Next Article in Journal
Robust Adaptive HCS MPPT Algorithm-Based Wind Generation System Using Model Reference Adaptive Control
Next Article in Special Issue
Reducing Unspecific Protein Adsorption in Microfluidic Papers Using Fiber-Attached Polymer Hydrogels
Previous Article in Journal
CIDF-WSN: A Collaborative Interest and Data Forwarding Strategy for Named Data Wireless Sensor Networks
Previous Article in Special Issue
Silver-Assembled Silica Nanoparticles in Lateral Flow Immunoassay for Visual Inspection of Prostate-Specific Antigen
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives

Department of Chemistry, University of Torino, 10125 Torino, Italy
*
Author to whom correspondence should be addressed.
Sensors 2021, 21(15), 5185; https://doi.org/10.3390/s21155185
Submission received: 6 June 2021 / Revised: 27 July 2021 / Accepted: 28 July 2021 / Published: 30 July 2021
(This article belongs to the Special Issue Lateral Flow Immunoassay: Advances and Applications)

Abstract

:
The Lateral Flow Immunoassay (LFIA) is by far one of the most successful analytical platforms to perform the on-site detection of target substances. LFIA can be considered as a sort of lab-in-a-hand and, together with other point-of-need tests, has represented a paradigm shift from sample-to-lab to lab-to-sample aiming to improve decision making and turnaround time. The features of LFIAs made them a very attractive tool in clinical diagnostic where they can improve patient care by enabling more prompt diagnosis and treatment decisions. The rapidity, simplicity, relative cost-effectiveness, and the possibility to be used by nonskilled personnel contributed to the wide acceptance of LFIAs. As a consequence, from the detection of molecules, organisms, and (bio)markers for clinical purposes, the LFIA application has been rapidly extended to other fields, including food and feed safety, veterinary medicine, environmental control, and many others. This review aims to provide readers with a 10-years overview of applications, outlining the trends for the main application fields and the relative compounded annual growth rates. Moreover, future perspectives and challenges are discussed.

1. Introduction

Conventional laboratory-based analytical methods like high-performance liquid chromatography (HPLC), gas chromatography (GC), mass spectrometry (MS), enzyme-linked immunosorbent assay (ELISA) and real time polymerase chain reaction (qPCR) usually require complex and long procedures to obtain a result [1,2,3], but several situations often require a fast and on-site analyte detection [4,5]. As a consequence, in the last decades, the scientific research has been focused more and more on the development and optimization of portable, affordable, and user-friendly rapid methods of analysis for point-of-need (PON) testing [6,7,8].
Immunochemical bioanalytical methods represent one of the most versatile strategies for point-of-need applications thanks to their ability to give highly specific and sensitive results [9]. It is not by chance that most screening and rapid methods are based on immunoassays. An immunoassay is a biochemical test that is commonly used to measure the concentration of target molecules. This method is based on the reaction of an analyte/antigen (Ag) with a selective antibody (Ab) forming an Ab–Ag complex. The efficacy of immunoassay is mainly based on the efficiency of Ab–Ag complex formation and on the ability to detect the rate of complex formation.
Among the different immunoassay-based analytical platforms, the lateral flow immunoassay technique (LFIA), also known as immunochromatographic strip test (ICST), or rapid diagnostic test (RDT), has become one of the most successful analytical platforms for decentralized or point-of-need testing strategy requiring little to no supporting infrastructure. The LFIA is a paper-based (bio)analytical technique for the on-site detection of target substances, where the sample is added on a standalone device and the result is obtained in a few minutes. LFIAs satisfied all the criteria of an ideal POCT that is required to be “ASSURED” (Affordable, Sensitive, Specific, User-friendly, Rapid and robust, Equipment-free, and Delivered) [10]. Initially referred to diagnostic tests for sexually transmitted infections, the ASSURED criteria have become the benchmark for any point of care tests (POCT) and more in general for any point of need tests.
The LFIAs success can be also noticed also considering their position in the commercial landscape. In fact, in the 2019 the global market for lateral flow tests was estimated at about US $5.98 billion and it is projected to reach US $10.36 billion by 2027, growing at a compounded annual growth rate (CAGR) of 7.7% from 2020 to 2027 [11].
Thanks to their advantages of simplicity, rapidity, cost-effectiveness and no requirement of equipment or technical expertise, the LFIAs are very useful especially in low-resource field environments and in developing countries that cannot afford standard instrumentation to perform analyses. However, they are widely used also in developed countries with the aim of increasing the number of analyses, reaching high-throughput goals and rapid decision-making in several fields, while mitigating costs. For example, in 2019, North America and Europe dominated the global lateral flow assay market holding the majority shares [11].
The LFIA can be considered as a sort of lab-in-a-hand and together with other PON tests has represented a paradigm shift from sample-to-lab to lab-to-sample aiming to improve decision making and turnaround time [4]. The very attractive features of LFIA have driven to reach a wide acceptance and appeal of this technique (the main LFIA features are reported in Figure 1). Therefore, from the detection of hormones, parasites, bacteria, cells, viruses, biological markers for clinical purposes, the LFIA application has been rapidly extended to other fields, including food and feed safety, veterinary medicine, environmental control, forensic analysis, and many others [12,13,14].
Even if much innovation has been devoted towards the LFIA sensitivity enhancement [15,16,17], most of the developed LFIA have more than adequate sensitivity for the detection of the most different analytes. Usually, both for the competitive and the non-competitive format, the LFIA limit of detections are between 0.1 and 10 ng mL−1 and very rarely they fall below 0.1 ng mL−1 [4,14,17]. The adequate analytical sensitivity, together with versatility and good usability, made LFIA the most commercially available POC diagnostic format [13]. This is also due to the fact that in contrast to other promising paper-based analytical platforms that mainly remain as laboratory prototypes, LFIA devices easily enter into real-life applications with a high market penetration mainly because they do not need extensive upgrades to become an end-user device [18]. The wide acceptance of LFIA devices also played an eminent role in the use of the platform for the detection of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), in the current pandemic situation, as we can still notice and as extensively reported in the literature [19,20,21,22,23,24,25,26,27,28].
Previous reviews about LFIA have provided an overview on specific topics such as the use of particular labels [29], or the use of particular molecular recognition element [30,31], sensitivity enhancement and instrumental detection methods [15,16,17], multiplex approach [32,33], and general improvements [34].
The aim of this review is to analyse the lateral flow assay applications state-of-the-art within the 2010–2019 period, providing the respective trends. The year 2020 has not been included because some articles may be not yet indexed in the database. Moreover, the year 2020 could be a source of bias for the trend of clinical application field, due to plenty of publications related to the detection of the SARS-CoV-2. Nonetheless, some considerations regarding the potential opportunities for LFIA devices arose from the pandemic situation will be provided, together with an overview of the most recent and hot applications for each relevant field (not fully comprehensive) mainly covering the 2020–2021 time frame.
In more details, in the following sections the general principles and the fundamental components of LFIAs are briefly introduced. Then, we introduce the literature review methodology and the most relevant LFIA application fields, i.e., clinical, food safety, veterinary, environmental, and others, underlying the LFIA benefits in the respective fields. Subsequently, we report the trends and the CAGR for the main application fields, considering the multiplexing aspect as well. We also discuss what we think is essential to foster an increasing implementation of LFIAs, focusing on the critical challenges to be addressed. Finally, our perceptions regarding the future development of LFIA devices is provided.

2. General Principles and the Fundamental Components of LFIAs

The general structure of the LFIA is reported in Figure 2 and consists of an ensemble of components providing chemical, physical, and mechanical features [35,36,37,38,39,40].
Basically, it appears as a multilayer strip [14]. On a backing plastic support (Figure 2a), a thin layer of porous nitrocellulose membrane (Figure 2b) adheres. The backing support acts as a platform for the assembling of the different components of the test and confers physical rigidity to the device. At the ends, two cellulose or glass fiber pads are pasted—the sample pad and the absorbent pad (Figure 2c,d) [14]. The sample pad absorbs gradually the liquid sample and makes a physical pre-treatment reducing the matrix effects. The absorbent pad works as the driving force for the capillary flow and a sink for the liquid processed through the strip. Between the sample pad and the beginning of the nitrocellulose membrane is stuck another pad, generally made of polyester or glass fiber, called conjugate pad (Figure 2e). On defined regions (generally lines) of the nitrocellulose, solutions containing immunoreagents are dispensed (Figure 2f,g). These can be one or more specific areas called Test lines and one Control line. The role of the Test lines is to give evidence of the interaction with the target molecule(s) and, consequently, the required information. The Control line ensures the correct functioning of the test by binding with the probe independently on the presence of the target. The conjugate pad is impregnated with a suitable labelled immunoreagent solution (usually gold nanoparticles- or latex-labelled antibodies [4,35,37,38,39,40]) and dried (Figure 2h). The assembled strip is enclosed and stored into a plastic cassette (Figure 2i,j) providing a window in the area that includes the reactive regions on the nitrocellulose (reading window, Figure 2k). Another hole is in correspondence of the sample pad, upon which the sample will be introduced (sample well, Figure 2l). The cassette provides some pressure points allowing the contact between the overlapped components, assuring the correct flow of the sample/labelled conjugate mix solution along the whole strip (Figure 2m–o) [39].
The LFIA starts by applying the liquid sample on the sample pad (Figure 3). The solution resuspends the labelled immunoreagents from the conjugate pad and the analytes and the labelled probe flow by capillary forces along the membrane and through the lines, where immunoreactions take place [14]. Usually, they do not require external reagents for completing the assay besides the liquid sample. Results are quick and easy to interpret, usually without the help of equipment for qualitative assays [4]. In addition, as discussed in Section 7, “Evergreen and new challenges”, the use of reader devices allows to obtain also semiquantitative results, avoiding the subjective results interpretation.

3. Literature Review Methodology

The Scopus database was used to search English articles (no review) between 2010 and 2019. The search query consisted of terms considered adequate by the authors to review the literature on the LFIA applications. Because the authors would give to the readers a clear and wide scenario on the LFIA uses, no limitations regarding the field of application were included in the initial research. To simplify the research, the most common nomenclature (lateral flow immunoassay) was searched in title, abstract and keywords, while other nomenclatures referred to the technique were searched just in the article titles. The search query used was (Scopus format): TITLE-ABS-KEY (lateral AND flow AND immunoassay) OR TITLE (lateral AND flow AND assay) OR TITLE (immunochromatographic) AND PUBYEAR > 2009 AND PUBYEAR < 2020 AND (LIMIT-TO (DOCTYPE, “ar”)) AND (LIMIT-TO (LANGUAGE, “English”)). The research has been done in October 2020. Then, the articles were selected following the PRISMA guideline for systematic reviews [41].
A total of 2165 document results were obtained and screened to assess their inclusion in the present review. Therefore, 2165 articles title and abstract were examined to remove publications that were not relevant. Eighty-seven articles were excluded because they were not related to the LFIA topic; thus, 2078 articles were identified as relevant. Subsequently, the articles were initially classified in the following classes: clinical, food safety, technical improvement/novelty, veterinary, environmental, agriculture, industrial, forensic, and other. While most of these classes are self-explained, we want to point out the meaning of some of them. Publications in which the application was just a proof-of-concept or a model system to demonstrate advances in the technique were classified as “technical improvement/novelty”. Publications regarding plant diseases were classified as “agriculture”. Publications regarding the quality control of industrial processes were classified as “industrial”. The output of this classification process is reported in Figure 4.

4. Applications

4.1. Clinical Applications

Currently, clinical diagnostic tests often rely on analyses performed in a central laboratory giving results after several hours or even days [4,8,42]. Considering that in many cases a timely decision can drastically affect the clinical outcome, the potential benefits of LFIA use in the clinical field are self-evident [4,8,42]. LFIA can make a valuable contribution in screening, help in diagnosis, prognosis, monitoring, and surveillance [4]. The immediate clinical assessment may have a tremendous impact in the disease management reducing the workload, enhancing the workflow, improving clinical care and patients’ outcomes, and potentially decreasing costs [4,42]. The use of LFIAs can allow patients to receive the diagnosis and the specific treatment during the same consultation, reducing the number of clinical visits avoiding referral and problems related to delay in starting the therapy [42]. Moreover, long-term benefits should not be underestimated. For example, LFIA can help distinguishing between bacterial and viral infections, thus identifying cases where antibiotics therapy is needed, limiting the misuse of these drugs that lead to accelerate the antibiotic resistance.
LFIAs have the inherently suitability for use outside the laboratory setting [42]. Therefore, in addition to those performed by healthcare professionals in hospital laboratories, LFIAs are used in hospital wards, clinics, health centers, physicians’ offices, and even patients’ home in the self-testing format [4,36,42]. It is undeniable that the most emblematic test in the clinical field is the pregnancy test [7,36]. However, many others LFIAs have been developed and used over time for different clinical purposes [4].
The great success of LFIAs in the clinical field can be associated with the direct impact on the human health and also because the very first applications have had clinical purposes. Moreover, it is worth noting that, even considering the relative complexity of biological fluids, they are quite limited in number. For example, the most used biological matrices are venous or capillary blood, saliva, urine, nasopharyngeal swabs, and stools [4,18,40]. Therefore, once defined, a suitable sample treatment the analysis becomes quite easy. Sample handling and/or treatment can include multiple variations depending on the sample type, including plasma separation from fingerstick or venous whole blood, filtration, cellular lysis for bacteria or viral intracellular antigens, and breakup of mucins in saliva or respiratory samples or changes in pH of urine, to name a few examples [43]. In some cases, these kinds of treatments can be performed using particular sample pads, therefore without additional steps [4]. Moreover, the recognition elements usually employed in LFIA (antibodies) are inherently inclined to perform very well in biological fluids.
In the considered 10-year period, the detection of infectious diseases accounted for 69% of the total applications (50% bacterial, 36% viral, and 14% caused by other organisms), followed by the detection of endogenous markers and biomarkers (28%), while the remaining 3% mainly comprises the detection of drugs and their monitoring. It is not surprising that the vast majority of applications are for infectious diseases since the rapid and early identification of an infected person allows limiting the infection spread itself and increases the probability of patients’ recovery. Other driving forces that boosted the application in the infectious diseases field are the willingness and the efforts of the World Health Organization (WHO) to face the so-called priority/key diseases. In fact, this trend also reflects the LFIAs reported in the list of essential in vitro diagnostic (EDL) issued in 2018, and last-updated in 2019, by the WHO. The EDL outlines a group of IVDs that are recommended by WHO for use at various levels of a tiered national health care system with the aim of providing evidence-based guidance and serving as reference to Members States who are developing and/or updating lists of national essential IVDs for defining universal health coverage interventions, as well as selecting and implementing such IVDs [44]. The EDL mainly comprises the detection of infectious diseases like cholera, cryptococcal meningitis (in people with advanced HIV disease), dengue virus, hepatitis B and C, HIV, influenza A and B, malaria, syphilis, tuberculosis, and visceral leishmaniasis [45]. In addition to these LFIAs application, in the EDL are also listed the pregnancy testing, and the detection of C-reactive protein and procalcitonin. Considering that the EDL will be expanded and updated annually promoting progress towards the goal of universal health coverage, it can be expected that several new applications will be added in the near future.

4.2. Food Safety Applications

The production and the commercialization of food that does not cause a risk to the consumer is a major global concern because it is known that unsafe food can cause over 200 diseases that can range from digestive tract infection to cancer. Moreover, every year 420,000 people die and more than 600 million fall ill from eating contaminated food [46]. To reduce these frightful numbers, the food safety must be guaranteed along the whole food chain in order to avoid the presence of potentially toxic substances such as veterinary drugs, heavy metals, pesticides, toxins, fertilizers, pathogens and undeclared allergenic ingredients [1,13,47]. Following good agricultural and good manufacturing practices is the cornerstone to pursue this goal [48]. However, only a widespread network of controls can further minimize the risk [2,47,49].
The use of LFIAs in food safety can help the management of foodborne risks by increasing the number of analyses, making them accessible, fast, and inexpensive, allowing to monitor food safety alongside production chain, from raw materials to ready-to-eat products. Moreover, their simple and fast use makes them the ideal device to be implemented in the Hazard Analysis and Critical Control Points (HACCP) procedures [49].
Compared to LFIAs devoted to the clinical diagnostic field that have to deal with limited sample matrices, LFIAs for food safety have to tackle an additional challenge due to food matrices that can be as diverse as complex and numerous [40,47]. To have an idea of such a diversity, we can just think of how it can be different to analyse cereals, biscuits, meat, spices, milk, alcoholic and non-alcoholic beverages, drinking water, etc. Accordingly, the needs of every new device become very different. For example, monitoring of mycotoxins in food and feed may requires very different approaches along the entire production chain, and in all these scenarios, the LFIA should be robust and adaptable enough to ensure a valid analysis [47,50]. Based on the properties of the target analyte and the related matrix, sometimes it can be necessary to use an organic solvent to perform the extraction. However, antibodies and LFIA components (especially the nitrocellulose membrane) have a restricted tolerance for organic solvents. Therefore, a challenging task in assay development may be determining an optimal solvent system for both analyte solubility and method performance. Sometimes an additional dilution step in a proper buffer is essential to provide a suitable medium to allow more efficient analyte detection.
In the considered 10-year period, the most frequent application in this field was the detection of toxins (39%), followed by drugs (30%, mainly antibiotics), and pathogens (22%), while pesticides, adulterants, and allergens accounted for the remaining 9%.

4.3. Veterinary Applications

Veterinary medicine mainly applies to companion animals like dogs, cats, etc., and to livestock animals, i.e., animals that are considered as an asset (cows, sheep, poultry, pigs, etc.). Veterinary services are essential to assure animal health and, in a broader context, to prevent and control animal diseases, including those transmissible to humans (zoonoses), to ensure the sanitary safety of world trade in terrestrial and aquatic animals and animal products, and to improve animal welfare worldwide [51]. Veterinary medicine shares several similarities with clinical diagnostic for human health. Even in this field, a timely right decision can drastically affect the outcome.
Effective surveillance, early detection, transparency, and rapid response mechanisms in the event of disease outbreaks are the key to prevent and control animal diseases. Controlling the diseases that affect terrestrial and aquatic animals and improving the welfare of these animals are the core of the World Organisation for Animal Health (OIE, historic acronym of the Office International des Epizooties) mandate [52], not only because it has obvious health benefits for both animals and humans, but also considering the impact on the sustainability of socio-economic and ecological systems.
Nowadays, animal diseases can spread even more because of the exponential growth in trade and tourism. The official sanitary status of countries regarding animal diseases has become a key factor to preserve animal health, public health, and a safe international trade. The 182 OIE member countries undertake to report the terrestrial and aquatic animal health situation in their territory in a timely and transparent manner. The disease identification and the outbreak report must be as fast as possible to minimize their negative impacts. Of course, the most worrisome diseases are the infectious ones due to the easiness of spread and to their dramatic consequences (large-scale culling of livestock in some cases). In this context, the use of rapid screening tests may help and accelerate the infectious disease identification and thus direct immediate and focused actions to stem its spread. Moreover, considering that 60% of the pathogens that affect humans are of animal origin [51,53], it is easy to understand the crucial role of the early detection of these diseases at their source in animals.
The use of diagnostic rapid tests in the veterinary field has increased in the last decades due to the willingness of pet owners to keep their pets healthy, and to the increased acceptance from farmers of the benefits of near-animal testing [54]. The ability to provide an immediate answer leads to better management and intervention strategies. Currently, veterinarians use rapid tests to screen commercial livestock and household pets for several medical conditions. These tests have potential utility in many veterinary settings, including private clinics, academic veterinary medical centres, the community in remote area, and for research applications in academia, government, and industry [55].
Another driving force for the increasing acceptance of diagnostic rapid tests in veterinary medicine is the increasing concern of customers about antibiotics and transmissible diseases in milk, eggs and meat, and to the widespread public concern over the spread of diseases through populations of animals [54]. Some of these concerns are strictly related to food safety and human health and they are added to the global concern regarding antimicrobial resistance that causes food production losses, poor animal welfare and extra costs.
In many countries, providing antimicrobials in the feed and water of farmed animals to prevent disease or to stop its spread accounts for a greater proportion of total antimicrobial use in farming than the treatment of sick animals [56]. Such practices often occur without precise diagnosis and without confirmed disease presence.
In the World Health Assembly held in May 2015, it appeared clear that the antimicrobial resistance crisis needed to be managed with the utmost urgency. Consequently, in the same year, the WHO launched a global action plan on antimicrobial resistance, which outlines five strategic objectives [57]. Among these objectives, the focus was on optimizing the use of antimicrobial medicines in human and animal health and on increasing the investment in diagnostic tools. It was pointed out that effective, rapid, low-cost diagnostic tools were needed for guiding optimal use of antibiotics in human and animal medicine, and that such tools should be integrated into clinical, pharmacy and veterinary practices. Ensuring that rapid and affordable point-of-care tests are available for critical animal diseases where antimicrobials are most commonly used will reduce the misuse of these drugs in animal treatment improving antimicrobial stewardship and animal health and welfare [58]. On this basis, reliable LFIAs can help veterinarians and farmers to make a responsible and prudent use of antimicrobial agents, thus maintaining their therapeutic efficacy.
Considering the huge variety of animal species and their related peculiarities, LFIAs for veterinary use have to deal with a multitude of matrices like serum, urine, buccal and nasal secretions, mammary secretions, milk, faeces, respiratory exhalations, etc.
As imaginable, in the considered 10-years period, the detection of infectious diseases accounted for 93% of the total LFIA applications (51% viral, 27% bacterial, and 22% caused by other organisms), followed by the detection of drugs.

4.4. Environmental Applications

The environmental pollution has become a global crucial issue. Several pollutants and contaminants enter the environment either because of anthropogenic activities like industry, agriculture, transport, everyday life, etc., or through naturally occurring event [59,60]. Pollutants and contaminants can be air-, soil-, or waterborne, and may move from one medium to other (for example, soil to water). They can directly and indirectly affect human health, and the socio-economic development of a country [61]. Therefore, a major concern lies in detecting and monitoring air, soil, and water pollutants [62].
The environmental monitoring is the essential and regulated activity that aims at safeguarding the environment and protecting living beings from exposure to toxic pollutants, contamination sources, and pathogens. This monitoring can be divided in three macrophases: (i) initial monitoring that is required to identify the levels and effects of certain pollutants on the environmental media; (ii) identification of the sources of these pollutants in order to effectively inform the policymakers; (iii) continued monitoring of environmental conditions that is important to verify if environmental quality standards are fulfilled (verify for concentrations in water, sediment and biota that must not be exceeded) and to assess the usefulness of the regulatory actions, once implemented [63].
The pollutants monitoring allows identifying the spatial distribution of contaminants to determine which sites are at risk and examine temporal trends at different sites to determine if the situation is improving or worsening [64]. This process generally provides data on average concentrations in environmental media, while peak concentrations are obtained when the measurement is performed at the waste point.
The control of contaminant levels in the environment is costly, often time-consuming, and labour-intensive, especially considering the largeness of the environmental media. The accomplishment of environmental analyses requires a great deal of advanced analytical chemistry expertise, together with complex and expensive instrumentations [60]. In fact, chromatographic and spectroscopic methods are used in the laboratory for detection of pollutants, and polymerase chain reaction (PCR) based detection is usually used for identification of pathogens [62]. Therefore, alternative approaches that can provide on-site, high-throughput, easy, and real-time testing in a speedy manner are highly demanded to perform a cost-effective monitoring [65].
LFIAs can be used as environmental quality monitoring tools in the assessment of inorganic and organic pollutants, and biological contaminants [40]. While this kind of sensors are not usually used for monitoring air quality, they are mainly used for monitoring water- and soilborne contaminants [40,62]. In this context, contaminants detection in soil involves extraction procedures, while water samples usually need minimal pre-treatment. Nevertheless, improvement in the analytical performances (mainly the sensitivity) are a big challenge for the use of LFIAs because the permissible levels set by regulatory agencies can be very low for some substances [66].
In the considered 10-year period, the detection of heavy metals has been the prevalent application (37%), followed by pesticides (14%), algae (11%), pathogens (10%), toxins (8%), drugs (6%) and other compounds (14%).
Unlike the previous application fields in which one target class (or two for food safety) accounts for ca. 70% of the total applications (or even ca. 90% for veterinary), target classes in environmental application are more assorted. This can be explained considering that, historically, several substances have been worried about the ecosystem. In fact, heavy metals, pesticides, pathogens, and toxins—that all together account for ca. 70% of total applications—have been considered as some of the most worrisome environmental pollutants, led by heavy metals mainly due to industrial wastewater [67].
Moreover, in the last few years, the concept of emerging contaminants (ECs) has become more and more pressing, and consequently more and more substance classes needed to be monitored to safeguard the environment. ECs include a wide range of chemicals, such as persistent organic pollutants, pharmaceuticals, personal care products, endocrine disrupting compounds, sweeteners, nanoparticles, etc. [68,69]. Among ECs, antimicrobials have become an increasing concern, due to the increasing likelihood that microbials develop resistance against drugs and can accumulate in wildlife. As stated in previous sections, antimicrobials resistance is a global concern; in this context, the One Health action plan was launched, in 2017, by the European Commission as part of the WHO’s global One Health program that recognizes the interconnectedness of human health, animal health, and the environment for sources of resistant bacteria [70]. Monitoring the environment for antimicrobial resistant species is also crucial because it might help to predict clinically relevant infection outbreaks [71].

4.5. Other Applications

The previous applications accounted for more than 90% of LFIA total applications. Nevertheless, LFIA is also applied in other fields. In the considered 10-years period, the remaining applications are dominated by the use in the agriculture field (40%) where LFIAs mainly help in the detection of plant diseases, followed by the quality monitoring of industrial products and/or processes (22%) and by applications in the forensic field (22%) like detection of blood and illegal substances. Finally, niche applications have been also reported in the literature from cultural heritage to biotechnology [72,73]. Among them, the detection of biohazard compounds is extremely relevant. In fact, some of the compounds mentioned in the previous sections like bacteria, viruses, fungi, and toxins that threat the human health may be used in biowarfare attack; therefore, their prompt detection can make the difference in the effectively contrast of bioterrorism.

5. Multiplex LFIAs

The simultaneous analysis of more than one analyte in a single test, i.e., the multiplex detection, is increasing its relevance in several fields. The capability of multiplexing can significantly improve the efficiency of testing and reduce costs while enhancing high-throughput detection. It is strongly requested for those applications in which advanced decision-making is needed or availability of samples is limited [32].
Multiplex testing has become more and more requested in contemporary clinical diagnoses [12]. With the increasing numbers of (bio)markers discovered, there is often a need to detect several (bio)markers simultaneously to generate meaningful or conclusive information, especially when a single (bio)marker may be indicative of more than one cause or when a particular condition is influenced by more than one parameter. In addition to this, due to the increased number of compounds to be monitored, the possibility to obtain information regarding all the involved targets within the same single test has become highly demanded in food safety, veterinary, and environmental monitoring as well.
The simultaneous detection of multiple analytes is mainly realized using the design of several Test lines in a single strip allowing the targets discrimination through the spatial resolution [30,32,74,75,76]. Combining multiple lines is the most direct way of increasing the detection capability while retaining the merits of single LFIA systems. This approach has been mostly used in the detection of food borne bacterial pathogens and mycotoxins but has also been described for the detection of single nucleotide polymorphisms, parasites, and antibodies [30]. The evaluation of a test with several Test lines may be not so user-friendly; therefore, integrated reader system can represent a useful, but more expensive solution, reducing their potential use in low-resource environment. However, misleading interpretation can be avoided using multicolour labels, simplifying the visual interpretation without compromising the cost-effectiveness of the test.
In addition to the spatial resolution strategy, the separation of reaction sites using single strips for each specific target, arranged in a multichannel structure, has also been exploited [77,78,79]. In this alternative strategy, no risk of reciprocal interference exists between assays. However, the sample volume required increases with the increase of strips number arrayed together, as well as the fabrication costs and reagents consumption.
Recently, the use of a single strip with a single Test line has also been applied for multiplexed detection of target molecules, exploiting surface-enhanced Raman scattering [80,81] and colorimetric detection [82,83]. Moreover, most recently, Cavalera et al. proposed a two-parameter multiplexing LFIA strategy (x2LFIA), which combines the spatial resolution with colour encoding approach to expand the number of information achievable within a single strip test, obtaining tetravalent information in a two-line and two-colour assay [84].
The trends for the multiplex LFIAs, in the considered 10-year period, are reported in the following section.

6. LFIA Applications Trends

Interestingly, in the 10-year period, the food safety application showed the highest growth with a CAGR of 21%, while clinical application grew at a CAGR of 16%, followed by veterinary (13%) and environmental (9%). Clinical application most likely will reach and overcome again the growth of food application in 2020–2021 due to the COVID-19 pandemic and the related LFIA developed to detect the viral antigens or the antibodies against them. In the same period, the efforts of researchers to enhance the LFIA technique can be highlighted from the 18% CAGR of articles publication regarding technical improvements.
Excluding the articles mainly focused on the technical improvements (298) and unifying in the category “other” the applications related to agriculture, industrial, forensic and other (e.g., biotechnology, cultural heritage, etc.), the breakdown by LFIA application is reported in Figure 5a. As expected, in the considered 10-year period, the clinical application accounted for the majority of the total LFIA applications (almost half), followed by food safety, veterinary and environmental.
Another interesting trend can be drawn for the applications in which two or more target analytes are detected simultaneously (multiplex analysis). The multiplex analysis grew at a CAGR of 26% and the breakdown by field of application is reported in Figure 5b. Clinical and food safety applications share equally almost the totality of the multiplex segment. This breakdown can be explained remembering the essential role of multianalyte detection in clinical diagnostic and considering all the advantages derived from detecting in a single analysis all the compounds to be monitored in the same food sample.
The great significance that the scientific community is giving to the multiplex analysis can be evaluated also by monitoring the impressive CAGR in clinical (37%) and food safety (57%) fields.
In order to provide an overview of the most recent and hot applications, in Table 1, Table 2, Table 3, Table 4 and Table 5 we also reported some of the most interesting examples of LFIA for each relevant field mainly covering the 2020–2021 time frame.

7. Evergreen and New Challenges

Although LFIAs are inherently the ideal qualitative screening method, they have been asked to be a quantitative method that allows the analyte ultrasensitive detection. A lot of efforts have been made in this direction thanks to the use of new labels and/or strategies to improve the sensitivity, and to the use of dedicated strip readers [15,16,17,34,267].
The employment of more or less sophisticated external readers allowed the quantitative analysis of LFIA strips by measuring the intensities of the signals generated at the reactive lines. While on the one hand the use of readers increases the cost per analysis, on the other it allows data digitalization, tracking, storage, and transmission reducing interpretation and transcription errors, thus ensuring testing quality and control [18]. In this sense, we are also witnessing an increasing exploitation of the built-in smartphone technology to be used as LFIA reader, as increasingly reported in the literature [122,132,267,268,269,270,271,272,273,274,275]. Moreover, the use of strip readers paved the way for the use of alternative detection methods (fluorescence, chemiluminescence, etc.) allowing better performances and quantitative measurements. In fact, the colorimetric detection has dropped from 93.7% in 2010 to 78.1% in 2019 mainly in favour of the fluorescence (from 3.8% to 15.8%) and surface-enhanced Raman spectroscopy (SERS) detection (from 0% to 3.6%). However, as can be observed from the breakdown by detection methods reported in Figure 6, in the period from 2010 to 2019 the colorimetric detection still dominates (82.5%), followed by fluorescence (12.3%) and SERS (1.8%) detection.
As additional information, analyzing the breakdown by LFIA colorimetric labels employed in the considered period (Figure 7), the gold nanoparticles accounted for the 88.4% followed by latex (2.6%) and carbon nanoparticles (2.1%). Most recently, the use of gold nanoparticles has slightly decreased (from 89% in 2010, to 81% in 2019) mainly in favor of the use of composite nanoparticles that has grown from 0% to 6%.
Despite the several advantages resulting from the use of LFIAs, there are still some concerns regarding the routine use of these devices. For example, some veterinarians expressed discontent about the increasing use of LFIAs by farmers themselves without veterinary supervision [56]. These concerns are mainly due to the risks associated with such role diversification (somehow also related to the professional authority delegitimization when tests are being used directly by the end-user) and diagnostic simplification including samples contamination, poor control of the environment, misinterpretation of the results and, as a potential consequence, unnecessary or inappropriate drugs use. However, the concerns regarding the correct use of the device can be addressed through (i) unambiguous instructions sheet, (ii) training of the end-user, (iii) limiting the number of steps to be performed, (iv) meticulous design development, and (v) performing accurate test usability. On the other hand, as previously mentioned, the possible misinterpretation of the results can be solved using reader devices.
Another great concern regards the reliability of tests, their diagnostic power and accuracy compared with laboratory test procedures, concern that is shared also by some general practitioners that consider this aspect, together with clinical management, as the most important aspect for implementation in routine use [276]. Reliable qualitative and/or quantitative results can only be achieved by means of a deep validation of the LFIA device and meticulous quality control. This aspect has been underestimated in most publications regarding the development and application of new LFIAs. While one might think that this aspect should only concern manufacturers, it is undeniable that the researchers’ community can be a fundamental and ground-breaking support to draw up or to test validation protocols as shown by the interesting and pioneering studies of Lattanzio et al. [277,278,279,280,281] and by a few other researchers [282,283]. In this regard, very recently, Bheemavarapu et al. proposed a promising tool for the quality assessment of LFIA strips batches and to assure a robust validation of the test itself through an image processing-based algorithms to evaluate sample flow abnormalities or membrane irregularities [284].
An increasing use of LFIAs to obtain quantitative and reliable results will only be possible if the highest standards of quality and performance will be met. In this regard, the effective implementation of LFIA, in routine use, can be boosted through national and international regulations that have the aim of guaranteeing the safety, quality, and effectiveness of in vitro diagnostic tests.
Nevertheless, sometimes the impact of new regulations can have a negative effect on the use of diagnostic tests, especially at the beginning of their implementation. For example, in 1988, there was the introduction of the Clinical Laboratory Improvement Amendments (CLIA) regulations that include federal standards applicable to all U.S. facilities or sites that test human specimens for health assessment or to diagnose, prevent, or treat disease. A few years after the CLIA regulations entered into force, it has been reported that more than 64% of physicians cited CLIA 1988 as a factor in their decision to reduce or eliminate in-office testing. The most striking effect of CLIA 1988 appeared to be on pediatric practices and practices in rural areas, of which more than 70% have reduced or eliminated onsite testing, thus sending patients and specimens to outside facilities, compromising patient’s access to timely quality testing, resulting in delays in diagnosis and treatment [285]. However, after an initial negative effect, the in-office testing thrived again driven by the physicians’ belief in the POCT utility, by the economic interest and by the fact that hundreds of tests have been approved for the waived category.
Moving to the present day, a radical improvement is expected to be obtained in the next years thanks to the new European Regulation on in vitro diagnostic medical devices that establishes more restrictive requirements for IVDs quality, safety, and reliability [286] whereby most of the self-certified IVDs will have to be re-certified through the conformity assessment by a notified body. Therefore, clinicians and end users will no longer have to rely only on the good faith of the manufacturers, but they will also have the assurance that the device has been approved by a third party. Of course, the same care should be applied also to the other fields of applications.

8. Future Perspectives

We have already outlined the importance of multiplex LFIAs in several application fields. The number of multiplexing LFIAs is expected to grow exponentially because they improve the efficiency of testing and because more and more diagnostic questions require the detection of various analytes to explain a particular condition. However, the multiplexing strategies applied up to now have inherent limitations regarding the maximum number of analytes to be detected simultaneously. A possible solution might be the use of the microarray format that owns the right peculiarities to improve the multiplex capability. Although very promising, this approach has been reported just a few times in the literature [2,287,288,289,290] and the reason of this under-use may be mainly associated to the possible microfluidic modification in using a microarray pattern on the membrane instead of the lines pattern, and to the more complex readability of the results that may cause misleading results interpretation. A deeper and more accurate study of the microarray LFIA and the use of a reading device could help its spread in the near future.
It has already been outlined that LFIAs own all the features to satisfy the ASSURED criteria. Recently, these criteria have been revised by adding three criteria, namely, real-time connectivity, ease of specimen collection, and environmental friendliness to assemble the so-called REASSURED criteria [239]. Unsurprisingly LFIA can already meet almost all of these additional desiderata.
Regarding the real-time connectivity, the use of smartphones as strips reader (as previously mentioned) or hand-held readers equipped with a connectivity module allow to deal with this task in an easy way.
The specimen collection is usually very simple; moreover, the following sample preparation does not require multiple steps, apart from cases where a dilution or extraction must be done. However, in most cases, solutions transfer and manual mixing are enough to prepare the sample for the analysis. Because specimen collection and treatment are the basis to perform an accurate analysis, the easiest standardized protocol should be provided to the end user in order to minimize operations and user errors. In this regard, innovations and improvements are still highly required in order to provide cartridges for sample preparation that could be integrated or connected directly to the strip.
In comparison to other analytical techniques, LFIA can be considered as a green and environmentally friendly technique both because most of the devices do not use organic solvent (except for the extraction of some analytes from solid sample) and because the sample can be analysed minimizing ancillary costs, for example minimizing the energy consumption, avoiding sample transportation and the need for the cold chain, etc. However, being a disposable device, the use of plastic cassettes is an issue for the environment and therefore the use of recycled plastic is highly desirable. The use of biodegradable components could also be desirable, even if most of the LFIAs for professional use (in the clinical field) must be incinerated due to possible biohazard. Notwithstanding the exceptional properties of the nitrocellulose as solid support for the LFIA platform, researchers [291,292,293] are trying to replace its use with the cellulose that, in addition to further reducing costs, would have a reduced impact on the environment because its production process requires less chemicals in comparison to the nitrocellulose production. Most recently, promising results have been obtained by Adrian Elter et al. that developed cellulose-based LFIAs [294]. However, their strategy consists in the use of carbohydrate binding module-fused antibodies and therefore it cannot be directly applied using currently available antibodies without additional steps.
The unprecedented pressure on laboratories and health care systems, due to the COVID-19 pandemic, caused the postponement of almost all medical examinations, screening, and diagnostic tests not related to the COVID-19 spread. As a consequence, the need of decentralized rapid diagnostic tests has been highlighted now more than ever because they can be regarded as useful allies to help in diagnosis without increasing the workload. However, they also have to deal with the recent discontent originated from their use to detect antibodies against SARS-CoV-2 or to detect the virus itself, and with the negative publicity received from media and people’s opinion. This situation was mainly due because (i) the serological detection of antibodies against SARS-CoV-2 was used to diagnose the infection and to perform retrospective epidemiological analysis, and (ii) the first antigenic LFIAs had poor sensitivity, resulting unreliable [295,296,297,298,299].
Although the recent outbreak may be a great opportunity for the durable implementation of LFIAs to loosen the testing pressure on health care facilities, it has also highlighted how the effective use of rapid tests may occur only guaranteeing their reliability (certifying, though a deep validation, the test accuracy, precision, sensitivity, specificity, etc.), and their meditated and cautious use. The ease of use must not compromise analytical performances, otherwise all the benefits deriving from the use of the LFIAs would be lost, especially if they are used for the wrong purpose.

9. Conclusions

After about half a century from its first development, the LFIA technique is increasingly used thanks to its global scalability and to its features that allow reducing costs and workload, while enhancing the workflow efficiency improving the turnaround time. LFIAs have become one of the reference point-of-need tests to obtain results in a timely manner without the need of high-sophisticated and high-cost laboratory equipment, in clinical, food safety, veterinary, and environmental testing.
The interest of the scientific community for the LFIA is still very high, as can be noted by the increasing number of research papers aiming to improve one or more aspects of the technique. The sensitivity enhancement and the quantitative output have been the most studied features during the last decades. Nevertheless, the colorimetric detection is still the most widely used detection method, and gold nanoparticles still dominate the colorimetric labels scenario.
Most recently, the environmental friendliness has become a leading topic also stimulated by the introduction of the REASSURED criteria, as a revised and extended version of the ASSURED criteria coined to describe the ideal POCT to be used in the developing world, and then became the gold standard features for any point-of-need test. Likewise, the easy specimen collection and treatment should dictate the next advances and improvements in LFIA.
In the period from 2010 to 2019, multiplex LFIAs showed the highest CAGR and are expected to continue to grow due to their unquestionable benefits. The main field of application is confirmed as the clinical one. However, it is worth noting that, in the same period, the number of publications regarding the LFIA use related to the food safety field has grown with a CAGR higher than the clinical field. However, this trend is expected to be overturned in 2020–2021 considering the plenty of publications about the use of LFIA related to SARS-CoV-2.
The global outbreak of SARS-CoV-2 itself may be a boost to the LFIAs routine use both in poorly supplied structures in order to allow the decentralization of primary care and the simplification of the diagnostic process, and even in highly advanced and organized facilities that own sophisticated instrumentations. At the same time, an increasing trust in the LFIAs use in the clinical field will continue to foster more and more their use also in other fields.
However, a massive use is only possible guaranteeing the reliability of the LFIA devices and of any kind of advancement related to the device itself. In this regard, an accurate validation is essential to obtain reliable rapid tests that can be really helpful, establishing more and more as the right tool to answer, in timely manner, the right question.

Funding

This work was supported by the Ministry of Education, University and Research of Italy (PRIN: 2017Y2PAB8).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The datasets generated and/or analyzed during the current study (Figure 4, Figure 5, Figure 6 and Figure 7) are available from the corresponding author on reasonable request.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Choi, J.R.; Yong, K.W.; Choi, J.Y.; Cowie, A.C. Emerging Point-of-care Technologies for Food Safety Analysis. Sensors 2019, 19, 817. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Charlermroj, R.; Phuengwas, S.; Makornwattana, M.; Sooksimuang, T.; Sahasithiwat, S.; Panchan, W.; Sukbangnop, W.; Elliott, C.T.; Karoonuthaisiri, N. Development of a microarray lateral flow strip test using a luminescent organic compound for multiplex detection of five mycotoxins. Talanta 2021, 233, 122540. [Google Scholar] [CrossRef] [PubMed]
  3. Campbell, V.R.; Carson, M.S.; Lao, A.; Maran, K.; Yang, E.J.; Kamei, D.T. Point-of-Need Diagnostics for Foodborne Pathogen Screening. SLAS Technol. 2020, 26, 55–79. [Google Scholar]
  4. Soh, J.H.; Chan, H.-M.; Ying, J.Y. Strategies for developing sensitive and specific nanoparticle-based lateral flow assays as point-of-care diagnostic device. Nano Today 2020, 30, 100831. [Google Scholar] [CrossRef]
  5. Hansen, S.; Abd El Wahed, A. Point-Of-Care or Point-Of-Need Diagnostic Tests: Time to Change Outbreak Investigation and Pathogen Detection. Trop. Med. Infect. Dis. 2020, 5, 151. [Google Scholar] [CrossRef]
  6. Makarona, E.; Petrou, P.; Kakabakos, S.; Misiakos, K.; Raptis, I. Point-of-Need bioanalytics based on planar optical interferometry. Biotechnol. Adv. 2016, 34, 209–233. [Google Scholar] [CrossRef] [PubMed]
  7. Weihs, F.; Anderson, A.; Trowell, S.; Caron, K. Resonance Energy Transfer-Based Biosensors for Point-of-Need Diagnosis—Progress and Perspectives. Sensors 2021, 21, 660. [Google Scholar] [CrossRef]
  8. Parolo, C.; Merkoçi, A. Paper-based nanobiosensors for diagnostics. Chem. Soc. Rev. 2013, 42, 450–457. [Google Scholar] [CrossRef]
  9. Van Emon, J.M. Immunoassay and Other Bioanalytical Techniques, 1st ed.; CRC Press, Taylor and Francis Group: Boca Raton, FL, USA, 2007. [Google Scholar]
  10. Kettler, H.; White, K.; Hawkes, S.J.; UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases. Mapping the Landscape of Diagnostics for Sexually Transmitted Infections: Key Findings and Recommendations. 2004. Available online: https://apps.who.int/iris/handle/10665/68990 (accessed on 17 May 2021).
  11. Global Lateral Flow Assay Market Size by Type, by Technique, by Application, by End-user, by Geography and Forecast. Available online: https://www.verifiedmarketresearch.com/product/lateral-flow-assay-market/ (accessed on 17 May 2021).
  12. Li, J.; Macdonald, J. Multiplexed lateral flow biosensors: Technological advances for radically improving point-of-care diagnoses. Biosens. Bioelectron. 2016, 83, 177–192. [Google Scholar] [CrossRef]
  13. Eltzov, E.; Guttel, S.; Kei, A.L.Y.; Sinawang, P.D.; Ionescu, R.E.; Marks, R.S. Lateral Flow Immunoassays—From Paper Strip to Smartphone Technology. Electroanalysis 2015, 27, 2116–2130. [Google Scholar] [CrossRef]
  14. Bahadır, E.B.; Sezgintürk, M.K. Lateral flow assays: Principles, designs and labels. TrAC-Trend. Anal. Chem. 2016, 82, 286–306. [Google Scholar] [CrossRef]
  15. Mak, W.C.; Beni, V.; Turner, A.P.F. Lateral-flow technology: From visual to instrumental. Trends Anal. Chem. 2016, 79, 297–305. [Google Scholar] [CrossRef]
  16. Bishop, J.D.; Hsieh, H.V.; Gasperino, J.D.J.; Weigl, B.H. Sensitivity enhancement in lateral flow assays: A systems perspective. Lab Chip 2019, 19, 2486–2499. [Google Scholar] [CrossRef] [Green Version]
  17. Nguyen, V.; Song, S.; Park, S.; Joo, C. Recent advances in high-sensitivity detection methods for paper-based lateral-low assay. Biosens. Bioelectron. 2020, 152, 112015. [Google Scholar] [CrossRef] [PubMed]
  18. Yamada, K.; Shibata, H.; Suzuki, K.; Citterio, D. Toward practical application of paper-based microfluidics for medical diagnostics: State-of-the-art and challenges. Lab. Chip. 2017, 17, 1206. [Google Scholar] [CrossRef] [PubMed]
  19. Espejo, A.P.; Akgun, Y.; Al Mana, A.F.; Tjendra, Y.; Millan, N.C.; Gomez-Fernandez, C.; Cray, C. Review of Current Advances in Serologic Testing for COVID-19. Am. J. Clin. Pathol. 2020, 154, 293–304. [Google Scholar] [CrossRef] [PubMed]
  20. Ruhan, A.; Wang, H.; Wang, W.; Tan, W. Summary of the Detection Kits for SARS-CoV-2 Approved by the National Medical Products Administration of China and Their Application for Diagnosis of COVID-19. Virol. Sin. 2020, 35, 699–712. [Google Scholar]
  21. Zhu, N.; Woong, P.K. Advances in Viral Diagnostic Technologies for Combating COVID-19 and Future Pandemics. SLAS Technol. 2020, 25, 513–521. [Google Scholar] [CrossRef] [PubMed]
  22. Deeks, J.J.; Dinnes, J.; Takwoingi, Y.; Davenport, C.; Spijker, R.; Taylor-Phillips, S.; Adriano, A.; Beese, S.; Dretzke, J.; Ferrante di Ruffano, L.; et al. Cochrane COVID-19 Diagnostic Test Accuracy Group. Antibody tests for identification of current and past infection with SARS-CoV-2. Cochrane Database Syst. Rev. 2020, 6, CD013652. [Google Scholar]
  23. Dinnes, J.; Deeks, J.J.; Adriano, A.; Berhane, S.; Davenport, C.; Dittrich, S.; Emperador, D.; Takwoingi, Y.; Cunningham, J.; Beese, S.; et al. Cochrane COVID-19 Diagnostic Test Accuracy Group. Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection. Cochrane Database Syst. Rev. 2020, 8, CD013705. [Google Scholar]
  24. Vashist, S.K. In Vitro Diagnostic Assays for COVID-19: Recent Advances and Emerging Trends. Diagnostics 2020, 10, 202. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. Mekonnen, D.; Mengist, H.M.; Derbie, A.; Nibret, E.; Munshea, A.; He, H.; Li, B.; Jin, T. Diagnostic accuracy of serological tests and kinetics of severe acute respiratory syndrome coronavirus 2 antibody: A systematic review and meta-analysis. Rev. Med. Virol. 2020, 31, e2181. [Google Scholar] [CrossRef]
  26. Kailasa, S.K.; Mehta, V.N.; Koduru, J.R.; Basu, H.; Singhal, R.K.; Murthy, Z.V.P.; Park, T.-J. An overview of molecular biology and nanotechnology based analytical methods for the detection of SARS-CoV-2: Promising biotools for the rapid diagnosis of COVID-19. Analyst 2021, 146, 1489–1513. [Google Scholar] [CrossRef]
  27. Antiochia, R. Paper-Based Biosensors: Frontiers in Point-of-Care Detection of COVID-19 Disease. Biosensors 2021, 11, 110. [Google Scholar] [CrossRef]
  28. Ernst, E.; Wolfe, P.; Stahura, C.; Edwards, K.A. Technical considerations to development of serological tests for SARS-CoV-2. Talanta 2021, 224, 121883. [Google Scholar] [CrossRef]
  29. Huang, Y.; Xu, T.; Wang, W.; Wen, Y.; Li, K.; Qian, L.; Zhang, X.; Liu, G. Lateral flow biosensors based on the use of micro- and nanomaterials: A review on recent developments. Microchim. Acta 2020, 187, 70. [Google Scholar] [CrossRef]
  30. Jauset-Rubio, M.; El-Shahawi, M.S.; Bashammakh, A.S.; Alyoubi, A.O.; O’Sullivan, C. Advances in aptamers-based lateral flow assays. Trends Anal. Chem. 2017, 97, 385–398. [Google Scholar] [CrossRef]
  31. Reid, R.; Chatterjee, B.; Das, S.J.; Ghosh, S.; Sharma, T.K. Application of aptamers as molecular recognition elements in lateral flow assays. Anal. Biochem. 2020, 593, 113574. [Google Scholar] [CrossRef]
  32. Anfossi, L.; Di Nardo, F.; Cavalera, S.; Giovannoli, C.; Baggiani, C. Multiplex Lateral Flow Immunoassay: An Overview of Strategies towards High-throughput Point-of-Need Testing. Biosensors 2019, 9, 2. [Google Scholar] [CrossRef] [Green Version]
  33. Huang, L.; Tian, S.; Zhao, W.; Liu, K.; Ma, X.; Guo, J. Multiplexed detection of biomarkers in lateral-flow immunoassays. Analyst 2020, 145, 2828–2840. [Google Scholar] [CrossRef]
  34. Mahmoudi, T.; de la Guardia, M.; Shirdel, B.; Mokhtarzadeh, A.; Baradan, B. Recent advancements in structural improvements of lateral flow assays towards point-of-care testing. Trends Anal. Chem. 2019, 116, 13–30. [Google Scholar] [CrossRef]
  35. Anfossi, L.; Di Nardo, F.; Cavalera, S.; Giovannoli, C.; Spano, G.; Speranskaya, E.S.; Goryacheva, I.Y.; Baggiani, C. A lateral flow immunoassay for straightforward determination of fumonisin mycotoxins based on the quenching of the fluorescence of CdSe/ZnS quantum dots by gold and silver nanoparticles. Microchim. Acta 2018, 185, 94. [Google Scholar] [CrossRef]
  36. Urusov, A.E.; Zherdev, A.V.; Dzantiev, B.B. Towards Lateral Flow Quantitative Assays: Detection Approaches. Biosensors 2019, 9, 89. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  37. Quesada-González, D.; Merkoçi, A. Nanoparticle-based lateral flow biosensors. Biosens. Bioelectron. 2015, 73, 47–63. [Google Scholar] [CrossRef] [Green Version]
  38. Huang, X.; Aguilar, Z.P.; Xu, H.; Lai, W.; Xiong, Y. Membrane-based lateral flow immunochromatographic strip with nanoparticles as reporters for detection: A review. Biosens. Bioelectron. 2016, 75, 166–180. [Google Scholar] [CrossRef]
  39. O’Farrell, B. Lateral Flow Technology for Field-Based Applications—Basics and Advanced Developments. Top. Companion Anim. Med. 2015, 30, 139–147. [Google Scholar] [CrossRef]
  40. Parolo, C.; Sena-Torralba, A.; Bergua, J.F.; Calucho, E.; Fuentes-Chust, C.; Hu, L.; Rivas, L.; Alvarez-Diduk, R.; Nguyen, E.P.; Cinti, S.; et al. Tutorial: Design and fabrication of nanoparticle-based lateral-flow immunoassays. Nat. Protoc. 2020, 15, 3788–3816. [Google Scholar] [CrossRef]
  41. Moher, D.; Liberati, A.; Tetzlaff, J.; Altman, D.G.; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. Ann. Intern. Med. 2009, 151, 264–269. [Google Scholar] [CrossRef] [Green Version]
  42. Pai, N.P.; Vadnais, C.; Denkinger, C.; Engel, N.; Pai, M. Point-of-Care Testing for Infectious Diseases: Diversity, Complexity, and Barriers in Low- And Middle-Income Countries. PLoS Med. 2012, 9, e1001306. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  43. O’Farrell, B. Lateral Flow Immunoassay Systems: Evolution from the Current State of the Art to the Next Generation of Highly Sensitive, Quantitative Rapid Assays. In The Immunoassay Handbook. Theory and Applications of Ligand Binding, ELISA and Related Techniques, 4th ed.; Wild, D., Ed.; Elsevier: Amsterdam, The Netherlands, 2013; pp. 89–107. [Google Scholar]
  44. World Health Organization. First WHO Model List of Essential In Vitro Diagnostics; WHO Technical Report Series, No. 1017; World Health Organization: Geneva, Switzerland, 2019. [Google Scholar]
  45. World Health Organization. The Selection and Use of Essential In Vitro Diagnostics: Report of the Second Meeting of the WHO Strategic Advisory Group of Experts on In Vitro Diagnostics, 2019 (Including the Second WHO Model List of Essential In Vitro Diagnostics); WHO Technical Report Series, No. 1022; World Health Organization: Geneva, Switzerland, 2019. [Google Scholar]
  46. WHO. WHO Estimates of the Global Burden of Foodborne Diseases: Foodborne Disease Burden Epidemiology Reference Group 2007–2015. Available online: http://apps.who.int/iris/bitstream/10665/199350/1/9789241565165_eng.pdf (accessed on 17 May 2021).
  47. Anfossi, L. Immunoassays|Food applications. In Encyclopedia of Analytical Science, 3rd ed.; Worsfold, P., Townshend, A., Poole, C., Eds.; Elsevier: Amsterdam, The Netherlands, 2019; pp. 25–30. [Google Scholar]
  48. General Standard for Contaminants and Toxins in Food and Feed (CODEX STAN 193-1995). Available online: http://www.fao.org/fao-who-codexalimentarius/sh-proxy/en/?lnk=1&url=https%253A%252F%252Fworkspace.fao.org%252Fsites%252Fcodex%252FStandards%252FCXS%2B193-1995%252FCXS_193e.pdf (accessed on 27 July 2021).
  49. Di Nardo, F.; Anfossi, L. Chapter Eight—Commercial biosensors for detection of food additives, contaminants, and pathogens. In Commercial Biosensors and Their Applications. Clinical, Food, and Beyond, 1st ed.; Sezgintürk, M.K., Ed.; Elsevier: Amsterdam, The Netherlands, 2020; pp. 183–215. [Google Scholar]
  50. Anfossi, L.; Giovannoli, C.; Baggiani, C. Mycotoxinf detection. Curr. Opin. Biotechnol. 2016, 37, 120–126. [Google Scholar] [CrossRef]
  51. Veterinary Services. Available online: https://www.oie.int/fileadmin/Home/eng/Media_Center/docs/pdf/VS-FINAL-EN.pdf (accessed on 17 May 2021).
  52. Available online: https://www.oie.int/en/who-we-are/mission/ (accessed on 17 May 2021).
  53. Taylor, L.H.; Latham, S.M.; Woolhouse, M.E.J. Risk factors for human disease emergence. Philos. Trans. R. Soc. B. 2001, 356, 983–989. [Google Scholar] [CrossRef]
  54. Cummins, B.M.; Ligler, F.S.; Walker, G.M. Point-of-care diagnostic for niche applications. Biotechnol. Adv. 2016, 34, 161–176. [Google Scholar] [CrossRef] [Green Version]
  55. Flatland, B.; Freeman, K.P.; Vap, L.M.; Harr, K.E. ASVCP guidelines: Quality assurance for point-of-care testing in veterinary medicine. Vet. Clin. Pathol. 2013, 42, 405–423. [Google Scholar] [CrossRef]
  56. Buller, H.; Adam, K.; Bard, A.; Bruce, A.; Chan, K.W.; Hinchliffe, S.; Morgans, L.; Rees, G.; Reyher, K.K. Veterinary Diagnostic Practice and the Use of Rapid Tests in Antimicrobial Stewardship on UK Livestock Farms. Front. Vet. Sci. 2020, 7, 765–777. [Google Scholar] [CrossRef]
  57. World Health Organization. Global Action Plan on Antimicrobial Resistance. Available online: https://apps.who.int/iris/handle/10665/193736 (accessed on 17 May 2021).
  58. Global Framework for Development & Stewardship to Combat Antimicrobial Resistance: Draft Roadmap. Available online: https://www.who.int/publications/m/item/global-framework-for-development-stewardship-to-combat-antimicrobial-resistance-draft-roadmap (accessed on 17 May 2021).
  59. Amiard-Triquet, C. Introduction. In Aquatic Ecotoxicology, 1st ed.; Amiard-Triquet, C., Amiard, J.-C., Moneyrac, C., Eds.; Academic Press: Cambridge, MA, USA, 2015; pp. 1–23. [Google Scholar]
  60. Chapman, J.; Truong, V.K.; Elbourne, A.; Gangadoo, S.; Cheeseman, S.; Rajapaksha, P.; Latham, K.; Crawford, R.J.; Cozzolino, D. Combining Chemometrics and Sensors: Toward New Applications in Monitoring and Environmental Analysis. Chem. Rev. 2020, 120, 6048–6069. [Google Scholar] [CrossRef]
  61. Almeida, M.I.G.S.; Jayawardane, B.M.; Kolev, S.D.; McKelvie, I.D. Developments of microfluidic paper-based analytical devices (μPADs) for water analysis: A review. Talanta 2018, 177, 176–190. [Google Scholar] [CrossRef]
  62. Marquez, S.; Liu, J.; Morales-Narváez, E. Paper-based analytical devices in environmental applications and their integration with portable technologies. Curr. Opin. Environ. Sci. Health 2019, 10, 1–8. [Google Scholar] [CrossRef]
  63. Artiola, J.F.; Pepper, I.L.; Brusseau, M.L. Monitoring and characterization of the environment. In Environmental Monitoring and Characterization; Artiola, J.F., Pepper, I.L., Brusseau, M.L., Eds.; Academic Press: Cambridge, MA, USA, 2004; pp. 1–9. [Google Scholar]
  64. Amiard, J.-C.; Amiard-Triquet, C. Quality Standard Setting and Environmental Monitoring. In Aquatic Ecotoxicology, 1st ed.; Amiard-Triquet, C., Amiard, J.-C., Moneyrac, C., Eds.; Academic Press: Cambridge, MA, USA, 2015; pp. 51–76. [Google Scholar]
  65. Liu, B.; Zhuang, J.; Wei, G. Recent advances in the design of colorimetric sensors for environmental monitoring. Environ. Sci. Nano 2020, 7, 2195–2213. [Google Scholar] [CrossRef]
  66. Pena-Pereira, F.; Bendicho, C.; Pavlović, D.M.; Martín-Esteban, A.; Díaz-Álvarez, M.; Pan, Y.; Cooper, J.; Yang, Z.; Safarik, I.; Pospiskova, K.; et al. Miniaturized analytical methods for determination of environmental contaminants of emerging concern—A review. Anal. Chim. Acta 2021, 1158, 238108. [Google Scholar] [CrossRef]
  67. Cuprys, A.; Suralikerimath, N.; Pachapur, V.L.; Hegde, K.; Brar, S.K. Recent advances in nanomaterial-based sensors as tool for environmental monitoring. In Tools, Techniques and Protocols for Monitoring Environmental Contaminants; Brar, S.K., Hegde, K., Pachapur, V.L., Eds.; Elsevier: Amsterdam, The Netherlands, 2019; pp. 391–403. [Google Scholar]
  68. Geissen, V.; Mol, H.; Klumpp, E.; Umlauf, G.; Nadal, M.; van der Ploeg, M.; van der Zee, S.E.A.T.M.; Ritsema, C.J. Emerging pollutants in the environment: A challenge for water resource management. Int. Soil Water Conserv. Res. 2015, 3, 57–65. [Google Scholar] [CrossRef]
  69. Daverey, A.; Dutta, K.; Sarkar, A. An overview of analytical methodologies for environmental monitoring. In Tools, Techniques and Protocols for Monitoring Environmental Contaminants; Brar, S.K., Hegde, K., Pachapur, V.L., Eds.; Elsevier: Amsterdam, The Netherlands, 2019; pp. 3–17. [Google Scholar]
  70. Communication from the Commission to the Council and the European Parliament. A European One Health Action Plan against Antimicrobial Resistance (AMR). COM/2017/0339 Final. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:52017DC0339 (accessed on 17 May 2021).
  71. Sollweck, K.; Streich, P.; Elsner, M.; Seidel, M. A Chip-Based Colony Fusion Recombinase Polymerase Amplification Assay for Monitoring of Antimicrobial Resistance Genes and Their Carrying Species in Surface Water. ACS EST Water 2021, 1, 584–594. [Google Scholar] [CrossRef]
  72. Liu, M.; Li, Y.; Zheng, H.; Zhou, Y.; Wang, B.; Hu, Z. Development of a gold-based immunochromatographic strip assay for the detection of ancient silk. Anal. Methods 2015, 7, 7824–7830. [Google Scholar] [CrossRef]
  73. Sciutto, G.; Zangheri, M.; Anfossi, L.; Guardigli, M.; Prati, S.; Mirasoli, M.; Di Nardo, F.; Baggiani, C.; Mazzeo, R.; Roda, A. Miniaturized Biosensors to Preserve and Monitor Cultural Heritage: From Medical to Conservation Diagnosis. Angew. Chem. 2018, 57, 7385–7389. [Google Scholar] [CrossRef] [Green Version]
  74. Di Nardo, F.; Baggiani, C.; Giovannoli, C.; Spano, G.; Anfossi, L. Multicolor immunochromatographic strip test based on gold nanoparticles for the determination of aflatoxin B1 and fumonisins. Microchim. Acta 2017, 184, 1295–1304. [Google Scholar] [CrossRef]
  75. Zangheri, M.; Di Nardo, F.; Anfossi, L.; Giovannoli, C.; Baggiani, C.; Roda, A.; Mirasoli, M. Multiplex chemiluminescent biosensor for type B-fumonisins and aflatoxin B1 quantitative detection in maize flour. Analyst 2014, 140, 358–365. [Google Scholar] [CrossRef] [Green Version]
  76. Xing, C.; Liu, L.; Song, S.; Feng, M.; Kuang, H.; Xu, C. Ultrasensitive immunochromatographic assay for the simultaneous detection of five chemicals in drinking water. Biosens. Bioelectron. 2015, 66, 445–453. [Google Scholar] [CrossRef] [PubMed]
  77. Carrio, A.; Sampedro, C.; Sanchez-Lopez, J.L.; Pimienta, M.; Campoy, P. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection. Sensors 2015, 15, 29569–29593. [Google Scholar] [CrossRef] [Green Version]
  78. Zhao, Y.; Wang, H.; Zhang, P.; Sun, C.; Wang, X.; Wang, X.; Yang, R.; Wang, C.; Zhou, L. Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay. Sci. Rep. 2016, 6, 21342. [Google Scholar] [CrossRef] [PubMed]
  79. Schenk, F.; Weber, P.; Vogler, J.; Hecht, L.; Dietzel, A.; Gauglitz, G. Development of a paper-based lateral flow immunoassay for simultaneous detection of lipopolysaccharides of Salmonella serovars. Anal. Bioanal. Chem. 2018, 410, 863–868. [Google Scholar] [CrossRef] [PubMed]
  80. Sánchez-Purrà, M.; Carré-Camps, M.; De Puig, H.; Bosch, I.; Gehrke, L.; Hamad-Schifferli, K. Surface-enhanced raman spectroscopy-based sandwich immunoassays for multiplexed detection of zika and dengue viral biomarkers. ACS Infect. Dis. 2017, 3, 767–776. [Google Scholar] [CrossRef] [PubMed]
  81. Zhang, D.; Huang, L.; Liu, B.; Su, E.; Chen, H.-Y.; Gu, Z.; Zhao, X. Quantitative detection of multiplex cardiac biomarkers with encoded SERS nanotags on a single T line in lateral flow assay. Sens. Actuators B Chem. 2018, 277, 502–509. [Google Scholar] [CrossRef]
  82. Di Nardo, F.; Alladio, E.; Baggiani, C.; Cavalera, S.; Giovannoli, C.; Spano, G.; Anfossi, L. Colour-encoded lateral flow immunoassay for the simultaneous detection of aflatoxin B1 and type-B fumonisins in a single Test line. Talanta 2019, 192, 288–294. [Google Scholar] [CrossRef] [PubMed]
  83. Kim, J.; Cao, X.; Finkelstein, J.L.; Cárdenas, W.B.; Erickson, D.; Mehta, S. A two-colour multiplexed lateral flow immunoassay system to differentially detect human malaria species on a single test line. Malar. J. 2019, 18, 313. [Google Scholar] [CrossRef] [PubMed]
  84. Cavalera, S.; Di Nardo, F.; Forte, L.; Marinoni, F.; Chiarello, M.; Baggiani, C.; Anfossi, L. Switching from Multiplex to Multimodal Colorimetric Lateral Flow Immunosensor. Sensors 2020, 20, 6609. [Google Scholar] [CrossRef] [PubMed]
  85. Couturier, C.; Wada, A.; Louis, K.; Mistretta, M.; Beitz, B.; Povoguiu, M.; Ripaux, M.; Mignon, C.; Werle, B.; Lugari, A.; et al. Characterization and analytical validation of a new antigenic rapid diagnostic test for Ebola virus disease detection. PLoS Negl. Trop. Dis. 2020, 14, 0007965. [Google Scholar] [CrossRef] [Green Version]
  86. DeMers, H.L.; He, S.; Pandit, S.G.; Hannah, E.E.; Zhang, Z.; Yan, F.; Green, H.R.; Reyes, D.F.; HauI, D.; McLarty, M.E.; et al. Development of an antigen detection assay for early point-of-care diagnosis of Zaire ebolavirus. PLoS Negl. Trop. Dis. 2020, 14, e0008817. [Google Scholar] [CrossRef] [PubMed]
  87. Wonderly, B.; Jones, S.; Gatton, M.L.; Barber, J.; Killip, M.; Hudson, C.; Carter, L.; Brooks, T.; Simpson, A.J.H.; Semper, A.; et al. Comparative performance of four rapid Ebola antigen-detection lateral flow immunoassays during the 2014–2016 Ebola epidemic in West Africa. PLoS ONE 2019, 14, e0212113. [Google Scholar]
  88. Martiskainen, I.; Juntunen, E.; Salminen, T.; Vuorenpää, K.; Bayoumy, S.; Vuorinen, T.; Khanna, N.; Pettersson, K.; Batra, G.; Talha, S.M. Double-Antigen Lateral Flow Immunoassay for the Detection of Anti-HIV-1 and -2 Antibodies Using Upconverting Nanoparticle Reporters. Sensors 2021, 21, 330. [Google Scholar] [CrossRef]
  89. Xu, M.; Lu, F.; Lyu, C.; Wu, Q.; Zhang, J.; Tian, P.; Xue, L.; Xu, T.; Wang, D. Broad-range and effective detection of human noroviruses by colloidal gold immunochromatographic assay based on the shell domain of the major capsid protein. BMC Microbiol. 2021, 21, 22. [Google Scholar] [CrossRef]
  90. Yoo, S.J.; Shim, H.S.; Yoon, S.; Moon, H.-W. Evaluation of high-throughput digital lateral flow immunoassays for the detection of influenza A/B viruses from clinical swab samples. J. Med. Virol. 2020, 92, 1040–1046. [Google Scholar] [CrossRef]
  91. Suzuki, K.; Huits, R.; Phadungsombat, J.; Tuekprakhon, A.; Nakayama, E.E.; van den Berg, R.; Barbè, B.; Cnops, L.; Rahim, R.; Hasan, A.; et al. Promising application of monoclonal antibody against chikungunya virus E1-antigen across genotypes in immunochromatographic rapid diagnostic tests. Virol. J. 2020, 17, 90. [Google Scholar] [CrossRef]
  92. Xiong, Y.; Luo, Y.; Li, H.; Wu, W.; Ruan, X.; Mu, X. Rapid visual detection of dengue virus by combining reverse transcription recombinase-aided amplification with lateral-flow dipstick assay. Int. J. Infect. Dis. 2020, 95, 406–412. [Google Scholar] [CrossRef]
  93. Goux, H.J.; Raja, B.; Kourentzi, K.; Trabuco, J.R.C.; Vu, B.V.; Paterson, A.S.; Kirkpatrick, A.; Townsend, B.; Lee, M.; Truong, V.T.T.; et al. Evaluation of a nanophosphor lateral-flow assay for self-testing for herpes simplex virus type 2 seropositivity. PLoS ONE 2019, 14, e0225365. [Google Scholar] [CrossRef]
  94. Wen, T.; Huang, C.; Shi, F.J.; Zeng, X.Y.; Lu, T.; Ding, S.N.; Jiao, Y.J. Development of a lateral flow immunoassay strip for rapid detection of IgG antibody against SARS-CoV-2 virus. Analyst 2020, 145, 5345–5352. [Google Scholar] [CrossRef]
  95. Chen, Z.; Zhang, Z.; Zhai, X.; Li, Y.; Lin, L.; Zhao, H.; Bian, L.; Li, P.; Yu, L.; Wu, Y.; et al. Rapid and Sensitive Detection of anti-SARS-CoV-2 IgG, Using Lanthanide-Doped Nanoparticles-Based Lateral Flow Immunoassay. Anal. Chem. 2020, 92, 7226–7231. [Google Scholar] [CrossRef]
  96. Yu, S.; Nimse, S.B.; Kim, J.; Song, K.S.; Kim, T. Development of a Lateral Flow Strip Membrane Assay for Rapid and Sensitive Detection of the SARS-CoV-2. Anal. Chem. 2020, 92, 14139–14144. [Google Scholar] [CrossRef] [PubMed]
  97. Peng, T.; Sui, Z.; Huang, Z.; Xie, J.; Wen, K.; Zhang, Y.; Huang, W.; Mi, W.; Peng, K.; Dai, X.; et al. Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2. Sens. Actuators B Chem. 2021, 331, 129415. [Google Scholar] [CrossRef] [PubMed]
  98. Kim, H.Y.; Lee, J.H.; Kim, M.J.; Park, S.C.; Choi, M.; Lee, W.; Ku, K.B.; Kim, B.-T.; Park, E.C.; Kim, V.; et al. Development of a SARS-CoV-2-specific biosensor for antigen detection using scFv-Fc fusion proteins. Biosens. Bioelectron. 2021, 175, 112868. [Google Scholar] [CrossRef] [PubMed]
  99. Roda, A.; Cavalera, S.; Di Nardo, F.; Calabria, D.; Rosati, S.; Simoni, P.; Colitti, B.; Baggiani, C.; Roda, M.; Anfossi, L. Dual lateral flow optical/chemiluminescence immunosensors for the rapid detection of salivary and serum IgA in patients with COVID-19 disease. Biosens. Bioelectron. 2021, 172, 112765. [Google Scholar] [CrossRef]
  100. Cavalera, S.; Colitti, B.; Rosati, S.; Ferrara, G.; Bertolotti, L.; Nogarol, C.; Guiotto, C.; Cagnazzo, C.; Denina, M.; Fagioli, F.; et al. A multi-target lateral flow immunoassay enabling the specific and sensitive detection of total antibodies to SARS-CoV-2. Talanta 2021, 223, 121737. [Google Scholar] [CrossRef]
  101. Zhu, M.; Zhang, J.; Cao, J.; Ma, J.; Li, X.; Shiet, F. Ultrasensitive dual-color rapid lateral flow immunoassay via gold nanoparticles with two different morphologies for the serodiagnosis of human brucellosis. Anal. Bioanal. Chem. 2019, 411, 8033–8042. [Google Scholar] [CrossRef]
  102. Han, Y.; Dai, W.; Meng, F.; Gan, X.; Liu, M.; Deng, X.; Li, Y.; Wang, G. Diagnosis of Helicobacter pylori infection in the elderly using an immunochromatographic assay-based stool antigen test. Microbiol. Open 2020, 9, e1102. [Google Scholar] [CrossRef]
  103. Romero Herrero, D.; Soler-Palacin, P.; Burgos Cibrian, J.; Falcó Ferrer, V.; Anton Pagarolas, A.; Martin-Gomez, M.T. Detection of Streptococcus pneumoniae antigen in pleural fluid: Usefulness of an immunofluorescence-based lateral flow assay for the diagnosis of pneumococcal pneumonia. Diagn Microbiol. Infect Dis. 2020, 98, 115162. [Google Scholar] [CrossRef]
  104. Salminen, T.; Mehdi, F.; Rohila, D.; Kumar, M.; Talha, S.M.; Prakash, J.A.J.; Khanna, N.; Pettersson, K.; Batra, G. Ultrasensitive and Robust Point-of-Care Immunoassay for the Detection of Plasmodium falciparum Malaria. Anal. Chem. 2020, 92, 15766–15772. [Google Scholar] [CrossRef]
  105. Lee, S.H.; Hwang, J.; Kim, K.; Jeon, J.; Lee, S.; Ko, J.; Lee, J.; Kang, M.; Chung, D.R.; Choo, J. Quantitative Serodiagnosis of Scrub Typhus Using Surface-Enhanced Raman Scattering-Based Lateral Flow Assay Platforms. Anal. Chem. 2019, 91, 12275–12282. [Google Scholar] [CrossRef]
  106. Choi, J.Y.; Hii, K.C.; Bailey, E.S.; Chuang, J.Y.; Tang, W.Y.; Yuen Wong, E.K.; Ti, T.; Pau, K.S.; Berita, A.; Saihidi, I.; et al. Burkholderia pseudomallei Detection among Hospitalized Patients, Sarawak. Am. J. Trop. Med. Hyg. 2020, 102, 388–391. [Google Scholar] [CrossRef] [PubMed]
  107. Tomás, A.L.; de Almeida, M.P.; Cardoso, F.; Pinto, M.; Pereira, E.; Franco, R.; Matos, O. Development of a Gold Nanoparticle-Based Lateral-Flow Immunoassay for Pneumocystis pneumonia Serological Diagnosis at Point-of-Care. Front. Microbiol. 2020, 10, 2917. [Google Scholar] [CrossRef]
  108. Boonroumkaew, P.; Sadaow, L.; Sanpool, O.; Rodpai, R.; Thanchomnang, T.; Phupiewkham, W.; Intapan, P.M.; Maleewong, W. Effectiveness of Strongyloides Recombinant IgG Immunoreactive Antigen in Detecting IgG and IgG4 Subclass Antibodies for Diagnosis of Human Strongyloidiasis Using Rapid Immunochromatographic Tests. Diagnostics 2020, 10, 615. [Google Scholar] [CrossRef]
  109. Sadaow, L.; Sanpool, O.; Rodpai, R.; Boonroumkaew, P.; Maleewong, W.; Intapan, P.M. Development of immunochromatographic device as a point-of-care tool for serodiagnosis of human strongyloidiasis cases. Eur. J. Clin. Microbiol. Infect. Dis. 2020, 39, 465–470. [Google Scholar] [CrossRef] [Green Version]
  110. Matsui, H.; Higashide, M.; Hanaki, H. Evaluation of a rapid immunochromatographic test for the detection of Candida species from oropharyngeal samples. J. Microbiol. Methods 2020, 179, 106090. [Google Scholar] [CrossRef]
  111. Cáceres, D.H.; Gómez, B.L.; Tobón, A.M.; Chiller, T.M.; Lindsley, M.D. Evaluation of a Histoplasma antigen lateral flow assay for the rapid diagnosis of progressive disseminated histoplasmosis in Colombian patients with AIDS. Mycoses 2020, 63, 139–144. [Google Scholar] [CrossRef]
  112. Ybañez, R.H.D.; Nishikawa, Y. Serological detection of T. gondii infection in humans using an immunochromatographic assay based on dense granule protein 7. Parasitol. Int. 2020, 76, 102089. [Google Scholar] [CrossRef] [PubMed]
  113. Mercier, T.; Dunbar, A.; de Kort, E.; Schauwvlieghe, A.; Reynders, M.; Guldentops, E.; Blijlevens, N.M.A.; Vonk, A.G.; Rijnders, B.; Verweij, P.E.; et al. Lateral flow assays for diagnosing invasive pulmonary aspergillosis in adult hematology patients: A comparative multicenter study. Med. Mycol. 2020, 58, 444–452. [Google Scholar] [CrossRef] [PubMed]
  114. Hunter, E.S.; Page, I.D.; Richardson, M.D.; Denning, D.W. Evaluation of the LDBio Aspergillus ICT lateral flow assay for serodiagnosis of allergic bronchopulmonary aspergillosis. PLoS ONE 2020, 15, e0238855. [Google Scholar] [CrossRef] [PubMed]
  115. Sadaow, L.; Yamasaki, H.; Morishima, Y.; Sanpool, O.; Rodpai, R.; Janwan, P.; Boonroumkaew, P.; Maleewong, W.; Intapan, P.M. Effectiveness of Fasciola gigantica excretory-secretory and recombinant cathepsin L antigens for rapid diagnosis of human fascioliasis using immunochromatographic devices. Parasitol. Res. 2020, 119, 3691–3698. [Google Scholar] [CrossRef] [PubMed]
  116. Silva, E.D.; Silva, Â.A.O.; Santos, E.F.; Leony, L.M.; Freitas, N.E.M.; Daltro, R.T.; Ferreira, A.G.P.; Diniz, R.L.; Bernardo, A.R.A.O.; Krieger, M.A.; et al. Development of a New Lateral Flow Assay Based on IBMP-8.1 and IBMP-8.4 Chimeric Antigens to Diagnose Chagas Disease. BioMed. Res. Int. 2020, 2020, 1803515. [Google Scholar] [CrossRef]
  117. Somboonpatarakun, C.; Intapan, P.M.; Sadaow, L.; Rodpai, R.; Sanpool, O.; Maleewong, W. Development of an Immunochromatographic Device to Detect Antibodies for Rapid Diagnosis of Human Angiostrongyliasis. Parasitology 2020, 147, 194–198. [Google Scholar] [CrossRef]
  118. Sun, Y.; Li, Z.; Liang, W.; Zhang, Y.; Song, W.; Song, J.; Xue, K.; Wang, M.; Sun, W.; Gu, J.; et al. A novel immunochromatographic strips assay for rapid and simple detection of systemic lupus erythematosus. Sci. Rep. 2020, 10, 14178. [Google Scholar] [CrossRef]
  119. Huang, D.; Ying, H.; Jiang, D.; Liu, F.; Tian, Y.; Du, C.; Zhang, L.; Pu, X. Rapid and sensitive detection of interleukin-6 in serum via time-resolved lateral flow immunoassay. Anal. Biochem. 2020, 588, 113468. [Google Scholar] [CrossRef] [PubMed]
  120. Ki, H.; Jang, H.; Oh, J.; Han, G.-R.; Lee, H.; Kim, S.; Kim, M.-G. Simultaneous Detection of Serum Glucose and Glycated Albumin on a Paper-Based Sensor for Acute Hyperglycemia and Diabetes Mellitus. Anal. Chem. 2020, 92, 11530–11534. [Google Scholar] [CrossRef]
  121. Ki, H.; Oh, J.; Hana, G.-R.; Kim, M.-G. Glycation ratio determination through simultaneous detection of human serum albumin and glycated albumin on an advanced lateral flow immunoassay sensor. Lab Chip 2020, 20, 844–851. [Google Scholar] [CrossRef] [PubMed]
  122. Hainsworth, D.P.; Gangula, A.; Ghoshdastidar, S.; Kannan, R.; Upendran, A. Diabetic Retinopathy Screening Using a Gold Nanoparticle-Based Paper Strip Assay for the At-Home Detection of the Urinary Biomarker 8-Hydroxy-2′-Deoxyguanosine. Am. J. Ophthalmol. 2020, 213, 306–319. [Google Scholar] [CrossRef]
  123. Nelson, A.C.; Motum, P.I.; Emeto, T.I. Evaluation of an immunochromatographic test for alpha thalassaemia screening in a multi-ethnic population. Int. J. Lab. Hematol. 2019, 41, 397–403. [Google Scholar] [CrossRef]
  124. Choi, E.-S.; Hasan Al Faruque, H.; Kim, J.-H.; Cho, J.-H.; Park, K.M.; Kim, E. Immunochromatographic assay to detect α-tubulin in urine for the diagnosis of kidney injury. J. Clin. Lab. Anal. 2020, 34, e23015. [Google Scholar] [CrossRef] [Green Version]
  125. Li, K.; Li, X.; Fan, Y.; Yang, C.; Lv, X. Simultaneous detection of gastric cancer screening biomarkers plasma pepsinogen I/II using fluorescent immunochromatographic strip coupled with a miniature analytical device. Sens. Actuators B Chem. 2019, 286, 272–281. [Google Scholar] [CrossRef]
  126. Oliveira, C.M.; Musselwhite, L.W.; de Paula Pantano, N.; Vazquez, F.L.; Smith, J.S.; Schweizer, J.; Belmares, M.; Possati-Resende, J.C.; de Andrade Vieira, M.; Longatto-Filho, A.; et al. Detection of HPV E6 oncoprotein from urine via a novel immunochromatographic assay. PLoS ONE 2020, 15, e0232105. [Google Scholar] [CrossRef] [Green Version]
  127. Bayoumy, S.; Hyytiä, H.; Leivo, J.; Talha, S.M.; Huhtinen, K.; Poutanen, M.; Hynninen, J.; Perheentupa, A.; Lamminmäki, U.; Gidwani, K.; et al. Glycovariant-based lateral flow immunoassay to detect ovarian cancer–associated serum CA125. Commun. Biol. 2020, 3, 460. [Google Scholar] [CrossRef]
  128. Lei, Q.; Zhao, L.; Ye, S.; Sun, Y.; Xie, F.; Zhang, H.; Zhou, F.; Wu, S. Rapid and quantitative detection of urinary Cyfra21-1 using fluorescent nanosphere-based immunochromatographic test strip for diagnosis and prognostic monitoring of bladder cancer. Artif. Cells Nanomed. Biotechnol. 2019, 47, 4266–4272. [Google Scholar] [CrossRef] [Green Version]
  129. Di Nardo, F.; Occhipinti, S.; Gontero, P.; Cavalera, S.; Chiarello, M.; Baggiani, C.; Anfossi, L. Detection of urinary prostate specific antigen by a lateral flow biosensor predicting repeat prostate biopsy outcome. Sens. Actuators B Chem. 2020, 325, 128812. [Google Scholar] [CrossRef]
  130. Rey, E.G.; Finkelstein, J.L.; Erickson, D. Fluorescence lateral flow competitive protein binding assay for the assessment of serum folate concentrations. PLoS ONE 2019, 14, e0217403. [Google Scholar] [CrossRef]
  131. Di Nardo, F.; Cavalera, S.; Baggiani, C.; Giovannoli, C.; Anfossi, L. Direct vs Mediated Coupling of Antibodies to Gold Nanoparticles: The Case of Salivary Cortisol Detection by Lateral Flow Immunoassay. ACS Appl. Mater. Interfaces 2019, 11, 32758–32768. [Google Scholar] [CrossRef]
  132. Thakur, R.; Akram, F.; Rastogi, V.; Mitra, A.; Nawani, R.; Av, V.; Dubey, S.K.; Shakher, C. Development of Smartphone-Based Lateral Flow Device for the Quantification of LH and E3G Hormones. IEEE Sens. J. 2020, 20, 14491–14500. [Google Scholar] [CrossRef]
  133. Zangheri, M.; Mirasoli, M.; Guardigli, M.; Di Nardo, F.; Anfossi, L.; Baggiani, C.; Simoni, P.; Benassai, M.; Roda, A. Chemiluminescence-based biosensor for monitoring astronauts’ health status during space missions: Results from the International Space Station. Biosens. Bioelectron. 2019, 129, 260–268. [Google Scholar] [CrossRef] [PubMed]
  134. Yang, H.; He, Q.; Chen, Y.; Shen, D.; Xiao, H.; Eremin, S.A.; Cui, X.; Zhao, S. Platinum nanoflowers with peroxidase-like property in a dual immunoassay for dehydroepiandrosterone. Microchim. Acta 2020, 187, 592. [Google Scholar] [CrossRef] [PubMed]
  135. Yang, H.; He, Q.; Pan, J.; Ding, S.; Xiao, H.; Cui, X.; Zhao, S. A Pt–Ir nanocube amplified lateral flow immunoassay for dehydroepiandrosterone. Analyst 2021, 146, 2726–2733. [Google Scholar] [CrossRef]
  136. Znoyko, S.L.; Orlov, A.V.; Bragina, V.A.; Nikitin, M.P.; Nikitin, P.I. Nanomagnetic lateral flow assay for high-precision quantification of diagnostically relevant concentrations of serum TSH. Talanta 2020, 216, 120961. [Google Scholar] [CrossRef] [PubMed]
  137. Byzova, N.A.; Vengerov, Y.Y.; Voloshchuk, S.G.; Zherdev, A.V.; Dzantiev, B.B. Development of a Lateral Flow Highway: Ultra-Rapid Multitracking Immunosensor for Cardiac Markers. Sensors 2019, 19, 5494. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  138. Navarro, C.; Fishlock, S.J.; Steele, D.N.; Puttaswamy, S.V.; Lubarsky, G.; Raj, S.; Mclaughlin, J. A Point-of-Care Measurement of NT-proBNP for Heart Failure Patients. IEEE Access. 2020, 8, 138973–138983. [Google Scholar] [CrossRef]
  139. Han, G.-R.; Kim, M.-G. Highly Sensitive Chemiluminescence-Based Lateral Flow Immunoassay for Cardiac Troponin I Detection in Human Serum. Sensors 2020, 20, 2593. [Google Scholar] [CrossRef] [PubMed]
  140. He, Q.; Yang, H.; Pan, J.; Cui, X.; Shen, D.; Eremin, S.A.; Fang, Y.; Zhao, S. Lateral Flow Immunosensor for Ferritin Based on Dual Signal-Amplified Strategy by Rhodium Nanoparticles. ACS Appl. Bio Mater. 2020, 3, 8849–8856. [Google Scholar] [CrossRef]
  141. Gandhi, M.; Wang, G.; King, R.; Rodrigues, W.C.; Vincent, M.; Glidden, D.V.; Cressey, T.R.; Bacchetti, P.; Spinelli, M.A.; Okochi, H.; et al. Development and validation of the first point-of-care assay to objectively monitor adherence to HIV treatment and prevention in real-time in routine settings. AIDS 2020, 34, 255–260. [Google Scholar] [CrossRef]
  142. Cavalera, S.; Agulló, C.; Mercader, J.V.; Di Nardo, F.; Chiarello, M.; Anfossi, L.; Baggiani, C.; D’Avolio, A.; Abad-Somovilla, A.; Abad-Fuentes, A. Monoclonal antibodies with subnanomolar affinity to tenofovir for monitoring adherence to antiretroviral therapies: From hapten synthesis to prototype development. J. Mater. Chem. B 2020, 8, 10439–10449. [Google Scholar] [CrossRef]
  143. Wang, C.; Xiao, R.; Wang, S.; Yang, X.; Bai, Z.; Li, X.; Rong, Z.; Shen, B.; Wang, S. Magnetic quantum dot based lateral flow assay biosensor for multiplex and sensitive detection of protein toxins in food samples. Biosens. Bioelectron. 2019, 146, 111754. [Google Scholar] [CrossRef]
  144. Wu, K.H.; Huang, W.C.; Shyu, R.H.; Chang, S.C. Silver nanoparticle-base lateral flow immunoassay for rapid detection of Staphylococcal enterotoxin B in milk and honey. J. Inorg. Biochem. 2020, 210, 11116. [Google Scholar] [CrossRef]
  145. Li, Y.; Xu, X.; Liu, L.; Kuang, H.; Xu, L.; Xu, C. A gold nanoparticle-based lateral flow immunosensor for ultrasensitive detection of tetrodotoxin. Analyst 2020, 145, 2143–2151. [Google Scholar] [CrossRef] [PubMed]
  146. Bever, C.S.; Adams, C.A.; Hnasko, R.M.; Cheng, L.W.; Stanker, L.H. Lateral flow immunoassay (LFIA) for the detection of lethal amatoxins from mushrooms. PLoS ONE 2020, 15, e0231781. [Google Scholar] [CrossRef] [PubMed]
  147. Xu, S.; Zhang, G.; Fang, B.; Xiong, Q.; Duan, H.; Lai, W. Lateral Flow Immunoassay Based on Polydopamine-Coated Gold Nanoparticles for the Sensitive Detection of Zearalenone in Maize. ACS Appl. Mater. Interfaces 2019, 11, 31283–31290. [Google Scholar] [CrossRef]
  148. Pan, M.; Ma, T.; Yang, J.; Li, S.; Liu, S.; Wang, S. Development of Lateral Flow Immunochromatographic Assays Using Colloidal Au Sphere and Nanorods as Signal Marker for the Determination of Zearalenone in Cereals. Foods 2020, 9, 281. [Google Scholar] [CrossRef] [Green Version]
  149. Qie, Z.; Yan, W.; Gao, Z.; Meng, W.; Xiao, R.; Wang, S. Ovalbumin antibody-based fluorometric immunochromatographic lateral flow assay using CdSe/ZnS quantum dot beads as label for determination of T-2 toxin. Microchim. Acta 2019, 186, 816. [Google Scholar] [CrossRef]
  150. Li, R.; Meng, C.; Wen, Y.; Fu, W.; He, P. Fluorometric lateral flow immunoassay for simultaneous determination of three mycotoxins (aflatoxin B1, zearalenone and deoxynivalenol) using quantum dot microbeads. Microchim. Acta 2019, 186, 748. [Google Scholar] [CrossRef]
  151. Huang, X.; Huang, X.; Xie, J.; Li, X.; Huang, Z. Rapid simultaneous detection of fumonisin B1 and deoxynivalenol in grain by immunochromatographic test strip. Anal. Biochem. 2020, 606, 113878. [Google Scholar] [CrossRef]
  152. Li, X.; Wu, X.; Wang, J.; Hua, Q.; Wu, J.; Shen, X.; Sun, Y.; Lei, H. Three lateral flow immunochromatographic assays based on different nanoparticle probes for on-site detection of tylosin and tilmicosin in milk and pork. Sens. Actuators B Chem. 2019, 301, 127059. [Google Scholar] [CrossRef]
  153. Wang, Z.; Hu, S.; Bao, H.; Xing, K.; Liu, J.; Xia, J.; Lai, W.; Peng, J. Immunochromatographic assay based on time-resolved fluorescent nanobeads for the rapid detection of sulfamethazine in egg, honey, and pork. J. Sci. Food Agric. 2020, 101, 684–692. [Google Scholar] [CrossRef]
  154. Byzova, N.A.; Serchenya, T.S.; Vashkevich, I.I.; Zherdev, A.V.; Sviridov, O.V.; Dzantiev, B.B. Lateral flow immunoassay for rapid qualitative and quantitative control of the veterinary drug bacitracin in milk. Microchem. J. 2020, 156, 104884. [Google Scholar] [CrossRef]
  155. Wang, Z.; Wu, X.; Liu, L.; Xu, L.; Kuang, H.; Xu, C. Rapid and sensitive detection of diclazuril in chicken samples using a gold nanoparticle-based lateral-flow strip. Food Chem. 2020, 312, 126116. [Google Scholar] [CrossRef]
  156. Hendrickson, O.D.; Zvereva, E.A.; Popravko, D.S.; Zherdev, A.V.; Xu, C.; Dzantiev, B.B. An immunochromatographic test system for the determination of lincomycin in foodstuffs of animal origin. J. Chromatogr. B, 2020, 1141, 122014. [Google Scholar] [CrossRef]
  157. Guo, L.; Wu, X.; Cui, G.; Song, S.; Kuang, H.; Xu, C. Colloidal Gold Immunochromatographic Assay for Rapid Detection of Carbadox and Cyadox in Chicken Breast. ACS Omega 2020, 5, 1422–1429. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  158. Na, G.; Hu, X.; Yang, J.; Sun, Y.; Kwee, S.; Tang, L.; Xing, G.; Xing, Y.; Zhang, G. Colloidal gold-based immunochromatographic strip assay for the rapid detection of bacitracin zinc in milk. Food Chem. 2020, 327, 126879. [Google Scholar] [CrossRef] [PubMed]
  159. Hendrickson, O.D.; Zvereva, E.A.; Zherdev, A.V.; Godjevargova, T.; Xu, C.; Dzantiev, B.B. Development of a double immunochromatographic test system for simultaneous determination of lincomycin and tylosin antibiotics in foodstuffs. Food Chem. 2020, 318, 126510. [Google Scholar] [CrossRef] [PubMed]
  160. Zhang, X.; Zhao, F.; Sun, Y.; Mi, T.; Wang, L.; Li, Q.; Li, J.; Ma, W.; Liu, W.; Zuo, J.; et al. Development of a highly sensitive lateral flow immunoassay based on receptor-antibody-amorphous carbon nanoparticles to detect 22 β-lactams in milk. Sens. Actuators B Chem. 2020, 321, 128458. [Google Scholar] [CrossRef]
  161. Xu, X.; Wang, Z.; Guo, L.; Xu, X.; Wu, A.; Kuang, H.; Sun, L.; Song, S.; Xu, C. Sensitive Lateral Flow Immunoassay for the Residues of Imidocarb in Milk and Beef Samples. ACS Omega 2021, 6, 2559–2569. [Google Scholar] [CrossRef]
  162. Li, Y.; Jin, G.; Liu, L.; Kuang, H.; Xiao, J.; Xu, C. A portable fluorescent microsphere-based lateral flow immunosensor for the simultaneous detection of colistin and bacitracin in milk. Analyst 2021, 145, 7884–7892. [Google Scholar] [CrossRef]
  163. Zhao, M.; Yao, X.; Liu, S.; Zhang, H.; Wang, L.; Yin, X.; Su, L.; Xu, B.; Wang, J.; Lan, Q.; et al. Antibiotic and mammal IgG based lateral flow assay for simple and sensitive detection of Staphylococcus aureus. Food Chem. 2021, 339, 127955. [Google Scholar] [CrossRef] [PubMed]
  164. Wang, Q.; Long, M.; Lv, C.; Xin, S.; Han, X.; Jiang, W. Lanthanide-labeled fluorescent-nanoparticle immunochromatographic strips enable rapid and quantitative detection of Escherichia coli O157:H7 in food samples. Food Control 2020, 109, 106894. [Google Scholar] [CrossRef]
  165. Liu, C.; Fang, S.; Tian, Y.; Ma, J.; Wang, Z.; Xu, D.; Li, Y.; Hou, D.; Liu, Q. Rapid detection of Escherichia coli O157:H7 in milk, bread, and jelly by lac dye coloration-based bidirectional lateral flow immunoassay strip. J. Food Saf. 2021, 41, e12862. [Google Scholar] [CrossRef]
  166. Zhuang, L.; Gong, J.; Ji, Y.; Tian, P.; Kong, F.; Bai, H.; Gu, N.; Zhang, Y. Lateral flow fluorescent immunoassay based on isothermal amplification for rapid quantitative detection of: Salmonella spp. Analyst 2020, 145, 2367–2377. [Google Scholar] [CrossRef]
  167. Ilhan, H.; Tayyarcan, E.K.; Caglayan, M.J.; Boyaci, I.K.; Saglam, N.; Tamer, U. Replacement of antibodies with bacteriophages in lateral flow assay of Salmonella enteritidis. Biosens. Bioelectron. 2021, 189, 113383. [Google Scholar] [CrossRef]
  168. He, D.; Wu, Z.; Cui, B.; Xu, E.; Jin, Z. Establishment of a dual mode immunochromatographic assay for Campylobacter jejuni detection. Food Chem. 2019, 289, 708–713. [Google Scholar] [CrossRef]
  169. Wu, M.; Wu, Y.; Liu, C.; Tian, Y.; Fang, S.; Yang, H.; Li, B.; Liu, Q. Development and comparison of immunochromatographic strips with four nanomaterial labels: Colloidal gold, new colloidal gold, multi-branched gold nanoflowers and Luminol-reduced Au nanoparticles for visual detection of Vibrio parahaemolyticus in seafood. Aquaculture 2021, 539, 736563. [Google Scholar] [CrossRef]
  170. Anfossi, L.; Di Nardo, F.; Russo, A.; Cavalera, S.; Giovannoli, C.; Spano, G.; Baumgartner, S.; Lauter, K.; Baggiani, C. Silver and gold nanoparticles as multi-chromatic lateral flow assay probes for the detection of food allergens. Anal. Bioanal. Chem. 2019, 411, 1905–1913. [Google Scholar] [CrossRef] [Green Version]
  171. Wang, Y.; Li, Z.; Lin, H.; Siddanakoppalu, P.N.; Zhou, J.; Chen, G.; Yu, Z. Quantum-dot-based lateral flow immunoassay for the rapid detection of crustacean major allergen tropomyosin. Food Control 2019, 106, 106714. [Google Scholar] [CrossRef]
  172. Galan-Malo, P.; Pellicer, S.; Pérez, M.D.; Sánchez, L.; Razquin, P.; Mata, L. Development of a novel duplex lateral flow test for simultaneous detection of casein and β-lactoglobulin in food. Food Chem. 2019, 293, 41–48. [Google Scholar] [CrossRef]
  173. Yin, H.-Y.; Fang, T.J.; Li, Y.-T.; Fung, Y.-F.; Tsai, W.-C.; Dai, H.-Y.; Wen, H.-W. Rapidly detecting major peanut allergen-Ara h2 in edible oils using a new immunomagnetic nanoparticle-based lateral flow assay. Food Chem. 2019, 271, 505–515. [Google Scholar] [CrossRef]
  174. Zhang, M.; Li, M.; Zhao, Y.; Xu, N.; Peng, L.; Wang, Y.; Wei, X. Novel monoclonal antibody-sandwich immunochromatographic assay based on Fe3O4/Au nanoparticles for rapid detection of fish allergen parvalbumin. Food Res. Int. 2021, 142, 110102. [Google Scholar] [CrossRef] [PubMed]
  175. Hnasko, R.M.; Jackson, E.S.; Lin, A.V.; Haff, R.P.; McGarvey, J.A. A rapid and sensitive lateral flow immunoassay (LFIA) for the detection of gluten in foods. Food Chem. 2021, 355, 129514. [Google Scholar]
  176. Zhang, J.; Portela, S.B.; Horrell, J.B.; Leung, A.; Weitmann, D.R.; Artiuch, J.B.; Wilson, S.M.; Cipriani, M.; Slakey, L.K.; Burt, A.M.; et al. An integrated, accurate, rapid, and economical handheld consumer gluten detector. Food Chem. 2019, 275, 446–456. [Google Scholar] [CrossRef]
  177. Xi, J.; Yu, Q. The development of lateral flow immunoassay strip tests based on surface enhanced Raman spectroscopy coupled with gold nanoparticles for the rapid detection of soybean allergen β-conglycinin. Spectrochim. Acta A Mol. Biomol. Spectrosc. 2020, 241, 118640. [Google Scholar] [CrossRef]
  178. Li, X.; Chen, X.; Liu, Z.; Wang, J.; Hua, Q.; Liang, J.; Shen, X.; Xu, Z.; Lei, H.; Sun, Y. Latex microsphere immunochromatography for quantitative detection of dexamethasone in milk and pork. Food Chem. 2021, 345, 128607. [Google Scholar] [CrossRef]
  179. Yao, X.; Wang, Z.; Zhao, M.; Liu, S.; Su, L.; Dou, L.; Li, T.; Wang, J.; Zhang, D. Graphite-like carbon nitride-laden gold nanoparticles as signal amplification label for highly sensitive lateral flow immunoassay of 17β-estradiol. Food Chem. 2021, 347, 129001. [Google Scholar] [CrossRef]
  180. Ge, W.; Suryoprabowo, S.; Kuang, H.; Liu, L.; Song, S. Rapid detection of triazophos in cucumber using lateral flow immunochromatographic assay. Food Agric. Immunol. 2020, 31, 1051–1060. [Google Scholar] [CrossRef]
  181. Cevallos-Cedeño, R.E.; Agulló, C.; Abad-Fuentes, A.; Abad-Somovilla, A.; Mercader, J.V. Enzyme and lateral flow monoclonal antibody-based immunoassays to simultaneously determine spirotetramat and spirotetramat-enol in foodstuffs. Sci Rep. 2021, 11, 1809. [Google Scholar] [CrossRef]
  182. Wu, K.-H.; Huang, W.-C.; Chang, S.-C.; Kao, C.-H.; Shyu, R.-H. Colloidal silver-based lateral flow immunoassay for rapid detection of melamine in milk and animal feed. Mater. Chem. Phys. 2019, 231, 121–130. [Google Scholar] [CrossRef]
  183. Chen, Q.; Qie, M.; Peng, X.; Chend, Y.; Wang, Y. Immunochromatographic assay for melamine based on luminescent quantum dot beads as signaling probes. RSC Adv. 2020, 10, 3307. [Google Scholar] [CrossRef] [Green Version]
  184. Sharma, R.; Verma, A.; Shinde, N.; Mann, B.; Gandhi, K.; Wichers, J.H.; van Amerongen, A. Adulteration of cow’s milk with buffalo’s milk detected by an on-site carbon nanoparticles-based lateral flow immunoassay. Food Chem. 2021, 351, 129311. [Google Scholar] [CrossRef] [PubMed]
  185. Zhao, M.; Wang, B.; Xiang, L.; Xiong, C.; Shi, Y.; Wu, L.; Meng, X.; Dong, G.; Xie, Y.; Sun, W. A novel onsite and visual molecular technique to authenticate saffron (Crocus sativus) and its adulterants based on recombinase polymerase amplification. Food Control 2019, 100, 117–121. [Google Scholar] [CrossRef]
  186. Qin, P.; Qiao, D.; Xu, J.; Song, Q.; Yao, L.; Lu, J.; Chen, W. Rapid visual sensing and quantitative identification of duck meat in adulterated beef with a lateral flow strip platform. Food Chem. 2019, 294, 224–230. [Google Scholar] [CrossRef]
  187. Zhang, C.; Zhang, X.; Liao, G.; Shang, Y.; Ge, C.; Chen, R.; Wang, Y.; Xu, W. Species-specific TM-LAMP and Trident-like lateral flow biosensor for on-site authenticity detection of horse and donkey meat. Sens. Actuators B Chem. 2019, 301, 127039. [Google Scholar] [CrossRef]
  188. Magiati, M.; Myridaki, V.M.; Christopoulos, T.K.; Kalogianni, D.P. Lateral flow test for meat authentication with visual detection. Food Chem. 2019, 274, 803–807. [Google Scholar] [CrossRef] [PubMed]
  189. Zvereva, E.A.; Byzova, N.A.; Hendrickson, O.D.; Popravko, D.S.; Belichenko, K.A.; Dzantiev, B.B.; Zherdev, A.V. Immunochromatographic Detection of Myoglobin as a Specific Biomarker of Porcine Muscle Tissues in Meat Products. Appl. Sci. 2020, 10, 7437. [Google Scholar] [CrossRef]
  190. Zhao, L.; Li, S.; Hua, M.Z.; Liu, J.; Zhang, H.; Hu, Y.; Chen, Y.; Lu, X.; Zheng, W. Development of a species-specific PCR coupled with lateral flow immunoassay for the identification of goose ingredient in foods. Food Control 2020, 114, 107240. [Google Scholar] [CrossRef]
  191. Hendrickson, O.D.; Zvereva, E.A.; Vostrikova, N.L.; Chernukha, I.M.; Dzantiev, B.B.; Zherdev, A.V. Lateral flow immunoassay for sensitive detection of undeclared chicken meat in meat products. Food Chem. 2021, 344, 128598. [Google Scholar] [CrossRef]
  192. Chen, Y.; Wang, Y.; Xiao, M.; Wei, S.; Yang, H.; Yin, R. Polymerase chain reaction with lateral flow sensor assay for the identification of horse meat in raw and processed meat products. Food Chem. 2021, 345, 128840. [Google Scholar] [CrossRef]
  193. Zhang, S.-W.; Sun, Y.-Y.; Sun, Y.-M.; Wang, H.; Li, Z.-F.; Xu, Z.-L. Visual upconversion nanoparticle-based immunochromatographic assay for the semi-quantitative detection of sibutramine. Anal. Bioanal. Chem. 2020, 412, 8135–8144. [Google Scholar] [CrossRef]
  194. Zhou, S.; Xu, X.; Wang, L.; Guo, L.; Liu, L.; Kuang, H.; Xu, C. A fluorescence based immunochromatographic sensor for monitoring chlorpheniramine and its comparison with a gold nanoparticle-based lateral-flow strip. Analyst 2021, 146, 3589. [Google Scholar] [CrossRef] [PubMed]
  195. Miao, F.; Zhang, J.; Li, N.; Chen, T.; Wang, L.; Zhang, F.; Mi, L.; Zhang, J.; Wang, S.; Wang, Y.; et al. Rapid and sensitive recombinase polymerase amplification combined with lateral flow strip for detecting African swine fever virus. Front. Microbiol. 2019, 10, 1004. [Google Scholar] [CrossRef]
  196. Wang, X.; Ji, P.; Fan, H.; Dang, L.; Wan, W.; Liu, S.; Li, Y.; Yu, W.; Li, X.; Ma, X.; et al. CRISPR/Cas12a technology combined with immunochromatographic strips for portable detection of African swine fever virus. Commun. Biol. 2020, 3, 62. [Google Scholar] [CrossRef] [Green Version]
  197. Tenzin, T.; Lhamo, K.; Rai, P.B.; Tshering, D.; Jamtsho, P.; Namgyal, J.; Wangdi, T.; Letho, S.; Rai, T.; Jamtsho, S.; et al. Evaluation of a rapid immunochromatographic test kit to the gold standard fluorescent antibody test for diagnosis of rabies in animals in Bhutan. BMC Vet. Res. 2020, 16, 183. [Google Scholar] [CrossRef]
  198. Kimitsuki, K.; Saito, N.; Yamada, K.; Park, C.-H.; Inoue, S.; Suzuki, M.; Saito-Obata, M.; Kamiya, Y.; Manalo, D.L.; Demetria, C.S.; et al. Evaluation of the diagnostic accuracy of lateral flow devices as a tool to diagnose rabies in post-mortem animals. PLoS Negl. Trop. Dis. 2020, 14, e0008844. [Google Scholar] [CrossRef]
  199. Liu, J.; Gao, R.; Shi, H.; Cong, G.; Chen, J.; Zhang, X.; Shi, D.; Cao, L.; Wang, X.; Zhang, J.; et al. Development of a rapid immunochromatographic strip test for the detection of porcine epidemic diarrhea virus specific SIgA in colostrum. J. Virol. Methods 2020, 279, 113855. [Google Scholar] [CrossRef]
  200. Xu, F.; Jin, Z.; Zou, S.; Chen, C.; Song, Q.; Deng, S.; Xiao, W.; Zhang, X.; Jia, A.; Tang, Y. EuNPs-mAb fluorescent probe based immunochromatographic strip for rapid and sensitive detection of porcine epidemic diarrhea virus. Talanta 2020, 214, 120865. [Google Scholar] [CrossRef]
  201. Li, Z.; Zhao, F.; Tang, T.; Wang, M.; Yu, X.; Wang, R.; Li, Y.; Xu, Y.; Tang, L.; Wang, L.; et al. Development of a Colloidal Gold Immunochromatographic Strip Assay for Rapid Detection of Bovine Rotavirus. Viral Immunol. 2019, 32, 393–401. [Google Scholar] [CrossRef]
  202. Wang, H.; Guan, J.; Liu, X.; Shi, Y.; Wu, Q.; Luo, M.; Zhu, Y.; Wang, Z.; Wang, L.; Pan, Y. Rapid detection of avian leukosis virus using a fluorescent microsphere immunochromatographic test strip assay. Poult. Sci. 2019, 98, 6492–6496. [Google Scholar] [CrossRef]
  203. Liu, I.-L.; Lin, Y.-C.; Lin, Y.-C.; Jian, C.-Z.; Cheng, I.-C.; Chen, H.-W. A Novel Immunochromatographic Strip for Antigen Detection of Avian Infectious Bronchitis Virus. Int. J. Mol. Sci. 2019, 20, 2216. [Google Scholar] [CrossRef] [Green Version]
  204. Yang, F.; Li, Y.; Jin, X.; Xu, Q.; Cheng, F.; Wang, X. Immunosensor-based rapid quantitative detection of Newcastle disease virus antibodies using innovative gold immunochromatographic assay. J. Appl. Microbiol. 2020, 129, 1751–1757. [Google Scholar] [CrossRef]
  205. Hou, F.; Bai, M.; Zhang, Y.; Liu, H.; Sun, S.; Guo, H. Fluorescent immunochromatographic assay for quantitative detection of the foot-and-mouth disease virus serotype O antibody. Microchem. J. 2020, 155, 104690. [Google Scholar] [CrossRef]
  206. Yang, M.; Mudabuka, B.; Quizon, K.; Nfon, C. Generation of monoclonal antibodies against foot-and-mouth disease virus SAT 2 and the development of a lateral flow strip test for virus detection. Transbound. Emerg. Dis. 2019, 66, 1158–1166. [Google Scholar] [CrossRef]
  207. Wang, S.; Wen, Y.; An, T.; Duan, G.; Sun, M.; Ge, J.; Li, X.; Yang, K.; Cai, X. Development of an Immunochromatographic Strip for Rapid Detection of Canine Adenovirus. Front. Microbiol. 2019, 10, 2882. [Google Scholar] [CrossRef]
  208. Manasa, M.; Revathi, P.; Prudhvi Chand, M.; Maroudam, V.; Navaneetha, P.; Dhinakar Raj, G.; Kavi Kishor, P.B.; De, B.; Rathnagiri, P. Protein-G-based lateral flow assay for rapid serodiagnosis of brucellosis in domesticated animals. J. Immunoassay Immunochem. 2019, 40, 149–158. [Google Scholar] [CrossRef]
  209. Syahruni, S.; Hartati, Y.W.; Yusuf, M.; Kusumawardani, S.; Wibawan, I.Y.T.; Arnafia, W.; Sibit, G.; Subroto, T. Development of lateral flow assay based on anti-IBDV IgY for the rapid detection of Gumboro disease in poultry. J. Virol. Methods 2021, 291, 114065. [Google Scholar] [CrossRef]
  210. Nagasawa, Y.; Kiku, Y.; Sugawara, K.; Yabusaki, N.; Oono, K.; Fujii, K.; Suzuki, T.; Maehana, K.; Hayashi, T. Rapid Staphylococcus aureus Detection From Clinical Mastitis Milk by Colloidal Gold Nanoparticle-Based Immunochromatographic Strips. Front. Vet. Sci. 2020, 6, 504. [Google Scholar] [CrossRef]
  211. Alhussien, M.N.; Dang, A.K. Sensitive and rapid lateral-flow assay for early detection of subclinical mammary infection in dairy cows. Sci. Rep. 2020, 10, 11161. [Google Scholar] [CrossRef]
  212. Griffioen, K.; Cornelissen, J.; Heuvelink, A.; Adusei, D.; Mevius, D.; van der Wal, F.J. Development and evaluation of 4 loop-mediated isothermal amplification assays to detect mastitis-causing bacteria in bovine milk samples. J. Dairy Sci. 2020, 103, 8407–8420. [Google Scholar] [CrossRef]
  213. Ashforda, R.T.; Anderson, P.; Waring, L.; Davé, D.; Smith, F.; Delahay, R.J.; Gormley, E.; Chambers, M.A.; Sawyer, J.; Leselliera, S. Evaluation of the Dual Path Platform (DPP) VetTB assay for the detection of Mycobacterium bovis infection in badgers. Prev. Vet. Med. 2020, 180, 105005. [Google Scholar] [CrossRef] [PubMed]
  214. Fresco-Taboada, A.; Risalde, M.; Gortázar, C.; Tapia, I.; González, I.; Venteo, Á.; Sanz, A.; Rueda, P. A lateral flow assay for the rapid diagnosis of Mycobacterium bovis infection in wild boar. Transbound. Emerg. Dis. 2019, 66, 2175–2179. [Google Scholar] [CrossRef] [PubMed]
  215. Serhan, W.S.; Khan, R.A.; Gasim, E.F.; Alketbi, M.S.; De Massis, F.; Calistri, P.; Giovannini, A.; Al Hosani, M.A.; Al Jaberi, S.A.; Al Mansoori, A.M.; et al. Performance of an Immunochromatographic Test (ICT) in Comparison to Some Commonly Used Serological Tests for the Diagnosis of Brucellosis in Dromedary Camels (Camelus dromedarius). Microorganisms 2019, 7, 591. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  216. Stuart Tayebwa, D.; Magdy Beshbishy, A.; Batiha, G.E.-S.; Komugisha, M.; Joseph, B.; Vudriko, P.; Yahia, R.; Alkazmi, L.; Hetta, H.F.; Yokoyama, N.; et al. Assessing the Immunochromatographic Test Strip for Serological Detection of Bovine Babesiosis in Uganda. Microorganisms 2020, 8, 1110. [Google Scholar] [CrossRef]
  217. Ganzinelli, S.; Benitez, D.; Gantuya, S.; Guswanto, A.; Florin-Christensen, M.; Schnittger, L.; Igarashi, I. Highly sensitive nested PCR and rapid immunochromatographic detection of Babesia bovis and Babesia bigemina infection in a cattle herd with acute clinical and fatal cases in Argentina. Transbound. Emerg. Dis. 2020, 67, 159–164. [Google Scholar] [CrossRef] [PubMed]
  218. Kumar, R.; Yadav, S.C.; Kumar, S.; Dilbaghi, N. Development of membrane-based flow-through assay for detection of trypanosomosis in equines. J. Parasit. Dis. 2020, 44, 99–104. [Google Scholar] [CrossRef]
  219. Xifeng, W.; Mengfan, Q.; Kai, Z.; Guowu, Z.; Jing, L.; Lixia, W.; Jun, Q.; Qingling, M.; Shasha, G.; Yunfu, H.; et al. Development and evaluation of a colloidal gold immunochromatographic assay based on recombinant protein CatL1D for serodiagnosis of sheep fasciolosis. J. Helminthol. 2019, 94, e98. [Google Scholar] [CrossRef]
  220. Garcia, V.S.; Guerrero, S.; Gugliotta, L.; Gonzalez, V.D.G. A lateral flow immunoassay based on colored latex particles for detection of canine visceral leishmaniasis. Acta Trop. 2020, 212, 105643. [Google Scholar] [CrossRef]
  221. Karimi Kakh, M.; Golchin, M.; Kazemi Arababadi, M.; Daneshvar, H. Application of the Leishmania infantum 21-kDa recombinant protein for the development of an immunochromatographic test. Parasite Immunol. 2020, 42, e12770. [Google Scholar] [CrossRef] [PubMed]
  222. Ybañez, R.H.D.; Kyan, H.; Nishikawa, Y. Detection of antibodies against Toxoplasma gondii in cats using an immunochromatographic test based on GRA7 antigen. J. Vet. Med. Sci. 2020, 82, 441–445. [Google Scholar] [CrossRef] [Green Version]
  223. Oertly, M.; Gerber, V.; Anhold, H.; Chan, D.-S.; Pusterla, N. The Accuracy of Serum Amyloid A in Determining Early Inflammation in Horses After Long-Distance Transportation by Air. J. Equine Vet. Sci. 2021, 97, 103337. [Google Scholar] [CrossRef] [PubMed]
  224. Masello, M.; Lu, Z.; Erickson, D.; Gavalchin, J.; Giordano, J.O. A lateral flow-based portable platform for determination of reproductive status of cattle. J. Dairy Sci. 2020, 103, 4743–4753. [Google Scholar] [CrossRef] [PubMed]
  225. Lan, J.; Sun, W.; Chen, L.; Zhou, H.; Fan, Y.; Diao, X.; Wang, B.; Zhao, H. Simultaneous and rapid detection of carbofuran and 3-hydroxy-carbofuran in water samples and pesticide preparations using lateral-flow immunochromatographic assay. Food Agric. Immunol. 2020, 31, 165–175. [Google Scholar] [CrossRef] [Green Version]
  226. Li, Y.; Liu, L.; Kuang, H.; Xu, C. Preparing monoclonal antibodies and developing immunochromatographic strips for paraquat determination in water. Food Chem. 2020, 311, 125897. [Google Scholar] [CrossRef]
  227. Ruan, X.; Wang, X.Y.; Kwon, E.Y.; Wang, L.; Cheng, N.; Niu, X.; Ding, S.; Van Wie, B.J.; Lin, Y.; Du, D. Nanomaterial-enhanced 3D-printed sensor platform for simultaneous detection of atrazine and acetochlor. Biosens. Bioelectron. 2021, 184, 113238. [Google Scholar] [CrossRef]
  228. Cheng, N.; Shi, Q.; Zhu, C.; Li, S.; Lin, Y.; Du, D. Pt–Ni(OH)2 nanosheets amplified two-way lateral flow immunoassays with smartphone readout for quantification of pesticides. Biosens. Bioelectron. 2019, 142, 111498. [Google Scholar] [CrossRef]
  229. Hassan, A.H.A.; Bergua, J.F.; Morales-Narváez, E.; Mekoçi, A. Validity of a single antibody-based lateral flow immunoassay depending on graphene oxide for highly sensitive determination of E. coli O157:H7 in minced beef and river water. Food Chem. 2019, 297, 124965. [Google Scholar] [CrossRef]
  230. Rames, E.K.; Macdonald, J. Rapid assessment of viral water quality using a novel recombinase polymerase amplification test for human adenovirus. Appl. Microbiol. Biotechnol. 2019, 103, 8115–8125. [Google Scholar] [CrossRef]
  231. Prentice, K.W.; Depalma, L.; Ramage, J.G.; Sarwar, J.; Parameswaran, N.; Petersen, J.; Yockey, B.; Young, J.; Joshi, M.; Thirunavvukarasu, N.; et al. Comprehensive Laboratory Evaluation of a Lateral Flow Assay for the Detection of Yersinia pestis. Health Secur. 2019, 17, 439–453. [Google Scholar] [CrossRef] [Green Version]
  232. Berlina, A.N.; Komova, N.S.; Zherdev, A.V.; Dzantiev, B.B. Combination of phenylboronic acid and oligocytosine for selective and specific detection of lead(ii) by lateral flow test strip. Anal. Chim. Acta. 2021, 1155, 338318. [Google Scholar] [CrossRef]
  233. Schwenke, K.U.; Spiehl, D.; Krauße, M.; Riedler, L.; Ruppenthal, A.; Villforth, K.; Meckel, T.; Biesalski, M.; Rupprecht, D.; Schwall, G. Analysis of free chlorine in aqueous solution at very low concentration with lateral flow tests. Sci. Rep. 2019, 9, 17212. [Google Scholar] [CrossRef]
  234. Zhang, C.; Chen, G.; Wang, Y.; Zhou, J.; Li, C. Establishment and application of hyperbranched rolling circle amplification coupled with lateral flow dipstick for the sensitive detection of Karenia mikimotoi. Harmful Algae 2019, 84, 151–160. [Google Scholar] [CrossRef]
  235. Fu, M.; Chen, G.; Zhang, C.; Wang, Y.; Sun, R.; Zhou, J. Rapid and sensitive detection method for Karlodinium veneficum by recombinase polymerase amplification coupled with lateral flow dipstick. Harmful Algae 2019, 84, 1–9. [Google Scholar] [CrossRef] [PubMed]
  236. Zvereva, E.A.; Hendrickson, O.D.; Zherdev, A.V.; Dzantiev, B.B. Immunochromatographic tests for the detection of microcystin-LR toxin in water and fish samples. Anal. Methods 2020, 12, 392–400. [Google Scholar] [CrossRef]
  237. Yan, X.; Persaud, K.C. The Optimization of a Lateral Flow Immunoassay for Detection of Aflatoxin B1 in Potable Water Samples. IEEE Sens. J. 2019, 19, 404–412. [Google Scholar] [CrossRef] [Green Version]
  238. Dzantiev, B.B.; Nadezhda, A.; Taranova, N.A.; Semeykina, A.A.; Zherdev, A.V. Lateral flow immunoassay for bisphenol A: Development of test strips and their application for ecological monitoring. J. Phys. Conf. Ser. 2019, 1172, 012088. [Google Scholar] [CrossRef]
  239. Ren, S.; Li, Q.; Wang, J.; Fan, B.; Bai, J.; Peng, Y.; Li, S.; Han, D.; Wu, J.; Wang, J.; et al. Development of a fast and ultrasensitive black phosphorus-based colorimetric/photothermal dual-readout immunochromatography for determination of norfloxacin in tap water and river water. J. Hazard. Mater. 2021, 402, 123781. [Google Scholar] [CrossRef]
  240. Zhang, C.; Wu, X.; Li, D.; Hu, J.; Wan, D.; Zhang, Z.; Hammock, B.D. Development of nanobody-based flow-through dot ELISA and lateral-flow immunoassay for rapid detection of 3-phenoxybenzoic acid. Anal. Methods 2021, 13, 1757–1765. [Google Scholar] [CrossRef]
  241. Selvarajan, R.; Kanichelvam, P.S.; Balasubramanian, V.; Subramanian, S.S. A rapid and sensitive lateral flow immunoassay (LFIA) test for the on-site detection of banana bract mosaic virus in banana plants. J. Virol. Methods 2020, 284, 113929. [Google Scholar] [CrossRef] [PubMed]
  242. Ghosh, D.K.; Kokane, S.B.; Gowda, S. Development of a reverse transcription recombinase polymerase based isothermal amplification coupled with lateral flow immunochromatographic assay (CTV-RT-RPA-LFICA) for rapid detection of Citrus tristeza virus. Sci. Rep. 2020, 10, 20593. [Google Scholar] [CrossRef]
  243. Ni, P.; Liu, L.; Hao, C.; Xu, X.; Song, S.; Kuang, H.; Xu, C. Rapid and Sensitive Immunochromatographic Method-Based Monoclonal Antibody for the Quantitative Detection of Metalaxyl in Tobacco. ACS Omega 2020, 5, 18168–18175. [Google Scholar] [CrossRef] [PubMed]
  244. Razo, S.C.; Safenkova, I.V.; Drenova, N.V.; Kharchenko, A.A.; Tsymbal, Y.S.; Varitsev, Y.A.; Zherdev, A.V.; Pakina, E.N.; Dzantiev, B.B. New lateral flow immunoassay for on-site detection of Erwinia amylovora and its application on various organs of infected plants. Physiol. Mol. Plant Pathol. 2021, 114, 101637. [Google Scholar] [CrossRef]
  245. Ivanov, A.V.; Shmyglya, I.V.; Zherdev, A.V.; Dzantiev, B.B.; Safenkova, I.V. The Challenge for Rapid Detection of High-Structured Circular RNA: Assay of Potato Spindle Tuber Viroid Based on Recombinase Polymerase Amplification and Lateral Flow Tests. Plants 2020, 9, 1369. [Google Scholar] [CrossRef]
  246. Ivanov, A.V.; Safenkova, I.V.; Drenova, N.V.; Zherdev, A.V.; Dzantiev, B.B. Development of lateral flow assay combined with recombinase polymerase amplification for highly sensitive detection of Dickeya solani. Mol. Cell. Probes 2020, 53, 101622. [Google Scholar] [CrossRef]
  247. Lei, X.; Xu, X.; Liu, L.; Kuang, H.; Xu, L.; Hao, C.; Xu, C. Rapid quantitative determination of fentanyl in human urine and serum using a gold-based immunochromatographic strip sensor. J. Mater. Chem. B 2020, 8, 8573–8584. [Google Scholar] [CrossRef]
  248. Angelini, D.J.; Biggs, T.D.; Prugh, A.M.; Smith, J.A.; Hanburger, J.A.; Llano, B.; Avelar, R.; Ellis, A.; Lusk, B.; Malik Naanaa, A.; et al. The use of lateral flow immunoassays for the detection of fentanyl in seized drug samples and postmortem urine. J. Forensic Sci. 2021, 66, 758–765. [Google Scholar] [CrossRef] [PubMed]
  249. Angelini, D.J.; Biggs, T.D.; Prugh, A.M.; Smith, J.A.; Hanburger, J.A.; Llano, B.; Avelar, R.; Ellis, A.; Lusk, B.; Naanaa, A.; et al. Detection of fentanyl and derivatives using a lateral flow immunoassay. Forensic Chem. 2021, 23, 100309. [Google Scholar] [CrossRef]
  250. Guteneva, N.V.; Znoyko, S.L.; Orlov, A.V.; Nikitin, M.P.; Nikitin, P.I. Rapid lateral flow assays based on the quantification of magnetic nanoparticle labels for multiplexed immunodetection of small molecules: Application to the determination of drugs of abuse. Microchim. Acta 2019, 186, 62. [Google Scholar] [CrossRef]
  251. Thapa, D.; Samadi, N.; Patel, N.; Tabatabaei, N. Thermographic detection and quantification of THC in oral fluid at unprecedented low concentrations. Biomed. Opt. Express 2020, 24, 2178–2190. [Google Scholar] [CrossRef]
  252. Chand, R.; Mittal, N.; Srinivasan, S.; Rajabzadeh, A.R. Upconverting nanoparticle clustering based rapid quantitative detection of tetrahydrocannabinol (THC) on lateral-flow immunoassay. Analyst 2021, 146, 574–580. [Google Scholar] [CrossRef]
  253. Samadi, N.; Thapa, D.; Salimi, M.; Parkhimchyk, A.; Tabatabaei, N. Low-Cost Active Thermography using Cellphone Infrared Cameras: From Early Detection of Dental Caries to Quantification of THC in Oral Fluid. Sci. Rep. 2020, 10, 7857. [Google Scholar] [CrossRef]
  254. Ciesielski, A.L.; Wagner, J.R.; Alexander-Scott, M.; Smith, J.; Snawder, J. Surface Contamination Generated by “One-Pot” Methamphetamine Production. ACS Chem. Health Saf. 2021, 28, 49–54. [Google Scholar] [CrossRef]
  255. Kishbaugh, J.M.; Cielski, S.; Fotusky, A.; Lighthart, S.; Maguire, K.; Quarino, L.; Conte, J. Detection of prostate specific antigen and salivary amylase in vaginal swabs using SERATEC® immunochromatographic assays. Forensic Sci. Int. 2019, 304, 109899. [Google Scholar] [CrossRef]
  256. Murahashi, M.; Makinodan, M.; Yui, M.; Hibi, T.; Kobayashi, M. Immunochromatographic detection of human hemoglobin from deteriorated bloodstains due to methamphetamine contamination, aging, and heating. Anal. Bioanal. Chem. 2020, 412, 5799–5809. [Google Scholar] [CrossRef] [PubMed]
  257. Nuntawong, P.; Ochi, A.; Chaingam, J.; Tanaka, H.; Sakamoto, S.; Morimoto, S. The colloidal gold nanoparticle-based lateral flow immunoassay for fast and simple detection of plant-derived doping agent, higenamine. Drug Test. Anal. 2021, 13, 762–769. [Google Scholar] [CrossRef]
  258. Šuláková, A.; Fojtíková, L.; Holubová, B.; Bártová, K.; Lapčík, O.; Kuchař, M. Two immunoassays for the detection of 2C-B and related hallucinogenic phenethylamines. J. Pharmacol. Toxicol. Methods 2019, 95, 36–46. [Google Scholar] [CrossRef]
  259. Zeng, L.; Guo, L.; Wang, Z.; Xu, X.; Song, S.; Xu, L.; Kuang, H.; Li, A.; Xu, C. Immunoassays for the rapid detection of pantothenic acid in pharmaceutical and food products. Food Chem. 2021, 348, 129114. [Google Scholar] [CrossRef] [PubMed]
  260. Zhang, B.; Nan, T.-G.; Xin, J.; Zhan, Z.-L.; Kang, L.-P.; Yuan, Y.; Wang, B.-M.; Huang, L.-Q. Development of a colloidal gold-based lateral flow dipstick immunoassay for rapid detection of chlorogenic acid and luteoloside in flos Lonicerae japonicae. J. Pharm. Biomed. Anal 2019, 170, 83–88. [Google Scholar] [CrossRef]
  261. Wang, M.; Guo, L.; Yu, M.; Zhao, H. The application of a lateral flow immunographic assay to rapidly test for dexamethasone in commercial facial masks. Anal. Bioanal. Chem. 2019, 411, 5703–5710. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  262. Ning, X.; Tan, G.; Chen, X.; Wang, M.; Wang, B.; Cui, L. Development of a lateral flow dipstick for simultaneous and semi-quantitative analysis of dihydroartemisinin and piperaquine in an artemisinin combination therapy. Drug Test. Anal. 2019, 11, 1444–1452. [Google Scholar] [CrossRef]
  263. Kitisripanya, T.; Sermpradit, W.; Sakamoto, S.; Tanaka, H.; Putalun, W. An estimated quantitative lateral flow immunoassay for determination of artesunate using monoclonal antibody. Biomed. Chromatogr. 2020, 34, e4718. [Google Scholar] [CrossRef]
  264. Qian, J.; He, Q.; Liu, L.; Wang, M.; Wang, B.; Cui, L. Rapid quantification of artemisinin derivatives in antimalarial drugs with dipstick immunoassays. J. Pharm. Biomed. Anal. 2020, 191, 113605. [Google Scholar] [CrossRef]
  265. Novikova, A.S.; Ponomaryova, T.S.; Goryacheva, I.Y. Fluorescent AgInS/ZnS quantum dots microplate and lateral flow immunoassays for folic acid determination in juice samples. Microchim. Acta 2020, 187, 427. [Google Scholar] [CrossRef]
  266. Achilihu, H.; Feng, J.; Wang, L.; Bernert, J.Y. Tobacco Use Classification by Inexpensive Urinary Cotinine Immunoassay Test Strips. J. Anal. Toxicol. 2019, 43, 149–153. [Google Scholar] [CrossRef]
  267. Calabria, D.; Calabretta, M.M.; Zangheri, M.; Marchegiani, E.; Trozzi, I.; Guardigli, M.; Michelini, E.; Di Nardo, F.; Anfossi, L.; Baggiani, C.; et al. Recent Advancements in Enzyme-Based Lateral Flow Immunoassays. Sensors 2021, 21, 3358. [Google Scholar] [CrossRef]
  268. Zangheri, M.; Cevenini, L.; Anfossi, L.; Baggiani, C.; Simoni, P.; Di Nardo, F.; Roda, A. A simple and compact smartphone accessory for quantitative chemiluminescence-based lateral flow immunoassay for salivary cortisol detection. Biosens. Bioelectron. 2015, 64, 63–68. [Google Scholar] [CrossRef]
  269. Rong, Z.; Wang, Q.; Sun, N.; Jia, X.; Wang, K.; Xiao, R.; Wang, S. Smartphone-based fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of Zika virus nonstructural protein 1. Anal. Chim. Acta 2019, 1055, 140–147. [Google Scholar] [CrossRef]
  270. Rajendran, V.K.; Bakthavathsalam, P.; Bergquist, P.L.; Sunna, A. Smartphone detection of antibiotic resistance using convective PCR and a lateral flow assay. Sens. Actuators B Chem. 2019, 298, 126849. [Google Scholar] [CrossRef]
  271. Hou, Y.; Wang, K.; Xiao, K.; Qin, W.; Lu, W.; Tao, W.; Cui, D. Smartphone-based dual-modality imaging system for quantita-tive detection of color or fluorescent lateral flow immunochromatographic strips. Nanoscale Res. Lett. 2017, 12, 1–13. [Google Scholar] [CrossRef]
  272. Jung, Y.; Heo, Y.; Lee, J.J.; Deering, A.; Bae, E. Smartphone-based lateral flow imaging system for detection of food-borne bacteria E.coli O157:H7. J. Microbiol. Methods 2020, 168, 105800. [Google Scholar] [CrossRef]
  273. Liu, Z.; Hua, Q.; Wang, J.; Liang, Z.; Li, J.; Wu, J.; Shen, X.; Lei, H.; Li, X. A smartphone-based dual detection mode device integrated with two lateral flow immunoassays for multiplex mycotoxins in cereals. Biosens. Bioelectron. 2020, 158, 112178. [Google Scholar] [CrossRef]
  274. Wu, Z.; Lu, J.; Fu, Q.; Sheng, L.; Liu, B.; Wang, C.; Li, C.; Li, T. A smartphone-based enzyme-linked immunochromatographic sensor for rapid quantitative detection of carcinoembryonic antigen. Sens. Actuators B Chem. 2021, 329, 129163. [Google Scholar] [CrossRef]
  275. Zangheri, M.; Di Nardo, F.; Calabria, D.; Marchegiani, E.; Anfossi, L.; Guardigli, M.; Mirasoli, M.; Baggiani, C.; Roda, A. Smartphone biosensor for point-of-need chemiluminescence detection of ochratoxin A in wine and coffee. Anal. Chim. Acta 2021, 1163, 338515. [Google Scholar] [CrossRef]
  276. Lingervelder, D.; Koffijberg, H.; Kusters, R.; Ijzerman, M.J. Point-of-care testing in primary care: A systematic review on implementation aspects addressed in test evaluations. Int. J. Clin. Pract. 2019, 73, e13392. [Google Scholar] [CrossRef] [Green Version]
  277. Lattanzio, V.M.T.; von Holst, C.; Visconti, A. Experimental design for in-house validation of a screening immunoassay kit. The case of a multiplex dipstick for Fusarium mycotoxins in cereals. Anal. Bioanal. Chem. 2013, 405, 7773–7782. [Google Scholar] [CrossRef] [PubMed]
  278. Lattanzio, V.M.T.; Ciasca, B.; Powers, S.; von Holst, C. Validation of screening methods according to Regulation 519/2014/EU. Determination of deoxynivalenol in wheat by lateral flow immunoassay: A case study. Trends Anal. Chem. 2016, 76, 137–144. [Google Scholar] [CrossRef]
  279. Lattanzio, V.M.T.; Guarducci, N.; Powers, S.; Ciasca, B.; Pascale, M.; von Holst, C. Validation of a lateral flow immunoassay for the rapid determination of aflatoxins in maize by solvent free extraction. Anal. Methods 2018, 10, 123–130. [Google Scholar] [CrossRef]
  280. Lattanzio, V.M.T.; von Holst, C.; Lippolis, V.; De Girolamo, A.; Logrieco, A.F.; Mol, H.G.J.; Pascale, M. Evaluation of Mycotoxin Screening Tests in a Verification Study Involving First Time Users. Toxins 2019, 11, 129. [Google Scholar] [CrossRef] [Green Version]
  281. Pecorelli, I.; Guarducci, N.; von Holst, C.; Bibi, R.; Pascale, M.; Ciasca, B.; Logrieco, A.F.; Lattanzio, V.M.T. Critical Comparison of Analytical Performances of Two Immunoassay Methods for Rapid Detection of AflatoxinM1 in Milk. Toxins 2020, 12, 270. [Google Scholar] [CrossRef]
  282. Offermann, N.; Conrad, K.; Fritzler, M.J.; Fooke Achterrath, M. Development and validation of a lateral flow assay (LFA) for the determination of IgG-antibodies to Pr3 (cANCA) and MPO (pANCA). J. Immunol. Methods 2014, 403, 1–6. [Google Scholar] [PubMed]
  283. Di Nardo, F.; Anfossi, L.; Ozella, L.; Saccani, A.; Giovannoli, C.; Spano, G.; Baggiani, C. Validation of a qualitative immunochromatographic test for the noninvasive assessment of stress in dogs. J. Chromatogr. B 2016, 1028, 192–198. [Google Scholar] [CrossRef] [PubMed]
  284. Bheemavarapu, L.P.; Shah, M.I.; Joseph, J.; Sivaprakasam, M. IQVision: An Image-Based Evaluation Tool for Quantitative Lateral Flow Immunoassay Kits. Biosensors 2021, 11, 211. [Google Scholar] [CrossRef]
  285. Born, P.; Thran, S. The influence of CLIA ‘88 on physician office laboratories. J. Fam. Pract. 1998, 46, 319–327. [Google Scholar] [PubMed]
  286. Regulation (EU) 2017/746 of the European Parliament and of the Council of 5 April 2017 on In Vitro Diagnostic Medical Devices and Repealing Directive 98/79/EC and Commission Decision 2010/227/EU. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX:32017R0746 (accessed on 27 July 2021).
  287. Carter, D.J.; Cary, R.B. Lateral flow microarrays: A novel platform for rapid nucleic acid detection based on miniaturized lateral flow chromatography. Nucleic Acids Res. 2007, 35, e74. [Google Scholar] [CrossRef] [Green Version]
  288. Taranova, N.A.; Byzova, N.A.; Zaiko, V.V.; Starovoitova, T.A.; Vengerov, Y.Y.; Zherdev, A.V.; Dzantiev, B.B. Integration of lateral flow and microarray technologies for multiplex immunoassay: Application to the determination of drugs of abuse. Microchim. Acta 2013, 180, 1165–1172. [Google Scholar] [CrossRef]
  289. Safenkova, I.V.; Pankratova, G.K.; Zaitsev, I.A.; Varitsev, Y.A.; Vengerov, Y.Y.; Zherdev, A.V.; Dzantiev, B.B. Multiarray on a test strip (MATS): Rapid multiplex immunodetection of priority potato pathogens. Anal. Bioanal. Chem. 2016, 408, 6009–6017. [Google Scholar] [CrossRef]
  290. Zhang, D.; Huang, L.; Liu, B.; Ge, Q.; Dong, J.; Zhao, X. Rapid and Ultrasensitive Quantification of Multiplex Respiratory Tract Infection Pathogen via Lateral Flow Microarray based on SERS Nanotags. Theranostics 2019, 9, 4849–4859. [Google Scholar] [CrossRef]
  291. Natarajan, S.; Jayaraj, J.; Prazeres, D.M.F. A Cellulose Paper-Based Fluorescent Lateral Flow Immunoassay for the Quantitative Detection of Cardiac Troponin I. Biosensors 2021, 11, 49. [Google Scholar] [CrossRef]
  292. Jiang, X.; Lillehoj, P.B. Lateral flow immunochromatographic assay on a single piece of paper. Analyst 2021, 146, 1084–1090. [Google Scholar] [CrossRef]
  293. Yang, J.M.; Kim, K.R.; Jeon, S.; Cha, H.J.; Kim, C.S. A sensitive paper-based lateral flow immunoassay platform using engineered cellulose-binding protein linker fused with antibody-binding domains. Sens. Actuators B Chem. 2021, 329, 129099. [Google Scholar] [CrossRef]
  294. Elter, A.; Bock, T.; Spiehl, D.; Russo, G.; Hinz, S.C.; Bitsch, S.; Baum, E.; Langhans, M.; Meckel, T.; Dörsam, E.; et al. Carbohydrate binding module-fused antibodies improve the performance of cellulose-based lateral flow immunoassays. Sci. Rep. 2021, 11, 7880. [Google Scholar] [CrossRef] [PubMed]
  295. Zhang, J.J.Y.; Lee, K.S.; Ong, C.W.; Chan, M.Y.; Ang, L.W.; Leo, Y.S.; Chen, M.I.-C.; Lye, D.C.B.; Young, B.E. Diagnostic performance of COVID-19 serological assays during early infection: A systematic review and meta-analysis of 11 516 samples. Influenza Other Respir Viruses 2021, 15, 529–538. [Google Scholar] [CrossRef]
  296. Eftekhari, A.; Alipour, M.; Chodari, L.; Maleki Dizaj, S.; Ardalan, M.; Samiei, M.; Sharifi, S.; Zununi Vahed, S.; Huseynova, I.; Khalilov, R.; et al. A Comprehensive Review of Detection Methods for SARS-CoV-2. Microorganisms 2021, 9, 232. [Google Scholar] [CrossRef] [PubMed]
  297. Advice on the Use of Point-Of-Care Immunodiagnostic Tests for COVID-19. WHO Reference Number: WHO/2019-nCoV/Sci_Brief/POC_immunodiagnostics/2020.1. Available online: https://www.who.int/publications/i/item/advice-on-the-use-of-point-of-care-immunodiagnostic-tests-for-covid-19-scientific-brief (accessed on 27 July 2021).
  298. European Centre for Disease Prevention and Control. Options for the Use of Rapid Antigen Tests for COVID-19 in the EU/EEA and the UK. 19 November 2020. ECDC: Stockholm; 2020. Available online: https://www.ecdc.europa.eu/sites/default/files/documents/Options-use-of-rapid-antigen-tests-for-COVID-19_0.pdf (accessed on 27 July 2021).
  299. Scohy, A.; Anantharajah, A.; Bodéus, M.; Kabamba-Mukadi, B.; Verroken, A.; Rodriguez-Villalobos, H. Low performance of rapid antigen detection test as frontline testing for COVID-19 diagnosis. J. Clin. Virol. 2020, 129, 104455. [Google Scholar] [CrossRef]
Figure 1. SWOT analysis of the LFIA technique considering its inherent features.
Figure 1. SWOT analysis of the LFIA technique considering its inherent features.
Sensors 21 05185 g001
Figure 2. The structure of a typical LFIA strip. (a) backing support, (b) nitrocellulose porous membrane (c) sample pad, (d) absorbent pad, (e) conjugate pad, (f,g) immunoreagents areas, (h) labelled immunoreagent, (i,j) cassette, (k) reading window, (l) sample well, (mo) pressure points.
Figure 2. The structure of a typical LFIA strip. (a) backing support, (b) nitrocellulose porous membrane (c) sample pad, (d) absorbent pad, (e) conjugate pad, (f,g) immunoreagents areas, (h) labelled immunoreagent, (i,j) cassette, (k) reading window, (l) sample well, (mo) pressure points.
Sensors 21 05185 g002
Figure 3. Run of the assay: execution of the test and progression in time. Visually the appearance after the addition of the sample in the sample well changes in intensity until the complete appearance of the reacting bands.
Figure 3. Run of the assay: execution of the test and progression in time. Visually the appearance after the addition of the sample in the sample well changes in intensity until the complete appearance of the reacting bands.
Sensors 21 05185 g003
Figure 4. Number of publications per year for different classes of LFIA application from 2010 to 2019.
Figure 4. Number of publications per year for different classes of LFIA application from 2010 to 2019.
Sensors 21 05185 g004
Figure 5. Overview of (a) LFIAs and (b) multiplex LFIAs application fields in the period from 2010 to 2019.
Figure 5. Overview of (a) LFIAs and (b) multiplex LFIAs application fields in the period from 2010 to 2019.
Sensors 21 05185 g005
Figure 6. Overview of LFIA detection methods in the period from 2010 to 2019.
Figure 6. Overview of LFIA detection methods in the period from 2010 to 2019.
Sensors 21 05185 g006
Figure 7. Overview of LFIA labels used in colorimetric detection in the period from 2010 to 2019.
Figure 7. Overview of LFIA labels used in colorimetric detection in the period from 2010 to 2019.
Sensors 21 05185 g007
Table 1. Overview of the most recent and hot LFIA applications in the clinical field.
Table 1. Overview of the most recent and hot LFIA applications in the clinical field.
Application FieldTargetMatrixReference
ClinicalViruses and related infectionsEbola virusWhole blood, plasma[85,86,87]
HIV-1 and -2Blood, serum[84,88]
NorovirusesStool[89]
Influenza A/BNasopharyngeal (nasal) swab[90]
Chikungunya virusSerum[91]
Dengue virusBlood[92]
Herpes simplex virus type 2Plasma, serum[93]
SARS-CoV-2Serum, blood, saliva[94,95,96,97,98,99,100]
Bacteria and related infectionsBrucellosisSerum, plasma, whole blood[101]
Helicobacter pyloriStool[102]
Pneumococcal pneumoniaPleural fluid[103]
Plasmodium falciparum infectionsWhole blood[104]
Scrub typhusSerum[105]
Other infectious diseasesBurkholderia pseudomallei infectionsBlood, urine, other bodily fluids[106]
Pneumocystis pneumoniaSerum[107]
StrongyloidiasisSerum[108,109]
CandidiasisPharyngeal swabs[110]
Progressive disseminated histoplasmosisSerum[111]
ToxoplasmosisSerum[112]
Allergic bronchopulmonary aspergillosisSerum[113,114]
FascioliasisSerum[115]
Chagas diseaseSerum[116]
Cerebral angiostrongyliasisSerum[117]
Other diseasesSystemic lupus erythematosusSerum[118]
SepsisSerum[119]
Acute hyperglycemia and diabetes mellitusSerum[120,121]
Diabetic retinopathyUrine[122]
Alpha thalassaemiaWhole blood[123]
Kidney injuryUrine[124]
CancersGastricPlasma[125]
CervicalUrine[126]
OvarianSerum[127]
BladderUrine[128]
ProstateUrine[129]
Health status (bio)markersFolateSerum[130]
HormonesSaliva, urine, serum[131,132,133,134,135,136]
Cardiac biomarkerSerum, finger-prick blood[137,138,139]
FerritinSerum[140]
Myoglobin
Therapeutic drug monitoringTenofovirUrine[141,142]
Table 2. Overview of the most recent and hot LFIA applications in the food safety field.
Table 2. Overview of the most recent and hot LFIA applications in the food safety field.
Application FieldTargetMatrixReference
Food safetyToxinsBotulinum neurotoxin type A and Staphylococcal enterotoxin B Milk, grape juice[143]
Staphylococcal enterotoxin BMilk, honey[144]
TetrodotoxinCrucian, clam[145]
AmatoxinsMushrooms[146]
MycotoxinsAflatoxin B1 and fumonisinsMaize flour[82]
ZearalenoneMaize, cereals[147,148]
T-2 toxinTap water[149]
Aflatoxin B1, zearalenone and deoxynivalenolFeedstuff[150]
Fumonisin B1 and deoxynivalenolGrain[151]
AntimicrobialsTylosin and tilmicosinMilk, pork[152]
SulfamethazineEgg, honey, pork[153]
BacitracinMilk[154]
DiclazurilChicken[155]
LincomycinMilk, eggs, honey[156]
Carbadox and CyadoxChicken breast[157]
Bacitracin zincMilk[158]
Lincomycin and tylosinMilk, eggs, honey[159]
β-lactamsMilk[160]
ImidocarbMilk, beef[161]
Colistin and bacitracinMilk[162]
BacteriaStaphylococcus aureusOrange juice, lettuce salad, fish[163]
Escherichia coli O157:H7Milk, beef, pork, chicken, bread, jelly[164,165]
Salmonella spp.Chicken, eggs[166,167]
Campylobacter jejuniMilk, chicken[168]
Vibrio parahaemolyticusClam, white clam, flower clam, razor lam, yellow croaker, fresh shrimp[169]
AllergensMilk casein, egg chicken albumin, hazelnut proteinBakery products[170]
TropomyosinVarious food products[171]
Casein and β-lactoglobulinSeveral food matrices[172]
Major peanut allergenPeanut oils[173]
ParvalbuminFish[174]
GlutenGrain flours, food dough, burger patty, ice cream, soup[175,176]
β-conglycininSkimmed milk[177]
HormonesDexamethasoneMilk, pork meat[178]
17β-estradiolChicken, fish, prawn, pork[179]
Diethylstilbestrol and estradiolMilk, shrimp tissue[105]
PesticidesTriazophosCucumber[180]
Spirotetramat and spirotetramat-enolWine, grape juice, and grapes.[181]
Adulterants/food identification/illegal additivesMelamineMilk, animal feed;[182,183]
Specific buffalo’s milk proteinCow’s milk[184]
Saffron genomic DNADried herbal materials[185]
Duck meatBeef meat[186]
Horse and donkey meatSeveral foods[187]
Horse, pork beef, sheep meatFresh meat[188]
Pork meatSeveral meats[189]
Goose meatRaw, cooked food products[190]
Chicken meatMeat products[191]
Horse meatRaw, processed meat products[192]
SibutramineDiet food[193]
ChlorpheniramineHerbal teas[194]
Table 3. Overview of the most recent and hot LFIA applications in the veterinary field.
Table 3. Overview of the most recent and hot LFIA applications in the veterinary field.
Application FieldTargetMatrixReference
VeterinaryViruses and related infectionsAfrican swine feverBlood, spleen, tissue[195,196]
RabiesBrain tissue[197,198]
Porcine epidemic diarrheaColostrum, stool[199,200]
Bovine rotavirusStool[201]
Avian leukosis virusChicken meconium[202]
Avian infectious bronchitis virusChicken throat and cloacal swab[203]
Newcastle diseaseChicken serum[204]
Foot-and-mouth diseaseSerum, several tissue samples[205,206]
Canine adenovirusCanine serum, rectal swabs[207]
BrucellosisSerum[208]
Gumboro diseasePoultry[209]
Bacteria and related infectionsBovine mastitisMilk[210,211,212]
Mycobacterium bovis infectionBovine serum, whole blood; wild boar serum [213,214]
BrucellosisDromedary camels serum[215]
Other infectious diseasesBovine babesiosisBlood[216,217]
TrypanosomosisEquine serum[218]
FasciolosisSheep serum[219]
Canine visceral leishmaniasisSerum[220,221]
ToxoplasmosisCat serum[222]
Health status (bio)markersAmyloid AHorses’ serum[223]
ProgesteroneCattle plasma[224]
Table 4. Overview of the most recent and hot LFIA applications in the environmental field.
Table 4. Overview of the most recent and hot LFIA applications in the environmental field.
Application FieldTargetMatrixReference
EnvironmentalPesticidesCarbofuran and 3-hydroxy-carbofuranWater[225]
ParaquatWater[226]
Atrazine and acetochlorWater[227]
Acetochlor and fenpropathrinTap water[228]
PathogensE. coli O157:H7River water[229]
Human adenovirusWastewater[230]
Yersinia pestisSuspicious white powders, aerosol samples[231]
Heavy metalsLead (II)Drinking water[232]
Other pollutantsFree chlorineAqueous soluions[233]
Karenia mikimotoiMarine water[234]
Karlodinium veneficumSeawater[235]
Microcystin-LR toxinWater and fish[236]
Aflatoxin B1Potable water[237]
Bisphenol ASnow[238]
NorfloxacinTap and river water[239]
3-phenoxybenzoic acidLake water[240]
Table 5. Overview of the most recent and hot LFIA applications in other application fields.
Table 5. Overview of the most recent and hot LFIA applications in other application fields.
Application FieldTargetMatrixReference
OtherAgricultureBanana bract mosaic virusBanana leaf tissues[241]
Citrus tristeza virusCitrus leaves[242]
MetalaxylTobacco leaves[243]
Erwinia amylovoraDifferent plant parts[244]
Potato spindle tuber viroidPlant leanves[245]
Dickeya solaniPotato tubers[246]
ForensicFentanylHuman urine and serum[247,248,249]
Morphine, fentanyl and methamphetamineHuman urine[250]
TetrahydrocannabinolHuman oral fluids [251,252,253]
MethamphetamineSurface[254]
Prostate specific antigen and salivary amylaseVaginal swab[255]
Human hemoglobinBloodstain[256]
HigenaminePlant samples[257]
Hallucinogenic phenethylaminesHuman Urine[258]
IndustrialPantothenic acidPharmaceutical, food products[259]
Chlorogenic acid and luteolosideFlos Lonicerae Japonicae[260]
DexamethasoneCommercial facial masks[261]
Dihydroartemisinin and piperaquineCommercial artemisinin-based combination therapy drugs[262]
ArtesunatePharmaceutical formulation[263]
Artemisinin derivativesAntimalarial drugs[264]
Folic acidOrange, apple, banana, grape juice[265]
OtherCotinineHuman urine[266]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Di Nardo, F.; Chiarello, M.; Cavalera, S.; Baggiani, C.; Anfossi, L. Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives. Sensors 2021, 21, 5185. https://doi.org/10.3390/s21155185

AMA Style

Di Nardo F, Chiarello M, Cavalera S, Baggiani C, Anfossi L. Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives. Sensors. 2021; 21(15):5185. https://doi.org/10.3390/s21155185

Chicago/Turabian Style

Di Nardo, Fabio, Matteo Chiarello, Simone Cavalera, Claudio Baggiani, and Laura Anfossi. 2021. "Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives" Sensors 21, no. 15: 5185. https://doi.org/10.3390/s21155185

APA Style

Di Nardo, F., Chiarello, M., Cavalera, S., Baggiani, C., & Anfossi, L. (2021). Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives. Sensors, 21(15), 5185. https://doi.org/10.3390/s21155185

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop