1. Introduction
The health impacts of exposure to fire-related smoke pollution are well established. These include increases in asthma incidence, use of rescue medication, hospitalisations and emergency department visits. Fire-related smoke pollution also exacerbates and causes cardiovascular disease, and can result in increased mortality [
1,
2,
3]. Around one-third of the Australian population is at elevated risk of developing smoke-associated illnesses during extreme smoke events [
2]. These include individuals with respiratory and cardiovascular diseases, the very young, and older adults [
2]. Particulate matter (PM) is the component of smoke most strongly and consistently linked with adverse health effects [
4,
5].
Standard recommendations to reduce exposure to smoke include the following: avoiding strenuous outdoor exercise, staying indoors with the doors and windows closed, using the air conditioning, and considering visiting an air conditioned public facility [
6,
7]. However, this advice is based on limited evidence of effectiveness for reducing personal exposure to air pollution [
8].
A substantial fraction of outdoor air pollution makes its way indoors. In fact, most exposure to outdoor-generated fine particulate matter (PM
2.5) occurs indoors and most of the health impacts from outdoor-generated PM
2.5 are attributable to exposure that occurs while indoors [
9,
10]. Exposures that occur indoors account for 61% and 81% of the deaths attributed to outdoor-generated PM
2.5 in the USA and China, respectively [
11,
12].
The infiltration efficiency of outdoor air pollution (
Finf) is defined as the fraction of the outdoor PM
2.5 concentration that penetrates indoors and remains suspended under steady-state conditions.
Finf depends on the particle penetration efficiency, the air exchange rate, and the deposition rate. Methods to reduce building infiltration efficiency include closing windows and doors and filtering the air [
9,
13].
One of the most promising indoor defenses against outdoor smoke is the use of portable high efficiency particulate air (HEPA) filters, either in the building’s heating, ventilation, and air conditioning (HVAC) system or in portable air cleaner units. HEPA filters capture ≥ 99.97% of 0.3 µm particles. In previous studies, HEPA cleaners reduced residential PM
2.5 concentrations by 52–67% when used for between 2–3 days and up to 2 weeks in US and Canadian communities impacted by woodsmoke [
13,
14,
15,
16]. Some public health agencies in North America recommend use of portable air cleaners to mitigate the impacts of forest fire smoke in residential settings [
4].
The efficacy of portable air cleaners in larger public spaces has yet to be fully evaluated. Public spaces are increasingly being considered for providing access to “cleaner indoor air spaces” during smoke-related episodes [
17,
18]. However, more information is needed about the protection afforded by air-conditioned spaces and the potential for portable air cleaners to provide additional protection.
The Lindfield Park Road bushfire in Port Macquarie, New South Wales, Australia was one of the fires that heralded the beginning of Australia’s most extreme and prolonged bushfire and air pollution crisis on record. The fire began in mid-winter (July 2019) and moved into peat and continued to burn until February 2020. This fire, combined with many other bushfires in the area, caused several extreme and prolonged outdoor smoke episodes in the region. Peat fires are rarely extinguished rapidly, and the associated air pollution is likely to be prolonged. The emergency response agencies considered whether specific public buildings should be nominated as places to offer some respite from smoke pollution for the general public. Port Macquarie Hastings Council agreed to allow air quality monitoring stations to be set up both inside and outside the local library to evaluate the effectiveness of the building as a cleaner indoor air space.
The aims of the research were as follows:
- (1)
To evaluate the potential for a public building to serve as a cleaner indoor air shelter during smoke events, and
- (2)
To assess the efficacy of installing HEPA cleaners within a smaller room inside the library area.
2. Materials and Methods
The selection of the Port Macquarie library for assessment as a potential “cleaner indoor air shelter” was made after considering a number of public buildings for a range of factors including the following: access, presence of air-conditioning, access to wifi, sufficient seating for the public, and access to public toilets among other criteria (see
Supplementary Materials Table S1 for the checklist tool which was developed specifically for this occasion).
We measured PM2.5 concentrations at the Port Macquarie library from August 23rd, 2019 until November 29th, 2019 using Smoke Observation Gadgets, (SMOG) developed by the Commonwealth Scientific and Industrial Research Organisation (CSIRO). The low-cost sensors include a Plantower 3003 PM sensor (model PMS3003, Plantower, Beijing, China). The SMOG devices logged PM2.5 concentrations at 1-minute resolution. We deployed pairs of SMOG instruments (i) inside the main library, (ii) in the 22 m2 (3.7 m by 6.0 m) media room within the library, (iii) outside in the courtyard, and (iv) collocated with the NSW Department of Planning Industry and Environment’s Office of Environment and Heritage (DPIE) mobile monitoring station in the town. Explanatory signage was erected next to the indoor SMOGs.
SMOG data were corrected using the calculations generated from collocated units with the DPIE managed 1405-DF TEOM located in town. This unit received regular maintenance during the campaign and provides a self-referencing NIST-traceable true mass measurement through internal collected filters. A 3rd order polynomial fit was applied to the SMOG data and the limit of detection for the SMOG units was 5.5 µg/m
3. Direct comparisons of the two SMOG units at each of the tested locations demonstrated a strong association across the range of PM
2.5 concentrations, see
Supplementary Material Figure S1.
We placed two portable HEPA cleaners (Cli-Mate AP20) (Aquaport Corporation Pty Ltd., Torrensville, SA, Australia) in the library’s media room and operated them on the medium fan setting from 24th August until 16th October 2019. These had a Grade H12 HEPA filter and the capacity to clean 20 m2 rooms with a smoke clean air delivery rate (CADR) of 133 m3/h. The selection of the HEPA cleaners and the space to be cleaned, needs to account for their operational capacity. This, therefore, restricted their use to a smaller room within the main library. The units were returned to have the filters replaced after this date so were not available for the remainder of the data collection period.
Because our primary interest was in quantifying relationships between indoor and outdoor PM2.5 concentrations during high smoke concentration events, we included in our analysis only periods with 24-h mean outdoor PM2.5 concentrations ≥ 20 µg/m3 and hours with valid measurements indoors and outdoors. This left 749 h of data for analysis.
We used these data to quantify concentrations of PM
2.5 outdoors, in the main library, and in the media room where the HEPA cleaners were located. We analyzed separately the periods with and without HEPA cleaners operating. We used a previously published and validated approach to estimate the PM
2.5 Finf into the two indoor spaces [
9,
19,
20]. This approach is based on a recursive form of the mass balance model applied to paired hourly indoor and outdoor concentration measurements, see Equation (1). The model uses censoring algorithms to identify and remove the influence of indoor particle sources.
Equation (1):
where,
Finf is a function of particle penetration efficiency (
P), the particle removal rate due to diffusion or sedimentation (
k), and the air exchange rate (
a) [
9].
This study was approved by the Human Research Ethics Committee at the University of Tasmania (H0015006).
3. Results
Over the five-month study, there was a wide range of hourly outdoor PM
2.5 concentrations (median = 31 µg/m
3, 5th–95th percentile = 2–113 µg/m
3). Outdoor air quality was poorest during bushfires that occurred in November. The 24-h average outdoor PM
2.5 concentration peaked at nearly 600 µg/m
3 on November 15th. Across the whole study period, there were 34 days when 24-h average outdoor air PM
2.5 concentrations exceeded the national standard of 25 µg/m
3; 20 of those exceedances occurred in November. We observed that the indoor concentrations of PM
2.5 in the main library during this time of elevated smoke conditions remained substantially lower than outdoor PM
2.5, with an absolute reduction in 24-average PM
2.5 of 8–10 µg/m
3 being achieved (
Table 1).
The library HVAC system was installed in 2000 and was most recently serviced in June 2019. It used cardboard throwaway pleated filters that were replaced annually (F5, type 1 class A). The HVAC system operated from 8 a.m. to 7 p.m. with a 10% fresh air intake during operation. The library had a vestibule; however, both the vestibule door and the entrance door were automatic sliding doors, so they could be opened at the same time. The prevailing winds varied over the five months of the study.
Outdoor PM
2.5 concentrations were consistently higher than indoor measurements (
Figure 1).
When the HEPA cleaner was off (including the smokiest period in November 2019),
Finf in the main library and media room were 0.31 and 0.32, respectively, meaning that compared to the PM
2.5 concentration outdoors, the concentrations of outdoor-generated PM
2.5 indoors were reduced by nearly 70%. When the portable HEPA filter air cleaners were in use in the media room,
Finf was further reduced to 0.17 (
Table 1), and concentrations in the media room were systematically 34% lower than in the main indoor library area (
Figure 2).
4. Discussion
We found that a large building with a central air conditioning system provided an accessible public space with cleaner indoor air during a prolonged air pollution event associated with landscape fires. Inside the building, the concentration of outdoor-generated PM2.5 was, on average, 70% lower than outside, and the addition of portable HEPA cleaners in a smaller media room provided additional reductions in PM2.5 compared to the PM2.5 concentration in the main library.
Our results are consistent with a wide range of residential indoor air quality studies that have demonstrated the benefits of operating HEPA cleaners in appropriately sized rooms during periods of elevated outdoor smoke emissions. Reductions in residential indoor PM
2.5 concentrations have ranged from 52 to 67% in US and Canadian communities impacted by woodsmoke [
13,
14,
15,
19,
20]. None, to our knowledge, have tested the efficacy of portable air cleaners for improving the indoor air quality of public buildings.
While most studies have evaluated improvements in air quality from the use of HEPA filtration, several have also evaluated health endpoints related to exposure to landscape fire smoke. For example, studies in Sweden and Canada have found clinically relevant improvements in microvascular function, an important risk factor for cardiovascular disease, associated with the use of HEPA filtration in homes located in areas affected by wood-heater-related air pollution [
21,
22]. These suggest that the provision of cleaner indoor air environments has the potential to protect health.
Our study operated over an extended period of ongoing smoke resulting from a peat fire and bushfires. This allowed us to evaluate a range of elevated outdoor smoke conditions and to assess the efficacy of installing the HEPA cleaners within a smaller room inside the library area. The HEPA cleaners were only deployed for two months due to limited resources. Thus, the air cleaners were not in place during the most extreme smoke concentrations, which occurred in November 2019.
We unexpectedly found that the infiltration efficiency was higher during periods with less outdoor smoke. It could be that doors were sealed more effectively during the more severe pollution periods, as these periods were also associated with widespread community messaging to reduce exposures. It may also be possible that fewer people ventured outside to visit the library during more intense smoke episodes resulting in less frequent door opening at the library.
Some limitations should be acknowledged. We did not have information on the use of the library doors—how often they were opened and closed, and where they were situated with respect to the prevailing winds. While factors such as the HVAC operation remained consistent throughout the study, meteorological conditions which have been identified in other studies to influence Finf would have changed between winter and summer. The influence of these factors on pollution infiltration could not therefore be evaluated in our study. Further, we did not have information about library staff behaviours, so we did not know if these were different during more smoky periods compared with less smoky periods or how this could have influenced indoor air quality. This study also focused only on the PM emissions from the fires and did not account for any gaseous emissions which could also be detrimental to health.
The public health response to episodic air pollution events centres on the provision of public communications advising on actions to reduce exposure to air pollution [
23]. It has been suggested that simple measures such as staying indoors and keeping doors and windows closed can reduce exposures to these events for short periods of time but is less effective over several days or weeks of reduced air quality [
8,
24]. Indeed, improved health outcomes, as distinct from reduced air pollution, have only been demonstrated when indoor air filtration is used in addition to remaining indoors [
8,
21,
23]. With widespread or prolonged air pollution episodes, the creation of cleaner air spaces in indoor environments is potentially a simple and practical means to reduce overall exposure to air pollution, and it offers individuals a location to find some respite from smoke exposures. Because population-level health impacts suggest that there are no lower safe thresholds, all reductions in exposures can be expected to provide health protection, even when outdoor concentrations are not extreme. This is especially true for episodes of pollution that persist for many days or weeks, when options such as remaining indoors or relocating to nonpolluted areas become increasingly impractical [
23,
24,
25]. Guidance to seek shelter in public buildings is available from a range of organisations including US EPA [
7], Health Canada [
18] and British Columbia Centre for Disease Control [
17]. Our results suggest that this option could be a practical and useful addition to the suite of interventions and advice currently provided in Australia and elsewhere. Further evaluation of the potential benefits and feasibility of this approach is warranted.
5. Conclusions
A carefully selected public building may provide a cleaner indoor air shelter during episodes of elevated fire smoke pollution. Further improvements in indoor air quality within a building can be achieved by selecting appropriately sized HEPA cleaners to operate within the building space, or in a smaller room. Provision of such shelters by jurisdictions requires planning and careful evaluation of potential sites to ensure that the most useful sites can be identified in advance and made available in a timely way when needed.
Supplementary Materials
The following are available online at
https://www.mdpi.com/article/10.3390/ijerph18084085/s1, Table S1: Checklist Tool: NCPHU Community Cleaner Air Shelter Practical Assessment Checklist; Figure S1: SMOG precision: Side by Side Comparison of Two Smog Units at Each of the Library Sites.
Author Contributions
Conceptualization, A.J.W., K.L., G.G.M. and F.H.J.; Data curation, C.T.R. and J.P.; Formal analysis, A.J.W., R.W.A., C.T.R. and F.H.J.; Funding acquisition, G.G.M. and F.H.J.; Investigation, K.L.; Methodology, A.J.W., K.L., C.T.R., G.J.W. and F.H.J.; Project administration, A.J.W. and P.J.J.; Software, C.T.R. and F.R.; Supervision, F.H.J.; Validation, C.T.R., J.P. and F.R.; Visualization, R.W.A.; Writing—original draft, A.J.W., R.WA. and F.H.J.; Writing—review & editing, K.L., C.T.R., J.P., G.J.W., P.J.J. and F.R. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the NHMRC Centre for Research Excellence “Centre for Air pollution, energy and health Research” (CAR). G.J.W.’s funding was provided by the New South Wales government through the NSW Bushfire Risk Management Research Hub.
Institutional Review Board Statement
The study was conducted according to the guidelines of the Declaration of Helsinki and approved by the Human Research Ethics Committee of University of Tasmania (protocol code H0015006 and 27 August 2019). North Coast NSW HREC provided approval on 28 August 2019.
Informed Consent Statement
Not applicable.
Data Availability Statement
Not applicable.
Acknowledgments
The authors would like to acknowledge the support provided by the library staff. We would like to thank Paul Corben at Mid North Coast Local Health District for his input to the study conceptualization. We acknowledge technical support from Christopher Lucani, University of Tasmania.
Conflicts of Interest
The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.
References
- Arriagada, N.B.; Palmer, A.J.; Bowman, D.; Morgan, G.G.; Jalaludin, B.B.; Johnston, F.H. Unprecedented smoke-related health burden associated with the 2019–2020 bushfires in eastern Australia. Med. J. Aust. 2020, 213. [Google Scholar] [CrossRef]
- Johnston, F.H. Understanding and managing the health impacts of poor air quality from landscape fires. Med. J. Aust. 2017, 207, 229–230. [Google Scholar] [CrossRef]
- Naeher, L.P.; Brauer, M.; Lipsett, M.; Zelikoff, J.T.; Simpson, C.D.; Koenig, J.Q.; Smith, K.R. Woodsmoke health effects: A review. Inhal. Toxicol. 2007, 19, 67–106. [Google Scholar] [CrossRef]
- Barn, P.K.; Elliott, C.T.; Allen, R.W.; Kosatsky, T.; Rideout, K.; Henderson, S.B. Portable air cleaners should be at the forefront of the public health response to landscape fire smoke. Environ. Health A Glob. Access Sci. Source 2016, 15, 1–8. [Google Scholar] [CrossRef] [Green Version]
- Keywood, M.; Cope, M.; Meyer, C.M.; Iinuma, Y.; Emmerson, K. When smoke comes to town: The impact of biomass burning smoke on air quality. Atmos. Environ. 2015, 121, 13–21. [Google Scholar] [CrossRef]
- Department of Health. Bushfire Smoke and Your Health. Available online: https://www.health.tas.gov.au/publichealth/air/bushfire_smoke (accessed on 18 March 2021).
- United States Environmental Protection Agency. Available online: https://www.epa.gov/pm-pollution/how-smoke-fires-can-affect-your-health (accessed on 18 March 2021).
- Laumbach, R.; Meng, Q.; Kipen, H. What can individuals do to reduce personal health risks from air pollution? J. Thorac. Dis. 2015, 7, 96–107. [Google Scholar] [CrossRef]
- Allen, R.; Larson, T.; Sheppard, L.; Wallace, L.; Liu, L.-J.S. Use of real-time light scattering data to estimate the contribution of infiltrated and indoor-generated particles to indoor air. Environ. Sci. Technol. 2003, 37, 3484–3492. [Google Scholar] [CrossRef] [PubMed]
- MacNeill, M.; Wallace, L.; Kearney, J.; Allen, R.W.; Van Ryswyk, K.; Judek, S.; Xu, X.; Wheeler, A. Factors influencing variability in the infiltration of PM2.5 mass and its components. Atmos. Environ. 2012, 61, 518–532. [Google Scholar] [CrossRef]
- Azimi, P.; Stephens, B. A framework for estimating the US mortality burden of fine particulate matter exposure attributable to indoor and outdoor microenvironments. J. Expo. Sci. Environ. Epidemiol. 2020, 30, 271–284. [Google Scholar] [CrossRef] [Green Version]
- Xiang, J.; Weschler, C.J.; Wang, Q.; Zhang, L.; Mo, J.; Ma, R.; Zhang, J.; Zhang, Y. Reducing indoor levels of “outdoor PM2. 5” in urban China: Impact on mortalities. Environ. Sci. Technol. 2019, 53, 3119–3127. [Google Scholar] [CrossRef] [PubMed]
- Wheeler, A.J.; Gibson, M.D.; MacNeill, M.; Ward, T.J.; Wallace, L.A.; Kuchta, J.; Seaboyer, M.; Dabek-Zlotorzynska, E.; Guernsey, J.R.; Stieb, D.M. Impacts of air cleaners on indoor air quality in residences impacted by wood smoke. Environ. Sci. Technol. 2014, 48, 12157–12163. [Google Scholar] [CrossRef]
- Ward, T.J.; Semmens, E.O.; Weiler, E.; Harrar, S.; Noonan, C.W. Efficacy of interventions targeting household air pollution from residential wood stoves. J. Expo. Sci. Environ. Epidemiol. 2017, 27, 64–71. [Google Scholar] [CrossRef]
- Barn, P.; Larson, T.; Noullett, M.; Kennedy, S.; Copes, R.; Brauer, M. Infiltration of forest fire and residential wood smoke: An evaluation of air cleaner effectiveness. J. Expo. Sci. Environ. Epidemiol. 2008, 18, 503–511. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Hart, J.F.; Ward, T.J.; Spear, T.M.; Rossi, R.J.; Holland, N.N.; Loushin, B.G. Evaluating the effectiveness of a commercial portable air purifier in homes with wood burning stoves: A preliminary study. J. Environ. Public Health 2011, 2011, 324809. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- BC Centre for Disease Control. Evidence Review: Home and Community Clean Air Shelters to Protect Public Health during Wildfire Smoke Events; Authority, P.H.S., Ed.; British Columbia Centre for Disease Control: Vancouver, BC, Canada, 2014. [Google Scholar]
- Health Canada. Guidance for Cleaner Air Spaces during Wildfire Smoke Events; Health Canada: Ottawa, ON, Canada, 2020.
- Kajbafzadeh, M.; Brauer, M.; Karlen, B.; Carlsten, C.; van Eeden, S.; Allen, R.W. The impacts of traffic-related and woodsmoke particulate matter on measures of cardiovascular health: A HEPA filter intervention study. Occup. Environ. Med. 2015, 72, 394–400. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- McNamara, M.L.; Thornburg, J.; Semmens, E.O.; Ward, T.J.; Noonan, C.W. Reducing indoor air pollutants with air filtration units in wood stove homes. Sci. Total. Environ. 2017, 592, 488–494. [Google Scholar] [CrossRef] [PubMed]
- Bräuner, E.V.; Forchhammer, L.; Møller, P.; Barregard, L.; Gunnarsen, L.; Afshari, A.; Wåhlin, P.; Glasius, M.; Dragsted, L.O.; Basu, S.; et al. Indoor Particles Affect Vascular Function in the Aged. Am. J. Respir. Crit. Care Med. 2008, 177, 419–425. [Google Scholar] [CrossRef]
- Allen, R.W.; Carlsten, C.; Karlen, B.; Leckie, S.; van Eeden, S.; Vedal, S.; Wong, I.; Brauer, M. An air filter intervention study of endothelial function among healthy adults in a woodsmoke-impacted community. Am. J. Respir. Crit. Care Med. 2011, 183, 1222–1230. [Google Scholar] [CrossRef]
- Marfori, M.T.; Campbell, S.L.; Garvey, K.; McKeown, S.; Veitch, M.; Wheeler, A.J.; Borchers-Arriagada, N.; Johnston, F.H. Public Health Messaging During Extreme Smoke Events: Are We Hitting the Mark? Front. Public Health 2020, 8. [Google Scholar] [CrossRef]
- Reisen, F.; Powell, J.C.; Dennekamp, M.; Johnston, F.H.; Wheeler, A.J. Is remaining indoors an effective way of reducing exposure to fine particulate matter during biomass burning events? J. Air Waste Manag. Assoc. 2019, 69, 611–622. [Google Scholar] [CrossRef] [PubMed]
- Vardoulakis, S.; Jalaludin, B.B.; Morgan, G.G.; Hanigan, I.C.; Johnston, F.H. Bushfire smoke: Urgent need for a national health protection strategy. Med. J. Aust. 2020, 212, 349–353.e1. [Google Scholar] [CrossRef] [PubMed] [Green Version]
| Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).