Enhanced Coil Design for Inductive Power-Transfer-Based Power Supply in Medium-Voltage Direct Current Sensors

1
Department of Electrical Engineering, Chonnam National University, 77, Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea
2
Energy Convergence Research Center, Korea Electronics Technology Institute, 226, Cheomdangwagi-ro, Buk-gu, Gwangju 61011, Republic of Korea
*
Authors to whom correspondence should be addressed.
Electronics 2024, 13(17), 3573; https://doi.org/10.3390/electronics13173573
Submission received: 21 August 2024 / Revised: 6 September 2024 / Accepted: 6 September 2024 / Published: 9 September 2024
(This article belongs to the Special Issue New Horizons and Recent Advances of Power Electronics)

Abstract

:
This paper presents an integrated coil design method for inductive power-transfer (IPT) systems. Because a medium-voltage direct current (MVDC) distribution network transmits power at relatively high voltages (typically in the tens of kV), accurate fault diagnosis using high-performance sensors is crucial to improve the safety of MVDC distribution networks. With the increasing power consumption of high-performance sensors, conventional power supplies using optical converters with 5 W-class output characteristics face limitations in achieving the rated output power. Therefore, this paper proposes a safe and reliable power supply method using the principle of IPT to securely maintain the insulation distance between the distribution network and the current sensor-supply line. A 100 W prototype IPT system is investigated, and its feasibility is validated by comparing its performance with conventional optical converters.

1. Introduction

Medium-voltage direct current (MVDC) distribution networks are quickly evolving into complex systems where various DC power sources and loads are interconnected. This evolution is crucial for enhancing the efficiency and reliability of modern power systems. MVDC distribution networks are particularly important in applications such as those in marine, military, and industrial settings due to their high power density and low power loss advantages [1]. Consequently, there is a critical need to improve the stability and reliability of MVDC distribution networks. As the power sources and loads interconnected with the MVDC grid increase, the frequent fluctuations and the risk of faults also increase, which impacts the stability of the MVDC distribution network significantly [2]. Currently, several ongoing studies are focusing on fault diagnosis and protection algorithms for various converters associated with the MVDC network [3,4,5]. The existence of these studies confirms the critical importance of high-performance sensors, as reliable fault diagnosis and protection algorithms depend heavily on the accurate and timely detection provided by such sensors. The digital merging unit system described in Figure 1 incorporates an integrated network of sensors and auxiliary electronic circuits. To ensure high reliability, Hall-effect current sensors are employed, securing high-voltage insulation between the MVDC distribution network and the digital merging unit system.
In general, in peripheral interconnected circuits such as MVDC and voltage sensors, along with optical components such as optical converters, optical fibers and resonant beams are used as auxiliary power sources to meet high-voltage insulation requirements [6,7,8]. Ref. [6] proposed using optical converters for powering IoT sensors, while [7] and [8] suggested a method of transmitting both power and data together via optical converters. However, currently, commercialized optical converters typically offer only low-rated output and efficiency. Table 1 shows the specifications of commonly used optical converters. They deliver an output of approximately 5 W with low efficiency (26%). Additionally, in the case of optical fiber cables, exposure to external environmental conditions can lead to performance degradation as the cables age. Table 2 shows the electrical specifications of the MVDC sensor. The sensor currently consumes 44 W of power; however, due to potential performance improvements and an increase in the number of sensors, the total power consumption could rise to 100 W. As the power demand increases and the rated voltage rises from 5 V to 24 V, significant limitations often arise in terms of supplying power through optical conversion methods. Therefore, a 100 W auxiliary power system, which meets the high-performance sensor specifications and satisfies high-voltage insulation standards, would be highly desirable.
In this paper, an inductive power transfer (IPT) system with a compact design is proposed to solve these challenges. The IPT system ensures effective voltage insulation between power sources and load sensors. Constructing the IPT to supply constant power during sensor operation involves integrating it into a digital merging unit while maintaining a compact design with a fixed vertical separation distance of 100 mm. Various pad designs are proposed and compared to achieve high power density. Based on realistically achievable mutual inductance (M) ranges from the designed (coil) pad, a compensation topology that meets the requirements is determined. Furthermore, by applying an integrated coil structure with optimal efficiency and high-power density considering the rated input and output characteristics, the IPT system is experimentally verified to have an efficiency of 69.5% and a rated power of 100 W. Finally, the proposed IPT system is compared with conventional optical converters to validate the feasibility of implementing it.
The structure of this paper is as follows: Section 2 contains the design and implementation of the proposed IPT system. Section 4 presents the experimental results and analysis, and Section 5 discusses the conclusions of this study and directions for future research.

2. Basic Analysis of Wireless Power Transfer

2.1. Basic Analysis of the IPT System

Figure 2 shows a schematic of an IPT converter. The entire system consists of an inverter that converts DC to AC power, a primary/secondary wireless pad that transmits power via electromagnetic induction, a primary/secondary resonant network that compensates for pad reactance for high-frequency operation, and a rectifier that converts AC power to DC. A typical IPT converter generates an AC voltage at the operating frequency required by the IPT system through either a half-bridge consisting of two MOSFETs or a full-bridge inverter consisting of four MOSFETs. The input AC voltage is a square wave with a fixed duty cycle of 0.5. This square wave includes various harmonics in the fundamental switching frequency waveform. However, since the passive components that make up the IPT converter act as filters, only the fundamental frequency component is transferred to the secondary side, and harmonics are assumed to be zero. Therefore, the output voltage waveform of the inverter can be approximated by Equation (1), including only the fundamental component. For a half-bridge inverter, n = 1 is used, whereas n = 2 is used for a full-bridge inverter.
u i n = 2 n U D C π 2 ( n = 1 , 2 )
The output AC waveform from the inverter induces a magnetic field through the time-varying current in the primary pad. The red dot in Figure 2 indicates the polarity. This magnetic flux is coupled to the secondary pad, inducing an electromotive force (EMF) and causing current to flow. The mutual inductance (M) between the primary pad current (ip) and secondary pad current (is) in loosely coupled transformer (LCT) is determined by their mutual magnetic interaction, where k is the coupling coefficient representing the efficiency of magnetic coupling between the primary and secondary pads. M is a crucial factor that determines the output characteristics and is given by the following equation:
M = k L p L s
The EMF induced on the secondary side passes through a resonant network, which reduces harmonics and is then rectified and smoothed into direct current (DC) by the rectifier. The output characteristics vary depending on the structure of the rectifier. Hence, the output DC characteristics can be calculated as shown in Equation (3), where a half-bridge rectifier is represented by m = 1, and a full-bridge rectifier is represented by m = 2. UL is DC load voltage, and IL is DC load current.
U L = π 2 2 m U o , a c , I L = m π 4 2 i o , a c ( m = 1 , 2 )

2.2. Wireless Pad Design

The value of k between the primary and secondary pad affects M. Therefore, it is important to minimize the variation in k due to fluctuations in separation distance when designing a wireless pad.
Figure 3 shows a 3D configuration of the integrated sensor. Given that the MVDC voltage applied to the power distribution line can reach 100 kV, it is crucial to ensure an adequate (and constant) air insulation distance. According to [9], a minimum separation distance of 3 kV/mm must be maintained for sufficient air insulation. In this paper, considering a feasible placement location and separation distance for the primary pad, a vertical separation distance of 100 mm is selected.
The wireless pad can utilize several different IPT 3-D pad designs, as shown in Table 3. The pads are classified into unipolar and multipolar pads based on the structure that radiates magnetic flux. Table 4 shows the FEM simulated k values for each pad design. Note that when the polarities are different, the magnetic flux of the pads cancels out, and no power is transmitted. Therefore, simulations for pads with different polarities are not conducted. The simulation results show that the RP-RP design, which has the largest outer diameter within the limited pad area, features the highest k (0.0280). Therefore, the basic design for the wireless pad in this paper is set to RP-RP.
After selecting the wireless pad design, the number of turns and the placement of the magnetic material are determined. The number of turns is selected considering the allowable area of the pad, the inner diameter affecting the k, and current stress. The diameter of the pad winding is set to 1.5 mm due to Lp and k. The current stress is designed to be less than 10 Arms, considering the AWG gauge. The number of winding layers can be as high as six, considering the maximum height of the pad. As the number of turns increases, M increases, which reduces the current required to link the same magnetic flux. However, because the coil winding resistance increases, an appropriate number of turns should be selected considering the losses. Table 4 shows the magnetic characteristics depending on the number of winding layers of the transmitting pad. The number of turns per layer is fixed at 10, taking into account the inner diameter, and a ferrite magnetic material is added to the center of the pad to increase the coupling coefficient. The receiving pad is fixed at 13 turns in one layer due to the volume limitation of the receiving part. Table 4 shows that as the number of winding layers increases, the inductance and coupling coefficient increase. Figure 4 shows the inductance and winding resistance graph depending on the number of winding layers of the transmitting pad. Through Table 5 and Figure 4, it can be seen that a mutual inductance of up to 3.369 μH can be achieved (designed), and considering the losses due to winding resistance, it is designed for four layers.

2.3. Selection of the Resonant Networks

When AC flows through the wireless pad, reactance components that impede the current flow are generated. These reactance components increase any reactive current within the IPT system, which leads to higher losses. Therefore, a resonant network is required to compensate for these reactance components. The resonant network can be configured either by connecting capacitors to compensate for the inductance of the primary and secondary pads or by adding more than two resonant elements to obtain a higher-order network [10]. Commonly used resonant networks are S-S, LCC-S, and DS-LCC topologies [11,12,13].
The design range of M capable of rated power transmission in the IPT system varies depending on the resonant network configuration. Figure 5 shows the achievable range of M for the S-S, LCC-S, and DS-LCC topologies. The inverter is assumed to operate at a fixed duty cycle of 0.5 and a fixed operating frequency of 100 kHz. For the S-S topology, the output characteristics are determined by uin, M, and f, which leads to a highly restricted designable M range. Conversely, the LCC-S and DS-LCC topologies have their output characteristics determined by primary or secondary LC resonant tanks. Moreover, the current flowing through the primary pad is determined by the primary LC resonant tank, while the output-side current is determined by the secondary LC tank. Consequently, as higher-order networks are configured, the range of designable M that can meet the rating is increased.
Figure 5 shows that the designable minimum M for the S-S topology is 9.46 μH, which indicates it is not suitable for the system developed in this study. For the LCC-S and DS-LCC topologies, provided the resonant inductor does not exceed the pad inductor in size, the achievable ranges for designable M are up to 61.9 μH and 458.9 μH, respectively. This demonstrates the feasibility of the targeted system design in this study. Although the DS-LCC topology has the advantage of optimizing losses generated in the pad, it also has the disadvantage of increased losses and reduced power density due to the higher number of passive components. Considering the limited volume of the secondary system designed in this paper, the LCC-S resonant network is selected.
The LCC-S topology consists of a resonant network with one resonant inductor (Lin) and two resonant capacitors (Cp, Cf) on the primary side and one series resonant capacitor (Cs) on the secondary side. Kirchhoff’s current law for the IPT converter leads to the following equation [14]:
u in 0 0 = j ω L in 1 j ω C p 0 1 j ω C p 1 j ω C f + j ω L p j ω M 0 j ω M j ω L s + 1 j ω C s + R o , a c i in i p i s
Through Equation (4), it can be confirmed that the LCC-S topology exhibits constant current characteristics on the primary pad and constant voltage characteristics at the output. The resonant condition for the LCC-S topology can be formulated as follows:
ω = 1 L i n C p = 1 L p L i n C f = 1 L s C s .

2.4. Selection of the Inverter/Rectifier Structure

When designing a resonant network, it is critical to consider the AC input and output characteristics. Selecting the appropriate inverter and rectifier structures is important, as the output transformation of the IPT converter depends on these properties. Converting the input DC to AC through an inverter or transforming the AC output to DC through a rectifier can significantly alter the gain characteristics. These changes in gain characteristics directly impact the passive components of the resonant network within the IPT system.
In other words, selecting the inverter and rectifier structures is a fundamental step in the design process of the resonant network. Different structures provide different electrical characteristics and efficiencies, which affect the overall performance of the IPT converter. Moreover, the passive elements of the resonant network must be adjusted to match the specific gain characteristics introduced by these components. Hence, determining the optimal inverter and rectifier configuration is key to ensuring that the IPT converter operates efficiently and meets the desired specifications.
For the LCC-S topology, the impact of the inverter’s output gain is minimized because the primary LC resonant filter performs a V-C conversion, thus having little effect on the output characteristics. Given that fewer MOSFET switches in the inverter are advantageous in terms of cost and power density, a half-bridge inverter structure is selected for this study.
Conversely, the rectifier structure directly alters the electrical characteristics as it is connected in series with the secondary pad. When the rectifier is configured as a half-bridge, it operates as a voltage doubler, which increases the current flowing through the secondary pad while it decreases the current in the primary pad. In addition, because the primary pad resistance exceeds the secondary pad resistance, selecting a half-bridge rectifier structure helps improve efficiency and increase power density. Therefore, both the inverter and rectifier structures are chosen as half-bridge configurations. Figure 6 shows the IPT system composed of a half-bridge inverter, LCC-S topology, and half-bridge rectifier structure based on Section 2.3 and Section 2.4.

2.5. Integrated Inductor Design

The Lin included in the LCC-S topology can be integrated into the primary pad using an integrated coil structure, which reduces both volume and cost [15]. Figure 7 shows the AC equivalent circuit of the LCC-S topology with the integrated coil. In addition to the primary and secondary pads shown in Figure 2, the flux linkage generated in the resonant inductor can also affect the primary and secondary pads. If there is a k between the Lin and the pads, it can impact both the output characteristics and resonant conditions. Therefore, designing the system to decouple the integrated coil from the pads can be considered. To enable complete decoupling, the coil structure can be configured to cancel out the magnetic flux. Figure 8 shows a structure where Lp and Lin are perpendicular, resulting in canceled total magnetic flux.
The FEM simulation results in Figure 8 show that Minp, the mutual inductance between Lin and Lp, and Mins, the mutual inductance between Lin and Ls, are nearly zero, indicating that the mutual inductance can be neglected. Based on the pad characteristics in Figure 8, the system specifications are configured as shown in Table 5. Figure 9 shows the PSIM simulation results when applying the pad from Figure 8 and the system specifications from Table 5. Figure 9 confirms that the proposed system configuration achieves zero voltage switching (ZVS) and rated output characteristics.
Figure 10 shows the FEM simulation results when applying the system specifications from Table 6. The maximum flux density is 94.7 mT, which suggests that the magnetic material of the primary pad with the integrated coil structure does not saturate.

3. Experimental Verification

In this section, based on the analysis in Section 2, the IPT system prototype is designed. After the IPT system had been built, the output characteristics were verified through experiments.

3.1. System Configuration

Based on simulation results, a prototype pad was fabricated for experimental validation, as shown in Figure 11. The pad in Figure 12 was used to derive the pad inductance and coupling coefficients for the experimental prototypes, as depicted in Figure 13. The IPT system parameters are listed in Table 7.

3.2. Experimental Results

Figure 13 illustrates the experimental results of the IPT system. The output characteristics meet 100 W and 24 V, achieving an efficiency of 69.8%. Figure 14 shows the experimental waveforms, confirming the operation of ZVS.

4. Discussion

Table 8 compares conventional optical converters with the auxiliary power supply proposed in this paper using the IPT system. Table 5 confirms that the IPT-based power supply has higher efficiency and power density than conventional optical converters and ensures high-voltage isolation. Therefore, the application of the proposed IPT-based auxiliary power supply is considered feasible.

5. Conclusions

This paper proposed and investigated an integrated sensor power supply method for IPT systems that ensures high-voltage insulation and reliability. This IPT system overcomes the limitations of conventional optical converters with respect to voltage insulation. Various pad designs were compared to achieve the maximum k within a limited volume. In addition, the study analyzed the range of compensating topologies applicable to different M configurations on the pad. In order to achieve high power density, a resonant inductor forming an LCC-S topology was integrated into the primary pad, which minimized pad stress through a half-bridge inverter and rectifier structure. The experimental results confirmed an output power of 100 W with an efficiency of 69.8%. A comparison with conventional optical converters demonstrated both superior efficiency and power density. The proposed IPT-based auxiliary power configuration was shown to be well suited to meet the power requirements of various integrated sensors in future MVDC distribution networks.

Author Contributions

Conceptualization, S.J., J.-H.A. and D.-H.K.; methodology, S.J.; validation, S.J.; formal analysis, S.J.; investigation, S.J.; writing—original draft preparation, S.J.; writing—review and editing, J.-H.A. and D.-H.K. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant, funded by the Korean government (MOTIE) (20225500000120).

Data Availability Statement

The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding author/s.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Coffey, S.; Timmers, V.; Li, R.; Wu, G.; Egea-Àlvarez, A. Review of MVDC Applications, Technologies, and Future Prospects. Energies 2021, 14, 8294. [Google Scholar] [CrossRef]
  2. Kroposki, B.; Johnson, B.; Zhang, Y.; Gevorgian, V.; Denholm, P.; Hodge, B.-M.; Hannegan, B. Achieving a 100% Renewable Grid: Operating Electric Power Systems with Extremely High Levels of Variable Renewable Energy. IEEE Power Energy Mag. 2017, 15, 61–73. [Google Scholar] [CrossRef]
  3. Choi, U.-M.; Lee, J.-S.; Blaabjerg, F.; Lee, K.-B. Open-Circuit Fault Diagnosis and Fault-Tolerant Control for a Grid-Connected NPC Inverter. IEEE Trans. Power Electron. 2016, 31, 7234–7247. [Google Scholar] [CrossRef]
  4. Xiang, W.; Yang, S.; Adam, G.P.; Zhang, H.; Zuo, W.; Wen, J. DC Fault Protection Algorithms of MMC-HVDC Grids: Fault Analysis, Methodologies, Experimental Validations, and Future Trends. IEEE Trans. Power Electron. 2021, 36, 11245–11264. [Google Scholar] [CrossRef]
  5. Xiao, Q.; Jin, Y.; Jia, H.; Tang, Y.; Cupertino, A.F.; Mu, Y.; Teodorescu, R.; Blaabjerg, F.; Pou, J. Review of Fault Diagnosis and Fault-Tolerant Control Methods of the Modular Multilevel Converter Under Submodule Failure. IEEE Trans. Power Electron. 2023, 38, 12059–12077. [Google Scholar] [CrossRef]
  6. Zhang, Q.; Fang, W.; Liu, Q.; Wu, J.; Xia, P.; Yang, L. Distributed Laser Charging: A Wireless Power Transfer Approach. IEEE Internet Things J. 2018, 5, 3853–3864. [Google Scholar] [CrossRef]
  7. Helmers, H.; Armbruster, C.; von Ravenstein, M.; Derix, D.; Schoner, C. 6-W Optical Power Link with Integrated Optical Data Transmission. IEEE Trans. Power Electron. 2020, 35, 7904–7909. [Google Scholar] [CrossRef]
  8. Matsuura, M.; Nomoto, H.; Mamiya, H.; Higuchi, T.; Masson, D.; Fafard, S. Over 40-W Electric Power and Optical Data Transmission Using an Optical Fiber. IEEE Trans. Power Electron. 2021, 36, 4532–4539. [Google Scholar] [CrossRef]
  9. IEEE Std 1427-2020 (Revision of IEEE Std 1427-2006); IEEE Guide for Recommended Electrical Clearances and Insulation Levels in Air Insulated Electrical Power Substations. IEEE: Piscataway, NJ, USA, 2021; pp. 1–51.
  10. Shevchenko, V.; Husev, O.; Strzelecki, R.; Pakhaliuk, B.; Poliakov, N.; Strzelecka, N. Compensation Topologies in IPT Systems: Standards, Requirements, Classification, Analysis, Comparison and Application. IEEE Access 2019, 7, 120559–120580. [Google Scholar] [CrossRef]
  11. Li, W.; Zhao, H.; Deng, J.; Li, S.; Mi, C.C. Comparison Study on SS and Double-Sided LCC Compensation Topologies for EV/PHEV Wireless Chargers. IEEE Trans. Veh. Technol. 2016, 65, 4429–4439. [Google Scholar] [CrossRef]
  12. Chen, Y.; Zhang, H.; Shin, C.-S.; Jo, C.-H.; Park, S.-J.; Kim, D.-H. An Efficiency Optimization-Based Asymmetric Tuning Method of Double-Sided LCC Compensated WPT System for Electric Vehicles. IEEE Trans. Power Electron. 2020, 35, 11475–11487. [Google Scholar] [CrossRef]
  13. Yan, Z.; Zhang, Y.; Zhang, K.; Song, B.; Li, S.; Kan, T.; Mi, C.C. Fault-Tolerant Wireless Power Transfer System with a Dual-Coupled LCC-S Topology. IEEE Trans. Veh. Technol. 2019, 68, 11838–11846. [Google Scholar] [CrossRef]
  14. Jo, S.; Li, G.; Kim, D.-H.; Ahn, J.-H. Design of Power Supply Based on Inductive Power Transfer System for Medium Voltage Direct Current Sensor. Electronics 2023, 12, 4702. [Google Scholar] [CrossRef]
  15. Xie, J.; Li, G.; Jo, S.; Kim, D.-H. A Study on a Fully Integrated Coil Based on the LCCL-S Compensation Topology for Wireless EVs Charging Systems. Appl. Sci. 2023, 13, 9672. [Google Scholar] [CrossRef]
Figure 1. Schematic diagram of a digital merging unit system for an MVDC sensor.
Figure 1. Schematic diagram of a digital merging unit system for an MVDC sensor.
Electronics 13 03573 g001
Figure 2. Schematic of the IPT system.
Figure 2. Schematic of the IPT system.
Electronics 13 03573 g002
Figure 3. Schematic of an integrated MVDC sensor with critical dimensions.
Figure 3. Schematic of an integrated MVDC sensor with critical dimensions.
Electronics 13 03573 g003
Figure 4. Inductance and resistance vs. number of layers in the primary coil.
Figure 4. Inductance and resistance vs. number of layers in the primary coil.
Electronics 13 03573 g004
Figure 5. Range of achievable M for the output characteristics according to the resonant network at f = 100 kHz.
Figure 5. Range of achievable M for the output characteristics according to the resonant network at f = 100 kHz.
Electronics 13 03573 g005
Figure 6. Circuit diagram of the IPT system with LCC-S Topology.
Figure 6. Circuit diagram of the IPT system with LCC-S Topology.
Electronics 13 03573 g006
Figure 7. AC equivalent circuit with an integrated coil.
Figure 7. AC equivalent circuit with an integrated coil.
Electronics 13 03573 g007
Figure 8. Schematic of the LCC-S topology with integrated coil.
Figure 8. Schematic of the LCC-S topology with integrated coil.
Electronics 13 03573 g008
Figure 9. PSIM simulation result.
Figure 9. PSIM simulation result.
Electronics 13 03573 g009
Figure 10. Result of the FEM simulation.
Figure 10. Result of the FEM simulation.
Electronics 13 03573 g010
Figure 11. Wireless pad prototype with integrated coil.
Figure 11. Wireless pad prototype with integrated coil.
Electronics 13 03573 g011
Figure 12. Experimental prototype.
Figure 12. Experimental prototype.
Electronics 13 03573 g012
Figure 13. Experimental results.
Figure 13. Experimental results.
Electronics 13 03573 g013
Figure 14. Experimental waveforms.
Figure 14. Experimental waveforms.
Electronics 13 03573 g014
Table 1. Electrical specifications of an optical converter (YCH-H003).
Table 1. Electrical specifications of an optical converter (YCH-H003).
FigureParameterValue [Unit]
Electronics 13 03573 i001Input Power20 [W]
Output Power5.21 [W]
Vmax17.4 [V]
Imax300 [mA]
Efficiency26.0 [%]
Table 2. Electrical specifications of MVDC sensor.
Table 2. Electrical specifications of MVDC sensor.
FigureParameterValue [Unit]
Electronics 13 03573 i002Rated supply voltage24 [V]
Power consumption44 [W]
Primary voltage, measuring range63 [kV]
Primary current, measuring range3000 [A]
Frequency bandwidth50 [kHz]
Table 3. Various IPT 3-D pad designs.
Table 3. Various IPT 3-D pad designs.
Unipolar PadMultipolar Pad
Electronics 13 03573 i003
Circular Pad
Electronics 13 03573 i004
Electronics 13 03573 i005
Double D Pad (DDP)
Electronics 13 03573 i006
Bipolar Pad (BPP)
Electronics 13 03573 i007
Rectangular Pad
Electronics 13 03573 i008
Solenoid Pad
Electronics 13 03573 i009
Double D Quadrature
Pad (DDQP)
Electronics 13 03573 i010
Tripolar Pad (TPP)
Table 4. Results of various IPT 3-D pad coupling coefficients.
Table 4. Results of various IPT 3-D pad coupling coefficients.
PrimarySecondarykPrimarySecondaryk
Circular PadRectangular
Pad
0.0251Bipolar PadDouble D Pad0.0139
C Core PadRectangular
Pad
0.0278Double D Quadrature PadDouble D Pad0.0135
Solenoid PadRectangular
Pad
0.0137Double D PadBipolar Pad0.0129
Rectangular
Pad
Rectangular
Pad
0.0280Bipolar PadBipolar0.0127
Double D PadDouble D Pad0.0127
Table 5. Magnetic properties for different primary pad winding layers.
Table 5. Magnetic properties for different primary pad winding layers.
Tx Layer:1 Layer2 Layers4 Layers6 Layers
Lp [μH]8.48237.23135.35303.36
Ls [μH]29.79230.11530.11030.034
k0.0280.0330.0340.035
M [μH]0.4431.0032.1453.369
Table 6. Simulation specifications based on the FEM simulation.
Table 6. Simulation specifications based on the FEM simulation.
SymbolsParametersValue [Unit]
UDCDC input voltage110 [V]
fSwitching frequency100 [kHz]
LpPrimary pad self-inductance140.03 [μH]
LsSecondary pad self-inductance35.93 [μH]
LinResonant inductor8.39 [μH]
CpPrimary parallel-connected capacitor315.00 [nF]
CfPrimary series-connected capacitor19.52 [nF]
CsSecondary series-connected capacitor70.49 [nF]
Table 7. Specifications of the prototype.
Table 7. Specifications of the prototype.
SymbolsParametersValue [Unit]
UDCDC input voltage110 [V]
fSwitching frequency100 [kHz]
LpPrimary pad self-inductance148.83 [μH]
LsSecondary pad self-inductance31.73 [μH]
LinResonant inductor8.01 [μH]
CpPrimary parallel-connected capacitor311.30 [nF]
CfPrimary series-connected capacitor18.09 [nF]
CsSecondary series-connected capacitor79.83 [nF]
Table 8. Comparison between the optical converter and the IPT system.
Table 8. Comparison between the optical converter and the IPT system.
Parameters[6][7]Table 1Proposed IPT Converter
Electrical
Isolation
IsolatedIsolatedIsolatedIsolated
Rated Power5.5 W43.7 W5.21 W100 W
Output
Voltage
3.3 V/5 V6 V17.4 V24.7 V
Efficiency51%55%26.0%69.8%
FeasibilityXXXO
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Jo, S.; Kim, D.-H.; Ahn, J.-H. Enhanced Coil Design for Inductive Power-Transfer-Based Power Supply in Medium-Voltage Direct Current Sensors. Electronics 2024, 13, 3573. https://doi.org/10.3390/electronics13173573

AMA Style

Jo S, Kim D-H, Ahn J-H. Enhanced Coil Design for Inductive Power-Transfer-Based Power Supply in Medium-Voltage Direct Current Sensors. Electronics. 2024; 13(17):3573. https://doi.org/10.3390/electronics13173573

Chicago/Turabian Style

Jo, Seungjin, Dong-Hee Kim, and Jung-Hoon Ahn. 2024. "Enhanced Coil Design for Inductive Power-Transfer-Based Power Supply in Medium-Voltage Direct Current Sensors" Electronics 13, no. 17: 3573. https://doi.org/10.3390/electronics13173573

APA Style

Jo, S., Kim, D. -H., & Ahn, J. -H. (2024). Enhanced Coil Design for Inductive Power-Transfer-Based Power Supply in Medium-Voltage Direct Current Sensors. Electronics, 13(17), 3573. https://doi.org/10.3390/electronics13173573

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop