Article
Peer-Review Record

A Power-Line Communication System Governed by Loop Resonance for Photovoltaic Plant Monitoring

Sensors 2022, 22(23), 9207; https://doi.org/10.3390/s22239207
by José Ignacio Morales-Aragones 1, Matthew St. Michael Williams 2, Halleluyah Kupolati 3, Víctor Alonso-Gómez 1, Sara Gallardo-Saavedra 4, Alberto Redondo-Plaza 4, Miguel Ángel Muñoz-García 5, Francisco José Sánchez-Pacheco 6 and Luis Hernández-Callejo 7,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Sensors 2022, 22(23), 9207; https://doi.org/10.3390/s22239207
Submission received: 7 October 2022 / Revised: 8 November 2022 / Accepted: 24 November 2022 / Published: 26 November 2022
(This article belongs to the Special Issue Sensing Technologies Applied in Solar Energy and Photovoltaic Systems)

Round 1

Reviewer 1 Report

In this paper low-cost and extremely simple transceivers intended to be installed within each PV module of a string have been designed and successfully tested. In addition, an anti-saturation coil has been conceived to avoid saturation of the core when the entire DC of the string flows through it. It’s an interesting work, however, I have the following concerns:

· Most references are very old, please add the latest papers in the introduction section.

· References numbering is anonymous as [2] and [3] are given after the [2]-[4], please arrange the reference numbering according to the standard format.

· Some sentences are senseless such as in line 91, “ [8] employed pulse modulation as well but instead in the voltage domain through capacitive coupling for a low AC impedance transmission path” So, check the whole paper properly to update considering the grammar mistakes.

· In line 265, why to use the anti-saturation coil with the PV module, please give some details.

· In the results, the cost and performance comparison with the existing work is not presented. Please provide the comparison for the validation.

· In line 331, how it is validated that the proposed model has less cost as compared to the available models.

· The conclusion section should be added to the paper to conclude the findings.

Author Response

Thank you for your suggestions, the answers are in the attached file.

Author Response File: Author Response.pdf

Reviewer 2 Report

Congratulations for the work done. I have some questions regarding what you have written.

In line 172, you wrote "C is the capacitance...". Please indicate in figure 1 or in the text which capacitance is C. 

There is no uncertainty discussion of results.

Discussion must be rewritten in form of conclusions.

Were the measurements carried out while the plant was in operation, or in the absence of power supply?

Author Response

Thank you for your suggestions, the answers are in the attached file.

Author Response File: Author Response.pdf

Round 2

Reviewer 1 Report

All comments are addressed and look better now. 

Reviewer 2 Report

Corrections are well done