Next Article in Journal
Determination and Measurement of Melanopic Equivalent Daylight (D65) Illuminance (mEDI) in the Context of Smart and Integrative Lighting
Next Article in Special Issue
A Novel Equipment-Free Paper-Based Fluorometric Method for the Analytical Determination of Quinine in Soft Drink Samples
Previous Article in Journal
Experimental Demonstration of a Visible Light Communications System Based on Binary Frequency-Shift Keying Modulation: A New Step toward Improved Noise Resilience
Previous Article in Special Issue
Microbiological Quality Estimation of Meat Using Deep CNNs on Embedded Hardware Systems
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Field-Deployable Determinations of Peroxide Index and Total Phenolic Content in Olive Oil Using a Promising Portable Sensor System

by
Marco Grossi
1,2,*,
Alessandra Bendini
3,4,
Enrico Valli
3,4 and
Tullia Gallina Toschi
4,5
1
Department of Electrical Energy and Information Engineering “Guglielmo Marconi” (DEI), Alma Mater Studiorum—Università di Bologna, 40126 Bologna, Italy
2
Department of Physics and Astronomy “Augusto Righi” (DIFA), Alma Mater Studiorum—Università di Bologna, 40126 Bologna, Italy
3
Department of Agricultural and Food Sciences (DISTAL), Alma Mater Studiorum—Università di Bologna, 47521 Cesena, Italy
4
Interdepartmental Centre for Industrial Agrofood Research, Alma Mater Studiorum—Università di Bologna, 47521 Cesena, Italy
5
Department of Agricultural and Food Sciences (DISTAL), Alma Mater Studiorum—Università di Bologna, 40126 Bologna, Italy
*
Author to whom correspondence should be addressed.
Sensors 2023, 23(11), 5002; https://doi.org/10.3390/s23115002
Submission received: 26 April 2023 / Revised: 13 May 2023 / Accepted: 21 May 2023 / Published: 23 May 2023
(This article belongs to the Special Issue Innovative Sensors and Embedded Sensor Systems for Food Analysis)

Abstract

:
Useful information about the oxidative stability of a virgin olive oil in terms of oxidation products and antioxidant compounds can be obtained by analyzing the peroxide index (PI) and total phenolic content (TPC), respectively. These quality parameters are usually determined in a chemical laboratory using expensive equipment, toxic solvents, and well-trained personnel. This paper presents a novel portable sensor system for in the field and rapid determination of PI and TPC that is particularly suited in the case of small production environments that cannot afford an internal laboratory for quality control analysis. The system is small, can be powered by both USB ports and batteries, is easy to operate, and integrates a Bluetooth module for wireless data transmission. It estimates the PI and TPC in olive oil from the measurement of the optical attenuation of an emulsion between a reagent and the sample under test. The system has been tested on a set of 12 olive oil samples (eight for calibration and four for validation), and the results have shown how the considered parameters can be estimated with good accuracy. The maximum deviation from the results obtained with the reference analytical techniques is 4.7 meq O2/kg in the case of PI and 45.3 ppm in the case of TPC for the calibration set, while it is 14.8 meq O2/kg in the case of PI and 55 ppm in the case of TPC for the validation set.

1. Introduction

Olive oil is highly appreciated for its sensory attributes and beneficial effects on human health [1]. The quality of olive oil is defined by a set of parameters measured by chemical analyses as well as sensory analyses carried out by a panel of experts (the Panel test).
An important parameter that defines the quality of olive oil in terms of primary oxidative products is the peroxide index (PI), expressed as milliequivalents of active oxygen per kilogram of oil (meq O2/kg oil). If, during storage, the oil is exposed to light or the storage temperature is not adequate, oxidation is promoted, and the PI starts to increase [2]. On the other hand, very useful information can be taken from the total phenolic content (TPC) related to powerful antioxidants naturally present in virgin olive oils. In fact, phenolic compounds that act as free radical traps, contributing to protecting our body from some health diseases and providing anti-cancer activity [3], are also responsible for the product’s shelf life [4], as for the bitterness and pungency that are known as positive sensory characteristics of the product. The reference analytical techniques to measure PI and TPC in olive oil are manual titration [5] and liquid-liquid extraction followed by a spectrophotometric assay [6], respectively. These are chemical analyses that must be carried out in a laboratory by trained personnel using toxic solvents and standards. Moreover, the determination of TPC requires specific instrumentation and time-consuming procedures.
In the case of small olive oil mills and packaging centers that cannot afford an internal laboratory for quality control analyses, the sample to be tested must be shipped to an external laboratory, with high costs and a long response time. Thus, there is a need for rapid and low-cost solutions for the analysis of olive oil quality parameters that can be carried out in the field in a real production environment. In recent years, many field-deployable analytical approaches have been proposed for the quality and purity assessments of oils and fats. Some examples are: the determination of solid fat content in fats and oils by optical attenuation analysis [7,8]; the determination of iodine value of vegetable oils using a smartphone camera [9]; the measurement of total polyphenol concentration using a smartphone camera [10]; the quality analysis and determination of free acidity of olive oil using a portable sensor system [11,12]; the rapid detection of olive oil blends using a paper-based portable microfluidic platform [13]; the identification of edible oil storage period using a portable electronic nose [14]; the detection of food fraud in extra virgin olive oil using a portable hyphenated photonics sensor [15].
In this paper, a portable electronic sensor system for the determination of PI and TPC in olive oil is presented. The instrument is small, light-weighted, and battery-operated to allow in-field olive oil analysis. The instrument’s working principle is based on optical attenuation measurements of an emulsion of the oil sample with a chemical reagent. The portable sensor system has been tested outside a laboratory, and the results have shown a good correlation with the oil quality parameters determined by the reference analytical techniques.

2. Materials and Methods

2.1. Olive Oil Samples

The measurements have been carried out on a set of 12 olive oil samples (8 samples for calibration and 4 samples for validation), featuring a PI value that ranges from 5.3 to 31.9 meq O2/kg oil and a TPC value that ranges from 69.5 to 496.1 ppm.
For each investigated sample, PI and TPC have been determined by laboratory analysis using the reference methods. In the case of PI, the value has been determined according to the IOC and EU standard reference methods with starch as an indicator and sodium thiosulfate (Na2S2O3) as a titrant. In the case of TPC, the value has been determined according to the spectrophotometric assay based on the Folin–Ciocalteu reagent as proposed by Singleton and Rossi [16]. In particular, the phenolic fraction was extracted from the olive oil samples, and then, after the reaction with the specific reagent in alkaline medium, the phenolic content was detected at 750 nm and quantified, as reported in Reboredo-Rodrìguez et al. [17]. The values of PI and TPC determined with the reference methods have been used to evaluate the accuracy of the proposed embedded sensor system.

2.2. Solvents and Reagents

The reagents and chemicals used in this study, including methanol, sodium thiosulfate, Folin–Ciocalteu reagent, sodium carbonate, and ferrous oxidation-xylenol orange (FOX), were of analytical grade and were purchased from Sigma-Aldrich (St. Louis, MO, USA) or Merck (Readington, NJ, USA).

2.3. Measurement Principle

The olive oil parameters considered in this work, specifically peroxide index and total phenolic content, were estimated with the proposed portable sensor system using optical attenuation as the sensing principle. The olive oil under test was mixed with a suitable reagent to create an emulsion, and its optical attenuation was evaluated for a radiation source of known wavelength.
In the case of the peroxide index determination, the selected chemical chromophore is obtained by mixing 8 mL of FOX reagent with 7 mL of distilled water, and peroxides are detected according to the reaction:
F e 2 + + R O O H F e 3 + + R O + O H
where Fe3+ ions oxidize the dye xylenol orange, which produces a chromophore with strong absorption in the wavelength range around 580 nm.
In the case of the total phenolic content determination, the selected chemical reagent is obtained by mixing 13 mL of distilled water with 1 mL of Folin–Ciocalteu reagent and 1 mL of sodium carbonate Na2CO3 15%. In the presence of reducing compounds, such as the phenolic compounds, the acids present in the reagent are reduced to tungsten and molybdenum oxides, resulting in an optical attenuation in the wavelength range 500–900 nm with higher sensitivity in the near infrared wavelength range (680–900 nm).
Preliminary measurements were carried out using laboratory instrumentation to work out the optimal conditions in terms of radiation wavelength and reagent/oil sample ratio. An experimental setup was built, composed of a Falcon vial containing the emulsion, a LED, and a photodiode. The LED was supplied with a square-wave voltage using a benchtop function generator (Agilent 33210A, Agilent Technologies, Santa Clara, CA, USA), and the current through the photodiode was converted to voltage and acquired using a National Instruments data acquisition device (USB-6003, National Instruments, Austin, TX, USA). LabVIEW programs were developed to acquire, process, and save the measured data on the PC hard disk for further analysis. In the case of peroxide index determination, the reaction of FOX reagent with peroxide compounds produces a strong absorption peak between 550 and 600 nm [18]. LEDs with different wavelength peaks (560, 570, 580, 590, and 600 nm) were tested, and the best results were obtained in the case of peak wavelength 590 nm. Different reagent/sample ratios were also tested (0.5, 1, 2, and 5 mL of sample in 15 mL of reagent), and the best result was obtained in the case of 0.5 mL of olive oil. Similarly, in the case of total phenolic content determination, the reaction of the Folin–Ciocalteu reagent with phenolic compounds produces a strong absorption in the wavelength range 680–900 nm [19]. LEDs with different wavelength peaks (700, 750, 800, 850, and 900 nm) and different reagent/sample ratios (0.5, 1, 2, and 5 mL of sample in 15 mL of reagent) were tested, and the best results were obtained in the case of an LED with a peak wavelength of 850 nm and 0.5 mL of olive oil.
In the following, the emulsion was created by mixing 15 mL of the reagent with 0.5 mL of the olive oil under test.

2.4. Portable Sensor System

The portable sensor system for in the field determination of peroxide index and total phenolic content is presented in Figure 1. It is composed of a plastic case (11 cm × 15 cm × 5 cm) integrated with four buttons for user interaction and a 16 × 2 LCD display, a Polylactic Acid (PLA) structure (built with a 3D printer, MakerBot Replicator Z18, MakerBot Industries, New York City, NY, USA) devoted to hosting the vial with the emulsion as well as the LEDs and photodiodes, and an electronic board, designed by the research team using KiCad 5.1.2 [20], to control the LEDs and measure the currents in the photodiodes.
The PLA structure built with the 3D printer is presented in Figure 2. The vial containing the emulsion to be analyzed is hosted in a cylindrical cavity, and two couples of LEDs/photodiodes are integrated in the structure for the optical attenuation measurements. The LED generates the radiation that is transmitted through the emulsion, and the attenuated radiation emerging from the emulsion is detected by the photodiode. In the case of peroxide index measurements, the visible LED with a peak wavelength of 590 nm and the photodiode (BPW21R, Vishay Intertechnology, Malvern, PA, USA) with a wavelength sensitivity range of 420–675 nm is used. In the case of total phenolic content measurements, the near-infrared (NIR) LED with a peak wavelength of 850 nm and the photodiode (OSD5-5T, Centronic, Croydon, UK) with a wavelength sensitivity range of 430–900 nm is used.
The designed electronic board is based on the 32 bit low-power microcontroller STM32L152VCT6 by ST Microelectronics and integrates a Bluetooth class-2 module (SPBT2632C2A by ST-Microelectronics, Geneva, Switzerland) that allows wireless data transmission in addition to data presentation on the LCD display and wired data transmission using the USB port.
The procedure for olive oil analysis using the proposed sensor system is presented in the flowcharts in Figure 3a,b. When the system is powered on, if button 1 is pressed, the system enters a calibration procedure where the LED intensity is changed to produce a target output value in the case of an empty vial. The value of the LED intensity is then stored on an EEPROM memory integrated in the microcontroller. Then, the system waits for the user to select the action (button 2: measurement of PI; button 3: measurement of TPC; and button 4: power off the system). After the selection, the measurement is carried out, and the results are displayed on the LCD screen. The procedure for a single measurement is presented in the flowchart in Figure 3b. Initially, the LCD screen informs the user to insert a vial with only the reagent, and a measurement of the optical attenuation is carried out to check that the optical properties of the reagent are correct (i.e., the reagent is not degraded). Then, the system asks the user to insert the vial with the emulsion created with the reagent and the oil (the procedure is discussed in Section 2.3), and measurements of optical attenuation are carried out at time intervals of 5 s for a total time of 900 s (15 min). Then, the oil parameter of interest is estimated on the measured value at a particular time (600 s for PI and 500 s for TPC, as will be discussed in Section 3), and such a value is displayed on the LCD screen. Even if the system estimates the quality parameter of interest based on the measurement at a fixed time, the entire dataset (optical attenuation vs. time) is recorded and can be downloaded to a PC for further data processing.
The circuit for the measurement of the emulsion’s optical attenuation is shown in Figure 4. The chip AS1101 (ams-OSRAM AG, Premstaetten, Austria, EU) is an LED driver used to control the two LEDs used in the system. The analog input CTRL is generated using the 12 bit DAC integrated in the microcontroller and used to control the intensity of the current flowing in the LED when in the ON state. The input ON is fed with a PWM signal (frequency 1 kHz, duty-cycle 50%) generated by the microcontroller to drive the LED ON and OFF according to the PWM signal. The LED generates a pulse of light with a frequency of 1 kHz that is transmitted through the vial containing the emulsion. The light emerging from the vial is detected by the photodiode, which generates a pulsed current that is then converted to voltage, amplified with the programmable instrumentation amplifier AD8231ACPZ (Analog Devices, Wilmington, MA, USA) and filtered using a Sallen–Key low-pass filter with a cutoff frequency of 32 kHz. The circuit has been simulated using LTSpice XVII by Analog Devices [21], and the signal waveforms are presented in Figure 5.

2.5. Statistical Analysis

The measured data have been processed using Microsoft Excel 2010 and its statistical add-on package, XLSTAT 2016. The olive oil quality parameters of interest (PI and TPC) have been estimated by fitting the light attenuation values measured by the sensor system with the quality parameters determined using reference laboratory techniques.
The accuracy of the estimated values of quality parameters has been evaluated using the mean square error (MSE), which gives information on the mean quadratic discrepancy between the values obtained with the reference techniques and the values predicted with the proposed sensor system. MSE can be calculated with the following equation:
M S E = 1 N × i = 1 N Y i X i 2
where N is the number of tested samples, Yi is the estimated quality parameter for sample i, and Xi is the quality parameter obtained with the reference techniques for sample i.

3. Results and Discussion

3.1. Determination of the Optimal Measurement Time

A set of eight olive oil samples has been used to calibrate the proposed portable instrument after the analytical parameters (PI and TPC) of each sample have been determined using the reference laboratory techniques. The intensity of the radiation transmitted through the emulsion has been monitored at time intervals of 5 s for a total of 900 s. The results are presented in Figure 6 and Figure 7 for the PI and TPC, respectively, in the case of all 8 samples. In the figures, the intensity of the transmitted radiation is reported with the parameter DOUT, which represents the digital value (between 0 and 4095) of the peak-to-peak voltage of the signal VOUT in Figure 4 when measured with the 12 bit ADC integrated in the microcontroller.
As can be seen, for both PI and TPC measurements, the intensity of the transmitted light presents a rapid change in the first minutes after the emulsion creation and then tends to saturate after 9–10 min. These are the results of the reaction between the chemical reagent and the olive oil under test, which took some time to complete.
To evaluate the best trade-off between measurement speed and accuracy in the estimation of quality parameters, different measurement times (0 s, 100 s, 200 s, 300 s, 400 s, 500 s, and 600 s) have been considered and the corresponding parameters estimated in each case. Measurement times higher than 600 s are not considered since we have defined 10 min as the maximum reasonable measurement time for quick in the field olive oil analysis. Moreover, we have checked that the potential improvement in accuracy due to longer measurements is negligible and lower than the uncertainty associated with repeated measurements. Then, the accuracy of the estimation is evaluated using the MSE parameter. The MSE parameter is calculated as follows: for each measurement time, the calibration equation that correlates the optical attenuation data with the quality parameter of interest determined with the reference technique is calculated, and such a calibration equation is used to estimate the values of the quality parameter of interest. Then, the MSE value is calculated from the analytical parameter determined with the reference technique and its estimated value using Equation (2). The results are presented in Table 1. As can be seen, MSE strongly decreases with measurement time in the first 5 min (300 s) and then slightly decreases and saturates. The best accuracy (i.e., lowest value of MSE) is obtained after 600 s for PI and after 500 s for TPC. Thus, in the following, the olive oil parameters have been determined from the value of DOUT measured at 600 s for PI and at 500 s for TPC.

3.2. Accuracy of the Estimated Quality Parameters

The value of DOUT for the target measurement time (600 s for PI and 500 s for TPC) has been plotted vs. the corresponding parameter determined with the reference technique for each olive oil sample from the calibration set. The results are presented in Figure 8 for the measurement of PI and in Figure 9 for the measurement of TPC.
As can be seen in Figure 8, the value of DOUT at 600 s presents a linear correlation with the PI determined using the reference technique, and the corresponding calibration equation is defined by the following:
PI = 10 3 × D O U T / 4096 0.893 8.531
and the determination coefficient is R2 = 0.872.
In the case of TPC measurements, instead, the correlation between DOUT at 500 s and the TPC value determined with the reference technique is logarithmic, as can be seen in Figure 9, and the corresponding calibration equation (R2 = 0.924) is defined by the following:
TPC = 10 4 × log 10 D O U T / 4096 3.138 × 10 3 4.994
The calibration Equations (3) and (4) have been used to estimate the values of PI and TPC, and such values (mean value and error from triplicate measurements) have been compared with the results of the reference techniques in Table 2 and Table 3, respectively.
As can be seen, in both cases, the estimated value features good accuracy. In particular, in the case of PI measurements, the maximum deviation between the mean value calculated with the proposed system and the reference analytical protocol is 4.7 meq O2/kg oil, and all investigated samples are classified in the same quality category as defined by the reference method (the threshold value for edible virgin olive oil is 20 meq O2/kg). In fact, as reported in Table 2, for the proposed and reference methods, the same quality grade is defined, specifically the samples coded three, six, and eight are classified as lampante olive oil or not edible instead of the other five samples as edible olive oil (being the same limit fixed for both extra virgin and virgin quality grades).
In the case of TPC measurements, the maximum deviation between the value calculated with the proposed system and the reference technique is 45.3 ppm, and the proposed system is able to detect the usual concentration range of phenolic compounds in the oil [22]. Specifically, the samples coded as three and six are characterized by a low content of phenolic compounds (below 200 mg per kg of oil) for both methods, as are other samples with a medium content (ranging from 200 to 500 mg per kg of oil).
To investigate the effect of matrix variations among different olive oils on the accuracy of the estimated quality parameters, the equations obtained with the calibration group of eight olive oil samples have been used to estimate the analytical parameters on a different set of four olive oil samples. The results are presented in Table 4 for the PI and in Table 5 for the TPC.
As can be seen in Table 4, all validation samples are classified in the same quality category as defined by the reference method (edible virgin olive oil with a PI < 20 meq O2/kg for samples A, B, and C and lampante olive oil with a PI > 20 meq O2/kg for sample D). In the case of sample D, there is a significant overestimation of PI that could be explained by the presence of interfering compounds from secondary oxidation.
Similarly, for the case of TPC, shown in Table 5, the concentration range of phenolic compounds is correctly estimated for all samples (low content of phenolic compounds for samples A and D and medium content of phenolic compounds for samples B and C).

4. Conclusions

The paper presents a novel sensor system for the estimation of peroxide index (PI) and total phenolic content (TPC) in virgin olive oils. The sensor system is of small size, easy to operate, can be powered using a USB port or batteries, and integrates a Bluetooth module for wireless data transfer. It estimates the parameters of interest by measuring the optical attenuation of an emulsion between a chemical reagent and the olive oil sample.
The proposed system is particularly interesting in the case of olive oil mills and small packaging centers that cannot afford an internal laboratory for quality control analysis. It can perform measurements in the field and be used by operators without specific training.
The sensor system has been tested on a set of 12 olive oil samples (eight for calibration and four for validation) featuring different values of the quality parameters. The results have shown that accurate determination of PI and TPC is feasible. The maximum deviation from the results obtained with the reference techniques is 4.7 meq O2/kg in the case of PI and 45.3 ppm in the case of TPC for the calibration set, while it is 14.8 meq O2/kg in the case of PI and 55 ppm in the case of TPC for the validation set. To confirm the herein presented promising results, a set composed of a higher number of olive oils will be assessed.

Author Contributions

Conceptualization, M.G., E.V. and A.B.; methodology, M.G. and A.B.; software, M.G.; validation, M.G. and A.B.; investigation, M.G. and A.B.; resources, M.G., E.V. and A.B.; data curation, M.G., E.V. and A.B.; writing—original draft preparation, M.G.; writing—review and editing, M.G., E.V., A.B. and T.G.T.; supervision, T.G.T.; project administration, T.G.T. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Tulipani, S.; Huelamo, M.M.; Ribalta, M.R.; Estruch, R.; Ferrer, E.E.; Andres-Lacueva, C.; Montserrat Illan, R.; Lamuela-Raventós, R.M. Oil matrix effects on plasma exposure and urinary excretion of phenolic compounds from tomato sauces: Evidence from a human pilot study. Food Chem. 2012, 130, 581–590. [Google Scholar] [CrossRef]
  2. Kalua, C.M.; Bedgood, D.R.; Bishop, A.G.; Prenzler, P.D. Discrimination of storage conditions and freshness in virgin olive oil. J. Agric. Food Chem. 2006, 54, 7144–7151. [Google Scholar] [CrossRef] [PubMed]
  3. Notarnicola, M.; Pisanti, S.; Tutino, V.; Bocale, D.; Rotelli, M.T.; Gentile, A.; Memeo, V.; Bifulco, M.; Perri, E.; Caruso, M.G. Effects of olive oil polyphenols on fatty acid synthase gene expression and activity in human colorectal cancer cells. Genes Nutr. 2011, 6, 63–69. [Google Scholar] [CrossRef] [PubMed]
  4. Lerma-García, M.J.; Simo-Alfonso, E.F.; Chiavaro, E.; Bendini, A.; Lercker, G.; Cerretani, L. Study of chemical changes produced in virgin olive oils with different phenolic contents during an accelerated storage treatment. J. Agric. Food Chem. 2009, 57, 7834–7840. [Google Scholar] [CrossRef] [PubMed]
  5. International Olive Council. COI/T.20/Doc. No. 35/Rev. 1—Determination of Peroxide Value—Decision DEC-III-12/106-VI/2017. Available online: https://www.internationaloliveoil.org/what-we-do/chemistry-standardisation-unit/standards-and-methods/ (accessed on 12 May 2023).
  6. Tasioula-Margari, M.; Okogeri, O. Isolation and characterization of virgin olive oil phenolic compounds by HPLC/UV and GC-MS. J. Food Sci. 2001, 66, 530–534. [Google Scholar] [CrossRef]
  7. Grossi, M.; Valli, E.; Glicerina, V.T.; Rocculi, P.; Gallina Toschi, T.; Riccò, B. Practical determination of solid fat content in fats and oils by single-wavelength near-infrared analysis. IEEE Trans. Instrum. Meas. 2019, 69, 585–592. [Google Scholar] [CrossRef]
  8. Grossi, M.; Valli, E.; Glicerina, V.T.; Rocculi, P.; Gallina Toschi, T.; Riccò, B. Optical Determination of Solid Fat Content in Fats and Oils: Effects of Wavelength on Estimated Accuracy. Eur. J. Lipid Sci. Technol. 2022, 124, 2100071. [Google Scholar] [CrossRef]
  9. Peamaroon, N.; Jakmunee, J.; Moonrungsee, N. A Simple Colorimetric Procedure for the Determination of Iodine Value of Vegetable Oils Using a Smartphone Camera. J. Anal. Test. 2021, 5, 379–386. [Google Scholar] [CrossRef]
  10. Calabria, D.; Mirasoli, M.; Guardigli, M.; Simoni, P.; Zangheri, M.; Severi, P.; Caliceti, C.; Roda, A. Paper-based smartphone chemosensor for reflectometric on-site total polyphenols quantification in olive oil. Sens. Actuators B Chem. 2020, 305, 127522. [Google Scholar] [CrossRef]
  11. Grossi, M.; Palagano, R.; Bendini, A.; Riccò, B.; Servili, M.; García-González, D.L.; Gallina Toschi, T. Design and in-house validation of a portable system for the determination of free acidity in virgin olive oil. Food Control 2019, 104, 208–216. [Google Scholar] [CrossRef]
  12. Grossi, M.; Valli, E.; Bendini, A.; Gallina Toschi, T.; Riccò, B. A Portable Battery-Operated Sensor System for Simple and Rapid Assessment of Virgin Olive Oil Quality Grade. Chemosensors 2022, 10, 102. [Google Scholar] [CrossRef]
  13. Radovanović, M.; Ilić, M.; Pastor, K.; Ačanski, M.; Panić, S.; Srdić, V.V.; Randjelović, D.; Kojić, T.; Stojanović, G.M. Rapid detection of olive oil blends using a paper-based portable microfluidic platform. Food Control 2021, 124, 107888. [Google Scholar] [CrossRef]
  14. Jiang, H.; He, Y.; Chen, Q. Qualitative identification of the edible oil storage period using a homemade portable electronic nose combined with multivariate analysis. J. Sci. Food Agric. 2021, 101, 3448–3456. [Google Scholar] [CrossRef] [PubMed]
  15. Weesepoel, Y.; Alewijn, M.; Wijtten, M.; Müller-Maatsch, J. Detecting food fraud in extra virgin olive oil using a prototype portable hyphenated photonics sensor. J. AOAC Int. 2021, 104, 7–15. [Google Scholar] [CrossRef] [PubMed]
  16. Singleton, V.L.; Rossi, J.A. Colorimetry of total phenolics with phosphomolibdic-phosphotungstic acid reagents. Am. J. Enol. Viticul. 1965, 16, 144–158. [Google Scholar] [CrossRef]
  17. Reboredo-Rodríguez, P.; Valli, E.; Bendini, A.; Di Lecce, G.; Simal-Gándara, J.; Gallina Toschi, T. A widely used spectrophotometric assay to quantify olive oil biophenols according to the health claim (EU Reg. 432/2012). Eur. J. Lipid Sci. Technol. 2016, 118, 1593–1599. [Google Scholar] [CrossRef]
  18. Meisner, P.; Gebicki, J.L. Determination of hydroperoxides in aqueous solutions containing surfactants by the ferrous oxidation-xylenol orange method. Acta Biochim. Pol. 2009, 56, 523–527. [Google Scholar] [CrossRef] [PubMed]
  19. Kamboj, A.; Gupta, R.; Rana, A.; Kaur, R. Application and analysis of the Folin Ciocalteu method for the determination of the total phenolic content from extracts of Terminalia bellerica. Eur. J. Biomed. Pharm. Sci. 2015, 2, 201–215. [Google Scholar]
  20. KiCAD. Electronic Design Automation Suite. Available online: https://www.kicad.org/ (accessed on 7 February 2023).
  21. LTSpice Circuit Simulator Software. Available online: https://www.analog.com/en/design-center/design-tools-and-calculators/ltspice-simulator.html (accessed on 7 February 2023).
  22. Montedoro, G.; Servili, M.; Baldioli, M.; Miniati, E. Simple and hydrolyzable phenolic compounds in virgin olive oil. 1. Their extraction, separation, and quantitative and semiquantitative evaluation by HPLC. J. Agric. Food Chem. 1992, 40, 1571–1576. [Google Scholar] [CrossRef]
Figure 1. Picture of the proposed portable sensor system for the determination of peroxide index and total phenolic content in olive oil.
Figure 1. Picture of the proposed portable sensor system for the determination of peroxide index and total phenolic content in olive oil.
Sensors 23 05002 g001
Figure 2. Picture of the PLA structure devoted to the host of the emulsion and the LEDs/photodiodes used for the optical attenuation measurements.
Figure 2. Picture of the PLA structure devoted to the host of the emulsion and the LEDs/photodiodes used for the optical attenuation measurements.
Sensors 23 05002 g002
Figure 3. Flowchart of the general procedure for olive oil analysis (a) and single measurement steps (b) using the proposed sensor system.
Figure 3. Flowchart of the general procedure for olive oil analysis (a) and single measurement steps (b) using the proposed sensor system.
Sensors 23 05002 g003
Figure 4. Schematic of the circuit for the optical attenuation measurements.
Figure 4. Schematic of the circuit for the optical attenuation measurements.
Sensors 23 05002 g004
Figure 5. Waveforms of the signals of the circuit for the optical attenuation measurements obtained with LTSpice simulations.
Figure 5. Waveforms of the signals of the circuit for the optical attenuation measurements obtained with LTSpice simulations.
Sensors 23 05002 g005
Figure 6. Values of the intensity of the radiation transmitted through the emulsion plotted vs. time in the case of peroxide index measurements.
Figure 6. Values of the intensity of the radiation transmitted through the emulsion plotted vs. time in the case of peroxide index measurements.
Sensors 23 05002 g006
Figure 7. Values of the intensity of the radiation transmitted through the emulsion plotted vs. time in the case of total phenolic content measurements.
Figure 7. Values of the intensity of the radiation transmitted through the emulsion plotted vs. time in the case of total phenolic content measurements.
Sensors 23 05002 g007
Figure 8. System response after 600 s plotted vs. the olive oil PI determined with the reference method.
Figure 8. System response after 600 s plotted vs. the olive oil PI determined with the reference method.
Sensors 23 05002 g008
Figure 9. System response after 500 s plotted vs. the olive oil TPC determined with the reference method.
Figure 9. System response after 500 s plotted vs. the olive oil TPC determined with the reference method.
Sensors 23 05002 g009
Table 1. MSE values for different measurement times in the case of PI and TPC determination of the olive oil sample set.
Table 1. MSE values for different measurement times in the case of PI and TPC determination of the olive oil sample set.
Measurement Type0 s100 s200 s300 s400 s500 s600 s
Peroxide index98.931.821.617.513.512.611.7
Total phenolic content3403.72493.32046.21840.31725.81699.01723.7
Table 2. Olive oil peroxide index values (expressed in meq O2/kg) estimated with the proposed system and obtained with the reference technique in the case of the calibration set of eight olive oil samples.
Table 2. Olive oil peroxide index values (expressed in meq O2/kg) estimated with the proposed system and obtained with the reference technique in the case of the calibration set of eight olive oil samples.
Olive Oil SamplePI (Proposed Sensor System)PI (Reference Technique)
#13.0 ± 1.95.3 ± 0.4
#215.7 ± 1.515.9 ± 1.1
#330.2 ± 2.728.4 ± 2.0
#48.2 ± 1.77.0 ± 0.5
#513.1 ± 1.717.8 ± 1.2
#627.7 ± 0.523.9 ± 1.7
#713.9 ± 4.514.6 ± 1.0
#829.9 ± 1.731.9 ± 2.2
Table 3. Olive oil total phenolic content values (expressed in ppm) estimated with the proposed system and obtained with the reference technique in the case of the calibration set of eight olive oil samples.
Table 3. Olive oil total phenolic content values (expressed in ppm) estimated with the proposed system and obtained with the reference technique in the case of the calibration set of eight olive oil samples.
Olive Oil SampleTPC (Proposed Sensor System)TPC (Reference Technique)
#1443.5 ± 18.0483.1 ± 19.3
#2261.8 ± 2.4274.2 ± 11.0
#3105.0 ± 12.2141.5 ± 5.7
#4440.6 ± 50.0408.1 ± 16.3
#5294.1 ± 11.4310.8 ± 12.4
#675.9 ± 11.869.5 ± 2.8
#7497.2 ± 5.4496.1 ± 19.8
#8297.3 ± 20.0251.9 ± 10.1
Table 4. Olive oil peroxide index values (expressed in meq O2/kg) estimated with the proposed system and obtained with the reference technique in the case of the validation set of four olive oil samples (A–D).
Table 4. Olive oil peroxide index values (expressed in meq O2/kg) estimated with the proposed system and obtained with the reference technique in the case of the validation set of four olive oil samples (A–D).
Olive Oil SamplePI (Proposed Sensor System)PI (Reference Technique)
#A4.1 ± 1.57.6 ± 0.5
#B10.3 ± 2.117.8 ± 1.2
#C17.2 ± 1.815.9 ± 1.1
#D45.8 ± 5.631.0 ± 2.2
Table 5. Olive oil total phenolic content values (expressed in ppm) estimated with the proposed system and obtained with the reference technique in the case of the validation set of four olive oil samples (A–D).
Table 5. Olive oil total phenolic content values (expressed in ppm) estimated with the proposed system and obtained with the reference technique in the case of the validation set of four olive oil samples (A–D).
Olive Oil SampleTPC (Proposed Sensor System)TPC (Reference Technique)
#A124.2 ± 12.3140.5 ± 5.6
#B421.7 ± 23.7387.4 ± 15.5
#C229.8 ± 7.4229.9 ± 9.2
#D120.4 ± 9.8175.4 ± 7.0
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Grossi, M.; Bendini, A.; Valli, E.; Gallina Toschi, T. Field-Deployable Determinations of Peroxide Index and Total Phenolic Content in Olive Oil Using a Promising Portable Sensor System. Sensors 2023, 23, 5002. https://doi.org/10.3390/s23115002

AMA Style

Grossi M, Bendini A, Valli E, Gallina Toschi T. Field-Deployable Determinations of Peroxide Index and Total Phenolic Content in Olive Oil Using a Promising Portable Sensor System. Sensors. 2023; 23(11):5002. https://doi.org/10.3390/s23115002

Chicago/Turabian Style

Grossi, Marco, Alessandra Bendini, Enrico Valli, and Tullia Gallina Toschi. 2023. "Field-Deployable Determinations of Peroxide Index and Total Phenolic Content in Olive Oil Using a Promising Portable Sensor System" Sensors 23, no. 11: 5002. https://doi.org/10.3390/s23115002

APA Style

Grossi, M., Bendini, A., Valli, E., & Gallina Toschi, T. (2023). Field-Deployable Determinations of Peroxide Index and Total Phenolic Content in Olive Oil Using a Promising Portable Sensor System. Sensors, 23(11), 5002. https://doi.org/10.3390/s23115002

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop