Kolmogorov Complexity of Coronary Sinus Atrial Electrograms Before Ablation Predicts Termination of Atrial Fibrillation After Pulmonary Vein Isolation
Abstract
:1. Introduction
2. Materials and Methods
2.1. Study Population and Catheter Ablation Procedure
2.2. Complexity of Electrograms
2.2.1. Linear Methods
2.2.2. Non-Linear Methods
2.3. Statistical Analysis
3. Results
4. Discussion
4.1. Kolmogorov Complexity in AF Electrogram Complexity Assessment
4.2. Literature Overview
4.3. Physiological Meaning of the Results
4.4. Clinical Implications
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Conflicts of Interest
Abbreviations
ACI | Average Complex Interval |
AF | Atrial Fibrillation |
AFCL | Atrial Fibrillation Cycle Length |
BDM | Block Decomposition Method |
CEA | Continuous Electrical Activity |
CFAE | Complex Fractionated Atrial Electrograms |
CS | Coronary Sinus |
DF | Dominant Frequency |
ICL | Interval Confidence Level |
LPV | Left Pulmonary Vein |
LZC | Lempel–Ziv Complexity |
OI | Organization Index |
PV | Pulmonary Veins |
PVI | Pulmonary Veins Isolation |
RI | Regularization Index; |
RPV | Right Pulmonary Vein |
SampEn | Sample Entropy |
ShEn | Shannon Entropy |
SCI | Shortest Complex Interval |
WMSI | Wave Morphology Similarity Index |
Appendix A
Appendix B
Appendix C
FIRST WINDOW | 2 s | 10 s | 30 s | |||
---|---|---|---|---|---|---|
Method | p-Value | Area Under ROC Curve | p-Value | Area Under ROC Curve | p-Value | Area Under ROC Curve |
LZC | 0.026 | 0.74 | 0.009 | 0.78 | 0.006 | 0.79 |
BDM | 0.023 | 0.76 | 0.007 | 0.79 | 0.006 | 0.83 |
ShanEn | 0.123 | 0.73 | 0.066 | 0.73 | 0.068 | 0.74 |
AFCL | 0.702 | 0.44 | 0.700 | 0.54 | 0.986 | 0.52 |
DF | 0.521 | 0.48 | 0.865 | 0.52 | 0.775 | 0.52 |
DF RI | 0.405 | 0.58 | 0.368 | 0.59 | 0.032 | 0.74 |
DF OI | 0.930 | 0.48 | 0.506 | 0.60 | 0.096 | 0.69 |
NavX CFAE | 0.232 | 0.38 | 0.203 | 0.64 | 0.203 | 0.66 |
CEA | 0.580 | 0.53 | 0.611 | 0.51 | 0.597 | 0.51 |
ICL | 0.200 | 0.36 | 0.443 | 0.47 | 0.562 | 0.48 |
ACI | 0.834 | 0.55 | 0.973 | 0.49 | 0.737 | 0.47 |
SCI | 0.625 | 0.56 | 0.320 | 0.59 | 0.779 | 0.48 |
SampEn | 0.887 | 0.58 | 0.826 | 0.52 | 0.743 | 0.53 |
WMS | 0.163 | 0.33 | 0.054 | 0.26 | 0.698 | 0.26 |
MEAN WINDOW | 2 s | 5 s | 10 s | |||
---|---|---|---|---|---|---|
Method | p-Value | Area Under ROC Curve | p-Value | Area Under ROC Curve | p-Value | Area Under ROC Curve |
LZC | 0.005 | 0.82 | 0.005 | 0.82 | 0.005 | 0.84 |
BDM | 0.007 | 0.80 | 0.004 | 0.83 | 0.003 | 0.85 |
ShanEn | 0.064 | 0.77 | 0.052 | 0.77 | 0.040 | 0.79 |
AFCL | 0.964 | 0.53 | 0.990 | 0.52 | 0.822 | 0.52 |
DF | 0.821 | 0.52 | 0.841 | 0.51 | 0.815 | 0.48 |
DF RI | 0.435 | 0.57 | 0.099 | 0.69 | 0.099 | 0.69 |
DF OI | 0.866 | 0.55 | 0.880 | 0.57 | 0.214 | 0.65 |
NavX CFAE | 0.579 | 0.58 | 0.252 | 0.69 | 0.180 | 0.67 |
CEA | 0.579 | 0.53 | 0.584 | 0.51 | 0.573 | 0.53 |
ICL | 0.641 | 0.47 | 0.618 | 0.48 | 0.601 | 0.48 |
ACI | 0.233 | 0.33 | 0.933 | 0.49 | 0.724 | 0.44 |
SCI | 0.306 | 0.55 | 0.442 | 0.58 | 0.940 | 0.52 |
SampEn | 0.729 | 0.53 | 0.728 | 0.53 | 0.729 | 0.53 |
WMS | 0.068 | 0.25 | 0.071 | 0.26 | 0.063 | 0.26 |
Appendix D
Method | LZC | BDM | ShanEn | AFCL | DF | DF RI | DF OI | NavX | CEA | ICL | ACI | SCI | SampEn | WMS |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LZC | -- | 0.98 | 0.72 | −0.25 | −0.06 | 0.65 | 0.16 | −0.33 | 0.31 | 0.04 | −0.56 | −0.36 | 0.08 | −0.64 |
BDM | 0.98 | -- | 0.71 | −0.26 | −0.03 | 0.67 | 0.16 | −0.38 | 0.28 | 0.01 | −0.52 | −0.31 | 0.08 | −0.61 |
ShanEn | 0.72 | 0.71 | -- | −0.17 | −0.01 | 0.41 | −0.03 | −0.02 | 0.57 | 0.28 | −0.59 | −0.58 | 0.25 | −0.63 |
AFCL | −0.25 | −0.26 | −0.17 | -- | −0.42 | −0.26 | 0.66 | 0.33 | −0.15 | −0.42 | 0.13 | 0.14 | −0.24 | −0.03 |
DF | −0.06 | −0.03 | −0.01 | −0.42 | -- | 0.24 | −0.77 | −0.20 | 0.07 | 0.43 | −0.04 | −0.13 | 0.07 | 0.15 |
DF RI | 0.65 | 0.67 | 0.41 | −0.26 | 0.24 | -- | −0.10 | 0.01 | −0.08 | 0.03 | −0.17 | 0.00 | −0.31 | −0.40 |
DF OI | 0.16 | 0.16 | −0.03 | 0.66 | −0.77 | −0.10 | -- | 0.05 | −0.07 | −0.43 | −0.10 | 0.07 | −0.07 | −0.19 |
NavX | −0.33 | −0.38 | −0.02 | 0.33 | −0.20 | 0.01 | 0.05 | -- | −0.21 | −0.04 | 0.38 | 0.19 | −0.40 | 0.04 |
CEA | 0.31 | 0.28 | 0.57 | −0.15 | 0.07 | −0.08 | −0.07 | −0.21 | -- | 0.30 | −0.61 | −0.62 | 0.84 | −0.36 |
ICL | 0.04 | 0.01 | 0.28 | −0.42 | 0.43 | 0.03 | −0.43 | −0.04 | 0.30 | -- | −0.35 | −0.57 | 0.19 | −0.14 |
ACI | −0.56 | −0.52 | −0.59 | 0.13 | −0.04 | −0.17 | −0.10 | 0.38 | −0.61 | −0.35 | -- | 0.87 | −0.47 | 0.44 |
SCI | −0.36 | −0.31 | −0.58 | 0.14 | −0.13 | 0.00 | 0.07 | 0.19 | −0.62 | −0.57 | 0.87 | -- | −0.45 | 0.43 |
SampEn | 0.08 | 0.08 | 0.25 | −0.24 | 0.07 | −0.31 | −0.07 | −0.40 | 0.84 | 0.19 | −0.47 | −0.45 | -- | −0.18 |
WMS | −0.64 | −0.61 | −0.63 | −0.03 | 0.15 | −0.40 | −0.19 | 0.04 | −0.36 | −0.14 | 0.44 | 0.43 | −0.18 | -- |
Method | LZC | BDM | ShanEn | AFCL | DF | DF RI | DF OI | NavX | CEA | ICL | ACI | SCI | SampEn | WMS |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LZC | -- | 0.99 | 0.78 | −0.05 | −0.08 | 0.03 | −0.08 | −0.10 | 0.37 | 0.07 | −0.20 | 0.07 | 0.03 | −0.62 |
BDM | 0.99 | -- | 0.82 | −0.04 | −0.09 | 0.03 | −0.09 | −0.07 | 0.40 | 0.09 | −0.24 | 0.07 | 0.05 | −0.59 |
ShanEn | 0.78 | 0.82 | -- | −0.11 | −0.06 | 0.01 | −0.11 | 0.16 | 0.61 | 0.35 | −0.38 | −0.17 | 0.22 | −0.61 |
AFCL | −0.05 | −0.04 | −0.11 | -- | −0.83 | 0.12 | 0.19 | −0.22 | 0.02 | −0.40 | −0.17 | −0.03 | −0.06 | 0.07 |
DF | −0.08 | −0.09 | −0.06 | −0.83 | -- | 0.12 | −0.29 | 0.12 | −0.21 | 0.26 | 0.26 | 0.28 | −0.04 | 0.11 |
DF RI | 0.03 | 0.03 | 0.01 | 0.12 | 0.12 | -- | 0.27 | 0.16 | −0.37 | −0.35 | 0.35 | 0.58 | −0.58 | 0.22 |
DF OI | −0.08 | −0.09 | −0.11 | 0.19 | −0.29 | 0.27 | -- | −0.01 | −0.04 | −0.21 | 0.15 | 0.08 | −0.11 | 0.29 |
NavX | −0.10 | −0.07 | 0.16 | −0.22 | 0.12 | 0.16 | −0.01 | -- | −0.21 | 0.01 | 0.26 | 0.20 | −0.45 | 0.17 |
CEA | 0.37 | 0.40 | 0.61 | 0.02 | −0.21 | −0.37 | −0.04 | −0.21 | -- | 0.65 | −0.72 | −0.68 | 0.78 | −0.41 |
ICL | 0.07 | 0.09 | 0.35 | −0.40 | 0.26 | −0.35 | −0.21 | 0.01 | 0.65 | -- | −0.47 | −0.69 | 0.49 | −0.29 |
ACI | −0.20 | −0.24 | −0.38 | −0.17 | 0.26 | 0.35 | 0.15 | 0.26 | −0.72 | −0.47 | -- | 0.59 | −0.66 | 0.26 |
SCI | 0.07 | 0.07 | −0.17 | −0.03 | 0.28 | 0.58 | 0.08 | 0.20 | −0.68 | −0.69 | 0.59 | -- | −0.66 | 0.40 |
SampEn | 0.03 | 0.05 | 0.22 | −0.06 | −0.04 | −0.58 | −0.11 | −0.45 | 0.78 | 0.49 | −0.66 | −0.66 | -- | −0.23 |
WMS | −0.62 | −0.59 | −0.61 | 0.07 | 0.11 | 0.22 | 0.29 | 0.17 | −0.41 | −0.29 | 0.26 | 0.40 | −0.23 | -- |
Method | LZC | BDM | ShanEn | AFCL | DF | DF RI | DF OI | NavX | CEA | ICL | ACI | SCI | SampEn | WMS |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LZC | -- | 0.99 | 0.77 | −0.04 | −0.15 | 0.11 | 0.37 | 0.54 | 0.35 | 0.05 | −0.15 | −0.15 | 0.06 | −0.59 |
BDM | 0.99 | -- | 0.79 | −0.02 | −0.17 | 0.06 | 0.38 | 0.48 | 0.37 | 0.05 | −0.16 | −0.14 | 0.09 | −0.59 |
ShanEn | 0.77 | 0.79 | -- | −0.11 | −0.09 | 0.20 | 0.12 | 0.17 | 0.61 | 0.35 | −0.40 | −0.50 | 0.24 | −0.55 |
AFCL | −0.04 | −0.02 | −0.11 | -- | −0.64 | 0.00 | 0.25 | 0.14 | −0.06 | −0.56 | −0.11 | 0.27 | −0.21 | −0.09 |
DF | −0.15 | −0.17 | −0.09 | −0.64 | -- | 0.20 | −0.52 | −0.10 | −0.08 | 0.31 | 0.10 | −0.07 | 0.05 | 0.20 |
DF RI | 0.11 | 0.06 | 0.20 | 0.00 | 0.20 | -- | −0.11 | 0.17 | −0.14 | −0.12 | 0.07 | 0.27 | −0.36 | −0.03 |
DF OI | 0.37 | 0.38 | 0.12 | 0.25 | −0.52 | −0.11 | -- | 0.07 | −0.03 | −0.26 | 0.15 | 0.10 | 0.08 | −0.50 |
NavX | 0.54 | 0.48 | 0.17 | 0.14 | −0.10 | 0.17 | 0.07 | -- | −0.33 | −0.48 | 0.22 | 0.24 | −0.48 | −0.16 |
CEA | 0.35 | 0.37 | 0.61 | −0.06 | −0.08 | −0.14 | −0.03 | −0.33 | -- | 0.58 | −0.80 | −0.60 | 0.79 | −0.26 |
ICL | 0.05 | 0.05 | 0.35 | −0.56 | 0.31 | −0.12 | −0.26 | −0.48 | 0.58 | -- | −0.36 | −0.71 | 0.46 | −0.07 |
ACI | −0.15 | −0.16 | −0.40 | −0.11 | 0.10 | 0.07 | 0.15 | 0.22 | −0.80 | −0.36 | -- | 0.57 | −0.68 | 0.12 |
SCI | −0.15 | −0.14 | −0.50 | 0.27 | −0.07 | 0.27 | 0.10 | 0.24 | −0.60 | −0.71 | 0.57 | -- | −0.48 | 0.32 |
SampEn | 0.06 | 0.09 | 0.24 | −0.21 | 0.05 | −0.36 | 0.08 | −0.48 | 0.79 | 0.46 | −0.68 | −0.48 | -- | −0.13 |
WMS | −0.59 | −0.59 | −0.55 | −0.09 | 0.20 | −0.03 | −0.50 | −0.16 | −0.26 | −0.07 | 0.12 | 0.32 | -0.13 | -- |
Method | LZC | BDM | ShanEn | AFCL | DF | DF RI | DF OI | NavX | CEA | ICL | ACI | SCI | SampEn | WMS |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LZC | -- | 0.99 | 0.80 | −0.12 | −0.04 | 0.46 | 0.27 | 0.53 | 0.35 | 0.11 | −0.33 | −-0.31 | 0.07 | −0.57 |
BDM | 0.99 | -- | 0.79 | −0.09 | −0.06 | 0.46 | 0.27 | 0.53 | 0.33 | 0.07 | −0.31 | −0.28 | 0.05 | −0.58 |
ShanEn | 0.80 | 0.79 | -- | −0.15 | −0.06 | 0.39 | 0.31 | 0.17 | 0.59 | 0.43 | −0.40 | −0.52 | 0.20 | −0.61 |
AFCL | −0.12 | −0.09 | −0.15 | -- | −0.87 | 0.33 | 0.06 | 0.13 | −0.10 | −0.45 | −0.20 | 0.19 | −0.24 | −0.09 |
DF | −0.04 | −0.06 | −0.06 | −0.87 | -- | −0.35 | −0.20 | −0.08 | 0.02 | 0.34 | 0.18 | −0.14 | 0.23 | 0.26 |
DF RI | 0.46 | 0.46 | 0.39 | 0.33 | −0.35 | -- | 0.20 | 0.41 | −0.02 | −0.26 | −0.30 | −0.36 | −0.29 | −0.45 |
DF OI | 0.27 | 0.27 | 0.31 | 0.06 | −0.20 | 0.20 | -- | −0.12 | 0.47 | 0.04 | −0.28 | 0.21 | 0.25 | −0.35 |
NavX | 0.53 | 0.53 | 0.17 | 0.13 | −0.08 | 0.41 | −0.12 | -- | −0.31 | −0.43 | −0.14 | −0.11 | −0.42 | −0.14 |
CEA | 0.35 | 0.33 | 0.59 | −0.10 | 0.02 | −0.02 | 0.47 | −0.31 | -- | 0.60 | −0.73 | −0.33 | 0.77 | −0.33 |
ICL | 0.11 | 0.07 | 0.43 | −0.45 | 0.34 | −0.26 | 0.04 | −0.43 | 0.60 | -- | −0.21 | −0.31 | 0.46 | −0.18 |
ACI | −0.33 | −0.31 | −0.40 | −0.20 | 0.18 | −0.30 | −0.28 | −0.14 | −0.73 | −0.21 | -- | 0.42 | −0.50 | 0.23 |
SCI | −0.31 | −0.28 | −0.52 | 0.19 | −0.14 | −0.36 | 0.21 | −0.11 | −0.33 | −0.31 | 0.42 | -- | −0.14 | 0.24 |
SampEn | 0.07 | 0.05 | 0.20 | −0.24 | 0.23 | −0.29 | 0.25 | −0.42 | 0.77 | 0.46 | −0.50 | −0.14 | -- | −0.15 |
WMS | −0.57 | −0.58 | −0.61 | −0.09 | 0.26 | −0.45 | −0.35 | −0.14 | −0.33 | −0.18 | 0.23 | 0.24 | −0.15 | -- |
References
- John Camm, A.; Lip, G.Y.H.; De Caterina, R.; Savelieva, I.; Atar, D.; Hohnloser, S.H.; Hindricks, G.; Kirchhof, P.; Bax, J.J.; Baumgartner, H.; et al. 2012 focused update of the ESC Guidelines for the management of atrial fibrillation. Eur. Heart J. 2012, 33, 2719–2747. [Google Scholar] [Green Version]
- Narayan, S.M.; Krummen, D.E.; Shivkumar, K.; Clopton, P.; Rappel, W.J.; Miller, J.M. Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation with or Without Focal Impulse and Rotor Modulation) trial. J. Am. Coll. Cardiol. 2012, 60, 628–636. [Google Scholar] [CrossRef] [PubMed]
- Allessie, M.A.; De Groot, N.M.S.; Houben, R.P.M.; Schotten, U.; Boersma, E.; Smeets, J.L.; Crijns, H.J. Electropathological substrate of long-standing persistent atrial fibrillation in patients with structural heart disease longitudinal dissociation. Circ.-Arrhythmia Electrophysiol 2010, 3, 606–615. [Google Scholar] [CrossRef] [PubMed]
- Weerasooriya, R.; Shah, A.J.; Hocini, M.; Jaïs, P.; Haïsssaguerre, M. Contemporary challenges of catheter ablation for atrial fibrillation. Clin. Ther. 2014, 36, 1145–1150. [Google Scholar] [CrossRef] [PubMed]
- Brooks, A.G.; Stiles, M.K.; Laborderie, J.; Lau, D.H.; Kuklik, P.; Shipp, N.J.; Hsu, L.F.; Sanders, P. Outcomes of long-standing persistent atrial fibrillation ablation: A systematic review. Heart Rhythm 2010, 7, 835–846. [Google Scholar] [CrossRef] [Green Version]
- Haïssaguerre, M.; Jaïs, P.; Shah, D.C.; Takahashi, A.; Hocini, M.; Quiniou, G.; Garrigue, S.; Le Mouroux, A.; Le Métayer, P.; Clémenty, J. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N. Engl. J. Med. 1998, 339, 659–666. [Google Scholar]
- Vogler, J.; Willems, S.; Sultan, A.; Schreiber, D.; Lüker, J.; Servatius, H.; Schäffer, B.; Moser, J.; Hoffmann, B.A.; Steven, D. Pulmonary Vein Isolation Versus Defragmentation the CHASE-AF Clinical Trial. J. Am. Coll. Cardiol. 2015, 66, 2743–2752. [Google Scholar] [CrossRef]
- Verma, A.; Jiang, C.Y.; Betts, T.R.; Chen, J.; Deisenhofer, I.; Mantovan, R.; Macle, L.; Morillo, C.A.; Haverkamp, W.; Weerasooriya, R.; et al. Approaches to catheter ablation for persistent atrial fibrillation. N Engl J Med 2015, 372, 1812–1822. [Google Scholar] [CrossRef]
- Lankveld, T.; Zeemering, S.; Scherr, D.; Kuklik, P.; Hoffmann, B.A.; Willems, S.; Pieske, B.; Haïssaguerre, M.; Jaïs, P.; Crijns, H.J.; et al. Atrial Fibrillation Complexity Parameters Derived from Surface ECGs Predict Procedural Outcome and Long-Term Follow-Up of Stepwise Catheter Ablation for Atrial Fibrillation. Circ.-Arrhythmia Electrophysiol. 2016, 9, e003354. [Google Scholar] [CrossRef]
- Nademanee, K.; Schwab, M.; Porath, J.; Abbo, A. How to perform electrogram-guided atrial fibrillation ablation. Heart Rhythm 2006, 3, 981–984. [Google Scholar] [CrossRef]
- Narayan, S.M.; Shivkumar, K.; Krummen, D.E.; Miller, J.M.; Rappel, W.J. Panoramic electrophysiological mapping but not electrogram morphology identifies stable sources for human atrial fibrillation: Stable atrial fibrillation rotors and focal sources relate poorly to fractionated electrograms. Circ.-Arrhythmia Electrophysiol. 2013, 6, 58–67. [Google Scholar] [CrossRef] [PubMed]
- Buch, E.; Share, M.; Tung, R.; Benharash, P.; Sharma, P.; Koneru, J.; Mandapati, R.; Ellenbogen, K.A.; Shivkumar, K. Long-term clinical outcomes of focal impulse and rotor modulation for treatment of atrial fibrillation: A multicenter experience. Heart Rhythm 2016, 13, 636–641. [Google Scholar] [CrossRef] [PubMed]
- Berntsen, R.F.; Håland, T.F.; Skårdal, R.; Holm, T. Focal impulse and rotor modulation as a stand-alone procedure for the treatment of paroxysmal atrial fibrillation: A within-patient controlled study with implanted cardiac monitoring. Heart Rhythm 2016, 13, 1768–1774. [Google Scholar] [CrossRef] [PubMed]
- Singh, J.P.; Ptaszek, L.M.; Verma, A. Elusive atrial substrate: Complex fractionated atrial electrograms and beyond. Heart Rhythm 2010, 7, 1886–1890. [Google Scholar] [CrossRef]
- Jalife, J.; Berenfeld, O.; Mansour, M. Mother rotors and fibrillatory conduction: A mechanism of atrial fibrillation. Cardiovasc. Res. 2002, 54, 204–216. [Google Scholar] [CrossRef]
- Bonizzi, P.; Zeemering, S.; Karel, J.M.H.; Di Marco, L.Y.; Uldry, L.; Van Zaen, J.; Vesin, J.M.; Schotten, U. Systematic comparison of non-invasive measures for the assessment of atrial fibrillation complexity: A step forward towards standardization of atrial fibrillation electrogram analysis. Europace 2014, 17, 318–325. [Google Scholar] [CrossRef]
- Sanders, P.; Berenfeld, O.; Hocini, M.; Jaïs, P.; Vaidyanathan, R.; Hsu, L.F.; Garrigue, S.; Takahashi, Y.; Rotter, M.; Sacher, F.; et al. Spectral analysis identifies sites of high-frequency activity maintaining atrial fibrillation in humans. Circulation 2005, 112, 789–797. [Google Scholar] [CrossRef]
- Simon, F.; Arenal, A.; Laguna, P.; Martinez, J.P. Stability and correlation of electrogram organization and synchronization indices during Atrial Fibrillation. Comput. Cardiol. 2009, 36, 149–152. [Google Scholar]
- Sezgin, N. Nonlinear Analysis of Electrocardiography Signals for Atrial Fibrillation. Sci. World J. 2013, 2013, 1–4. [Google Scholar] [CrossRef] [Green Version]
- Grunwald, P.; Vitanyi, P. Shannon Information and Kolmogorov Complexity. arXiv 2004, arXiv:cs/0410002. Available online: https://arxiv.org/abs/cs/0410002 (accessed on 1 October 2019).
- Pitschner, H.F.; Berkowitsch, A. Algorithmic complexity. A new approach of non-linear algorithms for the analysis of atrial signals from multipolar basket catheter. Ann. Ist. Super. Sanita 2001, 37, 409–418. [Google Scholar] [PubMed]
- Kaspar, F.; Schuster, H.G. Easily calculable measure for the complexity of spatiotemporal patterns. Phys. Rev. A 1987, 36, 842–848. [Google Scholar] [CrossRef] [PubMed]
- Zenil, H.; Hernández-Orozco, S.; Kiani, N.; Soler-Toscano, F.; Rueda-Toicen, A.; Tegnér, J. A Decomposition Method for Global Evaluation of Shannon Entropy and Local Estimations of Algorithmic Complexity. Entropy 2018, 20, 605. [Google Scholar] [CrossRef]
- Lind, D.; Marcus, B. An introduction to symbolic dynamics and coding. Comput. Math. Appl. 1995, 495. [Google Scholar]
- Iapascurta, V. Detection of Movement toward Randomness by Applying the Block Decomposition Method to a Simple Model of the Circulatory System. Complex Syst. 2019, 28, 59–76. [Google Scholar] [CrossRef]
- Soler-Toscano, F.; Zenil, H.; Delahaye, J.-P.; Gauvrit, N. Calculating Kolmogorov Complexity from the Output Frequency Distributions of Small Turing Machines. PLoS ONE 2014, 9, e96223. [Google Scholar] [CrossRef]
- Ng, J.; Borodyanskiy, A.I.; Chang, E.T.; Villuendas, R.; Dibs, S.; Kadish, A.H.; Goldberger, J.J. Measuring the complexity of atrial fibrillation electrograms. J. Cardiovasc. Electrophysiol. 2010, 21, 649–655. [Google Scholar] [CrossRef]
- Ganesan, A.N.; Kuklik, P.; Gharaviri, A.; Brooks, A.; Chapman, D.; Lau, D.H.; Roberts-Thomson, K.C.; Sanders, P. Origin and characteristics of high shannon entropy at the pivot of locally stable rotors: insights from computational simulation. PLoS ONE 2014, 9, e110662. [Google Scholar] [CrossRef]
- Alcaraz, R.; Abásolo, D.; Hornero, R.; Rieta, J.J. Optimal parameters study for sample entropy-based atrial fibrillation organization analysis. Comput. Meth. Programs Biomed. 2010, 99, 124–132. [Google Scholar] [CrossRef] [Green Version]
- Irusta, U.; Ruiz, J.; De Ruiz Gauna, S.; Aramendi, E. Sequential VT/VF discrimination algorithm based on wave mode sample entropy for adult and pediatric patients. Computers in Cardiology 2007, 34, 229–232. [Google Scholar]
- Faes, L.; Nollo, G.; Antolini, R.; Gaita, F.; Ravelli, F. A method for quantifying atrial fibrillation organization based on wave-morphology similarity. IEEE Trans. Biomed. Eng. 2002, 49, 1504–1513. [Google Scholar] [CrossRef] [PubMed]
- Lau, D.H.; Maesen, B.; Zeemering, S.; Kuklik, P.; Van Hunnik, A.; Lankveld, T.A.R.; Bidar, E.; Verheule, S.; Nijs, J.; Maessen, J.; et al. Indices of bipolar complex fractionated atrial electrograms correlate poorly with each other and atrial fibrillation substrate complexity. Heart Rhythm 2015, 12, 1415–1423. [Google Scholar] [CrossRef] [PubMed]
- Komatsu, Y.; Taniguchi, H.; Miyazaki, S.; Nakamura, H.; Kusa, S.; Uchiyama, T.; Kakita, K.; Kakuta, T.; Hachiya, H.; Iesaka, Y. Impact of atrial fibrillation termination on clinical outcome after ablation in relation to the duration of persistent atrial fibrillation. PACE-Pacing Clin. Electrophysiol. 2012, 35, 1436–1443. [Google Scholar] [CrossRef] [PubMed]
- Gizurarson, S.; Dalvi, R.; Das, M.; Ha, A.C.T.; Suszko, A.; Chauhan, V.S. Hierarchical Schema for Identifying Focal Electrical Sources During Human Atrial Fibrillation. JACC Clin. Electrophysiol. 2016, 2, 656–666. [Google Scholar] [CrossRef] [PubMed]
- Seitz, J.; Bars, C.; Théodore, G.; Beurtheret, S.; Lellouche, N.; Bremondy, M.; Ferracci, A.; Faure, J.; Penaranda, G.; Yamazaki, M.; et al. AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein Isolation: A Wholly Patient-Tailored Approach. J. Am. Coll. Cardiol. 2017, 69, 303–321. [Google Scholar] [CrossRef] [PubMed]
- Nademanee, K.; McKenzie, J.; Kosar, E.; Schwab, M.; Sunsaneewitayakul, B.; Vasavakul, T.; Khunnawat, C.; Ngarmukos, T. A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate. J. Am. Coll. Cardiol. 2004, 43, 2044–2053. [Google Scholar] [CrossRef]
- Cervigón, R.; Moreno, J.; García-Quintanilla, J.; Pérez-Villacastín, J.; Castells, F. Entropy at the right atrium as a predictor of atrial fibrillation recurrence outcome after pulmonary vein ablation. Biomed. Eng.-Biomed. Tech. 2016, 61, 29–36. [Google Scholar] [CrossRef]
- Szilágyi, J.; Walters, T.E.; Marcus, G.M.; Vedantham, V.; Moss, J.D.; Badhwar, N.; Lee, B.; Lee, R.; Tseng, Z.H.; Gerstenfeld, E.P. Surface ECG and intracardiac spectral measures predict atrial fibrillation recurrence after catheter ablation. J. Cardiovasc. Electrophysiol. 2018, 29, 1371–1378. [Google Scholar] [CrossRef]
- Mukherjee, R.K.; Williams, S.E.; Niederer, S.A.; D O’Neill, M. Atrial Fibrillation Ablation in Patients with Heart Failure: One Size Does Not Fit All. AER. 2018, 7, 84. [Google Scholar] [CrossRef]
- Johner, N.; Namdar, M.; Shah, D.C. Individualised Approaches for Catheter Ablation of AF: Patient Selection and Procedural Endpoints. AER 2019, 8, 184–190. [Google Scholar] [CrossRef] [Green Version]
- Narayan, S.M.; Kazi, D.; Krummen, D.E.; Rappel, W.J. Repolarization and Activation Restitution Near Human Pulmonary Veins and Atrial Fibrillation Initiation. J. Am. Coll. Cardiol. 2008, 52, 1222–1230. [Google Scholar] [CrossRef] [PubMed]
- Masè, M.; Disertori, M.; Marini, M.; Ravelli, F. Characterization of rate and regularity of ventricular response during atrial tachyarrhythmias. Insight on atrial and nodal determinants. Physiol. Meas. 2017, 38, 800–818. [Google Scholar] [CrossRef] [PubMed]
- Cervigón, R.; Moreno, J.; Castells, F. Entropy Analysis of Atrial Activity Morphology to Study Atrial Fibrillation Recurrences after Ablation Procedure. In Bioinformatics and Biomedical Engineering. IWBBIO 2015. Lecture Notes in Computer Science; Ortuño, F., Rojas, I., Eds.; Springer: Berlin/Heidelberger, Germany, 2015; Volume 9043. [Google Scholar]
- Forclaz, A.; Narayan, S.M.; Scherr, D.; Linton, N.; Jadidi, A.S.; Nault, I.; Rivard, L.; Miyazaki, S.; Uldry, L.; Wright, M.; et al. Early temporal and spatial regularization of persistent atrial fibrillation predicts termination and arrhythmia-free outcome. Heart Rhythm 2011, 8, 1374–1382. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Cervigón, R.; Moreno, J.; Reilly, R.B.; Millet, J.; Pérez-Villacastín, J.; Castells, F. Entropy measurements in paroxysmal and persistent atrial fibrillation. Physiol. Meas. 2010, 31, 1011–1020. [Google Scholar] [CrossRef]
- Ganesan, A.N.; Kuklik, P.; Lau, D.H.; Brooks, A.G.; Baumert, M.; Lim, W.W.; Thanigaimani, S.; Nayyar, S.; Mahajan, R.; Kalman, J.M.; et al. Bipolar Electrogram Shannon Entropy at Sites of Rotational Activation: Implications for Ablation of Atrial Fibrillation. Circ.-Arrhythmia Electrophysiol. 2013, 6, 48–57. [Google Scholar] [CrossRef]
