Article

Utilization of Multisensor Data Fusion for Magnetic Nondestructive Evaluation of Defects in Steel Elements under Various Operation Strategies

Department of Electrical and Computer Engineering, Faculty of Electrical Engineering, West Pomeranian University of Technology, Szczecin, al. Piastow 17, 70-310 Szczecin, Poland
Sensors 2018, 18(7), 2091; https://doi.org/10.3390/s18072091
Submission received: 3 May 2018 / Revised: 17 June 2018 / Accepted: 26 June 2018 / Published: 29 June 2018
(This article belongs to the Section Physical Sensors)

Abstract

:
Increasing the number of inspection sources creates an opportunity to combine information in order to properly set the operation of the entire system, not only in terms of such factors as reliability, confidence, or accuracy, but inspection time as well. In this paper, a magnetic sensor-array-based nondestructive system was applied to inspect defects inside circular-shaped steel elements. The experiments were carried out for various sensor network strategies, followed by the fusion of multisensor data for each case. In order to combine the measurements, first data registration and then four algorithms based on spatial and transformed representations of sensor signals were applied. In the case of spatial representation, the data were combined using an algorithm operating directly on input signals, allowing pooling of information. To build the transformed representation, a multiresolution analysis based on the Laplacian pyramid was used. Finally, the quality of the obtained results was assessed. The details of algorithms are given and the results are presented and discussed. It is shown that the application of data fusion rules for magnetic multisensor inspection systems can result in the growth of reliability of proper identification and classification of defects in steel elements depending on the utilized configuration of the sensor network.

1. Introduction

There are currently two main aspects of newly introduced technological solutions: production and quality control. The technology used must meet high quality standards. By “quality”, we mean a high discrimination rate between possible material states, which, in consequence, allows highly effective correct identification of the actual condition and a high level of product safety. In practice, this involves the need to develop integrated inspection instrumentation coupling multisource systems and advanced methods of processing and data fusion [1,2,3,4,5,6,7,8,9,10,11,12,13,14].
According to the fact that most of the current structures are made of conductive and magnetic materials, the use of electromagnetic testing methods becomes a natural solution. The methods can be utilized to inspect surface and subsurface regions as well as deeper parts of the material for the detection of cracks or any inhomogeneity affecting the electromagnetic properties of the material. One of the most common electromagnetic nondestructive testing techniques used in the industry is magnetic flux leakage (MFL). The objective of the method is to detect the magnetic field over the inspected area which leaks from the material when a difference in magnetic conditions (permeability) appears, caused by a defect’s occurrence [1]. It finds its application in the inspection of any object with ferromagnetic properties. It is frequently utilized for the inspection of pipelines or tubes [1,4,5,6,7,8,15,16], train wheels and axles or rail tracks [9,17,18,19], steel wire ropes [10,11,20], storage tanks [15,21], or steel construction elements [2,12,22,23,24]. The method is suitable for detecting various types of surface, subsurface, and surface-breaking deeper defects in magnetic materials such as metal loss [2,10,11,20], fatigue damage cracks [1,2,3,5,8,9,16], pitting corrosion [1,2,5,6], or plastic deformation [1,15,24,25]. The relatively small dimensions of the detectors of leaking magnetic flux allow us to apply the method to examine both the external sides [1,2,3,4,5,9,10,11] of the tested objects and the internal sides such as the inner wall of a pipe or hollow axle [1,6,8,16,19]. One of the main advantages of the method is the lack of need for direct contact between the inspected element and the sensing device. Therefore, it can be applied even when the material is covered with paint or dust. One of the main challenges in the construction of measuring systems is the magnetization section. They can be built with a magnetizing coil generating an alternating (AC) or direct (DC) field or, alternatively, with a permanent magnet [1,4]. The AC source, due to the skin effect, is mostly used for surface condition monitoring. More frequently, the DC field is utilized, as it allows deeper inspection of the material. On the other hand, the sensing can be affected by some disturbance conditions [1,4,10]. Nevertheless, during the design and further inspection process, orientation of defects, which can possibly occur in the tested element in reference to the direction of the magnetizing field, should be considered. The sensitivity of the method strongly depends on the degree of disruption of the free flow of the magnetic field lines caused by anomalies in the material. Thus, detection of defects aligned parallel to the field lines path is restricted and can strongly affect the proper indication. One of the main limitations of the method is the scanning speed [1,9]. Utilization of a high testing speed can result in eddy currents affecting testing. Therefore, due to the simultaneous desire to increase the reliability and speed of conducted inspections, as well as to gain complementarity and completeness of the acquired examination information, there currently arises a strong need to design and build complex and distributed multiple homogenous or heterogeneous sources network for nondestructive control systems [3,12,17,18,19,22,23,25,26].
In case of industrial magnetic flux leakage inspection systems, the array of homogenous sensing elements has been most frequently utilized for inspection of steel wire rope [4,10,11] or the inner and outer wall of pipelines or any circle-shaped steel object [1,4,5,6]; however, usage for constriction condition monitoring has also been common [2,3,12,15]. In the majority of cases, the sensors were arranged in linear arrays [2,4,5,10,11,15] placed in the magnetic field and aligned parallel [2,4] or perpendicular [5,6,10,11] to the field lines, wrapping the surface of the material. During inspection, the arrays observed one or all three components of the magnetic field (tangential x and y and normal z). The scanning method was adjusted to the type of the tested element and the size of the device in reference to the size of the objects. Usually the array was moved linearly along the scanning direction [2,8,10,11]. In [11], a flexible GMR-type (giant magnetoresistive) sensor array fixed within a pair of saddle-type magnetizing coils was used for the detection of defects on the outer surface of steel track rope. The tested object was magnetized along the axial direction and the array was used to sense the axial component of leakage flux during linear movement. The system performance was validated using artificial defects (with length of few to few tens and depth of 2 to around 5 mm) made in the circumferential and axial directions. It showed some possibility for identifying the spatial information and a higher discrimination level for circumferentially aligned notches. A similar solution of array general construction was presented in [10]. Utilization of TMR-type (magnetoresistive tunnel) devices allowed high sensitivity even for defects with depth and length of 0.5 mm. However, the accuracy of presented solutions along with the scanning mode depends on the distance between two successive sensing elements and can result in misdetection of relatively small defects. A possible enhancement of the achieved effectiveness could be reached by a set of two shifted sections of sensor arrays following each other, like that demonstrated in [8]. In [9], the three sections, each comprising 16 Hall sensors, observing different components of a vector field and placed one by another were used for the detection of multiple cracks in steel elements of rail tracks. The monitoring of all three components allowed the evaluation of the shape and orientation of multiple cracks, but was not efficient in depth assessment. In the case of round-shaped examined elements, when the array length was less than the circumference of the object, the helical rotation mode was also applied in order to cover a greater inspection area [4,5,6] and preserve relatively high inspection speed. Nevertheless, in the majority of proposed solutions, in order to obtain a high inspection speed, the defects were detected each time only by a single sensor or a pair of neighbouring sensors. This could result in achieving restricted inspection resolution when a defect crosses the array line at the midpoint between two neighbouring sensing elements [10]. Furthermore, disrupted or incorrect indications provided by one element in the sensor array can also significantly limit the whole system’s defect detection ability and efficiency. Thus, the construction of the sensor array not only affects the examination speed but also plays a crucial role in the definition of the overall system’s performance.
Generally, under the concept of a multisensor inspection system, various aspects, such as risk of faulty indication, spatial coverage, imprecision, and uncertainty, should be considered [27]. In such cases a multisensor data fusion methodology appears as a natural solution of the combined problem. Such multisensor structures permit the adjustment of the sensing unit configuration under various terms including inspection area range and coverage of a single sensor, acquisition time, or reliability of results [27,28,29,30]. Thus, application of a data fusion procedure allows us to simultaneously balance the operation of the system in reference to the mentioned factors. Furthermore, it is possible to achieve greater robustness and reliability, greater spatial coverage and a gain of higher resolution, and an increase of confidence and decrease of uncertainty at the same time. Therefore, the choice of scanning mode, in the case of multisensor solutions, is an important factor that should be taken into account when assessing the relationship between system reliability and speed of inspection. According to [31], the sensors can operate under three major configurations: competitive, complementary, or cooperative. The array is running in competitive mode when each sensing element provides independent information about the same range of the inspected object and the combined information is building a redundant image. In fact, this configuration allows us, at the end, to reduce the risk of incorrect indication caused by failure of one sensor by minimizing its influence on the final result or even excluding it from building the image. In consequence, this might result in an increase in the reliability, accuracy, or confidence of the data. On the other side of configuration modes, the complementary one arises. Utilization of this strategy means that each sensor is monitoring a different selected part of the examined object and collected information by all elements is combined to provide a broader image of the tested material. Finally, the cooperative mode refers to usage of a set of sensors to deliver one different aspect of the same object and create, in that manner, a more comprehensive image of the inspected material. The described categories are not mutually exclusive and a set of two sensors could be operating within the complementary, competitive, or cooperative mode in a different inspection range. Therefore, taking into account the specific feature of operation of the measurement system to be optimized, it is possible to apply various strategies. Regardless of the final configuration of the sensor array, the use of multisensor collection and data fusion allows us to gain an improvement in the general system performance.
Some initial consideration of multisensor data fusion under the competitive mode was previously presented in [26]. In the current paper, taking into consideration all described aspects, multisource data fusion is carried out on multisensor array data obtained during inspection of defects in a circular-shaped tube sample under different terms. Several strategies of sensor array operation are examined and the resulting performance is evaluated. Under each considered configuration, information gathered from the sensor array is fused using different fusion algorithms. The aim of the process was to gain a higher quality of inspection results and thus increase the possibility of obtaining correct indication and evaluation of defects, balancing reliability and inspection time. During the integration of data, several aspects were considered. First, multisensor data registration is carried out. Then, the applied fusion algorithms are described and the obtained results discussed. Finally, the performance is evaluated and the conclusions are presented.

2. Multisensor Data Source and Fusion Strategies

In order to process the experiments, the magnetic sensor array data were used. The data were acquired during inspection of a circular-shaped tube magnetic steel sample with six artificial defects: d1d6 (Figure 1). All were made on the internal wall of the sample using the EDM (Electro Discharged Machined) method in two main orientations with reference to the axis of symmetry (Figure 1c): in the axial (d1, d3, and d5) and circumferential directions (d2, d4, and d6). The defects had the same length of 5 mm and width of 0.5 mm while the depths varied: 0.5 mm for d3 and d4, 1 mm for d1 and d2, and 2 mm for d5 and d6. The data were acquired under the DC magnetic field conditions. Before scanning, the internal surface of the sample was magnetized in the axial direction, by moving along its axis l the permanent magnet with magnetic poles placed in the axial direction. A visualization of the course of the obtained leakage field vectors over the surface of the inner wall, in the vicinity of defects located axially and circumferentially, is shown in Figure 2. It can be noticed that the circumferential defects are located perpendicularly to the direction of the field lines, hence causing greater disturbance of the field. As a result, a higher indication value of this type of defect is achieved. The residual flux leakage field is then measured by an array of 3-axis AMR-type (anisotropic magnetoresistive) sensors (Figure 1a,b). The sensors were fitted within a hole of 30 mm diameter in equally spaced positions located every 45 degrees on the circumference, which resulted in having 8 sensors in an array. Each sensor was measuring three components of magnetic field: two tangential to the surface (at a point) of the sample, along Vx and across Vy the magnetizing stream lines, and the normal Vz.
During the data collection, the array was first moved by linear steps Δl along the axial direction l and data acquisition was then carried out during rotation (circumferential direction α) by a given angle Δα (Figure 1a). In order to evaluate the performance under different operation strategies, the range of the rotation angle Δα was changed during the experiments from 45 up to 360 degrees in steps of 45 degrees. This enabled one to obtain a different spatial range of data for each sensor and, in consequence, operation of the array under competitive (Δα equal to 360°), cooperative, or complementary (Δα equal to 45°) conditions. When the rotation angle was equal to 360 degrees, each sensor was moved over the whole inspection area (full rotation) and thus provided data corresponding to other sensors’ areas, which was shifted from sensor to sensor by 45 degrees in the angular direction (Figure 3a). On the opposite side (in terms of the scanning angular range) is the case of rotating the sensor array by only 45 degrees (Figure 3b). In this situation, each sensor observes only a selected—not covered by any other sensor—part of the examined sample’s area. This configuration results in the complementary mode of the sensor array. When the rotation angle was larger than 45 and less than 360 degrees, the multisensor unit could operate in cooperative mode, allowing both competition and cooperation of the sensor set. In Figure 3c, a schematic visualization of the array configuration obtained for a rotation angle equal to 90 degrees is shown. In this example, sensors s1 and s2 cover the angular areas defined by Δα1 and Δα2 ranging from 0 to 90 and from 45 to 135 degrees, respectively. Considering only those two sensors’ data for angles lower than 45 and greater than 90 degrees, the array was operating in complementary mode. In the middle range (45–90 degrees), the competitive strategy could be applied. Nevertheless, no matter what the applied Δα range, the scanning resolution was always equal to 0.1 mm and 0.1 degree. A detailed description of the construction of the multisensor array used as well as the sample can be found in [19]. The diagram of the whole process for defect evaluation, applied regardless of the utilized operation mode, is presented in Figure 4. First, the sensors’ data were matched and transformed into the same representation space and output value dynamic range (data registration stage). Then, data fusion was processed and, finally, the evaluation of the obtained results was carried out. The selected results of measurements of all three components measured by one sensor obtained for defect d5 and d4 with respective depths of 2 mm and 0.5 mm are presented in Figure 5. Taking into consideration the depths, the defects represent two extreme detection cases: the easiest and the hardest, respectively. Each measured field component allows us to gain different information about the defect, such as the length, width, and depth [12,18,19,23]. However, it can be noticed that, especially for shallower defects, beside the visible indication of signals in the faulty area, in other parts, the signal level is also high; this can result in misclassification of the actual state. Therefore, the need for data fusion arises.

3. Spatial Alignment Evaluation and Data Registration

Before processing the fusion, the data registration procedure was carried out. The functional block diagram of the registration algorithm is presented in Figure 6. First, in order to transform acquired signals into a common coordinate system, the estimation of the angular δϕ and linear δl misalignment of each sensor in the array must be carried out. For that need, the measurements for defect d6 (allowing archiving of the highest level of signal corresponding to the defect) were processed under the competitive mode. In consequence, data were acquired in the full angular range for all 8 sensors. Then, for the misalignment evaluation, the analysis of sensor vectors V(l, α) = (Vx(l, α), Vy(l, α), Vz(l, α)) was carried out. First, based on the location of characteristic values of the components’ signals in the vicinity of the defect d6, the control points cp were determined individually for each sensor. Then, the spatial relationship between defined cp for each sensor in reference to the ones for sensor s5 was analyzed. The s5 sensor was chosen as it was placed in the middle of the multisensor array, so for sensors of number lower than 5, the shifting angle was positive and for ones greater than 5, it was negative. The results of the angular misalignment evaluation are presented in Figure 7. According to the results, it can be noticed that the asymmetry of the sensor allocation cannot be neglected. The highest angular misalignment is around 4% which corresponds to 1.8° while the linear misalignment is 1 mm. Taking into consideration the diameter (close to 29.5 mm) of the sensor array, the angular misalignment δϕ can be recalculated (multiplying by (π/180) R, where R is the radius) and expressed in corresponding mm scale. This allowed the comparison of the allocation error with the dimensions of possible defects. The estimated value of misalignment recalculated to arc distance was less than 0.5 mm, which can be assessed as fairly acceptable for industrial applications.
In the second step, the sensitivity range of sensors in the array was estimated. During this stage, not only the gain and the offset but also the difference in distance between each sensor and the surface of the material should be taken into account. Considering the gain tolerance and linearity ranges of the sensors and the experimental results, the calibration coefficients were computed, allowing one to obtain similar output signal dynamic ranges for each sensor under the same measuring conditions. Finally, the data transformation into common representation was carried out. The selected results (obtained for all sensors) of vector norm values obtained for all sensors are presented in Figure 8, and those for a single sensor for all field components and the norm value are in Figure 9. It can be seen (Figure 8) that the applied process allowed one to obtain corresponding spatial as well as sensitivity ranges for each sensor. The spatial and sensitivity transformation information was also utilized in the case of data acquired under complementary and cooperative modes. The result of the registration process obtained for Δα values equal to 45 and 90 degrees are presented in Figure 10. Finally, the achieved registered signals of all components were then used as input for the data fusion algorithms.

4. Data Fusion Algorithms

The utilization of a multisensor array gives the advantage of limiting the influence of unwanted distortions on the observation of any single sensor, thus affecting the efficiency of proper defect indication [30,31,32,33,34,35,36,37]. In order to combine information provided by all sensors, data fusion algorithms were utilized. The block diagram of the general data fusion scheme is presented in Figure 11. First, the registered vector v data of all sensors were fused. The procedure was carried out separately for each component of v resulting in common representations of vx, vy, and vz components (Stage I of the data fusion algorithm). Then, taking into consideration that each component can provide one with different complementary data about the detected defect (which can enhance the efficiency of defect indication), the final integration was performed by computing the norm value of all components’ fused distributions (Stage II of the data fusion algorithm).
In order to process the Stage I algorithms (Figure 12), spatial and transformed representations [31,32,33,35] of sensors’ signals allowing pooling of information were applied. The spatial framework can be expressed by
vdf(l, α) = fdf (v1(l, α), v2(l, α), , v8(l, α))
while the transformed one can be given in the form
vdf(l, α) = T−1{fdf (T{v1(l, α)}, T{v2(l, α)}, …, T{v8(l, α)})}
where fdf, T, and T−1 respectively denote data fusion, transform, and inverse transform operators, and vdf is the fused distribution of the given component. Finally, in order to carry out the integration, four fusion rules were introduced considering spatial vectors, spatial information, and multiresolution representations of multisensor data.

4.1. Spatial-Vector-Based Data Fusion (DFvec Algorithm)

Taking into consideration that the transducer consists of sensors of the same type, each sensor should acquire similar observations in reference to common global position. Therefore, a signal’s representation in terms of specific global position on the measuring area is represented by a common vector for all sensors defined in 8-dimensional feature space as
v(l, α) = (v1(l, α), v2(l, α), , v8(l, α)).
If any sensor or group of sensors indicates a defect, the length of the vector would change. The rate of variation grows with the number of sensors that provide the indication information. As a result, the common representation spatial vector can be defined as
  v df ( l ,   α ) = v 1 ( l ,   α ) 2   +     +   v 8 ( l ,   α ) 2 .
Finally, results of spatial vectors for three components were obtained: vxdf(l, α), vydf(l, α), and vzdf(l, α).

4.2. Direct Spatial Multisensor Data Fusion

In the direct spatial fusion, the sensors’ input signals are integrated using localized spatial features. In this process, three aspects of multisensor perception for state evaluation can be considered: conjunctive, disjunctive, and compromise [30].

4.2.1. Conjunctive and Compromise Concepts (DFSF Algorithm)

The first concept leads to building a fused representation including all input information, regardless of the information importance of each source. This can be simply expressed by
  v df ( l ,   α ) = v n ( l ,   α ) .
The first approach can be complemented by taking into account the significance of information from individual sources, also called “building a compromise”. According to Equation (5), the expression can be defined as
  v df ( l ,   α )   = 1 N i = 1 N w i v i ( l ,   α )
where wi stands for the weight of the given ith source referring to its information content (which can be described by various measures allowing quantification of data) and N is the number of sources. This definition in terms of performance evaluation can be also understood as a linear opinion pool (LOP) approach [32]. This strategy is commonly utilized. The weighted sum of data gathered by similar sources is frequently utilized in signal fusion algorithms [33,34,35,36]. The main objective is to build a common representation enhancing the overall information level. One of the most straightforward fusion operators of this type is simple superposition by averaging of the inputs. Then, all source weights are equal. In other cases, the most important aspect is to obtain the weight coefficient representing the information level supplied by the specific source. The applied coefficient computation algorithm can be based on classical statistics (e.g., variance or standard deviation) or on analysis of information content based on, e.g., principal component analysis (PCA) [34] or spatial frequency (SF) analysis [37,38]. In this paper, the signal processing was carried out for each sensor data and the overall level of information acquired by a specific sensor was estimated. For that need, a spatial frequency SF-analysis-based algorithm was utilized in order to compute the weights corresponding to the information level provided by input sources. In order to process the calculation, first the row (RF) and column (CF) frequencies and then SF were computed based on the following expressions [32,34]:
  R F =   1 P Q p = 1 P 1 q = 2 Q 1 [ v ( p , q ) v ( p , q 1 ) ] 2
  C F =   1 P Q p = 1 P 1 q = 2 Q 1 [ v ( p , q ) v ( p 1 , q ) ] 2
  S F = R F 2 + C F 2
  w i = S F i S F
where P and Q refer to number of rows and columns of analyzed data v, i = 1, …, N, and N is the number of data sources. The obtained weights wi were then used to obtain the fused data for each component (DFSF algorithm).

4.2.2. Disjunctive Concept (DFIOP Algorithm)

The aim of the second concept is to maintain common information in the fused data, i.e., that appearing in all the component sources, and to suppress mutually different information at the same time. In this case, the expression can be given as
  v d f ( l ,   α ) = v n ( l , α )
Considering the described properties and assuming that the information conditioned on the measurement set is independent, this strategy can be defined also as an independent opinion pool (IOP). This concept was utilized in this paper to depict the areas of high confidence of indication (DFIOP algorithm).

4.3. Multiresolution-Analysis-Based Data Fusion (DFPYR Algorithm)

Multiresolution or multiscale analysis (MRA) is a well-known transformation framework in signal (or image) fusion processing. Its main idea is to decompose the input data into successive subsets (layers) of different frequency and resolution representations [33,34,39]. In reference to Equation (2), MRA-based data fusion concerns two aspects: first is the decomposition algorithm, while the second one is the fusion rule [28,35,39]. Commonly utilized transformations are based on wavelet, contourlet, or, recently, shearlet decomposition. Resulting subsets represent details of input sources at different scales and orientations. The other type of processing technique is pyramid decomposition. In this case, each layer is filtered and downsampled by a factor of 2 from the representation of a previous one. The decomposition process can be applied utilizing different transformation algorithms such as contrast, Gaussian, or Laplacian filtering [28,33,40]. The main idea of the multiscale fusion scheme is to combine the information at different detail levels in order to preserve the information of different scales. Then, the multiresolution integrated data is reconstructed to obtain the final fusion result.
In this paper, a Laplacian pyramid was utilized to achieve the multilayer representation of data for each sensor [32,38,39]. In order to process the Laplacian pyramid transformation, first, the original data vpyr{0} were decomposed into a 5-layer set vpyr containing sequentially reduced representations. The reduction operation is a recursive (level-to-level) averaging process carried out according to the following expression:
  v p y r { m } ( p , q ) = a = 2 2 b = 2 2 w ( a , b ) v p y r { m 1 } ( 2 p + a , 2 q + b )
where m refers to a given layer and is within the range 0 < m < 5, p and q are indices of rows and columns of a given layer defined within the range 0 ≤ p < Pm, 0 ≤ q < Qm, and Pm and Qm are the number of rows and columns of the mth-level representation. The utilized weight w kernel width was equal to 5, which allows one to obtain balance between the filtering conditions and computational time. The kernel is defined by the set {0.25-cw/2, 0.25, cw, 0.25, 0.25-cw/2}, where cw is a center weight. The inverse operation (expansion) at a given level is obtained by interpolating new values between the given ones according to the expression
  v p y r { m + 1 } ( p , q ) =   4 a = 2 2 b = 2 2 w ( a ,   b ) v p y r { m } ( p a 2 , q b 2 ) .
After decomposition, the Laplacian pyramid set Lvpyr{0}, …, Lvpyr{4} is calculated as a sequence which each level is the difference Lvpyr{m} = vpyr{m} − Expand (vpyr{m + 1}). The original data distribution can be achieved by expanding and summing operations of the Lvpyr set.
An exemplary view of representations obtained for successive layers of a selected sensor component x distribution (the resolution is decreasing from the left-hand side to the right-hand side) is presented in Figure 13. One can notice that the information content about the inspected defect is the highest for the three middle layers. It is clear that the distributions on both the first and the last layer provide ambiguous data, which may have a significant influence on further identification processes. Considering that the characteristic of MFL inspection signals in the vicinity of the defects rather represents the middle spatial frequency range, the highest signal representation could be neglected. Similarly, the lowest one can present not only information about the defect but also a high level of low-frequency background noise. Finally, the fusion was processed for the middle representation layers (as the first and the last layers of the representations were filtered out). The fusion at a specific layer was performed under the LOP strategy described earlier by computing the average signal, and the reconstruction process was then carried out.

5. Data Fusion Results

The selected results obtained during the fusion process at both stages (Figure 11, results of Stage I: vxdf, vydf, vzdf and Stage II: vdf) carried out using all four fusion rules are presented in Figure 14, Figure 15 and Figure 16. First, the results obtained under competitive operation of the multisensor array were analyzed (Figure 14 and Figure 15). Considering the outputs of DFvec and DFSF, one can see that both show relatively similar information content (similar characteristics of distributions). The major difference between the rules concerns the results’ dynamic range, as a significant gain of DFvec distribution values in reference to DFSF ones can be noticed. Thus, it can be stated that DFvec allows us to obtain qualitatively slightly better discrimination and defect indication rate, which can be observed especially for shallower defects (Figure 14e).
Generally, on the basis of the presented results, the greatest growth of difference between the defect response signal and the background signal is qualitatively observed for the DFIOP algorithm. It can be noticed that the clear indication of flaw edges is possible. This can be utilized in further processing of the defect identification process and lead to the enhancement of proper indication confidence and accuracy. However, it should be noted that in the case of a lower level of defect response signals (such as that observed for shallower axial defects), the background signals can be enhanced by a similar factor and the defect detection process can lead to an increase in the probability of false alarm (PFA) as well (case of d1 and d3, Figure 15a,c). In reference to this conclusion, the highest reduction of the influence of background signals on results was achieved for the DFPYR rule. Once again, the greatest advantage can be seen for shallower defects. However, for each defect it is possible to notice a significant reduction of noise background when comparing with the DFSF and DFvec results.
According to the utilized magnetization conditions, a worse discrimination ability was obtained for axially aligned defects (d1, d3, and d5), as they cause much lower disruption of the free flow of magnetic field in the examined element (Figure 15a,c,e). Nevertheless, also for this type of defect, it was clearly visible that there was an advantage in using the DFPYR fusion scheme.
However, before further defect assessment procedures, the orientation of the defect should be evaluated first, as its alignment with respect to the magnetizing stream lines strongly affects the level of leaking magnetic flux and, thus, the indication process. The relationship between the depth and the signal levels is different for axial and circumferential defects.
In order to evaluate the efficiency of the fusion rule under different operation strategies, experiments were undertaken for different values of rotation angle Δα. Selected results obtained for Δα equal to 45 and 90 degrees during the inspection of defect d4 are presented in Figure 16. In the first case, the multisensor array was working in the complementary mode, as each sensor was providing unique data about a selected area of the examined object. Therefore, the application of algorithms DFvec and DFSF leads to the same results due to the processing of the fusion procedures, for each 45 degrees, from only one source of data (Figure 16a,b). On the same basis, the IOP strategy was not possible to carry out as it requires at least two sources for each part of the inspected area. In that situation, the greatest advantage can be observed in the case of the DFPYR fusion algorithm. In the case of experiments carried out for Δα equal to 90 degrees, all fusion schemes were carried out (Figure 16d–g). Even though the source number was increased only to two, a slight reduction of the background signal level could be noticed. From the qualitative evaluation of results obtained for both strategies, it can be seen that the level of the background signal is locally higher (particularly in the noise areas); this can be especially observed for the DFvec and DFSF results.

6. Evaluation of Data Fusion Results

In order to quantitatively evaluate the performance of the applied data fusion schemes, two quality factors were computed: entropy E and signal-to-noise ratio SNR [32,34,38]. The entropy is defined as
  E = k = 1 K H v ( k ) log 2 H v ( k )
where Hv is the normalized histogram of distribution v and K is the number of histogram bins. It is expressing the information contribution of data and is related with the frequency of change in v. It is high for signals with high information content. However, it is also strongly correlated with the noise level and unwanted fluctuation of the signal. In the particular nondestructive application presented in this paper, the defect region covers only a relatively small part of the inspected area. Thus, it is expected that the signal variation would occur only in that region. Therefore, it can be understood that the lower the entropy value is, the better the performance of the fusion scheme. The SNR metric measures the ratio between useful (signal in defected area vsignal) and unwanted signals (background signal level vnoise):
  S N R   = 20 log 10 v signal v noise .
The SNR was calculated based on two areas: the area where the defect occurred and an area without the defect. vsignal and vnoise represent the mean values of signals in the areas where the defect occurred and without the defect, respectively. Both were obtained utilizing the thresholding operation, where the threshold value was calculated based on the values range in the defected area. In this case, a higher SNR value means that the discrimination ability grows.
The achieved values obtained for single-source signals and for the fusion algorithms under the competitive strategy for norm value (Stage II: E, SNR) are presented in Table 1 and Table 2.
The obtained measures of E and SNR confirmed that by carrying out the applied data fusion schemes, an increase in the signal quality can be achieved. One can see a quantitative gain of information when comparing the results of raw signals v and the fused vdf ones of the second stage. The lowest change in E (drop of value) and SNR (increase in value) could be noticed in the case of DFvec and DFSF fusion schemes. Significant variation of values is visible for DFPYR and the greatest can be observed for DFIOP. However, it should be underlined that even though the DFIOP scheme results in significant reduction of noisy content, it can also affect the signal level of the defect area. As the algorithm allows us to maintain the common part of the data in the fused result and to suppress mutually different parts at the same time, both background noise and the defect signal level and area can be reduced. From that point of view, the utilization of the DFPYR rule seems to be the most advantageous. In order to assess the change of the performance with respect to the operation strategy, the E and SNR were calculated for the results of DFPYR and DFIOP algorithms achieved for different ranges of rotation angle Δα. For Δα equal to 360 degrees, the sensors were working in competitive mode, while for 45 degrees, they were in complementary mode. All middle ranges resulted in usage of the cooperation strategy. By successively adding 45 degrees to the previous range of rotation angle, the number of sensors covering each 1/8 of the full rotation area is also increased by one. The results were normalized to the value obtained for the competitive mode and presented in the form of the plot in Figure 17. The obtained results confirmed that utilization of a greater number of sensors for processing the fusion scheme allows one to obtain a higher quality (confirmed by better levels of both evaluation factors); however, a higher gain in effectiveness can be noticed for harder indication conditions such as in the case of axial defects. It can be noticed that only in the case of the d3 defect is there a slight decrease of the SNR value for lower angular range. The defect d3 is an axial-type defect, which under the utilized magnetizing conditions is harder to detect than the circumferential one. Additionally, the defect is only 0.5 mm deep; therefore, it is the worst case (hardest to detect). The examined defect is close to the detection limit of the system as the defect signal is significantly lower in comparison to other cases. Therefore, the observed background signal can influence the ability of the system and affect the performance at a much higher rate. As a result, when only few sensors are used during inspection of a given part, even a slight decrease of SNR can be obtained. Thus, only when more than 4 sensors are used to scan the given angular range of the sample can the monotonic rise in the SNR be noticed.
In the procedure of performance evaluation of data fusion schemes, additional aspects can be considered. The application of data fusion allows one to simultaneously balance the operation of the system in reference to the factors related to inspection area range and coverage of a single sensor, reliability of results, and acquisition time. Due to the limitations in the scope of the scanning speed increment (at higher scanning speed, the eddy current could strongly affect the results), the multisensor array could be utilized simultaneously for decreasing the scanning speed for minimization of the eddy current effect and preserving the inspection time at least at a similar duration level. Another aspect is the dimensions of defects that might occur in the material, which the system should be able to indicate. Then, the scanning resolution should be at least similar to those dimensions. In this paper, the sampling frequency could be adjusted within the range of 40–400 Hz. The inspection time contains two periods: first, the scanning combined with data acquisition, and the period for resetting a new linear position. Taking into consideration the defect dimensions on the surface of the examined sample (5 mm length and around 0.5 mm width), the inspection time, when using all 8 sensors to perform the 45° scan (resulting in angular rotation range of 45°), could be increased from around 4 times for the highest sampling frequency to around 7 times for the lowest one in comparison to a 360° scan.
In order to validate the information content enhanced by the applied fusion rules, an additional experiment was carried out. The aim was to assess the ability of the obtained results to correctly indicate the occurrence of defects. As it was described earlier, the defects’ orientation with respect to the direction of the magnetizing field plays an important role in the proper defect characterization process. Therefore, an automatic procedure for validation of defect orientation was introduced (Figure 18).
The diagram of the procedure is presented in Figure 18d. The process was based on the fused results of Stage II obtained for the DFPYR rule. First, the statistical analysis was processed and the thresholding procedure was applied. The threshold was adjusted to the mean value of part of the signal for which the level was higher than its 3rd quartile. As a result, the 2-D distribution was obtained, depicting the indicated defected area DA. Next, principal component analysis (PCA) was carried out for the achieved spatial distribution of points in the (l, α) space, allowing one to define two axes of main variation of the DA: PC1 and PC2. In consequence, the length of the sections defining the dimensions in both main directions were obtained. In order to determine the final length of data variability in the samples axial and circumferential directions, the PC1 and PC2 sections were projected into the l and α axes of the sample. The achieved orientation evaluation results are presented in Table 3. One can notice that in each case, the longer dimension of the defect was properly indicated. The longer dimension in the axial direction was evaluated for defects d1, d3, and d5 (axial defects), and in the circumferential direction for defects d2, d4, and d6 (axial defects). However, it must be pointed that the proposed procedure can be used only for the orientation indication of the longer dimension of defects, as the achieved evaluated values differ largely from the real one.
Further, taking into consideration the obtained grouping results, the changes in defect signal amplitude were analyzed for both orientations. The results of the ratio of fused results of components x and y (Stage I) are presented in Figure 19. It can be noticed that there is clearly visible change of the ratio with the growing depth of the defects. Depending on the direction of the defect, the increase in depth causes an increase in the amplitude of a particular component of the vector of field leakage sensed by the array. Therefore, in the case of circumferential defects, the ratio is decreasing and in axial ones, it is growing. Nevertheless, the obtained data confirmed the possibility to utilize the fused results in further processes of precise characterization of defect dimensions.

7. Conclusions

In this paper, a multisensor array was utilized to perform data fusion procedures under various measuring conditions, allowing adjusting systems in terms of reliability and inspection time. The study was carried out considering inspection data of defects in a circular-shaped tube sample. During data collection, the vector magnetic leakage field over the area where the defects occurred in the examined steel object was monitored. The observation was carried out for defects with different depths and orientations in reference to the direction of the magnetizing field. The experiments were conducted for various sensor configurations. Next, multisensor data registration was carried out in order to transfer all data into a common space. Then, four multisource signal fusions were introduced and applied for all modes of sensor array configurations. Finally, the quality of the obtained results was assessed. For that need, the entropy and signal-to-noise ratio were computed for all utilized sensor configuration strategies. Next, in order to validate the information content of the data achieved during the fusion process, an additional experiment was carried out to assess the defect indication capability.
It was shown that the application of data fusion rules for a magnetic multisensor inspection system can result in a growth in reliability of the proper identification and classification of defects in steel elements. In accordance with the system operation objective demanded by the end user, a different data fusion algorithm could be implemented. Each sensor in the array defines its own set of data. When considering the character of the repose signal caused by the defect, a common representation can be built by calculation of cumulative magnetic vector lengths. Such an approach was carried out using the DFvec algorithm. The other way to build a conjunctive representation, allowing preservation in the fused result of all data supplied by each sensor, the addition operation of set contents can be carried out. Frequently, this methodology is updated with weighting factors corresponding to each set’s importance (in terms of final set definition). In such a case, referred to as the “compromise” representation, the addition operation can be supplemented with the weights calculated on the basis of the coefficients describing the data. In this paper, for this purpose, the DFSF algorithm was used. It allows one to simultaneously build a representation of all sensors’ full data in the final result, and also to reward and penalize the sources in terms their data quality level. On the other hand, it must be pointed that both useful information (concerning the defected area) and background signals are transferred into the resulting distribution under this method. Therefore, considering achieving a higher confidence level in the indication of the defect area, the DFIOP algorithm was applied. It validates in the final result only the part of the data which is common for all input sources. Thus, the random background signal level is much reduced. On the other hand, even a small error in the registration process can also affect the signal distribution in the defect area. High efficiency in noise reduction when building a compromise representation can be also achieved by the application of multiresolution analysis methodology (DFPYR algorithm). It allows one to transform the input data into a series of low or bandpass representations at different frequency bands. Thus, both the low-frequency background signal and the high-frequency noise can be significantly reduced. In the same time, the defected area signal representation remains practically unchanged. The subjective and objective assessment of the fusion results confirmed higher performance of the multisensor system in comparison to single-source data. The signal fusion scheme can be relatively easily applied in industrial measuring systems. Simultaneous use of algorithms DFIOP and DFPYR can significantly affect the increment of levels of correct indication of the defects. Nevertheless, the obtained results showed that the configuration of multisensor systems should be deeply considered in accordance with multiple aspects.

Funding

The APC was co-funded by Research Funds of Faculty of Electrical Engineering of West Pomeranian University of Technology, Szczecin and Szczecin Branch of The Polish Society for Non-destructive Testing and Technical Diagnostics of the Polish Society of Mechanical Engineers and Technicians SIMP (PTBNiDT SIMP).

Acknowledgments

The author would like to express his gratitude to Professor Tomasz Chady from West Pomeranian University of Technology, Szczecin for the possibility of cooperation, and later support and motivation to work on the subject.

Conflicts of Interest

The author declares no conflict of interest. The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.

References

  1. Shi, Y.; Zhang, C.; Li, R.; Cai, M.; Jia, G. Theory and Application of Magnetic Flux Leakage Pipeline Detection. Sensors 2015, 15, 31036–31055. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Wang, R.; Kawamura, Y. An Automated Sensing System for Steel Bridge Inspection Using GMR Sensor Array and Magnetic Wheels of Climbing Robot. J. Sens. 2016, 2016, 15. [Google Scholar] [CrossRef] [Green Version]
  3. Le, M.; Lee, J.; Jun, J.; Kim, J.; Moh, S.; Shin, K. Hall sensor array based validation of estimation of crack size in metals using magnetic dipole models. NDT E Int. 2013, 53, 18–25. [Google Scholar] [CrossRef]
  4. Wu, J.; Fang, H.; Huang, X.; Xia, H.; Kang, Y.; Tang, C. An Online MFL Sensing Method for Steel Pipe Based on the Magnetic Guiding Effect. Sensors 2017, 17, 2911. [Google Scholar] [CrossRef] [PubMed]
  5. Tian, J.; Gao, M.; He, Y. Oil Tube Defect Detection Based on Multi-sensor Data Fusion with Self-adaptive Genetic Fuzzy Neural Network. J. Comput. Inf. Syst. 2013, 9, 1891–1898. [Google Scholar]
  6. Usarek, Z.; Warnke, K. Inspection of gas pipelines using magnetic flux leakage technology. Adv. Mater. Sci. 2017, 17, 37–45. [Google Scholar] [CrossRef]
  7. Carvalho, A.A.; Rebello, J.M.A.; Sagrilo, L.V.S.; Camerini, C.S.; Miranda, I.V.J. MFL signals and artificial neural networks applied to detection and classification of pipe weld defects. NDT E Int. 2006, 36, 661–667. [Google Scholar] [CrossRef]
  8. Singh, W.S.; Rao, P.B.C.; Thirunavukkarasu, S.; Mahadevan, S.; Mukhopadhyay, C.K.; Jayakumar, T. Development of magnetic flux leakage technique for examination of steam generator tubes of prototype fast breeder reactor. Ann. Nucl. Eng. 2015, 83, 57–64. [Google Scholar] [CrossRef]
  9. Gao, Y.; Tian, G.Y.; Li, K.; Ji, J.; Wang, P.; Wang, H. Multiple cracks detection and visualization using magnetic flux leakage and eddy current pulsed thermography. Sen. Actuators A Phys. 2015, 234, 269–281. [Google Scholar] [CrossRef]
  10. Liu, X.C.; Wang, Y.J.; Wu, B.; Gao, Z.; He, C.F. Design of Tunnel Magnetoresistive-Based Circular MFL Sensor Array for the Detection of Flaws in Steel Wire Rope. J. Sens. 2016, 2016, 8. [Google Scholar] [CrossRef]
  11. Singh, W.S.; Rao, P.B.C.; Thirunavukkarasu, S.; Jayakumar, T. Flexible GMR Sensor Array for Magnetic Flux Leakage Testing of Steel Track Ropes. J. Sens. 2012, 2012, 6. [Google Scholar] [CrossRef]
  12. Le, M.; Kim, J.; Yang, D.; Lee, H.; Lee, J. Electromagnetic testing of a welding area using a magnetic sensor array. Int. J. Appl. Electromagn. Mech. 2017, 55, 119–124. [Google Scholar] [CrossRef]
  13. Lopato, P.; Psuj, G.; Herbko, M.; Maciusowicz, M. Evaluation of stress in steel structures using electromagnetic methods based on utilization of microstrip antenna sensor and monitoring of AC magnetization process. Inf. Contr. Meas. Econ. Env. Prot. IAPGOS 2016, 6, 32–36. [Google Scholar] [CrossRef]
  14. Szymanik, B.; Psuj, G.; Lopato, P.; Maciusowicz, M.; Herbko, M. Multimodal fatigue progress monitoring of construction steel elements. In Proceedings of the Quantitative InfraRed Thermography Conference (QIRT), Gdansk, Poland, 4–8 July 2016; pp. 297–305. [Google Scholar] [CrossRef]
  15. Babbar, V.; Clapham, L. Residual Magnetic Flux Leakage: A Possible Tool for Studying Pipeline Defects. J. Nondestr. Eval. 2003, 22, 117–125. [Google Scholar] [CrossRef] [Green Version]
  16. Deng, Z.; Sun, Y.; Kang, Y.; Song, K.; Wang, R. A Permeability-Measuring Magnetic Flux Leakage Method for Inner Surface Crack in Thick-Walled Steel Pipe. J Nondestr. Eval. 2017, 36, 68. [Google Scholar] [CrossRef]
  17. Franco, F.; Cardoso, F.A.; Rosado, L.S.; Ferreira, R.; Cardoso, S.; Piedade, M.; Freitas, P.P. Advanced NDT inspection tools for titanium surface based on high-performance magnetoresistive sensors. IEEE Trans. Magn. 2017, 53, 1–5. [Google Scholar] [CrossRef]
  18. Li, Y.; Wilson, J.; Tian, G.Y. Experiment and simulation study of 3D magnetic field sensing for magnetic flux leakage defect characterization. NDT E Int. 2007, 40, 179–184. [Google Scholar] [CrossRef]
  19. Chady, T.; Psuj, G.; Kowalczyk, J.; Spychalski, I. Electromagnetic system for nondestructive evaluation of train hollow axles. In Proceedings of the 2013 Far East Forum on Nondestructive Evaluation/Testing: New Technology and Application (FENDT), Jinan, China, 17–20 June 2013; pp. 29–34. [Google Scholar] [CrossRef]
  20. Martyna, R.; Martyna, M. Polish technology for testing wire ropes of the largest rope devices in the world. Bad. Nieniszcz. Diag. 2017, 3, 11–16. [Google Scholar] [CrossRef]
  21. Costain, J.; Pearson, N.R.; Boat, M.A.; Boba, R. Capability of modern tank floor scanning with Magnetic Flux Leakage. Bad. Nieniszcz. Diag. 2017, 3, 20–23. [Google Scholar] [CrossRef]
  22. Psuj, G. Magnetic field multi-sensor transducer for detection of defects in steel components. IEEE Trans. Magn. 2017, 53, 1–4. [Google Scholar] [CrossRef]
  23. Psuj, G. Multi-Sensor Data Integration Using Deep Learning for Characterization of Defects in Steel Elements. Sensors 2018, 18, 292. [Google Scholar] [CrossRef] [PubMed]
  24. Chady, T.; Psuj, G. Data Fusion From Multidirectional Remanent Flux Leakage Transducers for Nondestructive Testing of Stress- and Fatigue-Loaded Steel Samples. IEEE Trans. Magn. 2008, 44, 3285–3288. [Google Scholar] [CrossRef]
  25. Lo, C.C.H. Characterization of residual stress in ferrous components by magnetic anisotropy measurements using a hall effect sensor array probe. AIP Conf. Proc. 2011, 1335, 1249–1255. [Google Scholar] [CrossRef]
  26. Psuj, G. Data Fusion of Matrix Transducer’s Signals for Evaluation of Train Hollow Axles. In Proceedings of the International Symposium on Theoretical Electrical Engineering, Pilsen, Czech Republic, 24–26 June 2013; pp. III-17–III-18. [Google Scholar]
  27. Elmenreich, W. An Introduction to Sensor Fusion; Research report; Vienna University of Technology: Vienna, Austria, 2002. [Google Scholar]
  28. Weckenmann, A.; Jiang, X.; Sommer, K.-D.; Neuschaefer-Rube, U.; Seewig, J.; Shaw, L.; Estler, T. Multisensor data fusion in dimensional metrology. CIRP Ann. 2009, 58, 701–721. [Google Scholar] [CrossRef]
  29. Abdelgawad, A.; Bayoumi, M. Data Fusion in WSN. In Resource-Aware Data Fusion Algorithms for Wireless Sensor Networks; Springer: New York, NY, USA, 2012; pp. 17–35. [Google Scholar]
  30. Su, Z.; Ye, L. Algorithms for Damage Identification—Fusion of Signal Features. In Identification of Damage Using Lamb Waves. From Fundamentals to Applications; Springer-Verlag: London, UK, 2009; Volume 48, pp. 195–254. [Google Scholar]
  31. Durrant-Whyte, H.F. Sensor Models and Multisensor Integration. Int. J. Rob. Res. 1988, 7, 97–113. [Google Scholar] [CrossRef]
  32. Raol, J.R. Data Fusion Mathematics: Theory and Practice; CRC Press: Boca Raton, FL, USA, 2016. [Google Scholar]
  33. Lewis, J.J.; O’Callaghan, R.J.; Nikolov, S.G.; Bull, D.R.; Canagarajah, N. Pixel- and region-based image fusion with complex wavelets. Inf. Fusion 2007, 8, 119–130. [Google Scholar] [CrossRef]
  34. Naidu, V.P.S.; Raol, J.R. Pixel-level Image Fusion using Wavelets and Principal Components Analysis. Defence Sci. J. 2008, 58, 338–352. [Google Scholar] [CrossRef]
  35. Li, S.; Kang, X.; Fang, L.; Hu, J.; Yin, H. Pixel-level image fusion: A survey of the state of the art. Inf. Fusion 2017, 33, 100–112. [Google Scholar] [CrossRef]
  36. Khaleghi, B.; Khamis, A.; Karray, F.O.; Razavi, S.N. Multisensor data fusion: A review of the state-of-the-art. Inf. Fusion 2013, 14, 28–44. [Google Scholar] [CrossRef]
  37. Li, S.; Yang, B. Multifocus image fusion using region segmentation and spatial frequency. Image Vision Comput. 2008, 26, 971–979. [Google Scholar] [CrossRef]
  38. Li, S.; Li, Z.; Gong, J. Multivariate statistical analysis of measures for assessing the quality of image fusion. Int. J. Image Data Fusion 2010, 1, 47–66. [Google Scholar] [CrossRef]
  39. Liu, Z.; Wu, W. Fusion with Infrared Images for an Improved Performance and Perception. In Pattern Recognition, Machine Intelligence and Biometrics; Springer: Berlin/Heidelberg, Germany, 2011. [Google Scholar]
  40. Ghassemian, H. A review of remote sensing image fusion methods. Inf. Fusion 2016, 32, 75–89. [Google Scholar] [CrossRef]
Figure 1. Visualization of multisensor array arrangement inside a steel sample with depicted circumferential α and axial l directions: cross sections in (a) circumferential A-A and (b) axial B-B planes of the sensor array; (c) cross section in the axial plane of two types of examined defects.
Figure 1. Visualization of multisensor array arrangement inside a steel sample with depicted circumferential α and axial l directions: cross sections in (a) circumferential A-A and (b) axial B-B planes of the sensor array; (c) cross section in the axial plane of two types of examined defects.
Sensors 18 02091 g001
Figure 2. Visualization of magnetic leakage vectors over axial (a) and circumferential (b) types of defect with depicted scanning circumferential α and axial l directions and sensing x, y, and z directions.
Figure 2. Visualization of magnetic leakage vectors over axial (a) and circumferential (b) types of defect with depicted scanning circumferential α and axial l directions and sensing x, y, and z directions.
Sensors 18 02091 g002
Figure 3. Presentation of implementation of various multisensor data fusion strategies: (a) competitive; (b) complementary; and (c) cooperative data.
Figure 3. Presentation of implementation of various multisensor data fusion strategies: (a) competitive; (b) complementary; and (c) cooperative data.
Sensors 18 02091 g003
Figure 4. The general overview of the successive stages of the defect evaluation process.
Figure 4. The general overview of the successive stages of the defect evaluation process.
Sensors 18 02091 g004
Figure 5. Distributions of Vx, Vy, and Vz, and norm Vn values of vector field sensed by selected single sensor (s3) obtained for (a) the 2 mm depth axial defect (d5) and (b) the 0.5 mm depth circumferential defect (d4) over 2-D scanning area (l, α); unit: 100 equals 0.4 G.
Figure 5. Distributions of Vx, Vy, and Vz, and norm Vn values of vector field sensed by selected single sensor (s3) obtained for (a) the 2 mm depth axial defect (d5) and (b) the 0.5 mm depth circumferential defect (d4) over 2-D scanning area (l, α); unit: 100 equals 0.4 G.
Sensors 18 02091 g005
Figure 6. The block diagram of the data registration process.
Figure 6. The block diagram of the data registration process.
Sensors 18 02091 g006
Figure 7. Spatial alignment evaluation of the transducer’s sensors: (a) view of the sensor array with depicted angular distances Δϕ between two successive sensors,; (b) results of the angular misalignment δϕ estimation; (c) visualization of linear misalignment δl estimation as a difference between center locations in linear positions of given sensor si, i = 1, 2, 3, 4, 6, 7, 8, and the sensor s5, and (d) results of the sensor linear misalignment δl estimation.
Figure 7. Spatial alignment evaluation of the transducer’s sensors: (a) view of the sensor array with depicted angular distances Δϕ between two successive sensors,; (b) results of the angular misalignment δϕ estimation; (c) visualization of linear misalignment δl estimation as a difference between center locations in linear positions of given sensor si, i = 1, 2, 3, 4, 6, 7, 8, and the sensor s5, and (d) results of the sensor linear misalignment δl estimation.
Sensors 18 02091 g007
Figure 8. Distributions of field Vn and vn norm sensed by successive sensors obtained for 0.5 mm depth circumferential defect (d4) over 2-D scanning area (l, α): (a) before and (b) after the registration process; unit: 100 equals 0.4 G.
Figure 8. Distributions of field Vn and vn norm sensed by successive sensors obtained for 0.5 mm depth circumferential defect (d4) over 2-D scanning area (l, α): (a) before and (b) after the registration process; unit: 100 equals 0.4 G.
Sensors 18 02091 g008
Figure 9. Distributions of registered vx, vy, and vz, and norm vn values of vector field sensed by a selected single sensor (s3) obtained for (a) a 2 mm depth axial defect (d5) and (b) a 0.5 mm depth circumferential one (d4) over 2-D scanning area (l, α); unit: 100 equals to 0.4 G.
Figure 9. Distributions of registered vx, vy, and vz, and norm vn values of vector field sensed by a selected single sensor (s3) obtained for (a) a 2 mm depth axial defect (d5) and (b) a 0.5 mm depth circumferential one (d4) over 2-D scanning area (l, α); unit: 100 equals to 0.4 G.
Sensors 18 02091 g009
Figure 10. Distributions of field Vn norm sensed by successive sensors obtained for a 0.5 mm depth circumferential defect (d4) over 2-D scanning area (l, α) for an angular range of each sensor equal to (a) 45° and (b) 90°; unit: 100 equals to 0.4 G.
Figure 10. Distributions of field Vn norm sensed by successive sensors obtained for a 0.5 mm depth circumferential defect (d4) over 2-D scanning area (l, α) for an angular range of each sensor equal to (a) 45° and (b) 90°; unit: 100 equals to 0.4 G.
Sensors 18 02091 g010
Figure 11. Block diagram of the general data fusion scheme.
Figure 11. Block diagram of the general data fusion scheme.
Sensors 18 02091 g011
Figure 12. Block diagram of the data fusion process: Stage I.
Figure 12. Block diagram of the data fusion process: Stage I.
Sensors 18 02091 g012
Figure 13. A visualization of exemplary results of successive levels of Laplacian pyramid decomposition obtained for vx of a selected sensor.
Figure 13. A visualization of exemplary results of successive levels of Laplacian pyramid decomposition obtained for vx of a selected sensor.
Sensors 18 02091 g013
Figure 14. Results of Stages I (vxdf, vydf and vzdf) and II (vndf) of data fusion obtained for axial defect d5 with 2 mm depth using (a) DFvec; (b) DFSF; (c) DFIOP; and (d) DFPYR algorithms; and for a circumferential defect d4 with 0.5 mm depth using (e) DFvec; (f) DFSF; (g) DFIOP; and (h) DFPYR algorithms.
Figure 14. Results of Stages I (vxdf, vydf and vzdf) and II (vndf) of data fusion obtained for axial defect d5 with 2 mm depth using (a) DFvec; (b) DFSF; (c) DFIOP; and (d) DFPYR algorithms; and for a circumferential defect d4 with 0.5 mm depth using (e) DFvec; (f) DFSF; (g) DFIOP; and (h) DFPYR algorithms.
Sensors 18 02091 g014
Figure 15. Results of Stage II (vndf) of data fusion obtained for successive defects: 1 mm depth axial d1 (a) and circumferential d2 (b); 0.5 mm depth axial d3 (c) and circumferential d4 (d); and 2 mm depth axial d5 (e) and circumferential d6 (f).
Figure 15. Results of Stage II (vndf) of data fusion obtained for successive defects: 1 mm depth axial d1 (a) and circumferential d2 (b); 0.5 mm depth axial d3 (c) and circumferential d4 (d); and 2 mm depth axial d5 (e) and circumferential d6 (f).
Sensors 18 02091 g015
Figure 16. Results of Stage II (vndf) of data fusion obtained for the 0.5 mm circumferential d4 defect achieved for angular range of each sensor equal to 45° and using algorithms (a) DFvec; (b) DFSF; and (c) DFPYR; and for angular range equal to 90° and using algorithms (d) DFvec; (e) DFSF; (f) DFIOP, and (g) DFPYR.
Figure 16. Results of Stage II (vndf) of data fusion obtained for the 0.5 mm circumferential d4 defect achieved for angular range of each sensor equal to 45° and using algorithms (a) DFvec; (b) DFSF; and (c) DFPYR; and for angular range equal to 90° and using algorithms (d) DFvec; (e) DFSF; (f) DFIOP, and (g) DFPYR.
Sensors 18 02091 g016
Figure 17. Changes of SNR and E coefficient levels in response to the increase of the angular measuring range of a single sensor from 45° (complementary data) to 360° (redundant data): computed for DFPYR (a) and DFIOP (b).
Figure 17. Changes of SNR and E coefficient levels in response to the increase of the angular measuring range of a single sensor from 45° (complementary data) to 360° (redundant data): computed for DFPYR (a) and DFIOP (b).
Sensors 18 02091 g017
Figure 18. Results of successive stages of final defect identification procedure: fused results (a); zoomed defect area (b); indication of evaluated defect area together with the two main axes of area variation (c); block diagram of the successive steps of the defect orientation procedure (d).
Figure 18. Results of successive stages of final defect identification procedure: fused results (a); zoomed defect area (b); indication of evaluated defect area together with the two main axes of area variation (c); block diagram of the successive steps of the defect orientation procedure (d).
Sensors 18 02091 g018
Figure 19. Results of defect depth evaluation based on the ratio of vxdf and vydf.
Figure 19. Results of defect depth evaluation based on the ratio of vxdf and vydf.
Sensors 18 02091 g019
Table 1. Evaluation of data fusion scheme based on entropy E.
Table 1. Evaluation of data fusion scheme based on entropy E.
NameEntropy
d1d2d3d4d5d6
Raw Signal6.986.357.346.816.076.19
DFvec6.986.287.386.776.246.14
DFSF7.006.277.426.846.266.15
DFIOP1.360.171.730.290.090.20
DFPYR6.225.116.755.375.385.25
Table 2. Evaluation of data fusion scheme based on SNR.
Table 2. Evaluation of data fusion scheme based on SNR.
NameSignal-to-Noise Ratio (SNR) (dB)
d1d2d3d4d5d6
Raw Signal8.8910.666.5410.3715.0910.97
DFvec9.0911.446.7811.5414.8511.82
DFSF8.8310.446.3110.6014.0611.50
DFIOP45.7958.9444.4656.6264.9159.10
DFPYR14.7021.9411.6620.3019.9622.19
Table 3. Evaluation of inspected defect orientation.
Table 3. Evaluation of inspected defect orientation.
DefectEstimated Dimension in α Direction (mm)Estimated Dimension in l Direction (mm)Real Dimensions in α Direction (mm)Real Dimensions in l Direction (mm)
d11.121.430.55
d22.781.6650.5
d32.554.360.55
d43.941.5650.5
d51.852.490.55
d64.642.3050.5

Share and Cite

MDPI and ACS Style

Psuj, G. Utilization of Multisensor Data Fusion for Magnetic Nondestructive Evaluation of Defects in Steel Elements under Various Operation Strategies. Sensors 2018, 18, 2091. https://doi.org/10.3390/s18072091

AMA Style

Psuj G. Utilization of Multisensor Data Fusion for Magnetic Nondestructive Evaluation of Defects in Steel Elements under Various Operation Strategies. Sensors. 2018; 18(7):2091. https://doi.org/10.3390/s18072091

Chicago/Turabian Style

Psuj, Grzegorz. 2018. "Utilization of Multisensor Data Fusion for Magnetic Nondestructive Evaluation of Defects in Steel Elements under Various Operation Strategies" Sensors 18, no. 7: 2091. https://doi.org/10.3390/s18072091

APA Style

Psuj, G. (2018). Utilization of Multisensor Data Fusion for Magnetic Nondestructive Evaluation of Defects in Steel Elements under Various Operation Strategies. Sensors, 18(7), 2091. https://doi.org/10.3390/s18072091

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop