Next Article in Journal
Remote Sensing of Urban Microclimate Change in L’Aquila City (Italy) after Post-Earthquake Depopulation in an Open Source GIS Environment
Previous Article in Journal
Non-Dispersive Infrared Sensor for Online Condition Monitoring of Gearbox Oil
Previous Article in Special Issue
Hierarchical NiCo2O4 Hollow Sphere as a Peroxidase Mimetic for Colorimetric Detection of H2O2 and Glucose
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Biocompatible Colorimetric Triphenylamine- Dicyanovinyl Conjugated Fluorescent Probe for Selective and Sensitive Detection of Cyanide Ion in Aqueous Media and Living Cells

1
Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu 610041, China
2
University of Chinese Academy of Sciences, Beijing 100049, China
3
Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center, Chengdu 610041, China
*
Authors to whom correspondence should be addressed.
Sensors 2017, 17(2), 405; https://doi.org/10.3390/s17020405
Submission received: 12 December 2016 / Revised: 16 January 2017 / Accepted: 4 February 2017 / Published: 19 February 2017
(This article belongs to the Special Issue Colorimetric and Fluorescent Sensor)

Abstract

:
A colorimetric and turn-on fluorescent probe 1 bearing triphenylamine-thiophene and dicyanovinyl groups has been synthesized and used to detect cyanide anion via a nucleophilic addition reaction. Probe 1 exhibited prominent selectivity and sensitivity towards CN in aqueous media, even in the presence of other anions such as S2−, HS, SO32−, S2O32−, S2O82−, I, Br, Cl, F, NO2, N3, SO42−, SCN, HCO3, CO32− and AcO. Moreover, a low detection limit (LOD, 51 nM) was observed. In addition, good cell membrane permeability and low cytotoxicity to HeLa cells were also observed, suggesting its promising potential in bio-imaging.

Graphical Abstract

1. Introduction

Anions play an important role in a wide range of chemical and biological processes. Given this, anion recognition has been well studied in recent years [1]. Among various anions, cyanide anion (CN) is a well-known anion that is toxic to living organisms [2]. As advocated by the World Health Organization (WHO), the maximum concentration of cyanide anion in drinking water should be 1.9 µM [3]. However, CN is widely released from industry waste, certain natural plants, cigarette smoke, etc. [4], and can thus be a serious threat to people’s health and the environment. Hence, developing effective quantitative determination methods for CN is urgent and essential.
In order to quickly, easily and accurately detect cyanide anion, various analysis methods were developed, including titrimetric [5], electrochemical decices [6,7,8], voltammetric [9], fluorometric [10,11,12,13,14,15,16,17] and so on. Compared with other methods, fluorometric and colorimetric responses based on chemical reactions have attracted much attention due to their simple operation, high selectivity, high sensitivity and low cost [18,19,20,21,22]. The sensing mechanisms of fluorometric and colorimetric chemosenors for detecting CN have been reported over the past few years, including hydrogen bonding reactions [23,24,25,26,27], forming cyanide anion complexes [28,29], electron transfer reactions [30,31,32] and nucleophilic addition reactions [33,34,35,36,37,38,39,40]. Among them, the nucleophilic addition reactions generally have high selectivity for detecting CN.
Triphenylamine-based thiophene dicyanovinyl compounds, which contain an electron-donating triphenylamine moiety and a strong electron-withdrawing dicyanovinyl group, were reported as red-emitting fluorophores with large Stokes shifts [41]. In recent years, some fluorescent probes with dicyanovinyl moieties for detecting cyanide anions have been reported [42,43,44,45,46,47]. Consequently, we hypothesized that triphenylamine-based thiophene dicyanovinyl compounds could be applied to selectively detect cyanide anion.
With this hypothesis in mind, probe 1 was synthesized and exhibited prominent selectivity and sensitivity towards cyanide anion with significant turn-on fluorescent response in PBS/DMSO (4/6, v/v, pH = 7.4) solution (Scheme 1). Herein, we report a dual colorimetric and fluoresecent probe to selectively and sensitively detect cyanide anion in aqueous media. Moreover, low cytotoxicity and good cell membrane permeability in HeLa cells were also observed, suggesting its promising potential in bio-imaging.

2. Results and Discussion

2.1. Synthesis of Probe 1

As shown in Scheme 2, probe 1 was synthesized via a 3-step synthesis route according to a literature method [41]. The structure of probe 1 was fully characterized by NMR and ESI-MS spectroscopy. Detailed synthetic process and structure characterization are given in the Experimental section and in the Electronic Supplementary Information (ESI).

2.2. Selectivity over Other Anions

After the identification of the optimal fluorescence measurement conditions, a series of relevant and interfering anions were investigated to study the selectivity. Before the addition of various anions, the light-pink probe solution is non-fluorescent upon excited at 370 nm. The addition of 10 equivalents of 16 representative anions (S2−, HS, SO32−, S2O32−, S2O82−, I, Br, Cl, F, NO2, N3, SO42−, SCN, HCO3, CO32− and AcO) did not cause significant fluorescence changes (Figure 1a), whereas the color of the probe 1 solution faded in the presence of CN (10 equiv.) and the fluorescence intensity enhancement at 480 nm was remarkable. Based on the good selectivity of probe 1 toward CN, competition experiments were further explored. As shown in Figure 1b, the fluorescence intensity of probe + CN remained at a high level by the addition of other interfering anions (10 equiv.), suggesting that the response of probe 1 toward CN has good anti-interference ability.

2.3. Colorimetric and Fluorescent Detection

The UV-vis spectra changes of probe 1 (5 μM) upon addition of CN (50 μM) in PBS/DMSO (4/6, pH = 7.4) solution can be clearly observed (Figure S1) and the absorption at 505 nm decreased. The free probe 1 exhibits absorption at 505 nm with a pink color because of ICT process in the large π-conjugation. Subsequently, a colorimetric assay was performed. As shown in Figure 2a, among tested analytes, only cyanide anion resulted in an obvious color change from light pink to colourless. Moreover, a bright blue light was achieved in the solution of probe 1 with CN under the irradiation of a UV-lamp at 365 nm, which is visible by the naked eye (Figure 2b).

2.4. Spectral Titration of Probe 1

The fluorescence titration experiment was performed by adding different concentrations of cyanide anion ranging from 0 to 75 μM to a 5 μM solution of probe 1 (Figure S3). Saturation was observed when the concentration of cyanide anion was raised to 62.5 μM. As shown in Figure 3a, a concentration-dependent fluorescence enhancement was observed when CN from 0 to 25 μM was added at 480 nm. A good linear relationship between the fluorescence intensity and the concentration of CN could be obtained in the range of 0 to 25 μM (R2 = 0.99698).
To calculate the limit of detection (LOD), the standard deviation of the blank measurements was determined by measuring the fluorescent intensity of probe 1 10 times [48,49,50]. Based on the equation (LOD = 3σ/m) and the fluorescence titration, the LOD was calculated to be 51 nM, which is much lower than the maximum level of cyanide anion (1.9 µM) in drinking water permitted by the WHO, suggesting its promising potential for the detection of low levels of cyanide anion in water samples.

2.5. The Sensing Mechanism

As proposed in the literature [51], the sensing mechanism of probe 1 based on a nucleophilic addition reaction has been confirmed by 1H-NMR spectroscopy (Figure 4). Thus, to a 20 mM solution of probe 1 in CDCl3 cyanide anion (0.5 equiv.) was added at room temperature and a new proton signal appeared at 4.5 ppm (H2a). When the amount of CN was raised to 1.0 equiv., some significant proton signal changes were observed. For example, the vinyl proton signal (H1a, 7.73 ppm) disappeared gradually and a new proton signal at 4.5 ppm (H2a) was observed. The two proton signals on the thiophene ring (H1b, 7.66 ppm; H1c, 7.30 ppm) disappeared and were observed around 7.00 ppm. In addition, the two proton signals (H1d) adjacent to the thiophene ring shifted from 7.49 ppm to 7.36 ppm. These important proton signal changes conformed with the reference. While 1.5 equiv. CN was added, the reaction accomplished completely. In addition, the [1 − CN] adduct was characterized by mass spectrometry analysis, and the peak at m/z 457.1471 (calc. 457.1492) corresponding to [1 − CN] was clearly observed (Figure S10).

2.6. Cellular Imaging

To explore its potential in bio-imaging, the cytotoxicity of probe 1 was investigated by a standard MTT assay. As shown in Figure 5, HeLa cell viability was slightly reduced when the probe concentration was raised up to 40 µM, indicating acceptable cytotoxicity of probe 1.
Probe 1 was next applied to detect cyanide anion in living HeLa cells. As shown in Figure 6, HeLa cells were incubated with probe 1 (10 µM) for 1 h and then with different concentrations of CN (A, E: 0 µM; B, F: 10 µM; C, G: 80 µM; D, H: 160 µM) for 15 min. Under the fluorescent microscope, remarkable intracellular blue fluorescence was observed (Figure 6G–H). Moreover, the fluorescence intensity showed a concentration-dependent manner. As shown in Figure 7, HeLa cells were incubated with different concentrations of probe (0 µM; 2.5 µM; 5.0 µM; 10 µM) for 1 h and then with CN (80 µM) for 15 min. The fluorescence intensity also showed a concentration-dependent manner. In summary, probe 1 showed the potential to detect CN in vitro cellular systems in a concentration-dependent manner for both probe and CN.

3. Experimental Section

3.1. Materials and Instruments

All reagents were of analytical grade and used without further purification. The absorption and fluorescence spectra were measured on a UV-2450 (Shimadzu, Kyoto, Japan) instrument and a F-7000 (Hitachi, Tokyo, Japan) fluorescence spectrometer. 1H-NMR (300 MHz) and 13C-NMR (75 MHz) spectra were obtained on a Bruker-300 MHz spectrometer (Bruker, Fällanden, Switzerland) using tetramethylsilane (TMS) as an internal standard. The following abbreviations were used to denote the signal multiplicities: s for singlet, d for doublet, t for triplet, q for quartet, m for multiplet, br for broad. High-resolution mass spectra were obtained on a micrOTOF-Q mass spectrometer (Bruker, Bremen, Germany). Fluorescence cell imaging was performed with a fluorescence microscope (Olympus, Tokyo, Japan) with a 40× objective lens.

3.2. Synthesis of Probe 1

3.2.1. Synthesis of 4-bromo-N,N-di-p-tolylaniline (3)

4-Methyl-N-phenyl-N-(p-tolyl)aniline (1.00 g, 3.66 mmol) and NBS (0.68 g, 3.84 mmol) were dissolved in CHCl3 (20 mL). The mixture was stirred for 1.5 h at room temperature. The mixture was poured into water (50 mL) and then extracted with dichloromethane. The organic layer was washed with plenty of brine and dried over anhydrous sodium sulfate. The solvent was evaporated by a rotary evaporator. A white solid (1.28 g) was obtained. Yield: 99%.1H-NMR (CDCl3): δ 7.26 (d, J = 9.0 Hz, 1H), 7.06 (d, J = 8.2 Hz, 2H), 6.96 (d, J = 9.0 Hz, 2H), 6.87 (d, J = 6.0 Hz, 1H), 2.30 (s, 3H).

3.2.2. Synthesis of 5-(4-(di-p-tolylamino)phenyl)thiophene-2-carbaldehyde (4)

Dioxane (50 mL) was placed in a 3-necked round bottom flask and was purged with nitrogen for 30 min. Under a nitrogen atmosphere, compound 3 (1.00 g, 2.84 mmol), (5-formylthiophen-2-yl)boronic acid (1.35 g, 3.40 mmol), K2CO3 (2.00 g, 5.68 mmol) and Pd(PPh3)4 (164 mg, 0.14 mmol) were added. The mixture was violently refluxed for 3.5 h. After cooling to room temperature, the solvent was evaporated by a rotary evaporator. The residue was purified by column chromatography (silica gel, ethyl acetate/petroleum ether = 1:20) to give the compound 4. The product was obtained as a yellow solid (0.73 g). Yield: 67%. 1H-NMR (DMSO-d6): δ 9.84 (s, 1H), 7.93 (d, J = 4.0 Hz, 1H), 7.62 (d, J = 7.6 Hz, 2H), 7.56 (d, J = 4.0 Hz, 1H), 7.15 (d, J = 8.2 Hz, 4H), 6.98 (d, J = 8.3 Hz, 4H), 6.86 (d, J = 8.8 Hz, 2H), 2.27 (s, 6H); 13C-NMR (DMSO-d6): δ 183.6, 153.2, 148.9, 143.9, 140.6, 139.5, 133.5, 130.3, 127.3, 125.3, 124.5, 123.6, 120.3, 20.5.

3.2.3 Synthesis of 2-((5-(4-(di-p-tolylamino)phenyl)thiophen-2-yl)methylene)malononitrile (1)

To a solution of compound 4 (50 mg, 0.13 mmol) and malononitrile (13 mg, 0.19 mmol) dissolved in toluene (3 mL), and a drop of piperidine was added under a nitrogen atmosphere. The mixture was refluxed for 3 h. After cooling to room temperature, the solvent was evaporated by a rotary evaporator. The residue was purified by column chromatography (silica gel, ethyl acetate/petroleum ether = 1:10) to give the title compound 1 as a red solid (47 mg). Yield: 70%. 1H-NMR (CDCl3): δ 7.73 (s, 1H), 7.66 (d, J = 4.0 Hz, 1H), 7.49 (d, J = 8.8 Hz, 2H), 7.30 (d, J = 4.1 Hz, 1H), 7.13 (d, J = 8.2 Hz, 4H), 7.04 (d, J = 8.3 Hz, 4H), 6.98 (d, J = 8.7 Hz, 2H), 2.35 (s, 6H); 13C-NMR (CDCl3): δ 157.5, 150.3, 150.2, 143.9, 140.5, 134.2, 132.8, 130.2, 127.5, 125.6, 123.8, 122.9, 120.4, 114.6, 113.7, 74.5, 20.9; HRMS (ESI): m/z, [M + H]+ calcd. for C28H22N3S+, 432.1529; found, 432.1516.

3.3. General Fluorescence Spectra Measurements

Figure S4 shows that the fluorescence intensity of probe 1 (5 μM) was slightly affected within a range of pH (7.0–9.0) in the absence and presence of CN (50 μM) in PBS/DMSO (4/6) solution. The fluorescence responses of probe 1 were investigated in PBS/DMSO (4:6, v/v, pH = 7.4) solution. The response time of the probe 1 towards CN was 80 min (Figure S2). To ensure the reaction accomplish completely, fluorescence measurements were delayed for 1.5 h after anion addition.
Probe 1 was dissolved in DMSO to afford a concentration of 5 mM stock solution and then diluted to 5 μM with PBS/DMSO= 4/6 (v/v, pH = 7.4). Cyanide anion (10 mM) was offered by tetrabutylammonium cyanide. Moreover, miscellaneous interference anions (as their Na+ or K+ salt, 10 mM) including S2−, HS, SO32−, S2O32−, S2O82−, I, Br, Cl, F, NO2, N3, SO42−, SCN, HCO3, CO32− and AcO in deionized water were used for the sensing experiments. The fluorescence spectrum changes caused by CN (50 μM) and miscellaneous interference anions (50 μM) were recorded at room temperature using a fluorescence spectrometer (λex = 370 nm, λem = 480 nm, slits: 2.5 nm/5 nm).

3.4. Cell Culture and Confocal Fluorescence Imaging

HeLa cells were obtained from the State Key Laboratory of Biotherapy of Sichuan University. Cells were seeded to a 12-well plates, and were routinely maintained at 37 °C in a humidified 5% CO2 atmosphere using DMEM Growth medium with 10% fetal bovine serum for 24 h before use.
HeLa cells (Figure 6) were incubated with probe 1 (10 µM) for 1 h, and then washed with PBS five times. All cells were incubated with PBS for 15 min; finally with different concentrations of CN were added for 1 h at 37 °C: A, E with PBS; B, F with 10 µM CN; C, G with 80 µM CN; D, H with 160 µM CN. Then cells were washed with PBS five times. Fluorescence images were monitored at 425−520 nm for blue channels and the white light channel.
Next, HeLa cells (Figure 7) were incubated with different concentrations of probe 1 for 1 h: A, E with PBS; B, F with 2.5 µM probe 1); C, G with 5 µM probe 1; D, H with 10 µM probe 1. Then cells were washed with PBS five times. Then all cells were incubated with 80 µM CN for 15 min. Cell imaging was carried out after washing cells with PBS five times.

4. Conclusions

In summary, a colorimetric fluorescent probe 1 bearing triphenylamine-thiophene and dicyanovinyl groups has been synthesized. Probe 1 exhibited prominent selectivity and sensitivity for detecting cyanide anion with a significant turn-on fluorescent response in PBS/DMSO (4/6, v/v, pH = 7.4) solution. Moreover, a low detection limit (LOD, 51 nM) was achieved and it was noted that the probe 1 has potential for detecting level of cyanide anion in drinking water according to the requirements of the WHO (1.9 µM). In addition, good cell membrane permeability and low cytotoxicity to HeLa cells were also observed, suggesting its promising potential in bio-imaging.

Supplementary Materials

The following are available online at www.mdpi.com/1424-8220/17/2/405/s1: Additional spectral data for probe 1 and spectroscopic characterization of compounds 13.

Acknowledgments

This work was supported by the Basic Research Project of Sichuan Province (2014JY0205). We thank the Analytical and Testing Center of Sichuan University for fluorescent measurements.

Author Contributions

Li Yang and Qing-Fei Huang conceived and designed the experiments; Zi-Hua Zheng performed the synthetic and fluorescent experiments; Zhi-Ke Li and Lin-Jiang Song performed cell imaging; Qi-Wei Wang contributed reagents; Li Yang wrote the paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Busschaert, N.; Caltagirone, C.; Rossom, W.V.; Gale, P.A. Applications of supramolecular anion recognition. Chem. Rev. 2015, 115, 8038–8155. [Google Scholar] [CrossRef] [PubMed]
  2. Wang, F.; Wang, L.; Chen, X.; Yoon, J. Recent progress in the development of fluorometric and colorimetric chemosensors for detection of cyanide ions. Chem. Soc. Rev. 2014, 43, 4312–4324. [Google Scholar] [CrossRef] [PubMed]
  3. Merwe, S.W.; Schoeller, F.; Bolzer, W.; Germonper, R.; Heller, L.; Filho, E.H.; Formaggia, D.M.E.; Blum, J.C.; Omori, M.J.; Mancuso, P.C.S. Guidelines for Drinking-Water Quality; World Health Organization: Geneva, Switzerland, 1996. [Google Scholar]
  4. Kulig, K.W. Cyanide Toxicity; U.S. Department of Health and Human Services: Atlanta, GA, USA, 1991.
  5. Anzenbacher, P.J.; Tyson, D.S.; Jursikova, K.; Castellano, F.N. Luminescence lifetime-based sensor for cyanide and related anions. J. Am. Chem. Soc. 2002, 124, 6232–6233. [Google Scholar] [CrossRef] [PubMed]
  6. Ishii, A.; Seno, H.; Watanabe-Suzuki, K.; Suzuki, O. Determination of cyanide in whole blood by capillary gas chromatography with cryogenic oven trapping. Anal. Chem. 1998, 70, 4873–4876. [Google Scholar] [CrossRef] [PubMed]
  7. Timofeyenko, Y.G.; Rosentreter, J.J.; Mayo, S. Piezoelectric quartz crystal microbalance sensor for trace aqueous cyanide ion determination. Anal. Chem. 2007, 79, 251–255. [Google Scholar] [CrossRef] [PubMed]
  8. Ding, G.; Zhou, H.; Xu, J.; Lu, X. Electrofluorochromic detection of cyanide anions using a benzothiadiazole-containing conjugated copolymer. Chem. Commun. 2014, 50, 655–657. [Google Scholar] [CrossRef] [PubMed]
  9. Suzuki, T.; Hiolki, A.; Kurahashi, M. Development of a method for estimating an accurate equivalence point in nickel titration of cyanide ions. Anal. Chim. Acta 2003, 476, 159–165. [Google Scholar] [CrossRef]
  10. Cacace, D.; Ashbaugh, H.; Kouri, N.; Bledsoe, S.; Lancaster, S.; Chalk, S. Spectrophotometric determination of aqueous cyanide using a revised phenolphthalin method. Anal. Chim. Acta 2007, 589, 137–141. [Google Scholar] [CrossRef] [PubMed]
  11. Maldonado, C.R.; Touceda-Varela, A.; Jonesa, A.C.; Mareque-Rivas, J.C. A turn-on fluorescence sensor for cyanide from mechanochemical reactions between quantum dots and copper complexes. Chem. Commun. 2011, 47, 11700–11702. [Google Scholar] [CrossRef] [PubMed]
  12. Lee, K.S.; Kim, H.J.; Shin, I.; Hong, J.I. Fluorescent chemodosimeter for selective detection of cyanide in water. Org. Lett. 2008, 10, 49–51. [Google Scholar] [CrossRef] [PubMed]
  13. Badugu, R.; Lakowicz, J.R.; Geddes, C.D. Fluorescence intensity and lifetime-based cyanide sensitive probes for physiological safeguard. Anal. Chim. Acta 2004, 522, 9–17. [Google Scholar] [CrossRef]
  14. Badugu, R.; Lakowicz, J.R.; Geddes, C.D. Enhanced fluorescence cyanide detection at physiologically lethal levels: Reduced ICT-based signal transduction. J. Am. Chem. Soc. 2005, 127, 3635–3641. [Google Scholar] [CrossRef] [PubMed]
  15. Jung, H.S.; Han, J.H.; Kim, Z.H.; Kang, C.; Kim, J.S. Coumarin-Cu(II) ensemble-based cyanide sensing chemodosimeter. Org. Lett. 2011, 13, 5056–5059. [Google Scholar] [CrossRef] [PubMed]
  16. Lee, H.; Kim, H.J. Highly selective sensing of cyanide by a benzochromene-based ratiometric fluorescence probe. Tetrahedron Lett. 2012, 53, 5455–5457. [Google Scholar] [CrossRef]
  17. Park, S.; Kim, H.J. Highly activated Michael acceptor by an intramolecular hydrogen bond as a fluorescence turn-on probe for cyanide. Chem. Commun. 2010, 46, 9197–9199. [Google Scholar] [CrossRef] [PubMed]
  18. Xu, Z.; Chen, X.; Kim, H.N.; Yoon, J. Sensors for the optical detection of cyanide ion. Chem. Soc. Rev. 2010, 39, 127–137. [Google Scholar] [CrossRef] [PubMed]
  19. Kang, N.Y.; Ha, H.H.; Yun, S.W.; Yu, Y.H.; Chang, Y.T. Diversity-driven chemical probe development for biomolecules: Beyond hypothesis-driven approach. Chem. Soc. Rev. 2011, 40, 3613–3626. [Google Scholar] [CrossRef] [PubMed]
  20. Zou, Q.; Zou, L.; Tian, H. Detection and adsorption of Hg2+ by new mesoporous silica and membrane material grafted with a chemodosimeter. J. Mater. Chem. 2011, 21, 14441–14447. [Google Scholar] [CrossRef]
  21. Zou, Q.; Tian, H. Chemodosimeters for mercury(II) and methylmercury(I) based on 2,1,3-benzothiadiazole. Sens. Actuators B 2010, 149, 20–27. [Google Scholar] [CrossRef]
  22. Ren, J.Q.; Zhu, W.H.; Tian, H. A highly sensitive and selective chemosensor for cyanide. Talanta 2008, 75, 760–764. [Google Scholar] [CrossRef] [PubMed]
  23. Gong, W.T.; Zhang, Q.L.; Shang, L.; Gao, B.; Ning, G.L. A new principle for selective sensing cyanide anions based on 2-hydroxy-naphthaldeazine compound. Sens. Actuators B 2013, 177, 322–326. [Google Scholar] [CrossRef]
  24. Jo, J.; Lee, D. Turn-on fluorescence detection of cyanide in water: Activation of latent fluorophores through remote hydrogen bonds that mimic peptide β-turn motif. J. Am. Chem. Soc. 2009, 131, 16283–16291. [Google Scholar] [CrossRef] [PubMed]
  25. Gimeno, N.; Li, X.; Durrant, J.R.; Vilar, R. Cyanide sensing with organic dyes: Studies in solution and on nanostructured Al2O3 surfaces. Chem. Eur. J. 2008, 14, 3006–3012. [Google Scholar] [CrossRef] [PubMed]
  26. Chen, X.; Nam, S.; Kim, G.; Song, N.; Jeong, Y.; Shin, I.; Kim, S.K.; Kim, J.; Park, S.; Yoon, J. Cyanide sensing with organic dyes: Studies in solution and on nanostructured Al2O3 surfaces. Chem. Commun. 2010, 46, 8953–8955. [Google Scholar] [CrossRef] [PubMed]
  27. Dai, Z.; Boon, E.M. Engineering of the heme pocket of an H-NOX domain for direct cyanide detection and quantification. J. Am. Chem. Soc. 2010, 132, 11496–11503. [Google Scholar] [CrossRef] [PubMed]
  28. Lee, J.H.; Jeong, A.R.; Shin, I.S.; Kim, H.J.; Hong, J.I. Fluorescence turn-on sensor for cyanide based on a cobalt(II)-coumarinylsalen complex. Org. Lett. 2010, 12, 764–767. [Google Scholar] [CrossRef] [PubMed]
  29. Liu, Y.L.; Lv, X.; Zhao, Y.; Liu, J.; Sun, Y.Q.; Wang, P.; Guo, W. A Cu(II)-based chemosensing ensemble bearing rhodamine B fluorophore for fluorescence turn-on detection of cyanide. J. Mater. Chem. 2012, 22, 1747–1750. [Google Scholar] [CrossRef]
  30. Ajayakumar, M.R.; Mukhopadhyay, P. Single-electron transfer driven cyanide sensing: A new multimodal approach. Org. Lett. 2010, 12, 2646–2649. [Google Scholar] [CrossRef] [PubMed]
  31. Ajayakumar, M.R.; Asthana, D.; Mukhopadhyay, P. Core-modified naphthalenediimides generate persistent radical anion and cation: New panchromatic NIR probes. Org. Lett. 2012, 14, 4822–4825. [Google Scholar] [CrossRef] [PubMed]
  32. Ajayakumar, M.R.; Mandal, K.; Rawat, K.; Asthana, D.; Pandey, R.; Sharma, A.; Yadav, S.; Ghosh, S.; Mukhopadhyay, P. Single electron transfer-driven multi-dimensional signal read-out function of TCNQ as an “Off-the-Shelf” detector for cyanide. ACS Appl. Mater. Interfaces 2013, 5, 6996–7000. [Google Scholar] [CrossRef] [PubMed]
  33. Huo, F.J.; Su, J.; Sun, Y.Q.; Yin, C.X.; Chao, J.B. A new ring-opening chromene molecule: Colorimetric detection of cyanide anion. Chem. Lett. 2010, 39, 738–740. [Google Scholar] [CrossRef]
  34. Peng, M.J.; Guo, Y.; Yang, X.F.; Wang, L.Y.; An, J. A highly selective ratiometric and colorimetric chemosensor for cyanide detection. Dyes Pigment. 2013, 98, 327–332. [Google Scholar] [CrossRef]
  35. Shan, Y.; Liu, Z.; Cao, D.; Sun, Y.; Wang, K.; Chen, H. Nitro substituted chalcone derivatives as quick-response chemosensors for cyanide anions. Sens. Actuators B Chem. 2014, 198, 15–19. [Google Scholar] [CrossRef]
  36. Sun, X.; Wang, Y.; Deng, X.; Zhang, J.; Zhang, Z. A colorimetric and ratiometric fluorescent probe for the selective detection of cyanide anions in aqueous media and living cells. RSC. Adv. 2016, 6, 10266–10271. [Google Scholar] [CrossRef]
  37. Lv, X.; Liu, J.; Liu, Y.L.; Zhao, Y.; Chen, M.L.; Wang, P.; Guo, W. Rhodafluor-based chromo-and fluorogenic probe for cyanide anion. Sens. Actuators B Chem. 2011, 158, 405–410. [Google Scholar] [CrossRef]
  38. Jeong, Y.H.; Lee, C.H.; Jang, W.D. A Diketopyrrolopyrrole-Based Colorimetric and Fluorescent Probe for Cyanide Detection. Chem. Asian J. 2012, 7, 1562–1566. [Google Scholar] [CrossRef] [PubMed]
  39. Yuan, L.; Lin, W.Y.; Yang, Y.T.; Song, J.Z.; Wang, J.L. Rational design of a highly reactive ratiometric fluorescent probe for cyanide. Org. Lett. 2011, 13, 3730–3733. [Google Scholar] [CrossRef] [PubMed]
  40. Kim, H.J.; Ko, K.C.; Lee, J.H.; Lee, J.Y.; Kim, J.S. KCN sensor: Unique chromogenic and “turn-on” fluorescent chemodosimeter: Rapid response and high selectivity. Chem. Commun. 2011, 47, 2886–2888. [Google Scholar] [CrossRef] [PubMed]
  41. Li, Y.; Ren, T.; Dong, W.J. Tuning photophysical properties of triphenylamine and aromatic cyano conjugate-based wavelength-shifting compounds by manipulating intramolecular charge transfer strength. J. Photochem. Photobiol. A Chem. 2013, 251, 1–9. [Google Scholar] [CrossRef]
  42. Cheng, X.; Zhou, Y.; Qin, J.; Li, Z. Reaction-based colorimetric cyanide chemosensors: Rapid naked-eye detection and high selectivity. ACS Appl. Mater. Interfaces 2012, 4, 2133–2138. [Google Scholar] [CrossRef] [PubMed]
  43. Lee, C.H.; Yoon, H.J.; Shim, J.S.; Jang, W.D. A Boradiazaindacene-based turn-on fluorescent probe for cyanide detection in aqueous media. Chem. Eur. J. 2012, 18, 4513–4516. [Google Scholar] [CrossRef] [PubMed]
  44. Yang, L.; Li, X.; Yang, J.; Qu, Y.; Hua, J. Colorimetric and ratiometric near-infrared fluorescent cyanide chemodosimeter based on phenazine derivatives. ACS Appl. Mater. Interfaces 2013, 5, 1317–1326. [Google Scholar] [CrossRef] [PubMed]
  45. Zhang, Q.; Zhang, J.; Zuo, H.; Wang, C.; Shen, Y. A novel colorimetric and fluorescent sensor for cyanide anions detection based on triphenylamine and benzothiadiazole. Tetrahedron 2016, 72, 1244–1248. [Google Scholar] [CrossRef]
  46. Qu, Y.; Jin, B.; Liu, Y.; Wu, Y.; Yang, L.; Wu, J.; Hua, J. A new triphenylamine fluorescent dye for sensing of cyanide anion in living cell. Tetrahedron Lett. 2013, 54, 4942–4944. [Google Scholar] [CrossRef]
  47. Zou, Q.; Li, X.; Xu, Q.; Ågren, H.; Zhao, W.; Qu, Y. A near-infrared “on-off” fluorescent and colourimetric cyanide chemodosimeter based on phenothiazine with applications in living cell imaging. RSC Adv. 2014, 4, 59809–59816. [Google Scholar] [CrossRef]
  48. Wang, S.; Xu, H.; Yang, Q.; Song, Y.; Li, Y. A triphenylamine-based colorimetric and “turn-on” fluorescent probe for detection of cyanide anions in live cells. RSC Adv. 2015, 5, 47990–47996. [Google Scholar] [CrossRef]
  49. Yang, Y.; Yin, C.; Huo, F.; Chao, J.; Zhang, Y.; Cheng, F. A new highly selective and turn-on fluorescence probe for detection of cyanide. Sens. Actuators B Chem. 2014, 193, 220–224. [Google Scholar] [CrossRef]
  50. Sun, Y.; Fan, S.; Duan, L.; Li, R. A ratiometric fluorescent probe based on benzo [e] indolium for cyanide ion in water. Sens. Actuators B Chem. 2013, 185, 638–643. [Google Scholar] [CrossRef]
  51. Pati, P.B.; Zade, S.S. Dicyanovinyl terthiophene as a reaction based colorimetric and ratiometric fluorescence probe for cyanide anions. RSC Adv. 2013, 3, 13457–13462. [Google Scholar] [CrossRef]
Scheme 1. The sensing mechanism of probe 1.
Scheme 1. The sensing mechanism of probe 1.
Sensors 17 00405 sch001
Scheme 2. The synthesis of probe 1; Reagents and Conditions: (a) NBS, DMF, r.t., 99% yield; (b) (5-formylthiophen-2-yl) boronic acid, Pd(PPh3)4, dioxane, reflux, 3.5 h, 67% yield; (c) malononitrile, piperidine, reflux, 3 h, 70% yield.
Scheme 2. The synthesis of probe 1; Reagents and Conditions: (a) NBS, DMF, r.t., 99% yield; (b) (5-formylthiophen-2-yl) boronic acid, Pd(PPh3)4, dioxane, reflux, 3.5 h, 67% yield; (c) malononitrile, piperidine, reflux, 3 h, 70% yield.
Sensors 17 00405 sch002
Figure 1. (a) Fluorescent responses of probe 1 (5 μM) towards various anions (50 μM) in PBS/DMSO (4/6, pH = 7.4) solution. λex = 370 nm, Slits: 2.5 nm/5 nm; (b) Competing responses of probe 1 (5 μM) at 480 nm towards various analytes (50 μM) in PBS/DMSO (4/6, pH = 7.4) solution. Black bar, probe and probe + anions; red bar, probe + CN + anions. λex = 370 nm, Slits: 2.5 nm/5 nm.
Figure 1. (a) Fluorescent responses of probe 1 (5 μM) towards various anions (50 μM) in PBS/DMSO (4/6, pH = 7.4) solution. λex = 370 nm, Slits: 2.5 nm/5 nm; (b) Competing responses of probe 1 (5 μM) at 480 nm towards various analytes (50 μM) in PBS/DMSO (4/6, pH = 7.4) solution. Black bar, probe and probe + anions; red bar, probe + CN + anions. λex = 370 nm, Slits: 2.5 nm/5 nm.
Sensors 17 00405 g001
Figure 2. Fluorescence images of probe 1 (5 μM) upon addition of various anions (50 μM) in PBS/DMSO (4/6, pH = 7.4) solution under visible light (a); and 365 nm UV lamp (b).
Figure 2. Fluorescence images of probe 1 (5 μM) upon addition of various anions (50 μM) in PBS/DMSO (4/6, pH = 7.4) solution under visible light (a); and 365 nm UV lamp (b).
Sensors 17 00405 g002
Figure 3. (a) Fluorescence spectra of probe 1 (5 μM) in the presence of various concentration of CN (0–25 μM) in PBS/DMSO (4/6, pH = 7.4) solution; (b) Linear relation between the fluorescent intensity at 480 nm and the concentration of CN in the range of 0–25 μM. λex = 370 nm, Slits: 2.5 nm/5 nm.
Figure 3. (a) Fluorescence spectra of probe 1 (5 μM) in the presence of various concentration of CN (0–25 μM) in PBS/DMSO (4/6, pH = 7.4) solution; (b) Linear relation between the fluorescent intensity at 480 nm and the concentration of CN in the range of 0–25 μM. λex = 370 nm, Slits: 2.5 nm/5 nm.
Sensors 17 00405 g003
Figure 4. 1H-NMR spectral changes of probe 1 (20 mM) upon addition of CN (as tetrabutylammonium salts) in CDCl3.
Figure 4. 1H-NMR spectral changes of probe 1 (20 mM) upon addition of CN (as tetrabutylammonium salts) in CDCl3.
Sensors 17 00405 g004
Figure 5. HeLa cell viability values (%) estimated by MTT assay at different concentrations of probe 1 for 24 h.
Figure 5. HeLa cell viability values (%) estimated by MTT assay at different concentrations of probe 1 for 24 h.
Sensors 17 00405 g005
Figure 6. Images of living HeLa cells: HeLa cells incubated with probe 1 (10 μM) for 1 h and then with different concentration of CN ((A,E) 0 μM; (B,F) 10 μM; (C,G) 80 μM; (D,H) 160 μM) for 15 min. (AD) is Bright field; (EH) is under fluorescence (λex = 385 nm, λem = 405–440 nm) blue channel (425 nm–520 nm), scale bar: 20 μm.
Figure 6. Images of living HeLa cells: HeLa cells incubated with probe 1 (10 μM) for 1 h and then with different concentration of CN ((A,E) 0 μM; (B,F) 10 μM; (C,G) 80 μM; (D,H) 160 μM) for 15 min. (AD) is Bright field; (EH) is under fluorescence (λex = 385 nm, λem = 405–440 nm) blue channel (425 nm–520 nm), scale bar: 20 μm.
Sensors 17 00405 g006
Figure 7. Images of living HeLa cells: HeLa cells incubated with different concentration of probe 1 ((A,E) 0 μM; (B,F) 2.5 μM; (C,G) 5 μM; (D,H) 10 μM) for 1 h and then all cells were incubated with 80 µM CN for 15 min. (AD) is Bright field; (EH) is under fluorescence (λex = 385 nm, λem = 405–440 nm), scale bar: 20 μm.
Figure 7. Images of living HeLa cells: HeLa cells incubated with different concentration of probe 1 ((A,E) 0 μM; (B,F) 2.5 μM; (C,G) 5 μM; (D,H) 10 μM) for 1 h and then all cells were incubated with 80 µM CN for 15 min. (AD) is Bright field; (EH) is under fluorescence (λex = 385 nm, λem = 405–440 nm), scale bar: 20 μm.
Sensors 17 00405 g007

Share and Cite

MDPI and ACS Style

Zheng, Z.-H.; Li, Z.-K.; Song, L.-J.; Wang, Q.-W.; Huang, Q.-F.; Yang, L. A Biocompatible Colorimetric Triphenylamine- Dicyanovinyl Conjugated Fluorescent Probe for Selective and Sensitive Detection of Cyanide Ion in Aqueous Media and Living Cells. Sensors 2017, 17, 405. https://doi.org/10.3390/s17020405

AMA Style

Zheng Z-H, Li Z-K, Song L-J, Wang Q-W, Huang Q-F, Yang L. A Biocompatible Colorimetric Triphenylamine- Dicyanovinyl Conjugated Fluorescent Probe for Selective and Sensitive Detection of Cyanide Ion in Aqueous Media and Living Cells. Sensors. 2017; 17(2):405. https://doi.org/10.3390/s17020405

Chicago/Turabian Style

Zheng, Zi-Hua, Zhi-Ke Li, Lin-Jiang Song, Qi-Wei Wang, Qing-Fei Huang, and Li Yang. 2017. "A Biocompatible Colorimetric Triphenylamine- Dicyanovinyl Conjugated Fluorescent Probe for Selective and Sensitive Detection of Cyanide Ion in Aqueous Media and Living Cells" Sensors 17, no. 2: 405. https://doi.org/10.3390/s17020405

APA Style

Zheng, Z. -H., Li, Z. -K., Song, L. -J., Wang, Q. -W., Huang, Q. -F., & Yang, L. (2017). A Biocompatible Colorimetric Triphenylamine- Dicyanovinyl Conjugated Fluorescent Probe for Selective and Sensitive Detection of Cyanide Ion in Aqueous Media and Living Cells. Sensors, 17(2), 405. https://doi.org/10.3390/s17020405

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop