Next Article in Journal
A Fast Calculation Method of Far-Field Intensity Distribution with Point Spread Function Convolution for High Energy Laser Propagation
Next Article in Special Issue
Micro Push-Out Bond Strength of Resin Composite to Dentin in Primary Dentition Using Three Universal Adhesives with Different pH: An In Vitro Study
Previous Article in Journal
Estrogen Signaling in Bone
Previous Article in Special Issue
Adhesion of Flowable Resin Composites in Simulated Wedge-Shaped Cervical Lesions: An In Vitro Pilot Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface

Department of Prosthodontics and Materials Science, University of Leipzig, 04109 Leipzig, Germany
*
Author to whom correspondence should be addressed.
Appl. Sci. 2021, 11(10), 4449; https://doi.org/10.3390/app11104449
Submission received: 26 March 2021 / Revised: 10 May 2021 / Accepted: 11 May 2021 / Published: 13 May 2021
(This article belongs to the Special Issue Developments and Applications of Dental Materials)

Abstract

:
In this prospective clinical trial we observed the 2-year clinical performance of posterior tooth-supported multi-unit fixed dental prostheses (FDP) fabricated from zirconia with monolithic occlusal surfaces. Fifty multi-unit FDPs were inserted in 50 patients. After two years of clinical service, 43 restorations were reexamined as one patient had died and six patients were not available for recall. Two biological (root canal treatment: 12 and 14 months) and one technical (debonding: 12 months) complications occurred. According to the Kaplan–Meier analysis, the success rate was 93.7%, and the survival rate was 100%. The six patients who were not available for regular 2-year follow-up were examined after the official 2-year recall interval, and none of the FDPs presented complications or failures. Within the limitations of the current study, the use of multi-unit FDPs with monolithic occlusal surfaces fabricated from zirconia can be recommended for short-term use in the posterior area.

1. Introduction

In comparison to silica-based ceramics, zirconia features the clinical benefits of higher flexural strength and less invasive preparation design. However, clinical complications are frequently reported, especially for chipping of the veneering ceramic [1]. Structural improvements of zirconia enhanced the translucency of the opaque material and enabled its use in a monolithic approach [2]. A few clinical studies observed the short-term longevity (up to three years) of tooth-supported multi-unit FDPs fabricated from 3 mol% yttria-stabilized zirconia, reporting survival rates from 93.8% to 100% [3,4]. For tooth- and implant-supported restorations, rates of 93.3% for survival and 81.8% for success were determined after the 2-year follow-up [5].
The aim of the present prospective study was to add data on the short-term performance of tooth-supported 3 mol% yttria-stabilized zirconia multiple-unit FDPs in the posterior area that are featured by monolithic occlusal surfaces.

2. Materials and Methods

Fifty patients were consecutively recruited at the Department of Prosthodontics and Materials Science, University of Leipzig, Germany who required treatment with a multi-unit FDP fabricated from zirconia in the posterior area (Table 1). Only FDPs with a terminal abutment design were included. Other inclusion criteria were vital or successfully endodontically treated abutment teeth with a biological width of at least 2 mm, healthy periodontal conditions, and sufficient oral hygiene. Exclusion criteria were patients aged 17 or younger, pregnancy, patients with multiple general diseases, and patients with xerostomia.
Further information is available in a previous publication [6]. The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethical Committee of the University of Leipzig (#298-14-25082018). All patients gave their written consent to take part in this investigation. The study was registered at the German Register of Clinical Studies (DRKS00019935). The preparation of abutment teeth was performed by either undergraduate students who were shadowed by an experienced dentist during the clinical courses in prosthodontics or by dentists of the department.
The preparation design was chosen according to guidelines for zirconia restorations [7] and dual-phase silicone impressions (Aquasil Ultra, Dentsply Sirona, Bensheim, Germany) were taken. All FDPs were fabricated in two dental laboratories and milled from 3 mol% yttria-stabilized zirconia. For some clinical scenarios, silica-based ceramics were used for facial veneering. After try-in procedures, the adjusted FDPs were properly polished and either conventionally or self-adhesively cemented (Table 1). The follow-up appointments comprised a baseline examination and reevaluations after 12 and 24 months.
The observed events were categorized as events with technical or biological origin. Moreover, failures were categorized as either the replacement of a restoration or extraction of an abutment tooth. Complications comprised restorations that required intervention but were still acceptable for intraoral service. Statistics were performed (SPSS 27, IBM, Armonk, NY, USA) by using Kaplan–Meier analysis to determine the survival (failure) and success (failure and complications) rates and 95% confidence intervals (CI).

3. Results

Between June 2014 and July 2018, a total of 50 patients were supplied with 50 zirconia multi-unit FDPs (28.0% facially veneered). Detailed information is presented in Table 1 and in a previous publication (6). At two-year follow-up (24.2 ± 2.2 months), 43 patients were examined; one patient had died, and six patients could not be recruited for recall.
Three complications occurred: two restorations required root canal treatment and one FDP debonded (Table 2, Figure 1). Regarding the restoration that debonded, chipping of the facial veneering occurred after 24 months, which was compensated by grinding and polishing. The success rate was 93.7% [95% CI 86.8; 100] and the survival rate was 100%. The six patients who were not available for the regular 2-year follow-up could be examined after the official 2-year recall interval, and none of the FDPs presented a complication or failure.

4. Discussion

The survival (100%) and success (93.7%) rates determined in the present study were similar to previous investigations examining multi-unit FDPs [3,4]. For single crowns, slightly lower survival rates (92.8–98.5%) were reported after three years of intraoral use [8,9]. In general, differences of survival rates for monolithic zirconia restorations might be explained by variations in the manufacturing process—particularly during occlusal adjustments [9]. Regarding complications, the extensive wear of zirconia or antagonists against zirconia has been described and discussed but might be neglectable when premising a properly polished zirconia surface [10,11].
Therefore, these considerations emphasize that monolithic occlusal surfaces fabricated from zirconia could be an interesting option for patients with bruxism. In these clinical scenarios, short-term clinical use was positively evaluated in several clinical trials [5,12,13]. In the present study, bruxism was not assessed according to the current international guidelines but was not explicitly excluded [14]. Another shortcoming of this study is the limited sample size, which was due to the long-lasting recruiting process of patients. Nevertheless, the results of this study suggest that the short-term clinical use of multi-unit FDPs fabricated from monolithic zirconia in the posterior region can be recommended.

Author Contributions

E.P. data curation, investigation, formal analysis, software, visualization, and writing original draft; S.H. project administration, resources, supervision, validation, and writing review & editing; O.S. conceptualization, methodology, supervision, and writing review & editing; M.B.S. investigation, validation, and writing review & editing; A.S. investigation, validation, and writing review & editing; A.R. conceptualization, formal analysis, methodology, software, visualization, and writing review & editing. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Institutional Review Board of University of Leipzig (#298-14-25082018).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Data can be requested from the authors upon reasonable request.

Acknowledgments

The authors acknowledge support from Leipzig University for Open Access Publishing.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Limones, A.; Molinero-Mourelle, P.; Azevedo, L.; Romeo-Rubio, M.; Correia, A.; Gómez-Polo, M. Zirconia-ceramic versus metal-ceramic posterior multiunit tooth-supported fixed dental prostheses: A systematic review and meta-analysis of randomized controlled trials. J. Am. Dent. Assoc. 2020, 151, 230–238. [Google Scholar] [CrossRef] [PubMed]
  2. Stawarczyk, B.; Keul, C.; Eichberger, M.; Figge, D.; Edelhoff, D.; Lümkemann, N. Three generations of zirconia: From veneered to monolithic. Part I. Quintessence Int. 2017, 48, 369–380. [Google Scholar] [PubMed]
  3. Pontevedra, P.; Lopez-Suarez, C.; Pelaez, J.; Garcia-Serdio, S.; Suarez, M.J. Prospective Clinical Evaluation of Posterior Monolithic Zirconia Fixed Partial Dentures Using a Complete Digital Workflow: Two-Year Follow-Up. J. Prosthodont. 2021, 30, 298–304. [Google Scholar] [CrossRef] [PubMed]
  4. Habibi, Y.; Dawid, M.T.; Waldecker, M.; Rammelsberg, P.; Bömicke, W. Three-year clinical performance of monolithic and partially veneered zirconia ceramic fixed partial dentures. J. Esthet. Restor. Dent. 2020, 32, 395–402. [Google Scholar] [CrossRef] [PubMed]
  5. Koenig, V.; Wulfman, C.; Bekaert, S.; Dupont, N.; le Goff, S.; Eldafrawy, M.; Vanheusden, A.; Mainjot, A. Clinical behavior of second-generation zirconia monolithic posterior restorations: Two-year results of a prospective study with Ex vivo analyses including patients with clinical signs of bruxism. J. Dent. 2019, 91, 103229. [Google Scholar] [CrossRef] [PubMed]
  6. Rauch, A.; Pahncke, E.J.; Hahnel, S.F.; Schierz, O. Do monolithic zirconia restorations affect TMD signs and symptoms? Data from a prospective clinical trial after one year of observation. Int. J. Prosthodont. 2021. [Google Scholar] [CrossRef] [PubMed]
  7. Kern, M.; Thompson, V.P.; Beuer, F.; Frankenberger, R.; Kohal, R.J.; Kunzelmann, P.; Pospiech, P.; Reiss, B. All-Ceramics at A Glance, 3rd ed.; AG Keramik: Malsch, Germany, 2017. [Google Scholar]
  8. Bömicke, W.; Rammelsberg, P.; Stober, T.; Schmitter, M. Short-term prospective clinical evaluation of monolithic and partially veneered zirconia single crowns. J. Esthet. Restor. Dent. 2017, 29, 22–30. [Google Scholar] [CrossRef] [PubMed]
  9. Miura, S.; Yamauchi, S.; Kasahara, S.; Katsuda, Y.; Fujisawa, M.; Egusa, H. Clinical evaluation of monolithic zirconia crowns: A failure analysis of clinically obtained cases from a 3.5-year study. J. Prosthodont. Res. 2020. [Google Scholar] [CrossRef]
  10. Esquivel-Upshaw, J.F.; Kim, M.J.; Hsu, S.M.; Abdulhameed, N.; Jenkins, R.; Neal, D.; Ren, F.; Clark, A.E. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns. J. Dent. 2018, 68, 19–27. [Google Scholar] [CrossRef] [Green Version]
  11. Preis, V.; Grumser, K.; Schneider-Feyrer, S.; Behr, M.; Rosentritt, M. Cycle-dependent in vitro wear performance of dental ceramics after clinical surface treatments. J. Mech. Behav. Biomed. Mater. 2016, 53, 49–58. [Google Scholar] [CrossRef] [PubMed]
  12. Levartovsky, S.; Pilo, R.; Shadur, A.; Matalon, S.; Winocur, E. Complete rehabilitation of patients with bruxism by veneered and non-veneered zirconia restorations with an increased vertical dimension of occlusion: An observational case-series study. J. Prosthodont. Res. 2019, 63, 440–446. [Google Scholar] [CrossRef]
  13. Hansen, T.L.; Schriwer, C.; Øilo, M.; Gjengedal, H. Monolithic zirconia crowns in the aesthetic zone in heavy grinders with severe tooth wear—An observational case-series. J. Dent. 2018, 72, 14–20. [Google Scholar] [CrossRef]
  14. Lobbezoo, F.; Ahlberg, J.; Raphael, K.G.; Wetselaar, P.; Glaros, A.G.; Kato, T.; Santiago, V.; Winocur, E.; de Laat, A.; de Leeuw, R.; et al. International consensus on the assessment of bruxism: Report of a work in progress. J. Oral. Rehabil. 2018, 45, 837–844. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Kaplan–Meier curves for the survival and success of multi-unit fixed partial dentures with monolithic occlusal surfaces fabricated from zirconia (insertion n = 50; 2-year follow-up n = 43).
Figure 1. Kaplan–Meier curves for the survival and success of multi-unit fixed partial dentures with monolithic occlusal surfaces fabricated from zirconia (insertion n = 50; 2-year follow-up n = 43).
Applsci 11 04449 g001
Table 1. Characteristics of the patient population and restorations.
Table 1. Characteristics of the patient population and restorations.
ParameterOutcome
Age (years)mean 56.9 ± 13.1; min. 29; max. 80
Gender52.0% female48.0% male
Units74.0% (3 units)16.0% (4 units)8.0% (5 units)2.0% (6 units)
Veneering28.0% facial72.0% no veneering
Material (manufacturer)62.0% Zenostar ZR translucent (Wieland, Pforzheim, Germany)20.0% Lava Plus (3M, Saint Paul, MN, USA)10.0% DD Bio ZX2 (Dental Direkt, Spenge, Germany)8.0% NexxZr T (Sagemax, Lindau, Germany)
Cementation14.0% zinc oxide phosphate52.0% glass ionomer cement34.0% RelyX Unicem (3M, Saint Paul, MN, USA)
Table 2. Overview of the events.
Table 2. Overview of the events.
EventUnits/Facial VeneeringMaterialCementationType of EventTime of Event (Months)
I complication3/yesZenostar ZR translucent
(Wieland, Pforzheim, Germany)
glass ionomer
cement
technical, debonding12
II complication4/noZenostar ZR translucent
(Wieland, Pforzheim, Germany)
glass ionomer
cement
biological, symptomatic irreversible pulpitis 12
III complication4/yesLava Plus (3M, Saint Paul, MN, USA)glass ionomer
cement
biological, asymptomatic apical periodontitis14
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Pahncke, E.; Hahnel, S.; Schierz, O.; Schmidt, M.B.; Schmutzler, A.; Rauch, A. Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface. Appl. Sci. 2021, 11, 4449. https://doi.org/10.3390/app11104449

AMA Style

Pahncke E, Hahnel S, Schierz O, Schmidt MB, Schmutzler A, Rauch A. Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface. Applied Sciences. 2021; 11(10):4449. https://doi.org/10.3390/app11104449

Chicago/Turabian Style

Pahncke, Elisabeth, Sebastian Hahnel, Oliver Schierz, Michael Benno Schmidt, Anne Schmutzler, and Angelika Rauch. 2021. "Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface" Applied Sciences 11, no. 10: 4449. https://doi.org/10.3390/app11104449

APA Style

Pahncke, E., Hahnel, S., Schierz, O., Schmidt, M. B., Schmutzler, A., & Rauch, A. (2021). Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface. Applied Sciences, 11(10), 4449. https://doi.org/10.3390/app11104449

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop