Next Article in Journal
Emerging MIMO Technologies for 6G Networks
Next Article in Special Issue
Emergency Management in the Event of Radiological Dispersion in an Urban Environment
Previous Article in Journal
Modeling and Parameter Identification of a 3D Measurement System Based on Redundant Laser Range Sensors for Industrial Robots
Previous Article in Special Issue
Neutron and Gamma-Ray Detection System Coupled to a Multirotor for Screening of Shipping Container Cargo
 
 
Perspective
Peer-Review Record

Sievert or Gray: Dose Quantities and Protection Levels in Emergency Exposure

Sensors 2023, 23(4), 1918; https://doi.org/10.3390/s23041918
by Chiara Ferrari 1,*, Guglielmo Manenti 2 and Andrea Malizia 2
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Sensors 2023, 23(4), 1918; https://doi.org/10.3390/s23041918
Submission received: 15 October 2022 / Revised: 1 February 2023 / Accepted: 3 February 2023 / Published: 8 February 2023

Round 1

Reviewer 1 Report

Reviewer comments for authors:

The authors analyzed the application of new operational quantities according to ICRU 95 recommendations.
Shorten the Introduction to avoid unnecessary repetition.

Table 1 refers to data from ICRP103, not 107 as stated on page 4.

Most of the tables are robust, so I suggest the authors reorganize the text and move those Tables to an appendix.

Please cite the article of M. Caresana et al. titled as “Impact of new operational dosimetric

quantities on individual monitoring services” published in J. Radiol. Prot.( 41 (2021) 1110–1121).

 



Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

Dear authors,

The submitted manuscript presents a review of the latest scientific reports of international bodies regarding dose values physical quantities, however I have some concerns, expressed below in the form of comments.

Comment 1. There is not any new information in the submitted manuscript. As such I cannot consider it as a research paper. However, it is might be a useful review paper. Please stress the word "review" in the abstract and introduction section.

Comment 2. Abstract the authors state that "But during an emergency, it could not fit for the scope because tissue effects can take place, and they are quantified with the Gray unit.". Tissue effects are considered through wT and this is the sievert unit, since emergency effects are usually whole-body effects. Of course in special cases, as mentioned in the anuscript, the RBE may be considered. The authors are kindly asked to rewrite the sentence.

Comment 3.The authors state that "The aim is not to introduce further difficulties in changing measure units, as should be expected when dealing with acute exposure. The aim is not to introduce further difficulties in changing measure units, as it should" Please re write these sentences, it seems like a repetitiion.

Comment 4. References at the sentences end of Table 4 and 5 legends. Reference 9 is the EU council directive not the IAEA. Please correct appropriately.

Comment 5. The authors should insert information (eg a table or text) with examples that may be considered an emergency   

with kind regards

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Round 2

Reviewer 2 Report

Dear authors

I am OK with your corrections

thank you

Back to TopTop