Ratio between Height and Thickness of the Buccal Tissues: A Pilot Study on 32 Single Implants
Abstract
:1. Introduction
2. Methods
2.1. Patient Selection
2.2. Surgical and Prosthetic Procedures
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Acknowledgments
Conflicts of Interest
References
- Mangano, F.G.; Mastrangelo, P.; Luongo, F.; Blay, A.; Tunchel, S.; Mangano, C. Aesthetic outcome of immediately restored single implants placed in extraction sockets and healed sites of the anterior maxilla: A retrospective study on 103 patients with 3 years of follow-up. Clin. Oral Implants Res. 2017, 28, 272–282. [Google Scholar] [CrossRef] [PubMed]
- Steigmann, M.; Monje, A.; Chan, H.L.; Wang, H.L. Emergence profile design based on implant position in the esthetic zone. Int. J. Periodontics Restor. Dent. 2014, 34, 559–563. [Google Scholar] [CrossRef] [PubMed]
- Levine, R.A.; Ganeles, J.; Gonzaga, L.; Kan, J.K.; Randel, H.; Evans, C.D.; Chen, S.T. 10 Keys for Successful Esthetic-Zone Single Immediate Implants. Compend. Contin. Educ. Dent. 2017, 38, 248–260. [Google Scholar] [PubMed]
- Abuhussein, H.; Pagni, G.; Rebaudi, A.; Wang, H.L. The effect of thread pattern upon implant osseointegration. Clin. Oral Implants Res. 2010, 21, 129–136. [Google Scholar] [CrossRef]
- Albrektsson, T.; Zarb, G.; Worthington, P.; Eriksson, A.R. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int. J. Oral Maxillofac. Implants 1986, 1, 11–25. [Google Scholar] [PubMed]
- Annibali, S.; Bignozzi, I.; La Monaca, G.; Cristalli, M.P. Usefulness of the aesthetic result as a success criterion for implant therapy: A review. Clin. Implant Dent. Relat Res. 2012, 14, 3–40. [Google Scholar] [CrossRef] [PubMed]
- Fürhauser, R.; Florescu, D.; Benesch, T.; Haas, R.; Mailath, G.; Watzek, G. Evaluation of soft tissue around single-tooth implant crowns: The pink esthetic score. Clin. Oral Implants Res. 2005, 16, 639–644. [Google Scholar] [CrossRef]
- Belser, U.C.; Grütter, L.; Vailati, F.; Bornstein, M.M.; Weber, H.P.; Buser, D. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: A cross-sectional, retrospective study in 45 patients with a 2- to 4-year follow-up using pink and white esthetic scores. J. Periodontol. 2009, 80, 140–151. [Google Scholar] [CrossRef] [PubMed]
- Hof, M.; Umar, N.; Budas, N.; Seemann, R.; Pommer, B.; Zechner, W. Evaluation of implant esthetics using eight objective indices-Comparative analysis of reliability and validity. Clin. Oral Implants Res. 2018, 29, 697–706. [Google Scholar] [CrossRef]
- Mangano, F.G.; Luongo, F.; Picciocchi, G.; Mortellaro, C.; Park, K.B.; Mangano, C. Soft Tissue Stability around Single Implants Inserted to Replace Maxillary Lateral Incisors: A 3D Evaluation. Int. J. Dent. 2016, 2016, 9393219. [Google Scholar] [CrossRef]
- Chappuis, V.; Araujo, M.G.; Buser, D. Clinical relevance of dimensional bone and soft tissue alterations post-extraction in esthetic sites. Periodontol. 2000 2017, 73, 73–83. [Google Scholar] [CrossRef]
- Araújo, M.G.; Lindhe, J. Dimensional ridge alterations following tooth extraction. An experimental study in the dog. J. Clin. Periodontol. 2005, 32, 212–218. [Google Scholar] [CrossRef] [PubMed]
- Araújo, M.G.; Sukekava, F.; Wennström, J.L.; Lindhe, J. Tissue modeling following implant placement in fresh extraction sockets. Clin. Oral Implants Res. 2006, 17, 615–624. [Google Scholar] [CrossRef]
- Covani, U.; Ricci, M.; Bozzolo, G.; Mangano, F.; Zini, A.; Barone, A. Analysis of the pattern of the alveolar ridge remodelling following single tooth extraction. Clin. Oral Implants Res. 2011, 22, 820–825. [Google Scholar] [CrossRef]
- Araújo, M.G.; Wennström, J.L.; Lindhe, J. Modeling of the buccal and lingual bone walls of fresh extraction sites following implant installation. Clin. Oral Implants Res. 2006, 17, 606–614. [Google Scholar] [CrossRef] [PubMed]
- Buser, D.; Martin, W.; Belser, U.C. Optimizing esthetics for implant restorations in the anterior maxilla: Anatomic and surgical considerations. Int. J. Oral Maxillofac. Implants 2004, 19, 43–61. [Google Scholar]
- Fu, J.H.; Lee, A.; Wang, H.L. Influence of tissue biotype on implant esthetics. Int. J. Oral Maxillofac. Implants 2011, 26, 499–508. [Google Scholar] [PubMed]
- Rojo, R.; Prados-Frutos, J.C.; Manchón, Á.; Rodríguez-Molinero, J.; Sammartino, G.; Calvo Guirado, J.L.; Gómez-de Diego, R. Soft Tissue Augmentation Techniques in Implants Placed and Provisionalized Immediately: A Systematic Review. BioMed Res. Int. 2016, 2016, 7374129. [Google Scholar] [CrossRef] [PubMed]
- Viña-Almunia, J.; Candel-Martí, M.E.; Cervera-Ballester, J.; García-Mira, B.; Calvo-Guirado, J.L.; Peñarrocha-Oltra, D.; Peñarrocha-Diago, M. Buccal bone crest dynamics after immediate implant placement and ridge preservation techniques: Review of morphometric studies in animals. Implant Dent. 2013, 22, 155–160. [Google Scholar] [CrossRef] [PubMed]
- Andlin-Sobocki, A.; Bodin, L. Dimensional alterations of the gingiva related to changes of facial/lingual tooth position in permanent anterior teeth of children. A 2-year longitudinal study. J. Clin. Periodontol. 1993, 20, 219–224. [Google Scholar] [CrossRef]
- Wennström, J.L.; Lindhe, J.; Sinclair, F.; Thilander, B. Some periodontal tissue reactions to orthodontic tooth movement in monkeys. J. Clin. Periodontol. 1987, 14, 660–668. [Google Scholar] [CrossRef]
- Bengazi, F.; Wennström, J.L.; Lekholm, U. Recession of the soft tissue margin at oral implants: A 2-year longitudinal prospective study. Clin. Oral Implants Res. 1996, 7, 303–310. [Google Scholar] [CrossRef] [PubMed]
- Wennström, J.L. Mucogingival considerations in orthodontic treatment. Semin. Orthod. 1996, 2, 46–54. [Google Scholar] [CrossRef]
- Nozawa, T.; Enomoto, H.; Tsurumaki, S.; Ito, K. Biologic height-width ratio of the buccal supra-implant mucosa. Eur. J. Esthet. Dent. 2006, 1, 208–214. [Google Scholar]
- Lazzara, R.J.; Porter, S.S. Platform switching: A new concept in implant dentistry for controlling postrestorative crestal bone levels. Int. J. Periodontics Restor. Dent. 2006, 26, 9–17. [Google Scholar]
- Bechara, S.; Kubilius, R.; Veronesi, G.; Pires, J.T.; Shibli, J.A.; Mangano, F.G. Short (6-mm) dental implants versus sinus floor elevation and placement of longer (≥10-mm) dental implants: A randomized controlled trial with a 3-year follow-up. Clin. Oral Implants Res. 2017, 28, 1097–1107. [Google Scholar] [CrossRef]
- Mangano, F.; Raspanti, M.; Maghaireh, H.; Mangano, C. Scanning Electron Microscope (SEM) Evaluation of the Interface between a Nanostructured Calcium-Incorporated Dental Implant Surface and the Human Bone. Materials 2017, 10, 1438. [Google Scholar] [CrossRef] [PubMed]
- Mangano, F.G.; Iezzi, G.; Shibli, J.A.; Pires, J.T.; Luongo, G.; Piattelli, A.; Mangano, C. Early bone formation around immediately loaded implants with nanostructured calcium-incorporated and machined surface: A randomized, controlled histologic and histomorphometric study in the human posterior maxilla. Clin. Oral Investig. 2017, 21, 2603–2611. [Google Scholar] [CrossRef] [PubMed]
- Han, C.H.; Mangano, F.; Mortellaro, C.; Park, K.B. Immediate Loading of Tapered Implants Placed in Postextraction Sockets and Healed Sites. J. Craniofac. Surg. 2016, 27, 1220–1227. [Google Scholar] [CrossRef]
- Elian, N.; Tabourian, G.; Jalbout, Z.N.; Classi, A.; Cho, S.C.; Froum, S.; Tarnow, D.P. Accurate transfer of peri- implant soft tissue emergence profile from the interim crown to the final prosthesis using an emergence profile cast. J. Esthet. Restor. Dent. 2007, 19, 306–314. [Google Scholar] [CrossRef] [PubMed]
- Oates, T.W.; West, J.; Jones, J.; Kaiser, D.; Cochran, D.L. Long-term changes in soft tissue height on the facial surface of dental implants. Implant Dent. 2002, 11, 272–279. [Google Scholar] [CrossRef] [PubMed]
- Juodzbalys, G.; Wang, H.L. Soft and hard tissue assessment of immediate implant placement: A case series. Clin. Oral Implants Res. 2007, 18, 237–243. [Google Scholar] [CrossRef] [PubMed]
- Macedo, J.P.; Pereira, J.; Vahey, B.R.; Henriques, B.; Benfatti, C.A.; Magini, R.S.; López-López, J.; Souza, J.C. Morse t aper dental implants and platform switching: The new paradigm in oral implantology. Eur. J. Dent. 2016, 10, 148–154. [Google Scholar] [PubMed]
- Farronato, D.; Santoro, G.; Canullo, L.; Botticelli, D.; Maiorana, C.; Lang, N.P. Establishment of the epithelial attachment and connective tissue adaptation to implants installed under the concept of “platform switching”: A histologic study in minipigs. Clin. Oral Implants Res. 2012, 23, 90–94. [Google Scholar] [CrossRef] [PubMed]
- Serrano-Sánchez, P.; Calvo-Guirado, J.L.; Manzanera-Pastor, E.; Lorrio-Castro, C.; Bretones-López, P.; Pérez-Llanes, J.A. The influence of platform switching in dental implants. A literature review. Medicina Oral Patología oral y Cirugía Bucal 2011, 16, e400–e405. [Google Scholar] [CrossRef]
- Weng, D.; Nagata, M.J.H.; Bell, M.; Bosco, A.F.; de Melo, L.G.N.; Richter, E.J. Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs. Clin. Oral Implants Res. 2008, 19, 1141–1147. [Google Scholar] [CrossRef] [PubMed]
- Degidi, M.; Iezzi, G.; Scarano, A.; Piattelli, A. Immediately loaded titanium implant with a tissue stabilizing/mantaining design (‘beyond platform switch’) retrieved from man after 4 weeks: A histological and histomorphometrical evaluation. A case report. Clin. Oral Implants Res. 2008, 19, 276–282. [Google Scholar] [CrossRef] [PubMed]
- Schmitt, C.M.; Nogueira-Filho, G.; Tenenbaum, H.C.; Lai, J.Y.; Brito, C.; Döring, H.; Nonhoff, J. Performance of conical abutment (Morse Taper) connection implants: A systematic review. J. Biomed. Mater. Res. A 2014, 102, 552–574. [Google Scholar] [CrossRef]
- Zipprich, H.; Weigl, P.; Lange, B.; Lauer, H.C. Micromovements at the implant–abutment interface: Measurement, causes, and consequences. Implantologie 2007, 15, 31–46. [Google Scholar]
- Gehrke, S.A.; Delgado-Ruiz, R.A.; Prados Frutos, J.C.; Prados-Privado, M.; Dedavid, B.A.; Granero Marín, J.M.; Calvo Guirado, J.L. Misfit of Three Different Implant-Abutment Connections Before and After Cyclic Load Application: An In Vitro Study. Int. J. Oral Maxillofac. Implants 2017, 32, 822–829. [Google Scholar] [CrossRef]
- Scarano, A.; Valbonetti, L.; Degidi, M.; Pecci, R.; Piattelli, A.; de Oliveira, P.S.; Perrotti, V. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography. Implant Dent. 2016, 25, 656–662. [Google Scholar] [CrossRef] [PubMed]
- Liu, Y.; Wang, J. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck. Arch. Oral Biol. 2017, 83, 153–160. [Google Scholar] [CrossRef] [PubMed]
- Marković, A.; Calvo-Guirado, J.L.; Lazić, Z.; Gómez-Moreno, G.; Ćalasan, D.; Guardia, J.; Čolic, S.; Aguilar-Salvatierra, A.; Gačić, B.; Delgado-Ruiz, R.; et al. Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study. Clin. Implant Dent. Relat. Res. 2013, 15, 341–349. [Google Scholar] [CrossRef] [PubMed]
- Mangano, F.; Gandolfi, A.; Luongo, G.; Logozzo, S. Intraoral scanners in dentistry: A review of the current literature. BMC Oral Health 2017, 17, 149. [Google Scholar] [CrossRef] [PubMed]
- Imburgia, M.; Logozzo, S.; Hauschild, U.; Veronesi, G.; Mangano, C.; Mangano, F.G. Accuracy of four intraoral scanners in oral implantology: A comparative in vitro study. BMC Oral Health 2017, 17, 92. [Google Scholar] [CrossRef] [PubMed]
Patient Number | Implant Number | Implant Position | Implant Diameter | Mucosal Height (MH) | Mucosal Width (MT) | Height/Width Ratio (MH/MT) |
---|---|---|---|---|---|---|
1 | 1 | 36 | 4 mm | 4.5 mm | 5.0 mm | 0.90 |
2 | 2 | 16 | 6 mm | 4 mm | 3.0 mm | 1.33 |
2 | 3 | 35 | 7 mm | 5 mm | 5.0 mm | 1.00 |
2 | 4 | 36 | 8 mm | 5 mm | 4.0 mm | 1.25 |
2 | 5 | 46 | 9 mm | 4 mm | 4.0 mm | 1.00 |
3 | 6 | 14 | 4.5 mm | 3 mm | 2.0 mm | 1.50 |
4 | 7 | 47 | 4.5 mm | 3 mm | 3.0 mm | 1.00 |
5 | 8 | 26 | 3.5 mm | 3 mm | 2.0 mm | 1.50 |
5 | 9 | 45 | 3.5 mm | 3 mm | 1.0 mm | 3.00 |
5 | 10 | 16 | 4.5 mm | 2 mm | 1.0 mm | 2.00 |
6 | 11 | 36 | 4 mm | 4 mm | 5.0 mm | 0.80 |
7 | 12 | 47 | 6 mm | 3 mm | 4.0 mm | 0.75 |
8 | 13 | 13 | 4 mm | 3 mm | 1.5 mm | 2.00 |
8 | 14 | 11 | 4.5 mm | 3 mm | 1.5 mm | 2.00 |
9 | 15 | 47 | 4.5 mm | 3 mm | 4.0 mm | 0.75 |
10 | 16 | 27 | 6 mm | 3 mm | 5.0 mm | 0.60 |
10 | 17 | 24 | 4 mm | 3 mm | 4.0 mm | 0.75 |
10 | 18 | 25 | 4 mm | 3 mm | 5.0 mm | 0.60 |
11 | 19 | 47 | 4 mm | 3.8 mm | 3.0 mm | 1.26 |
11 | 20 | 35 | 4 mm | 7 mm | 6.0 mm | 1.16 |
11 | 21 | 37 | 6 mm | 7 mm | 6.0 mm | 1.16 |
12 | 22 | 45 | 4 mm | 3.5 mm | 3.0 mm | 1.16 |
12 | 23 | 46 | 4 mm | 3.5 mm | 3.5 mm | 1.00 |
13 | 24 | 27 | 4.5 mm | 3 mm | 2.0 mm | 1.50 |
14 | 25 | 35 | 4 mm | 3 mm | 1.5 mm | 2.00 |
15 | 26 | 25 | 3.75 mm | 3 mm | 4.0 mm | 0.75 |
16 | 27 | 47 | 5.5 mm | 1 mm | 2.0 mm | 0.50 |
17 | 28 | 24 | 4.5 mm | 3 mm | 2.0 mm | 1.50 |
18 | 29 | 37 | 5.5 mm | 1 mm | 2.5 mm | 0.40 |
19 | 30 | 37 | 8.5 mm | 2.5 mm | 3.0 mm | 0.83 |
20 | 31 | 14 | 3.5 mm | 4.5 mm | 5.0 mm | 0.90 |
20 | 32 | 26 | 5 mm | 3 mm | 2.0 mm | 1.50 |
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Farronato, D.; Manfredini, M.; Mangano, F.; Goffredo, G.; Colombo, M.; Pasini, P.; Orsina, A.; Farronato, M. Ratio between Height and Thickness of the Buccal Tissues: A Pilot Study on 32 Single Implants. Dent. J. 2019, 7, 40. https://doi.org/10.3390/dj7020040
Farronato D, Manfredini M, Mangano F, Goffredo G, Colombo M, Pasini P, Orsina A, Farronato M. Ratio between Height and Thickness of the Buccal Tissues: A Pilot Study on 32 Single Implants. Dentistry Journal. 2019; 7(2):40. https://doi.org/10.3390/dj7020040
Chicago/Turabian StyleFarronato, Davide, Mattia Manfredini, Francesco Mangano, Giada Goffredo, Marco Colombo, Pietro Pasini, Andrea Orsina, and Marco Farronato. 2019. "Ratio between Height and Thickness of the Buccal Tissues: A Pilot Study on 32 Single Implants" Dentistry Journal 7, no. 2: 40. https://doi.org/10.3390/dj7020040
APA StyleFarronato, D., Manfredini, M., Mangano, F., Goffredo, G., Colombo, M., Pasini, P., Orsina, A., & Farronato, M. (2019). Ratio between Height and Thickness of the Buccal Tissues: A Pilot Study on 32 Single Implants. Dentistry Journal, 7(2), 40. https://doi.org/10.3390/dj7020040