Article

Lessons Learned from 10 Years of ANITA Mox for Sidestream Treatment

by
Romain Lemaire
1 and
Magnus Christensson
2,*
1
Veolia Business Support & Performance, 93300 Aubervilliers, France
2
Veolia Water Technologies, AnoxKaldnes, 226 47 Lund, Sweden
*
Author to whom correspondence should be addressed.
Processes 2021, 9(5), 863; https://doi.org/10.3390/pr9050863
Submission received: 8 April 2021 / Revised: 10 May 2021 / Accepted: 12 May 2021 / Published: 14 May 2021
(This article belongs to the Special Issue Anammox-Based Processes for Wastewater Treatment)

Abstract

:
When a wastewater treatment plant (WWTP) uses anaerobic digestion (AD) on its sludge treatment line, the opportunity to install a sidestream deammonification process for the cost-effective removal of the N-rich reject water load generated by the sludge digester should be considered. In this context, the ANITA™ Mox process based on the moving bed biofilm reactor (MBBR) technology has been implemented at more than 30 full-scale facilities over the last 10 years to treat reject water from conventional AD or after thermal hydrolysis process (THP) to reduce the N-load and associated treatment costs on the WWTP. This paper reviews the lessons learned in the implementation of the ANITA™ Mox process at several WWTP in the US, Europe, and Australia.

1. Introduction

As populations grow, it is important for municipal wastewater treatment plants (WWTPs) to identify cost-effective methods to manage total nitrogen (TN) levels and meet their environmental obligations. Untreated reject water from anaerobic digestion leads to 10–20% additional TN and ammonium load to the main treatment process in a WWTP. This leads to extra cost for (i) infrastructure (tank volume, equipment), (ii) chemicals such as external carbon source addition to increase denitrification capacity, and (iii) energy due to higher aeration capacity for nitrification [1]. With infrastructure delivery costs also increasing, there is also a focus on finding the lowest cost solutions for the greatest benefit.
In addition, many utilities are now looking beyond conventional anaerobic digestion (AD) to increase methane production and further reduce the volume of final biosolids and associated costs. Thermal Hydrolysis Process (THP) is one of the processes being considered to achieve these outcomes [2]. THP pre-treatment also allows reducing considerably the size of the downstream digester due to the lower viscosity of hydrolysed sludge. The downside of all these benefits, return sidestream from a THP + AD sludge treatment, can generate up to 30% additional N-load to the WWTP and produce intermediate inhibitory compounds [3,4]. Therefore, a sidestream treatment process installed today for the dedicated treatment of conventional anaerobic digester reject water should consider the possibility that THP may be installed in the future, leading to higher N-load to be treated and a specific process operation strategy to overcome the toxicity of THP.
Sidestream deammonification processes using anaerobic ammonium oxidation (Anammox) bacteria are now widely implemented to treat the N-load generated by the sludge treatment line in a very cost-effective manner. Due to the slow growth rate of anammox bacteria, long sludge ages have to be maintained, making biofilm systems a robust technology to perform deammonification. Ammonium Oxidising Bacteria (AOB) and anammox bacteria are maintained in a biofilm on moving carriers with no risk of biomass wash-out [5]. Moving bed biofilm reactor (MBBR) systems are less sensitive to high total suspended solids (TSS) level surges in the reject water inherent to the operation of dewatering units at all WWTPs, as incoming TSS can simply pass through the MBBR in most cases without impacting the anammox biomass safely retained on the biofilm carrier.
In this context, the ANITA™ Mox technology has been implemented at more than 30 full-scale facilities over the last 10 years to treat reject water from conventional AD or after THP. It is a one-stage MBBR deammonification process where partial nitrification to nitrite (i.e., nitritation) and autotrophic N-removal (i.e., anammox) occur simultaneously within the biofilm [6] (Figure 1). Aerobic and anoxic zones reside adjacent to each other due to the oxygen mass transfer limitation under limited and controlled bulk dissolved oxygen (DO) concentration. AOB oxidise ammonium (NH4) to nitrite (NO2) in the aerobic zone of the biofilm (i.e., outer part), while anammox bacteria located in the anoxic zone of the biofilm (i.e., inner part) consume NO2 produced by AOB together with the residual NH4 (Figure 1). The use of high-surface-area AnoxKTM5 carrier material allows for compact design and simple process operation with maximal biomass retention security [7].
This paper reviews the lessons learned in the implementation of the ANITA™ Mox process at several WWTP in the US and more recently in Australia for conventional AD sidestream treatment using MBBR configuration and in Europe for THP + AD application using the more adapted integrated fixed-film activated sludge (IFAS) configuration. Table 1 summarises the different ANITA Mox case studies that will be presented in more detail in this paper.

2. Lessons Learned from Treating Conventional Reject Water

2.1. James River, VA: 1st ANITA Mox in the US

The Hampton Roads Sanitation District (HRSD) installed the 1st ANITA Mox in the US at its James River Wastewater Treatment Plant treating 76,000 m3/d (76 MLD) in Newport News, VA. An existing pre-aeration tank was retrofitted to install the ANITA Mox process. Centrate design flow is 280 m3/d with a NH4 load of 250 kgN/d at a concentration of 900 mgN/L. The warm centrate temperature after anaerobic digester (30–35 °C based on buffer tank size and tank/pipe insulation) means that no heating device is usually required to keep the optimum design temperature of 30 °C in the ANITA Mox reactor. The process started in December 2013 with 10% of the total media volume supplied with pre-colonised biofilm from an established ANITA Mox located in Malmö, Sweden. This 1st ANITA Mox plant in Sweden was used as a “Biofarm” to provide seed media with pre-colonised Anammox biofilm to reduce the start-up time of new ANITA Mox plants (typically 5–15% of total media volume). Anammox activity was detected on the virgin media 3 months after seeding.
Ref. [8] reported that 4 months after seeding, the ANITA Mox reactor was achieving more than 85% NH4 removal at design load condition (Figure 2). During the 1-month performance test done in May 2014, the maximum NH4 load applied to the system was 375 kgN/d (50% more than design load) and the average NH4 removal rate was 90% (83% TIN = NH4 + NO3 + NO2 removal). The average NH4 level in the outlet was 100 mgN/L.

2.2. South Durham, NC: Most Cost-Effective Solution

The City of Durham, NC in the US completed a comprehensive wastewater master plan that evaluated different treatment techniques for meeting strict total nitrogen limits (TN < 3 mgN/L) at the South Durham Water Reclamation Facility (SDWRF). The city studied mainstream and sidestream treatment alternatives to meet its TN limits considering both capital and operating costs. ANITA Mox was estimated to cost $2.1/kg N-removed, while the most cost-effective mainstream biological nutrient removal (BNR) solution was estimated at $5.9/kg N-removed [9]. Thus, the city selected ANITA Mox to meet its strict effluent nitrogen limits using the most cost-effective solution.
The ANITA Mox design consists of two identical and parallel MBBR reactors that were retrofitted in sludge aeration basins that were no longer in use. Filtrate design flow is 300 m3/d with a NH4 load of 300 kgN/d at a concentration of 1000 mg/L. The minimum design temperature is 24 °C due to the lack of insulation and large buffer tank size. The process started in August 2015 with 7% of seed media coming from the James River plant (Figure 3). The system was treating the full centrate load by Nov 2015 and achieved greater than 80% NH4 removal and 70% TN removal, both exceeding guaranteed values. Hollowed et al. 2018 describes a few imbalance process events that occurred at the plant such as short-term nitrate (NO3) accumulation due to higher activity of Nitrite Oxidising Bacteria (NOB) or NH4 accumulation from uneven feed flow between the two parallel tanks. Each time, these process disturbances were quickly fixed through better process control of the aeration and centrate feed flow to the reactors, demonstrating the robustness of the ANITA Mox system.

2.3. Egan, IL: Robust Performance under Variable Flow

The Metropolitan Water Reclamation District of Greater Chicago (MWRDGC) installed the ANITA Mox system at its Egan Water Reclamation Plant in Schaumburg, IL. Existing, unused dissolved air flotation (DAF) thickening tanks were converted into one equalisation tank and four identical, parallel ANITA Mox reactors. Centrate design flow is 860 m3/d with a NH4 load of 940 kgN/d at a concentration of 1100 mg/L. The minimum design temperature is 27.5 °C without any heating device.
The process started in August 2016 with 10% of seed media coming from the James River plant. Experiences during the startup phase are summarised in [10] and include extended periods (10 months) of limited centrate availability due to maintenance/revamping work on the sludge line and alkalinity limitation. Egan reactors each receive similar flow through gravitational distribution via the weir box. Minor adjustments in aeration setpoints between the reactors are sufficient to keep them operating with similar performance.
As shown in Figure 4, after the 10 months of limited centrate availability, the ANITA Mox reached the design load in less than 3 months. A 90-day performance test was performed from April to June 2018. The average NH4 load during that period was 75% of design load but with periods reaching 120% of design load based on centrate availability. The limited size of the centrate equalisation tank did not allow the process to be fed continuously during weekends when centrifuges were off, meaning that during the weekdays, the load and flow were often higher than design values [11]. Despite this large flow variation, average NH4 and TIN removal efficiency were 89% and 81%, respectively with some fluctuation observed between the low load periods (higher removal efficiency >90%) and the high load periods often exceeding the design load (lower removal efficiency around 80%). Average NH4 levels in the centrate and in the ANITA Mox outlet were 1230 mgN/L and 140 mgN/L, respectively.

2.4. Denver, CO: Largest ANITA Mox to Date

The Metropolitan Water Reclamation District (MWRD) in Denver, CO USA, installed the largest ANITA Mox plant to date at its Robert W. Hite Water Reclamation Facility (850 MLD) by converting an existing return activated sludge (RAS) reaeration basin into two parallel ANITA Mox MBBR reactors (Figure 5). The centrate design flow is 3400 m3/d with a NH4 load of 4000 kgN/d at a concentration of 1200 mgN/L. The process started in August 2017 with 5% of seed media coming from US and Europe ANITA Mox plants. As seen in Figure 6, it took only 13 weeks to reach the full design load, while starting with only 5% of seed media.
Experiences during this startup include instances of loading over design, variable flow, high polymer residual, and high TSS spikes. The ANITA Mox was very resilient to all of these disturbances thanks to the robustness of the MBBR system and its complete anammox biofilm retention feature. The goal of MWRD is to load the ANITA Mox to its maximum capacity (consistently above design load by 20–50%) targeting a residual NH4 level between 200 and 300 mgN/L. It results in a lower NH4 removal efficiency (65–75% instead of >85%) but allows them not to dose any extra alkalinity despite being limited in their centrate. Then, the ANITA Mox outlet is polished in remaining RAS reaeration basins.

2.5. Brisbane: 1st Anammox Plant in Australia

The Anammox journey in Australia began in 2014 for Queensland Urban Utilities (QUU) and Veolia at QUU innovation centre located at Luggage Point WWTP in Brisbane. Starting with only 10 L of homegrown Anammox seed media provided by the University of Queensland, QUU and Veolia decided to carefully grow these precious bacteria, as biomass importation from overseas is not allowed to Australia, in order to have sufficient biomass to perform a 6 m3 pilot trial. After several years of piloting, Urban Utilities decided to move to a full-scale sidestream anammox process for the Luggage point WWTP. The decision was based on the following required outcomes for Urban Utilities:
  • Reduce OPEX cost associated with nitrogen removal in their WWTP (methanol to reach TN < 5 mg/L).
  • Reduce the cost of delivery by retrofitting existing infrastructure.
  • Be a leader in implementation of new technology in Australia with positive environmental outcomes.
ANITA™ Mox technology was selected as the media-based process, since it allowed easy retrofit into existing process tanks, and also, the process had proved itself to be very stable in extreme fluctuation of centrate feed conditions and quality during the pilot trial period: including power outage, feed stoppages, polymer overdose, high TSS in feed.
To proceed with this implementation at full scale, a larger amount of seed media was needed than available in the 6 m3 pilot plant. To grow this seed media, QUU installed a small 12 m3 biofarm tank at their innovation centre in 2017, and Veolia later installed a larger 50 m3 biofarm tank in 2019 (Figure 7). The enrichment process took approximately 8 months to establish the seed required for the full-scale treatment process. In parallel, Urban Utilities and Veolia embarked on the process of upgrading four unused process tanks at the Luggage Point WWTP to accommodate the new full-scale sidestream deammonification process.
At the time of writing this paper (April 2021), the new sidestream tanks have been successfully retrofitted and commissioned with the seed media from the 50 m3 biofarm, treating approximately 60% of the design flow. Once fully operational, the ANITA Mox sidestream process at Luggage point will be treating up to 1000 m3/d of centrate with a design load of 975 kgN/d. Urban Utilities and Veolia will be operating these tanks as a biofarm as well as an integral part of the treatment process at Luggage Point. This means anammox seed in sufficient quantities will be easily available for other Australian Utilities considering ANITA Mox for their own WWTP upgrades.

3. Lessons Learned from Treating THP Centrate

When THP is introduced into the sludge treatment process, not only ammonia and soluble COD concentration increase, but also intermediate inhibitory compounds that typically require dilution of the centrate to maintain high removal performance. For this application, the IFAS configuration of ANITA™ Mox (Figure 8) has proven to be more robust than the MBBR configuration due to the buffering capacity of the heterotrophs and the increased amount of AOB in the mixed liquor suspended solids (MLSS), whereas the anammox bacteria are safely retained on the media [12,13]. Today, there are seven ANITA Mox units treating THP centrate: Växjö (Sweden), Grindsted (Denmark), FiveFords (UK), Toulouse (France) that are in operation, Osberstown (Ireland) under commissioning, and Ljubjlana (Slovenia) and Piscataway (US) that are under construction.

3.1. Växjö (Sweden): 1st Anammox THP Fullscale Plant

In 2011, Sundet WWTP located in Växjö, Sweden, installed the ANITA Mox process for sidestream management. The facility has a capacity of 95,000 population equivalent (PE) with an average daily flow of 20,000 m3/d and discharges to nutrient-sensitive lakes around Växjö. At the time of initial startup, the system was processing filtrate from conventional anaerobically digested biosolids, native to the facility. The ANITA Mox system, operated in the MBBR configuration, was retrofitted within an existing SBR reactor. The existing fine bubble diffusers were retained in the reactor and the tank was filled with 45% of AnoxK™5 media.
In 2014–2015, the facility installed a THP upstream of the existing digesters in anticipation of an increasing solids load to the digesters in the form of source-separated household food waste and an increasing sludge volume from the existing plant. With the addition of THP, the plant is able to handle the increasing amounts of sludge and food waste using the existing digesters without the need for new digesters. In spite of higher strength filtrate, the ANITA Mox system was still able to treat all of the filtrate produced with the addition of dilution water; however, there were concerns regarding the stability of the process and the volume of dilution water being used why it was decided to upgrade to an IFAS configuration. An external stainless-steel settler was installed in May 2018, allowing the process to be operated as an IFAS. At design flows, the overflow velocity of the clarifier is 1.5 m/h. The ANITA Mox system was designed to treat an initial NH4 load of 320 kgN/d, with the ability to treat up to 300 m3/d of filtrate at 1400 mg N/L (corresponding to 430 kgN/d). The system should provide NH4 and TN removal efficiency greater than 75% and 65% respectively.
Prior to THP, the MBBR ANITA Mox was receiving an average NH4 load of 140 kgN/d and the performance of the system was, on average, 90% NH4 and 83% TN removal. The ratio of NO3 produced to NH4 removed was typically less than 11% and averaged 8%, overall (Figure 9).
After the installation of the THP process, and before the conversion of the ANITA Mox from MBBR to IFAS, the filtrate required dilution to minimise the inhibitory effects of recalcitrant COD and N compounds generated by the THP. The average ratio of dilution water to total flow during that period was 40%. The average influent NH4 was 900 mgN/L and the NH4 load was 160 kgN/d. The performance of the MBBR system was 85% NH4 and 77% TN removal (Figure 9).
After converting the ANITA Mox to its IFAS configuration, the NH4 load to the system increased to an average of 200 kgN/d, and the plant was able to treat the filtrate with less dilution water (20% on average), resulting in NH4 concentration up to 1300 mgN/L. Results from operation in the IFAS configuration shows NH4 and TN removal of 89% and 83%, with only 6% NO3 production (Figure 9).

3.2. Wrexham (UK): 1st IFAS ANITA Mox for THP

Welsh Water decided to install a sludge treatment platform next to their FiveFords WWTP in Wrexham, UK. This new THP + AD sludge platform receives sludge from all over the region. To reduce the NH4 load returned to the nearby WWTP, an IFAS ANITA Mox was included in the overall sludge upgrade work by Mott MacDonald Bentley (MMB). The sludge platform is designed to treat 53 tDS/d producing a NH4 load in the final centrate of 850 kgN/d with a design flow of 425 m3/d and a concentration of 2000 mgN/L. The ANITA Mox IFAS system at Wrexham was the 1st deammonification plant built by MMB (Figure 10). The process was initially supposed to be started up using existing conventional AD centrate while the new THP unit was getting constructed and then gradually increase the THP fraction in the centrate. Due to a change of construction planning, the ANITA Mox was started after the THP upgrade works using full-strength THP centrate straight from the beginning. Therefore, the quantity of seed media was increased from 10% originally to a total of 25% with a second addition occurring 3 months after the first one. This was necessary as the change in commissioning plan resulted in the centrate design load being available more rapidly than foreseen initially.
After adjusting the IFAS operation to balance the high AOB activity in the MLSS to the growing but limited Anammox activity on the media, it was observed that the alkalinity of the centrate was often limiting, resulting in unstable and more challenging operation. Therefore, it was decided to better control the NH4 removed and final NH4 concentration in the outlet to avoid being alkalinity limited. The instrumentation for NH4 on-line measurement was changed from ISE sensor to an analyser after filtration (FILTRAX and AMTAX units from HACH) to improve the accuracy of the measurement in this challenging THP matrix. Then, aeration of the ANITA Mox was controlled based on a target NH4 value in the outlet to prevent alkalinity limitation and stabilise the operation. The drops in NH4 removal efficiency from 85% to 80% around Day 380 and then to 75% on Day 440 observed in Figure 11 were the results of action taken to operate at a higher NH4 level in the IFAS to save on alkalinity and avoid dosing caustic to the system.
Despite a longer start-up time to reach full design load, the IFAS ANITA Mox at Wrexham is successfully treating all the THP centrate produced by the new sludge platform (Figure 12). The anammox activity on both the seed and initial virgin media has been monitored during the entire period through ex situ laboratory batch test and microbial analysis (quantitative polymerase chain reaction—qPCR) by Veolia Research and Innovation team in Paris and AnoxKaldnes process experts in Sweden providing robust evidence that the biofilm colonisation by Anammox in the IFAS ANITA Mox process at Wrexham was always progressing in the right direction. This comprehensive technical and scientific support was key to overcome some of the challenges encountered during the start-up.

3.3. Toulouse (France): Largest IFAS ANITA Mox

Toulouse Metropole decided to upgrade the sludge treatment line at the Ginestous WWTP (1M PE). The new sludge line is composed of BioThelysTM THP, two large anaerobic digesters of 6000 m3 each, and a MemGasTM biomethane purification unit to produce 56 GWh/year that will be reinjected into the city natural gas grid. For the cost-effective removal of the NH4 load returned to the WWTP, an IFAS ANITA Mox is treating all the centrate generated by the THP and AD. Figure 13 shows a 3D illustration of the new sludge treatment line with the IFAS ANITA Mox highlighted in red. The new sludge line is still under the final commissioning stage but is already treating all the sludge produced by the plant today, approximately 45 tDS/d for a design load of 73 tDS/d in 2035. The IFAS ANITA Mox is designed to treat a NH4 load of 1800 kgN/d with a centrate flow of 1000 m3/d in 2035. Today, it is already treating all the centrate produced by the THP + digester (approximately 900 m3/d corresponding to 800–1000 kgN/d) despite having been seeded with only 8% of pre-colonised Anammox media.

4. Lessons Learned with Operation Control Strategy

Experiences show that the deammonification systems have some challenges during their start-up phase and their operation. Reported challenges are mainly due to the slow growth rate of the anammox bacteria, the complex interactions between different groups of microorganisms, and these microorganisms being sensitive to inhibition [14]. There is a need for a safe operation strategy to overcome such challenges. Known operation strategies require reliable on-line sensors and acute attention from the operator. When the operation strategy mostly relies on the operator’s attention, it is very likely to have disturbances in operation during the absence of a dedicated operator. Considering the entire operation period and the long start-up phase of such processes, a lot of man-hours are needed for process control.
The control strategy of the ANITA Mox was developed to have not only safe but also optimised operation in a less operator-dependent way. Veolia’s digital offering Hubgrade Performance Plant provides process optimisation and long-term stability in operation. The Hubgrade Performance Plant is a cloud-based holistic service for real-time optimisation of the process performance. This digital solution calculates set points for blowers and feed pumps using operational data from the on-line sensors and algorithms built in the features. This allows adjustment of aeration flow into the reactor and feed flow rate to optimal levels, thus providing a state-of-the-art autopilot to optimize the whole treatment process.
Overall, the ANITA Mox operation with Hubgrade Performance Plant provides an automated real-time performance optimisation, remote monitoring of operation via a user interface, stable optimal conditions 24/7 and maximal utilisation of all the ANITA Mox benefits.
Nitrous oxide (N2O) emissions from sidestream deammonification processes have been often linked to specific operation control strategies employed by the different technologies such as feeding regime (continuous vs. batch), aeration control (continuous vs. intermittent), and substrate concentration gradient in the reactor [15,16]. Ref. [15] reported N2O emission from a full-scale granular sequencing batch reactor (SBR) deammonification unit at Ejby Mølle WWTP in Denmark in the range of 4–8% of incoming N-load under standard intermittent aeration control. The N2O emission was divided by half (2–4% of N-load) when the granular SBR was operated under a new continuous aeration strategy. Similar observation was made by [16] comparing N2O emission of a full-scale sidestream SBR operated in nitrification/denitrification (N/DN) mode at Slottshagen WWTP in Sweden to that of a deammonification MBBR unit replacing the existing SBR for reject water treatment. While the N2O emission of the N/DN SBR was averaging 10% of incoming N-load, it was reduced to an average of 0.1–0.7% of incoming N-load for the deammonification MBBR operated under continuous feed and continuous aeration. The N2O emission measurement campaign at the ANITA Mox MBBR at Växjö was performed in 2012 [6], and average N2O emissions of 0.2–0.8% of incoming N-load were reported with very low N2O emission during stable operation (0.04–0.16%) and higher emission (up to 1%) when the centrate feed was not continuous, triggering the aeration to stop in the reactor until centrate was made available again at the plant. Therefore, N2O emission from MBBR-based ANITA Mox is significantly lower than from other sidestream deammonication systems due to its continuous feed and continuous aeration feature. Operation with the Hubgrade Performance Plant system provides further optimisation of the N2O emission by offering more stable operation in term of feed regime and aeration control.

5. Conclusions

With more than 30 references installed over the last ten years, the Veolia experience with Anammox has been a positive and passionate journey. With consistent good performance for NH4 and TN removal at WWTPs combined with the added benefits of reduced OPEX for the overall WWTP, ANITA Mox has proven itself as a viable, robust, and sustainable process that can be considered for the treatment of reject water from conventional AD or after THP. With biofarms now available in Europe, the US, and Australia, this unique and exciting process can be easily installed at other WWTPs. Daily operation of such anammox systems can be improved through the use of digital advanced control system providing continuous process optimisation and stability during start-up and long-term operation.

Author Contributions

R.L. and M.C. contributed equally to this paper. Conceptualisation, R.L. and M.C.; investigation, R.L. and M.C.; visualisation, R.L.; writing—review and editing, R.L. and M.C. Both authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

The authors would like to thank the following people who helped gathering fullscale data from the different sites: Meg Hollowed for the US based plant, Justin Todhunter for Luggage Point, Anneli Andersson Chan for Växjö, Andrew Cannon for FiveFords.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Barber, W. Thermal hydrolysis for sewage treatment: A critical review. Water Res. 2016, 104, 53–71. [Google Scholar] [CrossRef]
  2. Bilyk, K.; Khunjar, W.; Latimer, R.; Galst, S.; Drummey, T.; Hanna, A.; Wankmuller, D.; Pitt, P. Lessons learned from multiple sidestream deammonification projects. In Proceedings of the WEFTEC 2017, Chicago, IL, ISA, 30 September–4 October 2017. [Google Scholar]
  3. Fidgore, B.; Bowden, G.; Stinson, B.; Wett, B.; Hell, M.; Bailey, W.; Carr, J.; Der Minassian, R.; Murthy, S. Treatment of Dewatering Sidestream from a Thermal Hydrolysis-Mesophilic Anaerobic Digestion Process with a Single-Sludge Deammonification Process. In Proceedings of the WEFTEC 2011, Miami, FL, USA, 15–19 October 2011. [Google Scholar]
  4. Zhang, O.; Vlaeminck SDeBarbadillo, C.; Su, C.; Al-Omari, A.; Wett, B.; Pumpel, T.; Shaw, A.; Chandran, K.; Murthy, S.; De Clippeleir, H. Supernatant organics from anaerobic digestion after thermal hydrolysis cause direct and/or diffusional activity loss for nitritation and anammox. Water Res. 2018, 143, 270–281. [Google Scholar] [CrossRef]
  5. Cema, G. Comparative Study on Different Anammox Systems. Ph.D. Thesis, KTH Stockholm, Stockholm, Sweden, 2009. [Google Scholar]
  6. Christensson, M.; Ekström, S.; Andersson Chan, A.; Le Vaillant, E.; Lemaire, R. Experience from Start-up of the first ANITA Mox plants. Water Sci. Technol. 2013, 67, 2677–2684. [Google Scholar] [CrossRef]
  7. Lemaire, R.; Thesing, G.; Christensson, M.; Zhao, H.; Liviano, I. Experience from Start-Up and Operation of Deammonification MBBR Plants, and Testing of a New Deammonification IFAS Configuration. In Proceedings of the WEFTEC 2013, Chicago, IL, USA, 5–9 October 2013. [Google Scholar]
  8. Klaus, S.; Nifong, A.; Nelson, A.; Rutherford, B.; Baumler, R.; Bott, C. Recommendations and Lessons Learned from the Startup of the First two Fullscale Sidestream Deammonification Processes in North America: DEMON and ANITA mox. In Proceedings of theWEFTEC 2015, Chicago, IL, USA, 26–30 September 2015. [Google Scholar]
  9. Bilyk, K.; Khunjar, W.; Pace, G.; Worley-Morse, T.; Cocker, C.; Lobdell, S.; Taylor, R.; Gasper, B.; Pitt, P. Lessons learned about deammonification from design, startup, and operation of an ANITA Mox system. In Proceedings of the WEF Nutrient Symposium, Fort Lauderdale, FL, USA, 12–14 June 2017. [Google Scholar]
  10. Lai, K.; Hollowed, M.; Qin, C.; Storino, L.; Wawczak, B.; Brand, M.; Thesing, G. Start-up of Sidestream Deammonification at MWRDGC’s John E. Egan Water Reclamation Plant. In Proceedings of the WEFTEC 2017, Chicago, IL, USA, 30 September–4 October 2017. [Google Scholar]
  11. Hollowed, M.; Thesing, G.; Liang, S. Tale of Two Cities: Operation of Sidestream ANITA Mox. In Proceedings of the WEF Nutrient Removal and Recovery Conference, Raleigh, NC, USA, 18–21 June 2018. [Google Scholar]
  12. Lemaire, R.; Veuillet, F.; Bausseron, A.; Chastrusse SMonnier, R.; Christensson, M.; Zhao HThomson, C.; Ochoa, J. ANITA Mox deammonification process for COD-rich and THP reject water. In Proceedings of the WEFTEC 2015, Chicago, IL, USA, 26–30 September 2015. [Google Scholar]
  13. Hollowed, M.; Lemaire, R.; Graveleau, L.; Veuillet, F.; Christensson, M.; Nussbaum, B.; Zhao, H. IFAS ANITA™Mox Deammonification Process for Treating THP Reject Water: From Lab/Pilot Scale Development to Full Scale Implementation. In Proceedings of the WEF Nutrient Removal and Recovery Conference, Minneapolis, MN, USA, 23–25 July 2019. [Google Scholar]
  14. Lackner, S.; Gilbert, M.E.; Vlaeminck, S.E.; Joss, A.; Horn, H.; van Loosdrecht, M.C.M. Full-scale partial nitritation/anammox experiences—An application survey. Water Res. 2014, 55, 292–303. [Google Scholar] [CrossRef]
  15. Uri, N.; Eriksen, S.; Nielsen, P.; Andersen, M.; Hafner, S.; Li, Z.; Chandran, K. Continuous aeration control to reduce N2O emissions in a full-scale sidestream deammonification reactor. In Proceedings of the WEFTEC 2017, Chicago, IL, USA, 30 September–4 October 2017. [Google Scholar]
  16. Kanders, L.; Yang, J.J.; Baresel, C.; Zambrano, J. Full-scale comparison of N2O emissions from SBR N/DN operation versus one-stage deammonification MBBR treating reject water—And optimization with pH set-point. Water Sci. Technol. 2019, 79, 1616–1625. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Biological mechanisms occurring in the biofilm of the AnoxKTM5 carriers of the ANITATM Mox MBBR process.
Figure 1. Biological mechanisms occurring in the biofilm of the AnoxKTM5 carriers of the ANITATM Mox MBBR process.
Processes 09 00863 g001
Figure 2. ANITA Mox start-up performance adapted from [8]. TIN (Total Inorganic Nitrogen) = NH4 + NO3 + NO2.
Figure 2. ANITA Mox start-up performance adapted from [8]. TIN (Total Inorganic Nitrogen) = NH4 + NO3 + NO2.
Processes 09 00863 g002
Figure 3. Photo of AnoxKTM5 carriers 1 year after start-up (left: “seed” carrier, right: “virgin” carrier).
Figure 3. Photo of AnoxKTM5 carriers 1 year after start-up (left: “seed” carrier, right: “virgin” carrier).
Processes 09 00863 g003
Figure 4. NH4 load, NH4, and TIN removal efficiency.
Figure 4. NH4 load, NH4, and TIN removal efficiency.
Processes 09 00863 g004
Figure 5. Photo of the ANITA Mox reactor in Denver retrofitted into an existing RAS reaeration tank.
Figure 5. Photo of the ANITA Mox reactor in Denver retrofitted into an existing RAS reaeration tank.
Processes 09 00863 g005
Figure 6. NH4 load applied and removed (in kgN/d) at Denver since start-up of the ANITA Mox.
Figure 6. NH4 load applied and removed (in kgN/d) at Denver since start-up of the ANITA Mox.
Processes 09 00863 g006
Figure 7. Scale-up journey to grow anammox bacteria locally for 1st ANITA Mox in Australia.
Figure 7. Scale-up journey to grow anammox bacteria locally for 1st ANITA Mox in Australia.
Processes 09 00863 g007
Figure 8. IFAS ANITA Mox configuration.
Figure 8. IFAS ANITA Mox configuration.
Processes 09 00863 g008
Figure 9. NH4 concentration in the inlet and outlet of the ANITA Mox in Växjö.
Figure 9. NH4 concentration in the inlet and outlet of the ANITA Mox in Växjö.
Processes 09 00863 g009
Figure 10. New IFAS ANITA Mox reactor at Wrexham (left: IFAS tank, right: clarifier).
Figure 10. New IFAS ANITA Mox reactor at Wrexham (left: IFAS tank, right: clarifier).
Processes 09 00863 g010
Figure 11. NH4 level in the inlet and outlet of the ANITA Mox at Wrexham and percentage of NH4 removed.
Figure 11. NH4 level in the inlet and outlet of the ANITA Mox at Wrexham and percentage of NH4 removed.
Processes 09 00863 g011
Figure 12. NH4 load applied and removed (kgN/d) at the ANITA Mox in FiveFords.
Figure 12. NH4 load applied and removed (kgN/d) at the ANITA Mox in FiveFords.
Processes 09 00863 g012
Figure 13. Three-dimensional (3D) drawing of the THP + AD sludge treatment extension project in Toulouse and photo of the IFAS ANITA Mox unit.
Figure 13. Three-dimensional (3D) drawing of the THP + AD sludge treatment extension project in Toulouse and photo of the IFAS ANITA Mox unit.
Processes 09 00863 g013
Table 1. ANITA Mox case studies treating conventional AD or THP + AD centrate presented in this paper.
Table 1. ANITA Mox case studies treating conventional AD or THP + AD centrate presented in this paper.
NameFlow WWTP
(MLD)
Type of CentrateDesign Load
(Kgn/D)
Design Flow
(M3/D)
Design NH4 Level
(Mgn/L)
ANITA Mox Config.Start-Up Year
James River (US)76AD250280900MBBR2014
South Durham (US)20AD3003001000MBBR2015
Egan (US)30AD9408601100MBBR2016
Denver (US)850AD400034001200MBBR2017
Luggage Point (AU)130AD9751000975MBBR2021
Växjö (SE)20THP + AD4303001400IFAS2011
FiveFords (UK)26THP + AD *8504252000IFAS2019
Toulouse (FR)160THP + AD180010001800IFAS2020
* FiveFords THP + AD unit is designed to treat external sludge in addition to that produced by the plant itself.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Lemaire, R.; Christensson, M. Lessons Learned from 10 Years of ANITA Mox for Sidestream Treatment. Processes 2021, 9, 863. https://doi.org/10.3390/pr9050863

AMA Style

Lemaire R, Christensson M. Lessons Learned from 10 Years of ANITA Mox for Sidestream Treatment. Processes. 2021; 9(5):863. https://doi.org/10.3390/pr9050863

Chicago/Turabian Style

Lemaire, Romain, and Magnus Christensson. 2021. "Lessons Learned from 10 Years of ANITA Mox for Sidestream Treatment" Processes 9, no. 5: 863. https://doi.org/10.3390/pr9050863

APA Style

Lemaire, R., & Christensson, M. (2021). Lessons Learned from 10 Years of ANITA Mox for Sidestream Treatment. Processes, 9(5), 863. https://doi.org/10.3390/pr9050863

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop