Article

Yb2+-Doped Silicate Glasses as Optical Sensor Materials for Cryogenic Thermometry

Univ. Lille, CERLA, CNRS, UMR 8523-PhLAM-Physique des Lasers Atomes et Molécules, F-59000 Lille, France
*
Author to whom correspondence should be addressed.
Sensors 2024, 24(1), 248; https://doi.org/10.3390/s24010248
Submission received: 7 December 2023 / Revised: 22 December 2023 / Accepted: 25 December 2023 / Published: 31 December 2023

Abstract

:
Optical sensors constitute attractive alternatives to resistive probes for the sensing and monitoring of temperature (T). In this work, we investigated, in the range from 2 to 300 K, the thermal behavior of Yb2+ ion photoluminescence (PL) in glass hosts for cryogenic thermometry. To that end, two kinds of Yb2+-doped preforms, with aluminosilicate and aluminophosphosilicate core glasses, were made using the modified chemical vapor deposition (MCVD) technique. The obtained preforms were then elongated, at about 2000 °C, to canes with an Yb2+-doped core of about 500 µm. Under UV excitation and independently of the core composition, all samples of preforms and their corresponding canes presented a wide visible emission band attributed to Yb2+ ions. Furthermore, PL kinetics measurements, recorded at two emission wavelengths (502 and 582 nm) under 355 nm pulsed excitation, showed an increase, at very low T, followed by a decrease in lifetime until room temperature (RT). A modified two-level model was proposed to interpret such a decay time dependence versus T. Based on the fit of lifetime data with this model, the absolute (Sa) and relative (Sr) sensitivities were determined for each sample. For both the preform and its corresponding cane, the aluminophosphosilicate glass composition featured the highest performances in the cryogenic domain, with values exceeding 28.3 µsK−1 and 94.4% K−1 at 30 K for Sa and Sr, respectively. The aluminophosphosilicate preform also exhibited the wider T operating range of 10–300 K. Our results show that Yb2+-doped silicate glasses are promising sensing materials for optical thermometry applications in the cryogenic domain.

1. Introduction

Due to the high optical conversion efficiency of trivalent ytterbium ions (Yb3+) in the near-infrared (NIR) domain, Yb3+-activated silicate glasses are among the most interesting luminescent materials [1]. Moreover, compared to their crystalline counterpart, these glassy materials show higher mechanical and thermal stabilities, enabling their drawing and shaping as optical fibers. This made the development of high-power fiber lasers possible for several applications, including materials processing, medicine and telecommunications [2,3]. In addition, in silicate matrices, ytterbium ions can also exist in a divalent state (Yb2+). The relative concentration of both kind of ions within the host material largely depends on the oxidizing/reducing conditions during the material fabrication [4]. However, although Yb2+ ions present an interesting visible photoluminescence (PL) under UV excitation, their presence could be critical for laser applications [5,6]. This could explain why this visible optical activity of Yb2+ ions has hardly been studied in glasses and was limited, at RT, to white light source applications [7]. In the field of temperature sensing, and for applications where conventional thermometry is difficult to implement, it is required to monitor the temperature in volume-restricted areas. This has prompted the development of remote temperature measurement methods based on optical fibers [8]. The former offer key advantages compared to conventional sensors: small size, flexibility, intrinsic immunity to electromagnetic interference and their ability for remote interrogation. Among the luminescence-based techniques, lifetime thermometry is commonly used, as it is not sensitive to external factors, such as excitation fluctuations, obviating the need for intensity referencing and, thus, minimizing the associated errors [9]. Based on this approach, Yb3+-activated optical fibers have demonstrated their potential as probing materials for thermometric applications from RT to 973 K [10]. Nevertheless, Yb3+ ions are less suitable for lower temperature sensing due to the small change in their lifetime with temperature, particularly in the cryogenic domain [10,11]. On the other hand, for thermometry in this domain, until now, investigations have concerned mainly Yb2+ ions in fluorite-type crystals such as CaF2 and SrF2. Indeed, the fluorescence decay time of such Yb2+-doped materials is temperature-sensitive above all in the cryogenic range [12]. The association of such crystalline materials with optical fibers has led to cryogenic temperature punctual sensors in the 20–120 K range [13]. Hitherto, to the best of our knowledge, the thermal behavior of Yb2+ ion fluorescence in silicate glass matrices has not been investigated for cryogenic thermometry. Furthermore, from the perspective of further reducing the sensing material size and thus increasing its spatial resolution without interfering with the measured object itself, an alternative to the use of a crystalline material at the end of an optical fiber could be the use of a more compatible active glassy one. Therefore, the size of the sensing material could be easily adjusted by drawing and then connecting to a transport optical fiber by conventional glass fusion splicing. This also offers, in the case of small, measured objects, the possibility to use the sensor while keeping the temperature in equilibrium during the measurement. In order to reach this advanced stage in development, upstream investigations are needed. Hence, in this paper, Yb2+-doped silicate optical preforms were prepared using the MCVD method in reducing conditions. The obtained preforms were also elongated, at about 2000 °C, to canes with Yb2+-doped cores of about 500 µm. The thermal behavior of Yb2+ ion luminescence, under UV excitation, has been evaluated in the temperature range of 2–300 K.

2. Materials and Methods

Yb-doped aluminophosphosilicate (YAPS) and aluminosilicate (YAS) optical preforms were fabricated, using the MCVD process in combination with the solution doping (SD) technique, at the FiberTech Lille platform (PhLAM laboratory, Lille, France). Initially, a pure silica tube (F300, Heraeus, Hanau, Germany) was mounted on MCVD lathe. Then, this tube was etched by inside flowing of C2F6, O2 and He gases to clean up its inner wall at 1900 °C. Subsequently, one sintered barrier layer of pure silica was deposited there, using SiCl4 with O2 at 2000 °C, followed by the deposition of one non-sintered silica soot layer at 1690 °C applying a gaseous flow of SiCl4 with O2 and He. After cooling, the tube was maintained under a controlled atmosphere and placed for vertical SD using a solution of YbCl3 in ethanol, along with AlCl3·6H2O for the YAS composition. In the case of the YAPS ones, we used a solution of diluted phosphoric acid, along with AlCl3·6H2O and YbCl3. The soot layers were soaked for 40 min, and after the impregnation, the solution was drained out and the tube was fixed vertically and kept in a controlled neutral atmosphere for drying. Afterward, the tube was mounted on an MCVD lathe and dried again by a flow of a hot mixture of Cl2 and He gases around 1000 °C. Then, a stepwise sintering to sealing was done in full H2/Ar atmosphere with an increasing temperature from 1700 °C to 2150 °C.
The Yb-doped glassy preforms were drawn at a temperature of about 2000 °C down to a millimeter-sized cane with doped core of about 500 µm. The fabricated preforms and their corresponding drawn canes were cut and polished for optical characterizations.
UV–Visible absorption spectra were obtained at room temperature using a Cary 5000 double-beam spectrophotometer (Agilent, Santa Clara, CA, USA).
PL measurements in the temperature range of 2–300 K were achieved in the closed cycle magneto optical cryostat SpectromagPT (Oxford Instruments, Oxford, UK). The time-resolved PL spectra and PL decay kinetics were recorded under 355 nm pulsed excitation in the photon-counting regime with the use of a single-grating monochromator M266 (Solar LS) equipped with a thermoelectrically cooled GaAs(Cs) photomultiplier R943-02 (Hamamatsu Inc., Hamamatsu City, Japan) and multistop scaler P7887 (FAST ComTec GmbH, Oberhaching, Germany) with a time resolution up to 250 ps. The pulsed source of excitation at 355 nm was the pump laser integrated into the optical parametric oscillator (OPO) Opolette 355 LD (Opotek Inc., Carlsbad, CA, USA), with a tunable repetition rate (up to 100 Hz) and 8 ns pulse duration.

3. Results and Discussion

Figure 1 shows the optical absorption spectra of the YAPS and YAS preforms. They present, in the UV–Visible range (Figure 1a), three bands peaking at 240, 330 and 400 nm. The bands around 330 nm and 400 nm are due to divalent Yb2+ ions and originate from the 4f14→4f135d transitions. These attributions are based on comparisons with similar absorption bands reported in the case of Yb/Al/P- and Yb/Al-doped silica glasses [4,14]. The last one centered at 240 nm can be assigned to charge transfer transitions between the Yb3+ ion and the oxygen ligands in the glass network [5,14]. In addition, the absorption bands shown in Figure 1b, in the NIR wavelength range of 825–1100 nm, are assigned to the 2F7∕22F5∕2 transitions of Yb3+ ions [4]. Therefore, both Yb2+ and Yb3+ ions coexisted in our YAPS and YAS samples.
From the value of absorption at the wavelength of 977 nm, the concentration of Yb3+ ions could be estimated using the absorption cross-section reported in the literature for Yb-doped aluminophosphosilicate and aluminosilicate glasses [15]. Moreover, based on the mean Yb concentration determined from the electron probe microanalysis (EPMA), the concentration of Yb2+ ions was also evaluated. The obtained ytterbium ion concentrations with those of the Al and P elements, determined from EMPA, are compiled in Table 1. We would like to stress that the choice here of aluminophosphosilicate and aluminosilicate glasses was related to their belonging to two families of silicate glasses, in which their compositions are commonly used in active optical fiber fabrication. Moreover, an optimization of these glass compositions for thermometry applications is outside the scope of this work.
Figure 2a shows the luminescence spectra of the YAPS preform, recorded at different temperatures under excitation at 355 nm. Figure 2b displays the PL spectra of YAPS and YAS preforms, with those of their corresponding drawn canes, obtained at 2 K. All these spectra are dominated by a wide visible emission band covering almost the whole visible range. According to the current understanding of the luminescence mechanism of Yb2+ ions, this band is attributed to the 4f5d→4f transitions [4,5]. One can note that, independently on the temperature, the obtained PL band presents a maximum around 582 nm or 502 nm (Figure 2a). Moreover, if, for a preform sample, the PL band presents a maximum around 582 nm and a shoulder around 502 nm, the opposite is true for its corresponding drawn cane (Figure 2b). This result could be attributed to the presence of two main distinct local environments of Yb2+ ions inside the host glass matrix at the origin of the PL around 502 nm and 582 nm. Furthermore, while the overall PL spectral profile does not depend on the composition of the sample, the relative contribution of Yb2+ ions, inside each local environment, to the visible PL spectra is reversed in the drawn cane with respect to its corresponding preform. Either way, regardless of the sample and its composition, the recorded PL spectra remain structured around the two main contributions at about 502 nm and 582 nm. For this reason, thereafter, the PL kinetics were studied at these two emission detection wavelengths (λdet) under excitation at 355 nm (λexc).
In Figure 3a, we presented the results of the PL decay measurements performed on YAS preform at different temperatures in the range from 2 to 300 K. PL kinetics were recorded at 502 nm under excitation at 355 nm. Independently, on the T, all the obtained PL decay curves do not follow a pure mono-exponential function. Nevertheless, they could be successfully fitted by a stretched exponential function that reflects the multisite environment of the Yb2+ ions [16,17]:
I ( t ) = y 0 + A exp t τ β
where I(t) is the luminescence intensity, t is time, y0 is the background (noise level), A is the intensity at t = 0, β is the stretch factor and τ is a characteristic relaxation time. The decay curve and a fit to the function of Equation (1) are shown as an example for T = 30 K in Figure 3b. The common interpretation of such a stretched exponential behavior refers to the overall relaxation of a glass containing a number of independently relaxing species. Every species decays exponentially with one specific relaxation rate τ [18]. It is known that the presence of a co-dopant such as aluminum or phosphorus enhances the dispersion of rare-earth ions inside the glass matrix [19,20]. It reduces their ability for cluster formation and leads to disordered local environments with a multiplicity of sites available for the rare-earth ions. Hence, as our sample contains Al/P or Al, this could explain the stretched exponential nature of the PL dynamic observed at 502 nm. The obtained τ values, as function of T, are presented in Figure 3c and the corresponding β ones in Figure 3d. If this former parameter remains within the range of 0.67–0.79, τ values start with an increase at very low T before a decrease until RT.
In Figure 4, we presented τ values evolution as a function of the temperature for YAS and YAPS preforms and their corresponding canes obtained at two emission wavelengths (502 and 582 nm) under 355 nm excitation. The trend of this PL lifetime is wavelength-dependent. Indeed, at a 502 nm emission wavelength, the emission lifetime is highly temperature-sensitive in the range of 10–50 K when compared to 582 nm. Moreover, this sensitivity is higher with the YAPS samples compared to the YAS ones. One can also note that, for each kind of glass (YAS or YAPS), similar temperature-dependent features manifest in the preform and its corresponding elongated cane. This behavior attests the preservation of emitting Yb2+ ions in the cane samples after drawing at about 2000 °C.
In addition, we tried to model the observed temperature dependence of luminescence lifetimes. We note here that the two-level model, used in the case of Yb2+-activated crystals [12], could not predict the first increase in the fluorescence lifetime occurring at a very low T below 10 K.
On another note, our samples show a global trend of τ as function of T similar to the ones observed, firstly, with Cr3+ ions in oxide crystals [21,22] and, more recently, with Mn4+ ions [23]. Indeed, the decay time constant exhibits an initial increase with cooling. Then, it reaches a maximum value, followed by a decrease with further cooling. Based on the energy level diagram of Cr3+ ions in oxide crystals (Figure 5a), a modified two-level model has been also proposed, which enabled an understanding of their fluorescence lifetime dependences versus T [21,22]. The evolution of the fluorescence lifetime versus temperature, with the maximum at low temperatures, was explained assuming different radiative transition probabilities from the split levels E ¯ and 2 A ¯ (Figure 5a). The probability of radiative decay from the upper level 2 A ¯ is lower compared to that of E ¯ . This induces an increase in the measured radiative decay time of the R-lines emission. Nevertheless, a decrease in the temperature leads to depopulation of the upper level 2 A ¯ . This results in the reduction of its contribution to the emission process in favor of transitions from the low-lying level E ¯ , with a higher radiative decay rate. Thereafter, this provokes a decrease in the measured R-lines emission decay time with further cooling. The modified two-level model includes the main processes affecting the population and radiative rates of the 2E state, namely thermalization, phonon-assisted interactions with lattice vibrations and thermally induced depopulation. According to this model [22], the fluorescence lifetime τ is given by Equation (2):
τ   ( T ) = i = 1 3 g i exp Δ E i k T i = 1 3 g i R i exp Δ E i k T
where Ri are the radiative decay rates, gi are degeneracies of the states, ΔEi is the energy difference between the ith state and the lower excited level, k is the Boltzmann constant and T is the absolute temperature.
By considering the phonon-induced interactions, the radiative decay rate of the ith state was expressed by Equation (3):
R i = 1 τ i c o t h E p 2 k T
where τi is the radiative decay time constant, and Ep stands for “effective energy” of the phonons responsible for the exchange with the sidebands [22].
In addition, both Yb2+ and Cr3+ ions have comparable energy level structures (Figure 5b). Indeed, in an Oh-symmetric environment, the Yb2+ ions have 1A1g, 3T2/3Eu and 1T1u as the ground state, the first excited split levels and the second excited level, respectively [24]. This similarity has prompted the consideration of Equation (2) in fitting the results obtained with our Yb2+-doped samples. In the case of Yb2+, the integers i = 1, 2 and 3 correspond to the 3T2, 3Eu and 1T1u levels with degeneracy equal to 9, 6 and 3, respectively. Subsequently, ΔE1 = 0, ΔE2 = D, the energy split of the 3T2/3Eu levels and ΔE3 = ΔE is the gap between the 3Eu and 1T1u levels. We also introduced two simplifications, as for Cr3+ in [22]. In the first one, we assumed the use of the same value of the phonon energy Ep for the 3T2 and 3Eu levels due to their proximity. In the second one, we omitted the phonon-induced interaction for the radiative decay transitions occurring from the level 1T1u. Thus, the expression for τ (T) can be rearranged as follows:
τ   T = 1 + 2 3 exp D k T + 1 3 exp Δ E k T 1 τ 1 c o t h E p 2 k T + 2 3 τ 2 c o t h E p 2 k T e x p D k T + 1 3 τ 3 exp Δ E k T
In this case, τ1, τ2 and τ3 are the radiative decay times of the 3T2, 3Eu and 1T1u levels, respectively.
Equation (4) was then used to fit the experimental data. As shown for the example of YAS sample in Figure 6, Equation (4) (red curve) fits well the experimental temperature dependence of the decay time. It indicates that the modified two-level model successfully explains the behavior of the Yb2+ ion fluorescence lifetime evolution over the entire investigated temperature range. Moreover, the use of the equation, deduced from the two-level model reported in [12,21] and expressing the fluorescence lifetime as a function of temperature, did not allow a good fit of the experimental data in the decreasing zone after 10 K (the dashed black curve in Figure 6).
The obtained fit parameters, using the modified two-level model, of the Yb2+-doped samples are summarized in Table 2.
From Table 2, we note that, regardless of the sample nature (preform or cane) and λdet, the D value is very low compared to the ΔE one. This shows that the energy gaps between the split levels of Yb2+ ions (3T2 and 3Eu) are weak compared to the one separating the first and third excited states (3T2 and 1T1u). Furthermore, for all the samples, the obtained Ep phonon energy was in the 19–40 cm−1 range. This indicates the involvement of low-energy phonons in Yb2+ ion–phonon coupling in our samples. These Ep values are located in the low-frequency region dominated by the boson peak (BP), a feature characteristic of the glass medium-range order [25,26]. The BP was interpreted as reflecting the acoustic vibration of cohesive domains [27]. Such vibrations could be involved in the phonon coupling with Yb2+ ions in our samples. Concerning the radiative decay times, we obtained τ3 < τ1 < τ2 for all the samples. τ1 < τ2 agrees with the reasoning underlying the interpretation of the observed change in the luminescence decay time constant at low temperatures. On the other hand, τ3 < τ1 and τ2 is consistent with the evolution of the fluorescence lifetime at high temperatures. We would like to stress here that a refined understanding of the obtained parameter values in association with the sample nature (preform or cane), glass composition or λdet deserves further investigation, which is outside the scope of the present study.
From a practical standpoint, our Yb2+-doped samples exhibit a lifetime evolution versus T, with a maximum around 10 K. In contrast, for other materials such as Cr-doped crystals [22], this maximum was found at higher temperatures. In our case, the temperature dependency is more suitable for thermometric applications. Indeed, a temperature dependence, with the maximum at higher temperatures, will cause an indistinctness of the temperature reading and thus limits the operating cryogenic range of the sensor. From the experimental results (Figure 2), we estimated the operating cryogenic ranges of our samples. In these ranges for each temperature corresponds one luminescence lifetime τ value. As depicted in Table 3, independently of the emission detection wavelength, the YAPS samples present larger temperature operating ranges when compared to the ones of YAS composition. For further comparison, related to the performances of our samples for thermometry, we calculated the absolute and relative sensitivity, Sa and Sr, using Equations (5) and (6), respectively. These parameters are defined as follows [28]:
S a = 𝜕 τ 𝜕 T
S r = 1 τ 𝜕 τ 𝜕 T × 100 %
In Table 3 are also summarized the obtained values of Sa and Sr at three different temperatures.
As can be seen from Table 3, both Sa and Sr values decrease with the temperature for all the samples. We also note that, for a given glass composition, YAS or YAPS, the calculated parameters are rather more dependent on the emission wavelength than on the drawing of the preform on a cane. Moreover, regardless of the temperature, the sample and its composition, the Sa and Sr values obtained at a 502 nm emission wavelength are higher compared to the ones at 582 nm. At 502 nm, the composition that stands out is YAPS. It shows a larger temperature operating range of 10–300 K and 15–300 K for the corresponding preform and cane, respectively. Furthermore, both of them also present the highest sensitivities, exceeding the values of 28.3 µsK−1 and 94.4% K−1 at 30 K for Sa and Sr, respectively. Our samples exhibit a comparable sensitivity to Yb2+ ions in fluorite-type crystals [13] and a higher one compared to Cr3+-doped Ga2O3 or Mn4+-activated Li2TiO3 [22,28]. With respect to these three phosphors, they present a wider T-sensing operating range. We also note that the thermometry performances of each preform and its corresponding cane were maintained after drawing at 2000 °C, particularly in the case of a YAPS composition with a maximum relative standard deviation of about 1% for both Sa and Sr at 30 K.

4. Conclusions

We fabricated two kinds of Yb2+-doped preforms, with aluminosilicate and aluminophosphosilicate core glasses, using the MCVD technique under reducing conditions. These preforms were then elongated, at about 2000 °C, to canes with an Yb2+-doped core of about 500 µm.
Under UV excitation, all samples presented a wide visible emission band attributed to Yb2+ ions. The PL kinetics measurements, recorded at two emission wavelengths (502 and 582 nm) under 355 nm pulsed excitation, showed an increase at very low T, followed by a decrease in the lifetime until room T. We extended the modified two-level model to explain the fluorescence lifetime evolution as a function of the temperature. The validity of this model was demonstrated through its close fit to the obtained lifetime data, which also gave access to the expressions of τ as a function of T for each Yb2+-doped sample. Based on these expressions, we calculated the absolute and relative sensitivities of each sample. They were dependent on the emission wavelength, with higher performances at 502 nm. The aluminophosphosilicate glass composition presented the highest sensitivities in the cryogenic domain and the wider T operating range. Furthermore, after drawing, the optical activity of the Yb2+ ions in the visible range and thermometric performances were preserved in the cane samples. Moreover, compared to Yb2+ ions in fluorite-type crystals, our samples present a wider T-sensing operating range.
In addition, both Yb2+ and Yb3+ ions coexist in our YAPS and YAS samples. Although it remains to be determined whether the presence of Yb3+ ions has an impact on the thermal behavior of the Yb2+ luminescence decay time in these samples, from a practical point of view, the presence of trivalent ions (Yb3+) would be an asset that can be exploited for high-temperature thermometry. Hence, this will pave the way for efficient T sensing with both Yb2+/Yb3+-activated glasses in wider T operating ranges, starting from cryogenic temperatures to those beyond 300 K.

Author Contributions

Conceptualization, H.E.H. and M.B.; methodology, H.E.H., I.R., M.C.-B., A.C. and M.B.; software, H.E.H.; validation, H.E.H., I.R., M.C.-B., A.C. and M.B.; formal analysis, H.E.H.; investigation, H.E.H., I.R., M.C.-B., A.C. and V.A.; resources, H.E.H., M.C.-B., A.C. and V.A.; data curation, H.E.H., I.R. and M.C.-B.; writing—original draft preparation, H.E.H.; writing—review and editing, H.E.H., I.R., M.C.-B. and M.B.; visualization, H.E.H. and I.R.; supervision, H.E.H. and M.B.; project administration, H.E.H. and M.B.; funding acquisition, M.B. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported, in part, by the Agence Nationale de la Recherche through the project LABEX CEMPI (ANR-11-LABX-0007). This work was also carried out within the framework of the Contrat de Plan Etat-Region (CPER) WaveTech, which is supported by the Ministry of Higher Education and Research, the Hauts-de-France (HdF) Regional council, the Lille European Metropolis (MEL), the Institute of Physics of the French National Centre for Scientific Research (CNRS) and the European Regional Development Fund (ERDF).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author. The data are not publicly available due to privacy restrictions.

Acknowledgments

This work was supported by the IRCICA Institute and the FiberTech Lille platform of the University of Lille.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Pask, H.M.; Carman, R.J.; Hanna, D.C.; Tropper, A.C.; Mackechnie, C.J.; Barber, P.R.; Dawes, J.M. Ytterbium-doped silica fiber lasers: Versatile sources for the 1–1.2 µm region. IEEE J. Sel. Top. Quantum Electron. 1995, 1, 2–13. [Google Scholar] [CrossRef]
  2. Jauregui, C.; Limpert, J.; Tünnermann, A. High-power fibre lasers. Nat. Photonics 2013, 7, 861–867. [Google Scholar] [CrossRef]
  3. Zervas, M.N.; Codemard, C.A. High Power Fiber Lasers: A Review. IEEE J. Sel. Top. Quantum Electron. 2014, 20, 219–241. [Google Scholar] [CrossRef]
  4. Kirchhof, J.; Unger, S.; Schwuchow, A.; Grimm, S.; Reichel, V. Materials for high-power fiber lasers. J. Non-Cryst. Solids 2006, 352, 2399–2403. [Google Scholar] [CrossRef]
  5. Rydberg, S.; Engholm, M. Experimental evidence for the formation of divalent ytterbium in the photodarkening process of Yb-doped fiber lasers. Opt. Express 2013, 21, 6681–6688. [Google Scholar] [CrossRef]
  6. Shen, Y.; Sheng, Q.; Liu, S.; Li, W.; Chen, D. Effect of aluminum co-doping on the formation of Yb2+ in Ytterbium-doped high silica glass. Chin. Opt. Lett. 2013, 11, 051601. [Google Scholar] [CrossRef]
  7. Xia, C.; Zhou, G.; Han, Y.; Zhao, X.; Hou, L. Luminescence of Yb2+, Yb3+ co-doped silica glass for white light source. Opt. Mater. 2012, 34, 769–771. [Google Scholar] [CrossRef]
  8. McSherry, M.; Fitzpatrick, C.; Lewis, E. Review of luminescent based fibre optic temperature sensors. Sens. Rev. 2005, 25, 56–62. [Google Scholar] [CrossRef]
  9. Collins, S.F.; Baxter, G.W.; Wade, S.A.; Sun, T.; Grattan, K.T.V.; Zhang, Z.Y.; Palmer, A.W. Comparison of fluorescence-based temperature sensor schemes: Theoretical analysis and experimental validation. J. Appl. Phys. 1998, 84, 4649–4654. [Google Scholar] [CrossRef]
  10. Sun, T.; Zhang, Z.Y.; Grattam, K.T.V.; Paimer, A.W. Ytterbium-based fluorescence decay time fiber optic temperature sensor systems. Rev. Sci. Instrum. 1998, 69, 4179–4185. [Google Scholar] [CrossRef]
  11. Topper, B.; Neumann, A.; Albrecht, A.R.; Flores, A.S.; Kuhn, S.; Häßner, D.; Hein, S.; Hupel, C.; Nold, J.; Haarlammert, N.; et al. Potential of ytterbium doped silica glass for solid-state optical refrigeration to below 200 K. Opt. Express 2023, 31, 3122–3133. [Google Scholar] [CrossRef] [PubMed]
  12. Moine, B.; Courtois, C.; Pedrini, C. Luminescence and photoionization processes of Yb2+ in CaF2, SrF2 and BaF2. J. Phys. 1989, 50, 2105–2119. [Google Scholar] [CrossRef]
  13. Bertrand, S.; Jalocha, A.; Tribillon, G.; Bouazaoui, M.; Rouhet, J. Optical fibre temperature sensor in the cryogenic range. Opt. Laser Technol. 1996, 28, 363–366. [Google Scholar] [CrossRef]
  14. Unger, S.; Schwuchow, A.; Dellith, J.; Kirchhof, J. Optical properties of ytterbium/aluminium doped silica glasses. Opt. Mater. Express 2020, 10, 907–925. [Google Scholar] [CrossRef]
  15. Jetschke, S.; Unger, S.; Schwuchow, A.; Leich, M.; Kirchhof, J. Efficient Yb laser fibers with low photodarkening by optimization of the core composition. Opt. Express 2008, 16, 15540–15545. [Google Scholar] [CrossRef] [PubMed]
  16. Cardona, M.; Chamberlin, R.V.; Marx, W. The history of the stretched exponential function. Ann. Phys. 2007, 16, 842–845. [Google Scholar] [CrossRef]
  17. Berberan-Santos, M.; Bodunov, E.; Valeur, B. History of the Kohlrausch (stretched exponential) function: Pioneering work in luminescence. Ann. Phys. 2008, 17, 460–461. [Google Scholar] [CrossRef]
  18. Johnston, D.C. Stretched exponential relaxation arising from a continuous sum of exponential decays. Phys. Rev. B 2006, 74, 184430. [Google Scholar] [CrossRef]
  19. Arai, K.; Namikawa, H.; Kumata, K.; Honda, T.; Ishii, Y.; Handa, T. Aluminum or phosphorus co-doping effects on the fluorescence and structural properties of neodymium-doped silica glass. J. Appl. Phys. 1986, 59, 3430–3436. [Google Scholar] [CrossRef]
  20. Deschamps, T.; Ollier, N.; Vezin, H.; Gonnet, C. Clusters dissolution of Yb3+ in codoped SiO2-Al2O3-P2O5 glass fiber and its relevance to photodarkening. J. Chem. Phys. 2012, 136, 014503. [Google Scholar] [CrossRef]
  21. Zhang, Z.; Grattan, K.T.V.; Palmer, A.W. Temperature dependences of fluorescence lifetimes in Cr3+-doped insulating crystals. Phys. Rev. B 1993, 48, 7772–7778. [Google Scholar] [CrossRef] [PubMed]
  22. Mykhaylyk, V.; Kraus, H.; Zhydachevskyy, Y.; Tsiumra, V.; Luchechko, A.; Wagner, A.; Suchocki, A. Multimodal Non-Contact Luminescence Thermometry with Cr-Doped Oxides. Sensors 2020, 20, 5259. [Google Scholar] [CrossRef] [PubMed]
  23. Mykhaylyk, V.; Kraus, H.; Bulyk, L.-I.; Lutsyuk, I.; Hreb, V.; Vasylechko, L.; Zhydachevskyy, Y.; Luchechko, A.; Wagner, A.; Suchocki, A. Al2O3 co-doped with Cr3+ and Mn4+, a dual-emitter probe for multimodal non-contact luminescence thermometry. Dalton Trans. 2021, 50, 14820. [Google Scholar] [CrossRef] [PubMed]
  24. Suta, M.; Urland, W.; Daul, C.; Wickleder, C. Photoluminescence properties of Yb2+ ions doped in the perovskites CsCaX3 and CsSrX3 (X = Cl, Br, and I)—A comparative study. Phys. Chem. Chem. Phys. 2016, 18, 13196–13208. [Google Scholar] [CrossRef]
  25. Ando, M.F.; Benzine, O.; Pan, Z.; Garden, J.-L.; Wondraczek, K.; Grimm, S.; Schuster, K.; Wondraczek, L. Boson peak, heterogeneity and intermediate-range order in binary SiO2-Al2O3 glasses. Sci. Rep. 2018, 8, 5394. [Google Scholar] [CrossRef]
  26. El Hamzaoui, H.; Bouazaoui, M.; Capoen, B. Raman investigation of germanium- and phosphorus-doping effects on the structure of sol–gel silica-based optical fiber preforms. J. Mol. Struct. 2015, 1099, 77–82. [Google Scholar] [CrossRef]
  27. Duval, E.; Boukenter, A.; Achibat, T. Vibrational dynamics and the structure of glasses. J. Phys. Condens. Matter 1990, 2, 10227–10234. [Google Scholar] [CrossRef]
  28. Dramićanin, M.D. Trends in luminescence thermometry. J. Appl. Phys. 2020, 128, 040902. [Google Scholar] [CrossRef]
Figure 1. (a) UV–Visible and (b) NIR optical absorption spectra of YAPS and YAS preforms.
Figure 1. (a) UV–Visible and (b) NIR optical absorption spectra of YAPS and YAS preforms.
Sensors 24 00248 g001
Figure 2. PL spectra, under 355 nm pulsed excitation, of (a) YAPS preform measured at different temperatures and (b) YAPS and YAS preforms with those of their corresponding canes recorded at 2 K. The PL spectra were obtained by the time integration of the time-resolved ones.
Figure 2. PL spectra, under 355 nm pulsed excitation, of (a) YAPS preform measured at different temperatures and (b) YAPS and YAS preforms with those of their corresponding canes recorded at 2 K. The PL spectra were obtained by the time integration of the time-resolved ones.
Sensors 24 00248 g002
Figure 3. (a) PL kinetics recorded at 502 nm, under excitation at 355 nm, of YAS preform for different temperatures. (b) PL decay curve at 30 K and its corresponding curve fitting analysis using Equation (1). The obtained τ (c) and β (d) values are a function of the temperature.
Figure 3. (a) PL kinetics recorded at 502 nm, under excitation at 355 nm, of YAS preform for different temperatures. (b) PL decay curve at 30 K and its corresponding curve fitting analysis using Equation (1). The obtained τ (c) and β (d) values are a function of the temperature.
Sensors 24 00248 g003
Figure 4. τ values as function of the temperature for YAS and YAPS preforms and their corresponding elongated canes, obtained at 502 and 582 nm emission wavelengths under 355 nm.
Figure 4. τ values as function of the temperature for YAS and YAPS preforms and their corresponding elongated canes, obtained at 502 and 582 nm emission wavelengths under 355 nm.
Sensors 24 00248 g004
Figure 5. Simplified energy level diagrams of (a) Cr3+ ions in oxide crystals and (b) Yb2+ ions in octahedral symmetry (Oh) sites adapted from [22,24], respectively. Colored vertical arrows show excitation (in green) and emission (in red) transitions.
Figure 5. Simplified energy level diagrams of (a) Cr3+ ions in oxide crystals and (b) Yb2+ ions in octahedral symmetry (Oh) sites adapted from [22,24], respectively. Colored vertical arrows show excitation (in green) and emission (in red) transitions.
Sensors 24 00248 g005
Figure 6. Fitting curves to the experimental results of τ as function of T in the case of the YAS preform using the equation related to the two-level model reported in [12,21] and Equation (4) associated with the modified two-level model.
Figure 6. Fitting curves to the experimental results of τ as function of T in the case of the YAS preform using the equation related to the two-level model reported in [12,21] and Equation (4) associated with the modified two-level model.
Sensors 24 00248 g006
Table 1. Estimated mean concentrations of Yb2+/Yb3+ ions and those of the Al and P elements, determined using EPMA, inside the fabricated preforms.
Table 1. Estimated mean concentrations of Yb2+/Yb3+ ions and those of the Al and P elements, determined using EPMA, inside the fabricated preforms.
Sample(Yb2+) (cm−3)(Yb3+) (cm−3)(Al) (at.%)(P) (at.%)
YAS preform8 × 10191.4 × 10201.78-
YAPS preform1 × 10191.9 × 10190.620.23
Table 2. Fit parameters obtained from the temperature dependence of the luminescence decay time using Equation (4) for all samples.
Table 2. Fit parameters obtained from the temperature dependence of the luminescence decay time using Equation (4) for all samples.
Sampleλdet (nm)τ1 (µs)D (cm−1)ΔE (cm−1)Ep (cm−1)τ2 (ms)τ3 (µs)
YAS preform5021090 4.561632.0950.9
YAS cane50213406.676423.6670.5
YAS preform582877 20.267744.1671.1
YAS cane58290921.571239.3831.1
YAPS preform502175010.457419.4671.5
YAPS cane50219208.856021.5951.3
YAPS preform582118020.954134.9672.4
YAPS cane582118019.553035.1832.2
Table 3. Temperature operating ranges and calculated Sa and Sr values at different T using Equation (6) for all samples.
Table 3. Temperature operating ranges and calculated Sa and Sr values at different T using Equation (6) for all samples.
Sampleλdet (nm)T Operating Range Sa (µs K−1) @30 K Sa (µsK−1) @70 KSa (µsK−1) @300 KSr (%K−1) @30 KSr (%K−1) @70 KSr (%K−1) @300 K
YAS preform50230–300 K22.227.120.3874.0910.170.12
YAS cane50220–300 K24.006.490.4580.009.280.15
YAS preform58225–300 K 9.325.730.5031.068.190.16
YAS cane58220–300 K10.645.390.4935.487.710.16
YAPS preform50210–300 K28.327.450.4194.4210.650.13
YAPS cane50215–300 K28.377.670.3894.5910.960.12
YAPS preform58215–300 K15.356.640.4651.169.480.15
YAPS cane58220–300 K15.586.790.4351.949.710.14
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

El Hamzaoui, H.; Razdobreev, I.; Cieslikiewicz-Bouet, M.; Cassez, A.; Andrieux, V.; Bouazaoui, M. Yb2+-Doped Silicate Glasses as Optical Sensor Materials for Cryogenic Thermometry. Sensors 2024, 24, 248. https://doi.org/10.3390/s24010248

AMA Style

El Hamzaoui H, Razdobreev I, Cieslikiewicz-Bouet M, Cassez A, Andrieux V, Bouazaoui M. Yb2+-Doped Silicate Glasses as Optical Sensor Materials for Cryogenic Thermometry. Sensors. 2024; 24(1):248. https://doi.org/10.3390/s24010248

Chicago/Turabian Style

El Hamzaoui, Hicham, Igor Razdobreev, Monika Cieslikiewicz-Bouet, Andy Cassez, Vincent Andrieux, and Mohamed Bouazaoui. 2024. "Yb2+-Doped Silicate Glasses as Optical Sensor Materials for Cryogenic Thermometry" Sensors 24, no. 1: 248. https://doi.org/10.3390/s24010248

APA Style

El Hamzaoui, H., Razdobreev, I., Cieslikiewicz-Bouet, M., Cassez, A., Andrieux, V., & Bouazaoui, M. (2024). Yb2+-Doped Silicate Glasses as Optical Sensor Materials for Cryogenic Thermometry. Sensors, 24(1), 248. https://doi.org/10.3390/s24010248

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop