Impact of Silicone Oil Removal on Macular Perfusion
Abstract
:1. Introduction
2. Materials and Methods
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Feng, X.; Li, C.; Zheng, Q.; Qian, X.G.; Shao, W.; Li, Y.; Li, W.; Yin, L.; Wang, Y.; Gao, Q. Risk of silicone oil as vitreous tamponade in pars plana vitrectomy: A systematic review and meta-analysis. Retina 2017, 37, 1989–2000. [Google Scholar] [CrossRef] [PubMed]
- Pichi, F.; Hay, S.; Abboud, E.B. Inner retinal toxicity due to silicone oil: A case series and review of the literature. Int. Ophthalmol. 2020, 40, 2413–2422. [Google Scholar] [CrossRef] [PubMed]
- Van Bussel, E.M.; van der Valk, R.; Bijlsma, W.R.; La Heij, E.C. Impact of duration of macula-off retinal detachment on visual outcome: A systematic review and meta-analysis of literature. Retina 2014, 34, 1917–1925. [Google Scholar] [CrossRef] [Green Version]
- Rabina, G.; Azem, N.; Barequet, D.; Barak, A.; Loewenstein, A.; Schwartz, S. Silicone oil tamponade effect on macular layer thickness and visual acuity. Retina 2020, 40, 998–1004. [Google Scholar] [CrossRef]
- Ghanbari, H.; Kianersi, F.; Jamshidi Madad, A.; Dehghani, A.; Rahimi, A.; Feizi, A.; Naderi Beni, A. The effect of silicone oil tamponade on retinal layers and choroidal thickness in patients with rhegmatogenous retinal detachment: A systematic review and meta-analysis. Int. J. Retin. Vitr. 2021, 7, 76. [Google Scholar] [CrossRef]
- Xiang, W.; Wei, Y.; Chi, W.; Zhang, Z.; Zhong, L.; Liu, R.; Zhang, S. Effect of silicone oil on macular capillary vessel density and thickness. Exp. Ther. Med. 2020, 19, 729–734. [Google Scholar] [CrossRef] [Green Version]
- Effert, R.; Wolf, S.; Arend, O.; Schulte, K.; Reim, M. Retinal hemodynamics after pars plana vitrectomy with silicone oil tamponade. Ger. J. Ophthalmol. 1994, 3, 65–67. [Google Scholar]
- Kubicka-Trzaska, A.; Kobylarz, J.; Romanowska-Dixon, B. Macular microcirculation blood flow after pars plana vitrectomy with silicone oil tamponade. Klin. Ocz. 2011, 113, 146–148. [Google Scholar]
- Spaide, R.F.; Fujimoto, J.G.; Waheed, N.K.; Sadda, S.R.; Staurenghi, G. Optical coherence tomography angiography. Prog. Retin. Eye Res. 2018, 64, 1–55. [Google Scholar] [CrossRef] [PubMed]
- Rommel, F.; Siegfried, F.; Kurz, M.; Brinkmann, M.P.; Rothe, M.; Rudolf, M.; Grisanti, S.; Ranjbar, M. Impact of correct anatomical slab segmentation on foveal avascular zone measurements by optical coherence tomography angiography in healthy adults. J. Curr. Ophthalmol. 2018, 30, 156–160. [Google Scholar] [CrossRef]
- Rommel, F.; Rothe, M.; Kurz, M.; Prasuhn, M.; Grisanti, S.; Ranjbar, M. Evaluating diurnal variations in retinal perfusion using optical coherence tomography angiography. Int. J. Retin. Vitr. 2020, 6, 22. [Google Scholar] [CrossRef] [PubMed]
- Rommel, F.; Siegfried, F.; Sochurek, J.A.M.; Rothe, M.; Brinkmann, M.P.; Kurz, M.; Prasuhn, M.; Grisanti, S.; Ranjbar, M. Mapping diurnal variations in choroidal sublayer perfusion in patients with idiopathic epiretinal membrane: An optical coherence tomography angiography study. Int. J. Retin. Vitr. 2019, 5, 12. [Google Scholar] [CrossRef] [PubMed]
- Otsu, N. Threshold selection method from gray-level histograms. IEEE Trans. Syst. Man. Cybern. 1979, SMC-9, 62–66. [Google Scholar] [CrossRef] [Green Version]
- Fang, W.; Zhai, J.; Mao, J.-B.; Li, H.-D.; Qian, Z.-B.; Chen, C.-Q.; Xu, J.-H.; Shen, L.-J.; Chen, Y.-Q. A decrease in macular microvascular perfusion after retinal detachment repair with silicone oil. Int. J. Ophthalmol. 2021, 14, 875–880. [Google Scholar] [CrossRef]
- Roohipoor, R.; Tayebi, F.; Riazi-Esfahani, H.; Khodabandeh, A.; Karkhaneh, R.; Davoudi, S.; Khurshid, G.S.; Momenaei, B.; Ebrahimiadib, N.; Modjtahedi, B.S. Optical coherence tomography angiography changes in macula-off rhegmatogenous retinal detachments repaired with silicone oil. Int. Ophthalmol. 2020, 40, 3295–3302. [Google Scholar] [CrossRef]
- Lee, J.Y.; Kim, J.Y.; Lee, S.-Y.; Jeong, J.H.; Lee, E.K. Foveal microvascular structures in eyes with silicone oil tamponade for rhegmatogenous retinal detachment: A swept-source optical coherence tomography angiography study. Sci. Rep. 2020, 10, 2555. [Google Scholar] [CrossRef]
- Bayraktar, Z.; Pehlivanoglu, S.; Hagverdiyeva, S.; Albayrak, S.; Karakaya, M.; Bayraktar, Ş. Longitudinal evaluation of retinal thickness and OCTA parameters before and following silicone oil removal in eyes with macula-on and macula-off retinal detachments. Int. Ophthalmol. 2022, 42, 1963–1973. [Google Scholar] [CrossRef]
- Mirza, E.; Şatırtav, G.; Oltulu, R.; Kerimoğlu, H.; Gündüz, M.K. Subfoveal choroidal thickness change following pars plana vitrectomy with silicone oil endotamponade for rhegmatogenous retinal detachment. Int. Ophthalmol. 2019, 39, 1717–1722. [Google Scholar] [CrossRef]
- Nickla, D.L.; Wallman, J. The multifunctional choroid. Prog. Retin. Eye Res. 2010, 29, 144–168. [Google Scholar] [CrossRef] [Green Version]
- Corvi, F.; Su, L.; Sadda, S.R. Evaluation of the inner choroid using OCT angiography. Eye 2021, 35, 110–120. [Google Scholar] [CrossRef]
- Hirata, N.; Iwase, T.; Kobayashi, M.; Yamamoto, K.; Ra, E.; Terasaki, H. Correlation between preoperative factors and final visual acuity after successful rhegmatogenous retinal reattachment. Sci. Rep. 2019, 9, 3217. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Rhatigan, M.; McElnea, E.; Murtagh, P.; Stephenson, K.; Harris, E.; Connell, P.; Keegan, D. Final anatomic and visual outcomes appear independent of duration of silicone oil intraocular tamponade in complex retinal detachment surgery. Int. J. Ophthalmol. 2018, 11, 83–88. [Google Scholar] [CrossRef] [PubMed]
Parameter | Mean |
---|---|
Gender (male/female), n (%) | 12/7 (63.2/36.8) |
Age (years) | 62.3 ± 9.65 |
Duration of oil tamponade (weeks) | 10.0 ± 2.7 |
Laterality (right/left), n (%) | 9/10 (47.37/52.63) |
Initial status macula (on/off), n (%) | 6/13 (31.6/68.4) |
Parameter | Baseline | 4 Weeks | p-Value |
---|---|---|---|
BCVA (logMAR) | 0.5 (0.2; 1.3) | 0.4 (0.0; 1.0) | <0.0001 (Wilcoxon) |
CRT (µm) | 243 ± 40.8 | 263 ± 32.1 | 0.0047 |
TMV (mm3) | 9.8 (8.9; 11.9) | 10.2 (9.4; 12.2) | <0.0001 (Wilcoxon) |
SFCT (µm) | 276 ± 89.6 | 284 ± 102 | 0.434 |
FRP (%) | 26.51 ± 5.2 | 27.39 ± 6.7 | 0.596 |
CCP (%) | 45.09 ± 3.0 | 45.8 ± 2.9 | 0.0013 |
SLP (%) | 59.19 ± 2.4 | 57.72 ± 3.6 | 0.034 |
HLP (%) | 62.37 ± 6.3 | 60.53 ± 4.8 | 0.0402 |
Parameter | Duration | on/off | BCVA | CRT | SFCT | FRP | CCP | HLP | SLP | |
---|---|---|---|---|---|---|---|---|---|---|
duration | CC | 1 | −0.656 | −0.199 | 0.316 | −0.091 | −0.039 | −0.201 | −0.053 | 0.572 |
p | 0 | 0.002 | 0.415 | 0.188 | 0.711 | 0.874 | 0.410 | 0.828 | 0.011 | |
on/off | CC | −0.656 | 1 | 0.513 | −0.085 | −0.059 | 0.316 | −0.070 | 0.104 | −0.351 |
p | 0.002 | 0 | 0.046 | 0.731 | 0.809 | 0.187 | 0.775 | 0.671 | 0.140 | |
BCVA | CC | −0.199 | 0.014 | 1 | −0.410 | 0.279 | −0.153 | −0.288 | −0.048 | 0.212 |
p | 0.415 | 0.956 | 0 | 0.081 | 0.247 | 0.531 | 0.231 | 0.847 | 0.384 | |
CRT | CC | 0.316 | −0.085 | −0.410 | 1 | −0.081 | 0.339 | 0.108 | −0.275 | 0.074 |
p | 0.188 | 0.731 | 0.081 | 0 | 0.741 | 0.156 | 0.660 | 0.255 | 0.762 | |
SFCT | CC | −0.091 | −0.059 | 0.279 | −0.081 | 1 | −0.239 | 0.148 | 0.098 | 0.022 |
p | 0.711 | 0.809 | 0.247 | 0.741 | 0 | 0.324 | 0.546 | 0.690 | 0.930 | |
FRP | CC | −0.039 | 0.316 | −0.153 | 0.339 | −0.239 | 1 | −0.221 | −0.183 | 0.084 |
p | 0.874 | 0.187 | 0.531 | 0.156 | 0.324 | 0 | 0.363 | 0.454 | 0.731 | |
CCP | CC | −0.201 | −0.070 | −0.288 | 0.108 | 0.148 | −0.221 | 1 | −0.013 | −0.433 |
p | 0.410 | 0.775 | 0.231 | 0.660 | 0.546 | 0.363 | 0 | 0.958 | 0.064 | |
HLP | CC | −0.053 | 0.104 | −0.048 | −0.275 | 0.098 | −0.183 | −0.013 | 1 | 0.377 |
p | 0.828 | 0.671 | 0.847 | 0.255 | 0.690 | 0.454 | 0.958 | 0 | 0.111 | |
SLP | CC | 0.572 | −0.351 | 0.212 | 0.074 | 0.022 | 0.084 | −0.433 | 0.377 | 1 |
p | 0.011 | 0.140 | 0.384 | 0.762 | 0.930 | 0.731 | 0.064 | 0.111 | 0 |
Parameter | Duration | on/off | BCVA | CRT | SFCT | FRP | CCP | HLP | SLP | |
---|---|---|---|---|---|---|---|---|---|---|
duration | CC | 1 | −0.656 | −0.334 | 0.276 | −0.072 | −0.372 | −0.118 | 0.221 | 0.440 |
p | 0 | 0.002 | 0.163 | 0.252 | 0.769 | 0.117 | 0.632 | 0.362 | 0.059 | |
on/off | CC | −0.656 | 1 | 0.467 | −0.024 | 0.070 | 0.381 | −0.084 | 0.000 | −0.257 |
p | 0.002 | 0 | 0.044 | 0.921 | 0.775 | 0.108 | 0.732 | 1.000 | 0.289 | |
BCVA | CC | −0.334 | 0.467 | 1 | −0.386 | 0.042 | 0.112 | −0.389 | −0.024 | −0.252 |
p | 0.163 | 0.044 | 0 | 0.102 | 0.864 | 0.647 | 0.100 | 0.921 | 0.298 | |
CRT | CC | 0.276 | −0.024 | −0.386 | 1 | −0.345 | −0.080 | 0.330 | 0.187 | 0.247 |
p | 0.252 | 0.921 | 0.102 | 0 | 0.148 | 0.744 | 0.167 | 0.444 | 0.308 | |
SFCT | CC | −0.072 | 0.070 | 0.042 | −0.345 | 1 | −0.086 | −0.048 | 0.142 | 0.027 |
p | 0.769 | 0.775 | 0.864 | 0.148 | 0 | 0.726 | 0.844 | 0.561 | 0.912 | |
FRP | CC | −0.372 | 0.381 | 0.112 | −0.080 | −0.086 | 1 | 0.003 | 0.126 | −0.144 |
p | 0.117 | 0.108 | 0.647 | 0.744 | 0.726 | 0 | 0.990 | 0.608 | 0.556 | |
CCP | CC | −0.118 | −0.084 | −0.389 | 0.330 | −0.048 | 0.003 | 1 | −0.074 | −0.308 |
p | 0.632 | 0.732 | 0.100 | 0.167 | 0.844 | 0.990 | 0 | 0.764 | 0.200 | |
HLP | CC | 0.221 | 0.000 | −0.024 | 0.187 | 0.142 | 0.126 | −0.074 | 1 | 0.231 |
p | 0.362 | 1.000 | 0.921 | 0.444 | 0.561 | 0.608 | 0.764 | 0 | 0.341 | |
SLP | CC | 0.440 | −0.257 | −0.252 | 0.247 | 0.027 | −0.144 | −0.308 | 0.231 | 1 |
p | 0.059 | 0.289 | 0.298 | 0.308 | 0.912 | 0.556 | 0.200 | 0.341 | 0 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Prasuhn, M.; Rommel, F.; Mohi, A.; Grisanti, S.; Ranjbar, M. Impact of Silicone Oil Removal on Macular Perfusion. Tomography 2022, 8, 1735-1741. https://doi.org/10.3390/tomography8040146
Prasuhn M, Rommel F, Mohi A, Grisanti S, Ranjbar M. Impact of Silicone Oil Removal on Macular Perfusion. Tomography. 2022; 8(4):1735-1741. https://doi.org/10.3390/tomography8040146
Chicago/Turabian StylePrasuhn, Michelle, Felix Rommel, Armin Mohi, Salvatore Grisanti, and Mahdy Ranjbar. 2022. "Impact of Silicone Oil Removal on Macular Perfusion" Tomography 8, no. 4: 1735-1741. https://doi.org/10.3390/tomography8040146
APA StylePrasuhn, M., Rommel, F., Mohi, A., Grisanti, S., & Ranjbar, M. (2022). Impact of Silicone Oil Removal on Macular Perfusion. Tomography, 8(4), 1735-1741. https://doi.org/10.3390/tomography8040146