RETRACTED: Accuracy Assessment of Implant Placement in a Newly Developed Dynamic Navigation System: A Pilot Study
Abstract
:1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Dynamic Navigation System
2.3. Preoperative Procedure
2.4. Implant Placement Using Dynamic Navigation
2.5. Statistical Evaluation of Implant Position Accuracy
3. Results
3.1. Subject Profiles and Implant Distribution
3.2. Mean and Median Values of Each Deviation and Comparison with Previous Reviews
3.3. Comparative Analysis between Flapless Surgery and Open-Flap Surgery
3.4. Comparative Analysis between Surgeons
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Block, M.S.; Emery, R.W. Static or Dynamic Navigation for Implant Placement-Choosing the Method of Guidance. J. Oral Maxillofac. Surg. 2016, 74, 269–277. [Google Scholar] [CrossRef]
- Block, M.S.; Emery, R.W.; Lank, K.; Ryan, J. Implant Placement Accuracy Using Dynamic Navigation. Int. J. Oral Maxillofac. Implants 2017, 32, 92–99. [Google Scholar] [CrossRef]
- Chen, C.K.; Yuh, D.Y.; Huang, R.Y.; Fu, E.; Tsai, C.F.; Chiang, C.Y. Accuracy of Implant Placement with a Navigation System, a Laboratory Guide, and Freehand Drilling. Int. J. Oral Maxillofac. Implants 2018, 33, 1213–1218. [Google Scholar] [CrossRef]
- Gargallo-Albiol, J.; Barootchi, S.; Salomó-Coll, O.; Wang, H.L. Advantages and disadvantages of implant navigation surgery. A systematic review. Ann. Anat. 2019, 225, 1–10. [Google Scholar] [CrossRef] [PubMed]
- Panchal, N.; Mahmood, L.; Retana, A.; Emery, R., 3rd. Dynamic Navigation for Dental Implant Surgery. Oral Maxillofac. Surg. Clin. N. Am. 2019, 31, 539–547. [Google Scholar] [CrossRef]
- Kaewsiri, D.; Panmekiate, S.; Subbalekha, K.; Mattheos, N.; Pimkhaokham, A. The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial. Clin. Oral Implants Res. 2019, 30, 505–514. [Google Scholar] [CrossRef]
- Emery, R.W.; Merritt, S.A.; Lank, K.; Gibbs, J.D. Accuracy of Dynamic Navigation for Dental Implant Placement-Model-Based Evaluation. J. Oral Implantol. 2016, 42, 399–405. [Google Scholar] [CrossRef]
- Mediavilla Guzmán, A.; Riad Deglow, E.; Zubizarreta-Macho, Á.; Agustín-Panadero, R.; Hernández Montero, S. Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study. J. Clin. Med. 2019, 8, 2123. [Google Scholar] [CrossRef]
- Stefanelli, L.V.; DeGroot, B.S.; Lipton, D.I.; Mandelaris, G.A. Accuracy of a Dynamic Dental Implant Navigation System in a Private Practice. Int. J. Oral Maxillofac. Implants 2019, 34, 205–213. [Google Scholar] [CrossRef] [PubMed]
- Sun, T.M.; Lee, H.E.; Lan, T.H. Comparing Accuracy of Implant Installation with a Navigation System (NS), a Laboratory Guide (LG), NS with LG, and Freehand Drilling. Int. J. Environ. Res. Public Health 2020, 17, 2107. [Google Scholar] [CrossRef]
- Aydemir, C.A.; Arısan, V. Accuracy of dental implant placement via dynamic navigation or the freehand method: A split-mouth randomized controlled clinical trial. Clin. Oral Implants Res. 2020, 31, 255–263. [Google Scholar] [CrossRef]
- Wu, D.; Zhou, L.; Yang, J.; Zhang, B.; Lin, Y.; Chen, J.; Huang, W.; Chen, Y. Accuracy of dynamic navigation compared to static surgical guide for dental implant placement. Int. J. Implant Dent. 2020, 6, 78. [Google Scholar] [CrossRef] [PubMed]
- Edelmann, C.; Wetzel, M.; Knipper, A.; Luthardt, R.G.; Schnutenhaus, S. Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial. J. Clin. Med. 2021, 10, 1808. [Google Scholar] [CrossRef]
- Gargallo-Albiol, J.; Barootchi, S.; Marqués-Guasch, J.; Wang, H.L. Fully Guided Versus Half-Guided and Freehand Implant Placement: Systematic Review and Meta-analysis. Int. J. Oral Maxillofac. Implants 2020, 35, 1159–1169. [Google Scholar] [CrossRef] [PubMed]
- Al Yafi, F.; Camenisch, B.; Al-Sabbagh, M. Is Digital Guided Implant Surgery Accurate and Reliable? Dent. Clin. N. Am. 2019, 63, 381–397. [Google Scholar] [CrossRef]
- Cristache, C.M.; Burlibasa, M.; Tudor, I.; Totu, E.E.; Di Francesco, F.; Moraru, L. Accuracy, Labor-Time and Patient-Reported Outcomes with Partially versus Fully Digital Workflow for Flapless Guided Dental Implants Insertion-A Randomized Clinical Trial with One-Year Follow-Up. J. Clin. Med. 2021, 10, 1102. [Google Scholar] [CrossRef]
- El Kholy, K.; Janner, S.F.M.; Schimmel, M.; Buser, D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin. Implant Dent. Relat. Res. 2019, 21, 101–107. [Google Scholar] [CrossRef]
- Li, J.; Chen, Z.; Chan, H.L.; Sinjab, K.; Yu, H.; Wang, H.L. Does flap opening or not influence the accuracy of semi-guided implant placement in partially edentulous sites? Clin. Implant Dent. Relat. Res. 2019, 21, 1253–1261. [Google Scholar] [CrossRef] [PubMed]
- Putra, R.H.; Yoda, N.; Iikubo, M.; Kataoka, Y.; Yamauchi, K.; Koyama, S.; Cooray, U.; Astuti, E.R.; Takahashi, T.; Sasaki, K. Influence of bone condition on implant placement accuracy with computer-guided surgery. Int. J. Implant Dent. 2020, 6, 62. [Google Scholar] [CrossRef]
- El Kholy, K.; Lazarin, R.; Janner, S.F.M.; Faerber, K.; Buser, R.; Buser, D. Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery. Clin. Oral Implants Res. 2019, 30, 1067–1075. [Google Scholar] [CrossRef]
- Sun, T.M.; Lee, H.E.; Lan, T.H. The influence of dental experience on a dental implant navigation system. BMC Oral Health 2019, 19, 222. [Google Scholar] [CrossRef]
- Kaku, T.; Ogino, Y.; Matsushita, Y.; Koyano, K. Technique for identifying keratinized gingival tissue and soft tissue morphology on 3-dimensional implant-planning software images. J. Prosthet. Dent. 2016, 116, 21–24. [Google Scholar] [CrossRef]
- Lin, G.H.; Chan, H.L.; Wang, H.L. The significance of keratinized mucosa on implant health: A systematic review. J. Periodontol. 2013, 84, 1755–1767. [Google Scholar] [CrossRef]
- Bover-Ramos, F.; Viña-Almunia, J.; Cervera-Ballester, J.; Peñarrocha-Diago, M.; García-Mira, B. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies. Int. J. Oral Maxillofac. Implants 2018, 33, 101–115. [Google Scholar] [CrossRef] [PubMed]
- Wei, S.M.; Zhu, Y.; Wei, J.X.; Zhang, C.N.; Shi, J.Y.; Lai, H.C. Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis. Clin. Oral Implants Res. 2021, 32, 383–393. [Google Scholar] [CrossRef]
- Schnutenhaus, S.; Edelmann, C.; Knipper, A.; Luthardt, R.G. Accuracy of Dynamic Computer-Assisted Implant Placement: A Systematic Review and Meta-Analysis of Clinical and In Vitro Studies. J. Clin. Med. 2021, 10, 704. [Google Scholar] [CrossRef]
- Jorba-García, A.; González-Barnadas, A.; Camps-Font, O.; Figueiredo, R.; Valmaseda-Castellón, E. Accuracy assessment of dynamic computer-aided implant placement: A systematic review and meta-analysis. Clin. Oral Investig. 2021, 25, 2479–2494. [Google Scholar] [CrossRef]
- Hong, J.; Matsumoto, N.; Ouchida, R.; Komune, S.; Hashizume, M. Medical navigation system for otologic surgery based on hybrid registration and virtual intraoperative computed tomography. IEEE Trans. Biomed. Eng. 2009, 56, 426–432. [Google Scholar] [CrossRef]
- Matsumoto, N.; Oka, M.; Cho, B.; Hong, J.; Jinnouchi, M.; Ouchida, R.; Hashizume, M.; Komune, S. Cochlear implantation assisted by noninvasive image guidance. Otol. Neurotol. 2012, 33, 1333–1338. [Google Scholar] [CrossRef] [PubMed]
- Oka, M.; Cho, B.; Matsumoto, N.; Hong, J.; Jinnouchi, M.; Ouchida, R.; Komune, S.; Hashizume, M. A preregistered STAMP method for image-guided temporal bone surgery. Int. J. Comput. Assist. Radiol. Surg. 2014, 9, 119–126. [Google Scholar] [CrossRef]
- Block, M.S.; Emery, R.W.; Cullum, D.R.; Sheikh, A. Implant Placement Is More Accurate Using Dynamic Navigation. J. Oral Maxillofac. Surg. 2017, 75, 1377–1386. [Google Scholar] [CrossRef] [PubMed]
- Golob Deeb, J.; Bencharit, S.; Carrico, C.K.; Lukic, M.; Hawkins, D.; Rener-Sitar, K.; Deeb, G.R. Exploring training dental implant placement using computer-guided implant navigation system for predoctoral students: A pilot study. Eur. J. Dent. Educ. 2019, 23, 415–423. [Google Scholar] [CrossRef] [PubMed]
- Pellegrino, G.; Bellini, P.; Cavallini, P.F.; Ferri, A.; Zacchino, A.; Taraschi, V.; Marchetti, C.; Consolo, U. Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study. Int. J. Environ. Res. Public Health 2020, 17, 2153. [Google Scholar] [CrossRef] [PubMed]
Maxilla | Mandible | |
---|---|---|
Incisors and Canines | 8 (0) * | 2 (1) * |
Premolars and Molars | 30 (6) * | 26 (13) * |
Angular Deviations (°) | Apical Deviation (mm) | Coronal Deviation (mm) | Vertical Deviation (mm) | |
---|---|---|---|---|
Bover-Ramos et al. [24] (mean ± SD) | 3.98 ± 0.33 | 1.40 ± 0.12 | 1.10 ± 0.99 | 0.74 ± 0.10 |
Wei et al. [25] (mean, 95% CI) | 4.22 (2.74, 5.68) | 1.45 (1.19, 1.72) | 1.11 (0.96, 1.26) | Not analyzed |
Schnutenhaus et al. [26] (mean, 95% CI) | 4.10 (3.12, 5.10) | 1.33(0.98, 1.68). | 1.00 (0.83, 1.16) | Not analyzed |
Jorba-García et al. [27] (mean, 95% CI) | 3.68 (3.61, 3.74) | 0.90 (0.83, 0.97) | 0.69 (0.67, 0.72) | 0.73 (0.70, 0.76) |
Present study (mean, 95% CI) | 2.93 (2.75, 3.10) | 1.15 (1.01, 1.29) | 0.96 (0.84, 1.08) | 0.71 (0.66, 0.77) |
Present study (median, IQR) | 3.07 (2.52–3.54) | 0.96 (0.75–1.42) | 0.76 (0.57–1.37) | 0.71 (0.61–0.88) |
Angular Deviations (°) | Apical Deviation (mm) | Coronal Deviation (mm) | Vertical Deviation (mm) | |
---|---|---|---|---|
Flapless surgery | 2.92 (2.37–3.41) | 0.93 (0.72–1.11) | 0.68 (0.56–1.21) | 0.72 (0.61–0.88) |
Open-flap surgery | 3.34 (2.64–3.65) | 1.37 (0.90–1.88) | 1.27 (0.72–1.67) | 0.67 (0.51–0.90) |
p value | 0.06 | <0.01 | <0.05 | 0.70 |
Effect size (r) | 0.23 | 0.36 | 0.30 | −0.04 |
Angular Deviations (°) | Apical Deviation (mm) | Coronal Deviation (mm) | Vertical Deviation (mm) | |
---|---|---|---|---|
Well-experienced | 2.76 (2.38–3.22) | 0.93 (0.71–1.12) | 0.61 (0.51–0.88) | 0.71 (0.61–0.88) |
Less-experienced | 3.29 (2.35–3.62) | 0.92 (0.76–1.05) | 1.15 (0.62–1.63) | 0.71 (0.63–0.89) |
p value | 0.11 | 0.96 | <0.01 | 0.95 |
Effect size (r) | 0.19 | −0.004 | 0.33 | 0.007 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Setoguchi, T.; Ogino, Y.; Ouchida, R.; Takahashi, A.; Ayukawa, Y.; Koyano, K. RETRACTED: Accuracy Assessment of Implant Placement in a Newly Developed Dynamic Navigation System: A Pilot Study. Appl. Sci. 2021, 11, 6593. https://doi.org/10.3390/app11146593
Setoguchi T, Ogino Y, Ouchida R, Takahashi A, Ayukawa Y, Koyano K. RETRACTED: Accuracy Assessment of Implant Placement in a Newly Developed Dynamic Navigation System: A Pilot Study. Applied Sciences. 2021; 11(14):6593. https://doi.org/10.3390/app11146593
Chicago/Turabian StyleSetoguchi, Tomoyuki, Yoichiro Ogino, Riichi Ouchida, Akira Takahashi, Yasunori Ayukawa, and Kiyoshi Koyano. 2021. "RETRACTED: Accuracy Assessment of Implant Placement in a Newly Developed Dynamic Navigation System: A Pilot Study" Applied Sciences 11, no. 14: 6593. https://doi.org/10.3390/app11146593
APA StyleSetoguchi, T., Ogino, Y., Ouchida, R., Takahashi, A., Ayukawa, Y., & Koyano, K. (2021). RETRACTED: Accuracy Assessment of Implant Placement in a Newly Developed Dynamic Navigation System: A Pilot Study. Applied Sciences, 11(14), 6593. https://doi.org/10.3390/app11146593