Next Article in Journal
Heterogeneous Multi-Robot System for Mapping Environmental Variables of Greenhouses
Next Article in Special Issue
Capacitive Sensing for Non-Invasive Breathing and Heart Monitoring in Non-Restrained, Non-Sedated Laboratory Mice
Previous Article in Journal
A Novel Pre-Processing Technique for Original Feature Matrix of Electronic Nose Based on Supervised Locality Preserving Projections
Previous Article in Special Issue
Feature Selection Method Based on Neighborhood Relationships: Applications in EEG Signal Identification and Chinese Character Recognition
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG

Department of Biomedical Science and Engineering (BMSE), Institute of Integrated Technology (IIT), Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea
*
Author to whom correspondence should be addressed.
Sensors 2016, 16(7), 1020; https://doi.org/10.3390/s16071020
Submission received: 27 April 2016 / Revised: 24 June 2016 / Accepted: 29 June 2016 / Published: 1 July 2016
(This article belongs to the Special Issue Noninvasive Biomedical Sensors)

Abstract

:
Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR.

1. Introduction

Identification of fetal distress is important in fetal monitoring during pregnancy. A noninvasive fetal monitoring method for measuring the fetal heart rate (FHR) is essential to assess the health of a fetus [1]. Cardiotocography (CTG) and fetal electrocardiogram (ECG) are common methods for monitoring the FHR [2]. The Doppler ultrasonic technique measures the FHR from the fetal heart activity using the Doppler effect. However, fetal movements and the blood flow through the maternal blood vessels always influence the Doppler ultrasound signal [3]. As the ultrasound signal includes these influences, the R-peak detection of the FHR becomes very challenging. Moreover, the mother should maintain a reclining position for one hour while the FHR data is being collected. Therefore, this approach is not suitable for long term continuous monitoring [4].
Various techniques have been proposed to extract the fetal ECG from the abdominal ECG signals of pregnant women [5,6,7]. Long-term monitoring is possible using these techniques; currently, independent component analysis (ICA) and principle component analysis (PCA) has been applied to the maternal ECG signal from the abdomen to extract the fetal ECG [7]. However, multichannel data are required for the ICA. If the number of ECG signals from the maternal abdomen is insufficient, the pure fetal ECG signals cannot be extracted using ICA [8].
On the other hand, various FHR estimation methods have been developed for single-channel data in several studies [9,10,11,12]. The template subtraction (TS) method, in particular, was commonly used for removing the maternal ECG components and extracting the fetal ECG [9,10]. However, the residual signal after removing the maternal ECG is still affected by several artifacts. This makes it difficult to find the exact location of the fetal ECG R-peaks using the TS method. The extended Kalman filter (EKF) framework has shown good performance for the extraction of the FHR [11,12,13,14]; it focuses on the cancellation of the maternal ECG. However, this method cannot extract the R-peak of the fetal ECG if the residual signal after eliminating the maternal ECG has a low-amplitude fetal ECG. Furthermore, when the QRS complexes of the maternal ECG and fetal ECG overlap, the residual signal can lose the QRS-complex segment of the fetal ECG. Therefore, the EKF framework may miss the detection of the fetal R-peak. Another estimation method is the wavelet-based approach [15]. Wavelet analysis is a time-frequency decomposition approach that can simultaneously eliminate the baseline and the high-frequency noises from the abdominal ECG and then, efficiently detect the fetal R-peaks from the filtered abdominal ECG. Although the wavelet-based approach also shows satisfactory results, the R-peak of the fetal ECG cannot be detected from the noisy residual signals after cancelling the maternal ECG.
Recently, sparse representations for signal processing have been studied for noise reduction [16,17]. Total variation denoising (TVD) has been widely used to reduce noise in image processing [18]. This approach can preserve the sharp edges of the underlying signal. Recently, Ning et al. proposed sparse derivative denoising for ECG enhancement using TVD [19]. This method can be used as a preprocessing stage for ECG analysis.
In this paper, we propose a method for measuring the FHR from the single-channel abdominal ECG signal of a pregnant woman using sequential TVD (STVD). To extract the fetal ECG, we established an abdominal ECG model and then, TVD [18] was applied twice, sequentially. Recent advanced research provided a standard methodology for benchmarking of fetal ECG extraction methods [20,21]. We followed the testing methodology to evaluate our proposed method. The remainder of this paper is organized as follows. In Section 2, the proposed STVD algorithm is described. In Section 3, we compare the performance of this method with those of three other single-channel fetal-ECG-extraction methods including the EKF and TSPCA using simulation signals and real signals from medical databases [22]. To prove the importance of the second TVD step, a method in which TVD is applied only once to extract the fetal ECG, i.e., a combining TVD and TSPCA (TVD + TSPCA) is also compared with the proposed method. Finally, a discussion about the results of our proposed method and the conclusions are presented in Section 4.

2. Methods

2.1. Preprocessing

The abdominal ECG signal is usually contaminated by baseline wandering, electromyogram (EMG) noise, and power-line noise. We applied a third-order Butterworth band-pass filter with 3-Hz and 90-Hz cutoff frequencies to remove both the baseline wandering and EMG noise [10]. A 50 or 60-Hz notch filter was used to eliminate the power-line noise [10].

2.2. Proposed Method: Sequential TVD with TSPCA

The proposed algorithm consists of three steps. First, the abdominal ECG is filtered using TVD. Then, the maternal ECG is extracted from the abdominal ECG using the TSPCA method. Finally, TVD is applied again as a cascaded process to the residual signal for estimating the fetal ECG. Figure 1 briefly illustrates the processes in our proposed algorithm.

2.2.1. First TVD: Enhancing the Abdominal ECG

The maternal abdominal ECG signal y 1 is given by:
y 1 = x + e 1
where the vector x is a clean abdominal signal of length N and e 1 is the residual noise. y 1 is the contaminated measurement of x . The clean abdominal signal x is given by:
x = x M E C G + x F E C G
where the vectors xMECG and xFECG with N time points represent the maternal ECG and fetal ECG signals, respectively. x can be extracted using the TVD problem as follows:
x * = argmin x 1 2 y 1 x 2 + λ 1 D 2 x 1
where n is the n (n = 1, 2) norm in N (N: data length), the regularization parameter λ1 > 0, and D 2 is the second-order difference matrix. As the ECG can be approximated by piecewise linear function [18], D 2 makes the signal sparser. By increasing λ1, more weight is given to the second term that measures the fluctuation of the signal x. The second-order difference matrix is given by:
D 2 = [ 1 2 1 0 0 0 1 2 1 0 0 0 1 2 1 ]
In general, D 2 is a Toeplitz matrix of size ( N 2 ) × N .
To extract a clean abdominal ECG, Equation (3) must be solved. However, this optimization problem cannot be solved explicitly. The Majorization–Minimization (MM) algorithm is a method for finding the solution to the optimization problem [23]. A convex function Q ( x ) was minimized using iteration as follows:
Q ( x ) = 1 2 y 1 x 2 2 + λ 1 D 2 x 1
x ( i + 1 ) = arg min x L i ( x ) ,   i = 0 ,   1 ,   2 ,  
L i ( x ) should be a majorizer of Q ( x ) , that is,
L i ( x ) Q ( x ) ,   x ,
and L i ( x ) should satisfy Q ( x ) at x i ,
L i ( x i ) = Q ( x i )
where L i ( x ) and Q ( x i ) are a convex function. x i converged to the minimizer of Q ( x i ) by the MM algorithm. When L i ( x i ) coincide with Q ( x i ) at x i , x i + 1 can be obtained by the minimizing L i ( x ) using the MM approach. Finally, we can solve the minimization problem. The MM algorithm is briefly summarized as follows:
  • Set i = 0, initialize x 0 .
  • Choose Li(x) such that
    (1)
    L i ( x ) Q ( x ) , for all x
    (2)
    L i ( x i ) = Q ( x i )
  • Set x i + 1 as the minimizer of L i ( x ) ,
  • Set i = i + 1 and go back to step 2.

2.2.2. TSPCA: Elimination of Maternal ECG

Several TS methods were implemented for the extraction of fetal ECG. Locating the maternal QRS complexes is necessary to remove the maternal ECG using TS. In this study, TSPCA method was used since this showed better performance than other TS methods in the previous study [10,19]. TSPCA is described in the TSPCA section (see Section 2.3.3).

2.2.3. Second TVD: Extracting Fetal ECG

After removing the maternal ECG segments from the abdominal ECG, we can obtain the fetal ECG signal from the residual signal. However, the fetal ECG signal will still contain the maternal ECG and noise components. Hence, additional TVD is applied to the residual signal to enhance the fetal ECG signal as shown below:
y 2 = x F E C G + e 2
x F E C G * = argmin x F E C G 1 2 y 2 x F E C G 2 + λ 2 D 2 x F E C G 1
where the vector e 2 represents the residual artifacts including remains of the maternal ECG and noise. The same optimization process, which uses the MM approach to solve the TVD problem, is repeated. Finally, the fetal ECG R-peaks are detected from the final estimated fetal ECG.

2.3. Methods for Comparison

2.3.1. Extended Kalman Filter

The EKF is the nonlinear version of the standard Kalman filter. When we consider a discrete-time nonlinear system with the state vector p k and measurement vector q k at time instant k, this model is written with nonlinear functions f ( ) and h ( ) :
{ p k + 1 = f ( p k , w k ) q k + 1 = h ( p k + 1 , v k + 1 )
where the random variables w k and v k correspond to the process and measurement noises vectors, related to the process noise covariance Q and measurement noise covariance R, respectively. In this paper, we used a synthetic dynamic ECG model [24] to extract fetal ECG from the abdominal ECG [11,12,13,14]. One heartbeat ECG cycle is generally represented by the letters P, Q, R, S, and T. We used five Gaussian functions to establish one ECG signal model defined by peak amplitude ( α i ), width ( b i ), and each center of Gaussian function ( ξ i ) with respect to the PQRST sub-waveform [13]. The index i represents the number of Gaussian function. p k is defined by θ k and z k : p k = [ θ k , z k ] T , where θ k and z k are phase and amplitude of the maternal ECG at time instant k. The state equation can describe the ECG nonlinear dynamics such as the PQRST morphology by assuming a small sampling period δ and w k = [ 0 , η k ] T as follows:
f ( p k , w k ) { θ k + 1 = ( θ k + ω δ ) mod ( 2 π ) z k + 1 = z k + η k i { P , Q , R , S , T } δ α i ω b i 2 ( θ k ξ i ) exp ( ( θ k ξ i ) 2 2 b i 2 )
where η k is a random additive noise. Here, the phase θ k is used as an additional observation [13]. The R-peak of ECG is set to be located at θ k = 0 , and the ECG segments between two consecutive R-peaks are assumed to have a phase between 0 and 2π [13]. Consequentially, the observed phase φ k can be determined by detected R-peaks through φ k + 1 = θ k + 1 + u k + 1 . q k + 1 = h ( p k + 1 , v k + 1 ) is finally expressed as q k + 1 = p k + 1 + v k + 1 , where q k + 1 = [ φ k + 1 , s k + 1 ] T and v k + 1 = [ u k + 1 , v k + 1 ] T with s k + 1 = z k + 1 + v k + 1 . s k + 1 represents the observed amplitude. The maternal ECGs can be estimated by consecutive EKF steps. The first EKF extracts the maternal ECG from the abdominal ECG. After subtracting the maternal ECG from the abdominal ECG, the second EKF estimate fetal ECG from the residual signal.

2.3.2. TVD + TSPCA

The process of the TVD + TSPCA is similar to the STVD method. This approach first filters the abdominal ECG signal using TVD and then applies TSPCA to filtered abdominal ECG signal to eliminate the maternal ECG. After applying TSPCA, fetal R-peak detection is performed on the residual signal. In the TVD + TSPCA, λ was set to the same value as the λ1 in the STVD approach.

2.3.3. TSPCA

TSPCA was introduced by Kanjilal et al. [25]. The design matrix X was built with several rows in which each row corresponds to one maternal ECG cycle with all R-peaks lying at the same column as follows:
X = [ x 11 x 1 n x m 1 x m n ]
where m and n represents the number of maternal ECG cycles and sample sizes. The principle components (PCs) of X can be obtained using singular value decomposition. The PCs related to maternal ECG can be subtracted from the overall cycles as follows:
X r = X j = 1 p w j w j T X
where p is the number of PCs and w j is the direction vector of the j-th PC. The residual signal X r is then the fetal ECG. This method needs to update the design matrix.

2.4. Data

There is no standard tool for the evaluation of the single-channel fetal ECG recording [11]; simulations are required to provide quantitative assessments for the proposed method. The fecgsyn, a non-invasive fetal ECG model simulator [26], can generate several types of maternal and fetal ECG mixed signals. Recently, Andreotti et al. developed the Fetal ECG Synthetic Database (FECGSYNDB) using the fecgsyn for benchmarking of fetal ECG extraction and detection algorithms [20]. This database includes 1750 realistic simulated abdominal ECG signal with 34 channels (2 channels: maternal ECG, 32 channels: abdominal ECG), generated at a 250 Hz sampling frequency for 5 min. The simulation signals were divided into seven cases with five signal-to-noise ratio (SNR) levels (0, 3, 6, 9 and 12 dB) and 10 different maternal and fetal heart dipole’s arrangements. Each simulation signal was generated five times for statistical purposes. Table 1 represents several cases of simulation signal. A recent work selected 8 channels (1, 8, 11, 14, 19, 22, 25 and 32) among 34 channels for evaluating algorithms [20]. We also used the same channels.
Figure 2a shows the simulated maternal ECG. The fetal ECG was also constructed using the simulator (Figure 2b). The simulated fetal ECG was added to the simulated maternal ECG along with motion and EMG artifacts produced by the simulator to generate the final simulated signal (Figure 2c). To verify the efficiency of the proposed method on real data, we used PhysioNet fetal ECG databases with varying SNRs [10,21]. The database is the 2013 PhysioNet/Computing in Cardiology Challenge Database (PCDB) [22]. PCDB consisted of three data sets (set-a, set-b and set-c). We used set-a for the assessment of extraction algorithms since reference fetal QRS locations were offered. This database contained 1-min abdominal ECGs from four abdominal ECG channels at 1000 Hz. This database includes 75 datasets. However, records a33, a38, a47, a52, a54, a71, and a74 have inaccurate fetal QRS annotations. Therefore, we excluded these data and used a total of 68 datasets.
For the best channel selection, we used beat comparison measure (BCM) in each database [10]. BCM scans the maternal QRS position already removed along the residual signal, and then selects the channel in which the amplitudes of maternal QRS segments are the lowest. After selecting the best channel, the extraction fetal ECG procedure was performed. When EKF and TSPCA were applied for the extraction of fetal ECG, we used open-source code in the FECGSYN toolbox [26].

2.5. Evaluation and Detection of Fetal ECG R-Peak

To analyze the simulation results, we detected the fetal ECG R-peaks to compare the four techniques according to the sensitivity (Se), positive predictive value (PPV) and the F1-measure. The formulae for Se, PPV, and F1 are as follows [20]:
S e = T P T P + F N
P P V = T P T P + F P
F 1 = 2 P P V S e P P V + S e = 2 T P 2 T P + F N + F P
where TP, FP, and FN denote the true positive rate, false positive rate, and false negative rate, respectively. TP indicates that true fetal ECG R-peaks were detected. FP indicates that an artifact was detected as a true fetal ECG R-peak, while FN indicates false R-peak misdetection. In addition, Se indicates the ability to detect the R-peak, and PPV provides the probability that the true fetal ECG R-peaks are detected. F1 indicates the overall probability that the fetal ECG R-peaks are detected correctly. The acceptance interval between detection and reference location of fetal R-peak was defined to be ±50 ms [10,20]. For fetal R-peak detection, many detection algorithms were offered as open-sources. Since the detection performance varies depending on algorithms, we selected the adapted version of the Pan and Tompkins algorithm which is commonly used for ECG R-peak detection [10,20]. The FECGSYN toolbox also includes this source code. Moreover, the mean absolute error (MAE) of the absolute time difference between the reference fetal R-peak location and detected fetal R-peak location was calculated to compare the four methods—STVD, EKF, TVD + TSPCA, and TSPCA, in diverse situations. MAE is expressed as:
M A E = 1 N T P i = 1 N T P | a i a ^ i |
where a i and a ^ i are the reference R-peak time location and detected R-peak time location. NTP is the total number of TP.

3. Results

3.1. Parameter Optimization

Grid search was performed to find optimal parameters for STVD and EKF. On the other hand, we chose the number of maternal ECG cycles with the highest F1 to build the maternal ECG template for TSPCA. Figure 3 shows heat map and performance change with different numbers of maternal ECG cycles for each database (simulation: FECGSYNDB, real data: set-a). In this study, we multiplied covariance matrix Q and R by their gains to obtain the best performance for EFK [10]. Two gains were denoted as GQ and GR, respectively. We found optimized GQ and GR values using grid search. In TSPCA case, the number of PCs and the number of maternal ECG cycles influence on the performance of TSPCA. When the number of PCs was set to 2, we got the best result for all databases. Therefore, we searched for only the optimal number of maternal ECG cycles. Table 2 illustrates optimal parameters of each algorithm for different databases. For set-a, optimal parameters of EKF and TSPCA had the same values as previous work [10].

3.2. Simulation

Realistic simulated signals were used to assess the performance of the STVD method for comparison with the performances of the other methods. The extraction of the fetal ECG signals by several algorithms is shown in Figure 4. As shown in Figure 4, the fetal ECG signals extracted by TVD + TSPCA and TSPCA are still influenced by artifacts. That is, as TVD + TSPCA and TSPCA had considerable amounts of remaining noise, it was difficult to find the exact R-peak (see red boxes in Figure 4). Moreover, the EKF could not extract the R-peaks of the fetal ECG occasionally (see red circles in Figure 4). However, the STVD method could extract all R-peaks accurately in Figure 4.
Table 3 and Table 4 show various results for evaluating the performance of each algorithm. The STVD method performs much better than other three algorithms with higher F1 for all cases. Especially, STVD has the highest F1 in uterine contraction (case 3) and ectopic beats (case 4) cases. However, the MAE results of STVD are higher than EKF method (STVD: 3.9 ms, EKF: 3.8 ms).
Figure 5 shows results of F1 after applying noninvasive fetal ECG extraction methods in various cases with different SNR levels. We used a Kruskal-Wallis test to identify a significant effect of the SNR [19]. In particular, this test was meant to determine whether there is a statistically significant difference of F1 value according to different SNR levels. If p-values are smaller than 0.05, it means that the performance of extraction methods is influenced by SNR levels. As shown in Figure 5, EKF, TVD + TSPCA, and TSPCA are vulnerable to high noise levels (p < 0.05), while STVD shows significant noise robustness as in case 3, 4, and 5. Furthermore, we performed a post hoc analysis using Sign test for the assessment of paired differences between fetal ECG extraction methods (see Figure 6) [20]. Since the significant differences could not be identified, we excluded plots for SNR 9 and 12 dB in Figure 6. Figure 6 illustrates that results of STVD are significantly different from other methods for low SNR 0 and 3 dB (p < 0.05).

3.3. PhysioNet Database

STVD was also applied to PhysioNet databases, and the estimated fetal ECG signals for set-a are shown in Figure 7. As shown in Figure 7c, the EKF might remove the fetal ECG from set-a dataset (see red circle). Moreover, the residual signals of the TVD + TSPCA and TSPCA methods are still influenced by artifacts (see Figure 7d,e). Meanwhile, we have confirmed from the set-a data that our proposed method can extract the fetal ECG accurately (see Figure 7b). Table 5 presents the results of the comparison of our proposed method with the other three methods for set-a. STVD presents higher F1 scores (F1: 89.9%) than the other methods (EKF: 81.1%, TVD + TSPCA: 87.4%, TSPCA: 86.7%). Moreover, this dataset generally has lower SNR; hence, TVD + TSPCA and TSPCA showed worse performances than STVD. In addition, the time–frequency presentation using the Stockwell-transform [27] in Figure 8 demonstrates that the EKF could extract the fetal ECG for set-a. However, we can confirm from Figure 8 that the EKF might detect incorrect fetal ECG R-peaks (see red arrows). Only the STVD could extract all the R-peaks of the fetal ECGs exactly in Figure 8. As can be observed in Figure 8, the spectral content of artifacts still remains in the fetal ECG signal extracted via TVD + TSPCA and TSPCA, while STVD could isolate the spectral contents in the fetal ECG.

4. Discussion and Conclusions

In this paper, we proposed sequential total variation denoising (STVD) for fetal electrocardiogram (ECG) extraction from the abdominal ECGs of pregnant women. In this method, two total variation denoising (TVD) steps were used sequentially. The first TVD reduced the noise components of the abdominal ECG for effective cancellation of the maternal ECG by template subtraction (TSPCA) and then the second TVD enhanced the fetal ECG component. The extended Kalman filter (EKF) framework [11,12,13,14], TSPCA [10], and combined TVD with TSPCA (TVD + TSPCA) methods were compared with our proposed method. TSPCA has been widely used for extracting the fetal ECG from single-channel abdominal ECGs. However, the results from simulation and real datasets showed that the TSPCA method was not suitable for noisy abdominal ECGs. The performance of the TSPCA approach heavily depends on accurate detection of maternal ECG R-peaks. When accurate maternal R-peak cannot be detected because of noise, the TSPCA method cannot remove maternal ECG segments. Thus, TSPCA showed poor performance for low SNR levels in the simulation. Moreover, the residual signal, after extracting the maternal ECG from the noisy abdominal ECG using TSPCA, was still noisy; this makes it difficult to confirm the fetal ECG.
Recently, several studies have employed the EKF framework to extract the fetal ECG [11,12,13,14] as the EKF demonstrates good performance. The drawbacks of the EKF framework were shown by the simulation and real dataset. When the R-peaks of the fetal ECG and maternal ECG overlapped, it was difficult for the EKF to distinguish the fetal ECG from the maternal ECG (see Figure 4 and Figure 8) [11]. Therefore, the fetal ECG was also eliminated during the maternal ECG cancellation. Furthermore, if the amplitude of the fetal ECG was small, this method could not detect the true fetal ECG peaks (see Figure 7). As the EKF framework requires strong assumptions to establish a dynamic model, it requires reliable prior information about the fetal ECG R-peaks [28]. The EKF method showed worse performance than all other approaches for simulation and a real dataset (see Table 3 and Table 5). As the EKF approach removed the fetal ECG R-peak during the process of maternal ECG cancellation, the number of FNs increased for the two real datasets. Meanwhile, STVD could detect true fetal ECG R-peaks correctly because of the fetal ECG enhancement by the additional TVD step [18]. Therefore, STVD had higher Se values than other methods. However, EKF had the best results for MAE. This is because that EKF method estimated fetal ECG R-peaks using prior information about the fetal ECG R-peaks. On the other hand, the morphology of fetal ECG was distorted by TVD, even though STVD performed better to extract fetal ECG R-peaks from single-channel abdominal ECG. Figure 9 shows the morphological changes of fetal ECG extracted using STVD with different values of λ2. We can confirm from Figure 9 that the amplitude of PQRST waves was reduced by the TVD method. Furthermore, location of fetal R-peaks was also distorted. Therefore, MAE results of STVD had higher than EKF. However, if we can find suitable regularization parameters, STVD can extract fetal ECG with minimal fetal ECG signal distortion (See Figure 9).
Finally, to verify the importance of the second TVD step, we compared STVD with the combination of TVD and TSPCA. As shown in Table 3 and Table 4, TVD + TSPCA showed better performance than TSPCA, since the TVD step could enhance the abdominal ECG. After the cancellation of the maternal ECG segments, the residual signal was less influenced by artifacts than the residual signal produced by the TSPCA method. However, TVD + TSPCA could not enhance the fetal ECG adequately because of its residual noise. In contrast, the STVD method could extract the fetal ECG by means of a second TVD step. The ECG waveform generally includes spike peaks. We could establish the ECG model as an approximate piecewise linear model. As the ℓ1 norm term of the TVD problem measures the fluctuation of the signal, TVD could preserve the signal with high total variation, such as a QRS complex. This characteristic enhanced the fetal ECG R-peaks [19,29]. Thus, STVD showed much better performance than the TVD + TSPCA for both simulations and real data. Moreover, the F1 of STVD was higher than that of TVD + TSPCA. Overall, STVD could effectively detect true fetal ECG R-peaks and decrease the error rate of detection. Altogether, the results of this study suggest that the STVD is a promising tool for monitoring the FHR using single-channel abdominal ECGs of pregnant women. Therefore, our proposed method would help in the continuous detection of changes in the normal FHR pattern. Moreover, one of the issues for FHR monitoring is the real-time implementation. Since we already recognized low computational load in our approach, we plan to develop a real-time FHR monitoring system for future work.

Acknowledgments

This work was supported by the GIST Research Institute (GRI) in 2016, and by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2014R1A1A2057801).

Author Contributions

Kwang Jin Lee drafted the manuscript, developed the source code, and processed the abdominal ECG data. Boreom Lee supervised the entire research process and revised the manuscript. Both authors contributed to the research design, result interpretation, and proofreading of the final manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
FHRFetal Heart Rate
ECGElectrocardiograms
STVDSequential total variation denoising
TVDTotal variation denoising
ICAIndependent component analysis
PCAPrinciple component analysis
TSTemplate subtraction
EKFExtended Kalman filter
MAEMean absolute error
SeSensitivity
PPVPositive predictive value
SNRSignal-to-noise ratio

References

  1. Parer, J.T. Handbook of Fetal Heart Rate Monitoring; W. B. Saunders Company: Philadelphia, PA, USA, 1997. [Google Scholar]
  2. Peters, M.; Crowe, J.; Piéri, J.-F.; Quartero, H.; Hayes-Gill, B.; James, D.; Stinstra, J.; Shakespeare, S. Monitoring the fetal heart non-invasively: A review of methods. J. Perinat. Med. 2005, 29, 408–416. [Google Scholar] [CrossRef] [PubMed]
  3. Jezewski, J.; Roj, D.; Wrobel, J.; Horoba, K. A novel technique for fetal heart rate estimation from Doppler ultrasound signal. Biomed. Eng. Online. 2011, 10. [Google Scholar] [CrossRef] [PubMed]
  4. Ibrahimy, M.I.; Ahmed, F.; Ali, M.A.M.; Zahedi, E. Real-time signal processing for fetal heart rate monitoring. IEEE Trans. Biomed. Eng. 2003, 50, 258–261. [Google Scholar] [CrossRef] [PubMed]
  5. Assaleh, K.; Al-Nashash, H. A novel technique for the extraction of fetal ECG using polynomial networks. IEEE Trans. Biomed. Eng. 2005, 52, 1148–1152. [Google Scholar] [CrossRef] [PubMed]
  6. Wua, S.; Shen, Y.; Zhou, Z.; Lin, L.; Zeng, Y.; Gao, X. Research of fetal ECG extraction using wavelet analysis and adaptive filtering. Comput. Biol. Med. 2013, 43, 1622–1627. [Google Scholar] [CrossRef] [PubMed]
  7. Lathauwer, L.; De Moor, B.; Vandewalle, J. Fetal electrocardiogram extraction by blind source subspace separation. IEEE Trans. Biomed. Eng. 2000, 47, 567–572. [Google Scholar] [CrossRef] [PubMed]
  8. Hyvärinen, A.; Karhunen, J.; Oja, E. Independent Component Analysis; Wiley: New York, NY, USA, 2001. [Google Scholar]
  9. Podziemski, P.; Gieraltowski, J. Fetal heart rate discovery: algorithm for detection of fetal heart rate from noisy, noninvasive fetal ECG recordings. In Proceedings of the 2013 Computing in Cardiology Conference (CinC), Zaragoza, Spain, 22–25 September 2013; pp. 333–336.
  10. Behar, J.; Oster, J.; Clifford, G.D. Combining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data. Physiol. Meas. 2014, 35. [Google Scholar] [CrossRef] [PubMed]
  11. Niknazar, M.; Rivet, B.; Jutten, C. Fetal ECG extraction by extended state Kalman filtering based on single-channel recordings. IEEE Trans. Biomed. Eng. 2013, 60, 1345–1352. [Google Scholar] [CrossRef] [PubMed]
  12. Akhbari, M.; Niknazar, M.; Jutten, C.; Shamsollahi, M.B.; Rivet, B. Fetal electrocardiogram R-peak detection using robust tensor decomposition and extended Kalman filtering. In Proceedings of the 2013 Computing in Cardiology Conference (CinC), Zaragoza, Spain, 22–25 September 2013; pp. 189–192.
  13. Sameni, R. Extraction of Fetal Cardiac Signals from an Array of Maternal Abdominal Recordings. Ph.D. Thesis, Sharif University of Technology, Tehran, Iran, 2008. [Google Scholar]
  14. Andreotti, F.; Riedl, M.; Himmelsbach, T.; Wedekind, D.; Zaunseder, S.; Wessel, N.; Malberg, H. Maternal signal estimation by Kalman filtering and template adaptation for fetal heart rate extraction. In Proceedings of the 2013 Computing in Cardiology Conference (CinC), Zaragoza, Spain, 22–25 September 2013; pp. 193–196.
  15. Castillo, E.; Morales, D.P.; Botella, G.; García, A.; Parrilla, L.; Palma, A.J. Efficient wavelet-based ECG processing for single-lead FHR extraction. Digit. Signal Prog. 2013, 23, 1897–1909. [Google Scholar] [CrossRef]
  16. Tibshirani, R. Regression shrinkage and selection via the LASSO. J. R. Stat. Soc. Ser. B 2008, 58, 267–288. [Google Scholar]
  17. Chen, S.S.; Donoho, D.L.; Saunders, A.M. Atomic decomposition by basispursuit. SIAM J. Sci. Comput. 1998, 20, 33–61. [Google Scholar] [CrossRef]
  18. Rudin, L.I.; Osher, S.; Fatemi, E. Nonlinear total variation based noise removal algorithms. Phys. D Nonlinear Phenom. 1992, 60, 259–268. [Google Scholar] [CrossRef]
  19. Ning, X.R.; Selesnick, I.W. ECG enhancement and QRS detection based on Sparse derivatives. Biomed. Signal Process. Control 2013, 8, 713–723. [Google Scholar] [CrossRef]
  20. Andreotti, F.; Behar, J.; Zaunseder, S.; Oster, J.; Clifford, G.D. An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms. Physiol. Meas. 2016, 37, 627. [Google Scholar] [CrossRef] [PubMed]
  21. Behar, J.; Andreotti, F.; Zaunseder, S.; Oster, J.; Clifford, G.D. A practical guide to non-invasive foetal electrocardiogram extraction and analysis. Physiol. Meas. 2016, 37. [Google Scholar] [CrossRef]
  22. Silva, I.; Behar, J.; Sameni, R.; Zhu, T.; Oster, J.; Clifford, G.D.; Moody, G.B. Noninvasive fetal ECG: The physionet/computing in cardiology challenge 2013. In Proceedings of the IEEE In Computing in Cardiology Conference (CinC), Zaragoza, Spain, 22–25 September 2013; pp. 149–152.
  23. Figueiredo, M.A.; Bioucas-Dias, J.M.; Nowak, R.D. Majorization-minimization algorithms for wavelet-based image restoration. IEEE Trans. Image Process. 2007, 16, 2980–2991. [Google Scholar] [CrossRef] [PubMed]
  24. McSharry, P.E.; Clifford, G.D.; Tarassenko, L.; Smith, L.A. A dynamical model for generating synthetic electrocardiogram signals. IEEE Trans. Biomed. Eng. 2003, 50, 289–294. [Google Scholar] [CrossRef] [PubMed]
  25. Kanjilal, P.P.; Palit, S.; Saha, G. Fetal ECG extraction from single-channel maternal ECG using singular value decomposition. IEEE Trans. Biomed. Eng. 1997, 44, 51–59. [Google Scholar] [CrossRef] [PubMed]
  26. Behar, J.; Andreotti, F.; Zaunseder, S.; Li, Q.; Oster, J.; Clifford, G.D. An ECG simulator for generating maternal-foetal activity mixtures on abdominal ECG recordings. Physiol. Meas. 2014, 35, 1537. [Google Scholar] [CrossRef] [PubMed]
  27. Das, M.K.; Ari, S. Analysis of ECG signal denoising method based on S-transform. IRBM 2013, 34, 362–370. [Google Scholar] [CrossRef]
  28. Niknazar, M.; Rivet, B.; Jutten, C. Fetal ECG extraction from a single sensor by a non-parametric modeling. In Proceedings of the 20th European Signal Processing Conference (EUSIPCO), Bucharest, Romania, 27–31 August 2012; pp. 949–953.
  29. Pant, J.; Krishnan, S. Reconstruction of ECG signals for compressive sensing by promoting sparsity on the gradient. In Proceedings of the IEEE International Conference on In Acoustics, Speech and Signal Processing (ICASSP), Vancouver, BC, Canada, 26–31 May 2013; pp. 993–997.
Figure 1. Block diagram of STVD to extract the fetal ECG from single-channel abdominal ECG.
Figure 1. Block diagram of STVD to extract the fetal ECG from single-channel abdominal ECG.
Sensors 16 01020 g001
Figure 2. Simulated abdominal ECG using the fecgsyn. (a) Simulated maternal ECG; (b) Simulated fetal ECG; (c) Simulated abdominal ECG mixed with fetal ECG and artifacts.
Figure 2. Simulated abdominal ECG using the fecgsyn. (a) Simulated maternal ECG; (b) Simulated fetal ECG; (c) Simulated abdominal ECG mixed with fetal ECG and artifacts.
Sensors 16 01020 g002
Figure 3. Optimal parameters search performed according to F1. (a) FECGSYNDB (0 dB); (b) set-a database.
Figure 3. Optimal parameters search performed according to F1. (a) FECGSYNDB (0 dB); (b) set-a database.
Sensors 16 01020 g003
Figure 4. Extracting fetal ECG from the simulated abdominal ECG signal using four different methods. EKF sometimes eliminates the R-peaks of fetal ECG (red circles). Considerable noise remains after the extraction of fetal ECG by TVD + TSPCA and TSPCA methods (red boxes).
Figure 4. Extracting fetal ECG from the simulated abdominal ECG signal using four different methods. EKF sometimes eliminates the R-peaks of fetal ECG (red circles). Considerable noise remains after the extraction of fetal ECG by TVD + TSPCA and TSPCA methods (red boxes).
Sensors 16 01020 g004
Figure 5. Comparison of F1 results obtained from STVD, EKF, TVD + TSPCA, and TSPCA for each case. One case includes five box plots, one for each SNR level (0, 3, 6, 9, 12 dB); * indicates p < 0.05, and B is baseline. C0–C5 means 5 cases in Table 1.
Figure 5. Comparison of F1 results obtained from STVD, EKF, TVD + TSPCA, and TSPCA for each case. One case includes five box plots, one for each SNR level (0, 3, 6, 9, 12 dB); * indicates p < 0.05, and B is baseline. C0–C5 means 5 cases in Table 1.
Sensors 16 01020 g005
Figure 6. Results of the post hoc analysis using the Sign test over single-channel fetal ECG extraction methods. The post hoc analysis was performed regarding F1. Black square refers to significant differences (p < 0.05) and white means that there is no significant difference (p > 0.05). Results of SNR 9 and 12 dB are excluded because of no significant differences across methods.
Figure 6. Results of the post hoc analysis using the Sign test over single-channel fetal ECG extraction methods. The post hoc analysis was performed regarding F1. Black square refers to significant differences (p < 0.05) and white means that there is no significant difference (p > 0.05). Results of SNR 9 and 12 dB are excluded because of no significant differences across methods.
Sensors 16 01020 g006
Figure 7. Comparison of fetal ECG extraction by STVD, EKF, TVD + TSPCA and TSPCA using set-a (data ‘a12’). The EKF might lose the R-peak of the fetal ECG (red circle). Red cross indicates reference fetal QRS locations (a) Raw Signal; (b) STVD; (c) EKF; (d) TVD + TSPCA; (e) TSPCA.
Figure 7. Comparison of fetal ECG extraction by STVD, EKF, TVD + TSPCA and TSPCA using set-a (data ‘a12’). The EKF might lose the R-peak of the fetal ECG (red circle). Red cross indicates reference fetal QRS locations (a) Raw Signal; (b) STVD; (c) EKF; (d) TVD + TSPCA; (e) TSPCA.
Sensors 16 01020 g007
Figure 8. Time-frequency representation of extracted fetal ECG using the four different methods for data ‘a01’ from set-a. EKF could not detect the fetal ECG several times (red arrows). TVD + TSPCA and TSPCA still contain the spectral contents of artifacts (red boxes).
Figure 8. Time-frequency representation of extracted fetal ECG using the four different methods for data ‘a01’ from set-a. EKF could not detect the fetal ECG several times (red arrows). TVD + TSPCA and TSPCA still contain the spectral contents of artifacts (red boxes).
Sensors 16 01020 g008
Figure 9. Morphological changes of the STVD extracted fetal ECG according to λ2 for simulation data ‘sub01_snr09dB_l1_c0’.
Figure 9. Morphological changes of the STVD extracted fetal ECG according to λ2 for simulation data ‘sub01_snr09dB_l1_c0’.
Sensors 16 01020 g009
Table 1. Generating simulation signal for seven different physiological events.
Table 1. Generating simulation signal for seven different physiological events.
CaseDescription
Baseline (B)Abdominal ECG without any noise or events (maternal ECG + fetal ECG)
Case 0 (C0)Baseline (no events) + noise
Case 1 (C1)Fetal movement noise + noise
Case 2 (C2)Acceleration or deceleration of maternal and fetal heart rate + noise
Case 3 (C3)Uterine contraction + noise
Case 4 (C4)Ectopic beats of maternal and fetal + noise
Case 5 (C5)Twin + noise
Noise includes maternal movement and EMG artifacts.
Table 2. Optimal parameters of each extraction method for different databases.
Table 2. Optimal parameters of each extraction method for different databases.
MethodParametersFECGSYNDBSet-a
0 dB3 dB6 dB9 dB12 dB
STVDλ134124114
λ21692113
EKFGQ1052115
GR84751011100
TSPCAThe number of maternal ECG cycles232315141420
Table 3. Evaluation results on F1 for FECGSYNDB, shown as median (interquartile range, %).
Table 3. Evaluation results on F1 for FECGSYNDB, shown as median (interquartile range, %).
MethodBaselineCase 0Case 1Case 2Case 3Case 4Case 5Total
STVD100 (0.0)98.4 (4.3)99.4 (8.9)98.5 (9.5)80.2 (11.5)90.6 (5.9)97.5 (4.2)97.2 (9.9)
EKF100 (0.2)98.1 (9.9)98.8 (8.2)98.2 (9.6)77.8 (10.0)83.4 (7.3)94.5 (24.8)94.5 (19.8)
TVD + TSPCA100 (0.0)97.8 (8.7)99.4 (5.1)98.1 (8.0)78.7 (10.2)88.6 (17.2)95.9 (16.8)96.1 (24.8)
TSPCA100 (0.0)98.3 (9.9)99.2 (7.6)98.7 (9.3)77.5 (10.2)88.4 (10.8)94.9 (23.2)96 (18.5)
Table 4. Evaluation results on MAE for FECGSYNDB shown as median (interquartile range, ms).
Table 4. Evaluation results on MAE for FECGSYNDB shown as median (interquartile range, ms).
MethodBaselineCase 0Case 1Case 2Case 3Case 4Case 5Total
STVD3.3 (2.0)3.6 (1.9)3.7 (0.2)3.2 (1.3)4.5 (0.4)3.2 (3.6)3.3 (3.5)3.9 (2.2)
EKF4.5 (6.3)3.8 (4.4)3.1 (0.9)3.1 (1.1)3.9 (1.6)4.8 (1.4)3.5 (3.7)3.8 (2.7)
TVD + TSPCA3.4 (3.6)5.2 (3.5)5.1 (2.8)5.5 (3.3)4.2 (3.6)3.4 (2.0)3.8 (2.7)4.2 (2.1)
TSPCA4 (2.0)4.2 (2.1)4.2 (0.6)4.1 (0.8)4.7 (1.1)5.6 (0.8)4.3 (1.8)4.4 (1.6)
Table 5. Evaluation results on fetal R-peak detection for set-a.
Table 5. Evaluation results on fetal R-peak detection for set-a.
MethodTPFNFPSe (%)PPV (%)F1 (%)MAE (ms)
STVD9162946107290.589.489.99.3
EKF79891719198482.280.181.17.9
TVD + TSPCA85191189124687.787.287.416.4
TSPCA84751233136787.286.186.714.3
Total 68 datasets were used (record a33, a38, a47, a52, a54, a71, and a74 were excluded).

Share and Cite

MDPI and ACS Style

Lee, K.J.; Lee, B. Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG. Sensors 2016, 16, 1020. https://doi.org/10.3390/s16071020

AMA Style

Lee KJ, Lee B. Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG. Sensors. 2016; 16(7):1020. https://doi.org/10.3390/s16071020

Chicago/Turabian Style

Lee, Kwang Jin, and Boreom Lee. 2016. "Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG" Sensors 16, no. 7: 1020. https://doi.org/10.3390/s16071020

APA Style

Lee, K. J., & Lee, B. (2016). Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG. Sensors, 16(7), 1020. https://doi.org/10.3390/s16071020

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.