Changes in Muscle Oxygen Saturation Measured Using Wireless Near-Infrared Spectroscopy in Resistance Training: A Systematic Review
Abstract
:1. Introduction
2. Materials and Methods
2.1. Registration of Systematic Review
2.2. Search Strategy
2.3. Eligibility Criteria
2.4. Selection Criteria
2.5. Data Extraction
2.6. Procedures for Extracting Graphed Data
2.7. Assessment of Methodological Quality
Items from Modified Downs and Black Checklist | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Reporting | External Validity | Internal Validity | Total Score | Total as a % | |||||||||||||
Author | 1 | 2 | 3 | 5 | 6 | 7 | 10 | 11 | 12 | 14 | 15 | 16 | 18 | 20 | 25 | ||
Alvarez et al., 2020 [29] | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 10 | 63 |
Gómez-Carmona et al., 2020 [15] | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 8 | 50 |
Davis et al., 2020 [14] | 1 | 1 | 1 | 0 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 7 | 44 |
Timon et al., 2020 [30] | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 8 | 50 |
Total for each item | 4 | 4 | 4 | 2 | 4 | 4 | 2 | 0 | 0 | 0 | 0 | 1 | 4 | 4 | 0 | ||
%per each item | 100 | 100 | 100 | 25 | 100 | 100 | 25 | 0 | 0 | 0 | 0 | 13 | 10 | 100 |
- Is the hypothesis/aim/objective of the study clearly described?
- Are the main outcomes to be measured clearly described in the Introduction or Methods section?
- Are the characteristics of the patients included in the study clearly described?
- Are the distributions of principal confounders in each group of subjects to be compared clearly described?
- Are the main findings of the study clearly described?
- Does the study provide estimates of the random variability in the data for the main outcomes?
- Have actual probability values been reported for the main outcomes except where the probability value is less than 001 (i.e., indicating p = 0.043 rather than p < 0.05)
- Were the subjects asked to participate in the study representative of the entire population from which they were recruited?
- Were those subjects who were prepared to participate representative of the entire population from which they were recruited?
- Was an attempt made to blind study subjects to the intervention they have received?
- Was an attempt made to blind those measuring the main outcomes of the intervention?
- If any of the results of the study were based on ‘data dredging’, was this made clear?
- Were the statistical tests used to assess the main outcomes appropriate?
- Were the main outcome measures used accurately (valid and reliable)?
- Was there adequate adjustment for confounding in the analyses from which the main findings were drawn?
3. Results
3.1. Quality Assessment
3.2. Included Studies and Study Characteristics
4. Discussion
Limitations and Strengths
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Acknowledgments
Conflicts of Interest
References
- Mancini, D.M.; Bolinger, L.; Li, H.; Kendrick, K.; Chance, B.; Wilson, J.R. Validation of near-infrared spectroscopy in humans. J. Appl. Physiol. 1994, 77, 2740–2747. [Google Scholar] [CrossRef] [PubMed]
- Stone, K.J.; Fryer, S.M.; Ryan, T.; Stoner, L. The validity and reliability of continuous-wave near-infrared spectroscopy for the assessment of leg blood volume during an orthostatic challenge. Atherosclerosis 2016, 251, 234–239. [Google Scholar] [CrossRef]
- Crum, E.M.; O’Connor, W.J.; Van Loo, L.; Valckx, M.; Stannard, S.R. Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise. Eur. J. Sport Sci. 2017, 17, 1037–1043. [Google Scholar] [CrossRef]
- Farzam, P.; Starkweather, Z.; Franceschini, M.A. Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle. Physiol. Rep. 2018, 6, e13664. [Google Scholar] [CrossRef] [Green Version]
- Feldmann, A.; Schmitz, R.; Erlacher, D. Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: Reliability and validity of the Moxy Monitor. J. Biomed. Opt. 2019, 24, 115001. [Google Scholar] [CrossRef]
- Scholkmann, F.; Scherer-Vrana, A. Comparison of two NIRS tissue oximeters (moxy and nimo) for non-invasive assessment of muscle oxygenation and perfusion. Adv. Exp. Med. Biol. 2020, 1232, 253–259. [Google Scholar]
- Miranda-Fuentes, C.; Guisado-Requena, I.M.; Delgado-Floody, P.; Arias-Poblete, L.; Pérez-Castilla, A.; Jerez-Mayorga, D.; Chirosa-Rios, L.J. Reliability of low-cost near-infrared spectroscopy in the determination of muscular oxygen saturation and hemoglobin concentration during rest, isometric and dynamic strength activity. Int. J. Environ. Res. Public Health 2020, 17, 8824. [Google Scholar] [CrossRef]
- Peikon, E. The future is NIRS: Muscle oxygen saturation as an estimation of the power-duration relationship. Anat. Physiol. Open Access J. 2019, 1, 00166. [Google Scholar]
- Barstow, T.J. Understanding near infrared spectroscopy and its application to skeletal muscle research. Rev. Cores Reprod. Physiol. J. Appl Physiol 2019, 126, 1360–1376. [Google Scholar] [CrossRef] [PubMed]
- Perrey, S.; Ferrari, M. Muscle oximetry in sports science: A systematic review. Sports Med. 2018, 48, 597–616. [Google Scholar] [CrossRef] [PubMed]
- Bopp, C.M.; Townsend, D.K.; Warren, S.; Barstow, T.J. Relationship between brachial artery blood flow and total [hemoglobin+myoglobin] during post-occlusive reactive hyperemia. Microvasc. Res. 2014, 91, 37–43. [Google Scholar] [CrossRef]
- Bastida Castillo, A.; Gómez Carmona, C.; Pino Ortega, J. Efectos del tipo de recuperación sobre la oxigenación muscular durante el ejercicio de sentadilla. Kronos A J. Interdiscip. Synth. 2016, 15, 1–12. [Google Scholar]
- McManus, C.J.; Collison, J.; Cooper, C.E. Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise. J. Biomed. Opt. 2018, 23, 015007. [Google Scholar] [CrossRef] [PubMed]
- Davis, P.R.; Yakel, J.P.; Anderson, D.J.F. Muscle oxygen demands of the vastus lateralis in back and front squats. Int. J. Exerc. Sci. 2020, 13, 734–743. [Google Scholar] [PubMed]
- Gómez-Carmona, C.D.; Bastida-Castillo, A.; Rojas-Valverde, D.; de la Cruz Sánchez, E.; García-Rubio, J.; Ibáñez, S.J.; Pino-Ortega, J. Lower-limb dynamics of muscle oxygen saturation during the back-squat exercise: Effects of training load and effort level. J. Strength Cond. Res. 2020, 34, 1227–1236. [Google Scholar] [CrossRef] [PubMed]
- Azuma, K.; Homma, S.; Kagaya, A. Oxygen supply-consumption balance in the thigh muscles during exhausting knee-extension exercise. J. Biomed. Opt. 2000, 5, 97–101. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Suchomel, T.J.; Nimphius, S.; Stone, M.H. The importance of muscular strength in athletic performance. Sport. Med. 2016, 46, 1419–1449. [Google Scholar] [CrossRef]
- Maestroni, L.; Read, P.; Bishop, C.; Papadopoulos, K.; Suchomel, T.J.; Comfort, P.; Turner, A. The benefits of strength training on musculoskeletal system health: Practical applications for interdisciplinary care. Sport. Med. 2020, 50, 1431–1450. [Google Scholar] [CrossRef] [PubMed]
- El-Kotob, R.; Ponzano, M.; Chaput, J.P.; Janssen, I.; Kho, M.E.; Poitras, V.J.; Ross, R.; Ross-White, A.; Saunders, T.J.; Giangregorio, L.M. Resistance training and health in adults: An overview of systematic reviews. Appl. Physiol. Nutr. Metab. 2020, 45, S165–S179. [Google Scholar] [CrossRef]
- Joyner, M.J.; Casey, D.P. Regulation of increased blood flow (Hyperemia) to muscles during exercise: A hierarchy of competing physiological needs. Physiol. Rev. 2015, 95, 549–601. [Google Scholar] [CrossRef] [Green Version]
- Formenti, D.; Perpetuini, D.; Iodice, P.; Cardone, D.; Michielon, G.; Scurati, R.; Alberti, G.; Merla, A. Effects of knee extension with different speeds of movement on muscle and cerebral oxygenation. PeerJ 2018, 6, e5704. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Halson, S.L. Monitoring training load to understand fatigue in athletes. Sport. Med. 2014, 44, 139–147. [Google Scholar] [CrossRef] [Green Version]
- Thornton, H.R.; Dascombe, B. Developing athlete monitoring systems in team sports: Data analysis and visualization. Artic. Int. J. Sport. Physiol. Perform. 2019, 14, 698–705. [Google Scholar] [CrossRef]
- Moher, D.; Liberati, A.; Tetzlaff, J.; Altman, D.G.; Altman, D.; Antes, G.; Atkins, D.; Barbour, V.; Barrowman, N.; Berlin, J.A.; et al. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. PLoS Med. 2009, 6, e1000097. [Google Scholar] [CrossRef] [Green Version]
- Suchomel, T.J.; Nimphius, S.; Bellon, C.R.; Stone, M.H. The importance of muscular strength: Training considerations. Sport. Med. 2018, 48, 765–785. [Google Scholar] [CrossRef] [PubMed]
- Downs, S.H.; Black, N. The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions. J. Epidemiol. Community Health 1998, 52, 377–384. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Moeyaert, M.; Maggin, D.; Verkuilen, J. Reliability, validity, and usability of data extraction programs for single-case research designs. Behav. Modif. 2016, 40, 874–900. [Google Scholar] [CrossRef]
- Bonetti, L.V.; Hassan, S.A.; Lau, S.T.; Melo, L.T.; Tanaka, T.; Patterson, K.K.; Reid, W.D. Oxyhemoglobin changes in the prefrontal cortex in response to cognitive tasks: A systematic review. Int. J. Neurosci. 2019, 129, 195–203. [Google Scholar] [CrossRef] [PubMed]
- Alvares, T.S.; Oliveira, G.V.D.; Soares, R.; Murias, J.M. Near-infrared spectroscopy-derived total haemoglobin as an indicator of changes in muscle blood flow during exercise-induced hyperaemia. J. Sports Sci. 2020, 38, 751–758. [Google Scholar] [CrossRef] [PubMed]
- Timón, R.; Ponce-González, J.G.; González-Montesinos, J.L.; Olcina, G.; Pérez-Pérez, A.; Castro-Piñero, J. Inertial flywheel resistance training and muscle oxygen saturation. J. Sports Med. Phys. Fitness 2018, 58, 1618–1624. [Google Scholar] [CrossRef] [PubMed]
- Driller, M.; Plews, D.; Borges, N. Wearable near infrared sensor for determining an athlete’s lactate threshold during exercise. NIR News 2016, 27, 8–10. [Google Scholar] [CrossRef]
- Belardinelli, R.; Barstow, T.J.; Porszasz, J.; Wasserman, K. Changes in skeletal muscle oxygenation during incremental exercise measured with near infrared spectroscopy. Modifications de l’ oxygenation du muscle squelettique lors d’ un exercice progressif, mesurees par spectroscopie infrarouge. Eur. J. Appl. Physiol. Occup. Physiol. 1995, 70, 487–492. [Google Scholar] [CrossRef] [PubMed]
- Rodrigo-Carranza, V.; González-Mohíno, F.; Turner, A.P.; Rodriguez-Barbero, S.; González-Ravé, J.M. Using a portable near-infrared spectroscopy device to estimate the second ventilatory threshold. Int. J. Sports Med. 2021. [Google Scholar] [CrossRef]
- Pereira, M.I.R.; Gomes, P.S.C.; Bhambhani, Y.N. A brief review of the use of near infrared spectroscopy with particular interest in resistance exercise. Sport. Med. 2007, 37, 615–624. [Google Scholar] [CrossRef]
- De Villarreal, E.S.S.; Requena, B.; Newton, R.U. Does plyometric training improve strength performance? A meta-analysis. J. Sci. Med. Sport 2010, 13, 513–522. [Google Scholar] [CrossRef] [PubMed]
- Koga, S.; Barstow, T.J.; Okushima, D.; Rossiter, H.B.; Kondo, N.; Ohmae, E.; Poole, D.C. Validation of a high-power, time-resolved, near-infrared spectroscopy system for measurement of superficial and deep muscle deoxygenation during exercise. J. Appl. Physiol. 2015, 118, 1435–1442. [Google Scholar] [CrossRef] [Green Version]
- Miura, H.; McCully, K.; Hong, L.; Nioka, S.; Chance, B. Regional difference of muscle oxygen saturation and blood volume during exercise determined by near infrared imaging device. Jpn. J. Physiol. 2001, 51, 599–606. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Wang, B.; Xu, G.; Tian, Q.; Sun, J.; Sun, B.; Zhang, L.; Luo, Q.-M.; Gong, H. Differences between the vastus lateralis and gastrocnemius lateralis in the assessment ability of breakpoints of muscle oxygenation for aerobic capacity indices during an incremental cycling exercise. J. Sport Sci. Med. 2012, 11, 606–613. [Google Scholar]
- Hug, F.; Laplaud, D.; Lucia, A.; Grelot, L. EMG threshold determination in eight lower limb muscles during cycling exercise: A pilot study. Int. J. Sports Med. 2006, 27, 456–462. [Google Scholar] [CrossRef]
- Wassenaar, E.B.; Van den Brand, J.G.H. Reliability of near-infrared spectroscopy in people with dark skin pigmentation. J. Clin. Monit. Comput. 2005, 19, 195–199. [Google Scholar] [CrossRef] [PubMed]
- Van Beekvelt, M.C.P.; Borghuis, M.S.; Van Engelen, B.G.M.; Wevers, R.A.; Colier, W.N.J.M. Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle. Clin. Sci. 2001, 101, 21–28. [Google Scholar] [CrossRef] [Green Version]
- Hamaoka, T.; McCully, K.K.; Niwayama, M.; Chance, B. The use of muscle near-infrared spectroscopy in sport, health and medical sciences: Recent developments. Philos. Trans. R. Soc. A Math. Phys. Eng. Sci. 2011, 369, 4591–4604. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Hammer, S.M.; Alexander, A.M.; Didier, K.D.; Huckaby, L.M.; Barstow, T.J. Limb blood flow and muscle oxygenation responses during handgrip exercise above vs. below critical force. Microvasc. Res. 2020, 131, 104002. [Google Scholar] [CrossRef]
- Ockhart, C.A.L.; Cott, B.R.R.S.; Hoseby, B.R.T. Acute effects of interset rest duration on physiological and perceptual responses to resistance exercise in hypoxia catriona. J. Strength Cond. Res. 2018, 34, 2241–2249. [Google Scholar] [CrossRef]
- Carey Smith, R.; Rutherford, O.M. The role of metabolites in strength training—I. A comparison of eccentric and concentric contractions. Eur. J. Appl. Physiol. Occup. Physiol. 1995, 71, 332–336. [Google Scholar] [CrossRef]
- Schott, J.; McCully, K.; Rutherford, O.M. The role of metabolites in strength training—II. Short versus long isometric contractions. Eur. J. Appl. Physiol. Occup. Physiol. 1995, 71, 337–341. [Google Scholar] [CrossRef]
- Suga, T.; Okita, K.; Morita, N.; Yokota, T.; Hirabayashi, K.; Horiuchi, M.; Takada, S.; Omokawa, M.; Kinugawa, S.; Tsutsui, H. Dose effect on intramuscular metabolic stress during low-intensity resistance exercise with blood flow restriction. J. Appl. Physiol. 2010, 108, 1563–1567. [Google Scholar] [CrossRef] [Green Version]
- Takada, S.; Okita, K.; Suga, T.; Omokawa, M.; Kadoguchi, T.; Sato, T.; Takahashi, M.; Yokota, T.; Hirabayashi, K.; Morita, N.; et al. Low-intensity exercise can increase muscle mass and strength proportionally to enhanced metabolic stress under ischemic conditions. J. Appl. Physiol. 2012, 113, 199–205. [Google Scholar] [CrossRef] [PubMed] [Green Version]
Search 1 | Search 2 |
---|---|
“muscle strength” OR “resistance training” OR “strength training”. | “near infrared spectroscopy” OR “NIRS” OR “oximetry” OR “muscle oxygenation”. |
Author | Sample Size and Sex (Male/Female) | Age (Mean ± SD) | Weight (kg) | Height (m) | Level or Condition of Physical Activity or Health |
---|---|---|---|---|---|
Alvarez et al., 2020 [29] | 12/NR | NA | NA | NA | Physically-active |
Gómez-Carmona et al., 2020 [15] | 12/NR | 21.63 ± 1.17 | 77.76 ± 8.77 | 1.81 ± 0.08 | Athlete |
Davis et al., 2020 [14] | 6/5 | 23.7 ± 1.4 | NA | NA | Athlete |
Timon et al., 2020 [30] | 12/NR | 21.1 ± 2.1 | 72.2 ± 7.2 | 1.77 ± 3.8 | Healthy |
Authors | Measurement/Instrument to Assess Muscle Strength | Muscle Strength Protocol for NIRS | NIRS Device | Unit of Measurement | NIRS Protocol | SmO2 Pre or Min * (%) | SmO2 Post or Max * (%) | [tHb] Pre or Min * | [tHb] Post or Max * |
---|---|---|---|---|---|---|---|---|---|
Alvarez et al., 2020 [29] | Isokinetic dynamometer/(Humac Norm, CSMi Medical Solutions, Stoughton, MA, USA) | 1 × 6 MVC at slow velocity (SV) (30 * s−1) and 1 × 6 MVC at fast velocity (FV) (180 * s−1), with 30 min rest between sets. | PortaMon | %; μM * s−1 | Over VL (half the distance between the top of the patella and the femur’s trochanter). | 68.07 ± 2.93 (SV); 66.76 ± 3.52 (FV) | 46.09–45.53 ** (SV); 55.00–53.48 * (FV) | 0.85 ± 1.71 (SV); 1.01 ± 1.52 (FV) | −10.93–11.15 ** (SV); 1.05–1.11 * (FV) |
Gómez-Carmona et al., 2020 [15] | 1RM Assessment Through Velocity-Based Estimation/A cable-extension linear velocity transducer (ChronoJump, Barcelona, Spain) | Squat exercise (4 sets of 4–16 rep at 60–75% 1RM and 40–80% of the level of effort | Moxy | % | Over VL (15 cm from the upper edge of the patella) | Range: 77.30–76.34 | Range: 9.50–7.30 | NA | NA |
Davis et al., 2020 [14] | 1 RM | 3 sets of 15 rep at 70% of their 1-RM weight for both back (BS) and front squats (FS) | Moxy | % | Over VL, approximately 94 mm superior to the patella. | 77.9–68.6 (BS), 83.3–67.9 (FS) | 24.7–22.2 (BS), 24.7–22.2 (FS) | NA | NA |
Timon et al., 2020 [30] | 1RM was estimated from a 1–5 RM with Brzycki’s predictive equation. | Two protocols: 3 × 8 barbell squat (BS) with 3 min rest between each series; 3 × 8 bilateral maximum effort rep and 3 min rest between sets of flywheel YoYo® squat (FS) | Moxy | %, g/dL | VL muscle belly, 12 cm above the lateral epicondyle of the right leg | 73.6–75.4 (BS); 76.5–74.7 (FS) | 19.9–20.4 (BS); 12.1–12.2 (FS) | (g/dL) 12.4–12.5 (BS) **; 12.5 (FS) ** | (g/dL) 12.2–12.3 (BS) **; 12.1–12.2 (FS) ** |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Miranda-Fuentes, C.; Chirosa-Ríos, L.J.; Guisado-Requena, I.M.; Delgado-Floody, P.; Jerez-Mayorga, D. Changes in Muscle Oxygen Saturation Measured Using Wireless Near-Infrared Spectroscopy in Resistance Training: A Systematic Review. Int. J. Environ. Res. Public Health 2021, 18, 4293. https://doi.org/10.3390/ijerph18084293
Miranda-Fuentes C, Chirosa-Ríos LJ, Guisado-Requena IM, Delgado-Floody P, Jerez-Mayorga D. Changes in Muscle Oxygen Saturation Measured Using Wireless Near-Infrared Spectroscopy in Resistance Training: A Systematic Review. International Journal of Environmental Research and Public Health. 2021; 18(8):4293. https://doi.org/10.3390/ijerph18084293
Chicago/Turabian StyleMiranda-Fuentes, Claudia, Luis Javier Chirosa-Ríos, Isabel María Guisado-Requena, Pedro Delgado-Floody, and Daniel Jerez-Mayorga. 2021. "Changes in Muscle Oxygen Saturation Measured Using Wireless Near-Infrared Spectroscopy in Resistance Training: A Systematic Review" International Journal of Environmental Research and Public Health 18, no. 8: 4293. https://doi.org/10.3390/ijerph18084293
APA StyleMiranda-Fuentes, C., Chirosa-Ríos, L. J., Guisado-Requena, I. M., Delgado-Floody, P., & Jerez-Mayorga, D. (2021). Changes in Muscle Oxygen Saturation Measured Using Wireless Near-Infrared Spectroscopy in Resistance Training: A Systematic Review. International Journal of Environmental Research and Public Health, 18(8), 4293. https://doi.org/10.3390/ijerph18084293