Next Article in Journal
Adaptive Solar Power Forecasting based on Machine Learning Methods
Next Article in Special Issue
Experimental Efficiency Analysis of a Photovoltaic System with Different Module Technologies under Temperate Climate Conditions
Previous Article in Journal
An Improved Neural Network Cascade for Face Detection in Large Scene Surveillance
Previous Article in Special Issue
A Hybrid Forecasting Method for Solar Output Power Based on Variational Mode Decomposition, Deep Belief Networks and Auto-Regressive Moving Average
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Numerical Analysis for Thermal Performance of a Photovoltaic Thermal Solar Collector with SiO2-Water Nanofluid

by
Ali J. Chamkha
1,2 and
Fatih Selimefendigil
3,*
1
Mechanical Engineering Department, Prince Sultan Endowment for Energy and Environment, Prince Mohammad Bin Fahd University, Al-Khobar 31952, Saudi Arabia
2
RAK Research and Innovation Center, American University of Ras Al Khaimah, Ras Al Khaimah P.O. Box 10021, UAE
3
Department of Mechanical Engineering, Celal Bayar University, Manisa 45140, Turkey
*
Author to whom correspondence should be addressed.
Appl. Sci. 2018, 8(11), 2223; https://doi.org/10.3390/app8112223
Submission received: 17 October 2018 / Revised: 2 November 2018 / Accepted: 5 November 2018 / Published: 11 November 2018

Abstract

:
Numerical analysis of a photovoltaic-thermal (PV/T) unit with SiO 2 -water nanofluid was performed. The coupled heat conduction equations within the layers and convective heat transfer equations within the channel of the module were solved by using the finite volume method. Effects of various particle shapes, solid volume fractions, water inlet temperature, solar irradiation and wind speed on the thermal and PV efficiency of the unit were analyzed. Correlation for the efficiencies were obtained by using radial basis function neural networks. Cylindrical shape particles were found to give best performance in terms of efficiency enhancements. Total efficiency enhances by about 7.39% at the highest volume fraction with cylindrical shape particles. Cylindrical shape particle gives 3.95% more enhancement as compared to spherical ones for the highest value of solid particle volume fraction. Thermal and total efficiency enhance for higher values of solid particle volume fraction, solar irradiation and lower values of convective heat transfer coefficient and inlet temperature. The performance characteristics of solar PV-thermal unit with radial basis function artificial neural network are found to be in excellent agreement with the results obtained from computational fluid dynamics modeling.

1. Introduction

Nanofluids are composed of base fluid such as water, ethylene glycol or mineral oil and added solid nano-sized particles. They have been extensively used in different thermal engineering applications [1,2,3,4,5,6,7,8,9,10,11,12,13,14]. The nano-sized particle could be metallic or non-metallic such as Cu, Ag, CuO, Al 2 O 3 , TiO 2 , SiO 2 with average particle size less than 100 nm. Higher thermal conductivity of the nanoparticles increase the thermal conductivity of the heat transfer fluid and enhances the thermal performance. Size, shape and type of the particles are effective for the thermal conductivity enhancement of nanofluids. Thermophysical properties are derived from theoretical or experimental studies for nanofluids containing various particle types, shapes and sizes for different temperatures. Generally, a small amount of particle addition of the base fluid results in higher heat transfer enhancements. Application of the nanofluids for the thermal engineering systems are diverse such as in refrigeration, microelectromechanical systems (MEMs), cooling of nuclear reactors, thermal management of fuel cells, cooling of hydrogen storage, heat exchangers and many others. In the refrigeration application, nano additives are added to compressor oil to increase the coefficient of performance. In some applications, solid nano particles are added to the refrigerants. In heat exchanger design, more compact and lightweight structures can be designed when heat transfer fluid has a higher thermal conductivity with the addition of nanoparticles.
Application of nanotechnology in the field of renewable energy is growing. There are many studies related to the nanofluids application in solar power. A review for the application of the nanofluid in solar energy was presented in the study by Mahian et al. [15]. Using nanofluids in solar collectors and solar water heaters and their impacts on the efficiency and environmental effects were also discussed. Mahian et al. [16] performed analytical study for the performance of a solar collector with various types of nanofluids such as Cu/water, Al 2 O 3 /water, TiO 2 /water, and SiO 2 /water nanofluids with particle size of 25 nm. System with Cu/water nanofluid has lowest entropy generation rate whereas Al 2 O 3 /water nanofluid has the highest heat transfer coefficient as compared to other nanofluids. In the study by Meibodi et al. [17], an experimental investigation was performed for a flat plate solar collector with SiO 2 /ethylene glycol (EG-water nanofluid. Various mass flow rates and particle volume fraction up to 1% were tested. It was observed that, despite the low conductivity of SiO 2 nanoparticles, solar collector efficiency was found to be enhanced with nanofluid. Chen et al. [18] studied the effects of inclusion of Au nanoparticles for the photo-thermal conversion performance numerically and experimentally for various solar intensities and particle volume fractions. The absorption efficiency was found to increase with higher nanoparticle volume fractions. Effects of SiO 2 nanoparticles in solar collector tubes were numerically and experimentally studied by Yan et al. [19]. Heat transfer rate was found to be higher for nanofluid and, due to nanofluid agglomeration, the heat transfer rate deteriorates for longer operation times.
In the Photovoltaic/Thermal modules (PV/T), heat and electricity are produced by using photovoltaic and heat extraction units. A review study for the application of nanofluids in PV/T systems and discussions about effective parameters and effectiveness of nanofluids were presented in [20]. Al-Waeli et al. [21] performed an experimental study for the determination of effective thermophyscial properties of water containing SiC nanoparticles that was used as a cooler for PV/T system. It was observed that thermal conductivity enhancements are about 8.2% for the temperature range of 25–60 C. The electrical efficiency with 3 wt % of SiC nanofluid results in electrical efficiency enhancements of 24.1% and it was observed that the nanofluids were stable for long use. In the study by Hassani et al. [22], a new cascade PV/T module was proposed with separate channels. Two nanofluids were used to enhance the electrical and thermal performance of the PV/T module. Jing et al. [23] investigated the effects of silica/water nanofluids on the efficiency of PV/T module. Various sizes of nanoparticles, concentrations and flow velocity were considered. Optimum operational parameters for the economical considerations were also obtained.
In the present study, efficiency of a PV/T module with SiO 2 -water nanofluid was numerically investigated for nanoparticle properties (shape, volume fraction) and for different operating conditions. Despite the low conductivity of SiO 2 nanoparticles as compared to other particles, its low cost, favorable physical and chemical properties makes it attractive for usage with water. Artificial neural networks with radial basis functions are used to obtain the correlations for efficiencies of PV-thermal module.

2. Mathematical Modeling

Figure 1 shows a schematic representation of a PV-thermal module which is composed of several layers and a channel in which SiO 2 -water nanofluid is flowing throughout. Thermophysical properties of the layers in the PV-thermal module is given in Table 1.
An energy balance between the solar irradiance and heat transfer to the heat transfer fluid with nanoparticles is considered. Within the layers of the PV-module, the heat conduction equation is used.
Within the layers of the PV-thermal module steady state, the heat conduction equation is valid and is given by the following equation:
. k l a y e r T = 0 .
Navier–Stokes and energy equations for the fluid flow and heat transfer in the channel are given by the following equations:
. ( u ) = 0 ,
ρ u . u = - p + μ 2 u ,
ρ c p u . T = . k T .
The PV cell electrical efficiency is given by the following equation:
η p v = η T r e f 1 - β r e f T p v - T r e f .
Thermal efficiency is defined as the ratio of the energy gained by the collector divided by the total incident energy
η t h = m ˙ c p T o u t - T i n G .
  • For the upper surface, the heat flux boundary condition with incident radiation and convective heat loss due to wind (heat transfer coefficient h and wind speed are related) is considered:
    q = q - h A ( T u p p e r - T ) .
  • Among the layers of of the PV-module, heat flux continuity is utilized, q l a y e r , n + 1 = q l a y e r , n .
  • At the inlet of the channel, temperature and velocity are uniform, u = u 0 , v = 0 , T = T c .
  • At the exit of the channel, gradients in the x-direction are set to zero, u x = 0 , v x = 0 , T x = 0 .

2.1. Nanofluid Thermophysical Properties

SiO 2 -water nanofluid was used in this study and the thermo-physical properties are given in Table 2 [24]. The effective density, specific heat, thermal expansion coefficient of the nanofluid are given by the following formulas:
ρ n f = ( 1 - ϕ ) ρ f + ϕ ρ p ,
( ρ c p ) n f = ( 1 - ϕ ) ( ρ c p ) f + ϕ ( ρ c p ) p ,
( ρ β ) n f = ( 1 - ϕ ) ( ρ β ) f + ϕ ( ρ β ) p ,
where the subscripts f, n f and p denote the base fluid, nanofluid and solid particle, respectively.
The effective thermal conductivity of the nanofluid includes the effect of Brownian motion. In this model, the effects of particle size, particle volume fraction and temperature dependence are taken into account and it is given by the following formula [25]:
k n f = k s t + k B r o w n i a n ,
where k s t is the static thermal conductivity as given by [26]
k s t = k f ( k p + 2 k f ) - 2 ϕ ( k f - k p ) ( k p + 2 k f ) + ϕ ( k f - k p ) .
The interaction between the nanoparticles and the effect of temperature are included in the models as
k B r o w n i a n = 5 × 10 4 × 1 . 9526 × ( 100 ϕ ) - 1 . 4594 ϕ ρ f c p , f κ b T ρ p d p f ( T , ϕ ) ,
where the function f is given in [25].
The effective viscosity model of the nanofluid was given in [27]
μ n f = μ f 1 1 - 34 . 87 d p d f - 0 . 3 ϕ 1 . 03 ,
where the average particle size of the fluid is given as [27]:
d f = 6 M N π ρ f 1 / 3 ,
with M and N denoting the molecular weight and Avogadro number.

2.2. Nanoparticle Shape Effect

The above given correlations in Equations (10)–(14) are used for the description of effective thermal conductivity for spherical particles. The effective thermal conductivity and viscosity of the nanofluid using non-spherical nanoparticle shape are defined using the following formulas:
k n f = k f 1 + C k ϕ , μ n f = μ f 1 + A 1 ϕ + A 2 ϕ 2 ,
where the constant coefficients for different nanoparticle shapes are defined as in Table 3 [28,29].

2.3. Solution Method

The finite volume method was used to solve the governing equations along with the boundary conditions. A general convection-diffusion equation for a scalar transport variable Ψ has the following form:
. ρ u Ψ = . Γ Ψ + b
for velocity u , source term b and diffusion coefficient Γ . Integration of the PDE over a control volume and using Gauss divergence theorem yields:
A ( n ) . ρ u Ψ d A = A ( n ) . Γ Ψ d A + C V b d V .
After using suitable discretization schemes for convective and diffusion terms, the resulting algebraic equation at the node point p surrounded by neighboring relevant nodes (subscript n) is written as:
a p ϕ p = a n ϕ n + s .
A QUICK scheme is used to discretize the convective terms in the momentum and energy equations while a SIMPLE algorithm is used for velocity–pressure coupling. The resulting system of algebraic equations was solved using the Gauss–Siedel point-by-point iterative method and algebraic multigrid method. The normalized residual is calculated as:
R ϕ = a l l c e l l s | a p ϕ p - a n ϕ n - s | a l l c e l l s | a p ϕ p | .
When the residuals for all dependent variables become less than 10 - 5 , an iterative solution is stopped. Under-relaxation factors are used to enhance the converge speed of the solution and the under-relaxation parameters for u, v, and T are all set to 0.6, whereas the under-relaxation parameter for pressure correction is set to 0.32.

2.4. Grid Independence and Code Validation

The grid independent test for various numbers of elements was performed. High gradients in the boundary layers are resolved by using finer meshes near the walls.Thermal efficiency and PV efficiency for different number of elements are demonstrated in Table 4. G3 with 66,056 triangular elements are used in the subsequent computations. Validation of the present code is performed by using the numerical results of [30]. Forced convection in a cavity was considered at Reynolds number of 500. The comparison results for the local Nusselt number distribution along the walls of the cavity are shown in Figure 2.

3. Results and Discussion

Effects of nanoparticle addition to the water in the channel of a PV-thermal module on the thermal and PV-efficiency was numerically investigated. SiO 2 nanoparticles different shapes and solid particle volume fractions were used. Figure 3 shows the velocity and temperature distribution in the PV-module. In the channel, a laminar velocity profile is developed and its maximum value is seen in the mid of the channel which has a value of 0.025 m/s for the fixed value of (q = 1000 W /m 2 , h = 5 W /m 2 K, ϕ = 0 . 02 with cylindrical shape particles). For this flow velocity, Reynolds number remains less than 2100 in the channel. Thermal gradients are seen in the layers of the PV module, which is due to the different thicknesses and thermal conductivities of these layers.
Figure 4 shows the effects of nanoparticle volume fraction ( ϕ ) and particle type on the variation of thermal and total efficiency of the PV-thermal module. Both efficiencies enhance with higher ϕ values. Among different particle shapes, cylindrical ones perform best. Discrepancy between cylindrical shape and other shapes increases for higher particle volume fractions. Total efficiency increases by about 7.39% at the highest volume fraction ( ϕ = 0 . 05 ) with cylindrical shape particles. As compared to spherical shape particle, cylindrical ones gives 3.95% more enhancement in the total efficiency for the highest particle volume fraction.
As the inlet temperature of water-SiO 2 nanofluid increases, thermal and total efficiency deteriorate as shown in Figure 5. The rate of deterioration is higher for the thermal efficiency and up to 40% in the reduction of the efficiency is seen when nanofluid temperature is increased from 10 C to 50 C.
Figure 6 demonstrates the effects of solar irradiation and solid nanoparticles volume faction on the variation of efficiencies (h = 5 W /m 2 K, T i n = 30 C with cylindrical shape particles). Thermal efficiency increases with higher values of solar irradiation while the PV-efficiency decreases and higher efficiency values are achieved for higher ϕ values. Higher surface temperature is obtained for higher values of solar irradiation and PV-efficiency decreases, which are defined in Equation (5). Thermal efficiency increases by about 9.17% and 9.82% for water and for nanofluid with highest volume fraction. There is a negligible effect of the particle addition on the PV-efficiency enhancements.
Convective loss is characterized by the convective heat transfer coefficient dependent upon the wind speed v. As the value of heat transfer coefficient enhances, thermal efficiency decreases as it is shown in Figure 7 and Figure 8. However, PV-efficiency enhances with higher h values since the PV-layer surface temperature decreases, but the rate of enhancement is not significant.The discrepancy between thermal efficiency for heat transfer coefficient of h = 5 W /m 2 K and h = 10 W /m 2 K is 12.5% and 9.28% for water and for nanofluid with ϕ = 0 . 05 . Adding nanoparticle results in higher thermal efficiency enhancement for the highest value of heat transfer coefficient, which is 11.11% with the highest volume fraction of cylindrical particles.

3.1. Efficiency Correlation with Artificial Neural Networks

Artificial neural networks (ANN) or other practical prediction methods can be used to obtain the correlations for efficiencies of PV-thermal module or thermal engineering systems [31,32,33,34,35,36,37,38,39,40,41]. Radial basis function networks consist of three-layer network structures that include input, hidden and output layers. The hidden layer nodes are radial basis functions. The outputs are calculated by a weighted average sum of the radial basis functions, which can be given as [37]:
y ( x i ) = k = 1 N w k Ψ | | x i - d k | | + b .
Radial basis function response decreases monotonically from a center point with distance. Gaussian function is a radial basis function which has central point c and smoothness parameter σ which controls the shape of the function. It is given in the following form:
f ( x ) = e - ( x - c ) 2 / σ 2 .
A schematic representation of network topology is given in Figure 9 with three inputs: (solid particle volume fraction ( ϕ ), convective heat transfer coefficient (h) and solar irradiation (q)) and two outputs (thermal and PV-efficiency).
In order to evaluate the performance of trained networks, different error measures can be used. Mean square error (MSE) and coefficient of determination ( R 2 ) performance parameters can be given as:
MSE = 1 N k = 1 N ( y C F D - y k A N N ) 2 ,
R 2 = 1 - k = 1 N ( y k C F D - y k A N N ) 2 k = 1 N ( y k C F D - y ¯ ) 2 ,
where y k A N N , y k C F D , N and y ¯ represent the predicted value form ANN, CFD value, sample number and the mean value of CFD values, respectively.
The MATLAB Neural Network Toolbox (Version 2010, The Mathworks, Natick, USA) was used to select the number of hidden layers, number of neurons in each layer, training algorithm [42]. Feed-forward network structure with one hidden layer and a linear output layer was selected. The number of the neurons of ANN model was taken as 10. The feed-forward network structure with hidden layers and the linear output layer was selected and Levenberg–Marquardt back-propagation was used as the training algorithm. The random data division property of MATLAB is used and 70 % of the data was used for estimation while 15 % was used for validation and 15 % of the data was used for testing purposes. Table 5 shows the number of samples for training, validation and testing, mean squared error (MSE) values and regression R values. A higher R value denotes a higher correlation between the outputs and target values.
Table 6 represents the comparison results of CFD data between the predicted data by artificial neural networks for various values of pertinent parameters. The difference between the actual CFD data and established artificial neural network model is very small. This modeling strategy with ANN is useful for this system in order to obtain the performance predictions of a PV-thermal module in a fast and cheap way as compared to a high fidelity CFD computation, but it still requires some of the data from CFD computations for training.

4. Conclusions

In this study, a numerical simulation of a PV-thermal module with SiO 2 -water nanofluid was performed. It was observed that cylindrical shape particles give the best performance in terms of efficiency enhancement. Total PV/T module efficiency enhances by about 7.39% at the highest volume fraction with cylindrical shape particles. As compared to spherical ones, up to 4% more in the efficiency enhancement was observed with cylindrical shape particles. Thermal and total efficiency increase for higher solid particle volume fraction, higher values of solar irradiation, lower values of convective heat transfer coefficient and inlet temperature. Adding nanoparticles is advantageous for the case where convective heat transfer coefficient is high. Finally, correlation based on radial basis artificial neural networks was obtained for thermal and PV-efficiency of the PV-thermal module. The performance characteristics of solar PV-thermal module with ANN are compared with those obtained using the CFD modeling and have been to be in excellent agreement.

Author Contributions

F.S. performed the numerical simulations and wrote some sections of the manuscript. A.J.C. prepared some other sections of the paper and analyzed the results. All of the authors contributed equally for reviewing and revising the manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

bbias term
ccenter point
dparticle size
Gincident energy
hlocal heat transfer coefficient
kthermal conductivity
Mmolecular weight
NAvogadro number
nunit normal vector
ppressure
Rresidual
Ttemperature
u, vxy velocity components
wweight of neural network
x, yCartesian coordinates

Greek Characters

α thermal diffusivity
β thermal diffusivity
η efficient
θ non-dimensional temperature
μ dynamic viscosity
ρ density of the fluid
σ smoothing parameter
ϕ solid volume fraction
Ψ radial basis function

Subscripts

ccold
hhot
nfnanofluid
nneigbour
pvphoto-voltaic
refreference
ththermal

References

  1. Nielda, D.; Kuznetsov, A. Forced convection in a parallel-plate channel occupied by a nanofluid or a porous medium saturated by a nanofluid. Int. J. Heat Mass Transf. 2014, 70, 430–433. [Google Scholar] [CrossRef]
  2. Abu-Nada, E.; Chamkha, A.J. Mixed convection flow in a lid-driven inclined square enclosure filled with a nanofluid. Eur. J. Mech. B/Fluids 2010, 29, 472–482. [Google Scholar] [CrossRef]
  3. Chamkha, A.J.; Abu-Nada, E. Mixed convection flow in single- and double-lid driven square cavities filled with water-Al2O3 nanofluid: Effect of viscosity models. Eur. J. Mech. B/Fluids 2012, 36, 82–96. [Google Scholar] [CrossRef]
  4. Mahmoudi, A.H.; Pop, I.; Shahi, M. Effect of magnetic field on natural convection in a triangular enclosure filled with nanofluid. Int. J. Therm. Sci. 2012, 59, 126–140. [Google Scholar] [CrossRef]
  5. Oztop, H.F.; Abu-Nada, E. Numerical study of natural convection in partially heated rectangular enclosures filled with nanofluids. Int. J. Heat Fluid Flow 2008, 29, 1326–1336. [Google Scholar] [CrossRef]
  6. Selimefendigil, F.; Oztop, H.F. Pulsating nanofluids jet impingement cooling of a heated horizontal surface. Int. J. Heat Mass Transf. 2014, 69, 54–65. [Google Scholar] [CrossRef]
  7. Sheikholeslami, M.; Gorji-Bandpy, M.; Ganji, D.; Soleimani, S.; Seyyedi, S. Natural convection of nanofluids in an enclosure between a circular and a sinusoidal cylinder in the presence of magnetic field. Int. Commun. Heat Mass Transf. 2012, 39, 1435–1443. [Google Scholar] [CrossRef]
  8. Selimefendigil, F.; Oztop, H.F. Identification of forced convection in pulsating flow at a backward facing step with a stationary cylinder subjected to nanofluid. Int. Commun. Heat Mass Transf. 2013, 45, 111–121. [Google Scholar] [CrossRef]
  9. Sridhara, V.; Satapathy, L.N. Al2O3-based nanofluids: A review. Nanoscale Res. Lett. 2011, 6, 1–16. [Google Scholar] [CrossRef] [PubMed]
  10. Selimefendigil, F.; Oztop, H.F. Influence of inclination angle of magnetic field on mixed convection of nanofluid flow over a backward facing step and entropy generation. Adv. Powder Technol. 2015, 26, 1663–1675. [Google Scholar] [CrossRef]
  11. Gherasim, I.; Roy, G.; Nguyen, C.T.; Vo-Ngoc, D. Experimental investigation of nanofluids in confined laminar radial flows. Int. J. Therm. Sci. 2009, 48, 1486–1493. [Google Scholar] [CrossRef]
  12. Selimefendigil, F.; Oztop, H.F.; Abu-Hamdeh, N. Mixed convection due to rotating cylinder in an internally heated and flexible walled cavity filled with SiO2-water nanofluids: Effect of nanoparticle shape. Int. Commun. Heat Mass Transf. 2016, 71, 9–19. [Google Scholar] [CrossRef]
  13. Selimefendigil, F.; Oztop, H.F. Effects of Nanoparticle Shape on Slot-Jet Impingement Cooling of a Corrugated Surface With Nanofluids. J. Therm. Sci. Eng. Appl. 2017, 9, 021016. [Google Scholar] [CrossRef]
  14. Selimefendigil, F.; Oztop, H.F. Laminar Convective Nanofluid Flow Over a Backward-Facing Step With an Elastic Bottom Wall. J. Therm. Sci. Eng. Appl. 2018, 10, 041003. [Google Scholar] [CrossRef]
  15. Mahian, O.; Kianifar, A.; Kalogirou, S.A.; Pop, I.; Wongwises, S. A review of the applications of nanofluids in solar energy. Int. J. Heat Mass Transf. 2013, 57, 582–594. [Google Scholar] [CrossRef]
  16. Mahian, O.; Kianifar, A.; Sahin, A.Z.; Wongwises, S. Performance analysis of a minichannel-based solar collector using different nanofluids. Energy Convers. Manag. 2014, 88, 129–138. [Google Scholar] [CrossRef]
  17. Meibodi, S.S.; Kianifar, A.; Niazmand, H.; Mahian, O.; Wongwises, S. Experimental investigation on the thermal efficiency and performance characteristics of a flat plate solar collector using SiO2/EG-water nanofluids. Int. J. Heat Mass Transf. 2015, 65, 71–75. [Google Scholar] [CrossRef]
  18. Chen, M.; He, Y.; Huang, J.; Zhu, J. Investigation into Au nanofluids for solar photothermal conversion. Int. J. Heat Mass Transf. 2017, 108, 1894–1900. [Google Scholar] [CrossRef]
  19. Yan, S.; Wang, F.; Shi, Z.; Tian, R. Heat transfer property of SiO2/water nanofluid flow inside solar collector vacuum tubes. Appl. Therm. Eng. 2017, 118, 385–391. [Google Scholar] [CrossRef]
  20. Yazdanifard, F.; Ameri, M.; Ebrahimnia-Bajestan, E. Performance of nanofluid-based photovoltaic/thermal systems: A review. Renew. Sustain. Energy Rev. 2017, 76, 323–352. [Google Scholar] [CrossRef]
  21. Al-Waeli, A.H.; Sopian, K.; Chaichan, M.T.; Kazem, H.A.; Hasan, H.A.; Al-Shamania, A.N. An experimental investigation of SiC nanofluid as a base-fluid for a photovoltaic thermal PV/T system. Energy Convers. Manag. 2017, 142, 547–558. [Google Scholar] [CrossRef]
  22. Hassani, S.; Taylor, R.A.; Mekhilef, S.; Saidur, R. A cascade nanofluid-based PV/T system with optimized optical and thermal properties. Energy 2016, 112, 963–975. [Google Scholar] [CrossRef]
  23. Jing, D.; Hu, Y.; Liu, M.; Wei, J.; Guo, L. Preparation of highly dispersed nanofluid and CFD study of its utilization in a concentrating PV/T system. Sol. Energy 2015, 112, 30–40. [Google Scholar] [CrossRef]
  24. Vajjha, R.; Das, D. Experimental determination of thermal conductivity of three nanofluids and development of new correlations. Int. J. Heat Mass Transf. 2009, 52, 4675–4682. [Google Scholar] [CrossRef]
  25. Koo, J.; Kleinstreuer, C. Laminar nanofluid flow in microheat-sinks. Int. J. Heat Mass Transf. 2005, 48, 2652–2661. [Google Scholar] [CrossRef]
  26. Maxwell, J. A Treatise on Electricity and Magnetism; Oxford University Press: Oxford, UK, 1873. [Google Scholar]
  27. Corcione, M. Heat transfer features of buoyancy-driven nanofluids inside rectangular enclosures differentially heated at the sidewalls. Int. J. Therm. Sci. 2010, 49, 1536–1546. [Google Scholar] [CrossRef]
  28. Vanaki, S.M.; Mohammed, H.A.; Abdollahi, A.; Wahid, M.A. Effect of nanoparticle shapes on the heat transfer enhancement in a wavy channel with different phase shifts. J. Mol. Liquids 2014, 196, 32–42. [Google Scholar] [CrossRef]
  29. Timofeeva, E.; Routbort, J.; Singh, D. Particle shape effects on thermophysical properties of alumina nanofluids. J. Appl. Phys. 2009, 106, 014304. [Google Scholar] [CrossRef]
  30. Saeidi, S.; Khodadadi, J. Forced convection in a square cavity with inlet and outlet ports. Int. J. Heat Mass Transf. 2006, 49, 1896–1906. [Google Scholar] [CrossRef]
  31. Chine, W.; Mellit, A.; Lughi, V.; Malek, A.; Sulligoi, G.; Pavan, A.M. A novel fault diagnosis technique for photovoltaic systems based on artificial neural networks. Renew. Energy 2016, 90, 501–512. [Google Scholar] [CrossRef] [Green Version]
  32. Selimefendigil, F.; Bayrak, F.; Oztop, H.F. Experimental analysis and dynamic modeling of a photovoltaic module with porous fins. Renew. Energy 2018, 125, 193–205. [Google Scholar] [CrossRef]
  33. Selimefendigil, F.; Oztop, H.F. Numerical Study and POD-Based Prediction of Natural Convection in a Ferrofluids-Filled Triangular Cavity with Generalized Neural Networks. Numer. Heat Transf. Part A Appl. 2015, 67, 1136–1161. [Google Scholar] [CrossRef]
  34. Mellit, A.; Saglam, S.; Kalogirou, S. Artificial neural network-based model for estimating the produced power of a photovoltaic module. Renew. Energy 2013, 60, 71–78. [Google Scholar] [CrossRef]
  35. Huang, C.; Bensoussan, A.; Edesess, M.; Tsui, K.L. Improvement in artificial neural network-based estimation of grid connected photovoltaic power output. Renew. Energy 2016, 97, 838–848. [Google Scholar] [CrossRef]
  36. Selimefendigil, F.; Polifke, W. Nonlinear, Proper-Orthogonal-Decomposition-Based Model of Forced Convection Heat Transfer in Pulsating Flow. AIAA J. 2014, 52, 131–145. [Google Scholar] [CrossRef]
  37. Bonanno, F.; Capizzi, G.; Graditi, G.; Napoli, C.; Tina, G. A radial basis function neural network based approach for the electrical characteristics estimation of a photovoltaic module. Appl. Energy 2012, 97, 956–961. [Google Scholar] [CrossRef]
  38. Selimefendigil, F.; Oztop, H.F. A Fuzzy-Pod Based Estimation of Unsteady Mixed Convection in a Partition Located Cavity with Inlet and Outlet Ports. Int. J. Comput. Methods 2015, 12, 1350107. [Google Scholar] [CrossRef]
  39. Selimefendigil, F.; Oztop, H.F. Soft Computing Methods for Thermo-Acoustic Simulation. Numer. Heat Transf. Part A Appl. 2014, 66, 271–288. [Google Scholar] [CrossRef]
  40. Aminossadati, S.; Kargar, A.; Ghasemi, B. Adaptive network-based fuzzy inference system analysis of mixed convection in a two-sided lid-driven cavity filled with a nanofluid. Int. J. Therm. Sci. 2012, 52, 102–111. [Google Scholar] [CrossRef]
  41. Selimefendigil, F.; Oztop, H.F. POD-based reduced order model of a thermoacoustic heat engine. Eur. J. Mech. B/Fluids 2014, 48, 135–142. [Google Scholar] [CrossRef]
  42. Matlab: The Language of Technical Computing. The Math Works Inc.: Natick MA, USA, 2000.
Figure 1. Schematic representation of the layers in the PV-thermal module.
Figure 1. Schematic representation of the layers in the PV-thermal module.
Applsci 08 02223 g001
Figure 2. Code validation study.
Figure 2. Code validation study.
Applsci 08 02223 g002
Figure 3. Velocity field (a) and temperature (b) in the Photovoltaic-thermal module module, (q = 1000 W/m 2 , h = 5 W/m 2 K, ϕ = 0 . 02 , cylindrical shape).
Figure 3. Velocity field (a) and temperature (b) in the Photovoltaic-thermal module module, (q = 1000 W/m 2 , h = 5 W/m 2 K, ϕ = 0 . 02 , cylindrical shape).
Applsci 08 02223 g003
Figure 4. Effects of the particle shape and solid volume fraction on the variation of efficiencies (q = 1000 W/m 2 , h = 5 W/m 2 K, T i n = 30 C)
Figure 4. Effects of the particle shape and solid volume fraction on the variation of efficiencies (q = 1000 W/m 2 , h = 5 W/m 2 K, T i n = 30 C)
Applsci 08 02223 g004
Figure 5. Effects of the inlet temperature on the variation of efficiencies (q = 1000 W/m 2 , h = 5 W/m 2 K, ϕ = 0 . 02 , cylindrical shape).
Figure 5. Effects of the inlet temperature on the variation of efficiencies (q = 1000 W/m 2 , h = 5 W/m 2 K, ϕ = 0 . 02 , cylindrical shape).
Applsci 08 02223 g005aApplsci 08 02223 g005b
Figure 6. Effects of the solar radiation on the variation of efficiencies for various solid particle volume fraction (h = 5 W/m 2 K, T i n = 30 C, cylindrical shape ).
Figure 6. Effects of the solar radiation on the variation of efficiencies for various solid particle volume fraction (h = 5 W/m 2 K, T i n = 30 C, cylindrical shape ).
Applsci 08 02223 g006aApplsci 08 02223 g006b
Figure 7. Efficiency versus solid particle volume fraction for two values of external heat transfer coefficient (q = 1000 W/m 2 , T i n = 30 C, cylindrical shape).
Figure 7. Efficiency versus solid particle volume fraction for two values of external heat transfer coefficient (q = 1000 W/m 2 , T i n = 30 C, cylindrical shape).
Applsci 08 02223 g007
Figure 8. Efficiency versus external heat transfer coefficient for two values of nanoparticle volume concentration (q = 1000 W/m 2 , T i n = 30 C, cylindrical shape).
Figure 8. Efficiency versus external heat transfer coefficient for two values of nanoparticle volume concentration (q = 1000 W/m 2 , T i n = 30 C, cylindrical shape).
Applsci 08 02223 g008
Figure 9. Schematic representation of the layers in the PV-thermal module.
Figure 9. Schematic representation of the layers in the PV-thermal module.
Applsci 08 02223 g009
Table 1. Thermophysical properties of layers of the PV-thermal module.
Table 1. Thermophysical properties of layers of the PV-thermal module.
NameThickness (mm)Density (kg/m 3 )Thermal Conductivity (W/m K)Heat Capacity (J/kg K)
glass3.225150.98820
eva0.459600.312090
PV0.22330150712
tedlar0.3511620.231465
aluminum12700160900
Table 2. Thermophysical properties of base fluid and SiO 2 nanoparticle [28].
Table 2. Thermophysical properties of base fluid and SiO 2 nanoparticle [28].
PropertyWaterSiO 2
ρ ( kg / m 3 ) 998.22200
c p ( J / kg K ) 4812703
k ( W / mK ) 0.611.2
μ ( N s / m 2 ) 0.001003-
Table 3. Constant coefficients for the effect of nanoparticle shape to the thermal conductivity and viscosity of the nanofluid [28,29].
Table 3. Constant coefficients for the effect of nanoparticle shape to the thermal conductivity and viscosity of the nanofluid [28,29].
Nanoparticle TypeC k A 1 A 2
cylindrical3.9513.5904.4
bricks3.371.9471.4
blades2.7414.6123.3
Table 4. Grid independence test (q = 1000 W/m 2 , h = 5 W/m 2 K, ϕ = 0 . 05 , T i n = 30 C).
Table 4. Grid independence test (q = 1000 W/m 2 , h = 5 W/m 2 K, ϕ = 0 . 05 , T i n = 30 C).
Grid NameNumber of ElementsThermal Efficiency (%)PV Efficiency (%)
G110,81650.3212.52
G219,45748.2512.50
G366,05647.2012.49
G4144,93447.1312.49
Table 5. Number of samples, mean square error (MSE) and correlation coefficients in the artificial neural network (ANN) modeling.
Table 5. Number of samples, mean square error (MSE) and correlation coefficients in the artificial neural network (ANN) modeling.
Number of SamplesMSER
Training3783.89 × 10 - 6 0.99992
Validation814.60 × 10 - 6 0.99991
Testing813.53 × 10 - 6 0.99993
Table 6. Performance predictions of solar PV-thermal module with ANN.
Table 6. Performance predictions of solar PV-thermal module with ANN.
ϕ h (W/m 2 K)q (W/m 2 ) η thermal (CFD) η thermal (ANN) η PV (CFD) η PV (ANN)
0340041.71641.95312.60912.594
0380044.49744.43612.48512.444
03120045.42445.3112.36112.408
0470043.30543.28112.51912.507
04110044.49744.57612.39712.417
0560042.1841.97312.55312.557
05100043.66343.63612.43112.454
0650040.60440.39912.58612.593
0690042.95242.70812.46512.479
0740038.2438.2812.61912.63
0780041.71641.79712.49912.491
07120042.87542.96712.3812.417
0870040.52440.69612.53212.527
08110042.22242.14812.41412.427
0.015340042.4742.8512.61712.606
0.015380045.36545.38712.50312.478
0.0153120046.3346.29112.38912.379
0.015470044.12444.23512.53512.529
0.0154110045.62945.53212.42112.427
0.015560043.11342.92612.56612.568
0.0155100044.78644.60412.45412.46
0.015650041.69741.23512.59612.601
0.015690043.75743.67412.48512.477
0.015740038.60938.99512.62612.634
0.015780042.4742.63412.51612.513
0.0157120043.75743.79912.40612.424
0.015870041.36741.52612.54712.539
0.0158110043.17242.99112.43712.44
0.02360044.6244.9112.56512.555
0.023100046.40446.34412.45512.428
0.02450043.72743.39512.59512.589
0.02490045.61145.43812.48612.479
0.02540041.27341.26112.62512.623
0.02580044.6244.35612.51612.52
0.025120045.36345.51512.40812.421
0.02670043.34543.18512.54612.56
0.026110044.6244.64712.43812.434
0.02760041.64541.82912.57612.579
0.027100043.72743.76512.46912.456
0.02850040.15839.91412.60512.598
0.02890042.63742.82812.49912.493
0.025340044.03843.70512.62412.61
0.025380045.98146.23712.51612.501
0.0253120047.0647.14912.40912.386
0.025470045.14845.1112.54612.551
0.0254110046.15846.37512.4412.443
0.025560044.03843.80112.57512.583
0.0255100045.59345.51712.4712.464
0.025650042.48442.02112.60412.608
0.025690044.32644.52212.49912.495
0.025740040.15339.74312.63212.639
0.025780043.39143.49512.52812.526
0.0257120044.90244.64812.42512.435
0.025870042.18842.412.55712.542
0.0258110043.80343.82912.45412.458
0.035340045.28244.55712.62912.617
0.035380047.02347.13912.52812.527
0.0353120048.18448.13612.42712.414
0.035470045.77946.1112.55612.573
0.0354110047.49847.37112.45512.447
0.035560045.28244.7912.58312.592
0.0355100046.67546.53812.48412.479
0.035650043.19242.89812.6112.614
0.035690045.66945.52312.51212.514
0.035740040.05740.6212.63712.642
0.035780044.41144.55612.53912.532
0.0357120045.86245.68212.44112.452
0.035870042.79443.42412.56612.545
0.0358110044.96544.84512.46912.475
0.04360046.8446.83712.58212.58
0.043100048.17848.22912.48312.472
0.04450044.96645.20212.60912.608
0.04490047.28647.30512.51112.528
0.04540042.15642.87212.63612.641
0.04580046.17146.33512.53812.558
0.045120047.50947.5312.44112.434
0.04670044.73745.25412.56512.563
0.046110046.71846.67812.46912.467
0.04760044.16343.74112.59112.572
0.047100045.76945.7212.49612.501
0.04850041.75541.63812.61712.596
0.04890044.6144.8512.52312.524
0.045340046.02345.27212.63412.622
0.045380048.32448.0512.53712.549
0.0453120049.09249.22212.44112.43
0.045470047.33847.10212.56412.579
0.0454110048.53448.3812.46812.454
0.045560046.02345.74212.5912.595
0.0455100047.86447.52212.49512.499
0.045650044.18243.72912.61612.617
0.045690046.02346.57912.52112.526
0.045740041.42141.48512.64112.641
0.045780046.02345.64612.54812.536
0.0457120046.7946.78412.45512.466
0.045870044.70844.43612.57412.549
0.0458110046.02345.90812.48112.495
0.05360047.20347.6412.58912.58
0.053100049.30149.15712.49512.499
0.05450046.15445.93512.61412.613
0.05490047.78648.19312.52112.538
0.05540044.58143.55612.63912.647
0.05580047.20347.35112.54712.554
0.055120048.07848.49712.45412.449
0.05670046.45446.23912.57212.558
0.056110047.6847.66112.4812.488
0.05760045.45544.58712.59712.573
0.057100047.20346.74512.50612.518
0.05850041.95942.41812.62212.602
0.05890045.45545.93512.53112.531

Share and Cite

MDPI and ACS Style

Chamkha, A.J.; Selimefendigil, F. Numerical Analysis for Thermal Performance of a Photovoltaic Thermal Solar Collector with SiO2-Water Nanofluid. Appl. Sci. 2018, 8, 2223. https://doi.org/10.3390/app8112223

AMA Style

Chamkha AJ, Selimefendigil F. Numerical Analysis for Thermal Performance of a Photovoltaic Thermal Solar Collector with SiO2-Water Nanofluid. Applied Sciences. 2018; 8(11):2223. https://doi.org/10.3390/app8112223

Chicago/Turabian Style

Chamkha, Ali J., and Fatih Selimefendigil. 2018. "Numerical Analysis for Thermal Performance of a Photovoltaic Thermal Solar Collector with SiO2-Water Nanofluid" Applied Sciences 8, no. 11: 2223. https://doi.org/10.3390/app8112223

APA Style

Chamkha, A. J., & Selimefendigil, F. (2018). Numerical Analysis for Thermal Performance of a Photovoltaic Thermal Solar Collector with SiO2-Water Nanofluid. Applied Sciences, 8(11), 2223. https://doi.org/10.3390/app8112223

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop