Seismic Behavior and Shear Bearing Capacity of Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) Beam-Column Joints
Abstract
:1. Introduction
2. Test Program
2.1. Specimen Details
2.2. Materials
2.3. Test Setup and Loading Procedure
3. Results and Discussion
3.1. Cracking Patterns
3.2. Load Deflection Behavior of UHPFRC Joints
- (1)
- During the load control stage, little shear deformation occurred at the joint, and the slopes of the loading and unloading curves in the hysteresis loops were basically overlapping prior to joint cracking.
- (2)
- During the displacement control stage, in the 1Δy displacement stage, the shear deformation angle of the joint was very small, and strength degradation was not observed. During the 2Δy stage, the slope of the hysteresis loops began to decline; however, the decline rate was small. The maximum shear carrying capacities of eight specimens were reached in the first 2Δy cycle. During the second and third cycles of the 2Δy displacement, strength and stiffness degradation of specimens was observed.
- (3)
- The shear angles of specimens EJ-1 and EJ-4 were relatively small, which may be explained by the fact that more obvious beam failure was observed for specimens EJ-1 and EJ-4 than other joint specimens. For other specimens, the shear deformation angles of joints became evident in the first 3Δy cycle, but the shear strengths decreased only slightly. This indicates that the deformation and toughness of the UHPFRC beam-column joint were effective. As the cycle times increased, the shear deformation angles of the specimens continued to increase, and the strengths began to decrease until failure. Because of the steel fiber, the UHPFRC has a higher toughness than NC; the ultimate shear deformation angles of UHPFRC joint are considerably larger than that at peak shear load. The shear deformation angles ratio between ultimate state and peak shear load range from 1.45 to 8.56, and the average value is 5.79. This indicates that UHPFRC beam-column joints have good deformation capacity.
- (4)
- From the comparisons of specimens EJ-2 and EJ-4, and specimens EJ-3 and EJ-5 with same beam reinforcement load bearing capacity, it can be seen that the use of HRB600 grade high-strength steel bars with relatively high yield strain and low elastic modulus can improve ductility and strength degradation of UHPFRC joints.
4. Calculation Method of Shear Carrying Capacity of UHPFRC Beam-Column Joint
4.1. Shear Resistance Mechanism of UHPFRC Beam-Column Joint
4.2. Components of Shear Carrying Capacity
4.2.1. Shear Force Carried by UHPFRC in Joint Core
4.2.2. Shear Force Carried by Steel Fiber
4.2.3. Shear Force Carried by Stirrup in Joint Core
4.3. Verification of Proposed Calculation Formula for Shear Carrying Capacity
5. Conclusions
- (1)
- A reinforced UHPFRC beam-column joint has a higher initial cracking strength and shear carrying capacity. Furthermore, the integrity of UHPFRC joint specimens is superior to NC joints when they eventually fail.
- (2)
- A suitable configuration of the transverse closed stirrup can enhance the shear carrying capacity owing to restraining occurrences and development of cracks. The shear bearing capacity of exterior joints is smaller than that of interior joints with the same sectional area and reinforcement. The shear strengths of exterior joints are approximately 80~90% of those of interior joints.
- (3)
- The use of HRB600 grade high-strength steel bars with relatively high yield strain and low elastic modulus can improve the ductility and strength degradation of UHPFRC joints.
- (4)
- The shear resistance mechanism of the reinforced UHPFRC beam-column joint consists of the diagonal strut and truss mechanisms. Steel fibers, such as the dispersive reinforcement bars, constitute the horizontal and vertical ties in the truss mechanism.
- (5)
- Based on test results, a formula (Equation (14)) was proposed, which can predict the shear bearing capacity of reinforced UHPFRC and steel fiber high-strength concrete joints. In the formula, the contribution of steel fibers to shear carrying capacity of joints was determined based on the test bond strength between steel fibers and UHPFRC matrix.
Author Contributions
Funding
Conflicts of Interest
References
- Hanson, N.W.; Conner, H.W. Seismic resistance of reinforced concrete beam-column joints. J. Struct. Div. Am. Soc. Civ. Eng. 1967, 93, 533–559. [Google Scholar]
- Tang, J.; Hu, C.; Yang, K.; Yan, Y. Seismic behaviour and shear strength of framed joint using steel-fiber reinforced concrete. J. Strut. Eng. 1992, 118, 341–358. [Google Scholar]
- Ganesan, N.; Indira, P.V.; Sabeena, M.V. Behaviour of hybrid fibre reinforced concrete beam–column joints under reverse cyclic loads. Mater. Des. 2014, 54, 686–693. [Google Scholar] [CrossRef]
- Filiatrault, A.; Ladicani, K.; Massicotte, B. Seismic performance of code-designed fiber reinforced concrete joints. ACI Mater. J. 1994, 91, 564–571. [Google Scholar]
- Liang, X.W.; Wang, Y.J.; Tao, Y.; Deng, M.K. Seismic performance of fiber-reinforced concrete interior beam-column joints. Eng. Strut. 2016, 126, 432–445. [Google Scholar] [CrossRef]
- Paulay, T.; Priestley, M.J.N. Seismic Design of Reinforced Concrete and Masonry Buildings; Wiley: New York, NY, USA, 1992. [Google Scholar]
- Hwang, S.J.; Lee, H.J. Analytical model for predicting shear strengths of exterior reinforced concrete beam-column joints for seismic resistance. ACI Struct. J. 2000, 96, 846–857. [Google Scholar]
- Hwang, S.J.; Lee, H.J. Strength prediction for discontinuity regions by softened strut-and-tie model. J. Struct. Eng. 2002, 128, 1519–1526. [Google Scholar] [CrossRef]
- Attaalla, S.A. General analytical model for nominal shear stress of type 2 normal- and high-strength concrete beam-column joints. ACI Mater. J. 2004, 101, 65–75. [Google Scholar]
- Shayanfar, J.; Akbarzadeh Bengar, H.; Niroomandi, A. A proposed model for predicting nonlinear behavior of rc joints under seismic loads. Mater. Des. 2016, 95, 563–579. [Google Scholar] [CrossRef]
- Richard, P.; Cheyrezy, M. Reactive powder concretes with high ductility and 200–800 MPa compressive strength. ACI Spec. Publ. 1994, 114, 507–518. [Google Scholar]
- Al-Tikrite, A.; Hadi, M.N.S. Mechanical properties of reactive powder concrete containing industrial and waste steel fibres at different ratios under compression. Constr. Build. Mater. 2017, 154, 1024–1034. [Google Scholar] [CrossRef]
- Habel, K.; Viviani, M.; Denarié, E.; Brühwiler, E. Development of the mechanical properties of an ultra-high performance fiber reinforced concrete (UHPFRC). Cem. Concr. Res. 2006, 36, 1362–1370. [Google Scholar] [CrossRef]
- Yang, I.-H.; Joh, C.; Lee, J.W.; Kim, B.-S. Torsional behavior of ultra-high performance concrete squared beams. Eng. Struct. 2013, 56, 372–383. [Google Scholar] [CrossRef]
- Shi, C.; Long, M.; Cao, C.; Long, G.; Lei, M. Mechanical property test and analytical method for reactive powder concrete columns under eccentric compression. KSCE J. Civ. Eng. 2016, 21, 1307–1318. [Google Scholar] [CrossRef]
- JGJ 101-96. Specificating of Testing Methods for Earthquake Resistant Building; China Building Industry Press: Beijing, China, 1997. [Google Scholar]
- Dang, C.-T.; Dinh, N.-H. Experimental study on structural performance of RC exterior beam-column joints retrofitted by steel jacketing and haunch element under cyclic loading simulating earthquake excitation. Adv. Civ. Eng. 2017, 2017, 1–11. [Google Scholar] [CrossRef]
- Zhao, H.T. Crack resistance of reinforced concrete beam-column joints. J. Build. Struct. 1990, 11, 38–48. [Google Scholar]
- Said, S.H.; Razak, H.A. Structural behavior of RC engineered cementitious composite (ECC) exterior beam–column joints under reversed cyclic loading. Constr. Build. Mater. 2016, 107, 226–234. [Google Scholar] [CrossRef]
- GB 50011-2010. Code for Seismic Design of Buildings; China Building Industry Press: Beijing, China, 2010. [Google Scholar]
- Alaee, P.; Li, B. High-strength concrete interior beam-column joints with high-yield-strength steel reinforcements. J. Struct. Eng. 2017, 143. [Google Scholar] [CrossRef]
- Kim, J.; Lafave, J.M. Key influence parameters for the joint shear behavior of reinforced concrete (RC) beam–column connections. Steel Constr. 2007, 29, 2523–2539. [Google Scholar]
- Tran, M.T. Influence factors for the shear strength of exterior and interior reinforced concrete beam-column joints. Procedia Eng. 2016, 142, 63–70. [Google Scholar] [CrossRef]
- Fujii, S.; Morita, S. Comparison between interior and exterior RC beam-column joint behavior. In ACI SP 123-6: Design of Beam-Column Joints for Seismic Resistance; American Concrete Institute: Farmington Hills, MI, USA, 1991; pp. 155–165. [Google Scholar]
- Alaee, P.; Li, B. High-strength concrete exterior beam-column joints with high-yield strength steel reinforcements. Eng. Struct. 2017, 145, 305–321. [Google Scholar] [CrossRef]
- Hsu, T.T.C.; Belarbi, A. Compression response of cracked reinforced concrete. J. Struct. Eng. 1993, 119, 3590–3610. [Google Scholar]
- Zhang, L.-X.; Hsu, T.T.C. Behavior and analysis of 100 MPa concrete membrane elements. J. Struct. Eng. 1998, 124, 24–34. [Google Scholar] [CrossRef]
- Yong, Y. Damage Constitutive Model of RPC under Uniaxial Tension and Compression Based on Weibull Distribution; Northeast Dianli University: Jilin, China, 2015. [Google Scholar]
- Yan, S. The Research on the Tensile Performance of the Ultra-High-Performance Concrete Reinforced by Grading-Fiber; Hunan University: Changsha, China, 2006. [Google Scholar]
- Gao, D.; Shi, K. Calculation method for bearing capacity of steel fiber reinforced high-strength concrete beam-column joints. J. Build. Struct. 2014, 35, 71–79. [Google Scholar]
Specimen | Joint Type | UHPFRC Compressive Strength, MPa | Longitudinal Reinforcement in Beam | Longitudinal Reinforcement in Column | Stirrups in Joint Core | N/fc Aj | ||
---|---|---|---|---|---|---|---|---|
Top and Bottom Rebar | Type | Total Rebar | Type | |||||
EJ-1 | Exterior | 91.83 | 3-D14 | HRB400 | 4-D14 | HRB400 | 0 | 0.5 |
EJ-2 | Exterior | 103.95 | 2-D20+1-D10 | HRB400 | 4-D14 | HRB400 | 1-D6, 2 legs hoop | 0.3 |
EJ-3 | Exterior | 98.45 | 2-D20+1-D10 | HRB400 | 4-D14 | HRB400 | 1-D6, 2 legs hoop | 0.5 |
EJ-4 | Exterior | 89.85 | 3-D14 | HRB600 | 4-D14 | HRB600 | 0 | 0.3 |
EJ-5 | Exterior | 97.63 | 3-D14 | HRB600 | 4-D14 | HRB600 | 1-D6, 2 legs hoop | 0.3 |
J-1 | Interior | 112.3 | 3-D14 | HRB400 | 4-D14 | HRB400 | 0 | 0.3 |
J-2 | Interior | 104.1 | 3-D14 | HRB400 | 4-D14 | HRB400 | 0 | 0.5 |
J-3 | Interior | 105.8 | 3-D14 | HRB400 | 4-D14 | HRB400 | 1-D6, 2 legs hoop | 0.3 |
J-4 | Interior | 98.5 | 3-D14 | HRE400 | 4-D14 | HRE400 | 1-D6, 2 legs hoop | 0.5 |
Material | Cement | Silica Fume | 0.16~0.315 mm Quartz Sand | 0.315~0.63 mm Quartz Sand | 0.63~1.25 mm Quartz Sand | Steel Fiber | Super-Plasticizer | Water |
---|---|---|---|---|---|---|---|---|
Mass (kg) | 756.7 | 227.0 | 169.6 | 370.8 | 737.7 | 105.8 | 20.4 | 216.4 |
Type of Reinforcement | Application | Effective Diameter (mm) | Yield Strength (MPa) | Ultimate Strength (MPa) | Elastic Modulus (GPa) |
---|---|---|---|---|---|
HPB300 | Transverse stirrup | 6 | 353.56 | 398.30 | 210 |
HPB300 | Longitudinal bars | 9.5 | 360.6 | 522.2 | 201 |
HRB400 | Longitudinal bars | 14 | 423.40 | 632.40 | 200 |
HRB400 | Longitudinal bars | 20 | 441.90 | 588.60 | 200 |
HRB600 | Longitudinal bars | 14 | 651.00 | 861.67 | 195 |
Specimen | fcu/MPa | bc × hc/mm × mm | bb × hb/mm × mm | Volume Percentage of Fiber | Stirrup in Joint Core | fy/MPa | Design Axial Compression Load Level | Vjt/kN | Vjc/kN | Vjt/Vjc |
---|---|---|---|---|---|---|---|---|---|---|
EJ-1 | 91.83 | 200 × 200 | 150 × 250 | 1.3 | 0 | - | 0.5 | 216.9 | 290.1 | 0.748 |
EJ-2 | 103.95 | 200 × 200 | 150 × 250 | 1.3 | 1Φ6 | 353.6 | 0.3 | 271.2 | 276.9 | 0.979 |
EJ-3 | 93.45 | 200 × 200 | 150 × 250 | 1.3 | 1Φ6 | 353.6 | 0.5 | 302.6 | 302.8 | 0.999 |
EJ-4 | 89.85 | 200 × 200 | 150 × 250 | 1.3 | 0 | - | 0.3 | 232.9 | 258.6 | 0.901 |
EJ-5 | 97.63 | 200 × 200 | 150 × 250 | 1.3 | 1Φ6 | 353.6 | 0.3 | 312.6 | 273.3 | 1.144 |
J-1 | 112.3 | 200 × 200 | 150 × 250 | 1.3 | 0 | - | 0.3 | 374.8 | 339.2 | 1.105 |
J-2 | 104.1 | 200 × 200 | 150 × 250 | 1.3 | 0 | - | 0.5 | 410.2 | 368.5 | 1.113 |
J-3 | 105.8 | 200 × 200 | 150 × 250 | 1.3 | 1Φ6 | 353.6 | 0.3 | 380.9 | 347.4 | 1.096 |
J-4 | 98.5 | 200 × 200 | 150 × 250 | 1.3 | 1Φ6 | 353.6 | 0.5 | 379.2 | 378.5 | 1.002 |
JDZ0.3-0.5-0.6 | 82.1 | 200 × 200 | 150 × 250 | 0.5 | 2Φ8 | 307 | 0.3 | 328.1 | 335.2 | 0.979 |
JDZ0.2-1.0-0 | 79.1 | 200 × 200 | 150 × 250 | 1.0 | 0 | - | 0.2 | 330.9 | 302.3 | 1.095 |
JDZ0.3-1.0-0 | 81.7 | 200 × 200 | 150 × 250 | 1.0 | 0 | - | 0.3 | 348.4 | 332.1 | 1.049 |
JDZ0.4-1.0-0 | 78.1 | 200 × 200 | 150 × 250 | 1.0 | 0 | - | 0.4 | 360.5 | 352.1 | 1.024 |
© 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Wang, D.; Ju, Y.; Zheng, W.; Shen, H. Seismic Behavior and Shear Bearing Capacity of Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) Beam-Column Joints. Appl. Sci. 2018, 8, 810. https://doi.org/10.3390/app8050810
Wang D, Ju Y, Zheng W, Shen H. Seismic Behavior and Shear Bearing Capacity of Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) Beam-Column Joints. Applied Sciences. 2018; 8(5):810. https://doi.org/10.3390/app8050810
Chicago/Turabian StyleWang, Dehong, Yanzhong Ju, Wenzhong Zheng, and Hao Shen. 2018. "Seismic Behavior and Shear Bearing Capacity of Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) Beam-Column Joints" Applied Sciences 8, no. 5: 810. https://doi.org/10.3390/app8050810
APA StyleWang, D., Ju, Y., Zheng, W., & Shen, H. (2018). Seismic Behavior and Shear Bearing Capacity of Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) Beam-Column Joints. Applied Sciences, 8(5), 810. https://doi.org/10.3390/app8050810