Knitted Coil for Inductive Plethysmography †
Abstract
:1. Introduction
2. Materials and Methods
3. Results
4. Conclusions
Funding
Conflicts of Interest
References
- Konno, K.; Mead, J. Measurement of the separate volume changes of rib cage and abdomen during breathing. J. Appl. Physiol. 1967, 22, 407–422. [Google Scholar] [CrossRef] [PubMed]
- Cohm, M.A.; Fac, A.S.V.; Broudy, M.; Birch, S.; Watson, H.; Atkins, N.; Davis, B.; Stott, F.D.; Sackner, M.A. The respiratory inductive plethysmograph a new non-invasive monitor of respiration. Bulletin Europeen de Physiopathologie Respiratoire 1982, 18, 643–658. [Google Scholar]
- Fiorillo, A.S.; Critello, C.D.; Pullano, S.A. Theory, technology and applications of piezoresistive sensors: A review. Sens. Actuators A 2018, 281, 156–175. [Google Scholar] [CrossRef]
- Catrysse, M.; Puers, R.; Hertleer, C.; Van Langenhove, L.; van Egmond, H.; Matthys, D. Towards the integration of textile sensors in a wireless monitoring suit. Sens. Actuators A 2004, 114, 302–311. [Google Scholar] [CrossRef]
- Fobelets, K.; Thielemans, K.; Mathivanan, A.; Papavassiliou, C. Characterisation of knitted coils for e-textiles. IEE Sens. J. 2019, 19, 7835–7840. [Google Scholar] [CrossRef]
- Dengler, R. Self inductance of a wire loop as a curve integral. Adv. Electromagn. 2016, 5, 1–8. [Google Scholar] [CrossRef]
- Miller, H.C.; Behrle, F.C. Changing patterns of respiration in newborn infants. Pediatrics 1953, 12, 141–150. [Google Scholar] [CrossRef] [PubMed]
ΔL/ΔD (μH/mm) | Rib | Garter | Stockinette |
---|---|---|---|
Viscose 3.5 mm | 0.064 | 0.068 | 0.081 |
Cotton 3 mm | 0.059 | 0.062 | |
Cotton 7.5 mm | 0.053 | 0.053 | |
Viscose 3.5 mm 1 | 0.072 | 0.084 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2019 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Fobelets, K. Knitted Coil for Inductive Plethysmography. Proceedings 2019, 32, 2. https://doi.org/10.3390/proceedings2019032002
Fobelets K. Knitted Coil for Inductive Plethysmography. Proceedings. 2019; 32(1):2. https://doi.org/10.3390/proceedings2019032002
Chicago/Turabian StyleFobelets, Kristel. 2019. "Knitted Coil for Inductive Plethysmography" Proceedings 32, no. 1: 2. https://doi.org/10.3390/proceedings2019032002
APA StyleFobelets, K. (2019). Knitted Coil for Inductive Plethysmography. Proceedings, 32(1), 2. https://doi.org/10.3390/proceedings2019032002