Next Article in Journal
Watershed Eco-Compensation Mechanism in China: Policies, Practices and Recommendations
Previous Article in Journal
Flood Season Staging and Adjustment of Limited Water Level for a Multi-Purpose Reservoir
 
 
Correction published on 28 June 2023, see Water 2023, 15(13), 2386.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Technical Note

Enhanced Oxygen Volumetric Mass Transfer in a Geometrically Constrained Vortex

by
Luewton L. F. Agostinho
1,2,
Rene Pecnik
3,
Jakob Woisetschläger
4,
Esther de Kroon
1,2,
Nicolae Şişcanu
1,5,
Maarten V. van de Griend
1,6,
Willibald Loiskandl
6 and
Elmar C. Fuchs
1,7,*
1
Wetsus, European Center of Excellence for Sustainable Water Technology, 8911 MA Leeuwarden, The Netherlands
2
Water Technology Research Group, NHL Stenden University of Applied Sciences, Rengerslaan 8-10, 8917 DD Leeuwarden, The Netherlands
3
Process and Energy Laboratory, Delft University of Technology, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands
4
Working Group Metrology-Laser Optical Metrology, Institute for Thermal Turbomachinery and Machine Dynamics, Graz University of Technology, Inffeldgasse 25A, 8010 Graz, Austria
5
Environmental Technology, Wageningen University & Research, Droevendaalsesteeg 4, 6708 PB Wageningen, The Netherlands
6
Institute of Soil Physics and Rural Water Management, University of Natural Resources and Life Sciences, Muthgasse 18, 1190 Vienna, Austria
7
Optical Sciences Group, Faculty of Science and Technology (TNW), University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands
*
Author to whom correspondence should be addressed.
Water 2022, 14(5), 771; https://doi.org/10.3390/w14050771
Submission received: 28 January 2022 / Revised: 22 February 2022 / Accepted: 25 February 2022 / Published: 1 March 2022 / Corrected: 28 June 2023
(This article belongs to the Section Hydraulics and Hydrodynamics)

Abstract

:
Aeration is one of the most cost intensive steps in water and wastewater treatment due to the large energy requirement for the creation of large surfaces for sufficient gas exchange as well as for providing efficient liquid transport in order to exchange saturated liquid elements at the surface with unsaturated ones from the bulk. In this work we show that geometrically constrained vortices in a hyperbolic funnel are a promising aeration technique as they meet these criteria and allow oxygen transfer coefficients up to 50 h 1 , a number significantly higher than that of comparable methods like air jets or impellers (<10 h 1 ).

1. Introduction

Dissolving oxygen in water (aeration) is one of the most energy intensive steps in water and wastewater treatment plants (WWTPs). For example, approximately 54 to 67% of the total energy consumption in WWTPs is used for the aeration of their activated sludge processes to oxidize and remove organic matter (COD) and ammonia (NH3) [1,2,3]. Current aeration technologies applied in large scale for water and wastewater treatment plants range from mixers and impellers to macroscopic orifices or porous materials whose main purpose is to transfer oxygen to a liquid medium [4,5]. Depending on the method, different issues can arise. Fine-pore diffusers suffer from fouling or decrease in aeration efficiency due to scaling and clogging of pores. On the other hand, with coarse-bubble surface aerators and impellers more energy is required to transfer O2 to the liquid media [2].
In industrial processes often swirling flows with highly turbulent liquid–gas interfaces are applied; they overcome some of these disadvantages. Several studies have been performed to understand and characterize the mass transfer across such two-phase interfaces. For example, Duinmeijer et al. [4] used three-dimensional stereo particle image velocimetry to measure the velocity field in the vicinity of the free surface and to investigate the validity of the analytic Burgers vortex model. Kimura et al. [5], Cristofano et al. [6], Putra and Lucas [7] investigated mass transport across the free surface of hydraulic intakes for several applications using numerical analysis and experimental setups. Invisible to the outside observer, there are intricate flow patterns beneath the surface, which only have been recently investigated [8]. These flow patterns are to some extent comparable to so-called “Taylor–Couette” flows, which allow enhanced heat and mass transfer.
In the present work we investigate whether the mass transfer can be further enhanced when swirling flows with liquid–gas interfaces are constrained in a hyperbolic funnel. For example, it has been reported that utilizing a free-surface vortex in a shower head might result in ≈14% lower water consumption while maintaining the shower comfort, higher amounts of oxygen dissolved, and a favourable change in pH if a hyperbolically shaped funnel is used [9]. In this type of funnel, which was first suggested by Schauberger [10], the liquid–gas interface can extend from the top of the funnel all the way to the outlet, resembling a helix or standing wave pattern. It has been hypothesized [10] that a constrained vortex in a hyperbolic funnel can yield extraordinary aeration capabilities. In the present work we have tested this hypothesis by measuring the dissolved oxygen in water after it has been drained in a swirling motion through a hyperbolic funnel. We experimentally observe different liquid–gas interface topologies over a range of mass flow rates, where the highest aeration efficiency is achieved for intermediate mass flows with large liquid– gas interfacial areas. These aeration systems are well defined, highly controllable and extremely efficient aeration systems, with the potential to supersede currently commercially available technologies.

2. Setup and Experimental Methods

The experimental setup with the funnel is shown in Figure 1. The funnel (1) is 94 cm long, has a 30 cm top diameter and a 1.6 cm outlet diameter. On top of the funnel, a glass cylinder (same diameter and 12 cm high) was placed. The water was pumped in the funnel from a ground water well via an inlet port located at the funnel top cylinder. The inlet is engineered such to ensure that the water enters the system tangentially, thus creating a swirl necessary to form the vortex. At the inlet, a flow meter (3, Endress & Hauser Picomag DMA25) was installed to verify the mass flow rate entering the system. Three different parameters were measured at the inlet and outlet: Dissolved oxygen (4, PreSens PSt3 Sensor), pH (5, Endress & Hauser memosens orbisint CPS11D) and redox potential (6, Endress & Hauser memosens orbisint CPS12D). An inlet ball valve (7) and an outlet clamp (9) were installed to balance the mass flow rate to obtain different operating regimes. Upstream of the outlet clamp, a pressure sensor (8, Endress & Hauser Cerabar T PMC131) was installed to verify the system outlet pressure.
The glass structure of the funnel made it possible to visualize the shape of the air–liquid interface. Depending on the operating conditions, three different liquid–air interface shapes were identified, for which the system’s aeration capability was investigated. Each regime was stabilized by controlling the flow inlet and outlet parameters. An outlet dissolved oxygen sensor was used to verify a steady state condition (constant dissolved oxygen concentration). Then dissolved oxygen (DO), pH and redox potential were recorded for 20 min at both inlet and outlet. All the tests were repeated four times, with at least 400 data points per test. The liquid volume was estimated optically assuming rotational symmetry of the hyperboloid with a systematic error of up to ≈5% depending on the flow regime. This calculation was done by first estimating the volume of the air core by digitizing the air/water interface and revolving the obtained curvature around its vertical axis. Since the total inner volume of the system is given by the geometry of the funnel, the liquid volume can be calculated by subtracting the air core from the total volume. The water used for the experiments was ground water. It was analyzed prior to the experiments; the results are summarized in Table 1. Most important characteristics of this water are a low initial oxygen concentration, a relatively high concentration of iron (4.6 mg/L) and a stable pH (6.9).

3. Results

Depending on the mass flow rate through the funnel three types of regimes could be observed which are characterized by distinctively different shapes of the liquid–air interfaces as shown in Figure 2. The restricted regime (Figure 2a) received its denomination due to the fact that a small outlet pressure of around 70 mbar was applied by constricting the outlet tubing. Its surface to volume ratio is low, since the air core does not extend until the outlet. It stops somewhere mid-way and breaks-up into bubbles which float downstream towards the funnel exit (see Figure 2a). The restricted regime forms when the inlet flow is stabilized at approximately 15 L/min. The largest interface to volume ratio is created in the so called twisted regime (Figure 2b). This regime is obtained when no constriction is applied to the outlet valve and the inlet flow is stabilized at approximately 20 L/min. This regime is characterized by a large air volume (around 51% of the total system volume). Another characteristic observed for this regime is the formation of a double helix shaped interface (also seen in Figure 2b). In the straight regime (Figure 2c) the interface to volume ratio is much smaller, around 94% of the total funnel volume is occupied by water. It occurs when the flow is stabilized at approximately 22 L/min and no restriction is applied to the system outlet. In this regime the interface is rather smooth (no double helix shape observed) and it extends until the system outlet.
Table 2 summarizes the different characteristics of each regime regarding their flow rate and outlet pressure. The air volume for each situation was calculated from a visual analysis of the interfaces assuming rotational symmetry. The hydraulic retention time (HRT) was determined by applying tracer technology. A pulse of tracer medium (NaOH, 1 M) was injected at the funnel inlet ( t = 0 ) on fixed time intervals. A short increase in concentration of the tracer was then measured at the funnel outlet using the pH sensor shown in Figure 1 while leaving the system, resulting in an averaged residence time for each pulse. The mean residence time distribution for each pulse was calculated as
T = t i C i C i ,
with t being the mean residence time and C i the concentration of tracer medium in mg/L. The mean residence times of the tracers are equivalent to the HRTs. For each flow regime, these values were compared to and verified by estimated HRTs based on visual analysis. As it can be seen from Table 2 the system has a relatively low HRT. Interestingly, the twisted regime shows the lowest residence times, indicating a delicate force balance between gravitational, centrifugal and friction forces for different mass flow rates. It appears that at intermediate mass flow rates, the swirl and, accordingly, the centrifugal force decrease. Because of the inclined funnel wall, this further results in a lower upward pointing axial force at the funnel wall and thus in lower residence times.
The measurements of the DO allows the calculation of the oxygen volumetric mass transfer coefficient ( K L a ) at 13 ° C and the standard oxygen transfer rate (SOTR), defined as the rate at which the oxygen is transferred in tap water at 20 ° C and zero DO. The oxygen transfer rate, defined as the product of the volumetric mass transfer coefficient K L a (1/h) and a concentration gradient acting as the driving force, is given as [11]
d C d t = K L a C S C ,
with C S being the oxygen saturation concentration and C the actual oxygen concentration in the liquid, both in mg/L. Moreover, the oxygen transfer rate can also be expressed using the oxygen mass balance equation of the overall system, namely as
d C d t = φ V C o u t C i n ,
with φ being the flow rate (L/h) and V the volume (in L) of the liquid contained in the system. Combining Equations (2) and (3), we can then calculate the volumetric mass transfer coefficient as
K L a = φ V ( C o u t C i n ) ( C S C o u t ) ,
which can be easily obtained by the measured quantities during the experiments.
Figure 3 shows that the outlet dissolved oxygen concentration reaches its highest values (≈2 mg/L) inside the twisted regime. This is expected, as this regime presents the largest area-to-volume ratio and also presents a double helix interface which indicates enhanced turbulence, thus also enhanced advection. At a flow rate of 20.8 L/min the outlet DO values obtained for the twisted regime are quite similar compared to those obtained with the straight regime (around 1.5 mg/L). This is due to the fact that at this flow rate the twisted interface is not completely developed, thus the area-to-volume ratio is similar to what is seen in the straight regime. The low DO levels obtained at the restricted regime are due to the small interface area. The outlet redox potential behavior follows the same trend as dissolved oxygen, indicating that oxygen is the dominant oxidation agent in the system. This is expected because the system is fed with anoxic ground water whose analysis did not indicate the presence of other (strong) oxidants (see Table 1). The low (negative) redox values at both inlet and outlet are due to a combination of low dissolved oxygen concentrations and high concentrations of Fe 2 + (see Table 1).
Figure 4 shows K L a and SOTR values (see Supplementary Information for details) dependent also as a function of flow rate. Average K L a values (for 20 °C) for air jet, impellers and paddle aerators [12] are shown for comparison. The plot shows that the K L a values obtained with the free surface vortex in a hyperbolically shaped funnel are considerably higher than those of the three commercial systems used for comparison, especially in the twisted regime. These high oxygen transfer rates are a consequence of the aforementioned combination of high area-to-volume ratios and possibly enhanced turbulence close to the interface. On the other hand, the SOTR values (up to 0.5 kg/h) [12] are comparable to air jet system and lower than those reported for impeller and paddle systems (between 1.0 and 2.5 kg/h) [12]. This is due to the short hydraulic retention times in the hyperbolic funnel (typically less than a minute). A possibility to increase the SOTR value is the application of a cascade of funnels which would multiply the HRT with a factor representing the number of funnels, whilst maintaining the desired flow regime and thus the K L a value. For practical applications the specific energy demand of such a cascade can be estimated as follows: The twisted regime of the hyperbolic funnel tested in this work has a specific energy demand of 0.01 kWh/kg O 2 (see Appendix A for calculation details). In comparison, the specific energy demands of mechanical aerators range from 0.42 to 0.83 kWh/kg O 2 [13] and the specific energy demands of air jets range from 0.74 to 1.0 kWh/kg O 2 [12]. However, the industrial applicability of this system depends on its scalability to higher flow rates in larger funnels on the one hand, and on the possibility to achieve the described regimes with liquids of different viscosities as found in wastewater streams on the other. Thus, while the potential improvements in the energy efficiency of the aeration process seem promising, further work is required for confirmation and to exclude negative impacts on the sludge characteristics and WWTP performances.

4. Conclusions

In summary, we have investigated the potential of a geometrically constricted hyperbolic vortex system for gas diffusion applications. At certain mass flow rates the hydrodynamics of this system provides a large area-to-volume ratio and a large liquid–gas interface with enhanced turbulent mixing near the liquid/gas interface, allowing enhanced gas diffusion and advection superior to commercially available systems.While the system enables very fast gas transfer (high K L a ), it provides a rather limited standard oxygen transfer rate (SOTR). The calculated SOTR is comparable to air jet systems, but lower than those of impellers and paddle wheels. This is caused by the low hydraulic retention time, intrinsic to the hydrodynamics of the system which provides relatively low specific initial angular velocities. However, the SOTR is proportional to the HRT, which again is dependent on the funnel size, thus a larger funnel or several funnels in series could potentially be used for large scale applications like wastewater or drinking water treatment plants. Apart from that, applications like heterogeneous iron removal from ground water [14], which do not necessarily require oxygen saturation, could be a direct application.
In order to better understand the physics behind the enhanced oxygen volumetric mass transfer in this type of geometrically constrained vortex the authors plan to further investigate vortices in constrained systems, including particle image velocimetry and numerical two-phase flow simulations. Stack structured systems would be ideal for large scale applications like wastewater and drinking water treatment plants.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/2073-4441/14/5/771/s1, The calculation method of SOTR values.

Author Contributions

Conceptualization, E.C.F., L.L.F.A., W.L., J.W.; methodology, L.L.F.A., E.C.F., N.Ş., M.V.v.d.G.; validation, L.L.F.A., J.W., R.P., M.V.v.d.G.; investigation, E.d.K., N.Ş., L.L.F.A.; data curation, E.d.K., L.L.F.A.; writing—original draft preparation, E.C.F., L.L.F.A., R.P., J.W., E.d.K., M.V.v.d.G.; writing—review and editing, E.C.F., L.L.F.A., N.Ş., R.P., J.W., W.L., M.V.v.d.G.;visualization, J.W., N.Ş.; supervision, E.C.F., L.L.F.A., J.W., W.L.; project administration, E.C.F.; All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Raw data available from corresponding author upon demand.

Acknowledgments

This work was performed at Wetsus (https://www.wetsus.eu), European Center of Excellence for Sustainable Water Technology. Wetsus is co-funded by the Dutch Ministry of Economic Affairs and Ministry of Infrastructure and Environment, the Province of Fryslân, and the Northern Netherlands Provinces. The authors would like to thank the participants of the research theme “Applied Water Physics” as well as Philipp Kuntke for the fruitful discussions and their financial support.

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A. Specific Energy Demand Calculation

The specific energy demand (kWh/kg O 2 ) was calculated based on the theoretical pump power P p u m p (kW), required for pumping the water, and the Standard Oxygen Transfer Rate (SOTR (kg O 2 /h)) determined in this work. P p u m p (kW) is estimated according to
P p u m p = ρ Q g Δ h α η p u m p η d r i v e = Q Δ p α η p u m p η d r i v e ,
where g is the gravitational acceleration (9.81 m/s 2 ), Q the volumetric flow rate (1.194 m 3 /h based on 19.9 L/min), ρ the density (997 kg/m 3 ), Δ h the height difference (1 m), η p u m p the pump efficiency (0.75), Δ p is the pressure difference over the pump (9780.6 Pa), α is a factor for unit conversion from J to kWh (3.6·10 6 J/kWh), and η d r i v e the drive motor efficiency (0.9). The specific energy demand SE (kWh/kg O 2 ) is then calculated according to
SE = P p u m p SOTR ,
where SOTR is the Standard Oxygen Transfer Rate as determined in this work (0.5 kg O 2 /h at 19.9 L/min). Reported Standard Aeration Efficiencies (SAE) were converted to SE (kWh/kg O 2 ) according to SE = 1 / SAE .

References

  1. Reardon, D.J. Turning down the power. Civ. Eng.—ASCE 1995, 65, 54–56. [Google Scholar]
  2. Rosso, D.; Larson, L.E.; Stenstrom, M.K. Aeration of large-scale municipal wastewater treatment plants: State of the art. Water Sci. Technol. 2008, 57, 973–978. [Google Scholar] [CrossRef] [PubMed]
  3. Åmand, L.; Olsson, G.; Carlsson, B. Aeration control–a review. Water Sci. Technol. 2013, 67, 2374–2398. [Google Scholar] [CrossRef] [PubMed]
  4. Duinmeijer, A.; Oldenziel, G.; Clemens, F. Experimental study on the 3D-flow field of a free-surface vortex using stereo PIV. J. Hydraul. Res. 2020, 58, 105–119. [Google Scholar] [CrossRef]
  5. Kimura, N.; Ezure, T.; Tobita, A.; Kamide, H. Experimental study on gas entrainment at free surface in reactor vessel of a compact sodium-cooled fast reactor. J. Nucl. Sci. Technol. 2008, 45, 1053–1062. [Google Scholar] [CrossRef]
  6. Cristofano, L.; Nobili, M.; Caruso, G. Experimental study on unstable free surface vortices and gas entrainment onset conditions. Exp. Therm. Fluid Sci. 2014, 52, 221–229. [Google Scholar] [CrossRef]
  7. Putra, R.A.; Lucas, D. Modeling of the Free-Surface Vortex-Driven Bubble Entrainment into Water. Water 2020, 12, 709. [Google Scholar] [CrossRef]
  8. Mulligan, S.; De Cesare, G.; Casserly, J.; Sherlock, R. Understanding turbulent free-surface vortex flows using a Taylor–Couette flow analogy. Sci. Rep. 2018, 8, 824. [Google Scholar] [CrossRef] [PubMed]
  9. van de Griend, M.V.; Agostinho, L.L.; Fuchs, E.C.; Dyer, N.; Loiskandl, W. Consequences of the Integration of a Hyperbolic Funnel into a Showerhead for Droplets, Jet Break-Up Lengths, and Physical-Chemical Parameters. Water 2019, 11, 2446. [Google Scholar] [CrossRef]
  10. Radlberger, C. Der hyperbolische Kegel nach Walter Schauberger; PKS Eigenverlag: Bad Ischl, Austria, 2002; ISBN 978-3-950068-61-0. [Google Scholar]
  11. Tribe, L.; Briens, C.; Margaritis, A. Determination of the volumetric mass transfer coefficient (kLa) using the dynamic “gas out–gas in” method: Analysis of errors caused by dissolved oxygen probes. Biotechnol. Bioeng. 1995, 46, 388–392. [Google Scholar] [CrossRef] [PubMed]
  12. Marappan, J.; Ambattaiyanpatti Anathaikamatchi, B.; Sakkarai, S.; Thiagarajan, R.; Muthusamy, D.; Kuppusamy, M.; Moturi, M.; Bera, A.; Ramasamy, P.; Shanmugam, S. Assessment of the new generation aeration systems efficiency and water current flow rate, its relation to the cost economics at varying salinities for Penaeus vannamei culture. Aquac. Res. 2020, 51, 2112–2124. [Google Scholar] [CrossRef]
  13. Tchobanoglous, G.; Burton, F.L.; Stensel, H.D. Wastewater Engineering: Treatment and Reuse; Mcgraw-Hill Series in Civil and Environmental Engineering; McGraw-Hill: Boston, MA, USA, 2003. [Google Scholar]
  14. van Beek, C.; Dusseldorp, J.; Joris, K.; Huysman, K.; Leijssen, H.; F, S.K.; de Vet, W.W.J.M.; van de Wetering, S.; Hof, B. Contributions of homogeneous, heterogeneous and biological iron(II) oxidation in aeration and rapid sand filtration (RSF) in field sites. J. Water Supply: Res. Technol. Aqua 2015, 65, 195–2074. [Google Scholar] [CrossRef]
Figure 1. Sketch of the setup used for the experiments.
Figure 1. Sketch of the setup used for the experiments.
Water 14 00771 g001
Figure 2. Vortex regimes in a hyperbolic funnel from left to right: (a) restricted, (b) twisted, (c) straight.
Figure 2. Vortex regimes in a hyperbolic funnel from left to right: (a) restricted, (b) twisted, (c) straight.
Water 14 00771 g002
Figure 3. Outlet dissolved oxygen and redox potential values for three flows inside each regime.
Figure 3. Outlet dissolved oxygen and redox potential values for three flows inside each regime.
Water 14 00771 g003
Figure 4. Oxygen volumetric mass transfer coefficient K L a values expressed for the “other systems” are K L a 20 and the standard oxygen transfer rate (SOTR) at different flow rates. The calculations assumed the following experimental conditions: T = 13 ° C, P = 1 atm and DO inlet = 0.002 mg/L (see Table 1). The K L a values expressed for the “other systems” are K L a 20 and from Ref. [12].
Figure 4. Oxygen volumetric mass transfer coefficient K L a values expressed for the “other systems” are K L a 20 and the standard oxygen transfer rate (SOTR) at different flow rates. The calculations assumed the following experimental conditions: T = 13 ° C, P = 1 atm and DO inlet = 0.002 mg/L (see Table 1). The K L a values expressed for the “other systems” are K L a 20 and from Ref. [12].
Water 14 00771 g004
Table 1. Characteristics of the ground water used for the experiments.
Table 1. Characteristics of the ground water used for the experiments.
TestResultant ValueUnit
Chloride>800mg/L
Inorganic Carbon (IC)114mg/L
Total Carbon (TC)135mg/L
Total Organic Carbon (TOC)20.4mg/L
Iron4580 μ g/L
Manganese405 μ g/L
Sodium>400mg/L
pH6.9
Dissolved Oxygen (DO)0.002mg/L
Redox Potential−200mV
Temperature13 ° C
Table 2. Characteristics of the different regimes.
Table 2. Characteristics of the different regimes.
RegimeFlow Rate (L/min)
Min/Max
Outlet Pressure (mbar)
Min/Max
Mean Residence Time (s)
Min/Max
Restricted14.7/15.768 /7024/36
Twisted19.9/20.90.0/2.513/23
Straight22.0/23.02.5/5.029/32
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Agostinho, L.L.F.; Pecnik, R.; Woisetschläger, J.; de Kroon, E.; Şişcanu, N.; van de Griend, M.V.; Loiskandl, W.; Fuchs, E.C. Enhanced Oxygen Volumetric Mass Transfer in a Geometrically Constrained Vortex. Water 2022, 14, 771. https://doi.org/10.3390/w14050771

AMA Style

Agostinho LLF, Pecnik R, Woisetschläger J, de Kroon E, Şişcanu N, van de Griend MV, Loiskandl W, Fuchs EC. Enhanced Oxygen Volumetric Mass Transfer in a Geometrically Constrained Vortex. Water. 2022; 14(5):771. https://doi.org/10.3390/w14050771

Chicago/Turabian Style

Agostinho, Luewton L. F., Rene Pecnik, Jakob Woisetschläger, Esther de Kroon, Nicolae Şişcanu, Maarten V. van de Griend, Willibald Loiskandl, and Elmar C. Fuchs. 2022. "Enhanced Oxygen Volumetric Mass Transfer in a Geometrically Constrained Vortex" Water 14, no. 5: 771. https://doi.org/10.3390/w14050771

APA Style

Agostinho, L. L. F., Pecnik, R., Woisetschläger, J., de Kroon, E., Şişcanu, N., van de Griend, M. V., Loiskandl, W., & Fuchs, E. C. (2022). Enhanced Oxygen Volumetric Mass Transfer in a Geometrically Constrained Vortex. Water, 14(5), 771. https://doi.org/10.3390/w14050771

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop