Response of a Zn2TiO4 Gas Sensor to Propanol at Room Temperature

1
Faculty of Engineering, Electrical & Electronics Eng. Department, Sirte University, Sirte, Libya
2
Advanced Processing Technology Research Centre, Dublin City University, Dublin 9, Ireland
*
Author to whom correspondence should be addressed.
Sensors 2017, 17(9), 1995; https://doi.org/10.3390/s17091995
Submission received: 29 June 2017 / Revised: 6 August 2017 / Accepted: 9 August 2017 / Published: 31 August 2017
(This article belongs to the Special Issue Materials and Applications for Sensors and Transducers)

Abstract

:
In this study, three different compositions of ZnO and TiO2 powders were cold compressed and then heated at 1250 °C for five hours. The samples were ground to powder form. The powders were mixed with 5 wt % of polyvinyl butyral (PVB) as binder and 1.5 wt % carbon black and ethylene-glyco-lmono-butyl-ether as a solvent to form screen-printed pastes. The prepared pastes were screen printed on the top of alumina substrates containing arrays of three copper electrodes. The three fabricated sensors were tested to detect propanol at room temperature at two different concentration ranges. The first concentration range was from 500 to 3000 ppm while the second concentration range was from 2500 to 5000 ppm, with testing taking place in steps of 500 ppm. The response of the sensors was found to increase monotonically in response to the increment in the propanol concentration. The surface morphology and chemical composition of the prepared samples were characterized by Scanning Electron Microscopy (SEM) and X-Ray Diffraction (XRD). The sensors displayed good sensitivity to propanol vapors at room temperature. Operation under room-temperature conditions make these sensors novel, as other metal oxide sensors operate only at high temperature.

1. Introduction

The detection and quantification of alcohols with high sensitivity and selectivity is required in various industrial sectors, such as the pharmaceutical, chemical, clinical laboratories, agro-food and alcohol-based fuel industries. A number of conventional spectroscopic techniques are currently used in industries for accurate alcohol detection. However, these techniques often require complex sample preparation steps, and therefore need highly skilled and trained operators, and are not suitable for rapid onsite measurements. Due to complexity of the instruments and the high costs, the requirement for highly sensitive and selective alcohol sensors with real-time monitoring capabilities has increased. Alcohol sensors can be categorized on the basis of the type of transducer used to convert the alcohol content information into an electrical signal. Chemical- and enzyme-based biosensors are two major classes of alcohol sensors. Biosensors are highly selective in nature, due to the specific reaction between the enzyme and the tested alcohol; they are not suitable for long-term use, and have limited shelf-life. Chemical sensors demonstrate high sensitivity, but are prone to poor selectivity. Semiconducting metal oxide composite materials have been used as the sensing element for fabrication of thin film chemical alcohol sensors. Thin film metal oxide sensors are inexpensive, easy to fabricate, demonstrate long term stability, and provide real-time monitoring. However, metal oxide sensors require high operating temperatures as the sensing material needs to be heated up to several hundred degrees to transform from insulator to semiconductor. For example, the sensitivity of SnO2- and In2O3-based sensors with platinum interdigitated electrodes on alumina substrates for detecting ethanol was investigated over a range of 10–5000 ppm [1]. A TiO2 thin film was used to detect alcohol by Sberveglieri et al. [2]. This sensor was fabricated on alumina substrate with Pt interdigitated electrodes using a sol-gel technique. The sensor was used to detect methanol, ethanol and propanol at 2100, 2000 and 2600 ppm at operating temperatures of 300, 400 and 500 °C, respectively. In another study, SrFeO3 oxide P-type semiconductor gas sensor was investigated. A solid-state reaction method was used to deposit the sensing material. The sensor worked at operating temperatures of 275 to 375 °C and a concentration range of 0–2000 ppm [3]. This sensor demonstrated good sensitivity and selectivity to the vapors of Ethanol (C2H5OH). The effect of adding CdO to ZnFe2O4-based semiconductors for improved sensitivity in air and for ethanol was reported [4]. A Zn2TiO4 ethanol gas sensor was investigated. The sensor was used at concentration ranges of 50 and 200 ppm at 300–500 °C [5]. TiO2 thin film-based gas sensors were demonstrated for detection of methanol, ethanol and benzene at room temperature [6]. Titanium and tungsten oxide-based gas sensors were used to detect NO2 and CO [7]. Nb-doped titanium dioxide thin films with a thickness of 300 nm, deposited on Al2O3 substrate, were used to detect nitrogen dioxide (NO2) [8]. The sensitivity of the sensor to NO2 was recorded to be 1.0/ppm at 350 °C. Improved sensitivity of ZnO nano-wires on hydrogen sulfide (H2S) was also demonstrated, emphasizing the effect of nano-size effect on producing high response in presence of even trace-level of a gas [9]. The sensor was used to detect different gases, and showed good sensitivity and selectivity to H2S at low concentrations (5 ppb). The sensor was tested at an operating temperature of 300 °C. A micro hotplate was used to control the temperature. TiO2 thin film for detecting NO2 was investigated [10]. A ZnO sensor was used to detect O3 (0.1 ppm) [11]. The sensor exhibited the highest sensitivity to O3 at 250 °C. A gas sensor based on Zn2TiO4 as a sensing material for ethanol was studied [5]. The sensor was tested at operating temperatures of 300–500 °C, and exhibited the highest sensitivity at 500 °C. TiO2 and ZnO, or mixture of both, have been used by many researchers to detect different gases. For example, TiO2/ZnO has been used to detect ethanol [12,13], ZnO to detect NO2 [14], and TiO2 to detect chloroform [15].
Some mixture formulas, such as xCO2O4, xFe2O4 and xTiO4 (x = Ni, Cu, Zn, Zn2, Sn, Cd, Mg, etc.), have become more common to use in gas sensing applications. xCo2O4 (x = Ni, Cu, or Zn) was used to detect CH3COOH at 300 °C [16]. ZnCo2O4 and Zn2SnO4/SnO2 gas sensors were investigated to detect CO, C3H8 and NO2 at 600 °C [17]. A ZnCo2O4 sensor exhibited a good sensitivity to LPG at both high and low temperatures. The sensor was tested at (room temperature −400 °C). The highest sensitivity to 40 ppm LPG was recorded at 250 °C [18]. A NiCo2O4 sensor was studied for detecting O3 [19]; the sensor demonstrated the highest sensitivity at 200 °C. Table 1 presents a brief list of selective research studies on different metal oxide composite sensing materials developed to test selected gases.
It can be concluded from the research studies that a high operating temperature is required for transforming the metal oxides from insulator to semiconductor state. Hotplates are normally used to increase the temperature of the sensing material for sensing the desired gas. This results in high power consumption, oxidation of sensing materials, and limited use of the sensing materials for miniaturized sensing platforms and wearable sensors. Additionally, gold or platinum electrodes are commonly used, which makes these sensors expensive.
These limitations of metal oxide-based sensors have encouraged researchers to use polymer gas sensors, which work at room temperature with low power consumption. For example, to detect methanol, ethanol and benzene at room temperature, a TiO2 dispersed in poly vinylidenflouoride (PVDF) gas sensor was used [6]. The film was deposited on glass substrate with gold electrodes. The sensor not only demonstrated a great sensitivity to methanol, ethanol and benzene gases at low concentrations, but longer response (2 min) and recovery (6 min) times were also recorded. Although the shelf-life of conductive polymer-based metal oxide gas sensors is limited compared to the above-mentioned sensors, they still have a longer lifetime than enzyme-based biosensors [20]. In previous studies by our group, NiFe2O4 and ZnFe2O4 gas sensors were developed and tested for sensing methanol, ethanol, and propanol at room temperature [21,22,23].
In the current study, new composite materials were developed by mixing different weight percentages of TiO2 and ZnO to fabricate a novel gas sensor with high sensitivity towards alcohols. The conductive polymer polyvinyl butyral (PVB) was mixed with the metal oxide composites, along with carbon black, to increase the porosity and make them operational at room temperature. The morphological and chemical characterizations of the prepared samples were examined, and the developed sensors were tested for sensing propanol vapors using a specially designed gas test chamber. The response of the developed sensors was recorded for propanol vapors at two concentration ranges (500 to 3000 ppm and 2500 to 5000 ppm) at room temperature.

2. Experimental Work

Titanium dioxide (TiO2), zinc oxide (ZnO) and carbon black was supplied by Alfa Aesar. Figure 1 shows the experimental working steps. Three powder samples with different molecular weight percentage of TiO2 and ZnO were prepared according to Table 2. Samples were prepared using 75, 50 and 25 Mwt % of TiO2, mixed with 25, 50 and 75 Mwt % of ZnO. The powders were mixed with wet-ball milled in alcohol for 24 h, dried in an oven at 120 °C, and then compressed at 2 ton to form pallets. The pallets were heated in a furnace at 1250 °C at a rate of 5 °C/min, followed by a cooling rate of 3 °C/min in air. The solid pallets were then broken up and ground down to powder form using mortar and pestle. The powders were filtered with a 10 micron sieve. The powders were mixed again with a wet-ball mill in alcohol (isopropanol) and then dried again in an oven to produce fine powders.
Two grams of prepared powder from each sample was mixed with 5 wt % of polyvinyl butyral (PVB) and 1.5 wt % carbon black. PVB was used as a binder and carbon black was used to increase the conductivity of the films. Ethylen-glycol-monobutyl-ether was used as a solvent for PVB to make pastes for screen printing. To fabricate sensors, alumina substrates were used to deposit copper electrodes using a novel approach as described previously [48]. The prepared pastes were then screen printed on the top of thin copper electrodes on alumina substrate using a DEK RS 1202 automatic screen printer. Figure 2 presents the configuration of the developed sensors. SEM images were obtained for the mixed powders and screen-printed thin films. XRD measurements (from 10° to 70°, 2θ) were also performed on the screen-printed sensing materials to examine the final compositions.
A gas testing chamber, designed and developed previously, was used to test the response of the three screen-printed sensors with different molecular weights of metal oxides. This specially designed gas testing chamber enable measurement of different gases with predefined concentrations using screen-printed sensors.

3. Results and Discussion

3.1. SEM and XRD Results

Figure 3A,C,E shows the SEM images for the powders of sample 1, 75/25; sample 2, 50/50; and sample 3, 25/75 TiO2/ZnO Mwt% and Figure 3B,D,F shows the corresponding screen-printed thin films. The SEM images of powders from all three samples demonstrated similar morphology. The powder grain size was typically between 2 and 5 microns. The SEM images of the screen-printed films (Figure 3B,D,E) demonstrated uniform deposition of the sensing material. The samples displayed a granular structure and good porosity. For Sample 1, with the highest TiO2 contents, a large granular and porous structure was observed. For Sample 2, the screen-printed film showed a similar structure to sample one. The grain size was smaller than that of the Sample 1 sensor; however, the porosity was similar. In the third sample, a fine granulated structure was observed with an average grain size of 1 micron to 5 microns.
Figure 4 shows the XRD patterns of screen-printed samples from 10° to 70°, 2θ. The results were analyzed using JCPDs files No.: 18-1487 and 01-1292 for Zn2TiO4 and TiO2, respectively. XRD data of the samples showed that, after heating and screen printing, the ratio of Zn2TiO4 to TiO2 depended mainly on the ratio of TiO2 to ZnO used in the preparation of the powder mixtures before heating. XRD data for Sample 2 and Sample 3, with 50/50 and 25/75 Mwt % of TiO2/ZnO, showed that the highest intensity was observed for the peak associated with Zn2TiO4. However, in the case of Sample 1 (with 75/25 Mwt % TiO2/ZnO), the highest intensity in the final composition was observed for TiO2. The differences observed in the final compositions were due to solid-state reactions between both oxides during heating, and the ratio of oxides in the mixtures. Therefore, many characteristic peaks of TiO2 were observed in the final composition of Sample 1. The XRD results of Zn2TiO4 were in good agreement with the previous studies [5,49,50,51].

3.2. Response of the Sensors to Propanol

Figure 5 shows the response of the sensors to propanol vapors at room temperature in increasing steps of 500 ppm at a concentration range of 500–3000 ppm. Figure 6A,B illustrates the response of the sensors to propanol vapors at room temperature at a concentration range of 2500–5000 ppm. The response for the sensors was calculated using the following relationship:
Δ R = ( R g a s R a i r R a i r ) × 100
where ΔR is change in resistance, Rgas is sensor resistance when exposed to gas, and Rair is base resistance of the sensor in air.
From these results, it can be concluded that:
  • The response of the sensors increased as the gas concentration increased;
  • However, no significant difference was observed in the response of the three sensors at low concentrations; sensor 2 (50/50 TiO2/ZnO) had the highest sensitivity for propanol, followed by sensor 3 and then sensor 1 at higher concentrations (above 4000 ppm);
  • This difference in sensor response could be associated with the final composition of the sensing materials. The XRD results proved that the peaks of Zn2TiO4 were higher for Samples 2 and 3 (the highest density) than for Sample 1. The TiO2 was at the highest density in Sample 1. In addition to this, the surface morphology of the three samples was also different in terms of the number, size and shape of the pores on the surface of the films (see Figure 3);
  • The signal noise was high in the lower concentration range (500–2500 ppm) compared with the response of the same sensors for the higher concentration range (2500–5000 ppm). This high noise could be attributed to the effect of a slight change in the working temperature or the effect of some other gases that were already in the air of the gas testing chamber.
In a previous study, Zn2TiO4 particles were prepared using the ball-milling technique, and deposited as a thick film to detect alcohol gases (ethanol) at 50 and 200 ppm over an operating temperature range of 300–500 °C [5]. The highest sensitivity of the sensor was observed at 500 °C. The sensor was developed without using any polymer binder, and can only be used for high temperature applications. ZnFe2O4 and NiFe2O4 thick films were also used in previous studies by our group to detect methanol, ethanol and propanol at room temperature [21,22,23,52]. In the current study, Zn2TiO4 exhibited good sensitivity to propanol at room temperature. The response of the sensor depends on the final composition of the sensing material. In this study, no significant effect was observed in the final composition of the response, particularly at lower concentrations, as can be seen in Figure 5 and Figure 6.
It is well known that the interaction of a gas on the sensing material surface depends on the type of the sensing material (p- or n-type) and type of testing gas (oxidation or reduction gases). These two factors provide the basis for the increment or decrement in the resistivity of films.
The reaction of the gas on the surface of metal oxides has been reported in many studies [5,11,13,15,24]. However, the mechanism of the reaction of the gases on the surface of the films is still not well understood. In particular, for the sensors developed and tested in the current study, the interaction mechanism and conductivity response would be influenced by the complicated chemistry of the sensing material, which consists of composite metal oxides, polymer, and carbon black. Further detailed studies will be performed to investigate the adsorption of gas molecules on to the sensing material surface.
The Zn2TiO4 sensors developed in this study were novel in terms of composition. Conductive polymer was used as binder to combine the oxides and adhere it to the substrate. This study indicates that the use of the conductive polymer increased the pores in the surface of the films, which increased the sensitivity of the sensors at room temperature without heating the sensing material. Therefore, these sensors can be used for real-time monitoring of propanol with lower power consumption requirements; thus, they can be used in miniaturized sensing platforms and wearable sensing systems. Additionally, the use of copper electrodes makes the sensor more cost effective and able to interface with electronic circuits in simple configurations.

4. Conclusions

In the current work, the composition of ZnO/TiO2 was varied significantly from those reported in the literature and, as a result, properties were observed that were different from those previously reported. Thick film gas sensors, based on a Zn2TiO4 semiconductor with different ZnO and Ti2O contents were developed and tested for sensing propanol vapors. The electrochemical results from these sensors showed:
  • They had good sensitivity to propanol vapor at room temperature;
  • The response of the sensors monotonically increased as the gas concentration increased;
  • XRD measurements of the screen-printed sensing materials illustrated that the final compositions (Zn2TiO4 to TiO2) depended on the ratio of TiO2 to ZnO used in preparing the mixtures before being heated;
  • SEM images of the films showed granular microstructure ranging from 2–5 microns;
  • Using copper as an electrode material makes sensors cost effective compared to sensors with Pt and Au electrodes;
  • The developed sensors consume very low power compared with those sensors reported in the literature in [5,12], as heating of the sensing material is not required;
  • The simple structure of the sensor with copper electrodes makes it easy to interface with electrical systems;
  • The developed sensors can be used in various applications at room temperature, including as gas safety monitors;
  • Further detailed studies are required to better understand the interaction mechanism between the sensing material and the tested gas.

Acknowledgments

This publication has emanated from research conducted with the financial support of the European Union’s Horizon 2020 Research and Innovation Programme under grant agreement No. 691473.

Author Contributions

All authors contributed in conceiving and designing the experiments. Ibrahim Gaidan performed the experiments. All authors analyzed the data and contributed in writing the paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Takada, T. Temperature drop of semiconductor gas sensor when exposed to reducing gases—Simultaneous measurement of changes in sensor temperature and in resistance. Sens. Actuators B Chem. 2000, 66, 1–3. [Google Scholar] [CrossRef]
  2. Sberveglieri, G.; Comini, E.; Faglia, G.; Atashbar, M.Z.; Wlodarski, W. Titanium dioxide thin films prepared for alcohol microsensor application. Sens. Actuators B Chem. 2000, 66, 139–141. [Google Scholar] [CrossRef]
  3. Wang, Y.; Chen, J.; Wu, X. Preparation and gas-sensing properties of perovskite-type SrFeO3 oxide. Mater. Lett. 2001, 49, 361–364. [Google Scholar] [CrossRef]
  4. Chu, X.; Liu, X.; Meng, G. Effects of CdO dopant on the gas sensitivity properties of ZnFe2O4 semiconductors. Sens. Actuators B Chem. 2000, 65, 1–3. [Google Scholar]
  5. Santhaveesuk, T.; Gardchareon, A.; Wongratanaphisan, D.; Choopun, S. Ethanol sensing properties of Zn2TiO4 particles. Ceram. Int. 2015, 41, S809–S813. [Google Scholar] [CrossRef]
  6. Mabrook, M.; Hawkins, P. A rapidly-responding sensor for benzene, methanol and ethanol vapours based on films of titanium dioxide dispersed in a polymer operating at room temperature. Sens. Actuators B Chem. 2001, 75, 197–202. [Google Scholar] [CrossRef]
  7. Carotta, M.C.; Ferroni, M.; Gnani, D.; Guidi, V.; Merli, M.; Martinelli, G.; Casale, M.C.; Notaro, M. Nanostructured pure and Nb-doped TiO2 as thick film gas sensors for environmental monitoring. Sens. Actuators B Chem. 1999, 58, 310–317. [Google Scholar] [CrossRef]
  8. Yamada, Y.; Seno, Y.; Masuoka, Y.; Nakamura, T.; Yamashita, K. NO2 sensing characteristics of Nb doped TiO2 thin films and their electronic properties. Sens. Actuators B Chem. 2000, 66, 164–166. [Google Scholar] [CrossRef]
  9. Chen, Y.; Xu, P.; Xu, T.; Zheng, D.; Li, X. ZnO-nanowire size effect induced ultra-high sensing response to ppb-level H2S. Sens. Actuators B Chem. 2017, 240, 264–272. [Google Scholar] [CrossRef]
  10. Xie, T.S.; Steffens, N.; Wen, K.; Liu, B.; Debnath, G.; Davydov, R.; Gomez, A.; Motayed, A. UV-assisted room-temperature chemiresistive NO2 sensor based on TiO2 thin film. J. Alloys Compd. 2015, 653, 255–259. [Google Scholar] [CrossRef] [PubMed]
  11. Catto, A.C.; da Silva, L.F.; Ribeiro, C.; Bernardini, S.; Aguir, K.; Longo, E.; Mastelaro, V.R. An easy method of preparing ozone gas sensors based on ZnO nanorods. RSC Adv. 2015, 5, 19528–19533. [Google Scholar] [CrossRef]
  12. Santhaveesuk, T.; Wongratanaphisan, D.; Choopun, S. Enhancement of Ethanol Sensing Properties by Alloying. IEEE Sens. J. 2010, 10, 39–43. [Google Scholar] [CrossRef]
  13. Chen, H.; Liu, Y.; Xie, C.; Wu, J.; Zeng, D.; Liao, Y. A comparative study on UV light activated porous TiO2 and ZnO film sensors for gas sensing at room temperature. Ceram. Int. 2012, 38, 503–509. [Google Scholar] [CrossRef]
  14. Mun, Y.; Park, S.; An, S.; Lee, C.; Kim, H.W. NO2 gas sensing properties of Au-functionalized porous ZnO nanosheets enhanced by UV irradiation. Ceram. Int. 2013, 39, 8615–8622. [Google Scholar] [CrossRef]
  15. Perillo, P.M.; Rodrígue, D.F. A room temperature chloroform sensor using TiO2 nanotubes. Sens. Actuators B Chem. 2014, 193, 263–266. [Google Scholar] [CrossRef]
  16. Zhang, G.-Y.; Guo, B.; Chen, J. MCo2O4 (M = Ni, Cu, Zn) nanotubes: Template synthesis and application in gas sensors. Sens. Actuators B Chem. 2006, 114, 402–409. [Google Scholar] [CrossRef]
  17. Sun, F.; Li, X.; Liu, L.; Wang, J. Novel Zn–M–O (M = Sn, Co) sensing electrodes for selective mixed potential CO/C3H8 sensors. Sens. Actuators B Chem. 2013, 184, 220–227. [Google Scholar] [CrossRef]
  18. Gawande, K.B.; Gawande, S.B.; Thakare, S.R.; Mate, V.R.; Kadam, S.R.; Kale, B.B.; Kulkarni, M.V. Effect of zinc: Cobalt composition in ZnCo2O4 spinels for highly selective liquefied petroleum gas sensing at low and high temperatures. RSC Adv. 2015, 5, 40429–40436. [Google Scholar] [CrossRef]
  19. Joshi, N.; da Silva, L.F.; Jadhav, H.; M’Peko, J.C.; Torres, B.B.M.; Aguir, K.; Mastelaroa, V.R.; Oliveira, O.N., Jr. One-step approach for preparing ozone gas sensors based on hierarchical NiCo2O4 structures. RSC Adv. 2016, 6, 92655–92662. [Google Scholar] [CrossRef]
  20. Schaller, E.; Bosset, J.O.; Escher, F. ‘Electronic noses’ and their application to food. LWT-Food Sci. Technol. 1998, 31, 305–316. [Google Scholar] [CrossRef]
  21. Arshak, K.; Gaidan, I.; Moore, E.G.; Cunniffe, C. The effect of the addition of carbon black and the increase in film thickness on the sensing layers of ZnO/ZnFe2O4 in polymer thick film gas sensors. Superlattices Microstruct. 2007, 42, 348–356. [Google Scholar] [CrossRef]
  22. Arshak, K.; Gaidan, I. NiO/Fe2O3 polymer thick films as room temperature gas sensors. Thin Solid Films 2006, 495, 286–291. [Google Scholar] [CrossRef]
  23. Arshak, K.; Gaidan, I. Effects of NiO/TiO2 addition in ZnFe2O4-based gas sensors in the form of polymer thick films. Thin Solid Films 2006, 495, 292–298. [Google Scholar] [CrossRef]
  24. Da Silva, L.F.; M’Peko, J.C.; Catto, A.C.; Bernardini, S.; Mastelaro, V.R.; Aguir, K.; Ribeiro, C.; Longo, E. UV-enhanced ozone gas sensing response of ZnO-SnO2 heterojunctions at room temperature. Sens. Actuators B Chem. 2017, 240, 573–579. [Google Scholar] [CrossRef]
  25. Hongsith, N.; Choopun, S. Enhancement of ethanol sensing properties by impregnating platinum on surface of zno tetrapods. IEEE Sensors J. 2010, 10, 34–38. [Google Scholar] [CrossRef]
  26. Roessler, A.L.; Pratsinis, A.; Sahm, S.E.; Gurlo, T.; Barsan, A.; Weimar, N. Direct formation of highly porous gas-sensing films by in situ thermophoretic deposition of flame-made Pt/SnO2 nanoparticles. Sens. Actuators B Chem. 2006, 114, 283–295. [Google Scholar]
  27. Xu, H.; Liu, X.; Cui, D.; Li, M.; Jiang, M. A novel method for improving the performance of ZnO gas sensors. Sens. Actuators B Chem. 2006, 114, 301–307. [Google Scholar] [CrossRef]
  28. Kersen, U.; Holappa, L. H2S-sensing properties of SnO2 produced by ball milling and different chemical reactions. Anal. Chim. Acta 2006, 562, 110–114. [Google Scholar] [CrossRef]
  29. Viricelle, J.; Pauly, J.P.; Mazet, A.; Brunet, L.; Bouvet, J.; Varenne, M.; Pijolat, C. Selectivity improvement of semi-conducting gas sensors by selective filter for atmospheric pollutants detection. Mater. Sci. Eng. 2006, 26, 186–195. [Google Scholar] [CrossRef]
  30. Kamionka, M.; Breuil, P.; Pijolat, C. Atmospheric pollution measurement with a multi-materials sensing device. Mater. Sci. Eng. 2006, 26, 290–296. [Google Scholar] [CrossRef]
  31. Jain, K.; Pant, R.P.; Lakshmikumar, S.T. Effect of Ni doping on thick film SnO2 gas sensor. Sens. Actuators B Chem. 2006, 113, 823–829. [Google Scholar] [CrossRef]
  32. Lampe, U.; Simon, E.; Pohle, R.; Fleischer, M.; Meixner, H.; Frerichs, H.P.; Kiss, G. GasFET for the detection of reducing gases. Sens. Actuators B Chem. 2005, 111, 106–110. [Google Scholar] [CrossRef]
  33. Pijolat, C.; Viricelle, J.P.; Tournier, G.; Montmeat, P. Application of membranes and filtering films for gas sensors improvements. Thin Solid Films 2005, 490, 7–16. [Google Scholar] [CrossRef]
  34. Saukko, S.; Lassi, U.; Lantto, V.; Kroneld, M.; Novikov, S.; Kuivalainen, P.; Mizsei, J. Experimental studies of O2-SnO2 surface interaction using powder, thick films and monocrystalline thin films. Thin Solid Films 2005, 490, 48–53. [Google Scholar] [CrossRef]
  35. Kanda, K.; Maekawa, T. Development of a WO3 thick-film-based sensor for the detection of VOC. Sens. Actuators B Chem. 2005, 108, 97–101. [Google Scholar] [CrossRef]
  36. Ruiz, A.M.; Sakai, G.; Cornet, A.; Shimanoe, K.; Morante, J.R.; Yamazoe, N. Microstructure control of thermally stable TiO2 obtained by hydrothermal process for gas sensors. Sens. Actuators B Chem. 2004, 103, 312–317. [Google Scholar] [CrossRef]
  37. Kotsikau, D.; Ivanovskaya, M.; Orlik, D.; Falasconi, M. Gas-sensitive properties of thin and thick film sensors based on Fe2O3-SnO2 nanocomposites. Sens. Actuators B Chem. 2004, 101, 199–206. [Google Scholar] [CrossRef]
  38. Ivanov, P.; Llobet, E.; Vilanova, X.; Brezmes, J.; Hubalek, J.; Correig, X. Development of high sensitivity ethanol gas sensors based on Pt-doped SnO2 surfaces. Sens. Actuators B Chem. 2004, 99, 201–206. [Google Scholar] [CrossRef]
  39. Su, P.-G.; Chen, I.C. Laminating two-layer thick films structure tin oxide-based butane gas sensor operating at low temperature. Sens. Actuators B Chem. 2004, 99, 304–309. [Google Scholar] [CrossRef]
  40. Wagh, M.S.; Patil, L.A.; Seth, T.; Amalnerkar, D.P. Surface cupricated SnO2-ZnO thick films as a H2S gas sensor. Mater. Chem. Phys. 2004, 84, 228–233. [Google Scholar] [CrossRef]
  41. Choi, U.-S.; Sakai, G.; Shimanoe, K.; Yamazoe, N. Sensing properties of SnO2-Co3O4 composites to CO and H2. Sens. Actuators B Chem. 2004, 98, 166–173. [Google Scholar] [CrossRef]
  42. Chu, X.; Cheng, Z. High sensitivity chlorine gas sensors using CdSnO3 thick film prepared by co-precipitation method. Sens. Actuators B Chem. 2004, 98, 215–217. [Google Scholar]
  43. Chu, X. Dilute CH3SH-sensing characteristics of BaSnO3 thick film sensor. Mater. Sci. Eng. B 2004, 106, 305–307. [Google Scholar] [CrossRef]
  44. Zhu, B.L.; Xie, C.S.; Wang, W.Y.; Huang, K.J.; Hu, J.H. Improvement in gas sensitivity of ZnO thick film to volatile organic compounds (VOCs) by adding TiO2. Mater. Lett. 2004, 58, 624–629. [Google Scholar] [CrossRef]
  45. Chu, X.; Zheng, C. Sulfide-sensing characteristics of MFe2O4 (M = Zn, Cd, Mg and Cu) thick film prepared by co-precipitation method. Sens. Actuators B Chem. 2003, 96, 504–508. [Google Scholar]
  46. Noh, W.; Shin, Y.; Kim, J.; Lee, W.; Hong, K.; Akbar, S.A.; Park, J. Effects of NiO addition in WO3-based gas sensors prepared by thick film process. Solid State Ionics 2002, 152–153, 827–832. [Google Scholar] [CrossRef]
  47. Solis, J.L.; Saukko, S.; Kish, L.; Granqvist, C.G.; Lantto, V. Semiconductor gas sensors based on nanostructured tungsten oxide. Thin Solid Films 2001, 391, 255–260. [Google Scholar] [CrossRef]
  48. Arshak, K.; Cunniffe, C.; Moore, E.; Cavanagh, L.; Harris, J. A novel approach to electronic nose-head design, using a copper thin film electrode patterning technique. In Proceedings of the 28th International Spring Seminar on Electronics Technology, Wiener Neustadt, Austria, 19–22 May 2005; pp. 185–190. [Google Scholar]
  49. Girish, K.M.; Naik, R.; Prashantha, S.C.; Nagabhushana, H.; Nagaswarupa, H.P.; Raju, K.A.; Nagabhushana, B.M. Zn2TiO4: Eu3+ anophosphor: Self explosive route and its near UV excited photoluminescence properties for WLEDs. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2015, 138, 857–865. [Google Scholar] [CrossRef] [PubMed]
  50. Siriwong, C.; Tamaekong, N.; Phanichphant, S. Characterization of single phase Pt-doped Zn2TiO4 nanoparticles synthesized by flame spray pyrolysis. Mater. Lett. 2012, 68, 97–100. [Google Scholar] [CrossRef]
  51. Siriwong, C.; Phanichphant, S. Flame-made single phase Zn2TiO4 nanoparticles. Mater. Lett. 2011, 65, 2007–2009. [Google Scholar] [CrossRef]
  52. Arshak, K.; Gaidan, I. Development of an array of polymer/MnO2/Fe2O3 mixtures for use in gas sensing applications. Sens. Actuators B Chem. 2006, 118, 386–392. [Google Scholar] [CrossRef]
Figure 1. Schematic indicating the flow of the implemented experimental procedure steps.
Figure 1. Schematic indicating the flow of the implemented experimental procedure steps.
Sensors 17 01995 g001
Figure 2. Configuration of the ZnO/ TiO2 sensors.
Figure 2. Configuration of the ZnO/ TiO2 sensors.
Sensors 17 01995 g002
Figure 3. SEM images of TiO2/ZnO mixed powder (A,C,E) and screen-printed sensing material (B,D,F) for Sample 1–3 respectively.
Figure 3. SEM images of TiO2/ZnO mixed powder (A,C,E) and screen-printed sensing material (B,D,F) for Sample 1–3 respectively.
Sensors 17 01995 g003
Figure 4. The XRD patterns from 10° to 70°, 2θ, for TiO2/ZnO samples, after being heated at 1250 °C for 5 h.
Figure 4. The XRD patterns from 10° to 70°, 2θ, for TiO2/ZnO samples, after being heated at 1250 °C for 5 h.
Sensors 17 01995 g004
Figure 5. The response of the Zn2TiO4 sensors to propanol at concentration range 500–3000 ppm increasing with a step size of 500 ppm at room temperature.
Figure 5. The response of the Zn2TiO4 sensors to propanol at concentration range 500–3000 ppm increasing with a step size of 500 ppm at room temperature.
Sensors 17 01995 g005
Figure 6. The response of the Zn2TiO4 sensors to propanol at a concentration range of 2500–5000 ppm at room temperature. (A) The response of the sensors with time (Sec.) and (B) The response of the sensors with gas concentration (ppm).
Figure 6. The response of the Zn2TiO4 sensors to propanol at a concentration range of 2500–5000 ppm at room temperature. (A) The response of the sensors with time (Sec.) and (B) The response of the sensors with gas concentration (ppm).
Sensors 17 01995 g006
Table 1. List of selected sensing materials for sensing different gases.
Table 1. List of selected sensing materials for sensing different gases.
Sensing MaterialsSensitive GasesYear/Reference
ZnOH2S2017 [9]
ZnO–SnO2O32016 [24]
TiO2NO22015 [10]
Zn2TiO4C2H5OH2015 [5]
ZnONO22013 [14]
Zn/Zn2SnO4 + SnO4CO/C3H82013[17]
TiO2Chloroform2014 [15]
TiO2 and ZnOC2H5OH2012 [13]
TiO2-ZnONO22010 [12]
ZnOC2H5OH2010 [25]
SnO2 and Pt/SnO2CO2006 [26]
ZnOC2H5OH and Acetone2006 [27]
SnO2H2S and CO2006 [28]
SnO2O3, COand NO22006 [29]
SnO2O3 and NO22006 [30]
SnO2/Al/NiLPG gas2006 [31]
SnO2 or Ga2O3CO and CO22005 [32]
SnO2H2, C2H5OH CH42005 [33]
SnO2CO and CO22005 [34]
WO3Hydrocarbon gases2005 [35]
TiO2CO2004 [36]
Fe2O3–SnO2NO2 and C2H5OH2004 [37]
Pt-SnO2C2H5OH2004 [38]
SnO2C4H102004 [39]
SnO2–ZnO and SnO2–ZnO–CuOH2S LPG, NOx, CO2, CO and CH42004 [40]
SnO2–Co3O4CO and H22004 [41]
CdSnO3Cl22004 [42]
BaSnO3H2S, CH3SH2004 [43]
ZnO–TiO2Alcohol, Acetone, Benzene, Toluene and xylene2004 [44]
MFe2O4H2S, CH3SH2003 [45]
NiO-doped WO3NO22003 [46]
WO3H2S2001 [47]
Table 2. Description of powder samples prepared for developing screen printing paste.
Table 2. Description of powder samples prepared for developing screen printing paste.
SampleTiO2 (Mwt %)ZnO (Mwt %)
Sensor 17525
Sensor 25050
Sensor 32575

Share and Cite

MDPI and ACS Style

Gaidan, I.; Brabazon, D.; Ahad, I.U. Response of a Zn2TiO4 Gas Sensor to Propanol at Room Temperature. Sensors 2017, 17, 1995. https://doi.org/10.3390/s17091995

AMA Style

Gaidan I, Brabazon D, Ahad IU. Response of a Zn2TiO4 Gas Sensor to Propanol at Room Temperature. Sensors. 2017; 17(9):1995. https://doi.org/10.3390/s17091995

Chicago/Turabian Style

Gaidan, Ibrahim, Dermot Brabazon, and Inam Ul Ahad. 2017. "Response of a Zn2TiO4 Gas Sensor to Propanol at Room Temperature" Sensors 17, no. 9: 1995. https://doi.org/10.3390/s17091995

APA Style

Gaidan, I., Brabazon, D., & Ahad, I. U. (2017). Response of a Zn2TiO4 Gas Sensor to Propanol at Room Temperature. Sensors, 17(9), 1995. https://doi.org/10.3390/s17091995

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop