Article

A Synchronous Tuning Control System for Very Low Frequency Communication Based on Real-Time Impedance Detection

by
Shize Wei
,
Xu Xie
*,
Yuqing Liu
and
Hao Zuo
College of Electronics Engineering, Naval University of Engineering, Wuhan 430030, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2024, 14(22), 10244; https://doi.org/10.3390/app142210244
Submission received: 6 September 2024 / Revised: 31 October 2024 / Accepted: 5 November 2024 / Published: 7 November 2024

Abstract

:
A Very Low Frequency (VLF) communication system is a communication system with limited transmit bandwidth, mainly because the VLF antenna is a high-Q electrically small antenna (ESA) with a narrow effective bandwidth, which limits the improvement of communication rate. To achieve broadband VLF communication, the commonly used method is synchronous tuning technology. In this paper, a synchronous control algorithm based on real-time impedance detection and a synchronous control system structure are proposed. Simulation results show that the method can improve the antenna matching performance, increase the effective bandwidth of the antenna feeder system, and improve the signaling rate.

1. Introduction

A VLF antenna is a typical electrically small antenna [1,2], the electrically small antenna (ESA) is the antenna whose antenna size is much smaller than the wavelength ( l λ ), which can be equivalent to a capacitor or inductor with a small radiation resistance, which also leads to the ESA having a high quality factor, Q. Q is inversely proportional to the antenna bandwidth, so the electrically small antenna with high Q is a narrow band antenna. Chu’s theorem gives the formula for calculating the Q value of electrically small antennas as follows [1,2,3].
Q = 1 + 3 k 2 a 2 ( k a ) 3 ( 1 + k 2 a 2 )
k is the wave number, k = 2 π / λ , and as shown in Figure 1, a is the radius of the sphere that exactly surrounds the antenna. It can be known from Equation (1) that when the antenna electrical size decreases, the Q value will increase and the antenna bandwidth will become narrow. When the antenna size decreases to less than λ / 2 π , the Q value will increase greatly.
At present, the VLF communication system mainly uses an MSK (Minimum Shift Keying) signal source [4,5], and the traditional VLF transmitter system uses a fixed tuning network, and the resonant frequency of the antenna feeder system is at the center frequency of the MSK signal. In order to ensure that the transmitted signal has enough power, the symbol rate of the MSK signal will be very low, which also leads to a low communication rate.
S M S K = c o s ( 2 π f c t + π a k 2 T s t + φ k ) , ( k 1 ) T s t k T s
Formula (2) is the expression of MSK signal [6], where f c is the carrier frequency; a k = ± 1 (corresponding to the input symbol is “1” or “0”); T s is the symbol width; φ k is the initial phase of the kth symbol, which is invariant in one symbol width. When the input symbol is “1”, a k = + 1 , frequency is f h = f c + 1 / 4 T s , and when the input symbol is “0”, a k = 1 , frequency is f l = f c 1 / 4 T s and symbol rate is R B = 1 / T s . In this paper, f h is the “mark” frequency and f l is the “space” frequency.
According to the Shannon formula C = B   log 2 1 + S / N [6], under the condition that SNR is almost unchanged, as the communication rate increases, the communication capacity increases, and the bandwidth occupied by the signal also gradually increases. However, when the signal bandwidth exceeds the available bandwidth of the antenna feeder system, the signal will be greatly attenuated and the information carried by the waveform will be lost.
Therefore, the reason that limits the improvement of the communication rate lies in the narrowband characteristics of the high-Q electric small antenna. In order to enhance the effective bandwidth and optimize the communication rate of the VLF system, two primary approaches can be employed. One involves augmenting the series resistance between the antenna and transmitter; however, this comes at a cost of reduced efficiency, which may impact the overall communicative capability of the system [7].
Another approach to enhance the effective bandwidth is synchronous tuning technology [8], enabling the feeder system to dynamically tune to both the “space” frequency f l and “transmission” frequency f h of MSK signals instead of being statically tuned at the center frequency. This technique effectively broadens the system’s effective bandwidth and enhances communication speed without compromising antenna efficiency, as depicted in Figure 2 [9,10,11,12,13,14]. Presently, countries such as the United States and Australia have embraced synchronous tuning technology, achieving communication speeds ranging from 200 bps to 1000 bps or even higher [15].
This technology has been developing continuously for many years and has achieved good results, including magnetic saturation switching amplifier methods, frequency shift keying methods based on electronic switching capacitors, high current variable inductor methods and so on [16,17,18,19,20,21]. Based on the above methods, A synchronous tuning control strategy for VLF communication based on real-time impedance detection is proposed in this paper. The resonant frequency of antenna feeder system is controlled by symbol signal and impedance detection result. This method can quickly determine the inductance of antenna feeder system and then control the corresponding inductor in the controlled inductor array.

2. Basic Structure of the System

As shown in Figure 3, C a is the equivalent capacitor of the VLF antenna, R a is the equivalent radiation resistor of the VLF antenna, L 0 is the fixed tuning inductor, and Δ L is the variable inductor, which is specifically composed of different combinations of controlled inductor arrays ( L c n ) in this paper. When the frequency of the MSK signal is f h , the tuning inductance required for this system is L 0 and Δ L = 0 . When the frequency of the MSK signal is f l , the required tuning inductance for this system becomes L 0 + Δ L, Δ L = 1 / ( ω l 2 C a ) L 0 .
Figure 4 shows the structure diagram of the synchronous Tuning Control described in this paper. The system is mainly composed of the controlled inductance matrix, the driver and switch matrix, and the control matrix. L 0 is the fixed inductor and L C 1 and L C 2 are the controlled inductors, which form the primary loop through the MSK signal, and when the MSK signal carrier frequency is f h , all IGBTs are in the conduction state [22,23]. At this time, only the inductor L 0 is in operation in the system. Then, the resonant frequency of the antenna feeder system is adjusted to f h when the MSK signal carrier frequency is f l . The IGBT of the corresponding numerical inductor Lcn is controlled to be turned off, so that the inductance in the antenna feeder system is L 0 + i = 1 n L c n , n N + , and the resonant frequency of the antenna feeder system is adjusted to f l .
As shown in Figure 4, the key part of the system is the control matrix, and the controller is used to control the enable state of each logic unit. Now, the function of the logic control unit is mainly expounded. As shown in Figure 5, each output port of the controller corresponds to one logic control unit, and each logic control unit is composed of two XOR gates and one AND gate. The AND gate input is the control signal output from the controller port and the demodulated MSK symbol signal, the XOR gate input to the left of the AND gate is logic 1 and the control signal output from the controller port, and the XOR gate input above is the AND gate and the logic output of the XOR gate to the left of the AND gate. The logic truth table is as follows [24]:
As can be seen from Table 1, when the controller outputs logic 0, the logic output of F is always 1, which is not affected by the symbol signal. At this time, the IGBT always remains in the conduct state, and the logic 0 output by the controller is called the failure instruction.
When the controller outputs logic 1, the logic output of F is controlled by the symbol signal. When the symbol is 1, F is 1, and when the symbol is 0, F is 0. At this time, the IGBT is in the symbol signal control state, and the logic 1 output by the controller is called the enabling instruction.
After Δ L is calculated, the corresponding controller port is determined by the table look-up method, and the corresponding port will always remain in the enabled state.

3. Synchronous Control Strategy Based on Real-Time Impedance Detection

Basic condition: The high level of the control signal corresponds to the high frequency point f h of the MSK signal, and the low level corresponds to the low frequency point, f l , of the MSK signal. The system is resonant at high frequency by adjusting the fixed tuning inductor, L 0 , and the initial state of the power electronic switches at both ends of the controlled inductor is conduction.
Figure 6 shows the flow of synchronous control strategy based on real-time impedance detection (hereinafter referred to as SYNT-RTID synchronous control strategy). The calculation process of the controlled inductance, ΔL, is as follows [16].
Z = U I = U φ u I φ i = Z φ Z = z φ Z
Z = U I = R + j ( ω L 1 ω C )
ω L 1 ω C = z s i n φ Z
L = z s i n φ Z ω + 1 ω 2 C
Δ L = I m [ Z ] ω = z s i n φ Z ω
As shown in Figure 6, after ΔL is obtained, the appropriate combination of controlled inductors is selected by the table look-up method. Each ΔL corresponds to a group of controlled inductor combinations, and each controlled inductor corresponds to the control port of a controller to ensure that the controller can control the corresponding number of inductors.
The actual accuracy of the inductor is difficult to reach the accuracy of the theoretical value. At the same time, considering the cost, the accuracy of the inductor should also be controlled within a reasonable range. The VLF communication system is a narrowband system, and the accuracy of the inductor has a great impact on the system. We mainly discuss the influence of the inductor accuracy on the power factor angle, φ , and the antenna radiation efficiency of the antenna feeder system.
For the convenience of discussion, in this section, the antenna equivalent capacitance is C a =   39.79   n F , the antenna equivalent radiation resistance is R a = 1   Ω , the MSK signal center frequency, f 0 , are 15 kHz, 20 kHz, 25 kHz, and 30 kHz, respectively, and the symbol rate, R B , is 200 bps, 300 bps, 500 bps, 700 bps, and 900 bps. L 0 is the amount of tuning inductance required by the antenna fed system at frequency f h resonant, and L l is the amount of tuning inductance required by the antenna fed system at frequency f l resonant, and Δ L = L l L 0 . The heat loss is ignored in this paper.

3.1. Power Factor Angle of Antenna Feeder System

The power factor c o s φ is the ratio of active power, P, to apparent power, S, in an AC circuit, commonly represented as λ . φ is referred to as the power factor angle and can be obtained by subtracting the phase of port current from the phase of port voltage [25,26,27]. Let us assume:
U = U φ u
I = I φ i
φ = φ u φ i
According to Equations (8)–(10), we can obtain the power factor angle, φ , of the antenna feeder system, as shown in Figure 7 and Figure 8.
According to Figure 7 and Figure 8, when the accuracy of L 0 and L l is n × 10 2 m H , the power factor angle, φ , of the antenna feeder system is approximately between −40° and +40°, which translates to a power factor of approximately 0.766 < c o s φ < 1 . When the accuracy of L 0 and L l is n × 10 3 m H , the power factor angle, φ , of the antenna feeder system is approximately between −4° and 4°, which translates to a power factor of approximately 0.998 < c o s φ < 1 . It can be seen that the improvement of accuracy greatly reduces the power factor angle PHI of the antenna feeder system, and we can consider that the voltage signal and the current signal are approximately in phase. In general, c o s φ > 0.8 is required [27].

3.2. Radiation Efficiency of the Antenna

The apparent power, S, of the antenna feeder system includes the active power, P a , and the reactive power, Q. In this paper, P a is the antenna radiated power [4].
P a = R a × I 2
Q = | ω L 1 ω C a | × I 2
η = P a P a + Q = R a R a + | ω L 1 ω C a |
It can be seen from Figure 9 and Figure 10 that when the accuracy of L 0 and L l is n × 10 2 m H (n is a positive integer, for example, n = 1, which means that the inductance is N), the variation range of antenna radiation efficiency is about 50% to 95%, and the variation range of antenna radiation efficiency is large and the decline is obvious. When the accuracy of L 0 and L l is n × 10 3 m H , the variation range of antenna radiation efficiency is about 91% to 100%.
Considering that there are many factors that affect the performance of the communication system, the superposition of multiple factors may lead to a serious degradation of the system performance, so the influence of the accuracy of the inductor on the system performance should be as little as possible. Combining Section 3.1 and Section 3.2 , the accuracy of L 0 and L l is at least n × 10 3   m H under the proposed conditions in this paper, and at this time, we can obtain Table 2 and Table 3.
Because Δ L = L l L 0 , Table 4 can be obtained. Δ L is obtained by combining the inductor array ( L C n , n N + ), which is mainly controlled by the controller and the demodulated symbol signal. Table 4 is the number table required by the look-up table method. The inductor array combination corresponding to Δ L can be determined according to the actual engineering, such as installation space, cost, etc., which will not be further elaborated in this paper.

4. Simulation Analysis

According to Figure 4, the simulation model can be established, and the simulation parameters are: fixed inductors L 0 = 1.58   m H , L C 1 = 10   μ H , L C 2 = 5   μ H , L C 3 = 30   μ H ; the MSK signal center frequency is f 0 = 20   k H z ; the antenna equivalent capacitance is C a = 39.79   n F ; the antenna equivalent radiation resistance is R a = 1   Ω ; and symbol rates are 200 bps, 500 bps, 1000 bps, respectively. The simulation results are as follows.
As illustrated in Figure 11a, Figure 12a and Figure 13a, an increase in the communication rate results in a decline of the peak voltage signal across the equivalent radiation resistance of the very low frequency antenna during traditional tuning, decreasing from approximately 40.9 V to 34.82 V. Concurrently, the fluctuations within the envelope become increasingly pronounced, with its minimum value dropping from around 38.51 V to 20.98 V. Conversely, as depicted in Figure 11b, Figure 12b and Figure 13b, under the SYNT-RTID synchronization control strategy, the peak voltage signal on the equivalent radiation resistance remains stable between 43.72 V and 43.93 V as communication rates rise, exhibiting both a consistent peak value and a constant envelope profile. It is evident that signals governed by the SYNT-RTID control strategy maintain significantly higher peak values compared to those observed during traditional tuning while also preserving a steady envelope.
However, as illustrated in Figure 11b, Figure 12b and Figure 13b, the signal experiences a period of detuning. This phenomenon arises from the fact that, according to the previously described control strategy flowchart, real-time impedance measurement necessitates a certain duration; during this time, both the amplitude and phase of the signal do not exhibit abrupt changes when out of tune but instead undergo gradual variations. Consequently, only those impedance measurements taken after stabilization of amplitude and phase yield accurate results. At this juncture, the controller within the tuning control unit will issue corresponding enable control instructions to the logic gate unit. Upon receiving these enable instructions, the logic gate unit is primarily governed by code word sequence signals and subsequently outputs tuning control signals to the switching device. Following initial impedance measurement, which identifies necessary enabling for specific logic gates, subsequent controls are predominantly managed by code word sequence signals; thus, ensuring that at this stage, the signal remains consistently in resonance with a stable envelope.
The blue curve in Figure 11b, Figure 12b and Figure 13b illustrates the control signal CTR output by the tuning control unit. As depicted, the impedance measurement times are approximately 2 ms, 2 ms, and 1.5 ms, all of which are less than two code word widths; consequently, this strategy enables rapid system tuning within these constraints. During the actual message transmission process, the code word sequence is inherently random, and its overall duration extends beyond just a few milliseconds. The likelihood of encountering at least two consecutive ‘0’ code words is significantly high; therefore, any energy loss attributable to impedance measurement time in practical applications can be considered negligible.

5. Conclusions

This paper conducts a comprehensive analysis of inductor accuracy, establishing the appropriate precision requirements under specified conditions. Additionally, the methodology presented herein can be employed to ascertain the necessary inductor accuracy for practical applications. Furthermore, we propose a synchronous tuning control strategy for VLF communication based on real-time impedance detection, ensuring that the antenna feed system resonates with MSK signals in real time. As communication rates increase, the improvement effect of synchronous tuning on the voltage signal waveform of the equivalent radiation resistor of the VLF antenna will be more obvious. Consequently, this VLF communication synchronous tuning control system and its associated strategy can effectively expand the bandwidth of the antenna feed system and enhance communication rates within VLF transmission systems.

Author Contributions

Conceptualization, S.W.; Methodology, S.W.; Software, Y.L.; Validation, S.W.; Formal analysis, H.Z.; Resources, H.Z.; Writing—original draft, S.W.; Writing—review & editing, X.X.; Supervision, X.X.; Funding acquisition, X.X. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Basic Strengthening Program Technological Field Fund, grant number 2021-JCJQ-JJ-0749.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author. The data are not publicly available due to privacy.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Wen, W.F. Research on Miniaturized HF Ultra-HF Wideband Antenna and Matching Network. Master’s Thesis, University of Electronic Science and Technology, Chengdu, China, 2024. [Google Scholar]
  2. Dan, D. Research on Wideband and Miniaturization of Low-Frequency Antenna. Master’s Thesis, University of Electronic Science and Technology, Chengdu, China, 2014. [Google Scholar]
  3. Fujimoto, K.; Hirasawa, K.; Henderson, A.; Ames, J.R. Small Antenna; National Defense Industry Press: Beijing, China, 1991. [Google Scholar]
  4. Liu, C.; Jiang, H.; Huang, J.H. Very Low Frequency Communication; Haichao Publishing House: Beijing, China, 2008; p. 122. [Google Scholar]
  5. Sun, Y.; Yin, L.; Xiang, X. MSK engineering implementation method of digital modulation signal demodulation. J. Comput. Appl. Softw. 2019, 36, 5. [Google Scholar]
  6. Fan, C.; Cao, L. Communication Principle; National Defense Industry Press: Beijing, China, 2006. [Google Scholar]
  7. Watt, A.D. VLF Radio Engineering; Pergamon: Bergama, Turkey, 1967. [Google Scholar]
  8. Wolff, H. High-Speed Frequency-Shift Keying of LF and VLF Radio Circuits. IRE Trans. Commun. Syst. 1957, 5, 29–42. [Google Scholar] [CrossRef]
  9. Jin, G.; Dong, Y. MSK synchronization based on FPGA tuning study. Microcomput. Inf. 2012, 28, 52–53. [Google Scholar]
  10. Hartley, H. Electronic Broad Banding of VLF/LF Antennas for FSK Radio Communication. IEEE Trans. Commun. Technol. 1971, 19, 555–561. [Google Scholar] [CrossRef]
  11. Zhang, W.; Zheng, L.; Dong, Y. Very low frequency transmitting antenna dynamic tuning bandwidth study. J. Ship Electr. Eng. 2009, 10, 4. [Google Scholar] [CrossRef]
  12. Dong, Y.; Liu, C. Dynamic tuning VLF antenna performance. J. Nav. Eng. Univ. 2010, 22, 98–102. [Google Scholar]
  13. Jin, G.; Dong, Y. VLF emission system synchronous tuning study. J. Mod. Electron. Technol. 2011, 34, 3. [Google Scholar]
  14. Ling, J.; Dong, Y.; Xu, H. Very low frequency transmitting system performance simulation. J. Radio Commun. Technol. 2015, 74–76. [Google Scholar] [CrossRef]
  15. Dong, Y.; Jiang, Y.; Zhang, J. VLF emission system based on MSK spectrum frequency characteristic study. J. Radio Sci. J. 2010, 3, 6. [Google Scholar]
  16. Firman, C.M. Synchronized Turn-Off of VLF Antennae: US19720222194. U.S. Patent 3904966A, 18 June 2024. [Google Scholar]
  17. Johannessen, P.R.; Planckp, V. Antenna Tuning System and Method. U.S. Patent 4689803, 1 September 1987. [Google Scholar]
  18. Johnson, L.J. Magnetic Amplifier Switchfor Automatic Tuning of VIF Transmitting Antenna. U.S. Patent 5034697, 23 July 1991. [Google Scholar]
  19. Ivan, W.; Ivan, W.; Guy, B. Switchable Inductor for Strong Currents and Antenna Tuning Circuit Provided with at Least One Such Inductance: FR19920005722. U.S. Patent FR2691308A1, 5 May 2024. [Google Scholar]
  20. Simpson, T.; Roberts, M.; Berg, E. Developing a broadband circuit model for the Cutler VLF antenna. In Proceedings of the Antennas & Propagation Society International Symposium, Boston, MA, USA, 8–13 July 2001. [Google Scholar] [CrossRef]
  21. Berg, E.C.; Roberts, M.A.; Simpson, T.L. Dual-frequency distortion predictions for the Cutler VLF array. Aerosp. Electron. Syst. IEEE Trans. 2003, 39, 1016–1034. [Google Scholar] [CrossRef]
  22. Volke, A.; Hornkamp, M. IGBT Modules: Technology, Drivers and Applications; Infineon Technologies AG: Munich, Germany, 2012. [Google Scholar]
  23. Khanna, V.K. Insulated Gate Bipolar Transistor IGBT Theory and Design; Wiley-IEEE Press: Hoboken, NJ, USA, 2003. [Google Scholar] [CrossRef]
  24. Yan, S. (Ed.) Foundation of Digital Electronic Technology; Higher Education Press: Beijing, China, 2006. [Google Scholar]
  25. Yang, D.; Liu, R.; Zhao, L. Three-phase high power factor rectifier current control. J. Electrotech. 2000, 15, 5. [Google Scholar]
  26. Wu, X. The Improvement of Circuit Power Factor. In Proceedings of the 2nd International Conference on Material Science, Energy and Environmental Engineering (MSEEE 2018), Xi’an, China, 16–17 August 2018. [Google Scholar] [CrossRef]
  27. Zu, Y.; Li, W.; Lv, Y. Fundamentals of Circuit Analysis, 2nd ed.; Publishing House of Electronics Industry: Beijing, China, 2014. [Google Scholar]
Figure 1. Schematic diagram of the ESA.
Figure 1. Schematic diagram of the ESA.
Applsci 14 10244 g001
Figure 2. Schematic of the effective bandwidth of a high-Q ESA (The black curve represents the antenna bandwidth, while the yellow and red curves represent the bandwidth occupied by the MSK signal).
Figure 2. Schematic of the effective bandwidth of a high-Q ESA (The black curve represents the antenna bandwidth, while the yellow and red curves represent the bandwidth occupied by the MSK signal).
Applsci 14 10244 g002
Figure 3. Equivalent circuit diagram of VLF signaling system (ignoring loss resistance) [17].
Figure 3. Equivalent circuit diagram of VLF signaling system (ignoring loss resistance) [17].
Applsci 14 10244 g003
Figure 4. Schematic diagram of the synchronous control system described.
Figure 4. Schematic diagram of the synchronous control system described.
Applsci 14 10244 g004
Figure 5. Logic control unit diagram (A is a fixed logic instruction, D and E are the outputs of XOR and AND gates, respectively, and F is the final control instruction output by the logic control unit.).
Figure 5. Logic control unit diagram (A is a fixed logic instruction, D and E are the outputs of XOR and AND gates, respectively, and F is the final control instruction output by the logic control unit.).
Applsci 14 10244 g005
Figure 6. Flowchart of synchronous control strategy based on real-time impedance detection.
Figure 6. Flowchart of synchronous control strategy based on real-time impedance detection.
Applsci 14 10244 g006
Figure 7. The power factor angle, φ , of the antenna feeder system when the carrier frequency of the MSK signal is f h (a) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 2 m H ; (b) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 3 m H .
Figure 7. The power factor angle, φ , of the antenna feeder system when the carrier frequency of the MSK signal is f h (a) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 2 m H ; (b) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 3 m H .
Applsci 14 10244 g007
Figure 8. The power factor angle, φ , of the antenna feeder system when the carrier frequency of the MSK signal is f l (a) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 2 m H ; (b) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 3 m H .
Figure 8. The power factor angle, φ , of the antenna feeder system when the carrier frequency of the MSK signal is f l (a) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 2 m H ; (b) The power factor angle, φ , of the antenna feeder system when the accuracy of L 0 reaches n × 10 3 m H .
Applsci 14 10244 g008
Figure 9. The antenna radiation efficiency when the carrier frequency of the MSK signal is f h . (a) The antenna radiation efficiency when the accuracy of L 0 reaches n × 10 2 m H ; (b) the antenna radiation efficiency when the accuracy of L 0 reaches n × 10 3 m H .
Figure 9. The antenna radiation efficiency when the carrier frequency of the MSK signal is f h . (a) The antenna radiation efficiency when the accuracy of L 0 reaches n × 10 2 m H ; (b) the antenna radiation efficiency when the accuracy of L 0 reaches n × 10 3 m H .
Applsci 14 10244 g009
Figure 10. The antenna radiation efficiency when the carrier frequency of the MSK signal is f l . (a) The antenna radiation efficiency when the accuracy of L l reaches n × 10 2   m H ; (b) the antenna radiation efficiency when the accuracy of L l reaches n × 10 3   m H .
Figure 10. The antenna radiation efficiency when the carrier frequency of the MSK signal is f l . (a) The antenna radiation efficiency when the accuracy of L l reaches n × 10 2   m H ; (b) the antenna radiation efficiency when the accuracy of L l reaches n × 10 3   m H .
Applsci 14 10244 g010
Figure 11. Time domain waveforms of the voltage signals at both ends of the R a under different tuning modes when the communication rate is 200 bps. (a) Fixed tuning; (b) when the SYNT-RTID synchronous control strategy is used.
Figure 11. Time domain waveforms of the voltage signals at both ends of the R a under different tuning modes when the communication rate is 200 bps. (a) Fixed tuning; (b) when the SYNT-RTID synchronous control strategy is used.
Applsci 14 10244 g011aApplsci 14 10244 g011b
Figure 12. Time domain waveforms of the voltage signals at both ends of the R a under different tuning modes when the communication rate is 500 bps. (a) Fixed tuning; (b) when the SYNT-RTID synchronous control strategy is used.
Figure 12. Time domain waveforms of the voltage signals at both ends of the R a under different tuning modes when the communication rate is 500 bps. (a) Fixed tuning; (b) when the SYNT-RTID synchronous control strategy is used.
Applsci 14 10244 g012aApplsci 14 10244 g012b
Figure 13. Time domain waveforms of the voltage signals at both ends of the R a under different tuning modes when the communication rate is 1000 bps. (a) Fixed tuning; (b) when the SYNT-RTID synchronous control strategy is used.
Figure 13. Time domain waveforms of the voltage signals at both ends of the R a under different tuning modes when the communication rate is 1000 bps. (a) Fixed tuning; (b) when the SYNT-RTID synchronous control strategy is used.
Applsci 14 10244 g013aApplsci 14 10244 g013b
Table 1. Logic truth table.
Table 1. Logic truth table.
AB: Symbol SignalC: Controller SignalDEF
110101
100101
111011
101000
Table 2. Inductance values L 0 /mH corresponding to different Baud rates and center frequencies.
Table 2. Inductance values L 0 /mH corresponding to different Baud rates and center frequencies.
f0 15 kHz20 kHz25 kHz30 kHz
L0
RB
100 bps2.8201.5881.0170.706
200 bps2.8111.5841.0140.705
300 bps2.8011.5801.0120.704
400 bps2.7921.5761.010.703
500 bps2.7831.5721.0080.701
600 bps2.7741.5681.0060.700
700 bps2.7641.5641.0040.699
800 bps2.7551.5601.0020.698
900 bps2.7461.5561.0000.697
1000 bps2.7371.5520.9980.696
Table 3. Inductance values L l /mH corresponding to different Baud rates and center frequencies.
Table 3. Inductance values L l /mH corresponding to different Baud rates and center frequencies.
f0 15 kHz20 kHz25 kHz30 kHz
Ll
RB
100 bps2.8391.5951.0210.709
200 bps2.8481.5991.0230.710
300 bps2.8581.6041.0250.711
400 bps2.8671.6081.0270.712
500 bps2.8771.6121.0290.713
600 bps2.8871.6161.0310.714
700 bps2.8971.6201.0330.716
800 bps2.9061.6241.0350.717
900 bps2.9161.6281.0370.718
1000 bps2.9261.6321.0390.719
Table 4. Inductance values ΔL/μH corresponding to different Baud rates and center frequencies.
Table 4. Inductance values ΔL/μH corresponding to different Baud rates and center frequencies.
f0 15 kHz20 kHz25 kHz30 kHz
ΔL
RB
100 bps19743
200 bps371595
300 bps5724137
400 bps7532179
500 bps94402112
600 bps113482514
700 bps133562917
800 bps151643319
900 bps170723721
1000 bps189804123
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Wei, S.; Xie, X.; Liu, Y.; Zuo, H. A Synchronous Tuning Control System for Very Low Frequency Communication Based on Real-Time Impedance Detection. Appl. Sci. 2024, 14, 10244. https://doi.org/10.3390/app142210244

AMA Style

Wei S, Xie X, Liu Y, Zuo H. A Synchronous Tuning Control System for Very Low Frequency Communication Based on Real-Time Impedance Detection. Applied Sciences. 2024; 14(22):10244. https://doi.org/10.3390/app142210244

Chicago/Turabian Style

Wei, Shize, Xu Xie, Yuqing Liu, and Hao Zuo. 2024. "A Synchronous Tuning Control System for Very Low Frequency Communication Based on Real-Time Impedance Detection" Applied Sciences 14, no. 22: 10244. https://doi.org/10.3390/app142210244

APA Style

Wei, S., Xie, X., Liu, Y., & Zuo, H. (2024). A Synchronous Tuning Control System for Very Low Frequency Communication Based on Real-Time Impedance Detection. Applied Sciences, 14(22), 10244. https://doi.org/10.3390/app142210244

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop