Abstract

Selectivity Enhancement of an Acetone-Monitoring SPR Sensor: Theoretical Evaluation †

by
Gabriel B. M. Fernandes
1,
Villeneve O. Soares
2,
Jefferson L. B. Marques
1 and
Cleumar S. Moreira
2,*
1
Electrical and Electronic Engineering Department, Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis 88040-900, Brazil
2
Electrical Engineering Department, Federal Institute of Paraiba, João Pessoa 58015-435, Brazil
*
Author to whom correspondence should be addressed.
Presented at the XXXV EUROSENSORS Conference, Lecce, Italy, 10–13 September 2023.
Proceedings 2024, 97(1), 134; https://doi.org/10.3390/proceedings2024097134
Published: 1 April 2024
(This article belongs to the Proceedings of XXXV EUROSENSORS Conference)

Abstract

:
A numerical investigation of a sensor for acetone monitoring using surface plasmon resonance (SPR) is proposed. We evaluate the effects of polyaniline (PANI), graphene, or chitosan acting as a chemisorption binding layer for the selective sensing of acetone. Our findings suggest that these materials present suitable responses when applied as an overlayer to the sensor. Their thicknesses, however, should be maintained close to a monolayer level to preserve performance.

1. Introduction

Acetone is a volatile organic compound that has been the subject of attention in human exhaled breath applications, working as a biomarker for metabolic changes in individuals affected by some diseases, like diabetes [1]. However, the heterogeneity of compounds present in the exhaled breath causes acetone detection to become a challenge. Research in the area aims to find materials to interface this specific analyte with sensor structures. The pursued objective is to detect acetone molecules while avoiding other compounds. The purpose of this paper is to provide an analysis of the materials that have been tested for their chemisorption properties concerning acetone but were not thoroughly applied in conjunction with SPR instrumentation.

2. Materials and Methods

For the numerical analysis, we used a Kretschmann–Raether setup. The calculations were conducted based on the Fresnel equations. Firstly, we simulated and chose parameters for the optimal substrate and metal layers considering the refractive index of acetone. Gold (Au) or silver (Ag) were evaluated for the metal layer. The analyte (acetone) was simulated as a bulk of 150 nm. We simulated our target molecule as if it were contained in an aqueous matrix of breath condensate. Our initial sensor used polycarbonate with a fixed thickness of 3 mm for the optical substrate. Finally, the wavelengths were set to 800 nm for gold and 662 nm for silver. The SPR curve parameters achieved by this initial setup are written in the two first lines of Table 1. The objective was to compare bare-gold- and bare-silver-based SPR sensors to the configurations with the addition of the acetone-binding materials.

3. Discussion

The results are shown in Table 1. Silver achieved the best performance among the metals. Although silver is susceptible to oxidation [2], the added affinity layers may serve as protection against such an effect. Based on the best result, we plotted the SPR signal of the silver-based sensor as a function of the affinity layer thickness, as shown in Figure 1. The most significant repercussion due to the use of PANI was an increase in the minimum reflectance at resonance (MRR) for both metals. This impact was proportional to the thickness of the PANI layer. For silver and gold, the average increase in the MRR was 0.22 and 0.17 per nm of PANI, respectively. The changes in the full width at half maximum (FWHM) and the resonance angle (RA) were slight. Graphene, in turn, caused an increase in the MRR but in conjunction with a displacement of the resonance angle to the right. Finally, using chitosan did not cause modifications to the MRR or FWHM but only a displacement of the resonance angle to the right. In this sense, chitosan is the best-performing acetone affinity layer. For all affinity layers, their thicknesses should be maintained as close to their monolayer levels as possible. As their thicknesses increased, degradations in the SPR curve also increased. The use of chitosan, PANI, and graphene is promising, according to our results. Derived from these preliminary results, the experimental setup of an exhaled breath condensed detector is under development.

Author Contributions

Conceptualization, methodology, validation, writing—review and editing, supervision: J.L.B.M. and C.S.M.; software, investigation, writing—original draft preparation, visualization: G.B.M.F. and V.O.S. All authors have read and agreed to the published version of the manuscript.

Funding

This study was financed by Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) and Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The original contributions presented in the study are included in the article; further inquiries can be directed to the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Ratiu, I.A.; Ligor, T.; Bocos-Bintintan, V.; Mayhew, C.A.; Buszewski, B. Volatile organic compounds in exhaled breath as fingerprints of lung cancer, asthma and copd. J. Clin. Med. 2020, 10, 32. [Google Scholar] [CrossRef] [PubMed]
  2. Kapoor, V.; Sharma, N.K. Effect of oxide layer on the performance of silver based fiber optic surface plasmon resonance sensor. Opt. Quantum Electron. 2022, 54, 475. [Google Scholar] [CrossRef]
Figure 1. SPR curves for silver-based sensor as a function of affinity layer thickness.
Figure 1. SPR curves for silver-based sensor as a function of affinity layer thickness.
Proceedings 97 00134 g001
Table 1. Results for sensor layer simulations.
Table 1. Results for sensor layer simulations.
Layers Thickness FHWM MRR RA
Bare gold51 nm0.865<0.00163.5°
Bare silver57 nm0.406<0.00163.7°
Gold/chitosan1 nm (chitosan)0.865<0.00163.58°
Gold/graphene1 nm (graphene)0.9150.0863.98°
Gold/PANI1 nm (PANI)0.8810.1763.05°
Silver/chitosan1 nm (chitosan)0.406<0.00163.82°
Silver/graphene1 nm (graphene)0.4370.2764.30°
Silver/PANI1 nm (PANI)0.4360.2263.49°
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Fernandes, G.B.M.; Soares, V.O.; Marques, J.L.B.; Moreira, C.S. Selectivity Enhancement of an Acetone-Monitoring SPR Sensor: Theoretical Evaluation. Proceedings 2024, 97, 134. https://doi.org/10.3390/proceedings2024097134

AMA Style

Fernandes GBM, Soares VO, Marques JLB, Moreira CS. Selectivity Enhancement of an Acetone-Monitoring SPR Sensor: Theoretical Evaluation. Proceedings. 2024; 97(1):134. https://doi.org/10.3390/proceedings2024097134

Chicago/Turabian Style

Fernandes, Gabriel B. M., Villeneve O. Soares, Jefferson L. B. Marques, and Cleumar S. Moreira. 2024. "Selectivity Enhancement of an Acetone-Monitoring SPR Sensor: Theoretical Evaluation" Proceedings 97, no. 1: 134. https://doi.org/10.3390/proceedings2024097134

APA Style

Fernandes, G. B. M., Soares, V. O., Marques, J. L. B., & Moreira, C. S. (2024). Selectivity Enhancement of an Acetone-Monitoring SPR Sensor: Theoretical Evaluation. Proceedings, 97(1), 134. https://doi.org/10.3390/proceedings2024097134

Article Metrics

Back to TopTop