- Orozco-Duque, A.; Ugarte, J.P.; Tobon, C.; Saiz, J.; Bustamante, J. Approximate entropy can localize rotors, but not ectopic foci during chronic atrial fibrillation: A simulation study. Comput. Cardiol. 2013, 2013, 903–906. [Google Scholar]
- Acharya, U.R.; Faust, O.; Ciaccio, E.J.; Koh, J.E.W.; Oh, S.L.; Tan, R.S.; Garan, H. Application of nonlinear methods to discriminate fractionated electrograms in paroxysmal versus persistent atrial fibrillation. Comput. Meth. Programs Biomed. 2019, 175, 163–178. [Google Scholar] [CrossRef]
- Matsuo, S.; Lellouche, N.; Wright, M.; Bevilacqua, M.; Knecht, S.; Nault, I.; Lim, K.T.; Arantes, L.; O’Neill, M.D.; Platonov, P.G.; et al. Clinical Predictors of Termination and Clinical Outcome of Catheter Ablation for Persistent Atrial Fibrillation. J. Am. Coll. Cardiol. 2009, 54, 788–795. [Google Scholar] [CrossRef]
- Dibs, S.R.; Ng, J.; Arora, R.; Passman, R.S.; Kadish, A.H.; Goldberger, J.J. Spatiotemporal characterization of atrial activation in persistent human atrial fibrillation: Multisite electrogram analysis and surface electrocardiographic correlations—A pilot study. Heart Rhythm 2008, 5, 686–693. [Google Scholar] [CrossRef]
- Bunch, T.J.; Cutler, M.J. Is pulmonary vein isolation still the cornerstone in atrial fibrillation ablation? J. Thorac. Dis. 2015, 7, 10. [Google Scholar]
Method | p-Value | Area Under ROC | Sensitivity OPT ROC | Specificity OPT ROC | Value for OPT ROC |
---|---|---|---|---|---|
LZC | 0.010 | 0.76 | 0.70 | 0.81 | 75 |
BDM | 0.008 | 0.81 | 0.70 | 1.00 | 2076 |
ShanEn | 0.052 | 0.76 | 0.70 | 0.81 | 2.47 |
AFCL | 0.944 | 0.51 | -* | -* | -* |
DF | 0.665 | 0.56 | -* | -* | -* |
DF RI | 0.737 | 0.49 | -* | -* | -* |
DF OI | 0.084 | 0.34 | -* | -* | -* |
NavX CFAE | 0.876 | 0.60 | -* | -* | -* |
CEA | 0.481 | 0.51 | -* | -* | -* |
ICL | 0.813 | 0.55 | -* | -* | -* |
ACI | 0.484 | 0.42 | -* | -* | -* |
SCI | 0.293 | 0.57 | -* | -* | -* |
SampEn | 0.978 | 0.53 | -* | -* | -* |
WMS | 0.160 | 0.28 | -* | -* | -* |
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Stępień, K.; Kuklik, P.; Żebrowski, J.J.; Sanders, P.; Derejko, P.; Podziemski, P. Kolmogorov Complexity of Coronary Sinus Atrial Electrograms Before Ablation Predicts Termination of Atrial Fibrillation After Pulmonary Vein Isolation. Entropy 2019, 21, 970. https://doi.org/10.3390/e21100970
Stępień K, Kuklik P, Żebrowski JJ, Sanders P, Derejko P, Podziemski P. Kolmogorov Complexity of Coronary Sinus Atrial Electrograms Before Ablation Predicts Termination of Atrial Fibrillation After Pulmonary Vein Isolation. Entropy. 2019; 21(10):970. https://doi.org/10.3390/e21100970
Chicago/Turabian StyleStępień, Katarzyna, Pawel Kuklik, Jan J. Żebrowski, Prashanthan Sanders, Paweł Derejko, and Piotr Podziemski. 2019. "Kolmogorov Complexity of Coronary Sinus Atrial Electrograms Before Ablation Predicts Termination of Atrial Fibrillation After Pulmonary Vein Isolation" Entropy 21, no. 10: 970. https://doi.org/10.3390/e21100970
APA StyleStępień, K., Kuklik, P., Żebrowski, J. J., Sanders, P., Derejko, P., & Podziemski, P. (2019). Kolmogorov Complexity of Coronary Sinus Atrial Electrograms Before Ablation Predicts Termination of Atrial Fibrillation After Pulmonary Vein Isolation. Entropy, 21(10), 970. https://doi.org/10.3390/e21100970