Of course, the work at Bochum was not singular in Europe, where accelerator-based atomic physics was pursued in many laboratories (to name a few: Aarhus, Berlin, Bielefeld, Caen, Copenhagen, Darmstadt, Kaiserslautern, Liège, Lund, Lyon, Munich, Oxford, Stockholm, and Uppsala, plus numerous US American and Canadian laboratories). It just happened that, at Bochum, the accelerator type (selected by researchers from three universities for certain nuclear physics experiments) and ion source capabilities turned out to be eminently suitable for atomic physics studies of many elements in the first third of the table of the elements. Because of the versatility of the facility, those elements could also be studied that found less interest or encountered too much experimental difficulty elsewhere.
For the EUV monochromator drive, the original synchronous motor was soon replaced by a stepper motor. Data acquisition initially used a multichannel scaler, and all channel timing and signal normalisation (to accumulated ion beam charge on a Faraday cup) operated on a single choice of preset settings. Over the years, this measurement control system graduated to a Commodore PET personal computer (first demonstrated in this laboratory in the group of H. H. Bukow) and then to an Apple IIe. The latter enabled varied and optimized settings of charge normalization and thus of data accumulation time as well as tailored stepper motor increments during a given recording of a spectrum or a decay curve. This option was used to optimize the beam time spent on more or less significant sections of a recording. For example, it became possible to cover several reference lines in a spectrum with good counting statistics while stepping quickly through less interesting sections, all the time relying on a single initial spectrometer setting and sometimes a single wavelength reference. In a decay curve, data points could be chosen with a dense pattern where—close to the foil—short-lived components mattered, and with wider spacings for the drawn-out tail dominated by slow components. Of course, it happened several times that in hindsight the experimenters would have liked to collect statistically better data also in the low-preset sections, as is demonstrated by examples below. Not all measurements went according to plan, and not all plans worked out as intended. Some of the experiences and mishaps are explained along the way as a means to help judge the experimental technique, its offerings, and its limitations.
In the range of elements and ion charge states covered in the present investigation, there is a trend that relates to the heavy-ion tandem accelerator employed. This is an electrostatic accelerator, and the ion beam energy can be chosen in a certain range limited by the machine parameters, such as the maximum high voltage at the terminal, which is about 4 MV. Negative ions (singly charged) are produced at about 90 keV and fed to the accelerator at ground potential. The ions are accelerated towards the high voltage terminal in the middle of the tank (at an ion energy of up to 4 MeV) and then passed through a stripper gas. The ions lose electrons and assume a charge state distribution that at an energy of 4 MeV for many elements has a maximum between q = 3+ and 4+. The maximum charge state fraction typically is of order 30%. In the second part of the accelerator, a positively charged ion with is further accelerated by the same high voltage U between the terminal and the ground and reach an energy of , in our example, 20 MeV. In order to reach 24 MeV, one has to use , which is available as a significantly lower charge state fraction (and thus lower ion beam current) from the terminal, and so on. Lower voltages are, of course available. The Bochum experiments with Cu beams used ion beam energies of 14 MeV up to 36 MeV. The latter energy requires , which is produced as a very small fraction (a few percent) of the ion beam after the gas stripper. To produce a beam current producing a sufficient signal in the experiment, the original ion beam current delivered by the ion source has to be correspondingly high. That it succeeded is one of the features that made the Bochum laboratory so exceptionally useful for beam–foil spectroscopy.
2.1. Ti
In the 1950s, Ti was considered an almost exotic material that was difficult to machine. Nowadays, the element is widely used for its many advantageous properties. When in the early 1980s experimenters asked the Bochum accelerator team for a Ti ion beam intended for future guest experiments with Stanley Bashkin [
71], one of the inventors of beam–foil spectroscopy, this was still an exploratory process. However, the operators quickly succeeded and turned Ti into one of the strongest ion beams available at this machine, with ion beam particle currents up to about 1
A on target. Owing to this success, signal rates turned out higher than with many other elements, which in turn permitted observations with higher spectral resolution. The advantage of high spectral resolution is, of course, the reduction of line blends, of which there can be many in such line-rich spectra as the EUV spectra of iron-group elements. Under the right conditions, the resonance lines of ions with a single or two electrons in the valence shell appear prominently. Theory has described such ions with
valence electrons for decades, but the achievement of accuracy has taken time. Na-like ions have been treated very well for about 40 years (see [
35]), but ab initio calculations for Mg-like ions have required a couple of decades longer to reach spectroscopic accuracy (for a recent historic view and new treatment, see [
36,
72]). With a third electron (or more) in the valence shell (Al-like ions), general purpose computations struggle notably. Given the limitations of atomic structure computations at the time, it is no surprise that much later computations of Al-like ions (see [
73]) find a fair number of inconsistencies between the various computations and experimental line identifications, including some based on Bochum beam–foil work [
74,
75]. Nevertheless, beam–foil work on Al-like ions [
49] verified assumptions on the variation of line intensity ratios in the
shell for a sequence of elements in the Al I isoelectronic sequence, and the unique properties of the beam–foil light source in combination with advanced computations of Si-like ions [
37,
38] helped to pin down inconsistencies in earlier term analysis, a problem that popped up with the availability of improved coronal spectra and will be explained in the section on Fe. An atomic structure problem closely related to the two-electron systems is the one-electron—one-vacancy system of singly excited Ne-like ions. For Ti, this is the spectrum Ti XIII, on which Bochum beam–foil work extensively investigated the level structure [
76,
77] and level lifetimes [
78]. At the same time, the Lund group of Litzén and Jupén was involved in studies of laser-produced plasmas of iron-group elements [
79], resulting in some parallel analyses (largely agreeing in the level structure and wavelength results with Bochum and Lyon beam–foil work) and several collaborative studies (among others, see [
52,
53,
80,
81,
82,
83]). A success of the beam–foil technique is the identification of the Ti XIII 2s
2p
3p
S
level decay (to the 2p
3s
P
level) by a combination of spectroscopy and lifetime measurements [
78]. Interestingly, in the same configuration, the 2s
2p
3p
S
level position and decay (two decay channels) are still disputed because candidates for one or both of the two lines are blended in most iron group elements, and the computed level lifetime does not significantly differ from those of many other levels, hence the experiment could not test this parameter for discrimination.
In the course of these studies, it was necessary to record survey spectra that helped to locate the line positions for the intended lifetime measurements. These surveys usually did not advance the accuracy of the literature knowledge on reference lines, but the spectra revealed additional information, only part of which has since been evaluated in detail studies. For example, Jupén has analyzed various yrast transition arrays in F- and Ne-like ions (see, for example, [
80]). (Yrast transition is a term phrased by nuclear physicists for transitions between levels of maximum angular momentum
ℓ for a given principal quantum number
n.) These transitions are particularly prominent in beam–foil spectra because they are fed by chains of other such transitions. Below, there are examples of how such yrast line clusters are identified and enhanced by the observation technique.
Most of the samples of spectra discussed in the following show unpublished data. Where spectra are compared/juxtaposed to each other, they often originate from measurements performed years apart and with different objectives. On purpose, the spectral ranges have not been cut down now to show only details of interest at the time but left as complete as seems reasonable, in order to show details that may possibly become of interest in the future.
Figure 1 shows Ti spectra close to the short-wavelength end of the operating range of the spectrometer. At an ion beam energy of 20 MeV (
Figure 1a), the charge state distribution is centered on
, and ion charge states
to
are expected to contribute. At an ion beam energy of 10 MeV (
Figure 1b), the charge state distribution is centered on
, and ion charge states
to
are expected to contribute. Both spectra show
n = 3–4 transitions up to the spectrum Ti XII. At the higher ion beam energy (spectrum (a)), the Ti XIII 3d–4f transition array shows with wavelengths near 10 nm. At the lower ion beam energy (spectrum (b)), the charge state Ti
is not notably produced. However, spectrum (b) shows several weak lines in this wavelength range too, which must originate from lower charge state ions. On the one hand, this example shows the power of charge state discrimination by the choice of the ion beam energy. On the other hand, spectra would have to be recorded at smaller ion beam energy intervals in order to systematically investigate the spectra for contributions of the individual charge state ions. In addition, the prominence of the 3d–4f yrast transitions in all charge states over transitions between levels of lower angular momentum is apparent. This prominence is due to the higher statistical weight (level population) of the 4f levels and the decays being unbranched.
The Ti XIII 3d–4f transition array also features in several other spectra (
Figure 2 and Figure 10, discussed below), demonstrating the power of observation in the second diffraction order or of employing a higher groove density diffraction grating. For this spectrum, a grating of 600 L/mm was used.
Figure 2 shows a beam–foil spectrum of Ti observed at an ion beam energy of 22 MeV. At this ion beam energy, the charge state distribution is centered on
, and ion charge states
to
are expected to contribute. A diffraction grating of high groove density (3600 L/mm) was used, and a line width (FWHM) of 0.006 nm was obtained. Only at such a high resolving power can most of the components of the Ti XIII 3d–4f transition array be resolved. The detail spectrum
Figure 2b is based on the same original data as Figure 1 of [
83], where the transition array is analyzed. The strongest transitions in the spectrum are identified by the spectrum number. A fair number of weak lines have not yet been identified.
Figure 3 shows beam–foil spectra of Ti recorded at an ion beam energy of 24 MeV. At this ion beam energy, the charge state distribution peaks at
and
, and ion charge states
to
are expected to contribute.
Figure 3b includes the second diffraction order image of the spectrum in (a). Hence, several bright lines of (a) also appear in (b) and can serve there as wavelength references in a spectral range that has no convenient first diffraction order Ti lines for this purpose. The two spectra comprise some 20 visually recognizable lines of unknown identity each.
Among the prominent lines of interest are the Ti XII and Ti XIII 4f–5g yrast transition arrays. A prominent line pair is formed by the Ti XIV 2s
2p
P
–2s2p
S
lines which have recently found theoretical interest [
32,
33] and are discussed for elements Ar to Ca in [
30]. An interesting point here is the line intensity ratio. An experimental determination with the present equipment is limited in precision by the steep slope of the calibration curve of the spectrometer-cum-grating [
84,
85]. The present data show almost the same apparent line ratio in first- and second-order observation. However, a calibration curve has been established only for the first-order observation, and it puts the result into rough agreement with prediction.
The Bochum beam–foil spectra of Ti have been investigated variously, most often with a view to the spectra Ti XIII and Ti XIV [
76,
77,
80,
81,
82,
83], and several of the publications have included plots of spectral sections. For the benefit of future interest in the raw spectra,
Figure 4,
Figure 5,
Figure 6,
Figure 7 and
Figure 8 show consecutive sections of survey spectra recorded at ion beam energies of 10 and 20 MeV, respectively. The charge state distributions expected at these energies are specified in the text for
Figure 1. Only a few prominent reference lines are labeled by the spectrum number, and a few vertical green marker lines indicate samples of similar lines in both sets of spectra to make orientation easier when looking for the changes of relative line intensities with variation of the ion beam energy. Since yrast lines are not so prominent in other light sources, these line clusters are labeled. A particularly striking example is the Ti X 4f–5g transition array in the 10 MeV spectrum in
Figure 6. Several sections of the 10-MeV spectrum have been recorded with a reduced preset for the ion beam charge normalization so that the scanning monochromator would advance farther in the allotted operation time. This leads to a seemingly wrong intensity ratio of the Ti XII 3s–3p line doublet at 46 nm and 48 nm, where the (expected to be) stronger line appears to be weakened by the shorter recording time per channel and the weaker line strengthened by a line blend with Ti VIII. In the long-wavelength section of the 10-MeV spectrum (
Figure 8) (where the spectrometer efficiency runs low [
85]), the visually recognized lines have been given markers; most of these lines have not yet been identified from the literature.
Thus far, all spectra concerned prompt electric dipole (E1) decays without spin change. Intercombination transitions (with a change of spin, thus connecting term systems of different multiplicity) have lower transition rates and consequently longer upper level lifetimes, by about two orders of magnitude [
86,
87] or more. For the E1-allowed decays, a typical upper level lifetime for ions of charge states as discussed so far would be expected in the range of 10 to 200 ps [
76,
78], whereas the upper level lifetimes of 3s–3p intercombination transitions would be expected in the range of 20 to 1000 ns. The former decays are visible as emission from the ion beam close to the exciter foil (the first few mm), whereas the latter are much weaker per section of the ion beam, but they survive out to distances of many cm from the foil. The EUV detection system at Bochum has a field of view that at the position of the ion beam is just under 1 mm wide. Most of the E1-allowed transitions have a decay length (level lifetime times ion velocity) that is shorter than this distance, and thus, in observations close to the exciter foil, most of the prompt emission happens in this observation window. The decay length of intercombination decays in moderately high charge state ions is on the order of 10 cm and more. This implies that the detection system sees less than 1% of a decay length of such levels, and, due to this geometry effect, the (intrinsically time-resolved) signal of such long-lived decays is roughly two orders of magnitude smaller than that of the resonance transitions.
Figure 9 demonstrates the flavor of the problem. Owing to the typical level structure with, say, triplet levels lying lower than singlet levels, the intercombination decays typically have longer wavelengths than the corresponding resonance lines. The prompt spectrum in
Figure 9a is of a wavelength range beyond the range of the prominent lines of
Figure 6,
Figure 7 and
Figure 8. Many rather weak lines appear, but none of the lines in the spectrum of
Figure 9a can be identified from reference tables. Spectrum (b) represents an observation of a 1 mm long section of the ion beam about 5 mm away from the foil. In a delayed spectrum such as in
Figure 9b, several intercombination transitions can be recognized in principle, but the line intensity is so low that observations require wide spectrometer slits for sufficient signals, and detection may be challenged yet. The Ti XI line is the 3s
S
–3s3p
P
transition in the Mg-like ion. It benefits from cascade repopulation, which is enhanced by a funneling effect of the cascades in the triplet term system. The 3s3p
P
level is predicted to have a lifetime of about 40 ns (see [
87]). In the Al-like ion, there are five lines of the Ti X 3s
3p
P
–3s3p
P
transition array. The
P
level is more highly populated than the other two owing to the statistical weight
, and its decay is unbranched. Lifetime predictions for this level run to the order of 300 ns (see [
87]). The
level should have a lifetime about a factor of 1/3 shorter, and the
level lifetime a factor of about three longer, and, for both levels, the decays are branched. Thus, each decay branch is individually weak. The signal that is in principle available per ion charge state is distributed over several levels and their decay channels; the signal is furthermore spread out over a longer flight path. This combination reduces the expected individual line intensities for the Ti X intercombination lines by about two orders of magnitude compared to the single intercombination line in Ti XI. The line pair 3s
3p
P
–3s3p
P
/3s
3p
P
–3s3p
P
has been seen clearly in heavier ions; the latter line is dominant, whereas the former one is a mere companion. This characteristic line pair differs from the broad structure seen here at 62.5 nm. It is likely that the observed structure originates from the Ti VIII 4f–5g transition array, which in a hydrogenic approximation is predicted at a wavelength of 63.28 nm. The Ti VIII transition array dominates the blend with the two Ti X intercombination transitions. An observation of the latter would require a much farther distance from the foil to enable a longer delay after excitation, when the yrast transition and its decay curve tail have practically died out.
In the Si-like ion, there are two decay branches of the lowest quintet level, Ti IX 3s
3p
P
–3s3p
S
. The upper level lifetime can be estimated near 500 ns (see [
87]). The term systems of the Si-like ions are more complex than those of Mg- and Al-like ions, and there is no notable cascade chain than would preferentially repopulate that quintet level. Consequently, the two intercombination lines are not prominent, although the ion beam energy of 8 MeV should favor the Si-like ion over Al- and Mg-like ions. The intercombination transition rates scale steeply with the charge of the ion core (with about the seventh power of the partly shielded ion core charge for these intra-shell transitions). Thus, it is somewhat easier to observe these intercombination lines in heavier elements such as Fe, Ni, or Cu (see examples below).
In
Figure 9b, there also are leftovers of yrast transitions. Their upper levels are short-lived (lifetimes below 100 ps), but they are replenished by a chain of cascades from higher-lying yrast levels.
Thus far, we have presented spectra of foil-excited Ti ions up to ion beam energies of 20 MeV.
Figure 10 shows a spectrum of the range 19 to 28 nm, recorded at an ion beam energy of 24 MeV. The charge state distribution is centered on
and
, and ion charge states
to
are expected to contribute. Much of the spectrum is rather similar to
Figure 3, but now there are all three 4f–5g transition arrays of Ti XII to Ti XIV present in the survey spectrum of
Figure 10a. At the present spectral resolution, the Ti XII 4f–5g (Na-like ion) transition array looks almost like a single line, Ti XIII 4f–5g (Ne-like ion) resembles a narrow structure with two major fine structure components, and, in the F-like ion Ti XIV, the 4f–5g array appears as a partly resolved wide multi-line cluster. Near a wavelength of 20 nm, the Ti XIII 3d–4f transition array shows in a second diffraction order. This array has been discussed by Jupén et al. [
83].
Figure 11 shows a beam–foil survey spectrum of Ti (in two sections) at an ion beam energy of 24 MeV. Several sections of this data set have served as the basis of annotated spectra in [
80]. Unfortunately, those figures have suffered in that journal’s procedure for digital archiving. A corresponding spectrum recorded at an ion beam energy of 20 MeV and with a poorer resolution has been presented in [
76], together with a simulated spectrum of Ti XIII.
2.2. Fe
Because of the particular prominence of Fe in the EUV spectra of the solar corona and the associated astrophysical interest, Fe has been investigated in many light sources. In the present context of spectra of the iron group elements, a particularly noteworthy group of publications by Del Zanna and (among others) his colleagues Mason, Young, and Storey cover many of the iron ions, benchmarked against the corresponding coronal spectra [
88,
89,
90,
91,
92,
93,
94,
95,
96,
97,
98,
99,
100]. A laboratory light source that comes close to the ultrahigh vacuum and electron density conditions of parts of the solar corona is the electron beam ion trap (EBIT) [
101]. Consequently, EBIT spectra have been used to help interpret solar corona spectra (for example, [
24,
25,
26,
27,
28,
29,
102]. The appearance of the spectra depends on the measurement conditions [
103,
104], as discussed with examples below. Among the early beam–foil work, there has been a noteworthy activity on the Fe spectra in the Lyon group of Buchet and Buchet-Poulizac and by their colleagues at Caen [
105,
106,
107]. Jones and Johnson at Brookhaven were among the first to study Fe in the EUV using a multichannel detector system [
68,
69]. For earlier presentations of Fe beam–foil work at Bochum (much of it done in collaboration with colleagues from Lund), see, for example, [
49,
50,
57,
58,
59,
60,
75,
108,
109].
In the beam–foil spectrum in
Figure 12, about 90 lines can be discerned by the eye. The same spectrum is presented on a linear and a logarithmic scale in order to help with the orientation in the logarithmic survey spectra discussed later. The spectrometer slits used here were half as wide as in most of our survey spectra (shown previously), and thus the spectral resolution is correspondingly higher. Various line groups that are only partly resolved in the survey spectra can be better disentangled in this spectrum, at the cost (and limitation) of accelerator operating time.
Figure 13 combines two relatively highly resolved beam–foil spectra. About 30 lines can be discerned visually, not all of which are known. For example, the profile of the Fe XVI 3p–3d line at 26.2976 nm [
11] suggests a blend with an unknown line, whereas the major contributors to the similarly shaped line at 26.5 nm are known to belong to Fe XIV (26.4785 nm) and Fe XVI (26.5003 nm), respectively. The strongest line in this figure (Fe XV at 28.4164 nm) is neighbored by weaker lines that fall into the wings of the strong line. Evidently, the spectral resolution of these data is not quite sufficient for separating all the details. However, the spectrometer settings are always a compromise of intended resolving power and affordable operating time. Measurements with a similar spectral resolution as in
Figure 12 and
Figure 13 have been tried at longer wavelengths too, but the extraction of information suffered from a weaker signal (due to the line intensity distribution in the Fe spectrum, the decreasing efficiency curve of the spectrometer [
85]) and the (relatively) higher noise.
Figure 14 and
Figure 15 juxtapose beam–foil and EBIT spectra (both on log scales). The underlying raw data are the same as presented in [
104]. The beam–foil data have been garnered with a scanning grazing-incidence monochromator (grating
R = 2.2 m, 600 L/mm) equipped with a channeltron serving as the detector. The experiment required about a day (and night) of accelerator time. The EBIT experiment [
28,
29] used a grazing-incidence flat-field spectrograph (variable line-spacing grating of
R = 5 m and approximately 1200 L/mm) [
110,
111]; the spectrum was recorded on a CCD chip with an exposure time of 30 min. The spectrograph has no entrance slit but images the 60
m wide zone of the stored ion cloud exposed to the energetic electron beam directly onto the detector. The CCD chip has an intrinsic background with some structure that further modeling might reduce in the presentation. However, the signal-to-noise ratio of both measurements is of the same order of magnitude, with the EBIT recording being much faster. The spectrograph grating used shows the second order of diffraction images well; the spectrograph was set for observation of the 20 nm to 44 nm wavelength range in the first order. Spectroscopically, the two spectra are rather similar; the line width of the scanning monochromator is constant as a function of wavelength, whereas, with the flat-field spectrograph, it is slightly smaller in the wavelength range of
Figure 14 and increasing towards long wavelengths. This may partly be a result of imperfect focusing but is mostly a consequence of the flat image field being a very good, but imperfect approximation. The focal curve of variable line spacing gratings as used in flat-field spectrographs is intentionally distorted from the basic Rowland circle perimeter to feature a straight section that can be matched by a flat detector chip. The technical specification by the manufacturer (Hitachi) of the grating used in the aforementioned flat-field spectrograph states a wavelength working range from 5 nm to 20 nm. For the electron beam ion trap spectra of Fe and Ni (below), the spectrograph was set to monitor the wavelength range from 20 nm upwards, which is fully outside the manufacturer-specified operating range. Evidently, the focusing works well beyond the prescribed wavelength range, but for wavelengths longer than some 35 nm, the line images become increasingly wider.
The important differences between the beam–foil and EBIT spectra in
Figure 14 and
Figure 15 concern the physical conditions in the light source. Beam–foil spectra contain practically electric dipole (E1) transitions only because of the inherent time resolution and the typical level lifetimes. The excitation differs between beam–foil interaction at a high (solid-state) electron density and the electron impact excitation at very low electron density in an electron beam ion trap (which resembles excitation by Maxwellian electrons in the dilute gas of the solar corona). Consequently, in an EBIT, most of the level population is in the ground configuration, whereas, in the ion–foil interaction, the excitation reaches a high level and then the population pours down in cascades. The massive differences in the spectra have been demonstrated in [
103,
104]. Astrophysical plasmas can contain all elements at once, whereas the laboratory ion beam is elementally pure. The EBIT is in between; in the EBIT experiment with Fe, injection of ironpentacarbonyl (Fe(CO)
) was used, which disintegrates when hit by the electron beam in the trap, hence the spectra may comprise emission from C, O, and Fe ions. The heaviest ions are trapped best (and reach the highest charge states), which leaves Fe as the strongest contributor to such a spectrum. The strong Fe EUV lines Fe IX near 17.1 nm, Fe X near 17.45 nm (see [
25]), Fe XII near 18.7 nm, Fe XII near 19.4 nm (see [
26]), Fe XIII near 20.3 nm, Fe XIV near 21.1 nm (see [
27]), etc. show up in their second diffraction order positions, as well as the strong O VI lines at 15.0 nm, 17.3 nm, and so on.
A wavelength range near 21 nm has been investigated at the Livermore EBIT in detail in [
27], using a high resolution spectrograph [
112]. A further section of the high-resolution spectrum has been added recently [
113]. The wavelength interval 28–35 nm investigated with a medium resolution spectrograph has been discussed in [
28,
29]. In this wavelength band, the difference between the high-electron density excitation in the beam–foil interaction (
Figure 14a and
Figure 15a) and the excitation by a low-density electron beam (
Figure 14b and
Figure 15b) is particularly striking. The ion charge states present in both data sets are rather similar, but the relative emission signal of certain types of levels is much stronger in the foil-excited ion beam [
104].
Figure 16 shows samples of prompt and delayed spectra of foil-excited Fe ion beams. In Reference [
31], it has been discussed how the isotope-pure beam–foil light source suffers from a scarcity of wavelength reference lines in many spectra, especially in delayed ones. In prompt spectra (with reference lines), the signal of the decays of long-lived levels is too weak to be seen against the competition by short-lived level decays. Away from the exciter foil, after suitable delays, the ‘slow’ decays that have ‘survived’ become dominant, but the reference lines have died out. The spectra in
Figure 16 demonstrate a pathway to calibrate delayed spectra (b,c) that have no lines in common with the prompt spectra (in a) that have known reference lines. However, the changes of a heavy-ion accelerator to a different ion beam energy imply small uncertainties in the ion beam trajectories, which cause uncertainties in the Doppler correction in the observations of a fast ion beam, on top of the limited mechanical reproducibility of a scanning monochromator as was used here. The lines seen in the prompt spectrum can easily be recorded with high statistical reliability. The lines observed in the delayed spectra are statistically much poorer, in addition to the larger line widths caused by wider spectrometer slits necessitated by the scarce signal. In the delayed spectra, a number of line positions have been marked by visual inspection. Owing to the line width, many lines overlap with their neighbors, and more blends are expected. Computations have been undertaken [
59] to identify the many intercombination transitions expected in S- and Cl-like ions. Many of the suggested candidates are labeled in
Figure 16b,c. The spectral feature at 25.7 nm is expected to consist of three components with different lifetimes. This complexity suggests that the present classifications [
59] have to be considered as preliminary until better resolved data of higher statistical reliability and at further time steps become available, as well as accurate computations for all charge states expected. Recent ab initio computations (such as [
32,
33,
34,
36,
37,
38,
39,
40,
41,
42,
43,
44,
114]) appear to be on the right path and reach an accuracy that is about an order of magnitude higher than what was available at the time of the beam–foil experiments described here.
The measurement problem is further discussed below in the section on Ni. There is a transition in the the Si-like ion, Fe XIII 3s
3p
P
–3s
3p3d
F
[
96], at a wavelength of 23.903 nm that appears at ion beam energies between those of
Figure 16a,b and at delays shorter than that of
Figure 16b [
50]. This line has been recognized in spectra of the solar corona, where its wavelength can be measured more accurately than in the delayed beam–foil spectra, and, therefore, its wavelength may then be used to calibrate the latter.
2.3. Ni
Ni is less abundant than Fe but not drastically so. Thus, it is of high astrophysical interest. A problem lies in the fact that Fe and Ni emissions populate overlapping spectral ranges. Therefore, the spectral diagnostics of stellar plasmas, in which both elements are present, require information on both elements and their spectra. Partial beam–foil spectra and decay curves of highly charged Ni ions have been evaluated previously (see [
55,
56,
115,
116,
117,
118,
119] and several multi-element papers cited above).
Examples of three topics are discussed here:
- (a)
moderately highly resolved prompt spectra and slightly delayed spectra in the range from 14 nm to 23 nm,
- (b)
comparison of beam–foil and EBIT spectra in the range 20 to 44 nm, and
- (c)
survey spectra recorded with a delay to enhance the visibility of decays of long-lived levels; 3s–3p and 3p–3d intercombination decays.
Figure 17 shows two moderately highly resolved spectra: a prompt spectrum and a slightly delayed spectrum in the wavelength range 14–23 nm. These data have been presented before (see Figures 4 and 5 of reference [
56]); they are shown again for the context of this discussion and to indicate some progress of the identification process. At the time, the recording of delayed spectra was started as a tool to reduce the complexity of the observed spectra. The prompt spectrum in
Figure 17a is so line-rich that, in the wavelength interval between 15 nm and 22 nm, many lines merge into a wide hump. Actually, at the time of the experiment, none of the lines in the hump could be identified. In the various delayed spectra then recorded (for an example, see
Figure 17b), much of the spectral hump was gone and thus recognized as having originated from a plethora of decays from possibly multiply excited and hence short-lived levels. However, incidental line blends were still frequent and attempts at identification failed. Later work at significantly longer delays (up to some 20 ns, the maximum feasible with the given vacuum chamber size) and at various ion beam energies revealed that the wavelength range from 17 nm to 26 nm comprises the 3p–3d intercombination decays in Si- to Ar-like ions of Ni [
119]. The aforementioned newer computations of many of these ions [
37,
38,
39,
40,
41,
42,
43,
44,
114] might support fresh attempts at line classification in delayed spectra of this wavelength range. Moreover, many of the lines in the prompt spectra longwards of the hump can nowadays be identified with information from considerably augmented spectral data bases [
11].
A key to the analysis of the prompt spectrum in
Figure 17a is the line just above 22 nm in wavelength, which has meanwhile been identified with the Ni XVIII 3p
–3d
transition at 22.0424 nm [
11]. This is a rather weak line in this spectrum because the Na-like ion charge state is barely produced at an ion beam energy of 24 MeV. However, the line is clean enough to serve as a reference wavelength anchoring the wavelength scale in the measurement. Based on this line identification, a number of further identifications can be made by wavelength, based on the NIST ASD database [
11]. The NIST data base lists many more transitions in the wavelength range of
Figure 17, but, at the present experimental settings and conditions, there are many line blends to consider. Therefore,
Figure 17a identifies only ten spectral features with spectrum numbers. Note that the 22-nm line has practically died out by the time delay of
Figure 17b, although the upper level is readily repopulated by radiative cascades. Note also that the strongest line in the delayed spectrum, near 21.01 nm, has an amplitude of about 100 counts. It is likely to originate from the decay of a long-lived level. The signal of this line, retro-estimated for the position of the foil, would not be much higher than 100 counts, and thus the line makes up part of a weak line blend there but not more. Consequently, the two spectra have no clean lines in common, and the wavelength scale of the delayed spectrum rests on the mechanical reproducibility of the spectrometer drive alone. This measurement uncertainty is estimated here as ±0.015 to 0.02 nm. This leaves the aforementioned problem: There is no wavelength reference found yet that would tie the wavelength scales of the downstream measurements directly to well known lines in the prompt spectra, and thus a wavelength uncertainty caused by the properties of the spectrometer drive limits the measurement accuracy. To bridge this gap, beam–foil spectra of Ni with short delays of only 0.1 to 0.2 ns (to suppress some blends with short-lived level decays while exploiting the cascade feeding of reference lines) might offer a path forward.
An alternative approach is an accurate computation of suitable reference lines for delayed spectra, which for a long time has been lacking. The strongest line in the delayed Ni spectrum has previously been identified with guidance from much earlier Hartree–Fock calculations [
120] and technically with the charge state distribution changing as a function of ion beam energy as originating from the Si-like spectrum (Ni XV) (see Figure 2 of [
56]). In a set of line identifications in the solar corona, based on such delayed beam–foil spectra [
60], the transition was identified as 3s
3p
P
–3s
3p3d
F
. It has not been possible yet to associate this transition with any solar corona emission line as reported by Dere [
121]. Unfortunately the Ni XV line appears to be too weak to show in the
/EIS spectra [
122], so that a good solar wavelength value is not yet available. Interestingly, this line has been seen in the Livermore electron beam ion trap, at a wavelength of 21.013 ± 0.002 nm [
27], which appears to be the most accurate measurement so far. Computations by ab initio techniques employed by Vilkas and Ishikawa [
38] have yielded a wavelength value of 21.015 nm that is much closer to measurement than the earlier semi-empirically scaled computations. The even more recent computations by Jönsson et al. [
39] have reached a comparable accuracy (and an almost identical wavelength result of 21.013 nm in this case). However, the agreement of computations with each other is no proof, nor is a single data point agreement with an experimental result that involves the aforementioned calibration limitations. The closest element for which solar coronal data offer a match is Fe (see [
60]). At the time, the association was based on the comparison of a known to be not quite accurate theoretical isoelectronic trend with not yet assigned lines in the solar spectrum. The ab initio multi-reference Møller–Plesset computations of the Ishikawa group [
37,
38] corroborated the tentative astrophysical line assignments and the beam–foil identifications for a sequence of elements. A decade later, Jönsson et al. [
39] applied a different computational approach and obtained almost identical results.
Table 1 recapitulates the work on the 3s
3p
P
–3s
3p3d
F
transition in Si-like ions.
It is good to find that the purely experimental approach with the aforementioned technical limitations has found a significant and unblended line in the delayed spectrum, the wavelength of which agrees well with accurate computations. The reliability of the latter for this 3s3p P–3s3p3d F transition is better than ±0.01 nm and clearly surpasses the present experimental uncertainty. Unfortunately, a computation found to yield excellent results in one case is not guaranteeing the same high quality in others, as evidenced by the differences between computational results for several elements. Most lines in this kind of delayed spectra belong to ions with a more than half filled valence shell (P-like, S-like, etc.), and that increases the complexity of the problem. However, these computations have at least some excellent results to their credit. It should therefore be feasible to identify many more lines in the delayed spectra at the present level of experimental and computational accuracy.
As mentioned above in the subsection on Fe, high-resolution nickel spectra have been recorded at the Livermore electron beam ion trap EBIT (see, for example, [
27]). The spectrograph used [
112] produced highly resolved spectra of wavelength bands that matched the individual detection bands of the
spacecraft, but it did not permit observation beyond wavelengths of about 25 nm, where a smaller, medium-resolution flat-field spectrograph [
110,
111] was employed instead [
28,
29]. The spectra obtained with this instrument are close in resolution to the beam–foil survey spectra of Ni [
56] that have been discussed above. It seems appropriate to inter-compare the beam–foil and EBIT Ni spectra in their wavelength range of overlap, 20–44 nm (see
Figure 18 and
Figure 19, at the same spectrograph settings as for
Figure 14 and
Figure 15). Since Ni is introduced into the ion trap as nickelocene (Ni(C
H
)
), there are no second order calibration lines of oxygen in this spectrum, in contrast to Fe (see
Figure 14b and
Figure 15b). The line of Ni XV near 21.0 nm that provides a key to the interpretation of the delayed beam–foil spectrum in
Figure 17b appears as one of the weaker lines in the EBIT spectrum of
Figure 18b, alongside many other Ni lines, most of which are known [
11]. As mentioned in the discussion of Fe data, the electron beam ion trap camera signal appears on a thermal background (at cryogenic temperature), but on a basis of equal measurement time, the signal-to-noise ratio is much better than with the scanning monochromator and its channeltron detector. Both experiments and detection systems produce and reach about the same charge ions, but the excitation differs drastically. In the ion–foil interaction at high electron density, the level population depends very much on the statistical weight of the upper level and on cascade repopulation, while, in the low electron beam ion trap, the excitation is beginning largely from ground state ions (see [
103,
104]). This difference is recognizable in the present Ni spectra by significantly different relative line intensity ratios.
In the EBIT part of
Figure 19, a feature already discussed in
Figure 15 (on Fe) recurs: besides the rather narrow lines from the first diffraction order images, the long-wavelength section shows a number of wider lines with smooth profiles indicative of a good statistical reliability. Many of these lines are the second-diffraction order images of prominent resonance transitions in Ni XII and higher, whose wavelengths fall into the range 15 nm and higher, that is, the first-diffraction order images lie outside the present image field. The notable widening of the spectral lines in the long-wavelength part of the EBIT spectrum is a result of the geometry of flat-field spectrographs (as explained in the Fe section above); the spectrograph wavelength setting used here is outside the grating manufacturer’s suggested operating range. Owing to the inherent shift of similar transitions from Fe (
) to Ni (
) to shorter wavelengths, the first-diffraction order lines detected in the EBIT spectrum of Ni fall mostly into
Figure 18b and only a small part into
Figure 19b. Hence, the second-order lines happen to dominate
Figure 19b. Nevertheless, there are a number of first-diffraction order lines at the longer wavelengths, and some of them appear more strongly in the EBIT spectrum than in the spectrum from the foil-excited ion beam.
Figure 20 and
Figure 21 show survey spectra that have been recorded with a delay after the excitation in order to enhance decays of long-lived levels, such as the 3s–3p and 3p–3d intercombination decays. Because the signal rate in such delayed spectra is intrinsically much lower than that in prompt spectra, the measurements could only be afforded at the Bochum tandem accelerator laboratory with its capability of uncommonly high ion beam currents. Individually, the spectra might be seen as not very exciting and of rather poor signal-to-noise ratio. The combination shows how reproducible even seemingly weak spectral features are, for example in the wavelength interval 30–32 nm. The upper spectrum shows a group of four lines at a delay of 2 ns, of which two survive till the lower (delayed) spectrum at 10 ns. In this wavelength band lie several Ni XVIII lines (3s–3p transitions near wavelengths of 29 nm and 32 nm, respectively), the upper levels of which are not very long lived but are replenished by cascades. Near 25 nm, the Ni XVII resonance line can similarly be discerned, and also a 3s–3p transition with cascade feeding.
The green bands in
Figure 20 and
Figure 21 mark wavelength ranges in which the spectra reveal significant line emission from long-lived levels. From 17.5 nm to about 26 nm is the range of the 3p–3d intercombination transitions from the decay of long-lived levels. At a delay of 2 ns, the spectrum is dominated by the 21-nm line in Ni XV that has been discussed above, but, at 10 ns after excitation, this line has lost its dominance, and another spectral feature near 22.2 nm, a blend of 3p–3d transitions in Ni XV and Ni XVI dominates. In fact, the pattern of relative line intensities has changed in the entire line group, signaling the very different level of lifetimes contributing. One must not forget that the charge state distribution after foil excitation depends on the ion beam energy. At not much lower energies than used for the spectra shown, a strong contribution is expected near 22.6 nm from several intercombination transitions in S-like Ni XIII (see prompt and delayed spectra shown in [
56]).
In the wavelength band 36–48 nm, we find several 3s–3p intercombination transitions in Mg- to Si-like ions. These are Ni XVII 3s S–3s3p P at 36.680 nm, the transition array Ni XVI 3s3p P–3s3p P (wavelengths 36.85 nm to 43.14 nm), and the Ni XV 3s3p P–3s3p S line pair at 41.7 nm and 44.0 nm, respectively. Besides these well-established transitions, there are a few more unidentified candidate lines in this neighborhood (for example, near 43 nm and 46.5 nm). Several further groups of lines of long upper level lifetime have been noted and marked in the long-wavelength section of the delayed spectra. These spectral features (near 51 nm, 54.2 nm, 57.7 nm and 62.7 nm) have not been identified yet. They have not been systematically searched for, but are foundlings in exploratory measurements “looking for what’s there," even as the literature does not know of anything in the area yet.
2.4. Cu
As an odd-numbered element, Cu is astrophysically not very abundant, and consequently of little interest in that field. However, terrestrial laboratories use Cu conductors and antennas in vacuum chambers, and therefore Cu does appear in spectra of many hot plasmas, intentionally or not. It is about as easy to produce an ion beam of Cu as it is for Ni, and thus the signal rate can be conveniently high in beam–foil experiments.
At an ion beam energy of 36 MeV, the charge state distribution [
67] behind the exciter foil peaks at
(Si-like ions of Cu) and reaches up to
(Ne-like). This is almost as high (in terms of atomic systems) as 24 MeV for Ti, which has been used to study the F- and Ne-like spectra and level lifetimes of Ti. However, in Ti, this was achieved with
ions, which are much more abundant in the corresponding charge state distribution at the gas stripper, and thus a much better signal rate resulted. It is easy to see that isoelectronic sequences cannot be studied at will with a given accelerator. Consequently, our studies of iron-group elements aimed at F- and Ne-like ions near Ti, Mg- to Si-like ions for Fe, Ni, and Cu, and ions with more electrons for elements Mn through Zn.
Much of the Bochum beam–foil work on Cu (with emphasis on intercombination transition wavelengths and rates) has already been published. Some of the early presentations of beam–foil survey spectra of Cu (such as in [
115]) have suffered from the later digitization for archiving process. In these line-rich spectra, there has been no significant progress towards line identification, and therefore the prompt survey spectra are not shown again. A considerably greater success has been achieved in (delayed) detail spectra such as those of the intercombination decays in Mg- through Si-like spectra [
55,
56,
115,
119] and in delayed spectra of Si- to Ar-like ions [
59,
123]. For Cu, the simple spectra of Na- and Mg-like ions can be produced at the Bochum laboratory only at the performance limit of the accelerator system. It seemed worth trying to make use of the high ion beam current available and record higher-resolution spectra at lower ion beam energies, and consequently the Bochum beam–foil data holdings on Cu have an emphasis on the lower charge state ions.
Figure 22 shows an example, a spectrum with many lines (about 50 are discernible by eye), but with merely two lines marked with a spectrum number. The ion beam energy of 16 MeV is too low to produce any Na- and Mg-like ions with their well-known resonance lines. The literature knowledge (with the example of the NIST ASD database [
11]) of the spectra of lower charge states is progressively poorer. Chance coincidences of listed lines and observed features are meaningless, if corresponding other lines of the same spectra cannot be identified as well. Another problem is the wavelength measurement with a mechanically scanning monochromator that needs at least one reference line to ascertain the mechanical shifts of the day. The sample spectrum in
Figure 22 is the last part of a sequence of spectra recorded at ion beam energies up to 31 MeV (spectra shown in [
123]) that provides several wavelength references, but there were no recordings made at the same occasion that checked the high energy situation again right after running several measurements at the lower ion beam energy. Hence, this spectrum carries the same overall uncertainty of about 0.02 nm (half a line width) as many of the delayed spectra discussed above. Further line identifications are required to ascertain the anchor line identities and to determine the accuracy and precision of the wavelength scale.
With the contents of the NIST ASD database so slim for the charge states that are produced at an ion beam energy of 16 MeV, one might look for theory to indicate promising lines that are to be identified. For example (see
Table 1), in Si-like Ni, the 3s
3p
P
–3s
3p3d
F
transition wavelength has been computed by two groups practically identically and within the 100 ppm uncertainty of the experimental value (see discussion above and [
38,
39]). For the same system in Fe, one of the computations [
38] comes similarly close to the solar corona wavelength measurement, while the other differs by about 400 ppm. For the same system in Cu, the same computations agree with each other within 100 ppm, but the experimental error measure is an order of magnitude larger, and the only available beam-foil measurement of this line does not yield a reference that is suitable for a determination of the computational accuracy. This inconsistency along the isoelectronic sequence issues a warning about the need for testing and further refinement for all such computations. They may represent the best ability and knowledge, but without intrinsic tests of accuracy, their quality remains uncertain. The example just mentioned is of an ion with four electrons in the valence shell (two of them in the open sub-shell); below is an example of an ion with more electrons in the same shell, and it shows that each atomic system poses different challenges.
This being said, the computations are most helpful for spectral modeling and for some details and certain trends. For example, in delayed spectra of Cu, there are groups of weak lines in the vicinity of the intercombination lines of Mg- through Si-like ions. Theory [
123] suggests that these belong to intercombination decays of sextet levels in P-like ions. Decays of three 3d
levels in such P-like ions have been discussed in [
60], and the corresponding levels in S-like ions have been discussed in [
124]. These levels are long lived because they differ by more than two units in total angular momentum from the
ground state, and thus they cannot decay there by an electric dipole transition. As a result, there are quite a number of excited levels with millisecond lifetimes. This has been corroborated by the recent computations by Wang et al. [
40].
With such long lifetimes, the signal expected in the beam–foil observation geometry is too weak to be notable, by several orders of magnitude. Such long-lived decays have, however, been seen as cascades in experiments at a heavy-ion storage ring (see, for example, [
125,
126,
127,
128,
129]). Amusingly, the presence of such slow cascades has been proven by these decay curve measurements that involved a very limited spectral resolution, but there is no practical method available yet to perform direct spectroscopy on such long-lived excited levels. The long lifetimes call for time-integrated observations at a very low particle density, such as in an EBIT; however, the excitation efficiency of such levels that are not easily populated directly from the ground state is very low there. The same problem pertains, of course, to many atomic systems with an open
valence shell.
The spectrum of
Figure 22 is only indirectly related to the measurement problems in the delayed spectra, that is, by the need to find wavelength references. This spectrum has been recorded close to the exciter foil, and, consequently, it should be dominated by the emission of moderately short-lived levels, of Cu ions around charge state
. Level populations usually are the highest for the ground state, and lower for more energetic levels. Consequently, in a Cl-like atomic system, one should expect the decays of the lowest (displaced) term, the 3s3p
S
level, to the two 3s
3p
P
levels of the ground term, to give rise to prominent lines. According to the computations by Wang et al. [
43], these lines have wavelengths of 27.175 nm and 29.465 nm, respectively. The calculated upper level lifetime is 148 ps; the wavenumber difference of the two lines is given by the (experimentally known from isoelectronic systems) fine structure interval of the 3s
3p
P
ground term. Transitions of this type have been seen in many beam–foil spectra.
Let us start a first attempt at line identification in
Figure 22 from the predicted wavelengths. There is no particularly bright line in the spectrum, nor is there a prominent candidate line pair right at the computed wavelengths, but several possible candidates lie in the vicinity. If a line near 27.175 nm was the right line to start with, a candidate of peak signal 150 counts, the second line should show a peak signal of about 60 counts (weaker than the first by the predicted line ratio of 1:2.4), which would make it part of an unresolved line group. If instead the brightest line of the spectrum, near 27.0 nm, with a peak signal of 350 counts, was associated with the stronger line of the doublet mentioned, the other line should appear near 29.3 nm, where no suitable second line is seen. There are several more options. Guided by older experimental work on many other elements, the lines of present interest have been found in beam–foil spectra of Cu, too, at wavelengths of 27.480 nm and 29.814 nm, respectively [
50], 1% away from the predictions by Wang et al. [
43]. Evidently, the two experimental wavelengths for the most fundamental transition array (between the ground term and the first excited term) in Cu XIII differ somewhat from even very good recent computations. 1% may seem a small error, but, in the case of Si-like Fe spectra, we have discussed agreement of experiment and theory at the 100 ppm level, which is two orders of magnitude better than this 10,000 ppm error achieved by a similar computational approach for a Cl-like Cu ion. Moreover, beam–foil lifetime measurements [
50] point to a value in the middle of the factor-of-two scatter range of the various predictions of transition rates.
In the S-like spectrum Cu XIV, a number of intercombination decays of 3s
3p
3d
D
levels to the 3s
3p
ground configuration fall into or close to the wavelength range of the spectrum in
Figure 22, but the predicted lines are not recognizable here. This is not a shortcoming of theory, but is due to a property of the beam–foil light source. Most of the upper levels have theoretical lifetimes (see, for example, [
41]) in the range of a few nanoseconds. Such decays are best seen away from the exciter foil [
123] because close to the foil the multitude of decays of short-lived levels dominates. Any attempt at spectrum analysis has to take the observational setting and conditions into account. These conditions strongly influence which transitions are likely to be seen.