Doped Polythiophene Chiral Electrodes as Electrochemical Biosensors

School of Natural Sciences, Laurentian University, Sudbury, ON P3E 2C6, Canada
Electrochem 2021, 2(4), 677-688; https://doi.org/10.3390/electrochem2040042
Submission received: 11 November 2021 / Revised: 14 December 2021 / Accepted: 15 December 2021 / Published: 20 December 2021
(This article belongs to the Special Issue Surface Modification by Conductive Materials)

Abstract

:
π-conducting materials such as chiral polythiophenes exhibit excellent electrochemical stability in doped and undoped states on electrode surfaces (chiral electrodes), which help tune their physical and electronic properties for a wide range of uses. To overcome the limitations of traditional surface immobilization methods, an alternative pathway for the detection of organic and bioorganic targets using chiral electrodes has been developed. Moreover, chiral electrodes have the ability to carry functionalities, which helps the immobilization and recognition of bioorganic molecules. In this review, we describe the use of polythiophenes for the design of chiral electrodes and their applications as electrochemical biosensors.

Graphical Abstract

1. Introduction

π-conducting materials have emerged as excellent tools for detection of organic and bioorganic molecules, due to their stability and reversible electroactive responses [1,2,3,4]. The use of π-conducting materials will help overcome some of the limitations found in common methods used to modify conducting surfaces via thiols [5,6,7] or diazonium salts [8,9,10]. Moreover, their ability to amplify electrochemical signals yields the detection of low concentrations of analytes and selectively distinguishes between enantiomers. As an example, several polyaniline-based enzymatic glucose biosensors have been developed by immobilization of glucose oxidase. In addition to its high electrical conductivity and biocompatibility, polyaniline participates in electron transfer reactions allowing a facile detection of electrochemical signals resulting from the enzymatic reactions [11]. The design of other DNA electrochemical biosensors with a low limit of detection (LOD) based on conducting materials such as polypyrrole have been reported [12,13,14].
Owing to the presence of stereocenters on polymer backbone, chiral electrodes play an important role in several fields including biochemistry, biology and pharmacy [15,16,17]. The combination of biological activities with the electrochemical methods helps the differentiation of amino acid enantiomers, which may lead to the design of chiral voltammetric biosensors [18].
To the best of our knowledge, the first chiral electrode based on chiral polythiophenes was described in 1988 [19]. Chiral monothiophene monomers substituted in position 3 by either R(−) (1-R) and or S(+) (1-S) phenylbutanol were prepared and oxidized via electrochemical oxidation on platinum (Pt) electrode in nitrobenzene to form chiral electrode poly1-Pt. (Scheme 1). Both chiral electrodes (poly1-R-Pt and poly1-S-Pt) have shown stereoselectivity toward chiral doping anions.
Recently, chiral electrodes based on chiral-doped polythiophenes have been found to be very efficient as spin filters at room temperature [20], which may be useful for the design of organic spin-OLED devices. Furthermore, inherently chiral electroactive electrodes display excellent chiro-optical and enantioselective properties allowing the detection of a variety of biomolecules.
Several chiral-polypyrrole modified electrodes have prepared by electropolymerization either of chiral pyrrole monomers [21,22,23] or pyrrole derivatives in the presence of chiral dopants [24,25,26,27]. Similar strategies have been employed for the preparation of chiral-polyaniline modified electrodes [28,29,30].
Polythiophenes are one important class of conjugated conducting materials that exhibit excellent stability at both states, reversible electrochemical responses, high conductivity and the chemistry of their precursors is well established [31,32,33,34].
Chiral electrodes based on polythiophenes can be prepared by electropolymerization of (i) either thiophene monomers bearing stereocenter at position 3 or (ii) thiophene monomers in the presence of chiral doping counter anions using cyclic voltammetry (CV). Scheme 2 displays the representation of electrochemical biosensors including the deposition of chiral polythiophenes on electrode surfaces and the recognition of selected biomolecules.
Herein, we describe the design of chiral electrodes using specific thiophene derivatives and their applications as electrochemical biosensors for the detection of biomolecules in the last decade.

2. Electropolymerization

Although several chemical polymerization methods such as cross coupling reaction [35] or oxidation using FeCl3 [36] have been used to prepare polythiophene polymers, electrochemical oxidation beyond the oxidation potential of thiophene monomers on electrode surface is the method commonly used to deposit doped polythiophenes on electrode surfaces, which allows the convenient characterization of electrochemical and optical properties of the deposited films [37,38,39]. The electropolymerization of thiophene derivatives following an ECE mechanism [40,41,42] is outlined in Scheme 3. The initiation via electron transfer reaction forms a thiophene radical cation, which dimerizes after removal of two protons. The dimer will undergo similar reactions to form a trimer. The reaction chain will continue until the formation of doped polythiophenes at the surface of the electrode.
In addition to low cost, electrochemical methods display various advantages such as easy deposition/characterization of films on electrode surfaces, facile detection of target biomolecules and rapid screening results. Several monothiophenes and terthiophenes (Scheme 4) bearing chiral centers such as d-alanine (Ala) and d-leucine (Leu) have been prepared in excellent yields [43,44].
Due to the high oxidation potential of amino acid (AA) functionalized monothiophenes, their electropolymerization of Pt electrode were unsuccessful. On the other hand, AA functionalized terthiophenes were successfully oxidized on Pt electrode via repeated cycling CV scans.
Figure 1A shows the electropolymerization CV scans of terthiophene bearing Ala (2) in acetonitrile (ACN). The increase of the peak current confirms the successful deposition of the corresponding doped polyterthiophenes to form a chiral electrode poly2-Pt.
In cyclic voltammetry, the examination of the relationship between the peak current with the scan rate can help to distinguish between the nature of electron transfers occurring at the surface of the electrode. For an electron transfer process controlled by diffusion species, the peak current varies linearly with the square root of a scan rate as described by the Randles−Sevcik equation (Equation (2)). On the other hand, when the electron transfer occurs via surface-adsorbed species, the peak current varies linearly with the scan rate Equation (1).
In a free monomer solution, the peak current ip (Figure 1B) observed for the chiral electrodes varies linearly [45,46] with the scan rate Equation (1), which indicates a surface bound species, whereas the peak current varies linearly [45,46] with square root of the scan rate Equation (2) for the diffusing redox species.
i p = n 2 F 2 4 R T ϑ A Γ
i p = 0.446 n F A C 0 ( n F ϑ D 0 R T ) 1 2
Υ (V s−1): scan rate; n: number of electrons; A (cm2): electrode surface area; Do (cm2 s−1): diffusion coefficient; C0 (mol cm−3): concentration of the analyte; Γ (mol cm−2): surface coverage.
Additionally, the peak current the chiral electrode poly2-Pt remains constant over 100 CV scans confirming the excellent stability of the chiral electrode, which is the key step in the successful detection of organic and bioorganic molecules.

