Next Article in Journal
Large-Eddy Simulation of Compound Channels with Staged Floodplains: Flow Interactions and Turbulent Structures
Previous Article in Journal
Analysis of the Effect of Pore Water Pressure on a Small Radius Curve Section of a Fine Sand Layer under Cyclic Metro
Previous Article in Special Issue
Water, Soil, and Plants Interactions in a Threatened Environment
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Comparative Study on the Decontamination Efficacy of Peelable Coatings for Heavy Metals Removal

1
Military Technical Academy “Ferdinand I”, 39-49 George Cosbuc Boulevard, 050141 Bucharest, Romania
2
Faculty of Chemical Engineering and Biotechnologies, University Politehnica Bucharest, 1-7 Gh. Polizu Street, 011061 Bucharest, Romania
3
Research and Innovation Center for CBRN Defense and Ecology, 225 Oltenitei Ave., 041327 Bucharest, Romania
4
Department of Environmental Engineering and Management, Faculty of Chemical Engineering and Environmental Protection, Gheorghe Asachi Technical University of Iasi, 700050 Iasi, Romania
5
National Institute for Research & Development in Chemistry and Petrochemistry ICECHIM, Advanced Polymer Materials and Polymer Recycling Group, Spl. Independentei 202, 6th District, 060021 Bucharest, Romania
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Water 2023, 15(5), 982; https://doi.org/10.3390/w15050982
Submission received: 16 December 2022 / Revised: 20 February 2023 / Accepted: 1 March 2023 / Published: 3 March 2023
(This article belongs to the Special Issue Ecological Risk Assessment of Heavy Metal Pollution)

Abstract

:
This study presents the formulation and application of strippable coatings for the entrapment and removal of heavy metals (HMs) and radio nuclides (RNs). The “green” formulations involve the use of a water-based solution consisting of a synthetic biodegradable polymer, polyvinyl alcohol (PVA), together with a natural polymer (sodium alginate) as the polymer matrix and bentonite as the reinforcing agent with cation exchange capacity. Four chelating agents comprising two classical chelating agents (ethylenediaminetetraacetic acid (EDTA), diethylenetriamine-pentaacetic acid (DPTA)) and two “green” chelating agents (iminodisuccinic acid (IDS), 2-phosphonobutane-1,2,4-tricarboxylic acid (PBTC)) were used to evaluate the capacity to remove Cu, Sb, Zn, Sr, Pb, Co, and Hg from the contaminated surfaces. This decontamination method leads to the formation of a solid waste, thus eliminating the need for wastewater treatment. Atomic absorption spectroscopy (AAS), inductively coupled plasma mass spectrometry (ICP-MS), scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX), and ultraviolet-visible (UV–Vis) spectroscopy were used to comparatively evaluate the decontamination efficacy. EDX elemental mapping confirmed the entrapment of the contaminants inside the polymeric matrix.

1. Introduction

Heavy metals (HMs) and radionuclides (RNs) are among the most dangerous, cytotoxic, mutagenic, and carcinogenic contaminants [1]. Modernization and increased industrial activity have caused an increase in the levels of radioactive and toxic metals in the environment. Significant contamination problems have resulted from using RNs or HMs in various industries including the chemical industry, nuclear industry (e.g., nuclear power plants), extractive industries (e.g., mining activities), medicine (e.g., radiotherapy and diagnosis), or the defense and security industries (e.g., manufacturing and loading of ammunition, explosives, firing shooting ranges). Mining-related RN or HM materials can be present in windblown dust. Inhaling these RNs or HMs from dust harms the cells and tissues. 60Co is utilized for radiotherapy as well as for sterilization processes, while 90Sr is found in the environment due to nuclear reactor waste, but it is also employed in medicine and industry [2,3]. High concentrations of HMs have been found in shooting ranges, or explosives and ammunition factories due to the decomposition of materials such as mercury fulminate, lead azide, lead styphnate, or other explosives found in the composition of primers and detonators [4,5]. In shooting ranges, lead particles as well as dust and fumes from the lead primer and the fragments of bullets are ejected at high pressure from the gun barrel straight next to the shooter [6]. Consequently, small particles settle out around the firing weapon. Some metals released by firing might have particle sizes in the nanoscale range [5,7,8]. The proximal exposure pathway is through inhalation by the shooter of fine Pb particulates, primarily from the primer. Another route for lead exposure is through the fine and coarse particulates that adhere to the shooter’s hands, clothing, and other surfaces from the primer and bullet fragments [6,7]. The utilization of ammunition may also result in high concentrations of other metals and metalloids including copper, antimony, zinc, and arsenic, which could also have adverse health effects [5]. Lead (Pb) and antimony (Sb), two of the metallic components involved, emerge from the bullet, while barium (Ba) and Sb can appear from the primer ignition. Other metals from the case alloys such as copper (Cu), zinc (Zn), and aluminum (Al) are widely used and may result in firing residues. Due to its low environmental abundance, the Sb is thought to be the best firing residue indicator [7].
Thus, anthropogenic RNs and HMs in the environment are mainly related to human activity [9]. Heavy metals can bioaccumulate and enter the food chain because organisms easily absorb them [10]. Eline Vandebroek et al. reported that lead and antimony, both present in ammunition, were found to be in elevated concentrations in the urine and blood of Special Forces staff who participated in weekly shooting training sessions as well as the instructors and maintenance personnel [5]. The central nervous system and kidneys are two organs that may be particularly affected by occupational exposure to mercury (Hg). Skin contact and respiratory systems are potential exposure sources [11].
In the eventuality of contamination incidents, two main paths are involved: detection and identification of the contaminant and decontamination.
For identification of the metallic contaminants, various spectrometric techniques are utilized including FAAS (flame atomic absorption spectrometry), ICP-OES (inductively coupled plasma optical emission spectroscopy), ICP-MS (inductively coupled plasma mass spectrometry), ETA-AS (electrothermal atomic absorption spectrometry), etc. [7]. Many benefits may arise from the sector field inductively coupled plasma mass spectrometer (SF-HR-ICP-MS), which offers a wide dynamic linear range, multi-element evaluation functionality, and remarkably low detection limits [7].
Highly selective detection and UV–VIS monitoring of mercuric ions in aqueous solutions can be achieved by a colorimetric method, which implies the use of a colloidal silver nanoparticle solution (AgNP) [12,13]. The shape of the nanoparticles significantly impacts the absorption and the color of the colloidal solution, potentially influencing the design of new colorimetric sensors [14].
Since long-term exposure to these dangerous materials (RNs or HMs) can cause severe health and safety issues, minimizing the amount of time spent in contaminated areas is imperative. Furthermore, finding a rapid and effective technique to entrap and remove RN and HM contaminants to limit personnel exposure is crucial. The decontamination methods employed for removing RNs and HMs depend on the type of contaminated substrate (e.g., water, soil, solid surfaces, air decontamination, etc.). For the decontamination of solid surfaces, various techniques are available, mainly consisting of washing formulations [15,16]. Even if it may seem to be the most uncomplicated, removing metallic impurities from solid substrates using liquid media [15] and validating the complete removal of the contaminant may prove challenging.
The advantage of using peelable coatings for surface decontamination resides in the generation of solid waste, which reduces secondary cross-contaminations and its elimination is straightforward [17,18,19]. The washing procedures can lead to cross-contaminations and generate larger volumes of waste water that require treatment. Thus, through this method, water serves as a delivery medium for the polymer matrix and chelating agents and by its evaporation, a solid polymer film residue containing the contaminants is formed and no waste water treatment is required.
Poly(vinyl alcohol) (PVA) is a water soluble synthetic polymer that is biodegradable under both aerobic and anaerobic conditions [19,20,21]. PVA is widely used for the fabrication of plastic items and as an additive in the paper, wood, tannery, paint, and coatings industries. Additionally, PVA has found significant application in agriculture related applications where its application leads to disposal in the soil ecosystems [20]. Sodium alginate is a biodegradable polysaccharide polymer obtained from marine brown algae. It is comprised of α-D-mannuronic acid and β-L-guluronic acid units [22,23]. The presence of the carboxyl groups permits the chelation of metal cations and leads to a pH-dependent drug release capacity [24]. Sodium alginate has found application in the food additives [25], cosmetics, pharmaceutic [26], paint, and coatings industries [27].
The aim of this paper consisted of the utilization of multiple analytical methods (including a facile UV–Vis screening method employing silver nanoparticles and SEM-EDX) to demonstrate and evaluate the decontamination efficacy of dual-action innovative water-based strippable coatings designed to remove heavy metal contamination from various types of surfaces from firing ranges or specialized laboratories (indoor shooting ranges floors, walls, targets, workbenches, etc.). These “smart” coatings comprise a water-soluble film-forming polymer, a chelating agent that forms stable complexes with heavy metals/radionuclides, a hydrophilic nanoclay, and a plasticizer that ensures the flexibility required for the exfoliation of the polymeric coating. The nanoclay is an adsorbent for the contaminant and acts as a reinforcing agent for the resulting coating.
Our previous studies described the influence of each distinct component (polymeric matrix, nanoclay, chelating agent) of these formulations on the decontamination performances [4,16,28]. The results were then correlated with the data obtained by AAS and ICP-MS. We showed that the interaction of AgNPs with mercuric ions reduced the UV–Vis signal of the colloidal AgNP solution, allowing the colorimetric detection of mercuric ions and their quantification by monitoring the resulting blue shifts. Finally, the maximum of the AgNP absorbance peak and Hg concentration were found to be linearly and inversely proportional [12] in the range of 2.4 ppm–28.3 ppm Hg, which helps estimate the decontamination efficacy of Hg.
Each analytical method utilized in this study to evaluate the decontamination efficacy of “green” strippable coatings for Cu, Sb, Zn, Sr, Pb, Co, and Hg has its particularities, advantages, and limitations.

2. Materials and Methods

2.1. Materials

Poly(vinyl alcohol) (PVA, 98–99% hydrolysis degree, DP ≈ 1700–1800, Mw ≈ 115,000 Da, Loba Chemie, Mumbai, India), sodium alginate (Alg, Special Ingredients®, Garlenda, Savona, Italy), ethylenediaminetetraacetic acid disodium salt dihydrate (EDTA, for analysis, ACS reagent, Sigma Aldrich, St. Louis, MO, USA), diethylenetriamine-pentaacetic acid calcium trisodium salt hydrate (DTPA, 97.0%, Sigma Aldrich, St. Louis, MO, USA), iminodisuccinic acid (IDS, BAYPURE® CX 100 solid G, Lanxess, Cologne, Germany), 2-phosphonobutane-1,2,4-tricarboxylic acid (PBTC, BAYHIBIT® AM, Lanxess, Cologne, Germany) (see Figure S1 for the chemical structures), bentonite (BT, nanoclay, hydrophilic bentonite, Nanomer® PGV, Sigma Aldrich, St. Louis, MO, USA), glycerol (Gly, anhydrous for synthesis, Sigma Aldrich, St. Louis, MO, USA), silver nitrate (≥99.0%, Sigma Aldrich, St. Louis, MO, USA), tri-sodium citrate dihydrate (Sigma Aldrich, St. Louis, MO, USA), sodium borohydride (≥99.0%, Sigma Aldrich, St. Louis, MO, USA), and mercury(II) chloride (ACS reagent, ≥99.5%, Sigma Aldrich, St. Louis, MO, USA) were used as received. The HAc-NaAc buffer (pH 5.6) was prepared from sodium acetate (ACS reagent, ≥99.0%, Sigma Aldrich, St. Louis, MO, USA) and acetic acid (glacial, ACS reagent, ≥99.7%, Sigma Aldrich, St. Louis, MO, USA).

2.2. Methods

2.2.1. Synthesis

Decontamination Solution Synthesis

The water-based decontamination solutions, designed for the entrapment and removal of heavy metal contaminants, were synthesized through these sequential steps: the first step consisted of the dissolution of the chelating agents (EDTA, DTPA, PBTC, or IDS) in double-distilled water, followed by the dispersion of the hydrophilic bentonite nanoclay with an ultrasonic processor (Sonics® Vibracell VCX750W). The following step consisted of the dissolution of PVA and Alg, at 60 °C, with the aid of a high-speed dispersing instrument (IKA T18 digital ULTRA-TURRAX®) set at 15,000 rpm. The addition of glycerol was the final step, followed by another 30 min of magnetic stirring. Thus, we obtained four distinct decontaminating formulations with the compositions indicated in Table 1.

Silver Nanoparticles (AgNPs) Synthesis

Silver nanoparticles (AgNPs) were prepared according to [13,29]. A trisodium citrate solution (5 wt.%, 2 mL) was added to a silver nitrate solution (0.5 mM AgNO3, 100 mL). This solution was maintained under vigorous stirring with an ultrasonic liquid processor (Sonics, Vibra-cell™, 750 Watts), and a sodium borohydride diluted solution (0.1 wt.%, 2 mL) was subsequently added. The solution was maintained for another 15 min under vigorous stirring (with the above-mentioned ultrasonic liquid processor) and one hour under magnetic stirring at 80 °C. The nanoparticles obtained were stored overnight in a refrigerator (4 °C).

2.2.2. Controlled Contamination Procedure

The working protocol for the controlled contamination followed the basic principles of NATO Standard—AEP-58—Combined operational characteristics, technical specifications, test procedures, and evaluation criteria for chemical, biological, radiological, and nuclear decontamination equipment [30]. Stainless steel coupons were subjected to controlled contamination. Each metallic coupon was contaminated with 1 mL stock solution, placed in the middle of the plate, leading to a uniform distribution due to the wetting properties of the formulation. The stock solution contains a blend of all the heavy metal (HM) solutions: Cu, Sb, Zn, Sr, Pb, Co, and Hg (cHM = 1000 mg/L). Contamination was performed in triplicate for each type of solution. In addition, for the UV–Vis investigations on the efficacy of Hg removal, two supplementary concentrations were employed for contamination (cHg = 2 g/L and cHg = 3 g/L). Sr and Co served as simulants for the radioactive isotopes 90Sr and 60Co. The other metallic species used in this study were selected because they are the most frequently encountered contaminants generated in shooting ranges. The contaminated metallic coupons were placed in an oven (40 °C) overnight.

2.2.3. Decontamination Procedure

Every stainless-steel coupon was placed on a different Petri dish for the decontamination procedure. Successively, the decontamination solution was poured onto the contaminated surface. The decontaminating aqueous formulations covered each metallic plate entirely. The samples were allowed to dry overnight at room temperature. The next day, the strippable nanocomposite coatings obtained were gently removed by peeling. The decontaminated surfaces were subsequently introduced in 100 mL of double-deionized water and placed in an ultrasonic bath for 30 min. These were further subjected to successive dilutions, following the specific requirements of the analytical methods (AAS, ICP-MS, UV–Vis) employed to evaluate the remnant HMs. Experiments were performed in triplicate, and the mean values were reported.

2.2.4. Evaluation of the Decontamination Efficacy

The decontamination efficacy (DEHM[%]) was calculated according to the following formula: DEHM[%] = 100 × (c0 − cf)/c0, where c0 represents the initial concentration of the contaminant placed on the stainless steel coupons and cf stands for the final concentration of HMs found on the decontaminated plate. In addition, the peeled nanocomposite films were subjected to SEM-EDX to demonstrate the presence of the contaminants inside the polymeric film.

3. Results and Discussion

3.1. Basic Principles of HM/RN Decontamination with Nanocomposite Peelable Coatings

Decontamination is defined as the process of removing hazardous materials from contaminated surfaces to reduce local or systemic exposure to a contaminant [31]. Among the existent decontamination methods designed for contaminated surfaces, peelable coatings present multiple advantages in removing the HMs/RNs: they can incorporate chelators, it is an affordable method of decontamination, it is a fast method, the film-forming blends can be easily applied on larges surfaces, they may ensure high decontaminations efficiencies, etc. [32]. Figure 1 explains the basic principles of a decontamination process involving nanocomposite peelable coatings. As illustrated in Figure 1, this decontamination method implies first (1) applying a liquid solution comprising active ingredients on the contaminated surface; (2) allowing it to interact with the contaminants while curing; (3) removing the polymeric film after the complete evaporation of the solvent; (4) re-establishing the operability of the decontaminated surface; and (5) securely disposing of the small amount waste generated by this process.

3.2. Decontamination Mechanism Analysis

In this study, besides the polymeric matrix, bentonite and distinct chelating agents were introduced in the decontamination formulations under investigation. When the chelating agent and the nanoclay were combined in the same decontamination solution, the contaminant was more likely to be retained in the polymeric composite coating due to the following two distinct routes: chemical interaction (complexation) and physical interaction (adsorption), respectively.
The bentonite employed in this study was a hydrophilic layered nanoclay composed of octahedral sheets sandwiched between two tetrahedral silica sheets (Figure 2). Bentonite has a net negative surface charge, which allows for a higher yield of cation removal (Figure 2) [33]. In addition, bentonite was selected for this application because of its small particle sizes and because it possesses one of the largest internal and external surface areas for cation exchange (Figure 2) among mineral clays [33].
Even if bentonite enhances the decontamination efficacy [4], chelating agents are essential [16] in the decontamination of metallic species (HMs or RNs). Figure 3 illustrates a typical complexation scheme executed by one of the chelating agents employed in this study (EDTA). The other chelating agents (DTPA, PBTC, IDS) used in this study exhibited analogous complexation mechanisms (Figure S1).
The chelating ability of sodium alginate is also a factor that may positively influence the decontamination performances. However, the influence of sodium alginate on the decontamination efficacy is still not as visible as the one with the chelating agents or bentonite [29,34]. Nevertheless, the alginate aids by improving the mechanical properties of the peelable film.

3.3. SEM—EDX

SEM-EDX analysis was employed to investigate the morphology of the strippable polymeric nanocomposite films and to evaluate the entrapment of the contaminants (HMs) inside these films. As can be observed from Figure 4, Figure 5, Figure 6, Figure 7 and Figure 8, the nanocomposite polymeric films exhibited a relatively flat surface and a slightly porous inner structure. The EDX mapping revealed the presence of the HM contaminants inside the polymeric matrix. The back-side view shown is the part of the polymeric film, which was in direct contact with the heavy metals, and EDX displayed their homogeneous distribution along the coating. The cross-section view offers evidence of the in-depth entrapment of the contaminants inside the polymeric matrix and also a uniform distribution of the contaminants along the cross-section. Thus, all of the metallic elements captured by the nanocomposite coating were visible in the cross-section view of the EDX-mapping. However, it is worth mentioning that no significant differences in the distribution of the entrapped elements were observed when changing the chelating agents. This means that all the chelating agents were uniformly distributed in the polymer matrix.
Thus, this first type of investigation confirms the entrapment of the contaminants. Still, it is essential to highlight that the SEM-EDX method was only used as a qualitative screening method. The data obtained via SEM-EDX was valuable as an initial stage in this research.

3.4. AAS

Supplementary investigations, with higher accuracy, were further used to quantify the contamination/decontamination efficacies, established following the guidelines in NATO Standard AEP-58 [30]. The concentration of heavy metals before and after decontamination was calculated using atomic adsorption spectrometry (AAS). The decontamination efficacy of each solution for each metal was assessed using the information obtained from the AAS analysis (Figure 9). The concentration of residual metal cations found on the decontaminated surface (Figure 9a) was correlated with the initial concentration of each contaminant, thus obtaining decontamination efficacies in the range of 99.3–99.5% (Figure 9b). According to the AAS results, two of the most notorious heavy metals, lead and mercury, were more efficiently removed by the decontaminating formulations containing EDTA or PBTC. The solution containing DTPA exhibited the lowest decontamination efficiencies though the lowest was still above 99.3%. IDS offered reasonable decontamination efficacies (DE > 99.4%) for all the HM tested. In the case of Sr and Co, the two elements employed as simulants for the 90Sr and 60Co radionuclides, two of the chelating agents, EDTA and IDS, provided the best results for Sr. In contrast, PBTC and IDS supplied the best results for Co.

3.5. ICP-MS

ICP-MS was employed as a complementary investigation to evaluate decontamination efficacy with higher accuracy. AAS is considered less accurate, less beneficial, and extra time-consuming, but far more cost-effective than the ICP-MS technique. AAS is less expensive than ICP-MS, but it can only evaluate the concentration of the elements one by one. To measure multiple atoms, ICP-MS is more accurate, advantageous, faster, and far less time-consuming [35]. However, ICP-MS is not as cost-effective as AAS. Figure 10 illustrates the results obtained from the ICP-MS investigations. The pattern of the decontamination efficiencies was relatively similar for analogous samples, however, higher values for DE were obtained when employing the ICP-MS technique (99.4–99.8%). According to the ICP-MS analysis, for each type of chelating agent used, the decontamination efficiency was the highest for Sr. Almost all of the results obtained via ICP-MS are in accordance with the ones obtained via the AAS technique. Still, few discrepancies appeared for Hg and Pb for DS1-EDTA and DS2-DTPA, respectively.

3.6. Silver Nanoparticles Characterization

Before the UV–Vis investigations, colloidal silver nanoparticles were obtained and characterized. Thus, the formation of spherical nanosized silver particles was confirmed via TEM-EDX analysis (Figure 11).
The color of the colloidal solutions is influenced by the shape and dimension of the nanoparticles [14]. Usually, the mean size of the spherical particles in yellow solutions, with UV–Vis absorbance maxima in the range of 380–420 nm, is approximately 25 nm [14]. TEM analysis revealed that the AgNPs synthesized for the UV–Vis survey described below had a mean diameter of approximately 25 nm.

3.7. UV–Vis

The last analytical technique employed for the comparative evaluation of the decontamination efficacy was UV–Vis spectroscopy. This method implies using a colloidal AgNP solution to quantify the decontamination performances for Hg. UV–Vis is highly selective for Hg detection via AgNPs [13]; thus, the results calculated from the UV–Vis data imply only Hg contamination/decontamination. Therefore, after their synthesis (as described in the Synthesis Section 2.2.1), colloidal AgNPs were subjected to UV–Vis scans, displaying a typical peak around 410 nm. In addition, 300 μL of HAc-NaAc buffer (pH 5.6), an appropriate amount of distilled water, a different volume of Hg solution, and 390 μL of AgNP solution were introduced via a 5 mL centrifuge tube (the combined solution had a total volume of 3 mL). Since Hg (II) ions can interact with the AgNP solution prepared by sodium borohydride, this led to visible changes in the UV–Vis spectra (Figure 12). One explanation could be that the remnant sodium borohydride from the AgNP colloidal solutions could also reduce Hg(II) to Hg (0). These mercury atoms may cover the surface of the silver nanoparticles, generating an aggregate [13], thus leading to a blue shift of the maximum in the UV–Vis peaks (Figure 12 and Figure 13).
Therefore, based on these UV–Vis assays, we intended to find a cost-effective, fast, simple, and highly selective method to evaluate the decontamination efficiency for Hg. The intensity of the AgNP absorption peak observed was interdependent of the concentration of Hg added. Different concentrations of mercury were blended with a constant amount of nanoparticles to obtain an absorption intensity dependent on the Ag nanoparticles versus Hg concentration. A linear and inversely proportional relationship was found between the absorbance intensity of the Ag nanoparticles and the concentration of Hg(II) ions over the range from 2.4 ppm to 28.3 ppm. Thus, this method is not suitable at concentrations of Hg higher than 28 ppm due to the diminution of the AgNP peak until its complete disappearance. Thus, the concentration of Hg in the samples collected from the decontaminated surfaces was established based on the equation (Figure 14) obtained for AgNPs and the association of these data with the UV–Vis maxima shifts.
We only used the DS4-IDS for the UV–Vis survey because this decontaminating formulation demonstrated the ability to remove all the tested HMs efficiently. In addition, IDS ensured high Hg decontamination efficiency. The samples collected from the decontaminated surfaces were mixed with AgNP solutions. The resulting solutions were subsequently subjected to UV–Vis analysis; the data obtained were correlated with the equation describing the dependence of the absorbance of AgNPs with the concentration of Hg, and the results for DE are illustrated in Figure 15. Finally, the decontamination efficacies obtained for Hg were comparable and nearly independent of the initial contamination level.
The entrapment of mercury inside the polymeric matrix was also confirmed via SEM-EDX analysis (Figure 16 and Figure 17). Cross-section EDX elemental mapping (Figure 17) revealed the uniform distribution of the contaminant inside the peeled coating.
Figure 18 summarizes the results obtained for the decontamination formulation DS4-IDS. Compared with the other decontaminating formulations, DS4-IDS demonstrated a remarkable decontamination efficacy for all the HMs tested. Thus, all the samples collected from the surfaces decontaminated with DS4-IDS were analyzed via AAS and ICP-MSA. In addition, the UV–Vis technique was utilized to investigate the Hg-containing samples. In the end, it was shown that each analytical method used for evaluating DE(%) has its particularities, benefits, and constraints.
As it was comparatively shown in Figure 18, the DE(%) values obtained from the ICP-MS analysis were slightly higher than those obtained from AAS, probably due to its higher accuracy. However, one unit lower DE(%) values were obtained with the UV–Vis technique. Thus, we can affirm that each of these three methods can provide fairly accurate results, even if minor differences still exist. The discrepancies probably originate from the different accuracy of each instrument, the interpretation of the results, or sample preparation (successive filtrations, dilutions, human inaccuracies, etc.).
Hg concentrations obtained from the correlation with the blue shift of the AgNP colloidal solutions, monitored via UV–Vis, seems a straightforward method due to the ease of application. Still, its major constraint is that it only applies to Hg [13]. Nevertheless, analytical techniques such as AAS or ICP-MS remain the most viable for other types of heavy metals.
In Figure 18, it can also be easily observed that the DE(%) pattern obtained for Pb and Hg through AAS correlated well with the results obtained from ICP-MS. The differences between the results obtained for DE(%) through AAS vs. ICP-MS were slightly higher for Sb, Zn, Sr, Co, or Cu. However, the outcomes of this study align with the NATO Standards [30,36], which stipulate that the decontamination method applied must lead to a decontamination efficacy of at least 90% to be considered adequate.

4. Conclusions

This study comprises a comparative study that evaluated the decontamination efficacy of four types of "green” strippable coatings for Cu, Sb, Zn, Sr, Pb, Co, and Hg contaminants. EDTA, DTPA, PBTC, and IDS were the chelating agents used to remove the above-mentioned contaminants from the stainless-steel coupons. Controlled contamination was performed first, followed by applying the decontaminating solutions on the contaminated surfaces. These formulations possess the ability to capture the contaminants through adsorption and complexation mechanisms, entrapping them inside the polymeric matrix while curing. After peeling the resulting strippable nanocomposite coatings, the decontaminated surfaces were subjected to an extraction procedure to capture the residual contaminants in an aqueous solution that can be further analyzed via AAS, ICP-MS, or UV–Vis (only for Hg).
Summarizing the results, we can affirm that the classical chelating agents, EDTA and DTPA, ensured higher decontamination efficacies for Hg and Sr, respectively. Moreover, from the two ‘green’ chelating agents employed in this study, PBTC rendered better results for Pb, while IDS seemed to be the only one ensuring high DE(%) values for all the tested contaminants.
Even though the decontamination efficacies obtained through the AAS correlated relatively well with the results obtained from ICP-MS, Hg quantification via UV–Vis based on the blue shift of the AgNP colloidal solutions seems a more straightforward process.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/w15050982/s1, The following supplementary materials include: Material description for AAS and ICP-MS techniques; Figure S1: Chemical structures of the chelating agents used in the study and the description of the characterization methods.

Author Contributions

Conceptualization, G.T. and T.R.; methodology, A.D.; software, E.R.; validation, D.P. and R.E.G.; formal analysis, D.P.; investigation, G.T. and B.T.; data curation, A.I.P.; writing—original draft preparation, A.E.M. and M.G.; writing—review and editing, G.T., A.-M.G. and T.R.; supervision, G.T. All authors have read and agreed to the published version of the manuscript.

Funding

This work was financially granted by the Ministry of Research, Innovation, and Digitalization (UEFISCDI) through PN-III-P1-1.1-PD-2021-0543—ctr.no. PD69/2022 and PN-III-P2-2.1-PED-2021−3415—ctr.no. 672PED/2022. Aurel Diacon gratefully acknowledges financial support from the Competitiveness Operational Program 2014–2020, Action 1.1.3: Creating synergies with RDI actions of the EU’s HORIZON 2020 framework program and other international RDI programs, MySMIS Code 108792, Acronym project “UPB4H”, financed by contract: 250/11.05.2020.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

SEM-EDX, AAS, and ICP-MS analyses were supported by PN-III-P2-2.1-PTE-2021-0403—ctr.no. 102/PTE. Alice Podaru gratefully acknowledges the financial support from the European Social Fund from the Sectoral Operational Program Human Capital 2014–2020 through the Financial Agreement with the title “Training of Ph.D. students and postdoctoral researchers to acquire applied research skills—SMART”; contract no. 13530/16.06.2022—SMIS code: 153734. The authors are grateful to Lanxess for donating the complexing agents PBTC-BAYHIBIT®AM and IDS-BAYPURE®CX 100.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Das, S.; Das, S.; Ghangrekar, M.M. Efficacious bioremediation of heavy metals and radionuclides from wastewater employing aquatic macro- and microphytes. J. Basic Microbiol. 2022, 62, 260–278. [Google Scholar] [CrossRef] [PubMed]
  2. Leonardi, N.M.; Tesán, F.C.; Zubillaga, M.B.; Salgueiro, M.J. Radioactivity Decontamination of Materials Commonly Used as Surfaces in General-Purpose Radioisotope Laboratories. J. Nucl. Med. Technol. 2014, 42, 292. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Liu, S.; He, Y.; Xie, H.; Ge, Y.; Lin, Y.; Yao, Z.; Jin, M.; Liu, J.; Chen, X.; Sun, Y.; et al. A State-of-the-Art Review of Radioactive Decontamination Technologies: Facing the Upcoming Wave of Decommissioning and Dismantling of Nuclear Facilities. Sustainability 2022, 14, 4021. [Google Scholar] [CrossRef]
  4. Toader, G.; Stănescu, P.-O.; Zecheru, T.; Rotariu, T.; El-Ghayoury, A.; Teodorescu, M. Water-based strippable coatings containing bentonite clay for heavy metal surface decontamination. Arab. J. Chem. 2019, 12, 4026–4034. [Google Scholar] [CrossRef] [Green Version]
  5. Vandebroek, E.; Haufroid, V.; Smolders, E.; Hons, L.; Nemery, B. Occupational Exposure to Metals in Shooting Ranges: A Biomonitoring Study. Saf. Health Work. 2019, 10, 87–94. [Google Scholar] [CrossRef]
  6. Laidlaw, M.A.; Filippelli, G.; Mielke, H.; Gulson, B.; Ball, A.S. Lead exposure at firing ranges—A review. Environ. Health 2017, 16, 1–15. [Google Scholar] [CrossRef] [Green Version]
  7. Diaz, E.; Souza Sarkis, J.E.; Viebig, S.; Saldiva, P. Measurement of airborne gunshot particles in a ballistics laboratory by sector field inductively coupled plasma mass spectrometry. Forensic Sci. Int. 2012, 214, 44–47. [Google Scholar] [CrossRef]
  8. Bai, J.; Zhao, X. Ecological and Human Health Risks of Heavy Metals in Shooting Range Soils: A Meta Assessment from China. Toxics 2020, 8, 32. [Google Scholar] [CrossRef]
  9. Wojtkowska, M.; Wojtkowski, K.; Długosz-Lisiecka, M. Assessment of Heavy Metals and Radionuclides Concentration in Selected Mineral Waters Available on the Polish Market. Appl. Sci. 2022, 12, 11401. [Google Scholar] [CrossRef]
  10. Custodio, M.; Fow, A.; Chanamé, F.; Orellana-Mendoza, E.; Peñaloza, R.; Alvarado, J.C.; Cano, D.; Pizarro, S. Ecological Risk Due to Heavy Metal Contamination in Sediment and Water of Natural Wetlands with Tourist Influence in the Central Region of Peru. Water 2021, 13, 2256. [Google Scholar] [CrossRef]
  11. Shirkhanloo, H.; Golbabaei, F.; Hassani, H.; Eftekhar, F.; Kian, M.J. Occupational Exposure to Mercury: Air Exposure Assessment and Biological Monitoring based on Dispersive Ionic Liquid-Liquid Microextraction. Iran. J. Public Health 2014, 43, 793–799. [Google Scholar] [PubMed]
  12. Ahmed, M.A.; Hasan, N.; Mohiuddin, S. Silver Nanoparticles: Green Synthesis, Characterization, and Their Usage in Determination of Mercury Contamination in Seafoods. ISRN Nanotechnol. 2014, 2014, 148184. [Google Scholar] [CrossRef] [Green Version]
  13. Wu, L.P.; Zhao, H.W.; Qin, Z.H.; Zhao, X.Y.; Pu, W.D. Highly Selective Hg (II) Ion Detection Based on Linear Blue-Shift of the Maximum Absorption Wavelength of Silver Nanoparticles. J. Anal. Methods Chem. 2012, 2012, 856947. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Velgosova, O.; Mačák, L.; Čižmárová, E.; Mára, V. Influence of Reagents on the Synthesis Process and Shape of Silver Nanoparticles. Materials 2022, 15, 6829. [Google Scholar] [CrossRef] [PubMed]
  15. Johansson, I.; Somasundaran, P. Handbook for Cleaning/Decontamination of Surfaces; Elsevier Science: Amsterdam, The Netherlands, 2007. [Google Scholar]
  16. Pulpea, D.; Rotariu, T.; Toader, G.; Pulpea, G.B.; Neculae, V.; Teodorescu, M. Decontamination of radioactive hazardous materials by using novel biodegradable strippable coatings and new generation complexing agents. Chemosphere 2020, 258, 127227. [Google Scholar] [CrossRef]
  17. Lewandowski, K.; Krepski, L.R.; Mickus, D.E. Dry-peelable temporary protective coatings from waterborne self-crosslinkable sulfourethane–silanol dispersions. J. Appl. Polym. Sci. 2004, 91, 1443–1449. [Google Scholar] [CrossRef]
  18. Wagle, P.G.; Tamboli, S.S.; More, A.P. Peelable coatings: A review. Prog. Org. Coat. 2021, 150, 106005. [Google Scholar] [CrossRef]
  19. Xue, Y.; Yang, W.; Yue, R.; Chen, Y. Aqueous Strippable Polymer Coating for Highly Efficient Primary Radioactive Uranium Decontamination with Versatility on Diversified Surface. Polymers 2022, 14, 1656. [Google Scholar] [CrossRef]
  20. Chiellini, E.; Corti, A.; D’Antone, S.; Solaro, R. Biodegradation of poly (vinyl alcohol) based materials. Prog. Polym. Sci. 2003, 28, 963–1014. [Google Scholar] [CrossRef]
  21. Alonso-López, O.; López-Ibáñez, S.; Beiras, R. Assessment of Toxicity and Biodegradability of Poly(vinyl alcohol)-Based Materials in Marine Water. Polymers 2021, 13, 3742. [Google Scholar] [CrossRef]
  22. Ahmad, A.; Mubarak, N.M.; Jannat, F.T.; Ashfaq, T.; Santulli, C.; Rizwan, M.; Najda, A.; Bin-Jumah, M.; Abdel-Daim, M.M.; Hussain, S.; et al. A Critical Review on the Synthesis of Natural Sodium Alginate Based Composite Materials: An Innovative Biological Polymer for Biomedical Delivery Applications. Processes 2021, 9, 137. [Google Scholar] [CrossRef]
  23. Sun, J.; Tan, H. Alginate-Based Biomaterials for Regenerative Medicine Applications. Materials 2013, 6, 1285–1309. [Google Scholar] [CrossRef]
  24. Azar, A.T. Modeling and Control of Drug Delivery Systems; Elsevier Science: Amsterdam, The Netherlands, 2021. [Google Scholar]
  25. Additives, E.P.O.; Bampidis, V.; Azimonti, G.; Bastos, M.D.L.; Christensen, H.; Dusemund, B.; Fašmon Durjava, M.; Kouba, M.; López-Alonso, M.; Marcon, m.; et al. Safety and efficacy of a feed additive consisting of sodium alginate for all animal species (ALGAIA). EFSA J. 2022, 20, e07164. [Google Scholar] [CrossRef]
  26. Wang, M.; Chen, L.; Zhang, Z. Potential applications of alginate oligosaccharides for biomedicine–A mini review. Carbohydr. Polym. 2021, 271, 118408. [Google Scholar] [CrossRef]
  27. Gaggero, G.; Delucchi, M.; Di Tanna, G.; Lagazzo, A.; Vicini, S.; Botter, R. Effect of different alginate salts on the rheological and tensile properties of waterborne paints. Prog. Org. Coat. 2022, 163, 106676. [Google Scholar] [CrossRef]
  28. Toader, G.; Pulpea, D.; Rotariu, T.; Diacon, A.; Rusen, E.; Moldovan, A.; Podaru, A.; Ginghină, R.; Alexe, F.; Iorga, O.; et al. Strippable Polymeric Nanocomposites Comprising “Green”; Chelates, for the Removal of Heavy Metals and Radionuclides. Polymers 2021, 13, 4194. [Google Scholar] [CrossRef]
  29. Toader, G.; Diacon, A.; Rotariu, T.; Alexandru, M.; Rusen, E.; Ginghină, R.E.; Alexe, F.; Oncioiu, R.; Zorila, F.L.; Podaru, A.; et al. Eco-Friendly Peelable Active Nanocomposite Films Designed for Biological and Chemical Warfare Agents Decontamination. Polymers 2021, 13, 3999. [Google Scholar] [CrossRef]
  30. NATO. AEP-58-Combined Operational Characteristics, Technical Specifications, Test Procedures, and Evaluation Criteria for Chemical, Biological, Radiological, and Nuclear Decontamination Equipment; NATO. 2014. Available online: https://standards.globalspec.com/std/14358280/aep-58-vol-1 (accessed on 15 December 2022).
  31. Chilcott, R.P. Managing mass casualties and decontamination. Environ. Int. 2014, 72, 37–45. [Google Scholar] [CrossRef]
  32. Gossard, A.; Lilin, A.; Faure, S. Gels, coatings and foams for radioactive surface decontamination: State of the art and challenges for the nuclear industry. Prog. Nucl. Energy 2022, 149, 104255. [Google Scholar] [CrossRef]
  33. Alexander, J.A.; Ahmad Zaini, M.A.; Surajudeen, A.; Aliyu, E.-N.U.; Omeiza, A.U. Surface modification of low-cost bentonite adsorbents—A review. Part. Sci. Technol. 2019, 37, 538–549. [Google Scholar] [CrossRef]
  34. Rotariu, T.; Pulpea, D.; Toader, G.; Rusen, E.; Diacon, A.; Neculae, V.; Liggat, J. Peelable Nanocomposite Coatings: “Eco-Friendly” Tools for the Safe Removal of Radiopharmaceutical Spills or Accidental Contamination of Surfaces in General-Purpose Radioisotope Laboratories. Pharmaceutics 2022, 14, 2360. [Google Scholar] [CrossRef] [PubMed]
  35. Carter, J.A.; Barros, A.I.; Nóbrega, J.A.; Donati, G.L. Traditional Calibration Methods in Atomic Spectrometry and New Calibration Strategies for Inductively Coupled Plasma Mass Spectrometry. Front. Chem. 2018, 6, 504. [Google Scholar] [CrossRef] [PubMed]
  36. NATO, AEP-7 - Chemical, Biological, Radiological and Nuclear (CBRN) Contamination Survivability Factors in the Design, Testing and Acceptance of Military Equipment; NATO. 2012. Available online: https://standards.globalspec.com/std/9857648/AEP-7 (accessed on 15 December 2022).
Figure 1. Basic principles of a decontamination process involving nanocomposite peelable coatings.
Figure 1. Basic principles of a decontamination process involving nanocomposite peelable coatings.
Water 15 00982 g001
Figure 2. Cation exchange steps: (1) Bentonite before hydration; (2) swelling of bentonite; (3) hydration of the exchangeable cations; (4) the contaminant replaces the interlayer exchangeable cations.
Figure 2. Cation exchange steps: (1) Bentonite before hydration; (2) swelling of bentonite; (3) hydration of the exchangeable cations; (4) the contaminant replaces the interlayer exchangeable cations.
Water 15 00982 g002
Figure 3. Schematic illustration of the interaction of the heavy metal cation and EDTA chelating agent.
Figure 3. Schematic illustration of the interaction of the heavy metal cation and EDTA chelating agent.
Water 15 00982 g003
Figure 4. SEM-EDX survey of the strippable coating (DS4) after removal (back-side view). (a) SEM image of the peeled coating; (b) EDX mapping of the peeled coating; (c) energy dispersive X-ray analysis (EDX) spectrum.
Figure 4. SEM-EDX survey of the strippable coating (DS4) after removal (back-side view). (a) SEM image of the peeled coating; (b) EDX mapping of the peeled coating; (c) energy dispersive X-ray analysis (EDX) spectrum.
Water 15 00982 g004
Figure 5. EDX mapping of the elements entrapped inside the polymeric strippable coating DS4 (back-side view).
Figure 5. EDX mapping of the elements entrapped inside the polymeric strippable coating DS4 (back-side view).
Water 15 00982 g005aWater 15 00982 g005b
Figure 6. SEM image of the peeled coating (DS4, cross-section view) employed for Cu, Sb, Zn, Sr, Pb, and Co decontamination.
Figure 6. SEM image of the peeled coating (DS4, cross-section view) employed for Cu, Sb, Zn, Sr, Pb, and Co decontamination.
Water 15 00982 g006
Figure 7. SEM-EDX survey of the strippable coating (DS4) after removal (cross-section view): (a) SEM image of the peeled coating; (b) EDX mapping of the peeled coating; (c) energy dispersive X-ray analysis (EDX) spectrum.
Figure 7. SEM-EDX survey of the strippable coating (DS4) after removal (cross-section view): (a) SEM image of the peeled coating; (b) EDX mapping of the peeled coating; (c) energy dispersive X-ray analysis (EDX) spectrum.
Water 15 00982 g007
Figure 8. EDX mapping of the elements entrapped inside the polymeric strippable coating (DS4, cross-section).
Figure 8. EDX mapping of the elements entrapped inside the polymeric strippable coating (DS4, cross-section).
Water 15 00982 g008aWater 15 00982 g008b
Figure 9. AAS assessment of the decontamination efficiency.
Figure 9. AAS assessment of the decontamination efficiency.
Water 15 00982 g009
Figure 10. ICP-MS assessment of the decontamination efficiency.
Figure 10. ICP-MS assessment of the decontamination efficiency.
Water 15 00982 g010
Figure 11. Silver nanoparticles (AgNPs)—TEM image and EDX spectrum.
Figure 11. Silver nanoparticles (AgNPs)—TEM image and EDX spectrum.
Water 15 00982 g011
Figure 12. UV–VIS for the AgNP colloidal solutions—blue-shift with the gradual addition of Hg: (1) 0 ppm Hg; (2) 1.18 ppm Hg; (3) 2.37 ppm Hg; (4) 4.71 ppm Hg; (5) 7.08 ppm Hg; (6) 9.45 ppm Hg; (7) 23.67 ppm Hg; (8) 25.87 ppm Hg; (9) 28.28 ppm Hg; (10) 30.69 ppm Hg; (11) 32.89 ppm Hg; (12) 33.10 ppm Hg; (13) 35.30 ppm Hg.
Figure 12. UV–VIS for the AgNP colloidal solutions—blue-shift with the gradual addition of Hg: (1) 0 ppm Hg; (2) 1.18 ppm Hg; (3) 2.37 ppm Hg; (4) 4.71 ppm Hg; (5) 7.08 ppm Hg; (6) 9.45 ppm Hg; (7) 23.67 ppm Hg; (8) 25.87 ppm Hg; (9) 28.28 ppm Hg; (10) 30.69 ppm Hg; (11) 32.89 ppm Hg; (12) 33.10 ppm Hg; (13) 35.30 ppm Hg.
Water 15 00982 g012
Figure 13. Image illustrating the color change in accordance with the absorption spectra of AgNPs in the absence and the presence of Hg(II) (1) 0 ppm Hg; (2) 1.18 ppm Hg; (3) 2.37 ppm Hg; (4) 4.71 ppm Hg; (5) 7.08 ppm Hg; (6) 9.45 ppm Hg; (7) 23.67 ppm Hg; (8) 25.87 ppm Hg; (9) 28.28 ppm Hg; (10) 30.69 ppm Hg; (11) 32.89 ppm Hg; (12) 33.10 ppm Hg; (13) 35.30 ppm Hg.
Figure 13. Image illustrating the color change in accordance with the absorption spectra of AgNPs in the absence and the presence of Hg(II) (1) 0 ppm Hg; (2) 1.18 ppm Hg; (3) 2.37 ppm Hg; (4) 4.71 ppm Hg; (5) 7.08 ppm Hg; (6) 9.45 ppm Hg; (7) 23.67 ppm Hg; (8) 25.87 ppm Hg; (9) 28.28 ppm Hg; (10) 30.69 ppm Hg; (11) 32.89 ppm Hg; (12) 33.10 ppm Hg; (13) 35.30 ppm Hg.
Water 15 00982 g013
Figure 14. Correlation between the intensity of AgNPs absorbance and Hg concentration.
Figure 14. Correlation between the intensity of AgNPs absorbance and Hg concentration.
Water 15 00982 g014
Figure 15. Decontamination efficacies of Hg obtained via UV–Vis.
Figure 15. Decontamination efficacies of Hg obtained via UV–Vis.
Water 15 00982 g015
Figure 16. SEM image of the peeled coating (a) cross-section view (b) top view employed for Hg decontamination.
Figure 16. SEM image of the peeled coating (a) cross-section view (b) top view employed for Hg decontamination.
Water 15 00982 g016
Figure 17. EDX mapping of Hg entrapped inside the polymeric strippable coating (cross-section view).
Figure 17. EDX mapping of Hg entrapped inside the polymeric strippable coating (cross-section view).
Water 15 00982 g017
Figure 18. Comparative evaluation between the AAS, ICP-MS, and UV–Vis results regarding DS4-IDS decontamination efficacy DE(%).
Figure 18. Comparative evaluation between the AAS, ICP-MS, and UV–Vis results regarding DS4-IDS decontamination efficacy DE(%).
Water 15 00982 g018
Table 1. Formulation of the decontamination solutions".
Table 1. Formulation of the decontamination solutions".
Sample CodeChelating Agent [wt.%]PVA [wt.%]Alg [wt.%]BT [wt.%]Gly [wt.%]
DS1—EDTA150.713
DS2—DTPA150.713
DS3—PBTC150.713
DS4—IDS150.713
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Toader, G.; Pulpea, D.; Diacon, A.; Rusen, E.; Ginghina, R.E.; Rotariu, T.; Podaru, A.I.; Moldovan, A.E.; Gavrilescu, M.; Gavrila, A.-M.; et al. Comparative Study on the Decontamination Efficacy of Peelable Coatings for Heavy Metals Removal. Water 2023, 15, 982. https://doi.org/10.3390/w15050982

AMA Style

Toader G, Pulpea D, Diacon A, Rusen E, Ginghina RE, Rotariu T, Podaru AI, Moldovan AE, Gavrilescu M, Gavrila A-M, et al. Comparative Study on the Decontamination Efficacy of Peelable Coatings for Heavy Metals Removal. Water. 2023; 15(5):982. https://doi.org/10.3390/w15050982

Chicago/Turabian Style

Toader, Gabriela, Daniela Pulpea, Aurel Diacon, Edina Rusen, Raluca Elena Ginghina, Traian Rotariu, Alice Ionela Podaru, Andreea Elena Moldovan, Maria Gavrilescu, Ana-Mihaela Gavrila, and et al. 2023. "Comparative Study on the Decontamination Efficacy of Peelable Coatings for Heavy Metals Removal" Water 15, no. 5: 982. https://doi.org/10.3390/w15050982

APA Style

Toader, G., Pulpea, D., Diacon, A., Rusen, E., Ginghina, R. E., Rotariu, T., Podaru, A. I., Moldovan, A. E., Gavrilescu, M., Gavrila, A. -M., & Trica, B. (2023). Comparative Study on the Decontamination Efficacy of Peelable Coatings for Heavy Metals Removal. Water, 15(5), 982. https://doi.org/10.3390/w15050982

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop