Next Article in Journal
The Duality of Ray-Based and Pinhole-Camera Modeling and 3D Measurement Improvements Using the Ray-Based Model
Next Article in Special Issue
A Red-Emitting Fluorescence Sensor for Detecting Boronic Acid-Containing Agents in Cells
Previous Article in Journal
Trajectory Optimization in Terms of Energy and Performance of an Industrial Robot in the Manufacturing Industry
Previous Article in Special Issue
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives

by
Rabeay Y. A. Hassan
1,2
1
Applied Organic Chemistry Department, National Research Centre Dokki, Cairo 12622, Egypt
2
Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
Sensors 2022, 22(19), 7539; https://doi.org/10.3390/s22197539
Submission received: 30 August 2022 / Revised: 26 September 2022 / Accepted: 30 September 2022 / Published: 5 October 2022
(This article belongs to the Special Issue Advances in Optical, Fluorescent and Luminescent Biosensors)

Abstract

:
Modern life quality is strongly supported by the advances made in biosensors, which has been attributed to their crucial and viable contribution in point-of-care (POC) technology developments. POC devices are exploited for the fast tracing of disease progression, rapid analysis of water, and food quality assessment. Blood glucose meters, home pregnancy strips, and COVID-19 rapid tests all represent common examples of successful biosensors. Biosensors can provide great specificity due to the incorporation of selective bio-recognition elements and portability at significantly reduced costs. Electrochemical biosensor platforms are one of the most advantageous of these platforms because they offer many merits, such as being cheap, selective, specific, rapid, and portable. Furthermore, they can be incorporated into smartphones and various analytical approaches in order to increase their sensitivity and many other properties. As a very broad and interdisciplinary area of research and development, biosensors include all disciplines and backgrounds from materials science, chemistry, physics, medicine, microbiology/biology, and engineering. Accordingly, in this state-of-the-art article, historical background alongside the long journey of biosensing construction and development, starting from the Clark oxygen electrode until reaching highly advanced wearable stretchable biosensing devices, are discussed. Consequently, selected examples among the miscellaneous applications of nanobiosensors (such as microbial detection, cancer diagnosis, toxicity analysis, food quality-control assurance, point of care, and health prognosis) are described. Eventually, future perspectives for intelligent biosensor commercialization and exploitation in real-life that is going to be supported by machine learning and artificial intelligence (AI) are stated.

1. Fundamentals of Biosensors

In the past decades, the needs for developing chemical sensors and biosensors have rapidly increased due to severe environmental and health challenges. Conventional methods for chemical analysis offer many advantages, including their high accuracy and acceptable sensitivity. However, those analytical methods, in many cases, require complex instruments, high expensive reagents, large sample consumption, and lack of portability and cannot support on-site monitoring, and a lab specialist with high skills is required [1]. Hence, there is a need for developing chemical sensors and biosensors. Accordingly, Clark and Lyons have started the fast development of biosensors and their related aspects directly after introducing the primary glucose oxidase biosensor that was invented in 1962. Since then, many interesting sensor and biosensor applications have been described, and some of them have been commercialized. The simplest way to define a biosensor is: “an analytical device which includes a biologically active element or component in a close contact with an appropriate physicochemical transducer to generate measurable signal (optical, electrical, or electrochemical) directly proportional to the concentration of target substance(s)” [2].
Thus, biosensors are bendable detection techniques that have high importance, being able to resolve a potential number of problems and challenges in diverse areas like homeland safety, drugs and pharmaceutical analysis, environmental monitoring and food safety, explosives, and defense-related issues [3,4]. In terms of sampling conditions, biosensors can be directly used to examine the target analytes in a variety of complex samples without any prior sample pre-treatments [5]. Besides, the rapid and accurate recognition of simultaneous multi-targets with high selective identification, full-automation, and a reduction of costs and sample size could be obtained [6]. Herein, the most common known example in our daily life is the glucometer (blood glucose monitoring, displayed in Figure 1).
A biosensor consists of three main constituents: a bio-recognition element (which is also known as a bio-receptor or a bio-sensing element), a transducer, and a signal processor (a schematic diagram of the construction and the main building blocks comprising a typical biosensor is demonstrated in Figure 2). In the first compartment, a bio-receptor is designed and selected for the high specific identification of a selected analyte. Then, the transducer, which is linked directly to the bio-receptor, is converting the biological as well as the biochemical responses into a quantifiable signal. The invisible/small signal inputs from the transducer is eventually magnified to greater output signals that comprises the important waveform features of the input signals. Thus, a digital signal processor collects the magnified signals that can be displayed, analyzed, and saved into the device internal memory [6]. Such electronic components enable detecting, recording, and transmitting the obtained data. The main biosensor advantages (i.e., the high selectivity, as well as the high-sensitivity features) are critically regulated and influenced by the selection of a bio-receptor and a viable method to fix it onto a transducer surface [7]. In terms of performance factors, interaction(s) between the bio-recognition sites and the objective under sensing has to be resistance to the change in the pH of the measurement, temperature, and stirring conditions or to the addition of a foreigner species (i.e., non-targeting analyte). The bio-receptors should be capable of retaining their orientations, structures, functions, and biological activities during biosensor function. As a result, selecting an effective and correct technique for the immobilization of the sensing element is very crucial, and it is one of the keys controlling biosensors performance [8]. Otherwise, a deactivation, misorientation, or leaching out from the surface of the transducer would have occurred. In this regard, two common immobilization techniques are widely used including both chemical (covalent binding) and physical (adsorption or attachment) methods. According to the analyte properties alongside the type of bio-recognition element, the best-fitting immobilization method is then decided [7,9].
The development of novel biosensors is one of the recent trends taking place worldwide. Thus, biosensor research is expected to drive innovations in various fields including point-of-care (POC), wearable, implantable, and miniaturized biosensor devices. Thus, in this review article, the fundamentals and impact of nanomaterials on the structure and design of nanosensors and biosensors were demonstrated. In addition, future perspectives on the strong expected contribution of artificial intelligence (AI) and machine learning in data analysis and visualization applied to biosensing were discussed.
Figure 1. Glucose biosensors, the most common example of electrochemical biosensors, consists of a digital pocket (portable reader) and a sensor chip (a three-electrode setup represents a reference electrode, a counter, and a working electrode). The selective determination of glucose concentration in samples is catalyzed by the enzymatic function of glucose oxidase loaded onto the surface of the working surface [10,11].
Figure 1. Glucose biosensors, the most common example of electrochemical biosensors, consists of a digital pocket (portable reader) and a sensor chip (a three-electrode setup represents a reference electrode, a counter, and a working electrode). The selective determination of glucose concentration in samples is catalyzed by the enzymatic function of glucose oxidase loaded onto the surface of the working surface [10,11].
Sensors 22 07539 g001
Figure 2. A common diagram displaying the main biosensor’s building blocks including: (I) a bio-receptor, (II) a transducer, and (III) signal processor [12,13].
Figure 2. A common diagram displaying the main biosensor’s building blocks including: (I) a bio-receptor, (II) a transducer, and (III) signal processor [12,13].
Sensors 22 07539 g002

2. A Brief History of Biosensors

In the first generation, the biosensor measured the biproduct outcome of the analyte–bio-receptor reaction, which is diffused to the surface of the transducer to generate a quantifiable response. This type of sensor was also known as a mediator-less biosensor. In this regard, the biosensor’s father (Leland Charles Clark) defined the components of a biosensor-setup in his first report that was published in 1956 about the oxygen sensors for blood measurements [14]. In 1962, the first experimental trial for the amperometric detection of glucose using an enzymatic-based electrode was conducted by Clark and collaborators, described in [15]. Then, in 1967, Hicks and Updike modified Clark’s approach by introducing the first glucose oxidase-based electrode, and they implemented this biosensor as an oxygen sensor. Afterwards, in 1969, Guilbault and Montalvo constructed the first enzymatic-based potentiometric biosensor wherein they optimized the potentiometric assay to be applied for enzymatic urea determination [16,17]. Later, in 1973, further modification was carried out by Guilbault and Lubrano, who simultaneously measured both lactate and glucose by the enzymatic-based biosensor relying on the amperometric detection of hydrogen peroxide at a platinum disc-electrode [18]. In this sensor’s construction, the metallic surface of the working electrode was fully covered by a thin film of an immobilized active enzyme in order to provide the high signal stability. Subsequently, particularly in 1974, Klaus Mosbach’s research group created the first ”thermistor biosensor”, which is a heat-sensitive enzyme sensor [19]. Then, in 1975, an optical biosensor was designed by Lubbers and Opitz, who manipulated the concept of the enzymatic biosensor to be applied for the optical determination of alcohol [20]. A series of achievements in biosensor development has been made, and continuous improvement led to the birth of the second generation of biosensors. In the second generation, electron transfer mechanisms from the active center of the immobilized bio-receptors (mainly enzymes) to the conductive electrode surface was the main concern for several research groups. Therefore, individual components, such as artificial redox mediators (electron carriers or electron acceptors in the sensing systems) like menadione, ferricyanide, ferrocene, and 2,6-dichlorophenolindophenol (DCIP), were integrated to facilitate the electron transfer and to amplify the generated signal [21,22,23]. These new classes of biosensors were called mediator-biosensors, and they led to a definite analytical enhancement in the sensitivity and limit of detection aspects. Technically, the redox mediators could be implemented within the biological matrix (e.g., cross-linked with enzymes, antibodies, or bio-receptors), or they could be added freely (in a soluble form) into the measuring solutions. The first mediated-biosensors was practically introduced in 1976 by Clemens et al. when a “bedside artificial pancreas” was fabricated and provided as an electrochemical glucose biosensor [23]. Later in the same year (1976), another mediated-biosensor approach was reported for blood lactic acid determination using a lactate dehydrogenase-based biosensor. In that study, La Roche manufactured a fully automated lactate-monitor, which was used for mediating the electron transferring from the active metabolic substrate to the electrode surface [24].
The completion of the first and second generation of biosensors has led to exploring a third generation; the cost and feasibility of biosensing and portability were the main driving forces of the third generation of biosensors. Subsequently, Liedberg (1983) implemented the surface plasmon resonance (SPR) technique to define the reactions’ dependency in real-time monitoring [24]. Then Higgins et al. in 1984 invented a pen-sized amperometric detector that was sponsored by Cambridge, USA [25]. A new biosensor generation, the most recent one, was developed through the era of nanotechnology, wherein the powerful characteristics of nanomaterials were exploited in the fabrication of nano-sensors and nano-electronics [26]. Ultimately, from the Clark biosensing approach (the first sensor model) until now, great achievements and huge advancements have been made in biosensor progression.

3. Electrochemical-Based Biosensors

Electrochemical sensing and biosensing systems offer the superior capability of multiple analyte(s) detection in complex samples (such as serum and other clinical specimens), with high selectivity and sensitivity. In this sensing platform, bio/electrochemical events (mediated or non-mediated processes) are taking place at the interface of electrochemical transducer surface (working electrode surface). In addition, the selective binding affinity, alongside the catalytic activity between an analyte and a fixed or immobilized bio-receptor could be screened and determined since the generated electrochemical signals could be recorded. Potentiometric, amperometric, conductometric, impedimetric, and voltammetric techniques are the main electrochemical methods used for constructing, adjusting, and optimizing tremendous electrochemical sensors and biosensors [27]. A synopsis of each of these electrochemical techniques will be pointed out in further subsections.

3.1. Potentiometric Biosensors

A potentiometric biosensor is defined as an electrochemical device that integrates a biological sensing element with an electrochemical transducer (the working electrode) to generate a difference in the electrical potential [28]. To convert a certain biochemical activity into an electric potential signal, ion-sensitive field-effect transistors, or specific ion electrodes (which are also the so-called ion-selective electrodes (ISEs)) could be applied. Using a selective bio-receptor (e.g., peptides, aptamers, antibodies, or enzymes), adaptable potentiometric sensing protocols could be designed for a wide range of different target analytes. Recently, potentiometric nano-biosensors were developed for the rapid diagnosis of COVID-19 using a three-dimensional molecular imprinted polymer (MIP) [29]. Reflecting the high selectivity of this COVID-19-potentiometric biosensor, discrimination between the targeting coronavirus and other viruses including influenza virus (H1N1 and H3N2) and Middle-East respiratory syndrome (MERS) was achieved. Besides, the virus biosensors reached a very low limit of detection for both spike proteins and a pure suspension of viral particles, with 100 pg/mL and 200 PFU/mL, respectively.

3.2. Amperometric Biosensors

A three-electrode setup or two-electrode configuration could be applied for operating an amperometric technique. At a fixed voltage, referring to a reference electrode (e.g., Ag/AgCl or calomel), the sensor drives a faradaic current occasioned by any redox reaction(s) that might occur at the surface of the working electrode. The value of the generated redox current is dependent on the concentration of the analyte that is presented in a supporting electrolyte [30]. The working electrode could be made of or modified with nanomaterials such as carbon-based materials (e.g., graphite, graphene, or carbon nanotubes), noble metals (e.g., gold, platinum, copper), or metal oxide (indium tin oxide (ITO). Amperometric sensing techniques offer great advantages including a wide dynamic–linear response, high precision, fast reading, and high sensitivity. These listed features acquired by this electrochemical method qualified it for mass production and commercialization. Nevertheless, the weakness of selectivity represented by the high interferences and cross-reactivity with other electroactive substances is considered a huge disadvantage and drawback [31]. Recently, an amperometric biosensor was developed by Yaping Dong et. al. and used for the clinical evaluation of creatinine in renal function evaluation. As shown by Yaping’s group, the sensors exhibited promising applicability for on-site medical examination, as well as at-home testing [32].

3.3. Conductometric Biosensors

Conductometric biosensors can detect any electrochemical reactive change occuring in a solution. Thus, any change in the ionic composition of the tested sample due to chemical and biochemical reactions taking place could be determined [33]. The conductometric biosensors exhibited several advantages: (I) they do not need a reference electrode; (II) a thin-film electrode is appropriate for miniaturization and large-scale production using inexpensive materials; (III) conductometric transducers are not light-sensitive, and their power consumption is significantly low. Conductometric biosensors were developed using a thin-layer of Au, Cr, Cu, and Ni, which formed on the electrode surface. These modified electrodes were exploited for the immobilization of two active enzymes (glucose oxidase and urease) that were applied for the bio-catalytic oxidation of glucose and urea on the electrode surface [34].

3.4. Impedimetric Biosensors

Impedimetric biosensors, the most powerful electrochemical biosensing technique, record the electrical impedance created at the interface of a solid electrode surface when a small AC potential is applied, then the changes in resistances are measured as a function of frequency [35]. A simple demonstration to visualize what is going on in the EIS systems during the conducting of experiments and before generating the EIS signals is shown in Figure 3. The EIS representation is expressed as an imaginary impedance (Zimag) plotted on the Y-axis, and a real impedance (Zreal) plotted on the X-axis to form the Nyquist plot, an example of which is shown in Figure 4. Each point on the Nyquist [lot is the impedance at one frequency point, while the Zimag (the imaginary impedance) is expressed in negative values. On the X-axis, the right side of the plot is positioned at the low frequency data and higher frequencies are allocated on the left. Among the electrochemical biosensors, EIS is a very sensitive technique for the investigation of interfacial properties that could be conducted at the functionalized surfaces. Therefore, bio-recognition events such as the antigen–antibody capture, protein–protein interaction, drug–target interaction, or whole microbial cell activity could be kinetically monitored. Several impedimetric biosensors were designed using antibodies or aptamers to fabricate impedimetric-immunosensor or impedimetric-aptasensors, respectively [36,37]. In the impedimetric-immunosensor, antigen–antibody specific immune-interaction(s) enable the formation of an immune-complex at the sensor surface that is the point of EIS measurements. On the other hand, the impedimetric-aptasensor represents the immobilization of short single-stranded oligonucleotides, which are so-called aptamers (e.g., RNA or DNA) with high stability and strong binding affinity [38]. Because of that, electron transfer/charge transfer resistance increases. Thus, the EIS-biosensors enable the label-free detection of biomolecular-recognition actions [39]. The use of EIS systems in biomedical and environmental analysis is increasing due to their readiness for lab-on-a-chip fabrication with facile manipulation and the capability to conduct onsite determination [40,41]. On the other hand, EIS is a non-destructive technique that is not limited to biosensor applications but can be exploited to characterize new materials by providing electrochemical information about the ongoing processes such fuel cell electrochemical performance, the formation or inhibition of corrosion, the charging/discharging of batteries, or any other electrochemical process [42,43].

3.5. Voltammetric Biosensors

Voltammetric biosensors analyze the target concentration by determining the generated faradaic current through the variation in the electric potential. The advantages of these sensors include the possibility of measuring multiple analytes (simultaneous analysis) [45]. The voltammetry measures both the variable electrical potential (X-axis) and electric current (Y-axis). Because of the oxidation or reduction of electroactive analyte at the working electrode surface, the peak position at a certain potential value will be used for identification (analyte character cathodic/anodic peak potentials), while the concentration of the corresponding species is reflected by the intensity of the peak current (Faradic current). Among different types of voltammetric techniques, cyclic voltammetry (CV) is the most common one for obtaining quantitative, as well as qualitative, data. Extensive information on the kinetics of electron transfer, the thermodynamics of redox reactions, and the rate of diffusion, as well as the rate of adsorption processes, could be obtained from the CV data. Various voltammetric biosensors for heavy metals (e.g., Pb(II), Cr(VI) and Cd(II), and Hg(II)) determination in environmental samples [46,47,48,49], glucose and urea monitoring in blood using disposable sensor chips [50,51], pharmaceutical compounds in plasma and dosage forms [52], and pathogen biomarkers in microbial cultures using macromolecules such as crown-ethers [46]) have been reported and discussed.

4. Impact of Nanomaterials on Biosensor Performance

To construct an effective and high-performance electrochemical sensor and biosensor, working electrode materials must satisfy certain criteria such as biocompatibility, high electrical conductivity, catalytic activity, eco-friendly, and low cost. Moreover, electrode materials have a significant influence on the thermodynamics, as well as the kinetics redox reactions (e.g the electron transfer taking place at the interfaces), and thus they frequently define and support the success of electrochemical processes.
The most commonly used working electrode materials are metallic electrodes (platinum, silver, gold), carbon-based electrodes (e.g., glassy carbon electrode (GCE), carbon paste electrode (CPE) [53], and graphite electrode (GE)). Mercury electrodes (such as a dropping mercury electrode (DME) and a hanging mercury drop electrode (HMDE)) have been conventionally used in polarography [54]. Figure 5 collected the most common working electrodes starting from the DME, ending with the disposable screen-printed electrodes. The toxicity of mercury limited and forbade its uses, while the other electrodes showed some undesired features including their large sizes, which require large electrochemical cells and too much of the analyte, in addition to the difficulty with portability and disposability. Thus, such classical working electrodes are used for the lab investigations and material characterizations.
Nanomaterials (synthesis and applications) are strongly involved in tremendous applications including biomaterials, catalysis, nanobiosensors, and nano-bioelectronics [55]. The use of nanoparticles, nanotubes, nanowires, nano-pores, or any other nanostructures in biosensors and the fabrication of devices for diagnosis have been intensively explored [56,57]. Nanomaterials are used for the manufacturing of electrochemical transducers or the functionalization of solid surfaces. The engineered nanostructured materials, with a desirable bio-compatibility, offer an expandable surface-to-volume ratio due to their nanoscale size, and they provide high mechanical strength, electrical conductivity, and catalytic activity [58]. Therefore, they are used often to enhance biosensor performance, amplifying the electrochemical readouts, increasing the sensitivity, and providing a low limit of detection of several orders of magnitudes. In terms of the molecular orientation and structure stability of the immobilized bio-recognition elements, nanostructured-sensor platforms are excellent substrates to efficiently maintain the alignments and orientation while sustaining the bioactivity of the immobilized biomolecules. Moreover, direct charge/electron transfer is facilitated when certain nanomaterials are implemented [59]. For example, carbon nanomaterials have been utilized for the conjugation of biomolecules (DNA, antibody, enzyme, or whole cells) with electrochemical transducers [60]. According to their dimensions and sizes, nanomaterials are classified into four types, including zero dimension, one dimension, two dimensions, and three dimensions. In zero dimensions (0D), metallic nanoparticles (e.g., silver, gold, platinum, gold, and palladium) and quantum dots have all their three dimensions of materials exist in nanoscale. Nanoparticles can be spherical in size, with an average diameter of 1–50 nm. In one dimension (1D), only one dimension is in the range of 1–100 nm, and the other two dimensions can be in macroscale. Examples of 1D nanomaterials include nanowires, nanofibers, nanorods, and nanotubes. In two dimensions (2D), two dimensions are in nanoscale, and one dimension is in macroscale. Coating solid surfaces with nanomaterials creates 2D-like structures (e.g., nano-sheets, nano-walls, nano-thin-films, or nano-thin-multilayers) [61]. Keeping the thickness constant in the nanoscale range, the total area of nanomaterials’ 2D-like structures could be within some square micrometers. Regarding the 3D nanostructures, all dimensions are in the macro-scales, and there are no dimensions in nanoscales. Thus, the 3D nanostructures are bulk materials that contain individual components (blocks) in nanoscale (less than 100 nm). Optical and electrochemical nano-sensors are the most widely used detection modalities due to their simple operation and portability [62]. Examples of nanomaterials that have been frequently exploited in the fabrication and functionalization of nano-biosensors is denominated in Figure 6. A wide range of nanostructured materials has been extensively used as sensing platforms with an expandable surface area for better receptor–analyte interaction and for enhancing electrochemical signal outputs. Carbon nanomaterials, including carbon nanofibers, carbon nanotubes, graphene, or fullerene (C60), are perfect materials for sensor fabrication due to their advantages of high electrical conductivity, large surface area, easy functionalization, and their high biocompatibility. Metal and metal oxides nanostructures are predominant materials used for sensor modification because of their high electrocatalytic activity and their tendency to facilitate the electron transfer/charge directly in mediator-less biosensing systems. Thus, ZnO, CuO, NiO, TiO2, and Fe3O4 have been widely used in electrochemical biosensing to promote faster electron transfer kinetics between the electrode and the active sites of immobilized bio-receptors, which led to synergistic enhancement in sensing performance [13].
Precious metal nanostructures, including Au, Pt, Ag, and Pd, have been exploited for electrode modification due to their inertness against oxidation reactions and good biocompatible properties [63,64,65,66]. These nanostructures could be arranged on the electrode surface, or they could be mixed with other components (e.g., polymeric or sol-gel materials) in the electrode matrix [67]. Ultimately, based on the advantages of those unique properties of nanomaterials, nano-sensor devices allow the fabrication of nano-sensor chips and portable sensing devices for rapid and accurate multi-target in complex biological and environmental matrices.
Figure 6. Most commonly used nanomaterials, metal nanoclusters, or nanocomposites for the fabrication of electrochemical nano-biosensors (CNFs: carbon nanofiber, BNPs: bimetallic nanoparticles, GR: graphene, CNOs: carbon nano-onions, MNPs: magnetic nanoparticles, QDs: quantum dots, CNTs: carbon nanotubes, and NPs: nanoparticles). This Figure is adapted from Rizwan and Mohd-Naim et al. [68].
Figure 6. Most commonly used nanomaterials, metal nanoclusters, or nanocomposites for the fabrication of electrochemical nano-biosensors (CNFs: carbon nanofiber, BNPs: bimetallic nanoparticles, GR: graphene, CNOs: carbon nano-onions, MNPs: magnetic nanoparticles, QDs: quantum dots, CNTs: carbon nanotubes, and NPs: nanoparticles). This Figure is adapted from Rizwan and Mohd-Naim et al. [68].
Sensors 22 07539 g006

5. Biomedical and Environmental Applications

Electrochemical biosensors are widely exploited in miscellaneous applications such as microbial detection, cancer diagnosis, toxicity analysis, and food quality-control assurance, point of care, and health prognosis. In the next subsections, discussion and sorting examples of some of these applications will be handled.

5.1. Nano-Electrochemical Biosensors for Microbial Detection

Microbial infections have dramatically spread over the past few decades to be considered one of the most urgent global challenges. Delaying diagnosis might lead to death [69,70]. Thus, early detection (as much as possible) for virulence factors, pathogens, and biological toxins is very necessary to prevent the progression of infection and to provide effective treatments. Electrochemical immune-sensors are among the most common biosensing platforms for microbial detection and identification [71]. The signal is usually obtained through the immobilization of a bio-recognition element on the working electrode surface. The assay steps often end with the injection of a secondary enzyme-labeled antibody that follows the addition of a proper enzymatic substrate [72]. In addition to immunosensors, several methods were used to enhance the selectivity and sensitivity of the electrochemical biosensors. Molecularly imprinted polymers (MIPs)-based electrochemical biosensors are one of those methods. MIPs were created via chemical, photochemical, or electrochemical methods in the presence of a target template molecule(s). MIPs’ exploitation using completely microbial cells as a template have been reported for many applications, including microbial fuel, specific cell capture, cell sorting, separation, and microbial detection. MIP biosensors were also fabricated for the rapid capture and identification of Salmonella typhimurium in minced beef samples [73]. Using cyclic voltammetry, the assay optimization and validation have been achieved, reaching a high selectivity and sensitivity against the imprinted cells of S. typhimurium. Bacteriophages can serve as high-efficiency bio-receptors for the development of electrochemical biosensing platforms. Bacteriophage-sensing platforms have high specificity against their bacterial host [74,75]. In addition, in terms of thermal stability and sensitivity to the changes in surrounding pHs, or solvents, a bacteriophage-based biosensor is more preferable than the immunosensors [74]. In this regard, Mona Tolba and her team developed an impedimetric phage-based biosensors for the selective determination of Listeria innocua serovar [76]. As a biorecognition element for this sensor, the bacteriophage endolysin was chemically conjugated onto the screen-printed electrode surface via classical EDC/NHS chemistry. With their developed biosensors, Tolba’s team reached a limit of detection of 105 CFU and 104 CFU/mL, in 2% milk and in a pure culture, respectively. A collective summary of nano-electrochemical transducers’ involvements in the microbial sensors’ construction is displayed in Table 1.

5.2. Nano-Electrochemical Biosensors for Toxin Detection

As the microbial extracellular-secreted toxins (e.g., hemolysins, leukotoxins and enterotoxins) are the major causative agents of the poisoning and as these toxins may persist even after disinfection, their presence and biological activity have to be determined [100,101]. In this regard, the electrochemical determination of staphylococcal enterotoxin B (SEB) was achieved when Nodoushan and his team succeeded in developing a nanostructured aptasensor using a screen-printed electrode modified with reduced graphene-oxide–gold nanourchins. Differential pulse voltammetry (DPV) was used in the quantitative analysis of the selected enterotoxin, and a linear range from 5.0 to 500.0 fM was obtained with a calculated limit of detection of 0.21 fM [102]. Another electrochemical immnuo-biosensing approach for the determination of Staphylococcal enterotoxin B (SEB) was presented by Chatrathi and his coworkers [103]. A selective antibody was chemically immobilized onto the gold electrode surface through the chemical cross-linking with the amine- or sulfhydryl-reactive heterobifunctional cross-linker. The sensitivity of this immunosensor reached 1.0 ng/mL that corresponds to 5.0 pg in a 5 µL sample. Besides, a nanostructured electrochemical immune-biosensor was developed for the rapid identification of the staphylococcal enterotoxin B. Hence, the chemical conjugation of the selected antibody was conducted on the electrode surface, which is modified with rGO-chitosan-AuNPs. The developed biosensor exhibited high sensing performance due to the flat two-dimensional configuration and large surface area. A limit of detection of 5.0 ng/mL of the targeting SEB was obtained with a sensing time estimated by 35 min [104]. In general, nanomaterial-derived biosensors offer the rapid and sensitive detection of food toxins [105].
On the other hand, neurotoxicity is a major causative factor for Parkinson’s and Alzheimer’s diseases as the common neurodegenerative illnesses [106]. One major group of chemicals with neurotoxic effects is organophosphates (OPs). OPs are very toxic to humans and most animals due to the covalent inhibition of acetylcholinesterase (AChE), a key enzyme for the transmission of nervous signals, responsible for the removal of acetylcholine at the synaptic level [107]. Usually, electrochemical OP biosensors using AChE are based on the catalytic production of thiocholine (TCl), which is electro-active, from the substrate acetylthiocholine (ATCl) [108]. The presence of OPs would result in the inhibition of AChE, reducing thiocholine production, thus decreasing the electrochemical signal. However, new bio-receptors, more sensitive and stable, have been evaluated as an alternative to less-specific and less-stable AChE [109,110].

5.3. Nano-Electrochemical Biosensors for Cancer Diagnosis

There are wide varieties of biomarkers (peptides, proteins, antibodies, DNA, RNA, and microRNA) that could be employed as prognostic and predictive tools for the rapid detection of cancer. In the field of cancer biology, anti-proliferative/cytotoxic drug effectiveness and studying various emerging metastatic cancer aspects have been explored using various biosensor techniques [111]. Inspecting specific biological analytes (such as extracellular metabolites, nucleotides, expressed protein biomarkers, or whole cancer cells) is the power to operate electrochemical biosensors. To this end, various types of electrochemical biosensors including microfluidic assays, genosensors, impedance-based biosensors, electrochemluminescence biosensors, and immunosensors were developed. In a recent review article, an interesting integration between the classical cytochemical methods and bioelectrochemical and biophysical techniques (such as electrochemical impedance spectroscopy, cyclic voltammetry, electron microscopy, and atomic force microscopy, as shown in Figure 7) is suggested for the effective understanding of cancer metastasis and apoptosis [111].
Since Caspase-3 (Cas-3) is a crucial mediator in the extrinsic apoptosis signaling cascade, several electrochemical assays were developed for its rapid and sensitive detection [112,113,114]. The cellular microenvironment and cancer cell viability were investigated electrochemically using a 2D- and 3D-sensing cell culture flask integrated with an electrochemical station for recording the obtained electrochemical signals due to metabolic activity and/or extracellular changes. Nano-fabricated sensor chips are fixed on standard cell culture flasks to allow the electrochemical inspection of the cell activity during the cultivation and growth cycles [115]. Those systems have been applied for measuring the electrochemical behaviors of breast cancer cells, as well as brain tumor cells. Furthermore, cancer cellular respiration was measured using the amperometric oxygen sensor, whereas different incubation conditions were applied [116]. Moreover, electrodeposited iridium oxide films were implemented for sensing cellular acidification using a potentiometric pH sensor. The designed biosensing setup enabled an initiative for pursuing 3D-cell biosensor-based cell cultures [117]. An aptasensor was designed for the impedimetric biosensong of Cyt-c using silver nanocluster conjugation [118]. In another cancer biosensor report, an immunosensor was developed for the direct recognition of Bcl-2 and Bax in cancer cell cultures [119]. Further analysis for cancer biomarkers considered one of the anti-apoptotic biomarkers, named Survivin (Sur) [120], whereas a microchannel cyto-sensor was designed to selectively capture it using the anti-survivin oligonucleotide sensor [120]. Besides, a trans-membrane protein known as epithelial cell adhesion molecule (EpCAM) was electrochemically determined using an impedimetric immuno-based biosensor [121]. A colon-cancer-secreted biomarker (IL-13Rα2) has amperometrically been detected [122], whereas its in situ expression was analyzed either in the intact colon cancer or in the lysed cells. In another study, an aptasensor was constructed to recognize L-tryptophan (Trp) based on constant current–potentiometric striping analysis [123]. This Trp-aptasensor proved to be sensitive, with a limit of detection of 6.4 ×10−11 M. In another biosensor report, the metastasis of pancreatic tumor cells has been monitored via biosensing the expression of trypsin in cell lysate, which changes its level in cases of pancreatic cancer [124]. In a recent study, simultaneous analysis for metastatic biomarkers programmed death ligand-1 (PD-L-1) and hypoxia-inducible factor-1 alpha (HIF-1α) was developed and offered a detection limit value of 86 pg/mL [125].
To summarize the roles of electrochemical biosensors in cancer metastasis and apoptosis detection, the simple design of biosensing devices make them a reliable tool for the early detection of specific biological targets by converting a biological entity (cell viability, protein binding affinity, and DNA or RNA sensing) into an electrochemical signal that can be measured and analyzed. Besides, cancer biosensors have the ability to determine the real-time continuous responses of cancer or normal cells to discover potential anticancer agents. The future directions for cancer electrochemical sensors are directed towards the development of new functional polymeric substrates (biocompatible and flexible chips) for effective cell adhesion and proliferation or nanostructured biomaterials to be valid for nano-fabrication techniques.

5.4. Nano-Electrochemical Biosensors for Viral Infection Diagnosis

Biosensors have generated a great interest in monitoring infectious diseases, especially those caused by microbial pathogens, such as fungi, bacteria, and viruses. Molecularly imprinted polymers (MIPs) are reported to have promising biological applications due to their intrinsic binding affinity to specific proteins and other biological materials. Numerous researches addressed the use of MIPs for accurate viral diagnosis in real-time [126]. MIPs fabricated by Piletska et al. were applied for virus identification and the screening of different epitopes of Adeno-associated viruses (AAV) immobilized on glass beads using polymeric nanoparticles of acrylate and methacrylate [127]. On the other hand, a biosensor was fabricated for the viral hexon protein (the most accessible and abundant surface protein of the human adenovirus type 5 (hAdV5) icosahedral capsid). This biosensor was applied as the template molecule for the entire virus recognition. To validate the sensor’s selectivity, two different viruses, including hAdV5 and minute virus of mice (MVM) were exposed to the sensors with no obvious binding affinity [128].
The virus-neutralizing capacity of hydrogel-based MIPs were produced using a model mammalian virus (porcine reproductive and respiratory syndrome virus (PRRSV-1)) [129]. During the optimization procedure of this biosensor, specificity of virus neutralization, alongside the influence of incubation time on sensor performance, were studied. The sensor’s selectivity was assessed by comparing their neutralizing effects on PRRSV-1 to the effects on the unrelated bovine viral diarrhea virus-1. As a result, no significant cross-reactivity was detected. Thus, the MIPs demonstrated effective virus neutralization in just 2.5 min, and their effect was concentration-dependent. An impedimetric MIP-based sensor was constructed for the detection of dengue virus in the early stage of the infection in serum samples exploiting the self-polymerization of dopamine in the presence of target non-structural protein 1 (NS1), whereas the detection limit was 0.3 ng/mL [130]. A magnetic molecularly imprinted resonance light-scattering sensor was also created for the detection of Japanese encephalitis virus (JEV) within 20 min based on the polymerization of tetraethyl orthosilicate (TEOS), whereas a linear dynamic range of 0.02–2.0 nM was achieved with a limit of detection of 0.1 pM. The sensor’s recovery was evaluated to range from 88% to 107%, to support the determination of the virus in human serum samples [131]. Antibodies-conjugated polyaniline nanowires embedded in graphene quantum dots and nano-gold were used for the detection of hepatitis E virus (HEV) in clinical samples. Introducing an external electrical pulse during the HEV accumulation step enhanced the sensor sensitivity against the targeting virus due to the expansion of the sensor’s surface and the expanding antibody-conjugated polyaniline chain length. The sensor was then used to monitor various HEV genotypes, including G1, G3, G7, and ferret HEV obtained from a cell culture supernatant and in a series of fecal specimen samples collected from G7 HEV-infected monkeys [132]. Zika virus (ZIKV) rapid detection and identification were carried out by the development of electrochemical biosensors based on surface-imprinted polymers and graphene oxide composites. As a result of electrical signal changes with changing virus concentrations, virus quantitative measurements were achieved [133]. Foot and mouth disease (FMDV) virus diagnosis was carried out using viral imprinted polymer (VIP)-based electrochemical biosensors [134]. Two different serotypes (FMDV-O and FMDV-SAT2) have been identified and determined in real animal samples using two different voltammetric VIP biosensors. In terms of serotype O diagnosis, selective bio-recognition components were formed on a gold screen-printed electrode (SPE) via the electrochemical polymerization of the oxidized form, O-aminophenol (O-AP), with the in-activated whole-virus particles. CV, atomic force microscopy (AFM), field emission-scanning electron microscopy (FE-SEM), and Fourier-transform infrared spectroscopy (FTIR) have been used for the VIP surface characterizations. A cross-reactivity study was carried out on several interfering viruses including FMD serotypes A, SAT2, and lumpy skin disease virus (LSDV). With high selectivity, a limit of detection and quantification of 2 ng/mL and 6 ng/mL were obtained, respectively [135]. On the other hand, another VIP biosensor was designed for the FMDV–SAT2 serotype through the direct electrochemical deposition of FMDV inactivated particles within the poly(o-phenylenediamine) (PoD) film on gold–copper nanostructured electrodes. This VIP biosensor was used for the determination of SAT2 serotype in real clinical field specimens without sample treatment [134]. MIP-based electrochemical sensors were developed using poly-m-phenylenediamine on gold electrodes for the SARS-CoV-2-N-protein. The resulting limits of detection and quantification were 15 and 50 fM, respectively [136]. Lately, a double-mediated impedimetric virus biosensor was designed for the rapid detection of the whole SARS-CoV-2 particles. In this study, a mixture of lipophilic electron shuttle (DCIP) and hydrophilic one ferricyanide (FCN) was used for enhancing the electrochemical signals. Additionally, a nanocomposite (carbon nanotubes/tungsten oxides) was exploited for enlarging the imprinted surface area. The sensor provided a very rapid and on-site investigation of whole-virus particles in clinical specimens directly [137]. For ensuring high selectivity, several respiratory interferent viruses were tested, including influenza A viruses (H1N1, H5N1, and H3N2), influenza B, human coronaviruses (hCoVs)-OC43, NL63, 229E, and Middle-East respiratory syndrome coronavirus (MERS-CoV).
Recently, a FET-based biosensor device has been built by immobilizing SARS-CoV-2-S-protein-specific antibodies on graphene nano-sheets. The device can detect the S-protein in the range from 1 to 100 fg/mL. Further, a gold-nanoparticle-based surface-enhanced Raman scattering (SERS) immunobiosensor has been established for the detection of SARS-CoV-2-S-protein in a detection range of 0.77 to 6.07 fg/mL in the PBS and untreated saliva [138]. Besides dual-labeled antibodies tethered to magnetic nanobeads, the sensor has been integrated into the microfluidic chip to detect SARS-CoV-2 nucleocapsid protein in serum at concentrations of 10 to 50 pg/mL in diluted and whole serum. The chips were applied as a smartphone-based diagnostic as well [139]. In conclusion, virus biosensors represent effective diagnostic methods for rapid response and are highly sensitive, with accurate selectivity and the quantitation of viruses in real samples without labeling and without the need for the extraction or purification of genetic material (DNA and RNA) biological molecules, such as DNA or RNA.

5.5. Nano-Electrochemical Biosensors for Heavy Metal Detection

The electrochemical sensing of a variety of environmental targets, such as heavy metals, is strongly dependent on the material types and material structures of the working electrodes. Thus, the surface modification of working electrodes can be further improved for high-specific-recognition elements and high selectivity towards different heavy metal ions. The development of an electrochemical setup using electrodeposited platinum nanoparticles on a glassy carbon electrode (Pt NPs/GCE) for the direct detection of arsenic ions (As3+) using cyclic voltammetry has been achieved by Dai et al. The voltammetric method was optimized to offer a low limit of detection (35 µg/L) [140]. In another study, a polymeric nanocomposite consisted of polyurethane doped with platinum nanoparticles (PU/Pt NPs) with an average size of 2–5 nm was chemically synthesized and applied as a sensing platform for the direct voltammetric detection of Cu2+. A linear range was obtained from 100 to 1000 ng/mL and the limit of detection was 16.72 ng/mL with no interference from different ions. The applicability of this sensor was studied using serum, urine, and acidified tap water samples [141].
Potentially hazardous levels of hexavalent chromium(VI) have been determined in environmental samples using gold-nanoparticle-based electrochemical sensors. The electrochemical parameters have been idealized, and the assay ultrasensitive detection limit was reached (2.38 ng/L) [142]. In addition, one of the most toxic elements (mercury(II)) was also determined electrochemically using nanomaterial-based electrodes. In this regard, poly(ester-urethane) urea conjugated with gold nanoparticles (PUU/Au NPs) was used to modify a carbon paste electrode (CPE) to implement the highly sensitive detection of mercury ions in fish tissue [143]. The sensor showed a linear range of 5 to 155 ng/mL, while the calculated values of the limit of detection and limit of quantification were 0.235 ng/mL and 0.710 ng/mL, respectively. One of the carbon-based nanomaterials, carbon nanofibers (CNFs) were synthesized and characterized to be applied in the electrochemical determination of lead ions (Pb(II). This study was demonstrated by Robinson et al. [144], wherein nano-electrode arrays were fabricated from the vertically aligned forms of carbon nanofibers (VACNFs). The nano-electrodes enhanced the anodic stripping voltammetric performance for the lead ion determination, while the limit of detection was found to be 1.73 nM.
Furthermore, the sensitive and selective impedimetric detection of cadmium ions (cadmium (II)) was achieved when disposable screen-printed electrodes were modified with a nanocellulose/ligand/CNT/Co3O4-nanocomposite.
Thus, the nanocellulose-intercalated nanomaterial improved the electrochemical assay, whereas the limit of detection was found to be 1.5 × 10−13 M [44]. To conclude the importance of nanomaterials in heavy metal detection using electrochemical sensors, metal nanoparticles and carbon-based materials have been extensively investigated as electrode modifiers and reported for various heavy metal analyses in environmental and biological samples [141,143].

6. Global Market of Biosensors

Biosensor demands are expanding and receiving huge attention due to a variety of biomedical applications, a growing diabetic population, a high need for portable diagnostic devices, and quick technological advancements. Accordingly, accurate and early disease diagnosis is critical for a positive disease prognosis and patient survival. The demand for disposable, wearable, user-friendly, and cost-effective devices with quick response times has increased rapidly in recent years. These devices have made rapid progress in the medical field due to their ability to meet these criteria through an interdisciplinary combination of approaches from chemistry, biology, virology, nanotechnology, medical science, and electronics. Nano-biosensors, which incorporate nanotechnology, are expected to find beneficial uses in various industrial actions, such as food quality control monitoring, imaging operations, and pathogenic activity detection. Hence, the biosensors market is consolidating due to the rising popularity of medical equipment and tailored medications, the increased preference for disposable and non-invasive biosensors, and increased research collaboration and agreements between diverse manufacturers and research institutions. The forecast of the global biosensors market size was valued at 24.9 billion US dollars in 2022 and is expected to expand at a compound annual growth rate (CAGR) of 8.0% from 2022 to 2030. Biosensors have great abilities in the diagnosis of infection and biomarker diseases. Thus, plenty of biosensing technologies will be available in the market. Electrochemical and optical biosensors are the most used techniques for the development of point-of-care devices (POC) for the quantitative determination of biomarkers, as well as for infectious diseases.

7. Conclusions, Future Remarks, and Perspectives

As an effective analytical tool, biosensors have been involved in important fields, such as biomedical diagnostics, disease monitoring, and environmental analysis. A biosensor is a system that can offer a quantitative and selective tracking of a single- or multiple-targeting analyte(s), e.g., cancer biomarkers, DNAs, toxins, heavy metals, drugs, toxic gases, etc.), exploiting the existence of one or several bio-recognition elements and a signal transduction compartment. Among the common biosensors, electrochemical biosensors are the most extensively investigated types, as they offer the advantage of a low detection limit, high specificity, simplicity of construction, and ease of operation. As a new biosensor generation, nano-electrochemical sensors and nano-biosensors have been developed using versatile nanostructures, which led to great enhancement in biosensor performance. Moreover, and because of all the progress and advancement made for electronic instrumentation, versatile, multiplexed, and cost-effective bio-sensing portable digital devices have been produced and commercialized as lab-on-chip devices for on-site and at-home diagnosis. Accordingly, about two-hundred companies are investing in biosensor and bioelectronic fabrication and commercialization. However, from all existing products, about 85 to 90% are going for glucose monitoring in blood patients. The other biosensing platforms are still considered laboratory-based experiments or laboratory-designed platforms. Thus, to transfer those laboratory-designed biosensing platforms to the diagnostic market (i.e real commercialization), strong cooperation is required within the industry and researchers from universities and academic institutes (covering all disciplines and needed backgrounds from materials science, chemistry, physics, biomedicine, microbiology/biology, and engineering). This academic–industry cooperation is urgently needed in order to solve and overcome the challenges and problems in terms of sensor stability, cost, lifetime, and accuracy and precision. From another perspective, future wearable biosensing devices will enable the non-invasive (no-pain) monitoring and testing for various analytes including glucose, metabolites, proteins, and nucleic acids, eventually permitting sophisticated performance and self-diagnosis. Consequently, wearable biosensing devices are predicted to be the fashions of modern biosensors (starting from wrist-mounted, stretchable, soft chips to fashion accessories and daily textiles). However, medical doctors and biomedical societies still reject and resist using such technology (i.e., non-invasive biosensors) without extensive validation and successful applications in human testing with better understanding of the clinical relevance of sensor information. Towards the far future of nano-biosensors and wearable devices, integration between artificial intelligence (AI), machine learning (ML) methods, nanotechnology, and nano-electronics could achieve impressive advances in designing and fabricating smart nano-biosensors that satisfy the biosensors global market and impact sensor commercialization.

Funding

This state-of-the art article is supported by the Science, Technology & Innovation Funding Authority (STDF, Cairo, Egypt) through funding the research project (Title: Detection of biologically active Enterotoxins of Staphylococcus, ID: 33682, German-Egyptian Research Fund (GERF)).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

This state-of-the-art article is supported by the Science, Technology & Innovation Funding Authority (STDF) under grant number: 33682.

Conflicts of Interest

The author declares no conflict of interest.

References

  1. Plata, M.R.; Contento, A.M.; Ríos, A. State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups. Sensors 2010, 10, 2511–2576. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Bhalla, N.; Jolly, P.; Formisano, N.; Estrela, P. Introduction to biosensors. Essays Biochem. 2016, 60, 1–8. [Google Scholar] [PubMed] [Green Version]
  3. Kirsch, J.; Siltanen, C.; Zhou, Q.; Revzin, A.; Simonian, A. Biosensor technology: Recent advances in threat agent detection and medicine. Chem. Soc. Rev. 2013, 42, 8733–8768. [Google Scholar] [CrossRef] [PubMed]
  4. Castillo, J.; Gáspár, S.; Leth, S.; Niculescu, M.; Mortari, A.; Bontidean, I.; Soukharev, V.; Dorneanu, S.A.; Ryabov, A.D.; Csöregi, E. Biosensors for life quality: Design, development and applications. Sens. Actuators B Chem. 2004, 102, 179–194. [Google Scholar] [CrossRef]
  5. Grieshaber, D.; MacKenzie, R.; Vörös, J.; Reimhult, E. Electrochemical Biosensors—Sensor Principles and Architectures. Sensors 2008, 8, 1400–1458. [Google Scholar] [CrossRef] [PubMed]
  6. Naresh, V.; Lee, N. A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors. Sensors 2021, 21, 1109. [Google Scholar] [CrossRef] [PubMed]
  7. Nguyen, H.H.; Lee, S.H.; Lee, U.J.; Fermin, C.D.; Kim, M. Immobilized Enzymes in Biosensor Applications. Materials 2019, 12, 121. [Google Scholar] [CrossRef] [Green Version]
  8. Putzbach, W.; Ronkainen, N.J. Immobilization techniques in the fabrication of nanomaterial-based electrochemical biosensors: A review. Sensors 2013, 13, 4811–4840. [Google Scholar] [CrossRef]
  9. Nemiwal, M.; Zhang, T.C.; Kumar, D. Enzyme immobilized nanomaterials as electrochemical biosensors for detection of biomolecules. Enzym. Microb. Technol. 2022, 156, 110006. [Google Scholar] [CrossRef]
  10. Malhotra, B.D.; Ali, M.A. Chapter 1—Nanomaterials in Biosensors: Fundamentals and Applications. In Nanomaterials for Biosensors; Malhotra, B.D., Ali, M.A., Eds.; William Andrew Publishing: Norwich, NY, USA, 2018; pp. 1–74. [Google Scholar]
  11. Kim, J.; Campbell, A.S.; de Ávila, B.E.-F.; Wang, J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 2019, 37, 389–406. [Google Scholar] [CrossRef]
  12. Hussein, H.A.; Hassan, R.Y.A.; Chino, M.; Febbraio, F. Point-of-Care Diagnostics of COVID-19: From Current Work to Future Perspectives. Sensors 2020, 20, 4289. [Google Scholar] [CrossRef] [PubMed]
  13. Subbaiah, G.B.; Ratnam, K.V.; Janardhan, S.; Shiprath, K.; Manjunatha, H.; Ramesha, M.; Prasad, N.V.K.; Ramesh, S.; Babu, T.A. Metal and Metal Oxide Based Advanced Ceramics for Electrochemical Biosensors—A Short Review. Front. Mater. 2021, 8, 682025. [Google Scholar] [CrossRef]
  14. Lee, I.; Probst, D.; Klonoff, D.; Sode, K. Continuous glucose monitoring systems - Current status and future perspectives of the flagship technologies in biosensor research. Biosensors and Bioelectronics 2021, 181, 113054. [Google Scholar] [CrossRef] [PubMed]
  15. Updike, S.J.; Hicks, G.P. The Enzyme Electrode. Nature 1967, 214, 986–988. [Google Scholar] [CrossRef]
  16. Guilbault, G.G.; Montalvo, J.G., Jr. A urea-specific enzyme electrode. J. Am. Chem. Soc. 1969, 91, 2164–2165. [Google Scholar] [CrossRef]
  17. Johansson, G.; Ogren, L. An enzyme reactor electrode for urea determinations. Anal. Chim. Acta 1976, 84, 23–29. [Google Scholar] [CrossRef]
  18. Guilbault, G.G.; Lubrano, G.J. An enzyme electrode for the amperometric determination of glucose. Anal. Chim. Acta 1973, 64, 439–455. [Google Scholar] [CrossRef]
  19. Mosbach, K.; Danielsson, B. An enzyme thermistor. Biochim. Biophys. Acta BBA Enzymol. 1974, 364, 140–145. [Google Scholar] [CrossRef]
  20. Lübbers, D.W.; Opitz, N. Die pCO2-/pO2-Optode: Eine neue p CO2- bzw. pO2-Meßsonde zur Messung des pCO2 oder pO2 von Gasen und Flüssigkeiten/The pCO2-/pO2-Optode: A New Probe for Measurement of pCO2 or pO2 in Fluids and Gases. Z. Nat. C 1975, 30, 532–533. [Google Scholar] [CrossRef]
  21. Gao, G.; Fang, D.; Yu, Y.; Wu, L.; Wang, Y.; Zhi, J. A double-mediator based whole cell electrochemical biosensor for acute biotoxicity assessment of wastewater. Talanta 2017, 167, 208–216. [Google Scholar] [CrossRef]
  22. Cass, A.E.G.; Davis, G.; Francis, G.D.; Hill, H.A.O.; Aston, W.J.; Higgins, I.J.; Plotkin, E.V.; Scott, L.D.L.; Turner, A.P.F. Ferrocene-mediated enzyme electrode for amperometric determination of glucose. Anal. Chem. 1984, 56, 667–671. [Google Scholar] [CrossRef] [PubMed]
  23. Clemens, A.H.; Chang, P.H.; Myers, R.W. The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS). Horm. Metab. Res. Horm. Stoffwechs. Horm. Metab. 1977, 7, 23–33. [Google Scholar]
  24. Geyssant, A.; Dormois, D.; Barthelemy, J.C.; Lacour, J.R. Lactate determination with the lactate analyser LA 640: A critical study. Scand. J. Clin. Lab. Investig. 1985, 45, 145–149. [Google Scholar] [CrossRef] [PubMed]
  25. Qin, C.; Chen, C.; Xie, Q.; Wang, L.; He, X.; Huang, Y.; Zhou, Y.; Xie, F.; Yang, D.; Yao, S. Amperometric enzyme electrodes of glucose and lactate based on poly(diallyldimethylammonium)-alginate-metal ion-enzyme biocomposites. Analytica chimica acta 2012, 720, 49–56. [Google Scholar] [CrossRef] [PubMed]
  26. Xu, M.; Obodo, D.; Yadavalli, V.K. The design, fabrication, and applications of flexible biosensing devices. Biosens. Bioelectron. 2019, 124–125, 96–114. [Google Scholar] [CrossRef]
  27. Cho, I.-H.; Kim, D.H.; Park, S. Electrochemical biosensors: Perspective on functional nanomaterials for on-site analysis. Biomater. Res. 2020, 24, 6. [Google Scholar] [CrossRef] [Green Version]
  28. Ding, J.; Qin, W. Recent advances in potentiometric biosensors. TrAC Trends Anal. Chem. 2020, 124, 115803. [Google Scholar] [CrossRef]
  29. Lee, W.I.; Subramanian, A.; Mueller, S.; Levon, K.; Nam, C.Y.; Rafailovich, M.H. Potentiometric Biosensors Based on Molecular-Imprinted Self-Assembled Monolayer Films for Rapid Detection of Influenza A Virus and SARS-CoV-2 Spike Protein. ACS Appl. Nano Mater. 2022, 5, 5045–5055. [Google Scholar] [CrossRef]
  30. Polat, E.O.; Cetin, M.M.; Tabak, A.F.; Bilget Güven, E.; Uysal, B.Ö.; Arsan, T.; Kabbani, A.; Hamed, H.; Gül, S.B. Transducer Technologies for Biosensors and Their Wearable Applications. Biosensors 2022, 12, 385. [Google Scholar] [CrossRef]
  31. Eivazzadeh-Keihan, R.; Noruzi, E.B.; Chidar, E.; Jafari, M.; Davoodi, F.; Kashtiaray, A.; Gorab, M.G.; Hashemi, S.M.; Javanshir, S.; Cohan, R.A.; et al. Applications of carbon-based conductive nanomaterials in biosensors. Chem. Eng. J. 2022, 442, 136183. [Google Scholar] [CrossRef]
  32. Dong, Y.; Luo, X.; Liu, Y.; Yan, C.; Li, H.; Lv, J.; Yang, L.; Cui, Y. A disposable printed amperometric biosensor for clinical evaluation of creatinine in renal function detection. Talanta 2022, 248, 123592. [Google Scholar] [CrossRef] [PubMed]
  33. Shul’ga, A.A.; Soldatkin, A.P.; El’skaya, A.V.; Dzyadevich, S.V.; Patskovsky, S.V.; Strikha, V.I. Thin-film conductometric biosensors for glucose and urea determination. Biosens. Bioelectron. 1994, 9, 217–223. [Google Scholar] [CrossRef]
  34. Soldatkin, O.O.; Peshkova, V.M.; Saiapina, O.Y.; Kucherenko, I.S.; Dudchenko, O.Y.; Melnyk, V.G.; Vasylenko, O.D.; Semenycheva, L.M.; Soldatkin, A.P.; Dzyadevych, S.V. Development of conductometric biosensor array for simultaneous determination of maltose, lactose, sucrose and glucose. Talanta 2013, 115, 200–207. [Google Scholar] [CrossRef] [PubMed]
  35. Magar, H.S.; Hassan, R.Y.A.; Mulchandani, A. Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications. Sensors 2021, 21, 6578. [Google Scholar] [CrossRef]
  36. Leva-Bueno, J.; Peyman, S.A.; Millner, P.A. A review on impedimetric immunosensors for pathogen and biomarker detection. Med. Microbiol. Immunol. 2020, 209, 343–362. [Google Scholar] [CrossRef] [Green Version]
  37. Bertok, T.; Lorencova, L.; Chocholova, E.; Jane, E.; Vikartovska, A.; Kasak, P.; Tkac, J. Electrochemical Impedance Spectroscopy Based Biosensors: Mechanistic Principles, Analytical Examples and Challenges towards Commercialization for Assays of Protein Cancer Biomarkers. ChemElectroChem 2019, 6, 989–1003. [Google Scholar] [CrossRef] [Green Version]
  38. Mohammad-Razdari, A.; Ghasemi-Varnamkhasti, M.; Izadi, Z.; Ensafi, A.A.; Rostami, S.; Siadat, M. An impedimetric aptasensor for ultrasensitive detection of Penicillin G based on the use of reduced graphene oxide and gold nanoparticles. Microchim. Acta 2019, 186, 372. [Google Scholar] [CrossRef]
  39. Kim, D.C.; Kang, D.J. Molecular Recognition and Specific Interactions for Biosensing Applications. Sensors 2008, 8, 6605–6641. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  40. Millner, P.A.; Caygill, R.L.; Conroy, D.J.R.; Shahidan, M.A. 4—Impedance interrogated affinity biosensors for medical applications: Novel targets and mechanistic studies. In Biosensors for Medical Applications; Higson, S., Ed.; Woodhead Publishing: Cambridge, UK, 2012; pp. 103–134. [Google Scholar]
  41. Manickam, A.; Chevalier, A.; McDermott, M.; Ellington, A.D.; Hassibi, A. A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array. IEEE Trans. Biomed. Circuits Syst. 2010, 4, 379–390. [Google Scholar] [CrossRef]
  42. Wang, S.; Zhang, J.; Gharbi, O.; Vivier, V.; Gao, M.; Orazem, M.E. Electrochemical impedance spectroscopy. Nat. Rev. Methods Prim. 2021, 1, 41. [Google Scholar] [CrossRef]
  43. Watanabe, H.; Omoto, S.; Hoshi, Y.; Shitanda, I.; Itagaki, M. Electrochemical impedance analysis on positive electrode in lithium-ion battery with galvanostatic control. J. Power Source 2021, 507, 230258. [Google Scholar] [CrossRef]
  44. Magar, H.S.; Magd, E.E.A.-E.; Hassan, R.Y.A.; Fahim, A.M. Rapid impedimetric detection of cadmium ions using Nanocellulose/ligand/nanocomposite (CNT/Co3O4). Microchem. J. 2022, 182, 107885. [Google Scholar] [CrossRef]
  45. Hassan, R.Y.A.; Bilitewski, U. A viability assay for Candida albicans based on the electron transfer mediator 2,6-dichlorophenolindophenol. Analytical Biochemistry 2011, 419, 26–32. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  46. Hassan, R.Y.A.; El-Attar, R.O.; Hassan, H.N.A.; Ahmed, M.A.; Khaled, E. Carbon nanotube-based electrochemical biosensors for determination of Candida albicans’s quorum sensing molecule. Sens. Actuators B Chem. 2017, 244, 565–570. [Google Scholar] [CrossRef]
  47. El-Raheem, H.A.; Hassan, R.Y.A.; Khaled, R.; Farghali, A.; El-Sherbiny, I.M. Polyurethane-doped platinum nanoparticles modified carbon paste electrode for the sensitive and selective voltammetric determination of free copper ions in biological samples. Microchem. J. 2020, 155, 104765. [Google Scholar] [CrossRef]
  48. Alfadaly, R.A.; Elsayed, A.; Hassan, R.Y.A.; Noureldeen, A.; Darwish, H.; Gebreil, A.S. Microbial Sensing and Removal of Heavy Metals: Bioelectrochemical Detection and Removal of Chromium(VI) and Cadmium(II). Molecules 2021, 26, 2549. [Google Scholar] [CrossRef]
  49. El-Raheem, H.A.; Hassan, R.Y.A.; Khaled, R.; Farghali, A.; El-Sherbiny, I.M. New sensing platform of poly(ester-urethane)urea doped with gold nanoparticles for rapid detection of mercury ions in fish tissue. RSC Adv. 2021, 11, 31845–31854. [Google Scholar] [CrossRef]
  50. Abd El-Haleem, H.S.; Hefnawy, A.; Hassan, R.Y.A.; Badawi, A.H.; El-Sherbiny, I.M. Manganese dioxide-core–shell hyperbranched chitosan (MnO2–HBCs) nano-structured screen printed electrode for enzymatic glucose biosensors. RSC Adv. 2016, 6, 109185–109191. [Google Scholar] [CrossRef]
  51. Hassan, R.Y.A.; Kamel, A.M.; Hashem, M.S.; Hassan, H.N.A.; El-Ghaffar, M.A.A. A new disposable biosensor platform: Carbon nanotube/poly(o-toluidine) nanocomposite for direct biosensing of urea. J. Solid State Electrochem. 2018, 22, 1817–1823. [Google Scholar] [CrossRef]
  52. Hassan, R.Y.A.; Sultan, M.A.; El-Alamin, M.M.A.; Atia, M.A.; Aboul-Enein, H.Y. A Disposable Carbon Nanotubes-screen Printed Electrode (CNTs-SPE) for Determination of the Antifungal Agent Posaconazole in Biological Samples. Electroanalysis 2017, 29, 843–849. [Google Scholar] [CrossRef]
  53. Švancara, I.; Vytřas, K.; Barek, J.; Zima, J. Carbon Paste Electrodes in Modern Electroanalysis. Crit. Rev. Anal. Chem. 2001, 31, 311–345. [Google Scholar] [CrossRef]
  54. Locatelli, C.; Fagioli, F.; Bighi, C.; Garai, T. A Critical Comparison of Hanging Mercury Drop Electrode and Long Lasting Sessile Drop Mercury Electrode in A.C. Anodic Stripping Voltammerty. Anal. Lett. 1984, 17, 623–650. [Google Scholar] [CrossRef]
  55. Mustafa, F.; Hassan, R.Y.A.; Andreescu, S. Multifunctional Nanotechnology—Enabled Sensors for Rapid Capture and Detection of Pathogens. Sensors 2017, 17, 2121. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  56. Hassan, R.Y.A.; Mekawy, M.M.; Ramnani, P.; Mulchandani, A. Monitoring of microbial cell viability using nanostructured electrodes modified with Graphene/Alumina nanocomposite. Biosens. Bioelectron. 2017, 91, 857–862. [Google Scholar] [CrossRef] [PubMed]
  57. Hassan, R.Y.A.; Hassan, H.N.A.; Abdel-Aziz, M.S.; Khaled, E. Nanomaterials-based microbial sensor for direct electrochemical detection of Streptomyces spp. Sens. Actuators B Chem. 2014, 203, 848–853. [Google Scholar] [CrossRef]
  58. Yoon, J.; Lim, J.; Shin, M.; Lee, J.-Y.; Choi, J.-W. Recent progress in nanomaterial-based bioelectronic devices for biocomputing system. Biosens. Bioelectron. 2022, 212, 114427. [Google Scholar] [CrossRef] [PubMed]
  59. Holzinger, M.; Le Goff, A.; Cosnier, S. Nanomaterials for biosensing applications: A review. Front. Chem. 2014, 2, 63. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  60. Zhang, Y.; Wei, Q. The role of nanomaterials in electroanalytical biosensors: A mini review. J. Electroanal. Chem. 2016, 781, 401–409. [Google Scholar] [CrossRef]
  61. Gezgin, Z.; Lee, T.-C.; Huang, Q. Engineering Functional Nanothin Multilayers on Food Packaging: Ice-Nucleating Polyethylene Films. J. Agric. Food Chem. 2013, 61, 5130–5138. [Google Scholar] [CrossRef]
  62. Wang, Y.; Duncan, T.V. Nanoscale sensors for assuring the safety of food products. Curr. Opin. Biotechnol. 2017, 44, 74–86. [Google Scholar] [CrossRef]
  63. Kuzin, Y.; Porfireva, A.; Stepanova, V.; Evtugyn, V.; Stoikov, I.; Evtugyn, G.; Hianik, T. Impedimetric Detection of DNA Damage with the Sensor Based on Silver Nanoparticles and Neutral Red. Electroanalysis 2015, 27, 2800–2808. [Google Scholar] [CrossRef]
  64. Kashish; Gupta, S.; Dubey, S.K.; Prakash, R. Genosensor based on a nanostructured, platinum-modified glassy carbon electrode for Listeria detection. Anal. Methods 2015, 7, 2616–2622. [Google Scholar] [CrossRef]
  65. Madianos, L.; Tsekenis, G.; Skotadis, E.; Patsiouras, L.; Tsoukalas, D. A highly sensitive impedimetric aptasensor for the selective detection of acetamiprid and atrazine based on microwires formed by platinum nanoparticles. Biosens. Bioelectron. 2018, 101, 268–274. [Google Scholar] [CrossRef] [PubMed]
  66. Rick, J.; Tsai, M.-C.; Hwang, B.J. Biosensors Incorporating Bimetallic Nanoparticles. Nanomaterials 2015, 6, 5. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  67. Chen, C.-C.; Lai, Z.-L.; Wang, G.-J.; Wu, C.-Y. Polymerase chain reaction-free detection of hepatitis B virus DNA using a nanostructured impedance biosensor. Biosens. Bioelectron. 2016, 77, 603–608. [Google Scholar] [CrossRef] [PubMed]
  68. Rizwan, M.; Mohd-Naim, N.F.; Ahmed, M.U. Trends and Advances in Electrochemiluminescence Nanobiosensors. Sensors 2018, 18, 166. [Google Scholar] [CrossRef] [Green Version]
  69. Su, L.; Jia, W.; Hou, C.; Lei, Y. Microbial biosensors: A review. Biosens. Bioelectron. 2011, 26, 1788–1799. [Google Scholar] [CrossRef]
  70. Xu, M.; Wang, R.; Li, Y. Electrochemical biosensors for rapid detection of Escherichia coli O157:H7. Talanta 2017, 162, 511–522. [Google Scholar] [CrossRef]
  71. Burlage, R.S.; Tillmann, J. Biosensors of bacterial cells. J. Microbiol. Methods 2017, 138, 2–11. [Google Scholar] [CrossRef]
  72. Guntupalli, R.; Sorokulova, I.; Olsen, E.; Globa, L.; Pustovyy, O.; Vodyanoy, V. Biosensor for detection of antibiotic resistant Staphylococcus bacteria. J. Vis. Exp. 2013, 75, e50474. [Google Scholar] [CrossRef] [Green Version]
  73. Khalid, S.A.; Hassan, R.Y.A.; El Nashar, R.M.; El-Sherbiny, I.M. Voltammetric determination of Salmonella typhimurium in minced beef meat using a chip-based imprinted sensor. RSC Adv. 2022, 12, 3445–3453. [Google Scholar] [CrossRef] [PubMed]
  74. Ahovan, Z.A.; Hashemi, A.; De Plano, L.M.; Gholipourmalekabadi, M.; Seifalian, A. Bacteriophage Based Biosensors: Trends, Outcomes and Challenges. Nanomaterials 2020, 10, 501. [Google Scholar] [CrossRef] [Green Version]
  75. El-Shibiny, A.; El-Sahhar, S.; Adel, M. Phage applications for improving food safety and infection control in Egypt. J. Appl. Microbiol. 2017, 123, 556–567. [Google Scholar] [CrossRef] [PubMed]
  76. Tolba, M.; Ahmed, M.U.; Tlili, C.; Eichenseher, F.; Loessner, M.J.; Zourob, M. A bacteriophage endolysin-based electrochemical impedance biosensor for the rapid detection of Listeria cells. Analyst 2012, 137, 5749–5756. [Google Scholar] [CrossRef]
  77. Barreiros dos Santos, M.; Agusil, J.P.; Prieto-Simón, B.; Sporer, C.; Teixeira, V.; Samitier, J. Highly sensitive detection of pathogen Escherichia coli O157:H7 by electrochemical impedance spectroscopy. Biosens. Bioelectron. 2013, 45, 174–180. [Google Scholar] [CrossRef] [PubMed]
  78. Joung, C.K.; Kim, H.N.; Lim, M.C.; Jeon, T.J.; Kim, H.Y.; Kim, Y.R. A nanoporous membrane-based impedimetric immunosensor for label-free detection of pathogenic bacteria in whole milk. Biosens. Bioelectron. 2013, 44, 210–215. [Google Scholar] [CrossRef]
  79. Chan, K.Y.; Ye, W.W.; Zhang, Y.; Xiao, L.D.; Leung, P.H.; Li, Y.; Yang, M. Ultrasensitive detection of E. coli O157:H7 with biofunctional magnetic bead concentration via nanoporous membrane based electrochemical immunosensor. Biosens. Bioelectron. 2013, 41, 532–537. [Google Scholar] [CrossRef]
  80. Mejri, M.B.; Baccar, H.; Baldrich, E.; Del Campo, F.J.; Helali, S.; Ktari, T.; Simonian, A.; Aouni, M.; Abdelghani, A. Impedance biosensing using phages for bacteria detection: Generation of dual signals as the clue for in-chip assay confirmation. Biosens. Bioelectron. 2010, 26, 1261–1267. [Google Scholar] [CrossRef] [Green Version]
  81. Siddiqui, S.; Dai, Z.; Stavis, C.J.; Zeng, H.; Moldovan, N.; Hamers, R.J.; Carlisle, J.A.; Arumugam, P.U. A quantitative study of detection mechanism of a label-free impedance biosensor using ultrananocrystalline diamond microelectrode array. Biosens. Bioelectron. 2012, 35, 284–290. [Google Scholar] [CrossRef]
  82. Dweik, M.; Stringer, R.C.; Dastider, S.G.; Wu, Y.; Almasri, M.; Barizuddin, S. Specific and targeted detection of viable Escherichia coli O157:H7 using a sensitive and reusable impedance biosensor with dose and time response studies. Talanta 2012, 94, 84–89. [Google Scholar] [CrossRef]
  83. Geng, P.; Zhang, X.; Meng, W.; Wang, Q.; Zhang, W.; Jin, L.; Feng, Z.; Wu, Z. Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy. Electrochim. Acta 2008, 53, 4663–4668. [Google Scholar] [CrossRef]
  84. Maalouf, R.; Fournier-Wirth, C.; Coste, J.; Chebib, H.; Saïkali, Y.; Vittori, O.; Errachid, A.; Cloarec, J.-P.; Martelet, C.; Jaffrezic-Renault, N. Label-Free Detection of Bacteria by Electrochemical Impedance Spectroscopy:  Comparison to Surface Plasmon Resonance. Anal. Chem. 2007, 79, 4879–4886. [Google Scholar] [CrossRef] [PubMed]
  85. Lu, L.; Chee, G.; Yamada, K.; Jun, S. Electrochemical impedance spectroscopic technique with a functionalized microwire sensor for rapid detection of foodborne pathogens. Biosens. Bioelectron. 2013, 42, 492–495. [Google Scholar] [CrossRef] [PubMed]
  86. Guo, X.; Kulkarni, A.; Doepke, A.; Halsall, H.B.; Iyer, S.; Heineman, W.R. Carbohydrate-Based Label-Free Detection of Escherichia coli ORN 178 Using Electrochemical Impedance Spectroscopy. Anal. Chem. 2012, 84, 241–246. [Google Scholar] [CrossRef]
  87. De la Rica, R.; Baldi, A.; Fernández-Sánchez, C.; Matsui, H. Selective Detection of Live Pathogens via Surface-Confined Electric Field Perturbation on Interdigitated Silicon Transducers. Anal. Chem. 2009, 81, 3830–3835. [Google Scholar] [CrossRef] [Green Version]
  88. Joung, C.-K.; Kim, H.-N.; Im, H.-C.; Kim, H.-Y.; Oh, M.-H.; Kim, Y.-R. Ultra-sensitive detection of pathogenic microorganism using surface-engineered impedimetric immunosensor. Sens. Actuators B Chem. 2012, 161, 824–831. [Google Scholar] [CrossRef]
  89. Tlili, C.; Sokullu, E.; Safavieh, M.; Tolba, M.; Ahmed, M.U.; Zourob, M. Bacteria Screening, Viability, And Confirmation Assays Using Bacteriophage-Impedimetric/Loop-Mediated Isothermal Amplification Dual-Response Biosensors. Anal. Chem. 2013, 85, 4893–4901. [Google Scholar] [CrossRef]
  90. Wang, Y.; Ping, J.; Ye, Z.; Wu, J.; Ying, Y. Impedimetric immunosensor based on gold nanoparticles modified graphene paper for label-free detection of Escherichia coli O157:H7. Biosens. Bioelectron. 2013, 49, 492–498. [Google Scholar] [CrossRef]
  91. Shabani, A.; Zourob, M.; Allain, B.; Marquette, C.A.; Lawrence, M.F.; Mandeville, R. Bacteriophage-Modified Microarrays for the Direct Impedimetric Detection of Bacteria. Anal. Chem. 2008, 80, 9475–9482. [Google Scholar] [CrossRef]
  92. Wan, Y.; Lin, Z.; Zhang, D.; Wang, Y.; Hou, B. Impedimetric immunosensor doped with reduced graphene sheets fabricated by controllable electrodeposition for the non-labelled detection of bacteria. Biosens. Bioelectron. 2011, 26, 1959–1964. [Google Scholar] [CrossRef]
  93. Qi, P.; Wan, Y.; Zhang, D. Impedimetric biosensor based on cell-mediated bioimprinted films for bacterial detection. Biosens. Bioelectron. 2013, 39, 282–288. [Google Scholar] [CrossRef] [PubMed]
  94. Wan, Y.; Zhang, D.; Wang, Y.; Hou, B. A 3D-impedimetric immunosensor based on foam Ni for detection of sulfate-reducing bacteria. Electrochem. Commun. 2010, 12, 288–291. [Google Scholar] [CrossRef]
  95. Mantzila, A.G.; Maipa, V.; Prodromidis, M.I. Development of a Faradic Impedimetric Immunosensor for the Detection of Salmonella typhimurium in Milk. Anal. Chem. 2008, 80, 1169–1175. [Google Scholar] [CrossRef] [PubMed]
  96. La Belle, J.T.; Shah, M.; Reed, J.; Nandakumar, V.; Alford, T.L.; Wilson, J.W.; Nickerson, C.A.; Joshi, L. Label-Free and Ultra-Low Level Detection of Salmonella enterica Serovar Typhimurium Using Electrochemical Impedance Spectroscopy. Electroanalysis 2009, 21, 2267–2271. [Google Scholar] [CrossRef]
  97. Pournaras, A.V.; Koraki, T.; Prodromidis, M.I. Development of an impedimetric immunosensor based on electropolymerized polytyramine films for the direct detection of Salmonella typhimurium in pure cultures of type strains and inoculated real samples. Anal. Chim. Acta 2008, 624, 301–307. [Google Scholar] [CrossRef] [PubMed]
  98. Huang, J.; Yang, G.; Meng, W.; Wu, L.; Zhu, A.; Jiao, X. An electrochemical impedimetric immunosensor for label-free detection of Campylobacter jejuni in diarrhea patients’ stool based on O-carboxymethylchitosan surface modified Fe3O4 nanoparticles. Biosens. Bioelectron. 2010, 25, 1204–1211. [Google Scholar] [CrossRef] [PubMed]
  99. Tan, F.; Leung, P.H.M.; Liu, Z.-b.; Zhang, Y.; Xiao, L.; Ye, W.; Zhang, X.; Yi, L.; Yang, M. A PDMS microfluidic impedance immunosensor for E. coli O157:H7 and Staphylococcus aureus detection via antibody-immobilized nanoporous membrane. Sens. Actuators B Chem. 2011, 159, 328–335. [Google Scholar] [CrossRef]
  100. Tian, Y.; Du, L.; Zhu, P.; Chen, Y.; Chen, W.; Wu, C.; Wang, P. Recent progress in micro/nano biosensors for shellfish toxin detection. Biosens. Bioelectron. 2021, 176, 112899. [Google Scholar] [CrossRef]
  101. Kumar, V.; Guleria, P.; Mehta, S.K. Nanosensors for food quality and safety assessment. Environ. Chem. Lett. 2017, 15, 165–177. [Google Scholar] [CrossRef]
  102. Nodoushan, S.M.; Nasirizadeh, N.; Amani, J.; Halabian, R.; Fooladi, A.A.I. An electrochemical aptasensor for staphylococcal enterotoxin B detection based on reduced graphene oxide and gold nano-urchins. Biosens. Bioelectron. 2019, 127, 221–228. [Google Scholar] [CrossRef]
  103. Chatrathi, M.P.; Wang, J.; Collins, G.E. Sandwich electrochemical immunoassay for the detection of Staphylococcal enterotoxin B based on immobilized thiolated antibodies. Biosens. Bioelectron. 2007, 22, 2932–2938. [Google Scholar] [CrossRef] [PubMed]
  104. Sharma, A.; Rao, V.K.; Kamboj, D.V.; Gaur, R.; Shaik, M.; Shrivastava, A.R. Enzyme free detection of staphylococcal enterotoxin B (SEB) using ferrocene carboxylic acid labeled monoclonal antibodies: An electrochemical approach. New J. Chem. 2016, 40, 8334–8341. [Google Scholar] [CrossRef]
  105. Gupta, R.; Raza, N.; Bhardwaj, S.K.; Vikrant, K.; Kim, K.-H.; Bhardwaj, N. Advances in nanomaterial-based electrochemical biosensors for the detection of microbial toxins, pathogenic bacteria in food matrices. J. Hazard. Mater. 2021, 401, 123379. [Google Scholar] [CrossRef] [PubMed]
  106. Chin-Chan, M.; Navarro-Yepes, J.; Quintanilla-Vega, B. Environmental pollutants as risk factors for neurodegenerative disorders: Alzheimer and Parkinson diseases. Front. Cell. Neurosci. 2015, 9, 124. [Google Scholar] [CrossRef] [Green Version]
  107. Ajiboye, T.O.; Oladoye, P.O.; Olanrewaju, C.A.; Akinsola, G.O. Organophosphorus pesticides: Impacts, detection and removal strategies. Environ. Nanotechnol. Monit. Manag. 2022, 17, 100655. [Google Scholar] [CrossRef]
  108. Yu, G.; Wu, W.; Zhao, Q.; Wei, X.; Lu, Q. Efficient immobilization of acetylcholinesterase onto amino functionalized carbon nanotubes for the fabrication of high sensitive organophosphorus pesticides biosensors. Biosens. Bioelectron. 2015, 68, 288–294. [Google Scholar] [CrossRef]
  109. Vinotha Alex, A.; Mukherjee, A. Review of recent developments (2018–2020) on acetylcholinesterase inhibition based biosensors for organophosphorus pesticides detection. Microchem. J. 2021, 161, 105779. [Google Scholar] [CrossRef]
  110. Hassan, R.Y.A.; Febbraio, F.; Andreescu, S. Microbial Electrochemical Systems: Principles, Construction and Biosensing Applications. Sensors 2021, 21, 1279. [Google Scholar] [CrossRef]
  111. Arafa, K.K.; Ibrahim, A.; Mergawy, R.; El-Sherbiny, I.M.; Febbraio, F.; Hassan, R.Y.A. Advances in Cancer Diagnosis: Bio-Electrochemical and Biophysical Characterizations of Cancer Cells. Micromachines 2022, 13, 1401. [Google Scholar] [CrossRef]
  112. Yu, J.; Yang, A.; Wang, N.; Ling, H.; Song, J.; Chen, X.; Lian, Y.; Zhang, Z.; Yan, F.; Gu, M. Highly sensitive detection of caspase-3 activity based on peptide-modified organic electrochemical transistor biosensors. Nanoscale 2021, 13, 2868–2874. [Google Scholar] [CrossRef]
  113. Deng, D.; Hao, Y.; Yang, S.; Han, Q.; Liu, L.; Xiang, Y.; Tu, F.; Xia, N. A signal-on electrochemical biosensor for evaluation of caspase-3 activity and cell apoptosis by the generation of molecular electrocatalysts on graphene electrode surface for water oxidation. Sensors Actuators B Chemical 2019, 286, 415–420. [Google Scholar] [CrossRef]
  114. Frączyk, T. Phosphorylation Impacts Cu(II) Binding by ATCUN Motifs. Inorg. Chem. 2021, 60, 8447–8450. [Google Scholar] [CrossRef] [PubMed]
  115. Kieninger, J.; Tamari, Y.; Enderle, B.; Jobst, G.; Sandvik, J.A.; Pettersen, E.O.; Urban, G.A. Sensor Access to the Cellular Microenvironment Using the Sensing Cell Culture Flask. Biosensors 2018, 8, 44. [Google Scholar] [CrossRef] [Green Version]
  116. Flamm, H.; Kieninger, J.; Weltin, A.; Urban, G.A. Superoxide microsensor integrated into a Sensing Cell Culture Flask microsystem using direct oxidation for cell culture application. Biosens. Bioelectron. 2015, 65, 354–359. [Google Scholar] [CrossRef]
  117. Oliveira, M.; Conceição, P.; Kant, K.; Ainla, A.; Diéguez, L. Electrochemical Sensing in 3D Cell Culture Models: New Tools for Developing Better Cancer Diagnostics and Treatments. Cancers 2021, 13, 1381. [Google Scholar] [CrossRef] [PubMed]
  118. Shamsipur, M.; Pashabadi, A.; Molaabasi, F.; Hosseinkhani, S. Impedimetric monitoring of apoptosis using cytochrome-aptamer bioconjugated silver nanocluster. Biosens. Bioelectron. 2017, 90, 195–202. [Google Scholar] [CrossRef] [PubMed]
  119. Zhou, S.; Wang, Y.; Zhu, J.J. Simultaneous Detection of Tumor Cell Apoptosis Regulators Bcl-2 and Bax through a Dual-Signal-Marked Electrochemical Immunosensor. ACS Appl. Mater. Interfaces 2016, 8, 7674–7682. [Google Scholar] [CrossRef]
  120. Li, X.-L.; Shan, S.; Xiong, M.; Xia, X.-H.; Xu, J.-j.; Chen, H.-Y. On-chip selective capture of cancer cells and ultrasensitive fluorescence detection of survivin mRNA in a single living cell. Lab A Chip 2013, 13, 3868–3875. [Google Scholar] [CrossRef]
  121. Xu, J.; Wang, X.; Yan, C.; Chen, W. A Polyamidoamine Dendrimer-Based Electrochemical Immunosensor for Label-Free Determination of Epithelial Cell Adhesion Molecule- Expressing Cancer Cells. Sensors 2019, 19, 1879. [Google Scholar] [CrossRef] [Green Version]
  122. Valverde, A.; Povedano, E.; Montiel, V.R.-V.; Yáñez-Sedeño, P.; Garranzo-Asensio, M.; Barderas, R.; Campuzano, S.; Pingarrón, J.M. Electrochemical immunosensor for IL-13 Receptor α2 determination and discrimination of metastatic colon cancer cells. Biosens. Bioelectron. 2018, 117, 766–772. [Google Scholar] [CrossRef]
  123. Majidi, M.R.; Karami, P.; Johari-Ahar, M.; Omidi, Y. Direct detection of tryptophan for rapid diagnosis of cancer cell metastasis competence by an ultra-sensitive and highly selective electrochemical biosensor. Anal. Methods 2016, 8, 7910–7919. [Google Scholar] [CrossRef]
  124. Muñoz-San Martín, C.; Pedrero, M.; Gamella, M.; Montero-Calle, A.; Barderas, R.; Campuzano, S.; Pingarrón, J.M. A novel peptide-based electrochemical biosensor for the determination of a metastasis-linked protease in pancreatic cancer cells. Anal. Bioanal. Chem. 2020, 412, 6177–6188. [Google Scholar] [CrossRef] [PubMed]
  125. Muñoz-San Martín, C.; Gamella, M.; Pedrero, M.; Montero-Calle, A.; Pérez-Ginés, V.; Camps, J.; Arenas, M.; Barderas, R.; Pingarrón, J.M.; Campuzano, S. Anticipating metastasis through electrochemical immunosensing of tumor hypoxia biomarkers. Anal. Bioanal. Chem. 2022, 414, 399–412. [Google Scholar] [CrossRef] [PubMed]
  126. Gast, M.; Sobek, H.; Mizaikoff, B. Advances in imprinting strategies for selective virus recognition a review. TrAC Trends Anal. Chem. 2019, 114, 218–232. [Google Scholar] [CrossRef]
  127. Piletska, E.V.; Mirkes, E.; Piletsky, S.S.; Abosoglu, H.; Cassim, A.; Chu, E.; Doughty, S.; Eganda, S.-J.; Fuchigami, H.; Hussein, A.; et al. Combinatorial screening of polymer nanoparticles for their ability to recognize epitopes of AAV-neutralizing antibodies. J. Mol. Recognit. 2020, 33, e2824. [Google Scholar] [CrossRef]
  128. Gast, M.; Sobek, H.; Mizaikoff, B. Selective virus capture via hexon imprinting. Mater. Sci. Eng. C 2019, 99, 1099–1104. [Google Scholar] [CrossRef]
  129. Graham, S.P.; El-Sharif, H.F.; Hussain, S.; Fruengel, R.; McLean, R.K.; Hawes, P.C.; Sullivan, M.V.; Reddy, S.M. Evaluation of Molecularly Imprinted Polymers as Synthetic Virus Neutralizing Antibody Mimics. Front. Bioeng. Biotechnol. 2019, 7, 115. [Google Scholar] [CrossRef]
  130. Arshad, R.; Rhouati, A.; Hayat, A.; Nawaz, M.H.; Yameen, M.A.; Mujahid, A.; Latif, U. MIP-Based Impedimetric Sensor for Detecting Dengue Fever Biomarker. Appl. Biochem. Biotechnol. 2020, 191, 1384–1394. [Google Scholar] [CrossRef]
  131. Luo, L.; Zhang, F.; Chen, C.; Cai, C. Molecular imprinting resonance light scattering nanoprobes based on pH-responsive metal-organic framework for determination of hepatitis A virus. Microchim. Acta 2020, 187, 140. [Google Scholar] [CrossRef]
  132. Chowdhury, A.D.; Takemura, K.; Li, T.-C.; Suzuki, T.; Park, E.Y. Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection. Nat. Commun. 2019, 10, 3737. [Google Scholar] [CrossRef] [Green Version]
  133. Tancharoen, C.; Sukjee, W.; Thepparit, C.; Jaimipuk, T.; Auewarakul, P.; Thitithanyanont, A.; Sangma, C. Electrochemical Biosensor Based on Surface Imprinting for Zika Virus Detection in Serum. ACS Sens. 2019, 4, 69–75. [Google Scholar] [CrossRef] [PubMed]
  134. Hussein, H.A.; El Nashar, R.M.; El-Sherbiny, I.M.; Hassan, R.Y.A. High selectivity detection of FMDV- SAT-2 using a newly-developed electrochemical nanosensors. Biosens. Bioelectron. 2021, 191, 113435. [Google Scholar] [CrossRef] [PubMed]
  135. Hussein, H.A.; Hassan, R.Y.A.; El Nashar, R.M.; Khalil, S.A.; Salem, S.A.; El-Sherbiny, I.M. Designing and fabrication of new VIP biosensor for the rapid and selective detection of foot-and-mouth disease virus (FMDV). Biosens. Bioelectron. 2019, 141, 111467. [Google Scholar] [CrossRef] [PubMed]
  136. Raziq, A.; Kidakova, A.; Boroznjak, R.; Reut, J.; Öpik, A.; Syritski, V. Development of a portable MIP-based electrochemical sensor for detection of SARS-CoV-2 antigen. Biosens. Bioelectron. 2021, 178, 113029. [Google Scholar] [CrossRef] [PubMed]
  137. Hussein, H.A.; Kandeil, A.; Gomaa, M.; Mohamed El Nashar, R.; El-Sherbiny, I.M.; Hassan, R.Y.A. SARS-CoV-2-Impedimetric Biosensor: Virus-Imprinted Chips for Early and Rapid Diagnosis. ACS Sens. 2021, 6, 4098–4107. [Google Scholar] [CrossRef]
  138. Zhang, M.; Li, X.; Pan, J.; Zhang, Y.; Zhang, L.; Wang, C.; Yan, X.; Liu, X.; Lu, G. Ultrasensitive detection of SARS-CoV-2 spike protein in untreated saliva using SERS-based biosensor. Biosens. Bioelectron. 2021, 190, 113421. [Google Scholar] [CrossRef]
  139. Li, J.; Lillehoj, P.B. Microfluidic Magneto Immunosensor for Rapid, High Sensitivity Measurements of SARS-CoV-2 Nucleocapsid Protein in Serum. ACS Sens. 2021, 6, 1270–1278. [Google Scholar] [CrossRef]
  140. Dai, X.; Compton, R.G. Detection of as (III) via oxidation to As (V) using platinum nanoparticle modified glassy carbon electrodes: Arsenic detection without interference from copper. Analyst 2006, 131, 516–521. [Google Scholar] [CrossRef]
  141. Aragay, G.; Merkoçi, A. Nanomaterials application in electrochemical detection of heavy metals. Electrochimica Acta 2012, 84, 49–61. [Google Scholar] [CrossRef]
  142. Wyantuti, S.; Ishmayana, S.; Hartati, Y.W. Voltammetric Determination of Cr(VI) Using Gold Nanoparticles-modified Glassy Carbon Electrode. Procedia Chem. 2015, 16, 15–23. [Google Scholar] [CrossRef] [Green Version]
  143. March, G.; Nguyen, T.D.; Piro, B. Modified Electrodes Used for Electrochemical Detection of Metal Ions in Environmental Analysis. Biosensors 2015, 5, 241–275. [Google Scholar] [CrossRef] [PubMed]
  144. Robinson, J.E.; Heineman, W.R.; Sagle, L.B.; Meyyappan, M.; Koehne, J.E. Carbon nanofiber electrode array for the detection of lead. Electrochem. Commun. 2016, 73, 89–93. [Google Scholar] [CrossRef]
Figure 3. A simple demonstration to visualize what is going in the EIS systems during the conducting of experiments and before generating the EIS signals. At the electrode surface (definitely the side that faces the electrolyte containing the electroactive redox probe), oxidation and/or reduction will take place, which leads to an electron transfer or electron exchange. The diffusion, as well as the catalytic properties, will create different resistances including the charge transfer resistance (Rct). To manipulate the EIS date, simulation or modeling through drawing on an electrical circuit (Randes cell) made of double-layer capacitors, solution resistance, and charge transfer resistance is needed.
Figure 3. A simple demonstration to visualize what is going in the EIS systems during the conducting of experiments and before generating the EIS signals. At the electrode surface (definitely the side that faces the electrolyte containing the electroactive redox probe), oxidation and/or reduction will take place, which leads to an electron transfer or electron exchange. The diffusion, as well as the catalytic properties, will create different resistances including the charge transfer resistance (Rct). To manipulate the EIS date, simulation or modeling through drawing on an electrical circuit (Randes cell) made of double-layer capacitors, solution resistance, and charge transfer resistance is needed.
Sensors 22 07539 g003
Figure 4. Impedance data in the Nyquist plot format showing up the change of the charge transfer resistances (Rct) due to the addition of a different concentration of cadmium ions into the electrochemical cell, which is connected with a disposable screen-printed electrode modified with a ligand/nanocellulose nanocomposite. (The equivalent circuit, inserted figure, was used for quantitative analysis [44].
Figure 4. Impedance data in the Nyquist plot format showing up the change of the charge transfer resistances (Rct) due to the addition of a different concentration of cadmium ions into the electrochemical cell, which is connected with a disposable screen-printed electrode modified with a ligand/nanocellulose nanocomposite. (The equivalent circuit, inserted figure, was used for quantitative analysis [44].
Sensors 22 07539 g004
Figure 5. The most commonly used working electrode types and materials in electrochemical sensors and biosensors.
Figure 5. The most commonly used working electrode types and materials in electrochemical sensors and biosensors.
Sensors 22 07539 g005
Figure 7. A new vision for cancer investigation through combinatorial biochemical and biophysical techniques.
Figure 7. A new vision for cancer investigation through combinatorial biochemical and biophysical techniques.
Sensors 22 07539 g007
Table 1. Examples of microbial detection using nanomaterial-modified electrochemical sensors.
Table 1. Examples of microbial detection using nanomaterial-modified electrochemical sensors.
Bacterium(a)TransducerChemistryBio-ReceptorLODReference
E. coli O157:H7GoldEDC/NHSAntibody2 CFU/mL[77]
E. coli O157:H7Nanoporous aluminum oxide membraneTrimethoxysilane-HA-EDC/NHSAntibody10 CFU/mL[78]
E. coli O157:H7Nanoporous aluminum oxide membraneSilane-PEGAntibody10 CFU/mL[79]
E. coli K-12Gold microelectrode, interdigitatedPhysisorptionT4 bacteriophage104–107 CFU/mL[80]
E. coli K-12Boron-doped microelectrode arrayPhysisorptionAntibodyNA[81]
E. coli O157:H7Gold microelectrode, interdigitatedPhysisorptionAntibody2.5 × 104 CFU/mL[82]
E. coliGoldSAM-EDC/NHSAntibody1.0–103 CFU/mL[83]
E. coliGold electrodeSAM-biotin-NeutrAvidinBiotinyl antibody10 CFU/mL[84]
E. coligold-tungsten plate wirePolyethyleneamine-streptavidinBiotinyl antibody103–108 CFU/mL[85]
E. coliGold diskSAMSynthetic glycan102–103 CFU/mL[86]
E. coliPolysilicon interdigitated electrodesGlutaraldehydeAntibody3 × 102 CFU/mL[87]
E. coli O157:H7GoldSAM-HA-EDC/NHSAntibody7 CFU/mL[88]
E. coliGoldSAM-PDICT cross-linkerBacteriophage8 × 102 CFU/mL[89]
E. coliGraphene paperBiotin-streptavidinAntibody1.5 × 102 CFU/mL[90]
E. coliScreen-printed carbon microarraysEDC/NHSBacteriophage104 CFU/mL[91]
Sulfate-reducing bacteriaGlassy carbonReduced graphene sheet with chitosan–glutaraldehydeAntibody1.8 × 101 CFU/mL[92]
Sulfate-reducing bacteriaITOChitosan-reduced grapheme sheetBioimprint of bacteria1.0 × 104 CFU/mL[93]
Sulfate-reducing bacteriaNi-foamNanoparticle-SAM-EDC/NHSAntibody2.1 × 10 CFU/mL[94]
Salmonella typhimuriumGoldSAM-glutaraldehydeAntibodyNA[95]
Salmonella typhimuriumElectroplated gold MHDA-EDC-NHSMonoclonal antibody10 CFU/100 mL[96]
Salmonella typhimuriumGoldPolytyramine-glutaraldehydeAntibodyNA[97]
Campylobacter jejuniGlassy carbonPhysisorped onto Ocarboxymethylchitos-modified Fe3O4 nanoparticlesMonoclonal antibody1.0 × 103 CFU/mL[98]
Listeria innocuaGoldSAM-EDC/NHSEndolysin (bacteriophage-encoded peptidoglycan hydrolases)1.1 × 104 CFU/mL[76]
Staphylococcus aureusNanoporous aluminaSilane-GPMSAntibody102 CFU/mL[99]
Porphyromonas gingivalis, E. coliMicrofluidic cell Impedance reading during flow of cellsNone103 cells/mL[77]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hassan, R.Y.A. Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives. Sensors 2022, 22, 7539. https://doi.org/10.3390/s22197539

AMA Style

Hassan RYA. Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives. Sensors. 2022; 22(19):7539. https://doi.org/10.3390/s22197539

Chicago/Turabian Style

Hassan, Rabeay Y. A. 2022. "Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives" Sensors 22, no. 19: 7539. https://doi.org/10.3390/s22197539

APA Style

Hassan, R. Y. A. (2022). Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives. Sensors, 22(19), 7539. https://doi.org/10.3390/s22197539

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop