Figure 1.
Fish farm facilities: (a) water supply system; (b) discharge water system; (c) fish farm.
Figure 1.
Fish farm facilities: (a) water supply system; (b) discharge water system; (c) fish farm.
Figure 2.
Monthly average tidal status, Southern sea, Korea.
Figure 2.
Monthly average tidal status, Southern sea, Korea.
Figure 3.
Block diagram of the design process for the hydraulic turbine.
Figure 3.
Block diagram of the design process for the hydraulic turbine.
Figure 4.
Schematic installation diagram of an offshore small hydropower plant.
Figure 4.
Schematic installation diagram of an offshore small hydropower plant.
Figure 5.
Three dimensional (3D) geometry of a propeller type turbine: (a) turbine; (b) generator, runner, and guide vane; (c) dimension of runner.
Figure 5.
Three dimensional (3D) geometry of a propeller type turbine: (a) turbine; (b) generator, runner, and guide vane; (c) dimension of runner.
Figure 6.
Unstructured prism grids: (a) inlet pipe and generator; (b) guide vane; (c) runner; (d) draft tube.
Figure 6.
Unstructured prism grids: (a) inlet pipe and generator; (b) guide vane; (c) runner; (d) draft tube.
Figure 7.
Grid independency test of the tubular turbine (vertical dotted line represents the used grid).
Figure 7.
Grid independency test of the tubular turbine (vertical dotted line represents the used grid).
Figure 8.
Y+ contour of the runner.
Figure 8.
Y+ contour of the runner.
Figure 9.
Prototype turbine domain for computational analysis.
Figure 9.
Prototype turbine domain for computational analysis.
Figure 10.
Experimental layout and devices: (a) pressure and temperature sensor; (b) offshore small hydro power plant.
Figure 10.
Experimental layout and devices: (a) pressure and temperature sensor; (b) offshore small hydro power plant.
Figure 11.
Different losses in the hydraulic turbine (Pw = hydraulic power, Ps = shaft power, and PG = generator power).
Figure 11.
Different losses in the hydraulic turbine (Pw = hydraulic power, Ps = shaft power, and PG = generator power).
Figure 12.
Comparison of turbine efficiency across various runner vane opening angles.
Figure 12.
Comparison of turbine efficiency across various runner vane opening angles.
Figure 13.
Efficiency changes according to runner vane and guide vane opening angles.
Figure 13.
Efficiency changes according to runner vane and guide vane opening angles.
Figure 14.
Flow rates, power versus runner vane, and guide vane opening angles.
Figure 14.
Flow rates, power versus runner vane, and guide vane opening angles.
Figure 15.
Blade-to-blade pressure and velocity contours (span = 0.5).
Figure 15.
Blade-to-blade pressure and velocity contours (span = 0.5).
Figure 16.
Blade-to-blade velocity vector and velocity streamlines (span = 0.5).
Figure 16.
Blade-to-blade velocity vector and velocity streamlines (span = 0.5).
Figure 17.
Shapes of short and long guide vanes.
Figure 17.
Shapes of short and long guide vanes.
Figure 18.
Vane-to-vane velocity streamline distribution of guide vanes and runner vanes: (a) at short chord; (b) at long chord.
Figure 18.
Vane-to-vane velocity streamline distribution of guide vanes and runner vanes: (a) at short chord; (b) at long chord.
Figure 19.
Turbine loss analysis.
Figure 19.
Turbine loss analysis.
Figure 20.
Guide vane attached to the generator side (short chord).
Figure 20.
Guide vane attached to the generator side (short chord).
Figure 21.
Vane-to-vane pressure and streamline distribution of guide vanes and runner vanes: (a) pressure contours; (b) streamline contours.
Figure 21.
Vane-to-vane pressure and streamline distribution of guide vanes and runner vanes: (a) pressure contours; (b) streamline contours.
Figure 22.
Changing the shape of guide vanes with short chords to make them streamlined.
Figure 22.
Changing the shape of guide vanes with short chords to make them streamlined.
Figure 23.
Vane-to-vane streamline distribution of guide vanes and runner vanes: (a) streamline distribution before shape change; (b) streamline distribution after shape change.
Figure 23.
Vane-to-vane streamline distribution of guide vanes and runner vanes: (a) streamline distribution before shape change; (b) streamline distribution after shape change.
Figure 24.
Vane-to-vane pressure and streamline distribution of guide vanes and runner vanes when chords were long: (a) pressure distribution; (b) streamline distribution.
Figure 24.
Vane-to-vane pressure and streamline distribution of guide vanes and runner vanes when chords were long: (a) pressure distribution; (b) streamline distribution.
Figure 25.
Changing the shape of the runner vane.
Figure 25.
Changing the shape of the runner vane.
Figure 26.
Pressure and streamline distribution between guide vanes and runner vanes: (a) pressure contour after shape change; (b) streamline contour after shape change.
Figure 26.
Pressure and streamline distribution between guide vanes and runner vanes: (a) pressure contour after shape change; (b) streamline contour after shape change.
Figure 27.
Comparison of efficiency and flow rate according to guide vane opening (RV-19~24°).
Figure 27.
Comparison of efficiency and flow rate according to guide vane opening (RV-19~24°).
Figure 28.
Performance changes according to rotational speed and tidal level: (a) rotational speed versus flow rate; (b) rotational speed versus efficiency; (c) rotational speed versus power.
Figure 28.
Performance changes according to rotational speed and tidal level: (a) rotational speed versus flow rate; (b) rotational speed versus efficiency; (c) rotational speed versus power.
Table 1.
Design specifications of the tubular turbine.
Table 1.
Design specifications of the tubular turbine.
Description | Dimension |
---|
Theoretical head (m) | 15.00 |
Flow rate (m3/s) | 1.13 |
Max. power (kW) | 100 |
Rotational speed (rpm) | 850 |
Runner blade | 4 |
Guide vane | 9 |
Table 2.
Main design parameters of the turbine blade.
Table 2.
Main design parameters of the turbine blade.
Description | Dimension |
---|
Runner blade diameter (m) | 0.50 |
Runner blade | 4 |
Hub diameter (m) | 0.25 |
Hub ratio | 0.50 |
Table 3.
Grid quality of the tubular turbine.
Table 3.
Grid quality of the tubular turbine.
Description | Elements | Nodes | Min. Y+ | Max. Y+ |
---|
Inlet pipe | 1,089,171 | 299,348 | 2.60 | 64.85 |
Guide vane | 562,824 | 152,061 | 1.41 | 360.67 |
Runner | 1,583,989 | 453,384 | 1.25 | 343.16 |
Draft tube | 1,066,591 | 287,254 | 1.33 | 85.19 |
Total | 4,302,575 | 1,192,047 | | |
Table 4.
Grid convergence uncertainties in the numerical solutions.
Table 4.
Grid convergence uncertainties in the numerical solutions.
No. | Nodes | Grid Ratio, r | Efficiency (%) | Error, εa | GCI |
---|
1 | 912097 | 1.31 | 77.74 | 0.90043 | 1.5896 |
2 | 1192047 | 1.21 | 78.44 | 0.42070 | 1.1502 |
3 | 1438976 | 1.07 | 78.11 | 0.38407 | 3.0851 |
4 | 1546893 | 1.13 | 78.41 | 0.71419 | 3.3582 |
5 | 1740401 | 0.90 | 77.85 | 0.15414 | 1.0281 |
Table 5.
Comparison of experimental and simulation test results of the tubular turbine.
Table 5.
Comparison of experimental and simulation test results of the tubular turbine.
Description | Rotational Speed (rpm) | Head (m) | Flow Rate (m3/s) | Power (kW) | Efficiency (%) |
---|
Experimental | 496 | 13.00 | 0.95 | 98.70 | 79.90 |
Simulation | 500 | 12.97 | 0.97 | 91.45 | 73.43 |
Error (%) | 0.806 | 0.231 | 2.105 | 7.345 | 8.097 |
Table 6.
Performance according to guide vane shape (H = 14.84 m).
Table 6.
Performance according to guide vane shape (H = 14.84 m).
Description | Runner Vane Angle (°) | Guide Vane Angle (°) | Flow Rate (m3/s) | Power (kW) | Efficiency (%) |
---|
Short chord | 19 | 40 | 1.127 | 126.84 | 77.13 |
Long chord | 19 | 40 | 1.091 | 123.47 | 77.69 |
Table 7.
Performance of guide vane attached to the generator side (short chord, H = 14.84 m).
Table 7.
Performance of guide vane attached to the generator side (short chord, H = 14.84 m).
Description | Runner Vane Angle (°) | Guide Vane Angle (°) | Flow Rate (m3/s) | Power (kW) | Efficiency (%) |
---|
Before attachment | 19 | 40 | 1.127 | 126.84 | 77.13 |
After attachment | 19 | 40 | 1.113 | 127.23 | 78.46 |
Table 8.
Performance characteristics according to guide vane shape (short chord, H = 14.84 m).
Table 8.
Performance characteristics according to guide vane shape (short chord, H = 14.84 m).
Description | Runner Vane Angle (°) | Guide Vane Angle (°) | Flow Rate (m3/s) | Power (kW) | Efficiency (%) |
---|
Before change | 19 | 40 | 1.113 | 127.23 | 78.46 |
After change | 19 | 40 | 1.086 | 123.91 | 78.35 |
19 | 42 | 1.067 | 121.06 | 77.95 |
19 | 38 | 1.110 | 126.69 | 78.67 |
19 | 45 | 1.016 | 115.16 | 77.83 |
20 | 40 | 1.118 | 126.52 | 77.71 |
Table 9.
Performance characteristics according to guide vane shape (long chord, H = 14.84 m).
Table 9.
Performance characteristics according to guide vane shape (long chord, H = 14.84 m).
Description | Runner Vane Angle (°) | Guide Vane Angle (°) | Flow Rate (m3/s) | Power (kW) | Efficiency (%) |
---|
Attached short chord | 19 | 38 | 1.110 | 126.69 | 78.67 |
Attached long chord | 19 | 40 | 1.011 | 114.57 | 77.84 |
19 | 38 | 1.043 | 118.80 | 78.24 |
20 | 40 | 1.040 | 117.78 | 77.58 |
20 | 45 | 0.966 | 107.44 | 76.38 |
22 | 40 | 1.104 | 124.22 | 77.78 |
Table 10.
Performance characteristics according to runner vane shape (H = 14.84 m).
Table 10.
Performance characteristics according to runner vane shape (H = 14.84 m).
Description | Runner Vane Angle (°) | Guide Vane Angle (°) | Flow Rate (m3/s) | Water Power (kW) | Power (kW) | Efficiency (%) |
---|
Compact shape | 19 | 40 | 1.011 | 147.20 | 114.57 | 77.84 |
Expanded shape | 19 | 40 | 0.966 | 140.55 | 116.53 | 82.91 |
24 | 40 | 1.101 | 159.96 | 133.43 | 83.41 |
24 | 38 | 1.131 | 164.50 | 135.37 | 82.31 |
Table 11.
Performance characteristics according to runner vane rotation speed (H = 14.84 m, GV-40°).
Table 11.
Performance characteristics according to runner vane rotation speed (H = 14.84 m, GV-40°).
Rotational Speed (rpm) | Runner Vane Angle (°) | Flow Rate (m3/s) | Power (kW) | Efficiency (%) |
---|
850 | 24 | 1.101 | 133.43 | 83.41 |
750 | 24 | 1.046 | 124.46 | 81.77 |
700 | 24 | 1.019 | 119.29 | 80.37 |
650 | 24 | 0.994 | 114.03 | 78.75 |
650 | 23 | 0.975 | 113.08 | 79.61 |
650 | 27 | 1.076 | 123.84 | 79.02 |