3. Chiral Electrodes Based on Polythiophenes

Chirality has been introduced on conducting polythiophene backbones by electropolymerization of chiral precursors. Chiral electrodes based on poly3-Pt and poly4-Pt have been prepared by electropolymerization of 3 and 4 on Pt electrodes, respectively. Poly3-Pt and poly4-Pt are very stable and display excellent adhesive properties. The oxidation potential of these chiral electrodes was found to be between 0.40–0.50 V vs. Fc+/Fc. In order to examine the sensing ability of the biosensor, the capacitive current of the chiral-poly4-Pt has been measured in the absence and presence of AA such as Ala and Leu [47]. Figure 2A shows the differences in the capacitive currents of chiral-poly4-Pt observed after addition of 1 mM of free LeuOMe. The capacitive current decreased by 30% after 30 min. Thus, the reduction of the capacitive current is due to the formation of hydrogen bonds between the free LeuOMe and the chiral-poly4-Pt layers yielding a change in the concentration of the supporting electrolyte at the interface. Moreover, the formation of the hydrogen bonds at the interface between the carboxylic acid in poly4-Pt and LeuOMe has been confirmed by 1H NMR for the monomer 4 and free LeuOMe as depicted in Figure 2C. The chemical shift of N–H (amide) group changed from 8.35 ppm to 8.50 ppm in terthiophene 4 after addition of 1 equivalent of LeuOMe and the coupling constant of the doublet (amide proton) of 4 increased from 7 Hz to 8 Hz. After 30 min, the capacitive currents of poly3-Pt remain constant after addition of 1 mM of LeuOMe (Figure 2B, control experiment), which validates the formation of hydrogen bonds on the surface of poly4-Pt.
In another study, l-Leu functionalized polyEDOT (poly5) have been synthesized in a similar fashion of poly4-Pt [48]. It was found that the chiral center was responsible for the helical structure of the poly5 backbone, and enhances the electrochemical and optical stabilities of the deposited polymer on the surface of the electrode, which is crucial for the design of chiral recognition and optical devices. Similar results have been reported for chiral polyEDOT derivatives (Scheme 5) [49].
A chiral electrode biosensor based on Ala functionalized polyEDOT for the detection of phenyl alanine and 3,4-dihydroxyphenylalanine (DOPA) have been designed by deposition on glassy carbon electrode (GCE) of poly6 [50] and poly7-R(-S) [51], respectively. CV technique was not sensitive enough to detect DOPA enantiomers by poly7-R(-S) modified GCEs. However, differential pulse voltammetry (DPV) was very effective to distinguish between d-DOPA and l-DOPA in contact with poly7-R-GCE and poly7-S-GCE as shown in Figure 3. It was found that the enantiomers d-DOPA and l-DOPA have affinities with poly7-R-GCE and poly7-S-GCE chiral electrodes, respectively. These results were consistent with results reported elsewhere [52,53,54].
Using this approach poly8-S-GCE and poly8-R-GCE chiral electrodes have been used to construct electrochemical sensors that distinguish between d-/l-DOPA, d-/l-tryptophan, and (R)-/(S)-propranolol enantiomers [55]. The mechanism of the chiral detection of these enantiomers involves the formation of hydrogen bonds between the chiral surfaces and the free DOPA (Scheme 6A), which was similar to the chiral electrode based on poly4-Pt. Moreover, the electron transfers resulting from the oxidation of hydroquinone in DOPA to quinone (Scheme 6B) amplify the electrochemical signal and thus facilitate the enantiomeric detection.
An electrochemical sensor similar to natural enzyme using histidine (His), serine (Ser) and glutamic acid (Glu) functionalized polythiophene acetate acid has been employed for the detection of organophosphorus pesticides (OPs) [56]. The coexistence of three AAs on polythiophene surfaces is due to their high catalytic activity and rate of conversion for the hydrolysis of organophosphorus pesticides. Polythiophene acetate has been prepared using classical organic chemistry reaction and deposited on GCE by drop-coating with the help of 5% Nafion as a conducting adhesive binder. The three AA-polythiophenes modified GCE act as an artificial enzyme to catalyze the hydrolysis of organophosphorus pesticides yielding p-nitrophenol, which was further oxidized to form nitroquinone as depicted in Scheme 7. The electron/proton transfers resulting from the conversion of hydroquinone to quinone at the interface of the modified electrode/solution were measured using the square wave voltammetry (SWV), which is more sensitive than CV for the detection organophosphorus pesticides.
The AA functionalized polythiophene modified GCE has been tested for the detection of organophosphorus pesticides such as methyl paraoxon, ethyl paraoxon and methyl parathion. Figure 4 shows the current generated from the oxidation of p-nitrophenol to quinone measured by SWV at 1 V/s of a scan rate at an optimized pH of 5. Moreover, linear curves have been observed and the LOD was found to be lower than the value reported elsewhere [57].
Another approach to introduce chirality on polythiophenes via molecularly imprinted polymers (MIPs) has been reported [58]. MIPs were deposited onto Au QCM (quartz crystal microbalance) electrode surface via CV scans in ACN of terthiophene carboxylic acid in the presence of (−)-norephedrine (Figure 5a). Figure 5b displays the frequency changes observed during the electropolymerization process from doped to undoped polyterthiophenes. In order to confirm the successful incorporation of the chiral motifs by polyterthiophene films, MIPs have been characterized by XPS technique, which shows binding energy features of polyterthiophenes (strong sulfur 2p doublet between 163 and 166 eV) and of (−)-norepherdrine motifs (nitrogen 2s peak between 399 and 403 eV).
After characterization of the (−)-norepherdrine nanostructured MIP surface, the MIP-QCM sensor has been tested for the distinction between (−)-norephedrine (1R, 2S) and its diastereomer (+)-norephedrine (1S, 2S). A change in the frequency response of the (−)-norepherdrine imprinted MIP QCM sensor in contact with (−)-norephedrine has been observed in Figure 6a. However, no significant change of the frequency of the MIP QCM sensor in contact with the antagonist (+)-norepherdrine has been noticed. Similar tendency has been perceived with less frequency response for of (+)-norepherdrine nanostructured MIP sensor in contact with (+)-norepherdrine.
Moreover, the frequency response of the nanostructured MIP-QCM sensor follows a linear response with the concentration of the target norephedrine. Other polypyrrole-MIPs based on MOF-5 derived porous carbon nanotube and Prussian blue nanocube sensors have been used to distinguish between cysteine enantiomers [59].
Using nanoparticles, another method has been developed to introduce chirality on polythiophene surfaces as shown in Figure 7 (left) [60]. After deposition of polythiophenes on GCE via electropolymerization process, MnO2 nanoparticles have also been deposited following a similar procedure described for polyEDOT using KMnO4 [61] to form MnO2-NPs/PolyTh/GCE surface. Then, the d-amino acid oxidase (DAAO) and hemoglobin (Hb) were immobilized on the surface via electrostatic interactions to form DAAO-Hb/MnO2-NPs/PolyTh/GCE sensor. Redox peaks of dopamine (anodic peak at 0.17 V and cathodic peak at 0.11 V) have been observed on DAAO-Hb/MnO2-NPs/PolyTh/GCE sensor (Figure 7 right), but these peaks are absent in other surfaces certifying the excellent selectivity of this sensor toward the detection of dopamine motifs.
Dopamine enantiomers have been differentiated by second-derivative linear sweep voltammetry (SDLSV) using MnO2/nitrogen-doped graphene nanocomposites sensor [62]. In this method, the LOD was found to be 0.039 µM whereas the LOD was found to be 40 nM using DAAO-Hb/MnO2 NPs/PTh/GCE sensor, which validates the importance of polythiophenes for amplifying the sensitivity of electrochemical signals to lower limits of detection.

4. Concluding Remarks

Efforts have been made to design chiral electrodes for the detection of a variety of biomolecules. Taking advantage of the well-established electrochemical properties of polythiophenes, the facile use and low cost of electrochemical methods such as CV and DPV, distinction between enantiomers has been made possible by amplifying the electrochemical signals. Table 1 summarizes a few electrochemical biosensors using polythiophene chiral electrodes.
Chiral electrodes based on polythiophenes exhibit similar LOD observed for chiral -polypyrroles and -polyanilines modified electodes. However, they present better LOD than traditional chiral electrodes, which may be explained by the amplification of the electrical signal resulting from the conducting materials and the diminution of the signal noise.
Chiral electrode sensors are very effective and can be used as an alternative to traditional methods utilized to modify conducting surfaces and detect biomolecules. However, the design of chiral electrodes using new chiral polythiophenes that are very stable on the surface of the electrodes and chiro-selective toward target are important challenges for successful electrochemical biosensors.

Funding

This research received no external funding.

Institutional Review Board Statement

Not Applicable.

Informed Consent Statement

Not Applicable.

Data Availability Statement

Not Applicable.

Acknowledgments

We thank Laurentian University.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Terán-Alcocer, A.; Bravo-Plascencia, F.; Cevallos-Morillo, C.; Palma-Cando, A. Electrochemical sensors based on conducting polymers for the aqueous detection of biologically relevant molecules. Nanomaterials 2021, 11, 252. [Google Scholar] [CrossRef] [PubMed]
  2. Arnaboldi, S.; Grecchi, S.; Magni, M.; Mussini, P. Electroactive chiral oligo- and polymer layers for electrochemical enantiorecognition. Curr. Opin. Electrochem. 2018, 7, 188–199. [Google Scholar] [CrossRef]
  3. Chahma, M.; Gilroy, J.B.; Hicks, R.G. Linear and branched electroactive polymers based on ethylenedioxythiophene–triarylamine conjugates. J. Mater. Chem. 2007, 17, 4768–4771. [Google Scholar] [CrossRef]
  4. Ibanez, J.G.; Rincon, M.E.; Gutierrez-Granados, S.; Chahma, M.; Jaramillo-Quintero, O.A.; Frontana-Uribe, B.A. Conducting polymers in the fields of energy, environmental remediation, and chemical–chiral sensors. Chem. Rev. 2018, 118, 4731–4816. [Google Scholar]
  5. Mandler, D. Chiral self-assembled monolayers in electrochemistry. Curr. Opin. Electrochem. 2018, 7, 42–47. [Google Scholar] [CrossRef]
  6. Chahma, M.; Lee, J.S.; Kraatz, H.-B. Fc-ssDNA conjugate: Electrochemical properties in a borate buffer and adsorption on gold electrode surfaces. J. Electroanal. Chem. 2004, 567, 283–287. [Google Scholar] [CrossRef]
  7. Vericat, C.; Vela, M.E.; Benitez, G.; Carro, P.; Salvarezza, R.C. Self-assembled monolayers of thiols and dithiols on gold: New challenges for a well-known system. Chem. Soc. Rev. 2010, 39, 1805–1834. [Google Scholar] [CrossRef] [PubMed]
  8. Combellas, C.; Kanoufi, F.; Pinson, J.; Podvorica, F.I. Sterically hindered diazonium salts for the grafting of a monolayer on metals. J. Am. Chem. Soc. 2008, 130, 8576–8577. [Google Scholar] [CrossRef]
  9. Adenier, A.; Combellas, C.; Kanoufi, F.; Pinson, J.; Podvorica, F.I. Formation of polyphenylene films on metal electrodes by electrochemical reduction of benzenediazonium salts. Chem. Mater. 2006, 18, 2021–2029. [Google Scholar] [CrossRef]
  10. Assresahegn, B.D.; Brousse, T.; Bélanger, D. Advances on the use of diazonium chemistry for functionalization of materials used in energy storage systems. Carbon 2015, 92, 362–381. [Google Scholar] [CrossRef]
  11. Lai, J.; Yi, Y.; Zhu, P.; Shen, J.; Wu, K.; Zhang, L.; Liu, J. Polyaniline-based glucose biosensor: A review. J. Electroanal. Chem. 2016, 782, 138–153. [Google Scholar] [CrossRef]
  12. Thompson, L.A.; Kowalik, J.; Josowicz, M.; Janata, J. Label-free DNA hybridization probe based on a conducting polymer. J. Am. Chem. Soc. 2003, 125, 324–325. [Google Scholar] [CrossRef] [PubMed]
  13. Lakard, B. Electrochemical biosensors based on conducting polymers: A review. Appl. Sci. 2020, 10, 6614. [Google Scholar] [CrossRef]
  14. Saheb, A.; Patterson, S.; Josowicz, M. Probing for DNA methylation with a voltammetric DNA detector. Analyst 2014, 139, 786–792. [Google Scholar] [CrossRef] [Green Version]
  15. Arnaboldi, S.; Magni, M.; Mussini, P.R. Enantioselective selectors for chiral electrochemistry and electroanalysis: Stereogenic elements and enantioselection performance. Curr. Opin. Electrochem. 2018, 8, 60–72. [Google Scholar] [CrossRef]
  16. Kane-Maguire, L.A.P.; Wallace, G.G. Chiral conducting polymers. Chem. Soc. Rev. 2010, 39, 2545–2576. [Google Scholar] [CrossRef]
  17. Vacek, J.; Zadny, J.; Storch, J.; Hrbac, J. Chiral electrochemistry: Anodic deposition of enantiopure helical molecules. ChemPlusChem 2020, 85, 1954–1958. [Google Scholar] [CrossRef] [PubMed]
  18. Trojanowicz, M. Enantioselective electrochemical sensors and biosensors: A mini-review. Electrochem. Commun. 2014, 38, 47–52. [Google Scholar] [CrossRef]
  19. Lemaire, M.; Delabouglise, D.; Garreau, R.; Guy, A.; Roncali, J. Enantioselective chiral poly(thiophenes). Chem. Commun. 1988, 10, 658–661. [Google Scholar] [CrossRef]
  20. Mondal, P.C.; Kantor-Uriel, N.; Mathew, S.P.; Tassinari, F.; Fontanesi, C. Chiral conductive polymers as spin filters. Adv. Mater. 2015, 27, 1924–1927. [Google Scholar] [CrossRef]
  21. Salmón, M.; Bidan, G. Chiral polypyrroles from optically active pyrrole monomers. J. Electrochem. Soc. 1985, 132, 1897–1899. [Google Scholar] [CrossRef]
  22. Ramos, J.C.; Dias, J.M.M.; Souto-Maior, R.M.; Ribeiro, A.S.; Tonholo, J.; Barbier, V.; Penelle, J.; Navarro, M. Synthesis and characterization of poly[(R)-(−) and (S)-(+)-3-(1′-pyrrolyl)propyl-N-(3″,5″-dinitrobenzoyl)-α-phenylglycinate]s as chiral oligomers of pyrrole. Synth. Met. 2010, 160, 1920–1924. [Google Scholar] [CrossRef]
  23. Takano, N.; Seki, C. Preparation of chiral polypyrrole film-coated electrode incorporating palladium metal and asymmetric hydrogenation of α-keto esters. Electrochemistry 2006, 74, 596–598. [Google Scholar] [CrossRef]
  24. Deore, B.; Yakabe, H.; Shiigi, H.; Nagaok, T. Enantioselective uptake of amino acids using an electromodulated column packed with carbon fibres modified with overoxidised polypyrrole. Analyst 2002, 127, 935–939. [Google Scholar] [CrossRef] [PubMed]
  25. Syritski, V.; Reut, J.; Menaker, A.; Gyurcsányi, R.E.; Öpik, A. Electrosynthesized molecularly imprinted polypyrrole films for enantioselective recognition of l-aspartic acid. Electrochim. Acta 2008, 53, 2729–2736. [Google Scholar] [CrossRef]
  26. Yang, J.; Yu, Y.; Wu, D.; Tao, Y.; Deng, L.; Kong, Y. Coinduction of a chiral microenvironment in polypyrrole by overoxidation and camphorsulfonic acid for electrochemical chirality sensing. Anal. Chem. 2018, 90, 9551–9558. [Google Scholar] [CrossRef]
  27. Zhao, Q.; Yang, J.; Zhang, J.; Wu, D.; Tao, Y.; Kong, Y. Single-template molecularly imprinted chiral sensor for simultaneous recognition of alanine and tyrosine enantiomers. Anal. Chem. 2019, 91, 12546–12552. [Google Scholar] [CrossRef] [PubMed]
  28. Basozabal, I.; Gómez-Caballero, A.; Unceta, N.; Goicolea, M.A.; Barrio, R.J. Voltammetric sensors with chiral recognition capability: The use of a chiral inducing agent in polyaniline electrochemical synthesis for the specific recognition of the enantiomers of the pesticide dinoseb. Electrochim. Acta 2011, 58, 729–735. [Google Scholar] [CrossRef]
  29. He, S.; Shang, X.; Lu, W.; Tian, Y.; Xu, Z.; Zhang, W. Electrochemical enantioselective sensor for effective recognition of tryptophan isomers based on chiral polyaniline twisted nanoribbon. Anal. Chim. Acta 2021, 1147, 155–164. [Google Scholar] [CrossRef]
  30. Feng, Z.; Li, M.; Yan, Y.; Jihai, T.; Xiao, L.; Wei, Q. Several novel and effective methods for chiral polyaniline to recognize the configuration of alanine. Tetrahedron Asymmetry 2012, 23, 411–414. [Google Scholar] [CrossRef]
  31. Tourillon, G.; Garnier, F. Stability of conducting polythiophene and derivatives. J. Electrochem. Soc. 1983, 130, 2042–2044. [Google Scholar] [CrossRef]
  32. Joergensen, M.; Norrman, K.; Gevorgyan, S.A.; Tromholt, T.; Andreasen, B.; Krebs, F.C. Stability of Polymer Solar Cells. Adv. Mater. 2012, 24, 580–612. [Google Scholar] [CrossRef] [PubMed]
  33. So, R.C.; Carreon-Asok, A.C. Molecular design, synthetic strategies, and applications of cationic polythiophenes. Chem. Rev. 2019, 119, 11442–11509. [Google Scholar] [CrossRef]
  34. Kaloni, T.P.; Giesbrecht, P.K.; Schreckenbach, G.; Freund, M.S. Polythiophene: From fundamental perspectives to applications. Chem. Mater. 2017, 29, 10248–10283. [Google Scholar] [CrossRef]
  35. Yamamoto, T.; Koizumi, T.A. Synthesis of π-conjugated polymers bearing electronic and optical functionalities by organometallic polycondensations and their chemical properties. Polymer 2007, 48, 5449–5472. [Google Scholar] [CrossRef] [Green Version]
  36. Nilsson, K.P.R.; Johan, D.; Olsson, J.D.; Konradsson, P.; Inganas, O. Enantiomeric substituents determine the chirality of luminescent conjugated polythiophenes. Macromolecules 2004, 37, 6316–6321. [Google Scholar] [CrossRef]
  37. Chahma, M.; Myles, D.J.T.; Hicks, R.G. Synthesis and characterization of a conducting organomain group polymer, poly[bis((3,4-ethylenedioxy)-2-thienyl) sulfide]:  A heteroaromatic relative of poly(p-phenylene sulfide). Macromolecules 2004, 37, 2010–2012. [Google Scholar] [CrossRef]
  38. Roncali, J. Conjugated poly (thiophenes): Synthesis, functionalization, and applications. Chem. Rev. 1992, 92, 711–738. [Google Scholar] [CrossRef]
  39. Groenendaal, L.; Jonas, F.; Freitag, D.; Pielartzik, H.; Reynolds, J.R. Poly(3, 4-ethylenedioxythiophene) and its derivatives: Past, present, and future. Adv. Mater. 2000, 12, 481–534. [Google Scholar] [CrossRef]
  40. Genies, E.M.; Bidan, G.; Diaz, A.F. Spectroelectrochemical study of polypyrrole films. J. Electroanal. Chem. 1983, 149, 101–113. [Google Scholar] [CrossRef]
  41. Amatore, C.; Savéant, J.-M. ECE and disproportionation: Part, V. Stationary state general solution application to linear sweep voltammetry. J. Electroanal. Chem. 1977, 85, 27–46. [Google Scholar]
  42. Andrieux, C.P.; Audebert, P.; Hapiot, P.; Savéant, J.-M. Identification of the first steps of the electrochemical polymerization of pyrroles by means of fast potential step techniques. J. Phys. Chem. 1991, 95, 10158–10164. [Google Scholar] [CrossRef]
  43. McTiernan, C.D.; Chahma, M. Synthesis and characterization of alanine functionalized oligo/polythiophenes. New J. Chem. 2010, 34, 1417–1423. [Google Scholar] [CrossRef]
  44. McTiernan, C.D.; Omri, K.; Chahma, M. Chiral conducting surfaces via electrochemical oxidation of l-leucine-oligothiophenes. J. Org. Chem. 2010, 75, 6096–6103. [Google Scholar] [CrossRef] [PubMed]
  45. Elgrishi, N.; Rountree, K.J.; McCarthy, B.D.; Rountree, E.S.; Eisenhart, T.T.; Dempsey, J.L. A practical beginner’s guide to cyclic voltammetry. J. Chem. Educ. 2018, 95, 197–206. [Google Scholar] [CrossRef]
  46. Bard, A.J.; Faulkner, L.R. Electrochemical Methods. Fundamentals and Applications, 2nd ed.; Wiley: New York, NY, USA, 2001. [Google Scholar]
  47. Chahma, M.; McTiernan, C.D.; Abbas, S.A. Characterization of phenomena occurring at the interface of chiral conducting surfaces. New J. Chem. 2014, 38, 3379–3385. [Google Scholar] [CrossRef]
  48. Hu, D.; Lu, B.; Duan, X.; Xu, J.; Zhang, L.; Zhang, K.; Zhang, S.; Zhen, S. Synthesis of novel chiral l-leucine grafted PEDOT derivatives with excellent electrochromic performances. RSC Adv. 2014, 4, 35597–35608. [Google Scholar] [CrossRef]
  49. Grenier, R.G.; George, S.J.; Joncheray, T.J.; Meijer, E.W.; Reynolds, J.R. Chiral ethylhexyl substituents for optically active aggregates of π-conjugated polymers. J. Am. Chem. Soc. 2007, 129, 10694–10699. [Google Scholar] [CrossRef] [PubMed]
  50. Hu, D.; Lu, B.; Zhang, K.; Sun, X.; Xu, J.; Duan, X.; Dong, L.; Sun, H.; Zhu, X.; Zhen, S. Synthesis of novel chiral l-phenylalanine grafted PEDOT derivatives with electrochemical chiral sensor for 3,4-dihydroxyphenylalanine discrimination. Int. J. Electrochem. Sci. 2015, 10, 3065–3081. [Google Scholar]
  51. Dong, L.; Lu, B.; Duan, X.; Xu, J.; Hu, D.; Zhang, K.; Zhu, X.; Sun, H.; Ming, S.; Wang, Z.; et al. Novel chiral PEDOTs for selective recognition of 3, 4-dihydroxyphenylalanine enantiomers: Synthesis and characterization. J. Polym. Sci. Part A Polym. Chem. 2015, 53, 2238–2251. [Google Scholar] [CrossRef]
  52. Dong, L.; Zhang, Y.; Duan, X.; Zhu, X.; Su, H.; Xu, J. Chiral PEDOT-based enantioselective electrode modification material for chiral electrochemical sensing: Mechanism and model of chiral recognition. Anal. Chem. 2017, 89, 9695–9702. [Google Scholar] [CrossRef]
  53. Arnaboldi, S.; Benincori, T.; Cirilli, R.; Grecchi, S.; Santagostini, L.; Sannicolò, F.; Mussini, P.R. “Inherently chiral” thiophene-based electrodes at work: A screening of enantioselection ability toward a series of pharmaceutically relevant phenolic or catecholic amino acids, amino esters, and amine. Anal. Bioanal. Chem. 2016, 408, 7243–7254. [Google Scholar] [CrossRef] [PubMed]
  54. Arnaboldi, S.; Benincori, T.; Cirilli, R.; Kutner, W.; Magni, M.; Mussini, P.R.; Noworyta, K.; Sannicolò, F. Inherently chiral electrodes: The tool for chiral voltammetry. Chem. Sci. 2015, 6, 1706–1711. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  55. Wattanakit, C.; Côme, Y.; Lapeyre, V.; Bopp, P.A.; Heim, M.; Yadnum, S.; Nokbin, S.; Warakulwit, C.; Limtrakul, J.; Kuhn, A. Enantioselective recognition at mesoporous chiral metal surfaces. Nat. Commun. 2014, 5, 3325. [Google Scholar] [CrossRef]
  56. Liu, Y.; Cao, X.; Liu, Z.; Sun, L.; Fang, G.; Liu, J.; Wang, S. Electrochemical detection of organophosphorus pesticides based on amino acids-conjugated P3TAA-modified electrodes. Analyst 2020, 145, 8068–8076. [Google Scholar] [CrossRef] [PubMed]
  57. Xu, M.-L.; Gao, Y.; Han, X.X.; Zhao, B. Detection of pesticide residues in food using surface-enhanced Raman spectroscopy: A review. J. Agric. Food Chem. 2017, 65, 6719–6726. [Google Scholar] [CrossRef] [PubMed]
  58. Pernites, R.B.; Venkata, S.K.; Tiu, B.D.B.; Yago, A.C.C.; Advincula, R.C. Nanostructured, molecularly imprinted, and template-patterned polythiophenes for chiral sensing and differentiation. Small 2012, 8, 1669–1674. [Google Scholar] [CrossRef] [PubMed]
  59. Duan, D.; Yang, H.; Ding, Y.; Li, L.; Ma, G. A three-dimensional conductive molecularly imprinted electrochemical sensor based on MOF derived porous carbon/carbon nanotubes composites and prussian blue nanocubes mediated amplification for chiral analysis of cysteine enantiomers. Electrochim. Acta 2019, 302, 137–144. [Google Scholar] [CrossRef]
  60. Shoja, Y.; Rafati, A.A.; Ghodsi, J. Polythiophene supported MnO2 nanoparticles as nano-stabilizer for simultaneously electrostatically immobilization of d-amino acid oxidase and hemoglobin as efficient bio-nanocomposite in fabrication of dopamine bi-enzyme biosensor. Mater. Sci. Eng. C 2017, 76, 637–645. [Google Scholar] [CrossRef] [PubMed]
  61. Liu, R.; Duay, J.; Lee, S.B. Redox exchange induced MnO2 nanoparticle enrichment in poly(3,4-ethylenedioxythiophene) nanowires for electrochemical energy storage. ACS Nano 2010, 4, 4299–4307. [Google Scholar] [CrossRef]
  62. Li, Q.; Xia, Y.; Wan, X.; Yang, S.; Cai, Z.; Ye, Y.; Li, G. Morphology-dependent MnO2/nitrogen-doped graphene nanocomposites for simultaneous detection of trace dopamine and uric acid. Mater. Sci. Eng. C 2020, 109, 110615. [Google Scholar] [CrossRef] [PubMed]
  63. Borazjani, M.; Mehdinia, A.; Jabbari, A. An enantioselective electrochemical sensor for simultaneous determination of mandelic acid enantiomers using dexamethasone-based chiral nanocomposite coupled with chemometrics method. J. Electroanal. Chem. 2017, 805, 83–90. [Google Scholar] [CrossRef]
  64. Niu, X.; Yang, X.; Mo, Z.; Pan, Z.; Liu, Z.; Shuai, C.; Gao, Q.; Liu, N.; Guo, R. Electrochemical chiral recognition at molecular imprinting Au surfaces. J. Electrochem. Soc. 2019, 166, B1126–B1130. [Google Scholar] [CrossRef]
  65. Ning, G.; Wang, H.; Fu, M.; Liu, J.; Sun, Y.; Lu, H.; Fan, X.; Zhang, Y.; Wang, H. Dual signals electrochemical biosensor for point-of-care testing of amino acids enantiomers. Electroanalysis 2021. [Google Scholar] [CrossRef]
  66. Zeng, X.; Li, N.; Wang, J. Electrochemical synthesis of (poly) dimethoxyaniline on glassy carbon electrodes and their applications in the detection of l and d-glutamic acids. J. Electrochem. Soc. 2019, 166, B3066–B3071. [Google Scholar] [CrossRef]
  67. Pandey, I.; Kant, R. Electrochemical impedance based chiral analysis of anti-ascorbutic drug: L-Ascorbic acid and d-ascorbic acid using C-dots decorated conductive polymer nano-composite electrode. Biosens. Bioelectron. 2016, 77, 715–724. [Google Scholar] [CrossRef]
  68. Shi, X.; Wang, Y.; Peng, C.; Zhang, Z.; Chen, J.; Zhou, X.; Jiang, H. Enantiorecognition of tyrosine based on a novel magnetic electrochemical chiral sensor. Electrochim. Acta 2017, 241, 386–394. [Google Scholar] [CrossRef]
  69. Zou, J.; Yu, J.G. Chiral recognition of tyrosine enantiomers on a novel bis-aminosaccharides composite modified glassy carbon electrode. Anal. Chim. Acta 2019, 1088, 35–44. [Google Scholar] [CrossRef] [PubMed]
  70. Lei, P.; Zhou, Y.; Zhang, G.; Zhang, Y.; Zhang, C.; Hong, S.; Yang, Y.; Dong, C.; Shuang, S. A highly efficient chiral sensing platform for tryptophan isomers based on a coordination self-assembly. Talanta 2019, 195, 306–312. [Google Scholar] [CrossRef] [PubMed]
Scheme 1. Synthetic route of chiral electrodes poly1-R and poly1-S.
Scheme 1. Synthetic route of chiral electrodes poly1-R and poly1-S.
Electrochem 02 00042 sch001
Scheme 2. Chiral polythiophenes as electrochemical biosensors.
Scheme 2. Chiral polythiophenes as electrochemical biosensors.
Electrochem 02 00042 sch002
Scheme 3. Electropolymerization mechanism of thiophene monomers. E: Electrochemical reaction; C: Chemical reaction.
Scheme 3. Electropolymerization mechanism of thiophene monomers. E: Electrochemical reaction; C: Chemical reaction.
Electrochem 02 00042 sch003
Scheme 4. Amino acid (AA) functionalized terthiophenes.
Scheme 4. Amino acid (AA) functionalized terthiophenes.
Electrochem 02 00042 sch004
Figure 1. (A) The 10 scan electrochemical oxidation of terth-Ala-OMe (2) in ACN. (B) poly2-Pt at different scan rates. Reprinted with permission from reference [43]. Copyright 2010 The Royal Society of Chemistry.
Figure 1. (A) The 10 scan electrochemical oxidation of terth-Ala-OMe (2) in ACN. (B) poly2-Pt at different scan rates. Reprinted with permission from reference [43]. Copyright 2010 The Royal Society of Chemistry.
Electrochem 02 00042 g001
Scheme 5. Chiral 3,4-ethylenedioxythiophene (EDOT) derivatives.
Scheme 5. Chiral 3,4-ethylenedioxythiophene (EDOT) derivatives.
Electrochem 02 00042 sch005
Figure 2. (A) Capacitive current of poly4-Pt (solid line) at concentrations 0 and 1 M of LeuOMe (dash line), (B) The capacitive current of poly3-Pt before (solid line) and after (dash line) addition of LeuOMe (1 mM), (C) 1H-NMR of 1 in the absence (top) and in the presence (bottom) of one equivalent of LeuOMe. Reprinted with permission from reference [47]. Copyright 2014 The Royal Society of Chemistry.
Figure 2. (A) Capacitive current of poly4-Pt (solid line) at concentrations 0 and 1 M of LeuOMe (dash line), (B) The capacitive current of poly3-Pt before (solid line) and after (dash line) addition of LeuOMe (1 mM), (C) 1H-NMR of 1 in the absence (top) and in the presence (bottom) of one equivalent of LeuOMe. Reprinted with permission from reference [47]. Copyright 2014 The Royal Society of Chemistry.
Electrochem 02 00042 g002
Figure 3. DPVs of with poly7-R-GCE (A) and poly7-S-GCE (B) modified electrodes in 0.25 M H2SO4 containing 0.5 mM d-DOPA (solid line) or l-DOPA (dashed line. Reprinted with permission from reference [51]. Copyright 2015 Wiley.
Figure 3. DPVs of with poly7-R-GCE (A) and poly7-S-GCE (B) modified electrodes in 0.25 M H2SO4 containing 0.5 mM d-DOPA (solid line) or l-DOPA (dashed line. Reprinted with permission from reference [51]. Copyright 2015 Wiley.
Electrochem 02 00042 g003
Scheme 6. Interaction of DOPA (A) and its oxidation (B).
Scheme 6. Interaction of DOPA (A) and its oxidation (B).
Electrochem 02 00042 sch006
Scheme 7. Detection organophosphorus pesticides.
Scheme 7. Detection organophosphorus pesticides.
Electrochem 02 00042 sch007
Figure 4. Electrochemical standard curve of the actual samples of (a) methyl paraoxon, (b) methyl parathion and (c) ethyl paraoxon with varying concentrations. Reprinted with permission from reference [56]. Copyright 2020 The Royal Society of Chemistry.
Figure 4. Electrochemical standard curve of the actual samples of (a) methyl paraoxon, (b) methyl parathion and (c) ethyl paraoxon with varying concentrations. Reprinted with permission from reference [56]. Copyright 2020 The Royal Society of Chemistry.
Electrochem 02 00042 g004
Figure 5. EC-QCM in situ measurements of the CV electrodeposition of the MIP film onto PS- (500 nm size) templated Au surface: (a) CV diagram and (b) QCM response. Reprinted with permission from reference [58]. Copyright 2012 Wiley.
Figure 5. EC-QCM in situ measurements of the CV electrodeposition of the MIP film onto PS- (500 nm size) templated Au surface: (a) CV diagram and (b) QCM response. Reprinted with permission from reference [58]. Copyright 2012 Wiley.
Electrochem 02 00042 g005
Figure 6. QCM sensing of 250 μM concentration of (a) (−)-norephedrine, (b) (+)-norephedrine, (c) (−)-norephedrine sensing calibration plot of the MIP film versus the NIP (control) and (d) comparison of the sensing response of the PS and non-PS-templated MIP film. Reprinted with permission from reference [58]. Copyright 2012 Wiley.
Figure 6. QCM sensing of 250 μM concentration of (a) (−)-norephedrine, (b) (+)-norephedrine, (c) (−)-norephedrine sensing calibration plot of the MIP film versus the NIP (control) and (d) comparison of the sensing response of the PS and non-PS-templated MIP film. Reprinted with permission from reference [58]. Copyright 2012 Wiley.
Electrochem 02 00042 g006
Figure 7. Left: Fabrication steps of the DAAO-Hb/MnO2 NPs/PTh/GCE bi-enzyme biosensor. Right: CVs of (a) bare GCE, (b) PTh/GCE, (c) MnO2 NPs/PTh/GCE and (d) DAAO-Hb/MnO2 NPs/PTh/GCE in PBS solution (100 mM, pH = 6) containing 200 μM d-alanine and 5 μM DAAO at scan rate of 100 mV/s. Reprinted with permission from reference [60]. Copyright 2017 Elsevier.
Figure 7. Left: Fabrication steps of the DAAO-Hb/MnO2 NPs/PTh/GCE bi-enzyme biosensor. Right: CVs of (a) bare GCE, (b) PTh/GCE, (c) MnO2 NPs/PTh/GCE and (d) DAAO-Hb/MnO2 NPs/PTh/GCE in PBS solution (100 mM, pH = 6) containing 200 μM d-alanine and 5 μM DAAO at scan rate of 100 mV/s. Reprinted with permission from reference [60]. Copyright 2017 Elsevier.
Electrochem 02 00042 g007
Table 1. Examples of electrochemical chiral electrode sensors.
Table 1. Examples of electrochemical chiral electrode sensors.
Electrode Construction DetectionLODRef
Leu/PTh/PtLeuOMe/AlaOMe1 mM[47]
PTh/GCE1,4-Dihydroxyphenylalanine 0.50 mM[51]
Norephedrine/PTh/QCMNorephedrine0.25 mM[58]
His-Ser-Glu/PTh/GCEOrganophosphorus0.50 µM[56]
DAAO-Hb/MnO2 NPs/PTh/GCEDopamine40 nM[60]
DAAO-Hb/MnO2 NPs/GCEDopamine0.039 µM[62]
PPy-DEX/GR/GCE Mandelic acid0.25 mM[63]
Trp/PPy/Aul-Tryptophan, d-Tryptophan0.012 μM, 0.009 μM [64]
L/D-CNT/PPy/PtAmino acids (Tryptophan)0.107 nM [65]
PANi/GCEl-Glutamic acid0.011 mM[66]
PANI-FSA/PGE l-Ascorbic acid7.3–4.5 10−4 nM[67]
L-Cys-Au/Fe3O4-NP l-and d-Tyrosine0.021–0.084 μM [68]
GCEl-Tyrosine, d-Tyrosine0.65, 0.86 mM[69]
Cu-β-CD/PLA/MWCN/GCE.Tryptophan3.3 10−7 M[70]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Chahma, M. Doped Polythiophene Chiral Electrodes as Electrochemical Biosensors. Electrochem 2021, 2, 677-688. https://doi.org/10.3390/electrochem2040042

AMA Style

Chahma M. Doped Polythiophene Chiral Electrodes as Electrochemical Biosensors. Electrochem. 2021; 2(4):677-688. https://doi.org/10.3390/electrochem2040042

Chicago/Turabian Style

Chahma, M’hamed. 2021. "Doped Polythiophene Chiral Electrodes as Electrochemical Biosensors" Electrochem 2, no. 4: 677-688. https://doi.org/10.3390/electrochem2040042

APA Style

Chahma, M. (2021). Doped Polythiophene Chiral Electrodes as Electrochemical Biosensors. Electrochem, 2(4), 677-688. https://doi.org/10.3390/electrochem2040042

Article Metrics