Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases
Abstract
:1. Introduction
2. Materials and Methods
Denture Duplication
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Chen, L.; Li, D.; Zhou, J.; Lin, W.S.; Tan, J. Duplicating complete dentures with conventional and digital methods: Comparisons of trueness and efficiency. Dent. J. 2022, 10, 35. [Google Scholar] [CrossRef]
- Roessler, D.M. Complete denture success for patients and dentists. Int. Dent. J. 2003, 53, 340–345. [Google Scholar] [CrossRef]
- Mijiritsky, E.; Ben Zaken, H.; Shacham, M.; Cinar, I.C.; Tore, C.; Nagy, K.; Ganz, S.D. Variety of surgical guides and protocols for bone reduction prior to implant placement: A narrative review. Int. J. Environ. Res. Public. Health 2021, 18, 2341. [Google Scholar] [CrossRef]
- Haralur, S.B. Clinical strategies for complete denture rehabilitation in a patient with Parkinson disease and reduced neuromuscular control. Case Rep. Dent. 2015, 2015, 352878. [Google Scholar] [CrossRef]
- Chen, Y.; Luo, Z.; Sun, Y.; Zhou, Y.; Han, Z.; Yang, X.; Kang, X.; Lin, J.; Qi, B.; Lin, W.W.; et al. The effect of denture-wearing on physical activity is associated with cognitive impairment in the elderly: A cross-sectional study based on the CHARLS database. Front. Neurosci. 2022, 16, 925398. [Google Scholar] [CrossRef]
- Goodacre, B.J.; Goodacre, C.J.; Baba, N.Z.; Kattadiyil, M.T. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J. Prosthet. Dent. 2016, 116, 249–256. [Google Scholar] [CrossRef]
- Soo, S.; Cheng, A.C. Complete denture copy technique-A practical application. Singapore Dent. J. 2014, 35, 65–70. [Google Scholar] [CrossRef]
- Zafar, M.S. Prosthodontic Applications of Polymethyl Methacrylate (PMMA): An Update. Polymers 2020, 12, 2299. [Google Scholar] [CrossRef]
- Villias, A.; Karkazis, H.; Yannikakis, S.; Theocharopoulos, A.; Sykaras, N.; Polyzois, G. Current status of digital complete dentures technology. Prosthesis 2021, 3, 229–244. [Google Scholar] [CrossRef]
- Lee, S.; Hong, S.J.; Paek, J.; Pae, A.; Kwon, K.R.; Noh, K. Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method. J. Adv. Prosthodont. 2019, 11, 55–64. [Google Scholar] [CrossRef]
- Helal, M.A.; Al-Gazzar, A.E.; Abas, M.; Akhtar, S.; Gad, M.M.; Al-Thobity, A.M. Comparative Effect of Different Surface Treatments on the Shear Bond Strength of Two Types of Artificial Teeth Bonded To Two Types of Denture Base Resins. J. Prosthodont. 2022, 31, 427–433. [Google Scholar] [CrossRef]
- Clark, W.A.; Duqum, I.; Kowalski, B.J. The digitally replicated denture technique: A case report. J. Esthet. Restor. Dent. 2019, 31, 20–25. [Google Scholar] [CrossRef]
- Ammoun, R.; Bencharit, S. Creating a digital duplicate denture file using a desktop scanner and an open-source software program: A dental technique. J. Prosthet. Dent. 2021, 125, 402–406. [Google Scholar] [CrossRef]
- Renne, W.; Revell, G.; Teich, S. The digital denture replication method (DRM): A simplified method to fabricate a complete removable prosthesis. Quintessence Int. 2020, 51, 838–843. [Google Scholar] [CrossRef]
- Takeda, Y.; Lau, J.; Nouh, H.; Hirayama, H. A 3D printing replication technique for fabricating digital dentures. J. Prosthet. Dent. 2020, 124, 251–256. [Google Scholar] [CrossRef]
- Fekri, L.K.; Abdelaziz, M.S. Digital duplication of maxillary complete denture: A dental technique. J. Esthet. Restor. Dent. 2023, 35, 1139–1143. [Google Scholar] [CrossRef]
- Alehaideb, A.; Lin, W.S.; Levon, J.A.; Chu, T.G.; Yang, C.C. Accuracy of digital duplication scanning methods for complete dentures. J. Prosthodont. 2023. early view. [Google Scholar] [CrossRef]
- Zeidan, A.A.; Sherif, A.F.; Baraka, Y.; Abualsaud, R.; Abdelrahim, R.A.; Gad, M.M.; Helal, M.A. Evaluation of the Effect of Different Construction Techniques of CAD-CAM Milled, 3D-Printed, and Polyamide Denture Base Resins on Flexural Strength: An In Vitro Comparative Study. J. Prosthodont. 2023, 32, 77–82. [Google Scholar] [CrossRef]
- Helal, M.A.; Fadl-Alah, A.; Baraka, Y.M.; Gad, M.M.; Emam, A.M. In-vitro comparative evaluation for the surface properties and impact strength of CAD/CAM milled, 3D printed, and polyamide denture base resins. J. Int. Soc. Prev. Community Dent. 2022, 12, 126–131. [Google Scholar] [CrossRef]
- Hsu, C.-Y.; Yang, T.-C.; Wang, T.-M.; Lin, L.D. Effects of fabrication techniques on denture base adaptation: An in vitro study. J. Prosthet. Dent. 2020, 124, 740–747. [Google Scholar] [CrossRef]
- Kalberer, N.; Mehl, A.; Schimmel, M.; Müller, F.; Srinivasan, M. CAD-CAM milled versus rapidly prototyped (3-D-printed) complete dentures: An in vitro evaluation of trueness. J. Prosthet. Dent. 2019, 121, 637–643. [Google Scholar] [CrossRef]
- Bud, E.S.; Bocanet, V.I.; Muntean, M.H.; Vlasa, A.; Bucur, S.M.; Păcurar, M.; Dragomir, B.R.; Olteanu, C.D.; Bud, A. Accuracy of three-dimensional (3d) printed dental digital models generated with three types of resin polymers by extra-oral optical scanning. J. Clin. Med. 2021, 10, 1908. [Google Scholar] [CrossRef]
- Negm, E.E.; Aboutaleb, F.A.; Alam-Eldein, A.M. Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques. J. Prosthodont. 2019, 28, 804–810. [Google Scholar] [CrossRef]
- Lamfon, H.A.; Hamouda, I.M. Maxillary denture flange and occlusal discrepancies of Vertex ThermoSens in comparison with conventional heat-cured denture base materials. J. Biomed. Res. 2019, 33, 139–144. [Google Scholar] [CrossRef]
- Yang, Y.; Yang, Z.; Lin, W.-S.; Chen, L.; Tan, J. Digital duplication and 3d printing for implant overdenture fabrication. J. Prosthodont. 2021, 30, 139–142. [Google Scholar] [CrossRef]
- Adali, U.; Peroz, S.; Schweyen, R.; Hey, J. Replica denture technique: Improvements through the use of CAD-CAM technology. Int. J. Comput. Dent. 2021, 24, 439–448. [Google Scholar]
- Chintalacheruvu, V.K.; Balraj, R.U.; Putchala, L.S.; Pachalla, S. Evaluation of three different processing techniques in the fabrication of complete dentures. J. Int. Soc. Prev. Community Dent. 2017, 7, 18–23. [Google Scholar] [CrossRef]
- Habib, S.R. Replacing existing dentures by copy-denture technique for geriatric patients: A case report. JPDA 2013, 22, 265–269. [Google Scholar]
- AlRumaih, H.S. Clinical applications of intraoral scanning in removable prosthodontics: A literature review. J. Prosthodont. 2021, 30, 747–762. [Google Scholar] [CrossRef]
- Tian, Y.; Chen, C.; Xu, X.; Wang, J.; Hou, X.; Li, K.; Lu, X.; Shi, H.; Lee, E.S.; Jiang, H.B. A Review of 3D printing in dentistry: Technologies, affecting factors, and applications. Scanning 2021, 2021, 9950131. [Google Scholar] [CrossRef]
- Hwangbo, N.K.; Nam, N.E.; Choi, J.H.; Kim, J.E. Effects of the washing time and washing solution on the biocompatibility and mechanical properties of 3D printed dental resin materials. Polymers 2021, 13, 4410. [Google Scholar] [CrossRef]
- Katheng, A.; Kanazawa, M.; Komagamine, Y.; Iwaki, M.; Namano, S.; Minakuchi, S. Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography. J. Adv. Prosthodont. 2022, 14, 45–55. [Google Scholar] [CrossRef]
- Oyamada, Y.; Yonezawa, Y.; Kondo, H. Simple duplication technique of complete denture using an intraoral scanner. J. Prosthodont. 2021, 30, 458–461. [Google Scholar] [CrossRef]
- Abduo, J.; Lyons, K.; Bennamoun, M. Trends in computer-aided manufacturing in prosthodontics: A review of the available streams. Int. J. Dent. 2014, 2014, 783948. [Google Scholar] [CrossRef]
- Artopoulos, A.; Juszczyk, A.S.; Rodriguez, J.M.; Clark, R.K.; Radford, D.R. Three-dimensional processing deformation of three denture base materials. J. Prosthet. Dent. 2013, 110, 481–487. [Google Scholar] [CrossRef]
- Helal, M.A.; Abd Elrahim, R.A.; Zeidan, A.A. Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study. J. Prosthodont. 2023, 32, 11–19. [Google Scholar] [CrossRef]
- Alharbi, N.; Osman, R.B.; Wismeijer, D. Factors influencing the dimensional accuracy of 3d-printed full-coverage dental restorations using stereolithography technology. Int. J. Prosthodont. 2016, 29, 503–510. [Google Scholar] [CrossRef]
- Jeong, Y.G.; Lee, W.S.; Lee, K.B. Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method. J. Adv. Prosthodont. 2018, 10, 245–251. [Google Scholar] [CrossRef]
- Schubert, O.; Edelhoff, D.; Erdelt, K.J.; Nold, E.; Güth, J.F. Accuracy of surface adaptation of complete denture bases fabricated using milling, material jetting, selective laser sintering, digital light processing, and conventional injection molding. Int. J. Comput. Dent. 2022, 25, 151–159. [Google Scholar] [CrossRef]
- Li, D.; Yang, S.T.; Yuan, Q.; Mo, A.C.; Yue, L. Accuracy and retention of denture bases fabricated by injection molding, milling, and three-dimensional printing. Zhonghua Kou Qiang Yi Xue Za Zhi. 2022, 57, 927–931. (In Chinese) [Google Scholar] [CrossRef]
- Einarsdottir, E.R.; Geminiani, A.; Chochlidakis, K.; Feng, C.; Tsigarida, A.; Ercoli, C. Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling. J. Prosthet. Dent. 2020, 124, 116–121. [Google Scholar] [CrossRef] [PubMed]
- Kane, B.; Shah, K.C. In Vitro Analysis of Shear Stress: CAD Milled vs. Printed Denture Base Resins with Bonded Denture Tooth. J. Prosthodont. 2023, 32, 29–37. [Google Scholar] [CrossRef] [PubMed]
- Tzanakakis, E.G.; Pandoleon, P.; Sarafianou, A.; Kontonasaki, E. Adhesion of Conventional, 3D-Printed and Milled Artificial Teeth to Resin Substrates for Complete Dentures: A Narrative Review. Polymers 2023, 15, 2488. [Google Scholar] [CrossRef] [PubMed]
Measurement Points | ANOVA Test | Tukey’s Post Hoc Test | |||||
---|---|---|---|---|---|---|---|
Variable | Mean + SD (mm) | p | Pairwise-Comparison | p | |||
Antero-posterior | A–B | Reference Denture | 1 | (33.07) | 0.000 * | G 1 vs. G 2 | 0.012 |
G1 (AvaDent) | 10 | 33.06 ± 0.11 | G 1 vs. G 3 | 0.000 | |||
G2 (IvoBase) | 10 | 32.88 ± 0.08 | G 1 vs. G 4 | 0.000 | |||
G3 (NextDent) | 10 | 32.70 ± 0.07 | G 1 vs. G 5 | 0.000 | |||
G4 (Harzlab) | 10 | 32.68 ± 0.08 | G 2 vs. G 3 | 0.013 | |||
G5 (iFlext) | 10 | 32.51 ± 0.15 | G 2 vs. G 4 | 0.006 | |||
G 2 vs. G 5 | 0.000 | ||||||
G 3 vs. G 4 | 0.764 | ||||||
G 3 vs. G 5 | 0.010 | ||||||
G 4 vs. G 5 | 0.019 | ||||||
A–C | Reference Denture | 1 | (32.00) | 0.000 * | G 1 vs. G 2 | 0.002 | |
G 1 | 10 | 31.99 ± 0.07 | G 1 vs. G 3 | 0.000 | |||
G 2 | 10 | 31.69 ± 0.09 | G 1 vs. G 4 | 0.000 | |||
G 3 | 10 | 31.30 ± 0.07 | G 1 vs. G 5 | 0.000 | |||
G 4 | 10 | 31.30 ± 0.12 | G 2 vs. G 3 | 0.000 | |||
G 5 | 10 | 29.38 ± 0.22 | G 2 vs. G 4 | 0.000 | |||
G 2 vs. G 5 | 0.000 | ||||||
G 3 vs. G 4 | 0.000 | ||||||
G 3 vs. G 5 | 0.000 | ||||||
G 4 vs. G 5 | 0.000 | ||||||
Medio-lateral | B–C | Reference Denture | 1 | (47.20) | 0.000 * | G 1 vs. G 2 | 0.000 |
G 1 | 10 | 47.09 ± 0.14 | G 1 vs. G 3 | 0.000 | |||
G 2 | 10 | 46.8 ± 0.02 | G 1 vs. G 4 | 0.000 | |||
G 3 | 10 | 46.29 ± 0.04 | G 1 vs. G 5 | 0.000 | |||
G 4 | 10 | 45.89 ± 0.07 | G 2 vs. G 3 | 0.000 | |||
G 5 | 10 | 45.34 ± 0.15 | G 2 vs. G 4 | 0.000 | |||
G 2 vs. G 5 | 0.000 | ||||||
G 3 vs. G 4 | 0.000 |
Denture Base Resins | Mean ± SD Mm | ANOVA Test | Tukey’s Post Hoc Test | ||
---|---|---|---|---|---|
Milled | G 1 | 0.155 ± 0.004 | 0.000 | G 2 | 0.000 |
G 3 | 0.000 | ||||
G 4 | 0.000 | ||||
G 5 | 0.000 | ||||
G 2 | 0.191 ± 0.002 | G 1 | 0.000 | ||
G 3 | 0.000 | ||||
G 4 | 0.000 | ||||
G 5 | 0.000 | ||||
3D Printed | G 3 | 0.236 ± 0.111 | G 1 | 0.000 | |
G 2 | 0.000 | ||||
G 4 | 0.000 | ||||
G 5 | 0.000 | ||||
G 4 | 0.296 ± 0.005 | G 1 | 0.000 | ||
G 2 | 0.000 | ||||
G 3 | 0.000 | ||||
G 5 | 0.000 | ||||
Injected | G 5 | 0.626 ± 0.186 | G 1 | 0.000 | |
G 2 | 0.000 | ||||
G 3 | 0.000 | ||||
G 4 | 0.000 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Emam, A.-N.M.; El-Esawy, A.A.; Alyami, M.H.; Baraka, Y.; Gad, M.M.; Helal, M.A. Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases. Dent. J. 2024, 12, 32. https://doi.org/10.3390/dj12020032
Emam A-NM, El-Esawy AA, Alyami MH, Baraka Y, Gad MM, Helal MA. Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases. Dentistry Journal. 2024; 12(2):32. https://doi.org/10.3390/dj12020032
Chicago/Turabian StyleEmam, Abdel-Naser M., Ahmed Ayman El-Esawy, Mohammed Hamad Alyami, Yasser Baraka, Mohammed M. Gad, and Mohamed Ahmed Helal. 2024. "Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases" Dentistry Journal 12, no. 2: 32. https://doi.org/10.3390/dj12020032
APA StyleEmam, A. -N. M., El-Esawy, A. A., Alyami, M. H., Baraka, Y., Gad, M. M., & Helal, M. A. (2024). Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases. Dentistry Journal, 12(2), 32. https://doi.org/10.3390/dj12020032