1. Introduction
The drinking temperature significantly influences the perception of wine, as it affects the sensory attributes such as smell, taste, and mouthfeel [
1]. Each wine type is usually most appreciated at an individual temperature according to its sensory characteristics. White wines are consumed relatively cool, whereas red wines are usually enjoyed slightly warmer but still below common room temperature [
2]. In general, wine should be tempered appropriately before serving and drinking to provide the best taste experience. However, wine is often not drunk immediately after pouring and warms up in the glass due to thermal interaction with warmer surroundings. This should be considered when preparing wine. It is usually unknown how quickly the wine warms up in a glass. To the authors’ knowledge, the warming of wine has not been the subject of a scientific investigation to date.
Literature on wine in the context of heat transfer and corresponding numerical simulation is scarce. Beamont et al. [
3] investigated the bubble-driven flow of champagne in a glass with computational fluid dynamics (CFD). The group also conducted simulations with different, but fixed champagne temperatures for the same flow [
4]. Other studies investigate the flow and thermodynamical processes in wine fermentation tanks with CFD methods [
5,
6,
7]. Simulations were also used to examine the cooling and ventilation system of wine refrigerators [
8,
9] and wine cellars [
10]. The rheological and thermodynamical properties of wine were investigated in some studies, e.g., [
11,
12,
13].
Several studies showed the influence of the drinking temperature on the sensory attributes of wine. Cool temperatures decrease the human perception of sweetness and increase the perception of sourness [
14]. Bitterness and astringency get more pronounced with decreasing wine temperature [
14,
15]. Higher wine temperatures increase volatility, allowing more compounds to dissolve from the wine in the glass and enhance the wine’s aroma [
1,
15,
16]. The panelists in a study by Ross et al. [
16] perceived red wines at
rather as bitter and astringent and less sweet compared to the same wines tasted at
. The red wines were more often described with aromatic attributes at
than at
. According to [
2,
17], wine can smell and taste too alcoholic when it is too warm due to the accelerated evaporation of ethanol.
Although the drinking temperature preference may be individual, there are general guidelines for the serving temperature of the different wine types. The Oxford companion on wine by Robinson and Harding [
2] specifies that full or tannic red wines should be served at
. In contrast, medium-bodied and light red wines are usually offered a few degrees colder. Full and complex dry white wines should be served at
. Dry (aromatic) white wines with a medium or light body are liked most at around
serving temperature. Sweet, light white wines should be offered even cooler at around
. It is recommended that the wine should usually be served at the lower end of the indicated ranges since it warms up relatively fast in the glass [
2]. To the best of the authors’ knowledge, no profound information is available on how fast wine warms up in a glass.
This study aims to close this gap and examines the physical process of wine warming in a glass and determines the wine’s temperature change over time. The warming process is modeled and computed using numerical simulation. The simulation can reveal the governing heating phenomena and can be easily applied to different configurations for similar heating problems. A conjugate heat transfer simulation models the crucial heating mechanisms such as thermal conduction, convection, and radiation. The simulation approach considers only non-sparkling wines. Buoyancy effects due to rising bubbles are not included. Sweet dessert wines or fortified wines with high sugar content are not examined either. The study focuses on one configuration with one specific glass and filling quantity to closely investigate the physical process and the applied computational methods. Experiments are presented providing reference data to evaluate and validate the simulation approach. The importance of modeling the different heating mechanisms is examined in detail.
The temperature increase of wine is determined for various combinations of the initial wine temperature after pouring and ambient temperature. The results can inform sommeliers, restaurateurs, and wine enthusiasts about how wines should be tempered to reach the optimal drinking temperature under different room and storage conditions. For example, one could determine how long a red wine has to remain in a glass to reach a certain temperature when the bottle was stored cool at a known temperature. Red wine could also be stored at a specific low temperature to let it breathe in a glass for a given period while reaching the ideal drinking temperature. To optimize the drinking experience, especially on hot summer days, bars or restaurants could adjust the storage temperature of white wines based on ambient temperature and the time it takes to serve them. Besides practical advice, this study also gives insights into the physical effects of wine warming as the local and temporal influence of different heating mechanisms are investigated. The presented simulation approach could be utilized to develop new wine glasses with regard to their thermal behavior. Thus, producers could optimize the glass shape to potentially reduce wine warming.
The investigated configuration of wine warming in a glass is specified in
Section 2. Experiments were conducted for the same configuration. The experimental setup, procedure, and results are presented in
Section 2.1 and the following sections.
Section 3 outlines the conjugate heat transfer simulation approach, including the governing equations, the material modeling and properties and the simulation setup. The simulation approach is validated with the experimental data in
Section 4. Furthermore, the influence of different heating mechanisms and fluid properties is investigated.
Section 5 presents the main results and findings. The warming process is analyzed, and a parameter study for different initial and surrounding temperatures is performed.
Section 6 summarizes the results and gives an outlook on potential further research questions.
2. Problem Configuration and Experiments
The study investigated the warming of 150 mL of non-sparkling wine in a medium-sized red wine glass.
Figure 1b shows the glass dimensions of the CAD (computer-aided design) model that was derived from available drawings and measurements. The glass has a maximum outer diameter of 90 mm and a height of 225 mm. Its total capacity is 490 mL. With the coordinate system originating in the bottom of the glass’s center, the wine surface is located at
mm. The glass’s dimensions are similar to universal wine glasses used for white and red wine. The glass is only slightly larger than many white wine glasses. Therefore, it could also be used to consume white wine. The authors purchased the glass from the producer Stölzle Lausitz GmbH (Weißwasser/Oberlausitz, Germany).
The filled glass was positioned on a wooden table in an empty room. Table, air, and room walls were initially at the same temperature, referred to as the room temperature . The initial wine temperature was less than . The configuration did not experience external influences like hands touching the glass or swirling. The effect of the pouring process was neglected. Thus, the wine warmed up only through heat exchange with the warmer surroundings.
2.1. Experimental Setup and Procedure
The experimental study investigated the warming of red wine, white wine, and tap water at . Two experiments were performed according to the configuration described above to obtain comprehensive reference data for validation. In the first experiment, the average temperature of wine and water was measured after predefined periods. The second one determined the temperature increase over time of water at specified locations inside the glass. The experiments included tap water to simplify the comparability to the simulation for detailed validation and to investigate the liquid composition’s influence.
Figure 1a shows the experimental setup. A Greisinger resistance thermometer with a platinum sensor (Pt1000, accuracy
for
) was used as in similar experiments related to food [
18,
19] and wine [
20]. A mounting device fixed the thermometer sensor in a vertical direction above the glass. The sensor tip was positioned inside the liquid (wine or water) and could be moved in a vertical direction. The diameter of the cylindrical sensor was
mm. The mass of the sensor was relatively small compared to the mass of the wines, which allowed the assumption of negligible heat transfer from the thermometer to the liquid. The mounting device was designed to influence the physical processes as little as possible. The glass was placed in the middle of a spruce wooden board, with the dimensions
mm. The examined red wine was from Primitivo grapes containing
of volume alcohol, 10.7 g
(grams per liter) residual sugar, and 6.8 g
acidity. The white wine was a Cuvee with 11.5% of volume alcohol, 11.8 g
residual sugar, and 6.5 g
acidity, as communicated by the producers.
Before starting the experiments, the wine and tap water were kept cool in a refrigerator at . 150 mL of the corresponding liquid were poured into a calibrated measuring cylinder, with an accuracy of ±2 mL. The liquid was slowly heated until it nearly reached the required initial temperature to account for the temperature increase during the pouring. The small temperature change was caused by interaction with the air and was about for . The liquid was poured into the glass, where the thermometer sensor was placed to verify the correct initial temperature immediately after finishing the pouring process. The timing started as soon as the liquid had been poured into the glass.
2.2. Average Wine and Water Temperatures
For the first experiment, the thermometer sensor was removed from the glass immediately after pouring and measuring the initial liquid temperature. The experimental setup was not disturbed for 5, 10, 20, or 40 min, respectively. Afterwards, the liquid was mixed quickly in the glass with a plastic stirring device to achieve a uniform temperature distribution without introducing additional heat. The temperature was measured in the middle of the liquid. The result was taken as the average temperature of the water or wine in the glass.
This experiment was performed with red wine and water for the initial temperatures of
and
. The white wine was measured for
. The experiment was conducted five times for each period and liquid.
Figure 2a,b present the mean temperature and the standard deviation of the measurements. After each period, the mean temperature is nearly the same for water, red, and white wine. The maximal difference is only about
between the mean temperature of the water and red wine for
after 40 min. The results indicate that, apart from water, the additional components in wine do not significantly affect the warming process in the glass. The impact of the alcohol content seems to be negligible, considering the difference of
alcohol between red wine and water. Furthermore, there is no notable difference between the red wine and white wine with
alcohol in terms of warming at similar sugar and acidity levels. The investigated wines contain a moderate sugar content, typical of semi-dry wines [
2]. Sugar is the only component that can vastly vary between dry and sweet wines, in quantity, relevant to the warming [
21]. Therefore, the warming process could differ for wines with a significantly higher sugar content, which is not explored here. The standard deviations are relatively small. Hence, only the mean temperatures are included in the figures throughout this work.
2.3. Temperature Increase of Water over Time
The second experiment determined the temperature of water with
over time at three positions along the glass symmetry axis. The temperature was measured in the center of the glass (
mm) at 10, 20 and
mm below the water surface. The corresponding positions are denoted
,
, and
, i.e.,
mm. It should be noted that the thermometer sensor tip was located
mm below the specified positions since the temperature is measured over a small distance and not directly at the end. The sensor stayed in the water for 45 min while the experimental setup was not disturbed. The temperature was measured and recorded every five seconds. The measurement over the entire period was conducted five times for each position. The mean of the five measurements in each time stamp and the corresponding standard deviation are shown in
Figure 3. The standard deviation decreases with the increasing distance from the water surface, but it is still reasonably small at
. The layered results from
to
suggest a stratification of temperatures within the wine. The numerical investigations will reveal why natural convection effects cannot diminish the stratification.
4. Validation
The presented simulation approach was validated for warming wine and water at a room temperature of
. The simulation results for the initial temperature of
and
were compared to the experimental data from
Section 2.2 and
Section 2.3. Detailed validation was first performed for water rather than wine to reduce the possibility of modeling errors for the liquid. The following investigates the importance of modeling different physical heating mechanisms closely. Then, the simulation of wine was evaluated, and the effects of the liquid properties are discussed.
Figure 6 presents the results for warming water. The simulated temperature increase, see
Figure 6a, and fits the experimental data accurately in all three positions. The temperature is computed slightly too low only for
. The initial rapid temperature increase starts with a delay of about 40 s. Minor differences in the initial conditions between the experiment and simulation are probably the reason for this. The pouring process in the experiment presumably introduces a small initial motion in the water so that the heat is transported faster from the glass wall to the middle of the liquid. The simulation takes a few seconds to establish the natural convection since starting from a zero velocity field. Nevertheless, the agreement is surprisingly accurate, considering the comparison in single discrete positions of the underlying complex physical system.
Figure 6b compares the average water temperatures. The simulation matches the experimental data for all investigated periods well. The simulated temperature is slightly overpredicted for
. However, the difference is only
after 5 min and
after 40 min. This corresponds to a relative error of 5.5% and 1.8% in relation to the corresponding temperature change, respectively. It should be noted that the discrepancy is within the range of the thermometer’s measurement accuracy. The comparison for
shows slightly larger errors for
and
. This could be due to the relatively small number of measurements, and the experiment’s higher error sensitivity at lower temperatures. At
, the maximum difference is still relatively small with 4.4% or
, while the prediction for
and
is accurate. Overall, the simulation agrees very well with the experimental data and accurately represents the physical process of water warming in a glass.
The importance of including the physical effects of convection and radiation in the simulation is investigated hereafter. The influence of modeling both mechanisms on the total heat transfer is examined for the warming of water with
. The convection of the air and the liquid in the glass are involved in the physical process. The simulation approach can disregard the convection of the liquid and the air by not calculating the corresponding velocity field. A simulation without radiation neglects Equation (
9). All simulation variations still model heat conduction. The comprehensive baseline simulation, including all physical phenomena, is compared to the simulation without taking into account (1) the convection of the air, (2) the convection of the water, (3) the radiation, and (4) the radiation and convection of the air.
Figure 7 shows the resulting average water temperatures compared to the experimental data. The baseline simulation computes the temperature only
higher than the experiment at
. Leaving out one of the mechanisms reduces the temperature increase over time. The convection of water affects the warming the least, whereas the convection of the air has a more significant influence. Without considering the water convection, the temperature increase after 40 min is
lower compared to the experiment. This corresponds to a relative error of 6.0% in relation to the absolute temperature change. For the air convection, the error is 19.7% or
. Surprisingly, radiation has a relatively large influence and affects warming more than convection. Not including radiation in the simulation results in a
lower temperature, corresponding to a relative error of 33.6%. This is unexpected, since most practitioners probably consider the influence of radiation negligible at relatively low present temperatures. However, the result is well in agreement with the standard literature, compared to example 16.5-2 in [
37], which features comparable absolute temperatures, temperature differences, and emissivities. Without simulating radiation and convection of the room air, the predicted temperature is off by 66.3% or
. These results show that the numerical simulation has to account for the convection and, especially, the radiation to appropriately model the heat transfer for liquid warming in a glass. A simple heat transfer model considering only the heat conduction would not be sufficient to depict the complex physical process. The local and temporal effects of the physical heating mechanisms are discussed more closely in
Section 5.
Now, the simulation for red wine warming in the glass was evaluated with the average wine temperature in
Figure 8a. The simulation agrees very closely with the experiment, as before for water. The difference after 40 min is only
for both initial temperatures, which corresponds to a relative error of 1.4% or 1.0%, respectively. The largest error is only
, or 2.6%, for
after 20 min.
Figure 8b compares the simulation results for water and wine. Hardly any difference in the average temperature can be observed. The temperature after 40 min differs only by
for both initial temperatures. The experimental data support the simulation results since the temperature for water and wine were also nearly the same in the experiments. The comparison of the material properties of the examined water and aqueous ethanol solution at
yields a deviation of about 0.9% for the density, 2.2% for the specific heat capacity, and 11.5% for the heat conductivity. The investigated wine has a relatively high alcohol content of 13.5%. Since wine usually does not exceed 15.0%, no significant deviating simulation results are expected for other wines. For wines with lower alcohol content, the temperature difference between the wine and water simulation is even more negligible. Consequently, one can assume that deviating fluid properties of wine due to the alcohol content do not significantly affect the heat transfer. Simulation results are therefore valid for all types of non-sparkling wine with negligible or moderate sugar levels. The possible impact of the sugar content was already discussed in
Section 2.2. Furthermore, it would be sufficient to model wine as water. The simulation approach can be applied to comparable non-sparkling beverages with similar properties. In conclusion, the presented simulation accurately represents the warming process of wine in a glass only when considering convection and radiation.
5. Results and Discussion
The validated simulation model was now applied to closely investigate wine warming in the glass. Analyzing the simulation results answers a few fundamental questions. For example, which heating mechanisms dominate, and where do they act? Or, how does the heat intake in wine evolve temporally and locally? The investigation considers the warming of wine with the initial temperature
at room temperature
. Red wine is used in the simulation, but
Section 4 shows that the results apply to many types of non-sparkling wine, excluding sweet wines with high sugar content. Furthermore, a parameter study presents the wine’s temperature increase over time for various combinations of the initial wine and room temperature. The results show how quickly wine warms up under different temperature conditions. Examples are given of how to use these insights in practice. All investigations apply the simulation model, presented in
Section 3, for the problem configuration described in
Section 2.
5.1. Governing Physical Heating Mechanisms of the Warming Process
Initially, the (sensible) heat of the glass is transferred to the wine by conduction. Buoyant flow starts to form. It is characterized by warmer wine with a lower density that rises in the wall area towards the surface. Accelerated fluid velocities lead to increased heat transfer from glass to wine, as cold wine is directed toward the glass. It should be noted that the convective heat transfer includes the conductive contribution, as the two cannot be subdivided at the boundary. The maximum velocity magnitude of the natural convective flow is
m s
−1, which occurs within the first minute of the observation in the vicinity of the wall. The average velocity magnitude in wine peaks at
m s
−1; see
Figure 9b. Warmer liquid rises in the wall area, passes by the surface towards the center, and then returns downwards to the stem wall along positions
to
; see
Figure 9a. When the fluid reaches the lower part of the glass, one can observe a slight increase in velocities due to the narrowing of the glass; see
t = 120 s in
Figure 9b, for example.
The uptake of sensible heat from glass walls and initial natural convection result in the accelerated warming of wine within the first minute; see
Figure 9a. The magnitude of the velocities remains comparably moderate after the initial shocks within the first minute; see
Figure 9b and
Figure 10. The Reynolds number in the liquid domain (
) is
, where
is the kinematic viscosity. The maximum Grashof number is
, where the index W denotes the glass wall temperature, and
is the thermal expansion coefficient. The Grashof number relates viscous forces to natural convective forces and helps to decide whether a turbulent buoyancy is to be expected. Turbulent boundary layers are present for
[
38], which is two orders of magnitude higher than the maximum Grashof number within this work. The assumption of laminar flow in the liquid domain is, hence, valid. Investigating the natural convection closer, it does not seem to be able to equilibrate the temperature in wine. One can observe a stratification in temperatures from two minutes onwards; see
Figure 11. This finding aligns with the findings from the model validation, where the exclusion of wine convection did not alter the simulation outcome considerably.
As the wine starts to cool the wine glass, the latter engages in net radiative heat exchange with surrounding warmer walls of the air domain. The validation in
Figure 7 demonstrates the dominant influence of radiation. Moreover, the temperature difference enables sensible heat transfer from the air at room temperature into the glass; see
Figure 11. Due to the higher density of cooler air, the air starts to fall past the glass and then hovers horizontally away on the table; see
Figure 12. A natural convection cell forms in the air domain. The cooled air tumbles through the problem domain and regains room temperature before it may again pass by the glass.
Figure 11 underlines that air continuously approaches the glass at room temperature. After one hour, the approaching air still has
, which confirms that the natural convection of air in a room can be modeled in a closed cavity with constant wall temperatures. The maximum velocity in the vicinity of the glass is
m s
−1. The corresponding Reynolds number (
) is
and Grashof number is
. Hence, the initial assumption of dominantly laminar airflow seems valid for the scope of this work.
5.2. Spatial and Temporal Heat Flux Analysis
After describing the physical heating effects during the warming process, this section provides answers concerning where and when these effects occur.
Figure 13a,b depict the heat intake
Q from the surrounding air domain. At the liquid surface, convective and radiative heat fluxes add up to the total heat intake. The dominance of radiative heat flux and the overall low magnitude of heat transfer by convection can be explained by a stagnation of the natural convective airflow in the opening of the glass; see
Figure 12. Consequently, a pronounced thermal boundary layer can build up; see
Figure 11. The reduced air temperature trapped in the glass leads to a reduced driving temperature difference for heat conduction at the surface. At the glass–air interface, heat fluxes start to form with continuously decreasing glass temperatures, as, initially, the glass and air both are at
. Radiative and convective heat fluxes at the air–glass interface do not add up to the total heat flux that enters the wine; see
Figure 13b. The difference results from the sensible heat of the glass, which is transferred predominantly within the first minutes of the simulation. The magnitude of heat intake at the glass–wine interface is up to two orders larger than at the air–wine interface. Radiation, again, slightly dominates the heat intake into the glass, which is also reflected in the model validation; see
Figure 7. All in all, the main heat stems from the outside convection of air and the radiative heat exchange of the glass with surrounding walls and the table. The maximum conductive heat flux from the table is
W and, hence, can be neglected. Both radiative and convective heat transfers govern the second warming period for
, when the sensible heat exchange of the glass diminishes. Radiative and convective fluxes reach their maximum after approximately ten minutes. Afterwards, the mechanisms again gradually attenuate as the driving temperature difference between glass and room temperature decreases.
To analyze the local effects of heat transfer, the heat flux at the wine–glass interface (
is integrated over horizontal lines of equal heights, such that one can evaluate the integrated heat flux (
at variable
y-positions.
Figure 14a illustrates these height-dependent heat fluxes at the interface at discrete points in time. Although a dominant heat flux from the stem could be expected, this is not the case. Dominant heating comes from the thin parts of the glass at elevated heights. The heat flux attenuates by one order of magnitude within the first two minutes, where the exchange of sensible heat of the glass dominates the heating. The heat flux from air to the outer wine glass surface at
is analyzed in
Figure 14b. The dominant convective heat flux appears in a small vertical zone of the glass
, where the glass diameter is large. Below this area, the airflow slightly detaches from the glass, which leads to decreased convective heat flux. In the stem and foot area, the cold air regains heat from the glass. On the contrary, the radiative heat exchange can occur within the full range of heights where wine is located on the other side of the wall.
Overall, one can differentiate between two heating periods. Within the first minutes, accelerated heating takes place. The driving mechanisms are the transfer of sensible heat from the glass to the wine and subsequent natural convection. The second period is characterized by the radiative and convective heating of the wine glass that occurs at the outer surface of the glass.
5.3. Temperature Study
After revealing the underlying physical heating phenomena, a parameter study for various combinations of the initial wine and the room temperature was performed. The study included the temperature conditions of and . The warming is discussed more closely for and , which resemble a common room temperature and the temperature on a hot summer day, respectively.
Figure 15 presents the increase of the average wine temperature over time for all combinations. As expected, the temperature rises quicker for higher room temperatures and lower initial temperatures. The previously identified two heating periods primarily determine the temperature development. The initial rapid temperature change due to the intake of the glass’ sensible heat is followed by a moderate, almost constant temperature increase driven by convection and radiation. The rapid warming occurs during the first
min for all conditions. The temperature change over the first minute is about
for
and
for
room temperature. The rate of change is about
at
and
at
after a few minutes.
The following examples are potential practical conclusions drawn from
Figure 15. On a summer day with
, a white wine warms up from
to
in only
min. The wine is warmer than
after
min. Hence, it could be beneficial to reduce the storage temperature at a restaurant or bar to serve the white wine not too warm, considering the time of serving. The glasses could also be cooled in advance to reduce the initial heat transfer from the glass. At the same ambient temperature, red wine poured at
reaches
after only
min. Consequently, it could be desirable to keep red wine relatively cool rather than serving it too warm owing to storage at room temperature. Another scenario could be having a glass of red wine for a nice dinner at home at a room temperature of
: If the red wine was stored in a cellar or refrigerator at
, it warms up to
after
min. This period could be ideal for aerating the wine in the glass until it reaches optimal drinking temperature while finishing the dinner preparation.
6. Conclusions
This study investigated the warming of wine since the temperature significantly affects the wine’s sensory attributes. It provides the physical knowledge to obtain the desired drinking temperature. The presented simulation approach accurately represents the physical process of wine warming in a glass, as validated by experiments with excellent agreement. The simulation must account for heat conduction, convection, and even thermal radiation to model the heat transfer appropriately. Leaving out thermal radiation or natural air convection leads to highly inaccurate results with relative errors of up to 66.3%. The most convective and radiative heat is introduced into the wine at a narrow horizontal band at the outer wall, where the glass diameter is maximal. Accelerated initial heating is governed by natural convection in wine due to the uptake of the sensible heat of the glass. Simulations and experiments suggest that the influence of the alcohol content can be neglected concerning wine warming. Therefore, the results apply to all non-sparkling wines with moderate sugar content for the investigated configuration.
For 150 mL of wine in a medium-sized red wine glass, the temperature increase over time was determined for various combinations of initial wine (storage) and surrounding (room) temperatures. The results can give insight into how to prepare wine in varying ambient climates. The parameter study for arbitrary storage and room temperature configurations should be extended to different filling quantities, glass shapes, and wall thicknesses to obtain broader information on the temperature increase. Future studies could also consider warming wine in a decanter, which is commonly used to aerate wines for a relatively long period. In the future, a framework recently published by the authors [
39,
40] will be used to derive fast and accurate metamodels, so-called digital twins, from the CFD data. The predicted warming time to reach the optimal drinking temperature could then be provided in the form of a lean app that is easily accessible to sommeliers, restaurateurs, and wine lovers.