the pH value of various aqueous metal solutions when different dosages of calcium polysulfide were added.
Figure 3a is the pH value for 5 mg/L. The initial pH of various metal water samples were about 5–6. When the dosage of calcium polysulfide (volume ratio of GW to CaS
x) was around 20,000–8000, the pH of the chromium sample could gradually rise up to about 8.9; the pH value of the lead, nickel, zinc, and cadmium samples maintained at about 6 without a significant increase. However, the pH value of the copper sample initially decreased with the increase of the calcium polysulfide dose. When the dose was at the amount of 1/8000 (volume ratio of CaS
x/GW), the pH value was only 4.99, which was the lowest. Then, the pH value rebounded. When the application rate of calcium polysulfide was greater than 1/4000, the pH of all the metal samples gradually increased as the dosage increased.
Figure 3b shows the change of the pH values of various metal aqueous samples with a concentration of 100 mg/L. The pH of the chromium sample gradually rose with the increase of the calcium polysulfide addition rate. When the calcium polysulfide dosage ratio (volume ratio of CaS
x/GW) reached 1/600, the pH value could be nearly 11; the dosage ratio was above 1/200 and the pH value was maintained at nearly 12. When the dosage ratio of calcium polysulfide was less than 1/600 (volume ratio of CaS
x/GW), the pH of copper, zinc, and cadmium samples all appeared to decrease with the increase of the calcium polysulfide addition rate. The case of the copper sample was the most significant among these metals. When the dosage of calcium polysulfide reached 1/600, the pH value of the copper sample could drop to 3.58. When the dosage of calcium polysulfide reached 1/400 or more, the pH value rebounded and rose. Calcium polysulfide is an alkaline agent. When it was added to copper, cadmium, and zinc aqueous samples, the pH value decreased. This indicates that the reaction mechanism of calcium polysulfide to these metals was different from chromium. In reference to Reaction Formula (1) of calcium polysulfide and chromium, the reaction would consume H
+ and the pH value would increase. The reaction between calcium polysulfide and other metals was inferred as Formula (6), forming metal sulfide MS, which released H
+. Therefore, when the dosage of calcium polysulfide was low, all calcium polysulfide reacted with metal ions and released H
+, leading to a drop in the pH value. When the dosage of calcium polysulfide was greater than the dosage required for the reaction with metal ions, the remaining calcium polysulfide showed the characteristics of an alkali agent, causing the pH of the aqueous sample to rebound and rise.
The most frequently concerned issue of groundwater remediation with in situ chemical technology concerned whether the application of chemical agents will cause an unrecoverable impact on groundwater properties. Conductivity was one of the indicators that was often paid attention to among them.
Figure 4 is the variation in conductivity of various metal aqueous samples with concentrations of 5 mg/L and 100 mg/L when different doses of calcium polysulfide were added. Results showed that there were little differences in conductivity regardless of what metals they were. Only the chromium sample of high concentration had a slightly higher conductivity increase than the other metals. The conductivity of various metal samples with a concentration of 5 mg/L was about 200–250 μS/cm. When the calcium polysulfide dosage was at the amount of 1/8000 (volume ratio of CaS
x/GW), the conductivity of various metal samples were 240–270 μS/cm, while when the dose was at the amount of 1/2000, the conductivity was 335–415 μS/cm. When the dose reached 1/1000, the conductivity was 440–545 μS/cm. This still met the irrigation water conductivity standard, which was 750 μS/cm. It was an acceptable range. For various metal samples with a concentration of 100 mg/L, the initial conductivity was about 350–630 μS/cm. When the calcium polysulfide dose was at the amount of 1/600 (volume ratio of CaS
x/GW), the conductivity rose to about 550–900 μS/cm; when the dose was at the amount of 1/200, the conductivity of chromium samples was about 1650 μS/cm and the other metal samples were about 1150–1250 μS/cm; when the dose reached 1/100, the conductivity of chromium samples were at the amount of 2380 μS/cm and the other metal samples were at about 1700–1900 μS/cm. Calcium polysulfide has the characteristic of high water solubility. The conductivity of groundwater rose up to about 2000 μS/cm and it was expected that the groundwater could return to the background groundwater quality within a few months.
3.2. The Removal Efficiency of Metals Lead, Nickel, Zinc, Copper, Cadmium, and Chromium in Groundwater by Calcium Polysulfide
Figure 5 shows the removal efficiency of various metal solutions with a concentration of 5 mg/L under different dosages of calcium polysulfide. The initial concentration of lead in the aqueous sample was about 5.0 mg/L. The calcium polysulfide dosage was at the range of 1/20,000–1/8000 (volume ratio of CaS
x to GW), while the removal efficiency of lead was not significant. When the calcium polysulfide dosage was about 1/4000, the lead concentration was 3.68 mg/L and the removal rate was at about 26.5%. When the dosage of calcium polysulfide increased to 1/2000, the concentration of lead was below the detection limit (0.0005 mg/L) and it was almost completely removed. The initial concentration of nickel in the groundwater sample was at about 4.8 mg/L and when the volume ratio of the groundwater sample to calcium polysulfide was at the range of 20,000–8000, the residual nickel concentration decreased significantly with the increase of the calcium polysulfide addition rate. When the CaS
x dosage was at the amount of 1/8000 (volume ratio of CaS
x to GW), the residual concentration of nickel was 1.38 mg/L and the removal rate was at about 71.4%. In addition, when the CaS
x dosage was at the amount of 1/4000 (volume ratio of CaS
x/GW), the residual concentration of nickel was lower than the detection limit (0.0009). The removal rate reached 100%, indicating that calcium polysulfide has good removal efficiency for nickel. However, when the dose of calcium polysulfide increased again, the volume ratio of calcium polysulfide to groundwater reached 1/1000. This made the concentration of nickel rise again, reaching a concentration of 3.7 mg/L. The removal efficiency of calcium polysulfide on zinc, copper, and cadmium was similar to that of nickel. As for zinc, when the dosage of calcium polysulfide was around 1/20,000 and 1/8000 (volume ratio of CaS
x/GW), the removal efficiency of zinc increased rapidly with the increase of the calcium polysulfide adding rate. When the dosage of calcium polysulfide was 1/8000, the residual zinc concentration was 0.057 mg/L and the removal rate was at about 98.8%. However, when the dose of calcium polysulfide continuously increased, more than 90% of the zinc concentration returned to the aqueous solution. The removal efficiency of copper with a concentration of 5 mg/L by calcium polysulfide was generally not good. The highest removal efficiency occured when the dosage was at the amount of 1/8000 (volume ratio of CaS
x/GW). The residual concentration of copper was at about 2.8 mg/L. We could find that the removal efficiency was only about 45.3%. For cadmium, when the dosage of calcium polysulfide was relatively low, the removal efficiency of cadmium was great. When the dosage of calcium polysulfide was at the amount of 1/20,000 (volume ratio of CaS
x/GW), the removal rate of cadmium was 66.7%. Meanwhile, when the dosages was at the amount of 1/12,000, the removal rate could rise up to 91.1%. However, when the dosage of calcium polysulfide reached 1/8000, the concentration of cadmium was almost completely dissolved again. The removal efficiency of chromium increased regularly with the increase of the calcium polysulfide dosage. When the calcium polysulfide dosage reached the amount of 1/12,000 (volume ratio of CaS
x/GW), the chromium removal rate could reach more than 50%. When the dosage reached the amount of 1/4000, the chromium removal rate was nearly 100%. The removal of chromium was different from nickel, zinc, copper, and cadmium. The adding of excessive calcium polysulfide did not cause the aqueous chromium concentration to rebound.
Figure 6 shows the removal efficiency of calcium polysulfide on various metals at high concentrations (100 mg/L). As for lead, when the dose of calcium polysulfide was at the amount of 1/2000 (volume ratio of CaS
x to GW), the removal rate could reach 87.5%. When the dose was more than the amount of 1/1200, the residual concentration of lead was less than 0.01 mg/L, which means that the removal rate was almost 100%. As the dose of calcium polysulfide continuously increased, the lead concentration in the aqueous did not rebound. The removal efficiency of chromium increased steadily with the increase of the calcium polysulfide dosage. When the dose of calcium polysulfide was at the amount of 1/400 (volume ratio of CaS
x to GW), the chromium removal rate was at about 60%; when the dose was 1/200, the chromium removal rate was at about 87%; when the dose was at the amount of 1/140, the chromium removal rate was nearly 98%; and when the dose reached 1/100, the chromium removal rate could reach 100%.
When the dosage of calcium polysulfide was less than 1/400 (volume ratio of CaSx to GW), the removal efficiency of nickel, zinc, copper, and cadmium was higher than that of chromium. When the dose of calcium polysulfide was at the amount of 1/400 (volume ratio of CaSx/GW), the residual concentration of nickel in the aqueous was about 6.5 mg/L and the removal rate was at about 93.3%. However, as the dose of calcium polysulfide increased continuously, the residual concentration of nickel rose slightly, reaching a maximum concentration of 9.1 mg/L. Although the nickel concentration had rebounded, the removal rate could still reach more than 90%. Zinc also had a minimum residual concentration of 0.03 mg/L when the dosage of calcium polysulfide was at the amount of 1/400 (volume ratio of CaSx/GW) and the removal rate was almost 100%. However, the zinc concentration continued to increase with the increase of the calcium polysulfide dose. When the calcium polysulfide dose was at the amount of 1/200, the zinc concentration was 4.35 mg/L; when the dose was at the amount of 1/100, the zinc concentration was 21.87 mg/L and the re-dissolution rate reached 21.9%. The situation of copper and zinc was similar. When calcium polysulfide was applied at a dosage of 1/400 (volume ratio of CaSx/GW), the residual copper concentration in the solution was 0.223 mg/L, which was the lowest. That is, the removal rate was nearly 100%. However, the copper concentration rebounded quickly. When the calcium polysulfide dosage was increased to 1/200, about 95% of the copper was re-dissolved into the aqueous solution. The removal efficiency of calcium polysulfide to cadmium was higher than that of nickel, zinc, and copper. When the dosage of calcium polysulfide was at the amount of 1/600 (volume ratio of CaSx/GW), the removal rate of cadmium was nearly 100%. Similarly, with the increase of the calcium polysulfide dosage, the concentration of cadmium in the aqueous solution also appeared to be re-dissolved and the rebounded concentration was about 1.65–5.025 mg/L.
Calcium polysulfide had a high removal efficiency for nickel, zinc, copper, and cadmium within an appropriate dosage range and its removal rate was higher than that of chromium. However, when the dosage exceeded the appropriate range, the four metals, which were nickel, zinc, copper, and cadmium, would be re-dissolved in aqueous solution. Lewis et al. [
5,
20] pointed out that the metal sulfide (MS) formed by the reaction of calcium polysulfide and metal may be with HS
− derived from calcium polysulfide in the solution, which formed complexes such as MS(HS)
n−n. Copper was taken as an example, the complexes that could be formed including CuS(HS)
2−2, CuS(HS)
3−3, CuS(S
5)
2−3, Cu(S
4)(S
5)
−3, CuS(S
5)
−2, etc.
Here are the control standards for the four metals in groundwater in Taiwan. It is 1.0 mg/L for nickel; 0.05 mg/L for cadmium; 10 mg/L for copper; 50 mg/L for zinc; 0.5 mg/L for chromium; and 0.1 mg/L for lead. Although calcium polysulfide had a great removal efficiency for nickel, zinc, copper, and cadmium when an appropriate dosage range was applied, for soil and groundwater remediation, due to the heterogeneous characteristics of geology, it was very difficult to accurately deliver the appropriate dosage to the remediation location. It was usually necessary to add excessive amounts of chemicals to ensure that the required dosage was evenly reached. Therefore, in the application of calcium polysulfide in the in situ remediation of groundwater contaminated by nickel, zinc, copper, and cadmium, the re-dissolution concentration may exceed the groundwater control standards and fail to meet the groundwater remediation goals. After long-term monitoring of the precipitate formed by the reaction of calcium polysulfide with chromium and lead, the re-dissolution concentration was very low, notably much lower than the allowable concentration of groundwater. In this study, the precipitates were collected and analyzed by XRD. The chromium precipitate was mainly composed of chromium hydroxide and the lead precipitate was mainly composed of lead sulfide. It was inferred that the chemical reaction formulas of the two metals are Reaction Formula (1) and Reaction Formula (6), respectively.