Apparent Quality and Service Performance Evaluation of SCFFC in Tunnel Secondary Lining

School of Civil Engineering, Guizhou University, Guiyang 550025, China
*
Author to whom correspondence should be addressed.
Buildings 2022, 12(4), 479; https://doi.org/10.3390/buildings12040479
Submission received: 16 March 2022 / Revised: 8 April 2022 / Accepted: 11 April 2022 / Published: 12 April 2022
(This article belongs to the Collection Advanced Concrete Materials in Construction)

Abstract

:
After removing the mold from the secondary lining concrete of a tunnel, problems such as honeycomb and hemp surface easily occur. To obtain self-compacting fair-faced concrete (SCFFC) that can meet strength requirements and effectively solve the above problems, this research prepared SCFFC with different mix proportions and performed slump expansion, slump, J-ring expansion and mechanical tests. Additionally, this research comprehensively analyzed the SCFFC based on fuzzy mathematics to study its apparent quality and service performance. This research aimed to solve problems such as uneven bubbles and poor bubble diameter in C30 SCFFC, through a combination of defoaming and air entraining by adding defoamer and air-entraining agent according to different proportions for compound treatment. The defoamer dosage was 0.5‰ of that of water reducer, and the air-entraining agent dosage was 0.1‰ of that of cement. The workability and clearance passability of the concrete were optimal. At the same time, the apparent holes in the SCFFC were small, as were their area and quantity. The distribution and apparent color of the SCFFC were uniform. Considering the factors affecting the service performance of concrete and after a comprehensive analysis of the samples’ weights, subjection degree, variability, stability, and strength index, this research found that the ratio for obtaining a C30 SCFFC material with the highest apparent quality and service performance was as follows: cement:machine-made sand:crushed dtone:fly-ash:water = 4:8.6:9.3:1:2.2. The water reducer comprised 1.0% of the total mass of the cementitious materials. The defoamer dosage was 0.5‰ of that of water reducer, and the dosage of air-entraining agent was 0.1‰ of that of cement.

1. Introduction

With the continuous improvement in basic transportation infrastructure around the world, the construction mileage of highways and high-speed railways has increased rapidly. However, traffic routes must traverse many mountains and hills. As a result, bridges and tunnels account for a large proportion of traffic engineering. In the process of tunnel construction, in addition to needing to grasp the mechanical properties of the rock mass of the site, engineers must also consider the supporting structure. The supporting structure of a tunnel is composed of the primary support and secondary lining. Ideally, the primary support bears all the stress transmitted by the surrounding rock, however in reality, after the tunnel excavation, the surrounding rock is deformed and the primary support is squeezed. When the self-supporting capacity of the primary support and surrounding rock reaches its limit, the tunnel’s secondary lining begins to bear the load. The secondary lining is the last barrier of the tunnel’s supporting structure. At the same time, it is also the most intuitive means for most people to judge whether a tunnel is in a safe or poor state [1,2,3,4].
In recent years, tunnel construction engineers, experts and scholars have paid more attention to tunnels’ primary supports. However, they have conducted less research on the service performance and apparent quality of secondary lining materials, especially in the process of tunnel construction in the water-rich karst mountain areas. Typically, when tunnel excavation is completed, the primary support wall is built immediately. However, due to the large amount of water in the rock surrounding the tunnel construction site, the primary support is damaged. Then, a large amount of water seepage occurs in the lining, as shown in Figure 1 [5,6]. At this time, the main treatment measure used on most project sites is to adopt temporary sprayed concrete for plugging and then creating the tunnel’s secondary lining. Even if a waterproof layer is set up between the secondary lining and the primary support, moisture will still seep into the secondary lining due to the excessive amount of water. If the secondary lining is composed of an ordinary concrete material, under the action of a large amount of water, the water seeps through the concrete, carries away the relevant chemicals from the concrete, and then precipitates a large number of crystals attached to the lining surface (as shown in Figure 2), which inevitably affect its mechanical properties. During tunnel operation, if water seeps through the secondary lining and falls onto the road surface, it poses a hidden danger [7,8]. In addition, if ordinary concrete is used for the tunnel secondary lining material, after concrete pouring is finished, the surface of the concrete is prone to honeycombing or hemp surface (as shown in Figure 3). In order to improve the apparent quality of the secondary lining, a modified secondary lining trolley must be used to “reprocess” it, as shown in Figure 4 [9]. This process not only prolongs the construction process and is expensive, but most importantly, the secondary lining will have many defects, which will impact its overall stress effect. Therefore, the authors studied the service performance and apparent quality of a tunnel secondary lining concrete material and identified the main factors affecting its service performance and apparent quality, which are of practical significance for tunnel engineering.
Based on the above purpose, the authors prepared a concrete material that meets service requirements and has high apparent quality—self-compacting fair-faced concrete (SCFFC). SCFFC is a new type of green concrete that combines the advantages of self-compacting concrete (SCC) and fair-faced concrete (FFC). Its advantages are its compactness, ability to pass through gaps, fluidity, less vibration and easy construction. In addition, after removing the mold, the concrete has a smooth surface, few defects and a uniform color. As the filling material of a tunnel’s secondary lining, SCFFC can reduce the need for later modification, reduce the need for human and material resources, and reduce the project cost.
Scholars worldwide have conducted considerable research on concrete and achieved successful results. For example: Jayanth et al. added steel fiber to the concrete, and the strength of the concrete increases under the cyclic load, which can effectively restrain the crack width and expansion caused by the concrete failure. They were concerned with the mechanical strength and failure forms of concrete [10]. Wang et al. described the composition and properties of steel-fiber-reinforced concrete in detail and studied the main causes of catastrophes involving the lining after service, but they only focused on the mechanical performance and overall stability of the tunnel lining structure [11]. Abbas and Nehdi were the first to explore the application of mixed-steel-fiber UHPC with different particle sizes in a prefabricated segment of tunnel lining, so that the mechanical properties and component size reductions in tunnel linings were improved [12]. Sangiorgi adopted the experimental design method of the mixture, produced 12 sets of concrete with different mixture ratios, and optimized the mix ratio. He found that adding waste silt to the concrete would not affect the workability of the concrete, and the water absorption of the concrete would be affected by the casting process. However, he only studied the physical and mechanical properties of the concrete and did not study the apparent quality [13]. An et al. studied a shallow-buried rectangular tunnel under vibration load, took fiber-reinforced concrete as a lining structure material, and used finite element software to analyze the seismic performance of the secondary lining structure [14]. Based on the indoor mechanical test results of fiber-reinforced concrete, Belyakov et al. used numerical simulation to study the damage caused to fiber-reinforced concrete used as an underground roadway and as the tunnel lining of a structure under dynamic load [15]. Sheikh and Saif studied the application of steel-fiber-reinforced concrete in the lining of a diversion tunnel. By comparing the use effect of other traditional conventional reinforced concrete linings, they analyzed the construction cost, construction speed, and lining structure stability of steel-fiber-reinforced concrete [16]. Cugat et al. applied fiber-reinforced concrete as a tunnel lining and evaluated the reliability of that lining structure, considering material characteristics and material variability in the actual scale structure [17]. Xu et al. developed the fiber-reinforced coal gangue-based geopolymer concrete (FRCGGPC). They found that the splitting tensile strength of FRCGGPC with steel fiber (SF) and polyester fiber (PF) was higher than that of FRCGGPC with basalt fiber. The fiber combines closely with the coal gangue, which enhances the strength of the matrix material. However, when the amount of fiber is too large, it will reduce the mechanical properties of concrete. The researchers focused on the mechanical properties of concrete, however, they did not study the working and apparent properties of concrete [18]. Based on the thick-walled cylinder theory, Wang et al. developed a new pressure-resistant concrete material suitable for hydraulic tunnel linings with high water pressure. They conducted tests on the pressure-resistant concrete lining and evaluated its effectiveness [19]. Based on the mechanical response law of concrete under seismic intensity, Xin et al. conducted a series of shaking table tests on ordinary, reinforced and polypropylene-fiber-reinforced concrete as tunnel secondary lining structures to explore whether polypropylene-fiber-reinforced concrete can effectively reduce the seismic response strength and benefit structural stability [20]. Alaloul et al. used fly ash instead of part of cementitious material, rubber powder instead of part of fine aggregate, and silica fume to prepare a new type of SCC. They changed the mix ratio, prepared 13 SCC specimens, and analyzed their mechanical properties [21]. Magbool and Zeyad added five different types of 1% steel fiber and 0.2% hybrid steel fiber (a mixture of all steel fiber types) to concrete to prepare a new SCC. They studied the working and mechanical properties of different types of steel fiber on fresh concrete. At the same time, they found that steel fiber improved the hardening property and toughness index of SCC [22]. Hilal et al. added different proportions of eggshell ash and three kinds of waste plastic fibers to concrete to prepare high-strength self-compacting concrete. They studied the workability and 7-day, 28-day and 90-day compressive and flexural strength of high-strength self-compacting concrete [23]. Kumar et al. replaced 15% cement with fly ash and 15% cement with slag powder to prepare SCC. They added different contents of nano-material-graphene oxide to SCC to improve the strength and toughness of cement-based composites and obtained high strength self-compacting concrete. They aimed to improve the mechanical properties of concrete, however, they did not study the apparent quality of hardened concrete [24]. They all prepare SCC by adding different substitute materials to concrete. Then, its working properties and mechanical properties are studied. Chang et al. simulated the sulfate resistance of FFC and the effect of sulfate on concrete surface quality under sulfate erosion and actual marine environment. They found that sulfate corrodes the surface morphology of FFC. They focused on the changes in the apparent morphology of FFC in a specific environment. They did not delve into the mechanical properties of concrete [25]. In previous studies on tunnel secondary lining concrete materials, scholars have mainly studied the mechanical strength of composite concrete, the influence of vibration load on the secondary lining structure, the damage characteristics of the concrete, and so on. Few researchers have focused on the filling performance and apparent quality of concrete. In particular, research on the combined advantages of SCC and FFC is sparse, and the main factors affecting the service performance and apparent quality of concrete have not been identified.
Therefore, this research took SCFFC as our research object, performed a multiangle analysis, and based on the theory of fuzzy mathematics and through processing the SCFFC test data, quantified each influencing factor to reveal the main factors affecting the service performance and apparent quality of SCFFC. This paper contributes to the research on concrete materials and provides theoretical support and data that can be referenced for the design and construction of secondary tunnel linings.

2. Sample Preparation

This research conducted the test scheme adopted in this study in full accordance with “Technical specification for application of fair-faced concrete” and “Technical specification for application of self-compacting concrete”. The authors obtained the concrete specimens used in the test by mixing cement, machine-made sand, crushed stone, fly ash, admixture and water according to different proportions. First, this research conducted the J-ring and slump tests on the mixed concrete. After determining the relevant parameters, the authors poured concrete into the mold (as shown in Figure 5). Finally, the authors formed the concrete into cube specimens with sides 150 mm long. This research made twelve groups of six specimens, for a total of seventy-two specimens. After analyzing the apparent quality statistics of the concrete specimens, this research conducted uniaxial compression and shear tests. The related experiments in this paper were carried out in the Yanlou PC Factory of the Guizhou Branch of China Construction Technology Group Co., Ltd. This research determined the optimal proportions for the secondary tunnel lining concrete based on the test results [26,27,28,29,30].

3. Factors Controlling Apparent Quality and Service Performance of SCFFC

Our main purpose in this research was to study the apparent quality and service performance of a secondary tunnel lining concrete material. C30 concrete is mostly used in secondary tunnel linings. Therefore, this research used C30 SCFFC for our research. Factory experimenters have rich experience in concrete preparation. Based on their suggestion, this research selected the following SCFFC preparation materials. After a large amount of preparatory work in the early stage of the test, the cement in the raw material of C30 SCFFC was adapted to match Guizhou Linshan PO42.5 cement (its physical and chemical indices are shown in Table 1) to eliminate the color difference on the surface of concrete caused by the addition of mineral admixture to the concrete. The fly ash used was Class F II fly ash produced by Guizhou Huadian Tangzhai Power Generation Co., Ltd. Its performance index is shown in Table 2. The fine aggregate sand used was the same batch of machine-made sand. The fineness modulus was 2.6 and the gradation range was zone II. For the coarse aggregate stone, this research used stones with better grain shape, qualified gradation, and particle sizes within the range 5–20 mm. The admixtures included water reducer, defoamer, and an air-entraining agent. This research used a polycarboxylic acid water reducer, which had little effect on the color of the concrete. Its solid content was 30%, and the water reduction rate was 35%.
To improve the apparent quality and service performance of the SCFFC, this research examined the effect of adding defoamer and an air-entraining agent to the concrete. The authors propose the combination of defoaming and air-entraining to solve problems affecting the quality of concrete, such as uneven bubbles and poor bubble diameters. To reduce the bleeding segregation and improve the workability of the concrete in the process of concrete mixing, the authors used a Degusai polyether air-entraining agent to introduce a large number of uniformly distributed, stable, and closed microbubbles into the concrete. Its content was between 0.005% and 0.015% of the weight of the cement. To quickly reduce the surface tension of the material and the surface strength, elasticity, and viscosity of the liquid film, for the defoamer, the authors used organosilicon. Its content was 0.01–0.1% of the weight of the water reducer.
Through the preliminary preparation test, this research obtained the mixture ratio of the C30 SCFFC. The authors conducted J-ring and slump tests on the mixed concrete. Then, this research poured the mixed concrete the molds with side lengths of 150 mm and obtained the test specimens after curing (as shown in Figure 6). Next, the authors analyzed statistics on the quality and apparent defects of each specimen, and finally conducted uniaxial compression and shear test for each specimen. After a statistical analysis of the relevant performance parameters of SCFFC, this research obtained the mixture ratio for C30 SCFFC that can simultaneously guarantee the self-compactness and clear water effect of concrete. Finally, the basic concrete material was adopted in the mix ratio shown in Table 3.

3.1. Statistics of Slump Expansion, Slump and J-Ring Expansion of SCFFC

The authors mixed the concrete based on Table 3. In order to test the water retention, fluidity, cohesion, and passing quality through gaps in the SCFFC, this research selected test instruments that met industry standards. These included a slump cone, concentric hard square nonabsorbent plate, J-ring, measuring tools, scrapers, etc. First, the slump test was carried out on the SCFFC (see Figure 7). In the first step, the authors wet the concentric hard square nonabsorbent plate and the slump cone, and placed the slump cone in the center of the former, and fixed it. In the second step, the authors filled the slump cone with the mixed and unhardened concrete. In the third step, the authors used a scraper to scrape the concrete to the same plane as the upper edge of the slump cone while cleaning up the surrounding concrete residue. During the whole test process, it did not need to be vibrated. In the fourth step, the authors lifted the slump cone vertically, uniformly and quickly to 300 mm above the original position of the top mouth of the slump cone, taking no more than two seconds. In the fifth step, the authors measured and counted the maximum vertical slump height and lateral maximum expansion of the concrete. Secondly, in the process of concrete expansion, the authors needed to count the time (T500) when the slump expansion reached 500 mm. Finally, the authors carried out the J-ring expansion test on the SCFFC (see Figure 8). In the first step, the authors wet the concentric hard square nonabsorbent plate, slump cone, and J-ring, and placed the J-ring in the center of the concentric hard square nonabsorbent plate. The authors positioned the slump cone upside down and concentric with the J-ring. In the second step, the authors filled inverted slump cone with the mixed and unhardened concrete. In the third step, the authors used a scraper to scrape the concrete to the same plane as the upper edge of the slump cone and simultaneously cleaned up the surrounding concrete residue. During the whole test process, it did not need to be vibrated. In the fourth step, the authors lifted the slump cone vertically, uniformly, and quickly to 300 mm above the original position of the top mouth of the slump cone, taking no more than two seconds. In the fifth step, the authors measured and counted the expansion of the concrete.
The SCFFC slump extension, slump and J-ring expansion test results are shown in Figure 9. The statistics of the SCFFC T ¯ 500 are shown in Figure 10. According to the requirements of the SCFFC criterion, the slump extension of concrete with first-class filling ability is 550–650 mm, where T500 is not less than two seconds. For concrete with first-class passing quality through gaps, the subtractive value of slump expansion and J-ring expansion is in the range 25–50 mm. Through analysis of the test data, this research found that the SCFFC’s first-class filling ability was 83.33%, and its first-class rate of passing quality through gaps was 75%. The test results showed that the fluidity, cohesion, and passing quality through gaps of the concrete mix ratio outlined in this paper effectively reached the standards of high-class SCFFC. When the amount of defoamer was constant, with an increase in air-entraining agent, the slump extension and J-ring expansion of the concrete gradually increased, the slump and expansion time fluctuated, and the fluctuation range was small. When the amount of air-entraining agent was constant, with an increase in defoamer, the slump extension, slump, and J-ring expansion of the concrete increased at first and then decreased, and the slump expansion time decreased at first and then increased. Therefore, the defoamer and air-entraining agent must be added and combined according to certain proportions to optimize the workability and passing quality through gaps in the concrete. For this purpose, considering the test data, this research suggests a defoamer dosage of 0.5‰ of that of the water reducer and a dosage of air-entraining agent of 0.1‰ of that of cement.

3.2. Statistics of Apparent Quality Parameters of SCFFC

For the maintained SCFFC, the authors took pictures of each surface of the specimens. These photos were imported into Image-pro-plus 6.0 software for gray-scale processing, and then the SCFFC’s surface holes were statistically analyzed by the software, as shown in Figure 11. The main parameters of SCFFC apparent quality statistics are apparent hole number, apparent hole area, and color uniformity. This research obtained statistical results for the apparent defect density and color uniformity coefficient, as shown in Figure 12. The test results, showed that the effects of adding defoamer and air-entraining agent on the apparent hole number, apparent hole area, and color uniformity of the concrete fluctuated. This phenomenon lacked regularity, and the authors could only find a better proportion from many proportions. When the defoamer dosage was 0.5‰ of that of water reducer and the dosage of air-entraining agent was 0.1‰ of that of cement, the apparent holes in the SCFFC were small, as were their area and quantity. The distribution and apparent color of the SCFFC were uniform. This showed that, with this ratio, the apparent quality of SCFFC was higher, and the occurrences of honeycomb and hemp surface were fewer.

4. Calculation of SCFFC Strength Index

Our purpose in this study was to evaluate the strength of SCFFC under the influence of multiple factors. In this study, the authors took the concrete strength index (CSI) as the basis for a comprehensive evaluation of the mechanical properties of concrete. The larger the CSI, the stronger the influence on the mechanical properties of the concrete. As the authors still did not know the most important factor affecting the strength of concrete, in the process of evaluating the influencing factors, the authors chose the coefficient of variation method. This method enables the determination of the internal index weights of each constituent element [31,32,33]. The specific calculation process is as follows:
C V j = Δ j X ¯ j ( j = 1 , 2 , n )
In Equation (1), CVj is the coefficient of variation in the jth index; ∆j is the standard deviation in the jth index; X ¯ j is the average of the jth controlling factor.
W j = C V j j = 1 n C V j ( j = 1 , 2 , n )
In Equation (2), Wj is the weight of the jth index.
C S I = Q i × W i ( j = 1 , 2 , n )
In Equation (3), Qi is the membership degree of the jth index.
According to Equations (1)–(3), to determine CSI, the authors first need to select the concrete strength index; second, determine each weight index; and the third, establish the membership degree function.
(1)
Selection of the concrete strength index: the uniaxial compressive strength and shear strength of concrete were taken as the evaluation indices of concrete strength, and these two strength values could be obtained by a uniaxial compression test and direct shear test of the concrete.
(2)
Determination of the weight of each index: the authors analyzed the influences of various control factors on the strength indices of the concrete and determined the weight value of each index.
(3)
Establishment of the membership degree function and the calculation of the membership degree: the membership degree function was constructed to establish the mathematical expression between the concrete strength control factors and the strength indices. The ultimate goal was to convert the index values of different dimensions into dimensionless values between zero and one. The higher the degree of membership of a single index, the stronger its impact. The authors used the following formula to calculate the membership degrees of the uniaxial compressive strength and shear strength of the concrete.
Q X = 1.0 X > X 2 0.1 + 0.9 X X 1 X 2 X 1 X 1 X X 2 0.1 X 1 > X
In Equation (4), X1 is the lower critical value of the concrete strength index and X2 is the upper critical value of the concrete strength index.
The authors determined the lower and upper critical values of the SCFFC strength index by performing mechanical tests (as shown in Figure 13). The test results are shown in Figure 14. The upper and lower critical values of each strength index are shown in Table 4.

4.1. Comprehensive Strength Verification and Significance Test of SCFFC

The strength of SCFFC widely fluctuates under the influence of various factors. Therefore, the authors selected three indices, average strength value ( X ¯ ), coefficient variation (CV) and stabilization coefficient (SC), to characterize the comprehensive strength of SCFFC. SC was calculated according to the following formula:
S C = X ¯ j Δ σ σ M A X X ¯ j Δ τ τ M A X
In Equation (5), ∆σ is the standard deviation of the SCFFC compressive strength. ∆τ is the standard deviation of the SCFFC shear strength. σMAX is the maximum compressive strength of the SCFFC. τMAX is the maximum shear strength of the SCFFC. Equation (5) illustrates that when ∆σ and ∆τ are larger, the CV is larger and the SC is lower.
The authors used SPSS to analyze the variance of the test data and test its significance based on the Duncan method. The results are shown in Table 5, which shows that the additional amounts of defoamer and air-entraining agent, the apparent hole number, and the apparent defect density had substantial effects on the strength of the concrete.

4.2. SCFFC Comprehensive Strength Evaluation

The authors substituted the data in Table 5 into Equations (1), (2) and (4). The authors calculated the weight and average membership degree of each index that affected the uniaxial compressive strength and shear strength of the SCFFC, as shown in Table 6 and Table 7. The authors also constructed a radar chart based on the data in Table 6 and Table 7 (see Figure 15). Our analysis of the radar chart showed that the weight values of the influencing factors of uniaxial compression strength and shear strength were as follows: Apparent defect density ˃ Apparent hole density ˃ Dosage of air entraining agent ˃ Dosage of defoamer. These results suggest that the apparent defect density of SCFFC was the most important factor affecting its comprehensive strength. However, the average membership degrees of the influencing factors of uniaxial compression strength were as follows: Dosage of defoamer ˃ Dosage of air entraining agent = Apparent defect density ˃ Apparent hole density. These results demonstrate that the apparent hole density was not the main factor affecting the strength of SCFFC. This research comprehensively analyzed the weights and membership degrees of SCFFC compressive strength and shear strength, and preliminarily determined that the apparent defect density was the main factor affecting the strength of SCFFC. To prove this, this research further analyzed the variabilities, stabilities and strength comprehensive indices of the factors influencing SCFFC strength.
The authors substituted the data obtained in this study into Equations (3) and (5) to obtain, the SCs and CSIs of the influencing factors (see Table 8). The radar chart in Figure 16 illustrates the CVs, SCs and CSIs of the factors affecting the intensity of SCFFC. The authors comparatively analyzed the factors influencing CV, SC and CSI, and finally determined the most important factor affecting the strength of SCFFC. Table 9 and Table 10 show the results of the comparative analysis. After analyzing Table 9 and Table 10, this research found the CV and CSI of the effect of apparent defect density on the uniaxial compressive strength of SCFFC were ranked the largest, and the SC was ranked the lowest. The results show that the apparent defect density had the widest variability, the highest stability, and the strongest influence on the comprehensive strength index among the factors influencing the uniaxial compressive strength of SCFFC. The SC of the effect of the defoamer addition on the shear strength of SCFFC was ranked the largest, and the CV and CSI were ranked the lowest. The results show that the defoamer had low variability, high stability and a weak influence on the comprehensive strength index among the factors influencing the shear strength of SCFFC. Although the defoamer had an influence on the shear strength, it cannot be regarded as the most disadvantageous factor. However, the CV and CSI of the effect of apparent defect density on the shear strength of SCFFC were ranked the largest, and the SC was ranked the lowest. The results show that the apparent defect density had the widest variability, the highest stability, and the strongest influence on the comprehensive strength index among the factors influencing the shear strength of SCFFC. Therefore, this research determined that the apparent defect density was the most important factor affecting the strength of SCFFC.
Our purpose in this study was to solve problems such as honeycomb and hemp surface that occur in the process of filling a secondary tunnel lining with concrete. After our comparative study on the service performance and apparent quality of each concrete material ratio, this research concluded that the C30 SCFFC material with the highest apparent quality and service performance had the following ratio: Cement:Machine-made Sand:Crushed Stone:Fly-ash:Water = 4:8.6:9.3:1:2.2. The water reducer was 1.0% of the total mass of cementitious materials, the defoamer dosage was 0.5‰ of that of water reducer and the dosage of air-entraining agent was 0.1‰ of that of cement.

5. Conclusions

(1)
The combination of defoaming and air-entraining, by adding the defoamer and air-entraining agent according to different proportions for compound treatment, can solve the problems of uneven bubbles and poor bubble diameter in C30 SCFFC. It can simultaneously ensure that C30 SCFFC has sufficient water retention, fluidity, cohesion, passing quality through gaps, etc. The authors conducted experiments on SCFFC fabricated according to the mix ratio specified in this paper. After analyzing the data on slump expansion, slump, and J-ring expansion, this research concluded that the SCFFC’s first-class rate of filling-ability was 83.33%, and its first-class rate of passing quality through gaps was 75%. The test results show that the concrete fabricated according to the mix ratio given in this paper effectively reached the standard of high-class SCFFC.
(2)
When the amount of defoamer was constant, with an increase in air-entraining agent, the slump extension and J-ring expansion of the concrete gradually increased, the slump and expansion time fluctuated, and the fluctuation range was small. When the amount of air-entraining agent was constant, with an increase in defoamer, the slump extension, slump, and J-ring expansion of the concrete increased at first and then decreased, and the slump expansion time decreased at first and then increased. Considering this and the test data, this research concluded that when the defoamer dosage is 0.5‰ of that of the water reducer, and the dosage of air-entraining agent is 0.1‰ of that of cement, the workability and passing quality through gaps of concrete are the highest.
(3)
The effects of the addition of defoamer and air-entraining agent on the apparent hole number, apparent hole area, and color uniformity of the concrete fluctuated. This phenomenon lacked regularity, and this research could only find a better proportion from among many proportions. However, this result also reflected that the additions of defoamer and air-entraining agent influenced the quality of the concrete, and the additional amounts of both must be strictly controlled. When the defoamer dosage is 0.5‰ of that of the water reducer and the dosage of air-entraining agent is 0.1‰ of that of the cement, the apparent holes in the SCFFC are small, as were their area and quantity. The distribution and apparent color of the SCFFC are uniform.
(4)
This research found that the additional amounts of defoamer and air entraining agent, the apparent hole number and apparent defect density have remarkable effects on the strength of the concrete. Uniaxial compression tests and direct shear tests are conducted on concrete specimens with different mix ratios. This research also performed a comprehensive analysis of the weight, subjection degree, variability, stability, and strength index of the influencing factors based on fuzzy mathematics. This research found that the C30 SCFFC material with the highest apparent quality and service performance has the following ratio: Cement:Machine-made Sand:Crushed Stone:Fly-ash:Water = 4:8.6:9.3:1:2.2. The water reducer is 1.0% of the total mass of the cementitious materials. The defoamer dosage is 0.5‰ of that of the water reducer, and the dosage of the air-entraining agent is 0.1‰ of that of cement. The self-compacting fair-faced concrete prepared according to the above ratio meets the strength requirements and solves problems such as honeycomb and hemp surface in the filling process of secondary tunnel lining concrete.

Author Contributions

Writing—original draft, C.X.; writing—review and editing, T.T.; Data curation, K.H. All authors have read and agreed to the published version of the manuscript.

Funding

The Science and Technology Planning Project of Guizhou Province (Grant Nos. [2020]2Y036).

Institutional Review Board Statement

All participants gave written informed consent in accordance with the Declaration of Helsinki. Ethical approval was not required for this study in accordance with the national and institutional guidelines.

Informed Consent Statement

Informed consent was obtained from all participants involved in the study.

Data Availability Statement

Data is contained within the article.

Acknowledgments

This paper is sponsored by the Science and Technology Planning Project of Guizhou Province (Grant Nos. [2020]2Y036).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Rankoth, C.K.; Hosoda, A.; Iwama, K. Modeling and Verification of Early Age Thermal Stress in Second Lining Concrete of NATM Tunnels. J. Adv. Concr. Technol. 2017, 15, 213–226. [Google Scholar] [CrossRef] [Green Version]
  2. Wang, R.Y.; Yan, Q.Q.; Tian, B.; Xie, J.D. Effect of Moisture Content and Fiber on the High-Temperature Properties of Tunnel Second Lining Concrete. J. Highw. Transp. Res. Dev. 2015, 9, 63–68. [Google Scholar] [CrossRef]
  3. Lukic, D.C.; Zlatanovic, E.M.; Jokanovic, I.M. Tunnel lining load with consideration of the rheological properties of rock mass and concrete. Geomech. Eng. 2020, 21, 53–62. [Google Scholar] [CrossRef]
  4. Lu, C.C.; Hwang, J.H. Damage analysis of the new Sanyi railway tunnel in the 1999 Chi-Chi earthquake: Necessity of second lining reinforcement. Tunn. Undergr. Space Technol. 2018, 73, 48–59. [Google Scholar] [CrossRef]
  5. Fang, Y.; Guo, J.; Grasmick, J.; Mooney, M. The effect of external water pressure on the liner behavior of large cross-section tunnels. Tunn. Undergr. Space Technol. Inc. Trenchless Technol. Res. 2016, 60, 80–95. [Google Scholar] [CrossRef]
  6. Zhou, Y.; Su, K.; Wu, H. Hydro-mechanical interaction analysis of high pressure hydraulic tunnel. Tunn. Undergr. Space Technol. Inc. Trenchless Technol. Res. 2015, 47, 28–34. [Google Scholar] [CrossRef]
  7. Russo, N.; Gastaldi, M.; Marras, P.; Schiavi, L.; Strini, A.; Lollini, F. Effects of load-induced micro-cracks on chloride penetration resistance in different types of concrete. Mater. Struct. 2020, 53, 143. [Google Scholar] [CrossRef]
  8. Cuenca, E.; Rigamonti, S.; Gastaldo Brac, E.; Ferrara, L. Crystalline Admixture as Healing Promoter in Concrete Exposed to Chloride-Rich Environments: Experimental Study. J. Mater. Civ. Eng. 2021, 33, 040204911. [Google Scholar] [CrossRef]
  9. Zhang, Y.; Yuan, M.; Liu, C.; Zhang, X.; Yang, B.; Yang, J. Repairing Damaged Tunnel Lining with Small-Size Cavity in Surrounding Rocks. J. Perform. Constr. Facil. 2021, 35, 06021002. [Google Scholar] [CrossRef]
  10. Jayanth, K.; Prakash, M.N.; Suresh, G.S.; Naveen, B.O. Studies on the behaviour of steel fibre-reinforced concrete under monotonic and repeated cyclic stress in compression. Arch. Civ. Mech. Eng. 2022, 22, 50. [Google Scholar] [CrossRef]
  11. Wang, X.; Fan, F.; Lai, J.; Xie, Y. Steel fiber reinforced concrete: A review of its material properties and usage in tunnel lining. Structures 2021, 34, 1080–1098. [Google Scholar] [CrossRef]
  12. Abbas, S.; Nehdi, M.L. Mechanical Behavior of Ultrahigh-Performance Concrete Tunnel Lining Segments. Materials 2021, 14, 2378. [Google Scholar] [CrossRef] [PubMed]
  13. Solouki, A.; Tataranni, P.; Sangiorgi, C. Mixture Optimization of Concrete Paving Blocks Containing Waste Silt. Sustainability 2022, 14, 451. [Google Scholar] [CrossRef]
  14. An, D.; Chen, Z.; Cui, G. Research on Seismic Performance of Fiber Concrete Lining Structure of Urban Shallow-Buried Rectangular Tunnel in Strong Earthquake Area. KSCE J. Civ. Eng. 2021, 25, 2378. [Google Scholar] [CrossRef]
  15. Belyakov, N.; Smirnova, O.; Alekseev, A.; Tan, H. Numerical Simulation of the Mechanical Behavior of Fiber-Reinforced Cement Composites Subjected Dynamic Loading. Appl. Sci. 2021, 11, 1112. [Google Scholar] [CrossRef]
  16. Sheikh, K.A.; Saif, A. Steel Fibre-Reinforced Shotcrete as an alternative to conventional concrete tunnel lining: A case study of Gulpur Hydropower Project. Geomech. Geoengin. 2020, 15, 252–262. [Google Scholar] [CrossRef]
  17. Cugat, V.; Cavalaro, S.H.P.; Bairán, J.M.; de la Fuente, A. Safety format for the flexural design of tunnel fibre reinforced concrete precast segmental linings. Tunn. Undergr. Space Technol. Inc. Trenchless Technol. Res. 2020, 103, 103500. [Google Scholar] [CrossRef]
  18. Xu, Z.; Wu, J.; Zhao, M.; Bai, Z.; Wang, K.; Miao, J.; Tan, Z. Mechanical and microscopic properties of fiber-reinforced coal gangue-based geopolymer concrete. Nanotechnol. Rev. 2022, 11, 526–543. [Google Scholar] [CrossRef]
  19. Wang, X.; Liu, L.; Fu, R.; Sun, X. Newly developed pressure adaptable concrete lining for high pressure hydraulic tunnels. Tunn. Undergr. Space Technol. Inc. Trenchless Technol. Res. 2020, 105, 103570. [Google Scholar] [CrossRef]
  20. Xin, C.L.; Wang, Z.Z.; Zhou, J.M.; Gao, B. Shaking table tests on seismic behavior of polypropylene fiber reinforced concrete tunnel lining. Tunn. Undergr. Space Technol. Inc. Trenchless Technol. Res. 2019, 88, 1–15. [Google Scholar] [CrossRef]
  21. Alaloul, W.S.; Musarat, M.A.; Haruna, S.; Law, K.; Tayeh, B.A.; Rafiq, W.; Ayub, S. Mechanical Properties of Silica Fume Modified High-Volume Fly Ash Rubberized Self-Compacting Concrete. Sustainability 2021, 13, 5571. [Google Scholar] [CrossRef]
  22. Magbool, H.M.; Zeyad, A.M. The effect of varied types of steel fibers on the performance of self-compacting concrete modified with volcanic pumice powder. Mater. Sci.-Pol. 2021, 39, 172–187. [Google Scholar] [CrossRef]
  23. Hilal, N.; Al Saffar, D.M.; Ali, T.K.M. Effect of egg shell ash and strap plastic waste on properties of high strength sustainable self-compacting concrete. Arab. J. Geosci. 2021, 14, 291. [Google Scholar] [CrossRef]
  24. Kumar, B.N.; Abhilash, B.; Naveen Kumar, C.H.; Pavan, S. Effect of Nano Materials on Performance Characteristics of High Strength Self Compacting Concrete. Assian Res. Assoc. 2021, 2, 26–35. [Google Scholar] [CrossRef]
  25. Honglei, C.; Zuquan, J.; Penggang, W.; Jianhong, W.; Jian, L. Comprehensive resistance of fair-faced concrete suffering from sulfate attack under marine environments. Constr. Build. Mater. 2021, 277, 122312. [Google Scholar] [CrossRef]
  26. Zhang, H.; Zhang, J.; Yang, Y.; Hu, Q.; He, Y.; Wei, P. Effects of asphalt emulsion on the durability of self-compacting concrete. Constr. Build. Mater. 2021, 292, 123322. [Google Scholar] [CrossRef]
  27. Grinys, A.; Balamurugan, M.; Augonis, A.; Ivanauskas, E. Mechanical Properties and Durability of Rubberized and Glass Powder Modified Rubberized Concrete for Whitetopping Structures. Materials 2021, 14, 2321. [Google Scholar] [CrossRef]
  28. Gnanaraj, S.C.; Chokkalingam, R.B.; Thankam, G.L.; Pothinathan, S.K.M. Influence of Steatite and Fly Ash on the Fresh-Hardened Properties and Micromorphology of Self-Compacting Concrete. Adv. Mater. Sci. Eng. 2021, 2021, 6627450. [Google Scholar] [CrossRef]
  29. Belebchouche, C.; Moussaceb, K.; Bensebti, S.E.; Aït-Mokhtar, A.; Hammoudi, A.; Czarnecki, S. Mechanical and Microstructural Properties of Ordinary Concrete with High Additions of Crushed Glass. Materials 2021, 14, 1872. [Google Scholar] [CrossRef]
  30. Khoshkbijari, R.K.; Samimi, M.F.; Mohammadi, F.; Talebitaher, P. Effects of Mica and Feldspar as partial cement replacement on the rheological, mechanical and thermal durability of self-compacting mortars. Constr. Build. Mater. 2020, 263, 120149. [Google Scholar] [CrossRef]
  31. Yang, X.C.; Ye, H.C.; Li, D.M.; Yu, X.C.; Liu, K.L.; Hu, Q.P.; Hu, Z.H.; Gu, Z.H.; Hu, H.W.; Zhou, L.J.; et al. Assessment of red soil upland fertility in long-term fertilization based on fuzzy mathematics and principal component analysis. Soil Fertil. Sci. China 2018, 3, 79–84. (In China) [Google Scholar] [CrossRef]
  32. Terenchuk, S.; Yeremenko, B.; Kartavykh, S.; Nasikovskyi, O. Application of fuzzy mathematics methods to processing geometric parameters of degradation of building structures. EUREKA Phys. Eng. 2018, 1, 56–62. [Google Scholar] [CrossRef]
  33. Kuzyakov, O.N.; Kolosova, A.L.; Andreeva, M.A. System for corrosion monitoring in pipeline applying fuzzy logic mathematics. J. Phys. Conf. Ser. 2018, 1015, 052017. [Google Scholar] [CrossRef]
Figure 1. Seepage and leakage of tunnel lining.
Figure 1. Seepage and leakage of tunnel lining.
Buildings 12 00479 g001
Figure 2. Precipitated crystal of tunnel lining.
Figure 2. Precipitated crystal of tunnel lining.
Buildings 12 00479 g002
Figure 3. Tunnel second lining defect.
Figure 3. Tunnel second lining defect.
Buildings 12 00479 g003
Figure 4. Tunnel second lining modified trolley.
Figure 4. Tunnel second lining modified trolley.
Buildings 12 00479 g004
Figure 5. Preparation process of concrete specimen.
Figure 5. Preparation process of concrete specimen.
Buildings 12 00479 g005
Figure 6. Part of the test specimens.
Figure 6. Part of the test specimens.
Buildings 12 00479 g006
Figure 7. SCFFC slump test.
Figure 7. SCFFC slump test.
Buildings 12 00479 g007
Figure 8. SCFFC J-ring expansion test.
Figure 8. SCFFC J-ring expansion test.
Buildings 12 00479 g008
Figure 9. Statistics of apparent quality parameters of SCFFC.
Figure 9. Statistics of apparent quality parameters of SCFFC.
Buildings 12 00479 g009
Figure 10. Statistical results of SCFFC T ¯ 500 .
Figure 10. Statistical results of SCFFC T ¯ 500 .
Buildings 12 00479 g010
Figure 11. Apparent defect statistics of SCFFC.
Figure 11. Apparent defect statistics of SCFFC.
Buildings 12 00479 g011
Figure 12. Statistical results of apparent quality parameters of SCFFC. (a) Statistical results of apparent hole number and apparent hole area. (b) The number of specimens with uniform apparent color.
Figure 12. Statistical results of apparent quality parameters of SCFFC. (a) Statistical results of apparent hole number and apparent hole area. (b) The number of specimens with uniform apparent color.
Buildings 12 00479 g012
Figure 13. SCFFC mechanical test.
Figure 13. SCFFC mechanical test.
Buildings 12 00479 g013
Figure 14. Mechanical strength of SCFFC.
Figure 14. Mechanical strength of SCFFC.
Buildings 12 00479 g014
Figure 15. Radar chart of weight and average membership degree of each index of SCFFC strength.
Figure 15. Radar chart of weight and average membership degree of each index of SCFFC strength.
Buildings 12 00479 g015
Figure 16. Radar chart of SC and CSI of each index of SCFFC strength.
Figure 16. Radar chart of SC and CSI of each index of SCFFC strength.
Buildings 12 00479 g016
Table 1. Guizhou Linshan PO42.5 cement physical and chemical indexes.
Table 1. Guizhou Linshan PO42.5 cement physical and chemical indexes.
Density
/g∙cm−3
Specific Surface Area
/m2∙kg−1
Water Requirement of Normal Consistency
/%
Setting Time
min
Le Chatelier Soundness Test
/mm
Mortar Strength
/MPa
Initial Setting Time/sFinal Setting Time/s3D Flexural Strength28D Flexural Strength3D Compressive Strength28D Compressive Strength
3.0934026.72292982.05.77.823.642.8
Table 2. Fly-ash performance index of Guizhou Huadian Tangzhai Power Generation Co., Ltd.
Table 2. Fly-ash performance index of Guizhou Huadian Tangzhai Power Generation Co., Ltd.
Fly-Ash GradeFineness/%Ignition Loss/%Water Content/%Water Demand Ratio/%
II23.55.20.284
Table 3. Basic material mix ratio of C30 SCFFC.
Table 3. Basic material mix ratio of C30 SCFFC.
Number of GroupsCement
/kg∙m−3
Machine-Made Sand
/kg∙m³
Crushed Stone
/kg∙m³
Fly-Ash
/kg∙m³
Water
/kg∙m³
Water Reducer
/%
Water-Binder RatioDensity
/kg∙m³
Defoamer
/‰
Air Entraining Agent/‰
Group 1372.94801.86867.2093.23204.311.000.4428000.10.05
Group 20.10
Group 30.15
Group 40.30.05
Group 50.10
Group 60.15
Group 70.50.05
Group 80.10
Group 90.15
Group 100.70.05
Group 110.10
Group 120.15
Table 4. The upper and lower critical values of SCFFC strength index.
Table 4. The upper and lower critical values of SCFFC strength index.
SCFFC Strength IndexLower Critical Values X1/MPaUpper Critical Values X2/MPa
Uniaxial compressive strength on the 7th day15.224.5
Uniaxial compressive strength on the 28th day25.833.7
Shear strength2.33.7
Table 5. Effects of different influencing factors on SCFFC strength.
Table 5. Effects of different influencing factors on SCFFC strength.
Influencing FactorsUniaxial Compressive Strength on the 7th Day/MPaUniaxial Compressive Strength on the 28th Day/MPaShear Strength/MPa
Defoamer/‰0.121.4a31.3a3.1a
0.317.6c28.3c2.7b
0.521.5a31.3a3.1a
0.719.1b29.9b2.9b
Air entraining agent/‰0.0522.2a32.0a3.3a
0.119.9b30.2b2.9b
0.1517.6c28.4c2.6c
Apparent hole density/Piece·mm−20–0.00121.0b30.8b3.0b
0.001–0.001519.4c30.3b3.0b
0.0015–0.00224.5a33.7a3.7a
0.002–0.002518.5d28.8c2.7a
Apparent defect density/‰0–1.521.9a31.7a3.2a
1.5–3.019.2b30.1b3.0b
3.0–4.517.9c28.7c2.6c
4.5–6.015.2d25.8d2.3d
Explanation: the lowercase letters marked in the table indicate that there is a significant difference at 0.05 level.
Table 6. Weight and average membership degree of factors affecting uniaxial compressive strength of SCFFC.
Table 6. Weight and average membership degree of factors affecting uniaxial compressive strength of SCFFC.
Influencing FactorsUniaxial Compressive Strength
7d28d7d28d7d28d7d28d7d28d
X ¯ σ / MPa σ /MPaCVσWσ Q ¯ σ
Defoamer19.930.21.641.240.080.040.080.040.551.56
Air entraining agent19.930.21.881.470.090.050.090.050.551.56
Apparent hole density20.930.92.291.780.110.060.110.060.531.53
Apparent defect density18.629.12.412.170.130.070.130.070.531.55
Table 7. Weight and average membership degree of factors affecting shear strength of SCFFC.
Table 7. Weight and average membership degree of factors affecting shear strength of SCFFC.
Influencing FactorsShear Strength
X ¯ τ / MPa τ/MPaCVτWτ Q ¯ τ
Defoamer3.00.170.060.090.52
Air entraining agent2.90.290.100.150.51
Apparent hole density3.10.370.120.180.49
Apparent defect density2.81.040.370.570.51
Table 8. SC and CSI of the influencing factors of SCFFC strength.
Table 8. SC and CSI of the influencing factors of SCFFC strength.
Influencing FactorsUniaxial Compressive StrengthShear Strength
7D28D7D28D
SCCSISCCSI
Defoamer0.750.860.040.060.760.05
Air entraining agent0.740.850.050.080.710.08
Apparent hole density0.760.860.060.090.740.09
Apparent defect density0.660.800.070.110.480.29
Table 9. Comparison of fuzzy evaluation value of influencing factors of uniaxial compression strength of SCFFC.
Table 9. Comparison of fuzzy evaluation value of influencing factors of uniaxial compression strength of SCFFC.
Influencing FactorsUniaxial Compression Strength
CVSCCSI
7D28D7D28D7D28D
ResultRankResultRankResultRankResultRankResultRankResultRank
Defoamer0.0840.0440.7520.8610.0440.064
Air entraining agent0.0930.0530.7430.8520.0530.083
Apparent hole density0.1120.0620.7610.8610.0620.092
Apparent defect density0.1310.0710.6640.8030.0710.111
Explanation: rank from big to small in the table.
Table 10. Comparison of fuzzy evaluation value of influencing factors of shear strength of SCFFC.
Table 10. Comparison of fuzzy evaluation value of influencing factors of shear strength of SCFFC.
Influencing FactorsShear Strength
CVSCCSI
ResultRankResultRankResultRank
Defoamer0.0640.7610.054
Air entraining agent0.1030.7130.083
Apparent hole density0.1220.7420.092
Apparent defect density0.3710.4840.291
Explanation: rank from big to small in the table.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Xie, C.; Tao, T.; Huang, K. Apparent Quality and Service Performance Evaluation of SCFFC in Tunnel Secondary Lining. Buildings 2022, 12, 479. https://doi.org/10.3390/buildings12040479

AMA Style

Xie C, Tao T, Huang K. Apparent Quality and Service Performance Evaluation of SCFFC in Tunnel Secondary Lining. Buildings. 2022; 12(4):479. https://doi.org/10.3390/buildings12040479

Chicago/Turabian Style

Xie, Caijin, Tiejun Tao, and Keyu Huang. 2022. "Apparent Quality and Service Performance Evaluation of SCFFC in Tunnel Secondary Lining" Buildings 12, no. 4: 479. https://doi.org/10.3390/buildings12040479

APA Style

Xie, C., Tao, T., & Huang, K. (2022). Apparent Quality and Service Performance Evaluation of SCFFC in Tunnel Secondary Lining. Buildings, 12(4), 479. https://doi.org/10.3390/buildings12040479

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.