Micromixers

A special issue of Micromachines (ISSN 2072-666X).

Deadline for manuscript submissions: closed (28 February 2010) | Viewed by 50447

Special Issue Editor


E-Mail Website
Guest Editor
Queensland Micro- and Nanotechnology Centre, Griffith University, West Creek Road, Nathan, QLD 4111, Australia
Interests: microfluidics; nanofluidics; micro/nanomachining technologies; micro/nanoscale science; instrumentation for biomedical applications
Special Issues, Collections and Topics in MDPI journals

Special Issue Information

Dear Colleagues,

Micromixer is a key component in a number of microsystems, especially lab-on-a-chip. Micromixers are miniaturized mixing devices for at least two different phases that can be liquids, solids or gases. The structures of a micromixer are fabricated partially or in whole using microtechnology or precision engineering. The characteristic channel size of micromixers is in the sub-millimeter range. Common channel widths are on the order of 100 to 500 μm, while channel length could be a few millimeters or more. The channel height is on the order of the channel width or smaller. The overall volume defined by a micromixer is from microliters to milliliters. Compared with molecular size scale, the length scale and volume scale of micromixers are still very large. This fact leads to two key characteristics of micromixers. First, designing micromixers still relies on manipulating the flow using channel geometry or external disturbances. Secondly, while micromixers bring advantages and new features into chemical engineering, molecular level processes such as reaction kinetics remain almost unchanged. The laminar flow regime poses a challenge to designers of micromixers. New mixing concepts and the optimization of known concepts are the hot research topics in recent years. This special issue aims at attracting and publishing the latest works on micromixers.

Nam-Trung Nguyen, Ph.D.
Guest Editor

Keywords

  • micromixers
  • microfluidics
  • nanofluidics
  • molecular diffusion
  • chaotic advection

Benefits of Publishing in a Special Issue

  • Ease of navigation: Grouping papers by topic helps scholars navigate broad scope journals more efficiently.
  • Greater discoverability: Special Issues support the reach and impact of scientific research. Articles in Special Issues are more discoverable and cited more frequently.
  • Expansion of research network: Special Issues facilitate connections among authors, fostering scientific collaborations.
  • External promotion: Articles in Special Issues are often promoted through the journal's social media, increasing their visibility.
  • e-Book format: Special Issues with more than 10 articles can be published as dedicated e-books, ensuring wide and rapid dissemination.

Further information on MDPI's Special Issue polices can be found here.

Published Papers (3 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Review

728 KiB  
Article
Analysis of Electrokinetic Mixing Techniques Using Comparative Mixing Index
by Mranal Jain, Anthony Yeung and Krishnaswamy Nandakumar
Micromachines 2010, 1(2), 36-47; https://doi.org/10.3390/mi1020036 - 12 Jul 2010
Cited by 8 | Viewed by 6494
Abstract
The performance of micro-mixers is evaluated in terms of deviations from perfectly mixed state and mixing length (i.e., device length required to achieve perfect mixing). Different variations of T-mixer are reported for improved mixing performance, including geometric constrictions/obstacles embedded in the [...] Read more.
The performance of micro-mixers is evaluated in terms of deviations from perfectly mixed state and mixing length (i.e., device length required to achieve perfect mixing). Different variations of T-mixer are reported for improved mixing performance, including geometric constrictions/obstacles embedded in the channel wall, heterogeneously charged walls, grooves on channel base, etc. Most of the reported designs provide improved mixing at the expense of reduced flow rate; there exists therefore a tradeoff between mixing and transport. The reduced flow rate, which affects species residence time, is unfortunately not taken into account in most micro-mixing performance analyses. This issue is addressed by the comparative mixing index (CMI), which evaluates mixing performance more appropriately by normalizing the effect of residence time among different designs. In this study, the performance of several mixing strategies are evaluated based on the CMI; these are mixer designs that incorporate (a) physical constrictions, (b) induced charge electro-osmotic (ICEO) effects, and (c) heterogeneously charged walls. The present analysis clearly identifies conditions under which a given mixer design is superior to a T-mixer. Full article
(This article belongs to the Special Issue Micromixers)
Show Figures

Figure 1

2437 KiB  
Article
Evaluation of Floor-grooved Micromixers using Concentration-channel Length Profiles
by Yan Du, Zhiyi Zhang, ChaeHo Yim, Min Lin and Xudong Cao
Micromachines 2010, 1(1), 19-33; https://doi.org/10.3390/mi1010019 - 17 May 2010
Cited by 38 | Viewed by 7730
Abstract
We evaluated the dynamic micromixing performances in slanted groove micromixers (SGM) and staggered herringbone micromixers (SHM) and quantitatively compared their differences using concentration vs. channel length profiles obtained from numerical stimulations. It is found that faster and finer mixing took place in the [...] Read more.
We evaluated the dynamic micromixing performances in slanted groove micromixers (SGM) and staggered herringbone micromixers (SHM) and quantitatively compared their differences using concentration vs. channel length profiles obtained from numerical stimulations. It is found that faster and finer mixing took place in the SHM and the chaotic mixing was more effective at locations closer to the grooves; in comparison, slower and coarser mixing occurred throughout the whole channel of the SGM. Subsequently, the concentration profile-based characterization method was demonstrated in hybrid floor-grooved micromixers to study the interaction of SGM and SHM. Full article
(This article belongs to the Special Issue Micromixers)
Show Figures

Figure 1

Review

Jump to: Research

6745 KiB  
Review
Microvalves and Micropumps for BioMEMS
by Anthony K. Au, Hoyin Lai, Ben R. Utela and Albert Folch
Micromachines 2011, 2(2), 179-220; https://doi.org/10.3390/mi2020179 - 24 May 2011
Cited by 291 | Viewed by 35282
Abstract
This review presents an extensive overview of a large number of microvalve and micropump designs with great variability in performance and operation. The performance of a given design varies greatly depending on the particular assembly procedure and there is no standardized performance test [...] Read more.
This review presents an extensive overview of a large number of microvalve and micropump designs with great variability in performance and operation. The performance of a given design varies greatly depending on the particular assembly procedure and there is no standardized performance test against which all microvalves and micropumps can be compared. We present the designs with a historical perspective and provide insight into their advantages and limitations for biomedical uses. Full article
(This article belongs to the Special Issue Micromixers)
Show Figures

Back to TopTop